2 IEQ- P1: MINIMUM INDOOR AIR QUALITY PERFORMANCE To establish minimum indoor air quality (IAQ) performance to enhance indoor air quality in buildings, thus contributing to the comfort and well-being of the occupants. PREREQUISITE REQUIREMENTS Meet ventilation requirements Naturally Ventilated Spaces For naturally ventilated spaces (and for mixed-mode systems when the mechanical ventilation is inactivated), determine the minimum outdoor air opening and space configuration requirements using the natural ventilation procedure from ASHRAE Standard Confirm that natural ventilation is an effective strategy for the project by following the flow diagram in the Chartered Institution of Building Services Engineers (CIBSE) Applications Manual AM10, March 2005, Natural Ventilation in Non-domestic Buildings, Figure 2.8, and meet the requirements of ASHRAE Standard , Section 4. Mechanically Ventilated Spaces For mechanically ventilated spaces (and for mixed-mode systems when the mechanical ventilation is activated), determine the minimum outdoor air intake flow for mechanical ventilation systems using the ventilation rate procedure from ASHRAE ASHRAE Standard Meet the minimum requirements of ASHRAE Standard , Sections 4 7, Ventilation for Acceptable Indoor Air Quality (with errata). All Spaces The indoor air quality procedure defined in ASHRAE Standard may not be used to comply with this prerequisite. POTENTIAL TECHNOLOGIES AND STRATEGIES Design ventilation systems to meet or exceed the minimum outdoor air ventilation rates as described in the ASHRAE standard. Balance the impacts of ventilation rates on energy use and indoor air quality to optimize for energy efficiency and occupant comfort. 73

3 IEQ- P2: ENVIRONMENTAL TOBACCO SMOKE CONTROL To prevent or minimize exposure of building occupants, indoor surfaces, and ventilation air distribution systems to environmental tobacco smoke (ETS). PREREQUISITE REQUIREMENTS Prohibit smoking inside the building. Prohibit smoking outside the building except in designated smoking areas located at least 25 feet (7.5 meters) from all entries, outdoor air intakes, and operable windows. The nosmoking policy also applies to spaces outside the property line used for business purposes. If the requirement to prohibit smoking within 25 feet (7.5 meters) cannot be implemented because of code, provide documentation of these regulations. Signage must be posted within 10 feet (3 meters) of all building entrances indicating the no-smoking policy. POTENTIAL TECHNOLOGIES AND STRATEGIES Prohibit smoking in commercial buildings or effectively control the ventilation air in smoking rooms. 74

4 IEQ- P3: CONSTRUCTION IAQ MANAGEMENT To reduce indoor air quality (IAQ) problems resulting from construction or renovation and promote the comfort and well-being of construction workers and building occupants. PREREQUISITE REQUIREMENTS OR OPTION 1 Construction IAQ Management Plan Demonstrate the development and implementation of a comprehensive Construction IAQ Management Plan. At a minimum the plan must address the following: Source Control Building Flush Out Resuming Normal Building Operation To demonstrate compliance the Client shall submit a report prepared by a suitably qualified person documenting effective implementation of a Construction IAQ Management Plan appropriate to the scale and extent of the development including, but not limited to, the following: A copy of the Plan Evidence of measures showing protection of ducts, on-site storage or protection of installed absorptive materials Checklists, worksheets, notifications, deficiencies or resolutions related to construction IAQ issues; Documentation that demonstrates implementation of construction IAQ management measures during construction Details of filtration media used during construction and installed immediately prior to occupancy Documentation for duct cleaning and testing. OPTION 2 Filter replacement and flush-out The Client shall submit a report prepared by a suitably qualified person detailing the technical information for the filtration media used during construction and installed immediately prior to occupancy. The report shall also detail building flush-out procedures including actual dates of the flush-out. Where it can be demonstrated that filtration media used had a Minimum Efficiency Reporting Value (MERV) of 13 as determined by ASHRAE performance specification, and a minimum one-week building flush-out with new filtration media at 50% outside air was carried out after construction and prior to occupancy, the credit shall be awarded. 75

5 REQUIRED SUBMISSION Assessment of the duration required for pre-occupancy flush-out as follows: Estimation of pre-occupancy flush-out based on likely ambient conditions according to the project schedule. Estimation of pre-occupancy flush-out based on the most onerous ambient conditions to demonstrate possible maximum impact of project delays. POTENTIAL TECHNOLOGIES AND STRATEGIES Adopt an IAQ management plan to protect the heating, ventilation, and air conditioning (HVAC) system during construction, control pollutant sources, and interrupt contamination pathways. Sequence the installation of materials to avoid contamination of absorptive materials such as insulation, carpeting, ceiling tile and gypsum wallboard. 76

6 IEQ- 1: ENHANCED INDOOR AIR QUALITY STRATEGIES To promote occupants comfort, well-being, and productivity by improving indoor air quality. 4 S REQUIREMENTS OR OPTION 1 (4 S) Enhanced IAQ Strategies Comply with the following requirements, as applicable. Mechanically ventilated spaces Interior cross-contamination prevention Filtration Naturally ventilated spaces Entryway systems Natural ventilation design calculations Mixed-mode systems Interior cross-contamination prevention Filtration Natural ventilation design calculations Mixed-mode design calculations A. Interior Cross-Contamination Prevention Sufficiently exhaust each space where hazardous gases or chemicals may be present or used (e.g., garages, HVAC rooms, generator and fuel storage spaces), using the exhaust rates determined in EQ Prerequisite Minimum Indoor Air Quality Performance. B. Filtration Each ventilation system that supplies outdoor air to occupied spaces must have particle filters or air-cleaning devices that meet one of the following filtration media requirements: Minimum efficiency reporting value (MERV) of 13 or higher Replace all air filtration media after completion of construction and before occupancy. C. Natural Ventilation Design Calculations Demonstrate that the system design for occupied spaces employs the appropriate strategies in Chartered Institution of Building Services Engineers (CIBSE) Applications Manual AM10, March 2005, Natural Ventilation in Non-Domestic Buildings, Section 2.4. D. Mixed-Mode Design Calculations Demonstrate that the system design for occupied spaces complies with CIBSE Applications Manual , Mixed Mode Ventilation. 77

7 OPTION 2 (4 S) Additional Enhanced IAQ Strategies Comply with the following requirements, as applicable. Mechanically ventilated spaces Exterior contamination prevention Increased ventilation Carbon dioxide monitoring Additional source control and monitoring Naturally ventilated spaces Exterior contamination prevention Additional source control and monitoring Natural ventilation room by room calculations Mixed-mode systems Exterior contamination prevention Increased ventilation Additional source control and monitoring Natural ventilation room-by-room calculations A. Exterior Contamination Prevention Design the project to minimize and control the entry of pollutants into the building. Ensure through the results of computational fluid dynamics modeling, Gaussian dispersion analyses, wind tunnel modeling, or tracer gas modeling that outdoor air contaminant concentrations at outdoor air intakes are below the thresholds listed in Nigeria Ambient Air Quality Standards. B. Increased Ventilation Increase breathing zone outdoor air ventilation rates to all occupied spaces by at least 30% above the minimum rates as determined in EQ Prerequisite for Minimum Indoor Air Quality Performance. C. Carbon Dioxide Monitoring Monitor concentrations within all densely occupied spaces. CO2 monitors must be between 3 and 6 feet (90 and 180 centimeters) above the floor. CO2 monitors must have an audible or visual indicator or alert the building automation system if the sensed CO2 concentration exceeds the set point by more than 10%. Calculate appropriate CO2 set points using methods in ASHRAE D. Additional Source Control and Monitoring For spaces where air contaminants are likely, evaluate potential sources of additional air contaminants besides CO2. Develop and implement a materials-handling plan to reduce the likelihood of contaminant release. Install monitoring systems with sensors designed to detect the specific contaminants. An alarm must indicate any unusual or unsafe conditions. E. Natural Ventilation Room-by-Room Calculations Follow CIBSE AM10, Section 4, Design Calculations, to predict that room-by-room airflows will provide effective natural ventilation. OR 78

8 OPTION 3 (4 S) Monitoring Indoor Air Quality Mechanically Ventilated Spaces For mechanically ventilated spaces (and for mixed-mode systems when the mechanical ventilation is activated), monitor outdoor air intake flow as follows: For variable air volume systems, provide a direct outdoor airflow measurement device capable of measuring the minimum outdoor air intake flow. This device must measure the minimum outdoor air intake flow with an accuracy of +/ 10% of the design minimum outdoor airflow rate, as defined by the ventilation requirements above. An alarm must indicate when the outdoor airflow value varies by 15% or more from the outdoor airflow set point. For constant-volume systems, balance outdoor airflow to the design minimum outdoor airflow rate defined by ASHRAE Standard (with errata but without addenda2), or higher. Install a current transducer on the supply fan, an airflow switch, or similar monitoring device. Naturally Ventilated Spaces For naturally ventilated spaces (and for mixed-mode systems when the mechanical ventilation is inactivated), comply with at least one of the following strategies: Provide a direct exhaust airflow measurement device capable of measuring the exhaust airflow. This device must measure the exhaust airflow with an accuracy of +/ 10% of the design minimum exhaust airflow rate. An alarm must indicate when airflow values vary by 15% or more from the exhaust airflow set point. Provide automatic indication devices on all natural ventilation openings intended to meet the minimum opening requirements. An alarm must indicate when any one of the openings is closed during occupied hours. Monitor carbon dioxide (CO2) concentrations within each thermal zone. CO2 monitors must be between 3 and 6 feet (90 and 180 centimeters) above the floor and within the thermal zone. CO2 monitors must have an audible or visual indicator or alert the building automation system if the sensed CO2 concentration exceeds the set point by more than 10%. Calculate appropriate CO2 set points using the methods in ASHRAE

9 IEQ- 2: INDOOR AIR POLLUTANTS To minimize building occupant exposure to potentially hazardous particulates and chemical pollutants. 2 S REQUIREMENTS AND AND Encourage the use and specification of healthy materials and finishes which contain low volatile organic compounds (VOC) and formaldehyde. Use low VOC paint and coating throughout the building. Paints and Coatings to comply with requirements specified in international labeling schemes. Use low VOC carpet or flooring throughout the building. Use low VOC adhesive and sealant or no adhesive or sealant used. Use products with no added urea formaldehyde. These include: Composite wood and agrifiber products defined as: particleboard, medium density fiberboard (MDF), plywood, wheatboard, strawboard, panel substrates and door cores, AND Laminating adhesives used to fabricate on-site and shop-applied composite wood and agrifiber assemblies REQUIRED SUBMISSION Summary report identifying areas where the low VOC materials will be installed and how the credit compliance is to be me (Design Assessment). As built drawings showing where low VOC materials or products are used. List of products installed that meet the credit requirements, and their specifications. Manufacturer s information including data sheets, certificates or test reports to demonstrate credit compliance Photographic evidence of each typical low VOC installation Describe any deviations or additions to the Design Assessment 80

10 IEQ- 3: INDOOR AIR QUALITY ASSESSMENT BEFORE AND DURING OCCUPANCY Develop and implement an Indoor Air Quality Management Plan for the building. 1 S REQUIREMENTS OR Encourage the use and specification of healthy materials and finishes which contain low volatile organic compounds (VOC) and formaldehyde. Pre-Occupancy Phase OPTION 1 Perform a building flush-out by supplying outdoor air to provide not less than 10 air changes/ hour (ACH) for at least 30 minutes operation before occupancy and continuous minimum 1 ACH during the initial 14 days occupancy of the completed building. OPTION 2 If low VOC materials and low formaldehyde composite wood are used (EQ4 is achieved), then building flushout can be performed by supplying outdoor air to provide not less than 10 ACH for at least 15 minutes operation or not less than 6 ACH for at least 30 minutes operation and continuous 1ACH during the initial 7 days occupancy of the completed building. During Occupancy Phase Install a permanent air flushing system of at least 10 ACH operation for use during occupancy stage. REQUIRED SUBMISSION Summary report outlining the strategies and procedures to be taken to meet the credit requirements (Design Assessment) Report on building flush-out procedure including the actual dates of the flush-out. If IAQ testing is carried out, a report to outline the procedures undertaken and the results of the testing to verify if the credit requirements are met or not should be provided. If not, corrective measures must be taken Describe any deviations or additions to the Design Assessment. 81

11 IEQ- 4: THERMAL COMFORT AND CONTROLS To provide a high level of thermal comfort system control by individual occupants or groups in multi occupant spaces and promote their productivity, comfort and well-being. 2 S REQUIREMENTS OPTION 1 (1 ) Thermal Zoning Demonstrate that all spaces within the building(s) have been modeled to determine zonal cooling demand and designed to have separately controllable thermal zones, as follows: Design for separate zones and controls for a maximum of 35m2 of open plan space on the perimeter of the building and a maximum of 70m2 of open plan space in the internal areas of the building. Each thermal zone must have thermostats that allow control over air speed or temperature as a minimum. For private enclosed spaces intended for individual use, one thermostatic controller must be provided that allows control over air speed or temperature as a minimum. Multi-occupant spaces intended for group must at least have one thermostatic controller. In the case where these spaces have movable internal partitions intended to sub-divide spaces, each space must have at least one thermostatic controller. OR OPTION 2 (1 ) Meet the requirements for both thermal comfort design and thermal comfort control. Design to ASHRAE 55 standards in conjunction with the relevant localized parameters Provide individual comfort control for 50% of the building occupants to enable adjustments to suit individual task needs and preferences. AND Provide comfort system control for all shared multi-occupant spaces to enable adjustments to suit group needs and preferences. OR OPTION 3 (1 ) Occupant Control Demonstrate individual control as follows: 82

12 Mechanical Ventilation The ventilation/temperature control system allows for occupant control over at least air temperature and / or air speed as follows: Provide occupancy sensors linked to HVAC control systems that automatically modulate temperature and air flow-rate based on occupancy down to a minimum design setback in all multi-occupant spaces. Comfort control can be provided by thermostatic controllers linked to on-floor plant or via supply air terminals directly controllable and easily accessible by occupants that allow control of temperature and/or flow-rate (such as terminals located at floor level, within workstations or via overhead terminals). Where thermostatic controllers are used in conjunction with on-floor plant, the plant must be capable of serving no more than two occupants. For private enclosed spaces intended for individual use, one thermostatic controller must be provided that allows control over air speed or temperature as a minimum. Any fully enclosed individual space that is less than 35m2 need only have one ventilation / temperature control system. In all space types, multi-occupant spaces intended for group activities (meeting rooms, conference halls) must have at least one thermostatic controller. Where these spaces have movable internal partitions intended to sub-divide spaces, each space must have at least one thermostatic controller. REQUIRED SUBMISSION Brief narrative describing how the project will meet the Credit Requirements. Zoning must match that in Prerequisite EA-P1 Minimum Energy Performance; Drawings of the mechanical ventilation systems, clearly indicating zone boundaries and zone references. Drawings must also highlight locations for thermostatic controllers intended for occupant control; Pearl Building Rating System: Design & Construction, Version 1.0, April of 223 Spreadsheet listing of each zone including its reference name, zone floor area, zone air temperature, zone resultant or operative temperature, zone peak cooling loads and floor peak simultaneous cooling loads; and Submission of spreadsheet results and associated plans for typical floors will only be accepted where equivalency can be demonstrated. 83

13 IEQ- 5: INTERIOR LIGHTING To promote occupants productivity, comfort, and well-being by providing high-quality lighting. 2 S REQUIREMENTS OR OPTION 1 (2 S) Lighting Control For at least 90% of individual occupant spaces, provide individual lighting controls that enable occupants to adjust the lighting to suit their individual tasks and preferences, with at least three lighting levels or scenes (on, off, midlevel). Midlevel is 30% to 70% of the maximum connected lighting load. For all shared multi-occupant spaces, meet all of the following requirements. Provide multi-zone control systems that enable occupants to adjust the lighting to meet group needs and preferences, with at least three lighting levels or scenes (on, off, midlevel). Lighting for any presentation or projection wall must be separately controlled. Locate switches or manual controls in the same space with the controlled luminaires. A person operating the controls must have a direct line of sight to the controlled luminaires. Achieve the prescribed lighting performance in each type of premises in respect of luminance and lighting quality. It is required to fulfill the following: Prescribed lighting performance in respect of maintained luminance and luminance variation is achieved; and The limiting unified glare rating is achieved and light sources have an appropriate color rendering index. Install occupancy sensors in all rooms intended for individual occupancy, conferencing or meeting rooms, open plan offices spaces and hallways or corridors. OPTION 2 (2 S) Electric lighting levels Demonstrate that office lighting design maintains a luminance level of no more than specified in MS1525:2007 for 90% of NLA as measured at the working plane (800 mm above the floor level). The ambient lighting level should be designed in accordance with the illuminance level recommended in MS1525:2007. Task lighting may be provided for occupants who require a higher lighting level either for their own preference or for various task needs. 84

14 IEQ- 6: DAYLIGHT GLARE CONTROL To connect building occupants with the outdoors, reinforce circadian rhythms, and reduce the use of electrical lighting by introducing daylight into the space. 3 S REQUIREMENTS Ensure day-lighting system is designed with adequate and proper glare control in order not to negate the benefits of day-lighting. Reduce discomfort of glare from natural light. Where blinds or screens are fitted on glazing and atrium as a base building, incorporate provisions to meet the following criteria; Eliminate glare from all direct sun penetration and Eliminate glare from diffused sky radiation for occupant workspace at viewing angles of 15 to 60 from the horizontal at eye level (typically 1.2m from floor level); Install daylight sensors to light fittings that receive sufficient daylight illuminance. Install occupancy sensors in all rooms intended for individual occupancy, conferencing or meeting rooms, open plan offices spaces and hallways or corridors. Demonstrate that glare control devices have been designed and installed, such as: Automated or manually controlled internal or external glare control devices to all windows Automated glare control devices must be connected to the building management system All manually controlled internal glare control devices must be no wider than 4 linear meters and be directly controllable by occupants. REQUIRED SUBMISSION FOR DESIGN ASSESSMENT Typical floor plans and sections showing variable position of glare control system. Brief description of proposed control mechanism to be provided Summary report to describe how view and daylight is assured when glare control system is engaged REQUIRED SUBMISSION FOR POST CONSTRUCTION ASSESSMENT As-Built drawings and specifications to confirm that building is constructed according to design drawing and specifications. Typical As-Built floor plans and sections showing position of glare control system. Description of control mechanism installed. Manufacturer s Information on the blind and control systems provided. Summary report to describe how view and daylight is assured when glare control system is engaged. Furnish photographs of each type of typical glared control system installed. Describe any deviations or additions to the DA submission. 85

15 IEQ- 7: ACOUSTIC PERFORMANCE To promote occupants productivity, comfort, and well-being by providing quality acoustic comfort. 2 S REQUIREMENTS Demonstrate that 90% of the NLA do not exceed the following ambient internal noise level: OR Within the entire building general office, space noise does not exceed 40dBAeq Within the baseline building office space, the sound level does not exceed 45dBAeq for open plan and does not exceed 40dBAeq for closed offices. Excessive noise can cause discomfort to occupants. Some of the solutions to ensure acceptable noise level is maintained include: Specify acoustical ceiling Specify furniture with sound absorbing surfaces on both sides Locate photocopiers, fax machines away from the main office areas in a separate area Insulate partition cavities Mechanical equipment room to be located away from office and conference rooms REQUIRED SUBMISSION FOR DESIGN ASSESSMENT Design report on strategies to ensure internal noise level is maintained at the prescribed levels. Floor plans showing location of Core, M&E, and equipment rooms. REQUIRED SUBMISSION FOR POST CONSTRUCTION ASSESSMENT Report describing the measured internal and external noise sources and features installed to achieve required noise level. As built drawings showing noise control features. Manufacturer s data sheets of the acoustic materials used in building. Describe any deviations or additions to the DA submission. 86

16 IEQ- 8: CO2 MONITORING AND CONTROL To promote occupants productivity, comfort, and well-being by providing a safe and pollutant free working environment. 1 REQUIREMENTS Install carbon dioxide (CO2) monitoring and control system with at least one (1) CO2 sensor at main return air points on each floor to facilitate continuous monitoring and adjustment of outside air ventilation rates to each floor, and ensure independent control of ventilation rates to maintain CO2 level < 1,000 ppm. REQUIRED SUBMISSION FOR DESIGN ASSESSMENT Submission of ventilation and control schematics together with description of how CO2 monitoring and controls are integrated into the ventilation design. REQUIRED SUBMISSION FOR POST CONSTRUCTION ASSESSMENT As-Built drawings showing the installed sensors and controls. Summary report on the ventilation design and CO2 monitoring and control system including information regarding the location, quantity of installed sensors, the operational parameters and setpoints. Manufacturer s information confirming the specifications of the CO2 sensors. Photographic evidence of typical installations. Describe any deviations or additions to the DA submission. 87

17 IEQ- 9: MOLD PREVENTION To promote occupants productivity, comfort, and well-being by providing a safe and pollutant free working environment. 1 REQUIREMENTS Design systems which reduce the risk of mold growth and its associated detrimental impact on occupant health in accordance with the WHO guidelines for indoor air quality. Demonstrate that the air-conditioning and mechanical ventilation system will maintain a positive indoor air pressure relative to the exterior, and can actively control indoor air humidity to be no more than 70% RH without the use of primary active reheat system (which consumes additional energy). Ensure that excessive moisture in building is taken into consideration during design, and be controlled and monitored during construction and operation stages by control of the following: OR Rainwater leakage through roof and walls Infiltration of moist air Diffusion of moisture through walls, roof and floors Groundwater intrusion into basements and crawl spaces through walls and floors Leaking or burst pipes Indoor moisture sources Construction moisture The above mentioned measures are not necessary or applicable if the building is fully naturally ventilated. REQUIRED SUBMISSION FOR DESIGN ASSESSMENT Summary report outlining the strategies adopted to meet the credit requirements. A copy of specifications for the strategies to be carried out. REQUIRED SUBMISSION FOR POST CONSTRUCTION ASSESSMENT As-Built drawings or as-built specifications confirming that the building has been constructed in accordance with the design stage drawings/specifications. Manufacturer s information on all relevant materials specified for mold prevention and/or resistance, to verify credit compliance. Documentation evidence during construction of the precautions taken for mold prevention, e.g. photographs of material storage and protection for items that are susceptible to mold growth as identified in the DA submission stage. Provide 24-hour record (during full occupancy) of Temperature-Relative Humidity measurements for at least two (2) areas acceptable to the GBI Certifier. Describe any deviations or additions to the DA submission. 88

18 IEQ- 10: QUALITY VIEWS To give building occupants a connection to the natural outdoor environment by providing quality views. 1 REQUIREMENTS Achieve a direct line of sight to the outdoors via vision glazing for 75% of all regularly occupied floor area. View glazing in the contributing area must provide a clear image of the exterior, not obstructed by frits, fibers, pattern glazing or added tints that distort color balance. Additionally, 75% of all regularly occupied floor area must have at least two of the four kinds of views: Multiple lines of sight to vision glazing in different directions of at least 90 degrees apart Views that include at least two of the following Flora and fauna or sky Movement Objects at least 8 meters from the exterior of the glazing Unobstructed views located within the distance of three times the head height of the vision glazing Include in the calculations any permanent interior obstructions. Moveable furniture may be excluded. Views into interior atria may be used to meet 30% of the required area. 89

19 IEQ- 11: POST OCCUPANCY COMFORT SURVEY To verify occupant satisfaction with the quality of the indoor environment. 1 REQUIREMENTS Conduct a post-occupancy comfort survey of building occupants within 12 months after occupancy/building completion. This survey should collect anonymous responses about thermal comfort, visual comfort and acoustic comfort in a building. It should include an assessment of overall satisfaction with thermal, visual and acoustic performance and identification of thermal-related, visual-related and acoustic-related problems. Develop a plan for corrective action if the survey results indicate that more than 20% of occupants are dissatisfied with the overall comfort in the building. This plan should include measurement of relevant environmental variables in problem areas. The relevant environmental variables include: Temperature, relative humidity, air speed and mean radiant temperature Lighting level and glare problem Background noise level Odor problem, CO2 level, VOCs, and particulate concentration REQUIRED SUBMISSION Summary report of the strategies that will be undertaken to meet the credit compliance. (Design Assessment) Survey questionnaire used to collect responses from the occupants. Objective measurement plan illustrating the areas and measurements undertaken. Analysis report of the results of the survey and measurements. Corrective action plan and measures undertaken to rectify the problem. Describe any deviations or additions to the Design Assessment. 90

LEED And Your Indoor Environment

LEED And Your Indoor Environment LEED And Your Indoor Environment An overview of LEED v3 and Indoor Air Quality David McCauley, CIE Council Certified Indoor Environmentalist ACAC CIE #1008005 USGBC's Mission To transform the way buildings

More information

LEED v4 Building Design and Construction Quiz #8 EQ

LEED v4 Building Design and Construction Quiz #8 EQ LEED v4 Building Design and Construction Quiz #8 EQ 1. Which of these is considered an unoccupied space? [Choose three] A. School classroom B. Mechanical room C. Meeting room D. Locker room E. Restroom

More information

Construction Indoor Air Quality (IAQ) Management Plan

Construction Indoor Air Quality (IAQ) Management Plan Denver School of Science & Technology Middle School 2000 Valentia Street Denver, CO 80238 Telephone: 303-643-5775 Main Fax: 303-673-5776 Construction Indoor Air Quality (IAQ) Management Plan Denver School

More information

A. The project is intended to achieve LEED Certification at the Silver Level per the U.S. Green Building Council LEED for Schools 2007 rating system.

A. The project is intended to achieve LEED Certification at the Silver Level per the U.S. Green Building Council LEED for Schools 2007 rating system. SECTION 23 01 01 HVAC LEED REQUIREMENTS PART 1 -GENERAL 1.1 WORK INCLUDES A. Compliance with LEED project requirements. B. Coordination of LEED construction phase activities. C. Data gathering of construction

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 01 8113.53 - SUSTAINABLE DESIGN REQUIREMENTS - GREEN GLOBES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

SECTION INDOOR AIR QUALITY MANAGEMENT PLAN. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION INDOOR AIR QUALITY MANAGEMENT PLAN. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. SECTION 018119 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting

More information

SECTION SUSTAINABLILITY CERTIFICATION REQUIREMENTS - GREEN GLOBES

SECTION SUSTAINABLILITY CERTIFICATION REQUIREMENTS - GREEN GLOBES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 01 81 13.21 SUSTAINABLILITY CERTIFICATION REQUIREMENTS - GREEN GLOBES A. This section describes general requirements and procedures to comply with the Green Building

More information

UNIVERSITY OF ROCHESTER DIVISION 01 SPECIFICATIONS November 4, 2013 SECTION SUSTAINABLE DESIGN REQUIREMENTS - LEED FOR NEW

UNIVERSITY OF ROCHESTER DIVISION 01 SPECIFICATIONS November 4, 2013 SECTION SUSTAINABLE DESIGN REQUIREMENTS - LEED FOR NEW SECTION 018113.13 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,

More information

CAMP BLANDING JOINT TRAINING CENTER CONSTRUCTION AND FACILITY MANAGEMENT OFFICE ARCHITECT S PROJECT # CFMO PROJECT #

CAMP BLANDING JOINT TRAINING CENTER CONSTRUCTION AND FACILITY MANAGEMENT OFFICE ARCHITECT S PROJECT # CFMO PROJECT # SECTION 018113.13 - PART 1 - GENERAL 1.1 SUMMARY A. Section includes general requirements and procedures for compliance with certain USGBC LEED prerequisites and credits needed for Project to obtain LEED

More information

Columbia Skylights may qualify your project for LEED points in the following categories: Columbia Skylights - Potential Contribution to LEED projects

Columbia Skylights may qualify your project for LEED points in the following categories: Columbia Skylights - Potential Contribution to LEED projects 3.0 Statement Columbia Skylights Statement for New Construction (NC) Version 3.0 Credit Documentation The Leadership in Energy and Environmental Design () Green Building Rating System promotes the adoption

More information

MEP's Letter of Assurance

MEP's Letter of Assurance MEP's Letter of Assurance Instructions Multifamily Residential WELL Certification is determined by onsite Performance Verification and documentation, including Letters of Assurance from the appropriate

More information

MEP's Letter of Assurance

MEP's Letter of Assurance MEP's Letter of Assurance Instructions WELL Certification is determined by onsite Performance Verification and documentation, including Letters of Assurance from the appropriate professionals overseeing

More information

Decorative Division. GANA Decorative Glass LEED White Paper Page 1 of 23

Decorative Division. GANA Decorative Glass LEED White Paper Page 1 of 23 Decorative Division White Paper on the Relevance of Decorative Glass Products to the U. S. Green Building Council Leadership in Energy and Environmental Design Green Building Rating System LEED NC Version

More information

Measuring Indoor Air Quality presented to AAFAME Members Nov. 14, 2017

Measuring Indoor Air Quality presented to AAFAME Members Nov. 14, 2017 Measuring Indoor Air Quality presented to AAFAME Members Nov. 14, 2017 What is Indoor Air Quality? Appropriate IAQ can be defined as a function of three different components: 1) appropriate thermal comfort,

More information

New Montgomery County Elementary School. Construction Indoor Air Quality Management Plan IEQc3.1 IAQ Plan During Construction

New Montgomery County Elementary School. Construction Indoor Air Quality Management Plan IEQc3.1 IAQ Plan During Construction New Montgomery County Elementary School Construction Indoor Air Quality Management Plan IEQc3.1 IAQ Plan During Construction LEED certification promotes environmentally friendly buildings and sites through

More information

LEED 2009 for New Construction and Major Renovations

LEED 2009 for New Construction and Major Renovations LEED 2009 for New Construction and Major Renovations Bayshore District Operations Building Project Checklist 4.28.6 20 4 0 Sustainable Sites Possible Points: 26 Y? N d/c Notes: Y C Prereq Construction

More information

THERMA-FUSER VARIABLE AIR VOLUME DIFFUSER SYSTEMS

THERMA-FUSER VARIABLE AIR VOLUME DIFFUSER SYSTEMS SUSTAINABLE DESIGN FORM 010.901 REV 1211 THERMA-FUSER VARIABLE AIR VOLUME DIFFUSER SYSTEMS SUSTAINABLE DESIGN GUIDE StopWaste.Org LEED-NC Platinum Energy Foundation LEED-CI Platinum Adobe East Tower LEED-EB

More information

MEP Engineer's Letter of Assurance

MEP Engineer's Letter of Assurance Instructions MEP Engineer's Letter of Assurance WELL Building Standard, Jan 2016 WELL Certification and WELL Core and Shell Compliance are determined by onsite Performance Verification and Documentation,

More information

Projected actual points. Responsible for UNC -- Project name. Remarks

Projected actual points. Responsible for UNC -- Project name. Remarks UNC LEED Checklist Total points available Projected Responsible for UNC -- Project name Cost documentation Sustainable Sites Prerequisite- Erosion and Sediment control Prerequisite REQ Y All campus projects

More information

LEED for Commercial Interiors

LEED for Commercial Interiors LEED-CI LEED for Commercial Interiors Kim Lam Renee Webley What is the LEED-CI Rating System? The benchmark for tenant improvements of new or existing office space. An integrated design tool that sets

More information

35% reduction in water use below code maximum 83% 88% 49% reduction in lighting power density 12%

35% reduction in water use below code maximum 83% 88% 49% reduction in lighting power density 12% Science Center Cabot Library Project LEED CI v4.0 1 Oxford Street, Cambridge, ma LEED Certified Project Profile December 2017 The Science Center Cabot Library project was comprised of renovating the entry,

More information

GBI AssesSment criteria for NON-RESIDENTIAL EXISTING BUILDING (NREB) FIRST EDITION JANUARY 0 Version. www.greenbuildingindex.org info@greenbuildingindex.org 4 & 6 Jalan Tangsi, 50480 Kuala Lumpur, Malaysia

More information

WMU Facility Life Cycle Design Guidelines Update (Approved by VP Van Der Kley & Facilities Management on 4/28/16)

WMU Facility Life Cycle Design Guidelines Update (Approved by VP Van Der Kley & Facilities Management on 4/28/16) Update (Approved by VP Van Der Kley & Facilities Management on 4/28/16) Developed by Sustainable Design Committee: Christopher Caprara, Devon Miller, Carolyn Noack, Eleonora Philopoulos, Kelsey Pitschel,

More information

DESIGN & CONSTRUCTION PHASE COMMISSIONING PLAN TEMPLATE

DESIGN & CONSTRUCTION PHASE COMMISSIONING PLAN TEMPLATE DESIGN & CONSTRUCTION PHASE COMMISSIONING PLAN TEMPLATE Based upon B3 Minnesota Sustainable Building Guidelines VERSION 2.1 Notes to the reader have been added to this document within numerous text boxes

More information

Architect's Letter of Assurance

Architect's Letter of Assurance Architect's Letter of Assurance Instructions WELL Certification is determined by onsite Performance Verification and documentation, including Letters of Assurance from the appropriate professionals overseeing

More information

Alpen Windows - LEED Impact Analysis

Alpen Windows - LEED Impact Analysis ALPEN WINDOWS MATERIALS: Energy Efficient Windows Alpen Windows - LEED Impact Analysis SECTION I. PRODUCT IDENTIFICATION Product Name: Alpen Windows Manufacturer: Alpen High Performance Products 6268 Monarch

More information

ADEC S SUSTAINABLE FUTURE SCHOOLS PROGRAM

ADEC S SUSTAINABLE FUTURE SCHOOLS PROGRAM APRIL 2012 ADEC S SUSTAINABLE FUTURE SCHOOLS PROGRAM Abu Dhabi Education Council Infrastructure and Facilities Division Jyoti Sharma, Senior Architect, Design Section WHY SUSTAINABILITY IS IMPORTANT UAE

More information

LEED Application Guide for Multiple Buildings and On Campus Building Projects

LEED Application Guide for Multiple Buildings and On Campus Building Projects LEED Application Guide for Multiple Buildings and On Campus Building Projects For Use with 2009 LEED Rating Systems for Design and Construction and Operations and Maintenance Released October 31, 2011

More information

AirRenew Gypsum Board Products - Frequently Asked Questions

AirRenew Gypsum Board Products - Frequently Asked Questions AirRenew Gypsum Board Products - Frequently Asked Questions What is AirRenew? AirRenew is a family of innovative gypsum board products that helps clean the air and improve indoor air quality. The gypsum

More information

LEED 2009 for Commercial Interiors. Presented by: Colleen McCafferty LEED AP Roselia Harris LEED AP

LEED 2009 for Commercial Interiors. Presented by: Colleen McCafferty LEED AP Roselia Harris LEED AP LEED 2009 for Commercial Interiors Presented by: Colleen McCafferty LEED AP Roselia Harris LEED AP Homes Commercial Interiors Core & Shell New Construction Schools Healthcare Existing Building Operations

More information

Genentech Building 20 Office LEED-CI Gold XL CONSTRUCTION

Genentech Building 20 Office LEED-CI Gold XL CONSTRUCTION Genentech Building 20 Office LEED-CI Gold Above and Beyond A LEED Gold 50,00 s.f. tenant improvement, the space was originally designed with a goal to achieve LEED silver certification. Innovative approaches

More information

500 WEST PUTNAM AVENUE GREENWICH, CT

500 WEST PUTNAM AVENUE GREENWICH, CT LEED-CI ANALYSIS June 2015 500 WEST PUTNAM AVENUE GREENWICH, CT To learn more please visit the sustainability section of our website: www.slgreen.com or contact Jay Black, SL Green s director of sustainability

More information

CALGREEN NON-RESIDENTIAL BUILDING Checklist

CALGREEN NON-RESIDENTIAL BUILDING Checklist CALGREEN NON-RESIDENTIAL BUILDING Checklist REVISED 11/18/14 New non-residential buildings shall be designed to include the green building mandatory measures specified in this checklist. This checklist

More information

Section SoundPly LR M25 Acoustic Ceiling Panels

Section SoundPly LR M25 Acoustic Ceiling Panels Section 095126 Acoustic Ceiling Panels PART 1 GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY A. Drawings and general conditions of the Contract, including General and Supplementary Conditions and Division 1

More information

ATTACHMENT N LEED PROJECT PROCEDURES

ATTACHMENT N LEED PROJECT PROCEDURES ATTACHMENT N LEED PROJECT PROCEDURES 1. All subcontractors, sub-subcontractors and suppliers at all tiers are to include the following items in their trade scope of work: a. Submit data and documentation

More information

ASHRAE/USGBC/IES Standard What Does It Mean for Commissioning Providers?

ASHRAE/USGBC/IES Standard What Does It Mean for Commissioning Providers? ASHRAE/USGBC/IES Standard 189.1-2009 What Does It Mean for Commissioning Providers? Kent W. Peterson, PE, FASHRAE, LEED AP P2S Engineering, Inc. kent.peterson@p2seng.com What is Standard 189.1? ANSI standard

More information

LEED Leadership in Energy and Environmental Design

LEED Leadership in Energy and Environmental Design LEED Leadership in Energy and Environmental Design United States Green Building Council (USGBC) Founded in 1993, the United States Green Building Council (USGBC) was the first Green Building Council formed

More information

LEED LEED. Leadership in Energy and Environmental Design. A voluntary, consensus-based. high-performance, sustainable buildings and neighborhoods

LEED LEED. Leadership in Energy and Environmental Design. A voluntary, consensus-based. high-performance, sustainable buildings and neighborhoods LEED An Introduction to LEED V3 2009 LEED Leadership in Energy and Environmental Design A voluntary, consensus-based national standard for developing high-performance, sustainable buildings and neighborhoods

More information

Environmental Stewardship Conference October 05, 2013 Energy Water and Sustainability (EWaS) Program

Environmental Stewardship Conference October 05, 2013 Energy Water and Sustainability (EWaS) Program Environmental Stewardship Conference October 05, 2013 Energy Water and Sustainability (EWaS) Program Agenda EWaS Overview History Who is EWaS? Mission EWaS Standards & Tools Energy Efficiency HVAC equipment

More information

Architect's Letter of Assurance

Architect's Letter of Assurance Architect's Letter of Assurance Instructions WELL Certification is determined by onsite Performance Verification and documentation, including Letters of Assurance from the appropriate professionals overseeing

More information

Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

Dan Int-Hout Chief Engineer, Krueger Richardson, Texas Effective Room Air Distribution Dan Int-Hout Chief Engineer, Krueger Richardson, Texas Where We Are Today: Agenda Overview LEED issues and Update Diffuser Selection Perimeter Acoustics Thermal Comfort

More information

Assessing Health and Wellbeing in Buildings

Assessing Health and Wellbeing in Buildings www.breeam.com Briefing Paper Assessing Health and Wellbeing in s Alignment between BREEAM and the WELL StandardTM Version 2: January 2018 Chris Ward & Alan Yates - BRE Shalini Ramesh, Nathan Stodola,

More information

37% 100% 100% PROJECT HIGHLIGHTS LEED Facts. Wiener Auditorium

37% 100% 100% PROJECT HIGHLIGHTS LEED Facts. Wiener Auditorium Taubman Building, 15 Eliot St., Cambridge, MA, 02138 LEED CI V2009 GOLD The is a 2,943 square foot space located in the Taubman Building of the Harvard Kennedy School of Government. The project scope includes

More information

2016 LEED Equivalency Analysis for Stanford Campus

2016 LEED Equivalency Analysis for Stanford Campus 6 LEED Equivalency Analysis for Stanford Campus Analysis performed by: Moira Hafer, LEED AP O+M Office of Sustainability Department of Sustainability & Energy Management Stanford University Category Type

More information

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis Senior Design Project for UNO Design of the International Studies Building: An Environmental Analysis Design Intent Implement Passive & Active design strategies in order to make the building: More Energy

More information

Indoor Air Quality Management Plan

Indoor Air Quality Management Plan Indoor Air Quality Management Plan Environmental Health, Safety, and Risk Management Department Box 6113, SFA Station Nacogdoches, Texas 75962-6113 Established: May, 26, 2010 Revised: January 2011 Introduction

More information

VOL. 2/ DESIGN+ CONSTRUCTION. Group 3 Projects. Building Design and Performance Standards. University of Hawaii at Manoa

VOL. 2/ DESIGN+ CONSTRUCTION. Group 3 Projects. Building Design and Performance Standards. University of Hawaii at Manoa University of Hawaii at Manoa Building Design and Performance Standards VOL. 2/ DESIGN+ CONSTRUCTION Group 3 Projects To be used by Design and Construction Teams [BLANK] Page 2 of 66 UHM BDPS- D+C GROUP

More information

Architect's Letter of Assurance

Architect's Letter of Assurance Architect's Letter of Assurance Instructions WELL Certification is determined by onsite Performance Verification and documentation, including Letters of Assurance from the appropriate professionals overseeing

More information

CONTENTS. 71 Section 01352, #7 (Life Cycle Cost and Life Cycle Assessment) 2/1/12 Modified entire section 72 Section 01352, #8 (Sustainability

CONTENTS. 71 Section 01352, #7 (Life Cycle Cost and Life Cycle Assessment) 2/1/12 Modified entire section 72 Section 01352, #8 (Sustainability 01352 Sustainable Design Requirements This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications

More information

LEED CERTIFICATION PROJECT REVIEW REPORT

LEED CERTIFICATION PROJECT REVIEW REPORT LEED CERTIFICATION PROJECT REVIEW REPORT How to Interpret this Report Purpose Leadership in Energy and Environmental Design (LEED) was designed by the US Green Building Council to encourage and facilitate

More information

A Building Commissioning Overview. Presented by: Goetting & Associates Commissioning

A Building Commissioning Overview. Presented by: Goetting & Associates Commissioning A Building Commissioning Overview Presented by: Goetting & Associates Commissioning www.goettingcx.com What is the Definition of Commissioning? Building Commissioning is a Quality Assurance Process of

More information

I. CONSTRUCTION WASTE MANAGEMENT PLAN II. CONSTRUCTION INDOOR AIR QUALITY MANAGEMENT PLAN

I. CONSTRUCTION WASTE MANAGEMENT PLAN II. CONSTRUCTION INDOOR AIR QUALITY MANAGEMENT PLAN RECOMMENDED TENANT CONSTRUCTION PLANS June 2015 I. CONSTRUCTION WASTE MANAGEMENT PLAN II. CONSTRUCTION INDOOR AIR QUALITY MANAGEMENT PLAN To learn more please visit the sustainability section of our website:

More information

Indoor Air Quality Tools for Schools

Indoor Air Quality Tools for Schools CT School Indoor Environment Resource Team 2nd Training Session: Walkthrough Investigations Indoor Air Quality Tools for Schools Agenda: Welcome, Introductions Show and Tell: Presentation of Blueprints,

More information

DISPLACEMENT VENTILATION

DISPLACEMENT VENTILATION DISPLACEMENT VENTILATION D3 OVERVIEW The fundamental approach to displacement ventilation utilizes the natural buoyancy forces created by the convective flows from heat sources in the space. As supply

More information

LEED Application Guide for Multiple Buildings and On-Campus Building Projects

LEED Application Guide for Multiple Buildings and On-Campus Building Projects LEED Application Guide for Multiple Buildings and On-Campus Building Projects For Use with 2009 LEED Rating Systems for Design and Construction and Operations and Maintenance Released October 31, 2011

More information

ASHRAE and Indoor Air Quality

ASHRAE and Indoor Air Quality ASHRAE 62.2-2013 and Indoor Air Quality Weatherize Ohio Conference October 27 29, 2015 The State of Ohio is an Equal Opportunity Employer and Provider of ADA Services Introduction ASHRAE: Why is it needed?

More information

ASHRAE 62.2: What s New in 2016

ASHRAE 62.2: What s New in 2016 ASHRAE 62.2: What s New in 2016 Rick Karg 2016 Residential Energy Dynamics, LLC What We Will Talk About Overview of mechanics of 62.2-2016. Logic behind the Standard. Sizing local ventilation (exhaust-only).

More information

Balco, Inc. PC Series Partition Closure Systems

Balco, Inc. PC Series Partition Closure Systems Balco, Inc. PC Series Partition Closure Systems Applicable Rating Systems: CI - Commercial Interiors RETAIL CI - Retail, Commercial Interiors Balco, Inc. PC Series Partition Closure Systems Contributes

More information

2013 City of Oakland CALGreen Checklist for NEW NON-RESIDENTIAL BUILDINGS

2013 City of Oakland CALGreen Checklist for NEW NON-RESIDENTIAL BUILDINGS 2013 City of Oakland CALGreen Checklist for NEW NON-RESIDENTIAL BUILDINGS Scope: The provisions of this checklist apply only to newly constructed non-residential buildings. Repairs (not additions or alterations)

More information

Model Written Indoor Air Quality Program. The Summit Board of Education Administrative Offices 14 Beekman Terrace Summit, NJ

Model Written Indoor Air Quality Program. The Summit Board of Education Administrative Offices 14 Beekman Terrace Summit, NJ Model Written Indoor Air Quality Program Summit Public Schools The Summit Board of Education Administrative Offices 14 Beekman Terrace Summit, NJ 07901-1702 Prepared by: Mr. Louis J. Pepe, RSBA Mr. Angelo

More information

GREEN STAR NZ - Interiors 2009 MANAGEMENT. Last updated 27/05/2014 CATEGORY WEIGHTING: 14% No. of Points Available

GREEN STAR NZ - Interiors 2009 MANAGEMENT. Last updated 27/05/2014 CATEGORY WEIGHTING: 14% No. of Points Available MANAGEMENT CATEGORY WEIGHTING: 4% MAN- Green Star NZ To encourage and recognise the engagement Up to three points are awarded where it can be demonstrated that professionals who can assist the project

More information

LEED NC (Version ) Credit Guide The University of Texas at Austin

LEED NC (Version ) Credit Guide The University of Texas at Austin INTRODUCTION This Credit Guide is intended to serve as a guideline for project teams to understand the University s sustainability goals and priorities and how they relate to LEED credits. The University

More information

SACRAMENTO County New Animal Care Facility LEED Elements

SACRAMENTO County New Animal Care Facility LEED Elements Construction Activity Pollution Prevention We reduced pollution from construction activities by controlling soil erosion, waterway sedimentation, and airborne dust generation by creating an Erosion and

More information

The 2010 California Green Building Code; "CalGreen" effective January 1st, 2011

The 2010 California Green Building Code; CalGreen effective January 1st, 2011 1 The 2010 California Green Building Code; "CalGreen" effective January 1st, 2011 Existing Culver City Building Safety Division Green Programs: The Culver City Mandatory Photovoltaic Requirement, effective

More information

360 HAMILTON AVENUE WHITE PLAINS, NY

360 HAMILTON AVENUE WHITE PLAINS, NY LEED-CI ANALYSIS June 2015 360 HAMILTON AVENUE WHITE PLAINS, NY To learn more please visit the sustainability section of our website: www.slgreen.com or contact Jay Black, SL Green s director of sustainability

More information

CITY OF ORANGE BUILDING DIVISION 2016 Green Building Code Requirements For Residential Construction

CITY OF ORANGE BUILDING DIVISION 2016 Green Building Code Requirements For Residential Construction CITY OF ORANGE BUILDING DIVISION 2016 Green Building Code Requirements For Residential Construction In order to facilitate sustainable construction practices, all new projects* must comply with the State

More information

LEED REQUIREMENTS. Source reference: Supplemental Guidance to the Minimum Program Requirements (MPR), Rev. 2, 9/1/2011

LEED REQUIREMENTS. Source reference: Supplemental Guidance to the Minimum Program Requirements (MPR), Rev. 2, 9/1/2011 OVERVIEW: The University of Illinois at Urbana-Champaign Facilities Standards includes language to comply with LEED Building Design and Construction Rating System developed by the U.S. Green Building Council.

More information

BUILDING FOR OUR FUTURE

BUILDING FOR OUR FUTURE BUILDING FOR OUR FUTURE The John T. Chambers Technology Center is a LEED Certified Building The Leadership in Energy and Environmental Design (LEED) Green Building Rating System is a voluntary national

More information

What Contractors Need to Know about LEED Commissioning & IAQ Management

What Contractors Need to Know about LEED Commissioning & IAQ Management What Contractors Need to Know about LEED Commissioning & IAQ Management Presented by Energy Ace, Inc. Wayne Robertson, PE, CxA What is Commissioning? Commissioning is a systematic process of assuring that

More information

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort Please add relevant logo here Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort Presented by: Peter J. Arsenault, FAIA, NCARB, LEED-AP Disclaimer: This presentation was developed by

More information

Compliance to the IgCC. September 29, 2011

Compliance to the IgCC. September 29, 2011 Bringing Outcome-Based Compliance to the IgCC September 29, 2011 Outcome-Based Codes: Any code requirement or code enforcement mechanism based on actual outcomes in buildings after they have been occupied.

More information

2012 USGBC Central Florida Chapter LEEDership Awards Outstanding Green Building of the Year: Valencia College, Lake Nona Campus Valencia College s

2012 USGBC Central Florida Chapter LEEDership Awards Outstanding Green Building of the Year: Valencia College, Lake Nona Campus Valencia College s 2012 USGBC Central Florida Chapter LEEDership Awards Outstanding Green Building of the Year: Valencia College, Lake Nona Campus Valencia College s fifth campus the first new campus in 15 years is in Southeast

More information

GUIDE SPECIFICATION: DUCT LINER

GUIDE SPECIFICATION: DUCT LINER GUIDE SPECIFICATION: DUCT LINER This specification guide includes thermal & acoustical insulation for ductwork and air handling systems. This section is based on the format recommended by MICA (Midwest

More information

GLADYS VALLEY HALL. Materials & Resources Innovation & Design Process

GLADYS VALLEY HALL. Materials & Resources Innovation & Design Process Instructional Facility VeterinaryVeterinary MedicineMedicine Instructional Facility GOING FOR GOLD Valley Hall has achieved LEED Platinum certification. The Leadership in Energy and Environmental Design

More information

GREEN STAR NZ - Education 2009 MANAGEMENT CATEGORY WEIGHTING: 10% No. of Points Available

GREEN STAR NZ - Education 2009 MANAGEMENT CATEGORY WEIGHTING: 10% No. of Points Available MANAGEMENT CATEGY WEIGHTING: 0% MAN- Green Star NZ To encourage and recognise the engagement Up to three points are awarded where it can be demonstrated that professionals who can assist the project Accredited

More information

INTERIORS GREEN GLOBES FOR SUSTAINABLE INTERIORS. Green Globes for SUSTAINABLE GREEN GLOBES TECHNICAL REFERENCE MANUAL

INTERIORS GREEN GLOBES FOR SUSTAINABLE INTERIORS. Green Globes for SUSTAINABLE GREEN GLOBES TECHNICAL REFERENCE MANUAL GREEN GLOBES TECHNICAL REFERENCE MANUAL Green Globes for SUSTAINABLE SI INTERIORS GREEN GLOBES FOR SUSTAINABLE INTERIORS Technical Reference Manual Version 1.1 March 4th, 2016 2016 2016 Green Building

More information

DEMAND CONTROLLED VENTILATION (DCV) SYSTEMS

DEMAND CONTROLLED VENTILATION (DCV) SYSTEMS DEMAND CONTROLLED VENTILATION (DCV) SYSTEMS Mari-Liis Maripuu, PhD CIT Energy mari-liis.maripuu@cit.chalmers.se Swegon Air Academy, Portugal, 27 May 211 Outline Introduction Concept of a DCV system Adapting

More information

PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT. Construction requirements for LOWER LEVEL DEVELOPMENT. in residential dwellings

PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT. Construction requirements for LOWER LEVEL DEVELOPMENT. in residential dwellings PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Construction requirements for LOWER LEVEL DEVELOPMENT in residential dwellings January 2018 contents GENERAL INFORMATION... 3 BUILDING CODE REQUIREMENTS...

More information

88.2% 32% 23% WEITZ LABORATORY GOLD. PROJECT HIGHLIGHTS LEED Facts. of on-site generated construction waste was diverted from landfills.

88.2% 32% 23% WEITZ LABORATORY GOLD. PROJECT HIGHLIGHTS LEED Facts. of on-site generated construction waste was diverted from landfills. WEITZ LABORATORY GORDON MCKAY LABS BUILDING, 9 OXFORD STREET, CAMBRIDGE, MA 02138 LEED-CIV3.0 GOLD The Gordon McKay Laboratory of Applied Science (McKay) building, occupied and operated by the School of

More information

SECTION RESILIENT SHEET FLOORING

SECTION RESILIENT SHEET FLOORING SECTION 09 65 16 RESILIENT SHEET FLOORING SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1.

More information

QUALITY SUSTAINS YKK AP Guide to LEED v4 Certification

QUALITY SUSTAINS YKK AP Guide to LEED v4 Certification QUALITY SUSTAINS YKK AP Guide to LEED v4 Certification Entrances Storefronts Curtain Walls Sun Controls Windows Balcony Doors SUSTAINABLE BUILDING ENVELOPES We at YKK AP America Inc. (YKK AP) follow our

More information

SUSTAINABLE BUILDING DESIGN

SUSTAINABLE BUILDING DESIGN SUSTAINABLE BUILDING DESIGN LEED and HVAC How Trane can help. HVAC and LEED 2009 BUILDING DESIGN AND CONSTRUCTION (BD+C)... Building on its past success, the U.S. Green Building Council (USGBC), the nonprofi

More information

LABORATORIES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. A. Section Accessibility for People with Disabilities

LABORATORIES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. A. Section Accessibility for People with Disabilities 230540 LABORATORIES PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 013010 Accessibility for People with Disabilities B. Section 018120 Energy Guidelines C. Section 018130

More information

Information Technology Solutions. Indoor Air Quality Management Plan

Information Technology Solutions. Indoor Air Quality Management Plan Information Technology Solutions Indoor Air Quality Management Plan January 2010 Table of Contents Section Page 1. Introduction 4 2. District Indoor Air Quality Coordinator 4 3. District Indoor Air Quality

More information

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma LEED Green Building Certification The purpose of the LEED Green Building Rating is to provide a national standard that aims to improve environmental, health and economic performance of buildings using

More information

Technical Guide Towards Energy Smart HOTEL. Energy Sustainability Unit. Department of Building National University of Singapore.

Technical Guide Towards Energy Smart HOTEL. Energy Sustainability Unit. Department of Building National University of Singapore. Technical Guide Towards Energy Smart HOTEL Energy Sustainability Unit Department of Building National University of Singapore Sponsored by Table of Contents 1 Introduction 1.1 Aim 1.2 Overview of Energy

More information

CONSTRUCTION REQUIREMENTS

CONSTRUCTION REQUIREMENTS CONSTRUCTION REQUIREMENTS Note: The buildings on the UCCS campus are divided into two categories: General Fund and Auxiliaries. General Fund Buildings include academic and administrative functions. Auxiliary

More information

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates Kittitach Pichatwatana, and Fan Wang Abstract This paper examines the TAS computer

More information

PROFESSIONAL DESIGN MANUAL INDEX

PROFESSIONAL DESIGN MANUAL INDEX PROFESSIONAL DESIGN MANUAL INDEX DIVISION A--GENERAL PROJECT REQUIREMENTS... A2-A15 A.1 INTRODUCTION... A-2 A.2 CODES COMPLIANCE (VERIFY CITY REQUIREMENTS)... A-5 A.3 SPECIAL SUBSURFACE AND LAND CONDITIONS...

More information

2012 IBC Exit Systems

2012 IBC Exit Systems Accreditation Based on the 2012 International Building Code The International Code Council has been accredited as an Authorized Provider by the International Association for Continuing Education and Training

More information

HOW TO BUILD AN ENVIRONMENTALLY RESPONSIBLE HOME

HOW TO BUILD AN ENVIRONMENTALLY RESPONSIBLE HOME HOW TO BUILD AN ENVIRONMENTALLY RESPONSIBLE HOME How To Build An Environmentally Responsible Home Doing the right thing for the environment. We hear it all of the time. Many of us are committed, particularly

More information

Draft Indoor Air Quality Regulations

Draft Indoor Air Quality Regulations Department of Environment and Labour Occupational Health and Safety Division Draft Indoor Air Quality Regulations May, 2001 These draft regulations are being distributed for public comment. They do NOT

More information

Section Wood Grille Ceiling Panels

Section Wood Grille Ceiling Panels Section 095426 Wood Grille Ceiling Panels PART 1 GENERAL RELATED DOCUMENTS Drawings and general conditions of the Contract, including General and Supplementary Conditions and Division 1 Specification sections

More information

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION 3.1 Purpose of Thermal Load Estimation 3.2 Heating Load versus Cooling Load 3.3 Critical Conditions for Design 3.4 Manual versus Computer Calculations 3.5 Heating

More information

Building Air Tightness: Consultation Paper. Building Air Tightness Consultation Paper

Building Air Tightness: Consultation Paper. Building Air Tightness Consultation Paper Building Air Tightness Consultation Paper 1 Instructions We are seeking your written feedback on the proposed updates to Green Star Design & As Built and Green Star - Interiors. Your feedback is important

More information

City of High Point Airport Overlay District Noise Level Reduction Design Standards

City of High Point Airport Overlay District Noise Level Reduction Design Standards City of High Point Airport Overlay District Noise Level Reduction Design Standards Part A. Residential Design Standards for Zone 3 I. NOISE LEVEL REDUCTION (NLR) REQUIREMENT FOR ZONE 3. The City of High

More information

CALGREEN NON-RESIDENTIAL BUILDING Plan Submittal Checklist

CALGREEN NON-RESIDENTIAL BUILDING Plan Submittal Checklist CALGREEN NON-RESIDENTIAL BUILDING Plan Submittal Checklist VERSION 1.0 REVISED 12/19/16 New non-residential buildings shall be designed to include the green building mandatory measures specified in this

More information

2001 National Workshop on State Building Energy Codes July th, 2001 Burlington, Vermont

2001 National Workshop on State Building Energy Codes July th, 2001 Burlington, Vermont 2001 National Workshop on State Building Energy Codes July 16-19 th, 2001 Burlington, Vermont A Systems Engineering Approach to the Design of Energy and Resource Efficient Homes Presented By: Mark LaLiberte

More information

Indoor Air Quality (IAQ) Tailoring Lease Specifications S-852

Indoor Air Quality (IAQ) Tailoring Lease Specifications S-852 Indoor Air Quality (IAQ) Tailoring Lease Specifications S-852 June 2015 Table of Contents Printed with permission from authors...3 Introduction...4 Outside air distribution...4 Air contaminant source...6

More information