1 Division 09 FINISHES TABLE OF CONTENTS GENERAL... 3 A. RELATED SECTIONS... 3 B. MAINTENANCE OF FINISHES... 3 C. PUBLIC AREAS... 3 D. CUTTING AND PATCHING... 3 E. CLEANING... 3 F. RECOMMENDED FLOORING BASED ON FUNCTION OF SPACE GYPSUM BOARD TILING... 4 A. PUBLIC RESTROOMS AND SHOWERS... 4 B. DRINKING FOUNTAINS... 4 C. SAFETY SHOWERS AND EYE WASH STATIONS CEILINGS... 4 A. EQUIPMENT COORDINATION... 4 B. NON ACCESSIBLE CEILINGS ACOUSTIC TILE CEILINGS... 4 A. PANELS... 4 B. SUSPENSION SYSTEM WOOD FLOORING RESILIENT BASE AND ACCESSORIES RESILIENT SHEET FLOORING RESILIENT TILE FLOORING TILE CARPETING SHEET CARPETING ACCESS FLOORING of 6

2 WALL COVERINGS WINDOW SILLS EXTERIOR PAINTING INTERIOR PAINTING STAINING AND TRANSPARENT FINISHING of 6

3 Division 09 FINISHES This design standard is directed to the Design Professional to be incorporated into the Project specifications. The Owner encourages improved concept, method and products by the Design Professional; however Project compatibility with existing campus systems, processes and procedures is most desirable GENERAL A. RELATED SECTIONS 1. Division SUSTAINABLE DESIGN REQUIREMENTS 2. Division 33 - UTILITIES B. MAINTENANCE OF FINISHES 1. Where existing floor finishes, need to be protected from undo wear and/or soiling from construction activities, provide detailed specification requirements for protection of floors. 2. Where existing wall finishes, need to be protected from undo wear and/or soiling from construction activities, provide detailed specification requirements for protection of walls. C. PUBLIC AREAS 1. Wall and floor surfaces of public areas such as lobbies, entrance to elevators, corridors and stair towers shall be of a highly durable, no-maintenance finish. 2. Wood surfaces may be considered. 3. Based on wall surface material used corner guards may be necessary on outside corners. If used all corner guard hardware shall be concealed. review and approval is required. 4. Stainless steel corner guards are not preferred. D. CUTTING AND PATCHING 1. Patch areas in a manner that eliminates evidence of patching and refinishing. 2. Refinishing should provide an even surface of uniform finish, color, texture and appearance of all finish. surfaces including as much of the surrounding wall as practical. (i.e. corner to corner most adjacent to the patch) 3. Patch, repair, and/or re-hang ceilings to provide an even plane surface of uniform appearance. 4. Restore exterior building enclosures to a weather-tight condition. 5. Clean all areas and spaces removing debris immediately after work has been completed. E. CLEANING 1. Require pre and post walk through of project site to document conditions. 2. Contractor shall be responsible to get the space to the agreed upon APPA Level of Clean required in the SDSU Contractor Cleaning Standard at substantial completion and maintain it at this level through the completion of the punch list. 3. Protect finished floor appropriately during punch list phase. F. RECOMMENDED FLOORING BASED ON FUNCTION OF SPACE 1. We encourage the use of hard surface flooring in certain spaces. The list includes but is not limited to: vestibules, entrances, corridors, hallways, laboratories, classrooms, faculty offices, student (GTA, GRA) offices, mechanical spaces, custodial spaces, storage rooms, restrooms, changing rooms, locker rooms, food production spaces, resident hall student rooms, and laundry areas. 2. We consider the use of soft surface flooring in certain spaces. The list includes but is not limited to: administrative offices, conference rooms, fine art performance space such as theaters, dining areas, and lounge areas. 3. For spaces not listed above, flooring material types shall be discussed and approved by Facilities and Services. 3 of 6

4 GYPSUM BOARD 1. Do not direct-glue gypsum board to masonry below grade. 2. Use cement board or superior product as backer for ceramic tile installations in wet locations such as restrooms, drinking fountain surrounds and labs TILING A. PUBLIC RESTROOMS AND SHOWERS 1. Wall surface. a. Ceramic or porcelain tile and epoxy grout. b. Install floor to ceiling; in restrooms a minimum 5-0 AFF with epoxy paint above may be considered. 2. Floor surface. a. Slip resistant ceramic tile and epoxy grout. b. Grout color to be reviewed by and approval is required before specifying color, medium to dark colors preferred. c. Use ceramic base and corners. d. Do not use resilient tile or sheet materials. e. If the room has a sloping floor and or a floor drain, evaluate tile sizes and overall design to provide a desirable overall finish. Try to avoid numerous cuts in large tiles, irregulars shapes and enlarged grout lines to compensate for floor slope and or drain. B. DRINKING FOUNTAINS 1. Ceramic tile wall installed to a minimum 5-0 AFF behind drinking fountain. 2. Stainless steel surrounds shall not be used. C. SAFETY SHOWERS AND EYE WASH STATIONS 1. If located in hallways or corridors use ceramic tile 5-0 AFF on walls behind station. 2. Review adjacent walls and propose ceramic tile 5-0 AFF when reasonable CEILINGS A. EQUIPMENT COORDINATION 1. Coordination with mechanical, electrical, and plumbing equipment is required when laying out ceiling grids and supports; no mechanical, electrical or plumbing access should be blocked. 2. A maintenance access zone (vertically and horizontally) is to be defined and called out on drawings and maintained though final construction. 3. Lighting shall not be located in the maintenance access zones or access points. 4. Removal of ceiling tiles may not be blocked by equipment, piping, and conduit. a. A minimum of 8 from the suspended ceiling to the bottom of equipment and ductwork is desired for ceiling tile removal. B. NON ACCESSIBLE CEILINGS 1. Access shall be provided to all equipment above non-accessible ceiling. 2. Minimum 24 x24 access consideration shall be given to the equipment in the space ACOUSTIC TILE CEILINGS A. PANELS 1. 2 x2 preferred maximum size. 2. Not less than 5/8 thick. 4 of 6

5 3. Square cut edges preferred, if revealed edge use tapered edge. B. SUSPENSION SYSTEM 1. 15/16 wide tees preferred. 2. Tile shall be supported on all four edges. <detail> 3. Suspension system shall only support the ceiling tile. a. Lay in fixtures shall be self-supported WOOD FLOORING 1. Wood flooring can be considered for spaces for preforming arts, museums and gymnasiums 2. Wood flooring shall not be considered as typical flooring. review and approval is required for use of any wood flooring RESILIENT BASE AND ACCESSORIES 1. Stair treads of medium to dark color are preferred, light colors shall not be used. review and approval is required before specifying texture and color. 2. Homogeneous resilient base rolled goods preferred over 4 sections RESILIENT SHEET FLOORING 1. review and approval required before specifying any sheet flooring RESILIENT TILE FLOORING 1. Vinyl composition tile is preferred. 2. 1/8 thick with full depth pattern. 3. Refer to Supplemental Design Guide/SDSU Floor Finishing Schedule TILE CARPETING 1. When carpeting is an approved flooring material, carpet tiles are preferred over rolled goods SHEET CARPETING 1. to review and approve before specifying any sheet carpeting ACCESS FLOORING 1. to review and approve before specifying any access flooring systems WALL COVERINGS 1. Wallpaper, vinyl, textile, and woven glass-fiber wall coverings shall not be used as a wall finish in areas such as lobbies, entrance to elevators, corridors and stairs. 2. to review and approve before specifying any wall coverings WINDOW SILLS 5 of 6

6 1. Preferred products include but are not limited to, stone, solid surface and ceramic tile. 2. Wood may be considered. 3. Laminate or any painted surface is not acceptable EXTERIOR PAINTING 1. Specify the most durable and least environmentally damaging paints and coatings available 2. Do not cover or paint any signs, labels, identification, etc. If covered or painted the contractor will be responsible for replacing the items covered or painted INTERIOR PAINTING 1. Specify the most durable and least environmentally damaging paints and coatings available. 2. Do not cover or paint any signs, labels, identification, etc. If covered or painted the contractor will be responsible for replacing items STAINING AND TRANSPARENT FINISHING 1. Seal and stain all edges of wood doors especially top and bottom after trimming to fit. END OF 6 of 6

GENERAL PROVISIONS

GENERAL PROVISIONS 09 00 03 GENERAL PROVISIONS A. For renovation projects, consider the building s character and existing finishes. All material patches should blend as closely as possible. Some buildings on campus have

More information

GENERAL PROVISIONS

GENERAL PROVISIONS 09 00 03 GENERAL PROVISIONS A. For renovation projects, consider the building s character and existing finishes. All material patches should blend as closely as possible. Some buildings on campus have

More information

DESIGN AND CONSTRUCTION STANDARDS November 2010

DESIGN AND CONSTRUCTION STANDARDS November 2010 09 00 03 GENERAL PROVISIONS A. For renovation projects, consider the building s character and existing finishes. All material patches should blend as closely as possible. Some buildings on campus have

More information

DESIGN AND CONSTRUCTION STANDARDS April 2011

DESIGN AND CONSTRUCTION STANDARDS April 2011 09 00 03 GENERAL PROVISIONS A. For renovation projects, consider the building s character and existing finishes. All material patches should blend as closely as possible. Some buildings on campus have

More information

1. Adequate framing details, sizing, spacing and technical information shall be indicated on the documents.

1. Adequate framing details, sizing, spacing and technical information shall be indicated on the documents. DIVISION 9 - FINISHES 09100 - METAL SUPPORT SYSTEMS 1. Adequate framing details, sizing, spacing and technical information shall be indicated on the documents. 2. Fire-rated assemblies and acoustic rating

More information

2. In moist areas, portland cement plaster should be used if a more permanent material is not within budget limits.

2. In moist areas, portland cement plaster should be used if a more permanent material is not within budget limits. UDIVISION 9 FINISHES 09 00 00 FINISHES 09 20 00 PLASTER AND GYPSUM BOARD PLASTER 1. Major partitions are to extend to underside of structure as required by code. Allow for structural deflection. Provide

More information

SECTION GYPSUM BOARD ASSEMBLIES

SECTION GYPSUM BOARD ASSEMBLIES SECTION 09260 GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.1 SUMMARY A. Provide gypsum board assemblies. 1.2 SUBMITTALS A. Product Data: Submit manufacturer's product data and installation instructions for

More information

.2 These guidelines should be read with the specific technical sections of McGill s Building Design and Technical Standards.

.2 These guidelines should be read with the specific technical sections of McGill s Building Design and Technical Standards. Part 1 General 1.1 Summary.1 Unless otherwise indicated, follow the standards below when planning for Corridors and Hallways. These standards are not intended to restrict or replace professional judgment..2

More information

In the design development phase, submit finish and material selections to Facilities Management Planning Group for review.

In the design development phase, submit finish and material selections to Facilities Management Planning Group for review. 09 00 00 FINISHES 09 01 00 Maintenance of Finishes 09 01 20 Maintenance of Plaster and Gypsum Board 09 01 20.91 Plaster Restoration 09 01 30 Maintenance of Tiling 09 01 30.91 Tile Restoration 09 01 50

More information

NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

NOTE: Significant revisions or additions to the previous standards are highlighted in italics. 9 Finishes NOTE: Significant revisions or additions to the previous standards are highlighted in italics. GENERAL Designers shall verify that all applicable portions of these standards are incorporated

More information

Interior finishes include wall finishes, floor finishes, wall base finishes, and ceiling finishes.

Interior finishes include wall finishes, floor finishes, wall base finishes, and ceiling finishes. 6. ENGINEERING SYSTEMS REQUIREMENTS C30 INTERIOR FINISHES SYSTEMS REQUIREMENTS INTERIOR FINISHES TEMPLATE 02/18 Instructions for using this template: There are template files for each UNIFORMAT Level 2

More information

C. Wallboard shall not be glued directly to masonry or concrete walls below grade: provide furring.

C. Wallboard shall not be glued directly to masonry or concrete walls below grade: provide furring. 09 0561 COMMON WORK RESULTS FOR FLOORING PREPARATION 09 0562 REMEDIAL FLOOR COATING 09 2116 - GYPSUM BOARD ASSEMBLIES A. Special consideration shall be given to the noise reduction characteristic and installation

More information

Collins Middle School

Collins Middle School Contents Collins Middle School...2 General comments, campus capacity, and student demographics:...2 1.0 School Site...4 2.0 Building Systems and Components...5 3.0 Building Safety and Security...19 4.0

More information

F.C.L. INTERIOR FINISHES CHECK LIST 2010 PRODUCT SELECTION - FLOORING GENERAL ITEMS PRODUCT SELECTION GENERAL ITEMS

F.C.L. INTERIOR FINISHES CHECK LIST 2010 PRODUCT SELECTION - FLOORING GENERAL ITEMS PRODUCT SELECTION GENERAL ITEMS INTERIOR FINISHES CHECK LIST 2010 Project: Project Number: Wil-Spec # This should not take long to go through, most questions below are listed as options, all you have to do is check off those answers

More information

DIVISION 9 FINISHES. The Consultant shall consider the use of the space and long-term maintenance requirements in the selection of finishes

DIVISION 9 FINISHES. The Consultant shall consider the use of the space and long-term maintenance requirements in the selection of finishes DIVISION 9 FINISHES GENERAL The Consultant shall consider the use of the space and long-term maintenance requirements in the selection of finishes D.C. Building Code and National Fire Protection Association

More information

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent.

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent. SECTION 092900 - GYPSUM BOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS

TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS AIA General Conditions... GC-1 to GC-44 Amendments to General Conditions... AM-1 to AM-2 Supplements to General Conditions... SU-1 to SU-7 00200 Instructions To Bidders... 1 3 00201 Contractor s Bidding

More information

SECTION ALTERATION PROJECT PROCEDURES

SECTION ALTERATION PROJECT PROCEDURES SECTION 013516 ALTERATION PROJECT PROCEDURES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Requirements for protection of existing facilities during construction operations. 2. Demolition and removals

More information

Building Excellence IV Capital Levy Projects Under Construction

Building Excellence IV Capital Levy Projects Under Construction Building Excellence IV Capital Levy Projects Under Construction Project Slide Number Arbor Heights Elementary School 2 Cascadia Elementary School & Robert Eagle Staff Middle School 14 Genesee Hill Elementary

More information

MECHANICAL M-1 LEGEND AND DETAILS M-2 FLOOR PLAN - DUCTWORK M-3 FLOOR PLAN - PIPING

MECHANICAL M-1 LEGEND AND DETAILS M-2 FLOOR PLAN - DUCTWORK M-3 FLOOR PLAN - PIPING SHEET TITLE ARCHITECTURAL A-0 COVER SHEET A-1 DEMOLITION NOTES A-2 DEMOLITION PLAN A-3 FLOOR PLAN NOTES A-4 FLOOR PLAN A-5 INTERIOR ELEVATIONS A-6 DOOR SCHEDULE A-7 DETAILS MECHANICAL M-1 LEGEND AND DETAILS

More information

BUILDING CONDITION: INTERIOR

BUILDING CONDITION: INTERIOR Typical interior finishes at the Main Building consist of VCT flooring, plaster walls, and lay in ceilings at classrooms and instructional spaces Corridors have terrazzo flooring and partial height glazed

More information

SECTION GYPSUM BOARD SYSTEM

SECTION GYPSUM BOARD SYSTEM PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 09 29 00 GYPSUM BOARD SYSTEM A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 specification sections,

More information

CHAPTER 6 INTERIOR CONSTRUCTION

CHAPTER 6 INTERIOR CONSTRUCTION CHAPTER 6 INTERIOR CONSTRUCTION 6-1 This Page Left Intentionally Blank 6-2 CHAPTER 6 INTERIOR CONSTRUCTION Section 6.1 General Design Guidelines 6.1.1 Preferred Wall System for Wet Areas 6.1.2 Stairwells

More information

Evansville Public Schools. Facility Assessment Report January 28, 2 , General Building Data

Evansville Public Schools. Facility Assessment Report January 28, 2 , General Building Data Evansville Public Schools Facility Assessment Report January 28, 2, 2013 SGN/Wendel Architects, Design Tree Engineering and R.A. Morton Construction Managers were retained by the Evansville Public School

More information

The following shall be incorporated into the Contract Documents dated 26 MAR 2018.

The following shall be incorporated into the Contract Documents dated 26 MAR 2018. ADDENDUM NO. 2 DATE: April 12, 2018 PROJECT: OWNER: BID DATE: Munising Public Schools Mather Elementary Renovation Munising Public Schools Friday, April 20, 2018 at 10:00 a.m. The following shall be incorporated

More information

Division 09. Finishes

Division 09. Finishes 09 00 00. Finishes 09 05 00. Common Work Results for Finishes 09 05 05. General Requirements for Finishes 1. It is the goal of the University to use sustainable finishes to the greatest extent possible.

More information

1. Interior gypsum board. 2. Glass-mat gypsum sheathing board for ceilings and soffits. 3. Cement board. 4. Sound attenuation blankets

1. Interior gypsum board. 2. Glass-mat gypsum sheathing board for ceilings and soffits. 3. Cement board. 4. Sound attenuation blankets SECTION 09 29 00 - GYPSUM BOARD PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Interior gypsum board. 2. Glass-mat gypsum sheathing board for ceilings and soffits. 3. Cement board. 4. Sound attenuation

More information

Include a paint or finish schedule on the drawings, listing colors, locations and types of materials.

Include a paint or finish schedule on the drawings, listing colors, locations and types of materials. DIVISION 09 - FINISHES Section 09900 - Painting Introduction This Section applies to exterior and interior areas or surfaces which are intended to receive a final field painted finish. Final painted finishes

More information

Facilities Management Services & Funding Guide Centrally Funded and Recharge Services

Facilities Management Services & Funding Guide Centrally Funded and Recharge Services Facilities Management Services & Funding Guide Centrally Funded and Recharge Services Table of Contents About the Funding Guide Page 3 Carpenter Shop Page 4 Custodial Services Page 5 Electrical Shop Page

More information

SECTION GYPSUM BOARD SYSTEM

SECTION GYPSUM BOARD SYSTEM PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 09 29 00 GYPSUM BOARD SYSTEM A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 specification sections,

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS ************************************************************************** SECTION TABLE OF CONTENTS

UNIFIED FACILITIES GUIDE SPECIFICATIONS ************************************************************************** SECTION TABLE OF CONTENTS USACE / NAVFAC / AFCEC / NASA UFGS-09 06 00 (May 2009) Change 1-11/13 ----------------------------- Preparing Activity: USACE Superseding UFGS-09 06 90 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

PROCUREMENT AND CONTRACTING DOCUMENTS GROUP

PROCUREMENT AND CONTRACTING DOCUMENTS GROUP PROCUREMENT AND CONTRACTING DOCUMENTS GROUP DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS 00 11 00 Notice To Bidders 00 21 00 Instructions To Bidders 00 22 00 Supplementary Instructions To Bidders

More information

TABLE OF CONTENTS Public Safety Building

TABLE OF CONTENTS Public Safety Building DOCUMENT 00 01 10 - TABLE OF CONTENTS VOLUME I DIVISION 00 PROCUREMENT AND CONTRACTING REQUIREMENTS 00 01 10 Table of Contents 00 31 32 Geotechnical Data DIVISION 01 GENERAL REQUIREMENTS 01 10 00 Summary

More information

GENERAL FINISHES REQUIREMENTS

GENERAL FINISHES REQUIREMENTS 09 00 00 GENERAL FINISHES REQUIREMENTS i. 00 00 13 Designing Learning Environments ii. 01 35 46 Indoor Air Quality Procedures During Construction iii. 01 41 26.06 Dining Services iv. 09 30 00 Tiling v.

More information

Corsicana High School

Corsicana High School Contents Corsicana High School...2 General comments, campus capacity, and student demographics...2 1.0 School Site...4 2.0 Building Systems and Components...6 3.0 Building Safety and Security...19 4.0

More information

SECTION GYPSUM BOARD & SHEATHING SYSTEMS

SECTION GYPSUM BOARD & SHEATHING SYSTEMS PART 1!GENERAL! 1.01! SECTION INCLUDES SECTION 09260 GYPSUM BOARD & SHEATHING SYSTEMS! Metal stud wall framing. Metal channel ceiling framing.! Gypsum board.! Sheathing.! Taped and sanded joint treatment.!

More information

AGILITAS Property Development

AGILITAS Property Development Hartmann Commons offered by For Infomation and Leasing Mr. Seth T. McDowell 1614 16th Avenue South Nashville, Tennessee 37212 Voice 615-327-8788 Fax 615-327-8789 Hartmann Commons Agilitas Property Development

More information

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT TABLE OF CONTENTS INTRODUCTORY INFORMATION 00 00 10 Title Page 00 00 20 Table of Contents DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT Section 00 02 00 Notice to Bidders

More information

Al Behrman Elementary School

Al Behrman Elementary School Mulberry Street Al Behrman Elementary School Relocate reception and principal s office to be adjacent to main entrance doors; provide secure entrance sequence and increase transparency to the exterior

More information

Columbia County Health Care Center Added Amenities

Columbia County Health Care Center Added Amenities Columbia County Health Care Center Added Amenities Columbia County Board Meeting on January 16th, 2013 Building Exterior Added Amenities 1. Upgraded nail-base roofing insulation to 3 thickness on Center

More information

Interior finishes include wall finishes, floor finishes, wall base finishes, and ceiling finishes.

Interior finishes include wall finishes, floor finishes, wall base finishes, and ceiling finishes. 6. ENGINEERING SYSTEMS REQUIREMENTS C30 INTERIOR FINISHES SYSTEMS REQUIREMENTS INTERIOR FINISHES TEMPLATE 02/18 Instructions for using this template: There are template files for each UNIFORMAT Level 2

More information

Michael Teller, CBI Consulting Inc. Gymnasium & Auditorium Restoration at South Middle School

Michael Teller, CBI Consulting Inc. Gymnasium & Auditorium Restoration at South Middle School A D D E N D U M # 1 DATE: TO: FROM: PROJECT: All Bidders Michael Teller, CBI Consulting Inc. Gymnasium & Auditorium Restoration at South Middle School CBI JOB NO.: 11063 The following items shall modify

More information

Proposal. Lexington, MA. Price Work Description

Proposal. Lexington, MA. Price Work Description PROPOSAL Assumptions Sample Client Lexington, MA The is based on plans dated 3/3/15, with Sally's list of adjustments The price assumes the owners will be living in the house The owners will be responsible

More information

SECTION TILING

SECTION TILING PART 1 GENERAL 1.01 SECTION INCLUDES A. Ceramic Tile for floor applications. B. Ceramic Tile for wall applications. C. Ceramic accessories. D. Ceramic trim. E. Non-ceramic trim. 1.02 RELATED REQUIREMENTS

More information

DESIGN GUIDELINES AND TECHNICAL STANDARDS

DESIGN GUIDELINES AND TECHNICAL STANDARDS DESIGN GUIDELINES AND TECHNICAL STANDARDS Date of Issuance: January 1, 2014 DIVISION 9 FINISHES SECTION 09 2900 GYPSUM BOARD 1. General: This section outlines the requirements for gypsum board systems.

More information

GENERAL FINISHES REQUIREMENTS

GENERAL FINISHES REQUIREMENTS 09 00 00 GENERAL FINISHES REQUIREMENTS i. 00 00 13 - Designing Learning Environments ii. 01 35 46 Indoor Air Quality Procedures During Construction iii. 09 30 00 Tiling iv. 09 60 00 Flooring v. 09 68 00

More information

A2.0 TRIPLE M DEVELOPMENT EXTERIOR ELEVATIONS. Rochester, MN Hwy 52 North. Apr 07, phone fax

A2.0 TRIPLE M DEVELOPMENT EXTERIOR ELEVATIONS. Rochester, MN Hwy 52 North. Apr 07, phone fax NORTH ELEVATION 1 1/8" = 1'-0" WEST ELEVATION 2 1/8" = 1'-0" SOUTH ELEVATION 3 1/8" = 1'-0" EXTERIOR ELEVATIONS A2.0 EAST ELEVATION 4 1/8" = 1'-0" EXTERIOR FRAME TYPES 1 1/4" = 1'-0" 2 INTERIOR FRAME TYPES

More information

TABLE OF CONTENTS Updated 1/2014 SECTION TITLE DATE

TABLE OF CONTENTS Updated 1/2014 SECTION TITLE DATE TABLE OF CONTENTS SECTION TITLE DATE Division 00 Procurement and Contracting Requirements 000101... Project Title Page 000116... CAD Standards 001116... Invitation to Bid 002113... Instructions to Bidders

More information

UNIVERSITY OF MISSOURI Division 09 - Finishes General Finishes Specification information to be considered by Consultants.

UNIVERSITY OF MISSOURI Division 09 - Finishes General Finishes Specification information to be considered by Consultants. General Finishes Specification information to be considered by Consultants. 1. Finishes and Furnishings such as carpet, wall coverings, furniture and cabinets will comply with "Fire Spread Ratings Requirements"

More information

Subject: Lucretia Mott School No. 3 Rehabilitation. Figure 1 Figure 2 Figure 3

Subject: Lucretia Mott School No. 3 Rehabilitation. Figure 1 Figure 2 Figure 3 MEMORANDUM To: Ashley Rosenthal Payne, Indianapolis Historic Preservation Commission Adrienne Schmetzer, Indiana Housing and Community Development Authority Architecture Preservation Interior Design Landscape

More information

NC State University Design and Construction Guidelines Division 00 Planning & Design Space Planning

NC State University Design and Construction Guidelines Division 00 Planning & Design Space Planning 1.0 Purpose A. These guidelines provide requirements for the Designer and Contractor to follow related to space planning. 2.0 General Requirements A. Single Occupant Toilet Room Each new or renovated building

More information

Interior finishes include wall finishes, floor finishes, wall base finishes, and ceiling finishes.

Interior finishes include wall finishes, floor finishes, wall base finishes, and ceiling finishes. 6. ENGINEERING SYSTEMS REQUIREMENTS C30 INTERIOR FINISHES SYSTEMS REQUIREMENTS INTERIOR FINISHES TEMPLATE 02/18 Instructions for using this template: There are template files for each UNIFORMAT Level 2

More information

SECTION A. Examination, preparation, and general installation procedures.

SECTION A. Examination, preparation, and general installation procedures. SECTION 01 7000 PART 1 GENERAL 1.1 SECTION INCLUDES A. Examination, preparation, and general installation procedures. B. Cutting and patching. C. Cleaning and protection. D. Substantial Completion E. Final

More information

Site Bldg Fiscal Yr System Sub-System. Verde Valley Site site 2014/15 Parking Paving. Verde Valley Site site 2014/15 Sidewalks

Site Bldg Fiscal Yr System Sub-System. Verde Valley Site site 2014/15 Parking Paving. Verde Valley Site site 2014/15 Sidewalks Site Bldg Fiscal Yr System Sub-System Site site 2014/15 Parking Paving Site site 2014/15 Sidewalks Skill Center L 2015/16 Architectural Partitions Site Site 2015/16 Parking Striping Arc Center M 2014/15

More information

SECTION GYPSUM BOARD ASSEMBLIES

SECTION GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 09260 - A. Metal stud wall framing. Denoted on drawings as "metal studs". B. Metal channel ceiling framing. C. Acoustic insulation and sealant. D. Cementitious

More information

Facility Assessment Report, Montgomery Independent School District

Facility Assessment Report, Montgomery Independent School District NATATORIUM CAMPUS DATA NATATORIUM 22628 Hwy 105 West, Montgomery TX 77356 Year Built 2009 Approx. Total Square Footage Grades Served 30,420 n/a Current Enrollment n/a Building Levels 1 1 MASTER PLAN 2

More information

DALLAS-FORT WORTH INTERNATIONAL AIRPORT

DALLAS-FORT WORTH INTERNATIONAL AIRPORT DALLAS-FORT WORTH INTERNATIONAL AIRPORT ADDENDUM NO. 2 TO THE REQUEST FOR BIDS Contract No. 9500445 Restroom Rehabilitation at Terminal B (Phase 3 & 4) December 20, 2010 THE REQUEST FOR BIDS (RFB) FOR

More information

Appendix J - Custom Uniformat for EDU Migration

Appendix J - Custom Uniformat for EDU Migration Appendix J - Custom Uniformat for EDU Migration Nr. MTC Uniformat for VFA.facility Life (Years) Weight (1-100) Out of Scope Cost Y/N 1 A Substructure 150 N 2 A10 Foundations 150 N 3 A1010 Standard Foundations

More information

HILLSIDE ELEMENTARY SCHOOL. Overview: Livingston School District Hillside Elementary School

HILLSIDE ELEMENTARY SCHOOL. Overview: Livingston School District Hillside Elementary School HILLSIDE ELEMENTARY SCHOOL Overview: The is located at 98 Belmont Drive and consists of a two-story building which has had a number of additions added to it over the years, the latest of which was a two-story

More information

MADELEY RANCH ELEMENTARY SCHOOL

MADELEY RANCH ELEMENTARY SCHOOL MADELEY RANCH ELEMENTARY SCHOOL CAMPUS DATA MADELEY RANCH ELEMENTARY SCHOOL 3500 Madeley Ranch Road, Montgomery TX 77356 Year Built 2009 Approx. Total Square Footage Grades Served 94,750 Pre-K - 4 th

More information

4.1.3 Project Manual

4.1.3 Project Manual 4.1.3 Project Manual (*Section requires Filed Sub-Bid) PROCUREMENT AND CONTRACTING REQUIREMENTS GROUP Division 00 Procurement and Contracting Requirements Section 00 01 03 Project Directory Section 01

More information

New Ringgold Middle School. Project Slideshow August 26, 2017

New Ringgold Middle School. Project Slideshow August 26, 2017 New Ringgold Middle School Project Slideshow August 26, 2017 Aerial Photo from West Provided by Hudson Group Taken 8.16.2017 Aerial Photo from North Provided by Hudson Group Taken 8.16.2017 Aerial Photo

More information

Colorado Springs School District 11 Design & Construction Standards and Guideline Specifications Revision date: March 6, 2018

Colorado Springs School District 11 Design & Construction Standards and Guideline Specifications Revision date: March 6, 2018 DIVISION 9 - FINISHES A. GENERAL Finishes and items listed below shall be minimum acceptable for area indicated. 1. Kitchen and toilet room walls and ceilings must be constructed of materials that will

More information

DIVISION 9 FINISHES. This Article on Codes, Regulation and Standards shall apply to all Divisions of the Building Standards

DIVISION 9 FINISHES. This Article on Codes, Regulation and Standards shall apply to all Divisions of the Building Standards DIVISION 9 FINISHES This Article on Codes, Regulation and Standards shall apply to all Divisions of the Building Standards 1 Table of Contents SECTION 09 05 13 COMMON FINISHES 2 SECTION 09 51 23 ACOUSTICAL

More information

CONSTRUCTION REPORT. Zionsville Community Schools Zionsville, Indiana. October 2014 TSC NO

CONSTRUCTION REPORT. Zionsville Community Schools Zionsville, Indiana. October 2014 TSC NO CONSTRUCTION REPORT TSC NO. 21319.1 October 2014 Zionsville Community Schools Zionsville, Indiana The SKILLMAN Corporation Project Administration Construction Management Zionsville Community Schools 2005

More information

CEFPI Monthly Meeting

CEFPI Monthly Meeting CEFPI Monthly Meeting LISD School Construction Cost Information Background Information School Cost Information How Does LISD Compare? Other District Comparisons Background Information Cost Discussion Type

More information

STANDARD PLAN RELEASE SUMMARY(SPR) Facilities Management Department

STANDARD PLAN RELEASE SUMMARY(SPR) Facilities Management Department STANDARD PLAN RELEASE SUMMARY(SPR) Facilities Management Department Building Design: Nauvoo 00 Release Date: February 2001 Release Number: 1 Summarized below is a list of modifications made to the Standard

More information

L K J H F E OPEN ADMIN. AREA V.S. MANAGER WOMEN L.I.C. STN. STL. FLASHING, TYP. UPPER ROOF EL. +41'-0" METAL ROOFING SYSTEM

L K J H F E OPEN ADMIN. AREA V.S. MANAGER WOMEN L.I.C. STN. STL. FLASHING, TYP. UPPER ROOF EL. +41'-0 METAL ROOFING SYSTEM Museum Fndtn 60 W. 3th Street Overland Park, KS 663 L K J H F E Boston, MA 008 SERVICE WING ROOF EL. +9'-0" Section 3/3" = '-0" LOWER ROOF EL. +37'-6" Q P N M MECHANICAL MOPF COLLECTION STORAGE CRATE STORAGE

More information

Limited Visual Assessment Report

Limited Visual Assessment Report Terramar School Peoria, Arizona July 27, 2015 Terracon Project No. 65157316 Prepared for: Deer Valley Unified School District Glendale, Arizona Prepared by: Terracon Consultants, Inc. Tempe, Arizona July

More information

BRUCE-MONROE ELEMENTARY SCHOOL AT PARK VIEW MODERNIZATION HISTORIC PRESERVATION REVIEW

BRUCE-MONROE ELEMENTARY SCHOOL AT PARK VIEW MODERNIZATION HISTORIC PRESERVATION REVIEW HISTORIC PRESERVATION REVIEW submitted to: DC Historic Preservation Office Office of Planning ARCHITECTS ARCHITECTURAL NARRATIVE Bruce Monroe Elementary School at Park View is among the schools included

More information

Building Excellence IV Capital Levy Projects Under Construction

Building Excellence IV Capital Levy Projects Under Construction Building Excellence IV Capital Levy Projects Under Construction Project Slide Number Arbor Heights Elementary School 2 Cascadia Elementary School & Robert Eagle Staff Middle School 14 Genesee Hill Elementary

More information

LUFacilities Policy Service Level Agreement v1.1

LUFacilities Policy Service Level Agreement v1.1 PURPOSE The Service Level Agreement (SLA) for University provides a detailed list of services offered by the LU Department. The SLA identifies which services are funded by the approved Lehigh University

More information

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10 CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES 283 Chapter 10 FUNCTIONAL REQUIREMENTS FUNCTIONAL REQUIREMENTS 10.1 PLASTERWORK Workmanship i. All workmanship must be within the tolerances

More information

G703 Continuation Sheet Minimum Schedule of Values Please use the breakdown listed below when submitting your billing for the project

G703 Continuation Sheet Minimum Schedule of Values Please use the breakdown listed below when submitting your billing for the project Billing Requirements G703 Continuation Sheet Minimum Schedule of Values Please use the breakdown listed below when submitting your billing for the project Sitework / Paving Excavation and Grading Labor

More information

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES CONTENTS 10.1 PLASTERWORK 10.2 2 ND AND 3 RD FIX FINISHES FUNCTIONAL REQUIREMENT 10.1 Plasterwork Workmanship Design Technical Manual TS-011-09-010412 i. All workmanship must be within defined tolerances

More information

Mold resistant, paperless gypsum board shall be used in bath, kitchen, and janitor locations.

Mold resistant, paperless gypsum board shall be used in bath, kitchen, and janitor locations. 09 00 00 - FINISHES 09 00 00 General Information CCU is continuing its investigation into preferred floor surface materials. In general, selection of floor materials should consider the environmental impact

More information

Interior finishes include wall finishes, floor finishes, wall base finishes, and ceiling finishes.

Interior finishes include wall finishes, floor finishes, wall base finishes, and ceiling finishes. 6. ENGINEERING SYSTEMS REQUIREMENTS C30 INTERIOR FINISHES SYSTEMS REQUIREMENTS INTERIOR FINISHES TEMPLATE 02/18 Instructions for using this template: There are template files for each UNIFORMAT Level 2

More information

1/8"/FT TAPERED 1.5" MIN START CITY OF FLORISSANT JUSTICE CENTER 4575 WASHINGTON ST. FLORISSANT, MO THE PROFESSIONAL WHOSE SIGNATURE AND PERSONA

1/8/FT TAPERED 1.5 MIN START CITY OF FLORISSANT JUSTICE CENTER 4575 WASHINGTON ST. FLORISSANT, MO THE PROFESSIONAL WHOSE SIGNATURE AND PERSONA 1/8"/FT TAPERED 1.5" MIN START CITY OF FLORISSANT JUSTICE CENTER 4575 WASHINGTON ST. FLORISSANT, MO 601 THE PROFESSIONAL WHOSE SIGNATURE AND PERSONAL SEAL APPEAR HEARON, ASSUMES RESPONSIBILITY ONLY FOR

More information

327 King Street Exterior Repairs & Interior Renovations Project No. H15-N200-PG

327 King Street Exterior Repairs & Interior Renovations Project No. H15-N200-PG StudioA Architecture ADDENDUM NO. 2 Date: 11 October 2013 Re: 327 King Street Exterior Repairs & Interior Renovations Project No. H15-N200-PG From: Whitney Powers To: Bidders/Planholders This Addendum

More information

DESIGN AND CONSTRUCTION STANDARDS. Section 2: Standards for Specific Categories of Work. Laboratory Standards

DESIGN AND CONSTRUCTION STANDARDS. Section 2: Standards for Specific Categories of Work. Laboratory Standards Laboratory Standards These criteria include general planning guidelines. They are intended for use of Designers during the design phases of the project. Planning Assumptions Overview In order to maximize

More information

DIVISION 9 - FINISHES

DIVISION 9 - FINISHES 09100 METAL SUPPORT SYSTEMS 09120 Ceiling Suspension Systems 09130 Wall/Partition Support Systems 09250 GYPSUM BOARD 09260 Gypsum Board Systems - Demountable 09300 TILE 09400 TERRAZZO 09500 ACOUSTICAL

More information

Existing Site Aerial Frederick High School Feasibility Study September 5, 2012

Existing Site Aerial Frederick High School Feasibility Study September 5, 2012 Existing Site Aerial Building Developmental History 1981 1966 1939 1977 1978 1955 1966 Exterior Roof: Most of existing roof has multi ply built up roofing. Some areas have gravel ballast, others have cap

More information

SECTION GYPSUM BOARD ASSEMBLIES

SECTION GYPSUM BOARD ASSEMBLIES SECTION 09 21 16 GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Metal stud wall and ceiling framing, 20 gauge. B. Metal channel suspended ceiling framing. C. Gypsum board. D. Gypsum sheathing.

More information

FLOOR COVERING Arch206 BC-II Spring 2016

FLOOR COVERING Arch206 BC-II Spring 2016 FLOOR COVERING Arch206 BC-II Spring 2016 Floor coverings 1. Subfloors 2. Selection criteria for floor coverings 3. Ceramic and Stone Tile Flooring 4. Stone Panel Flooring 5. Terrazzo Flooring 6. Carpet

More information

Demolition Plan A1 A3. Scale: 3/32" = 1'-0" Arch. Men N.I.C. Elev. Lobby. Stairs N.I.C. N.I.C. Women N.I.C. Issued for Tender.

Demolition Plan A1 A3. Scale: 3/32 = 1'-0 Arch. Men N.I.C. Elev. Lobby. Stairs N.I.C. N.I.C. Women N.I.C. Issued for Tender. inc. 400-7 avenue edmonton, alberta, canada tr y t: (780) 48 47 f: (780) 48 00 e: lesnider@shaw.ca 4 door to North Common Corridor doors to door to F. H. C. Men Women ELEC/TEL UP Stairs DN F. H. C. DN

More information

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD SECTION 09250 GYPSUM BOARD PART 1GENERAL 1.1 SUMMARY A. Related Documents: General and Supplementary Conditions of the Contract, Division 1 - General Requirements, and Drawings are collectively applicable

More information

STATE UNIVERSITY CONSTRUCTION FUND

STATE UNIVERSITY CONSTRUCTION FUND DIRECTIVE 1C-3 Issue date: August 2012 1. General MATERIAL AND COLOR SELECTIONS This Directive is applicable to all projects where materials and finishes in public areas are involved, from stand-alone

More information

SERIES 0 BIDDING REQUIREMENTS AND CONTRACT FORMS

SERIES 0 BIDDING REQUIREMENTS AND CONTRACT FORMS SERIES 0 BIDDING REQUIREMENTS AND CONTRACT FORMS INDIANA UNIVERSITY BIDDING REQUIREMENTS NOTICE TO BIDDERS BID FORM INSTRUCTIONS TO BIDDERS CONTRACTOR S BID FOR PUBLIC WORK - FORM 96 (REVISED 2005) MINORITY,

More information

1.3 Work shall include all reinforcement and accessories necessary to complete installation.

1.3 Work shall include all reinforcement and accessories necessary to complete installation. CERAMIC TILING GENERAL INFORMATION 1.1 Ceramic mosaic tile floors and bases, glazed wall tile wainscots and walls, and marble thresholds. 1.2 Installation will typically be with latex-portland cement mortar

More information

DIVISION 9 - FINISHES

DIVISION 9 - FINISHES DIVISION 9 - FINISHES I. GENERAL A. This division contains the following elements: 1. Floor Finishes. 2. Wall Finishes. 3. Ceiling Finishes. 4. Paint Finishes. B. Provide finish materials durable and able

More information

Franklin Hall Renovation TABLE OF Document Indiana University Bloomington

Franklin Hall Renovation TABLE OF Document Indiana University Bloomington VPS Project No. 2013022.00 Page 1 SPECIFICATIONS VOLUME I INTRODUCTORY INFORMATION Document 000010 - Table of Contents... 6 Document 000011 - Certification and Seals... 2 Document 000012 - Project Directory...

More information

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 29 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

E. Popcorn or other spray applied textures on ceiling or walls are not acceptable.

E. Popcorn or other spray applied textures on ceiling or walls are not acceptable. DIVISION 9 09 2000 GYPSUM BOARD ASSEMBLIES A. Drywall finish: Drywall finishing to conform to Level 5 finish in accordance with Association of Wall and Ceiling Industries (AWCI). Drywall MUST continue

More information

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No. SECTION 092900 GYPSUM BOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Capital Projects Update

Capital Projects Update Issaquah School District Issaquah High School Reconstruction March 2010 Installation of exterior masonry and siding panels continues on the classroom wings. Library windows are complete. Window and storefront

More information

ALL DIMENSIONS FROM FINISHED FACE OF PARTITION TO FINISHED FACE OF PARTITION UNLESS OTHERWISE NOTED.

ALL DIMENSIONS FROM FINISHED FACE OF PARTITION TO FINISHED FACE OF PARTITION UNLESS OTHERWISE NOTED. ALL DIMENSIONS FROM FINISHED FACE OF PARTITION TO FINISHED FACE OF PARTITION UNLESS OTHERWISE NOTED. PARTITION CONSTRUCTION TO BE 3 5/8 METAL STUDS 24 ON CENTER WITH 5/8 TYPE X GYPSUM BOARDS BOTH SIDES.

More information

Athletic Complex Renovations Chattahoochee Valley Community College Phenix City, AL BC No.:

Athletic Complex Renovations Chattahoochee Valley Community College Phenix City, AL BC No.: ADDENDUM NO.2 Date: July 27, 2012 blondheim + Mixon, inc. A R C H I T E C T S 2 4 0 Ea st Broad Street P.O. Box One Eufaula, AL 36027 p. 3 3 4. 6 8 7. 8 0 5 7 f. 3 3 4. 6 8 7. 7 9 0 5 Project: Athletic

More information

Timberglen Recreation Center Summary

Timberglen Recreation Center Summary Timberglen Recreation Center Summary Address Building Purpose 3810 Timberglen Road Dallas, TX 75287 Recreation Center Original Year of Construction 2003 Building Area 15,000 SF Inspection Date August 2,

More information

NYC Department of Education

NYC Department of Education Building Assessment Survey 2017-2018 Asset: HS FOR MATH, SCI & ENGINEERING-M, 240 CONVENT AVENUE, New York, 10031 Inspection Id Inspection Type Time In Last Edited SA : Architectural - Senior 2017-12-20

More information

TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up

TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM Form 15 Work Write-Up Owner-Builder Applicant Owner-Builder Co-Applicant Physical Address: City,

More information