1 Signage Fabrication/Design Intent Drawings Pavilion A June 21, 2017
2 A G.1.02 PRIMARY LOGO - HORIZONTAL ABCDEFGHIJKLMNO PQRSTUVWXYZ abcdefghijklmnopqr stuvwxyz Univers 57 Condensed ABCDEFGHIJKLM NOPQRSTUVWXYZ abcdefghijklmnop qrstuvwxyz Univers B G.1.02 PRIMARY LOGO - VERTICAL C G.1.02 PROJECT FONTS PROJECT STANDARDS - PROJECT LOGOS BP-6.01 G.1.02 PAGE 1
3 UK BLUE PMS 540c ALTERNATE DARK BLUE PMS 280c MATHEWS PAINT #MP10147 SATIN FINISH USE THE COLOR FOR BACKGROUND COLOR FOR ADA PARKING SIGNS INTERIOR SIGNAGE BROWN SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 3M VINYL - TBD BLACK PMS PROCESS BLACK coated MATHEWS PAINT #MP23591 SATIN FINISH 3M VINYL - BLACK WHITE 3M VINYL REFLECTIVE WHT-680CR (REMOVABLE) 3M-ANTIQUE WHT # MATHEWS PAINT #MP04473 SATIN FINISH PARKING GREEN PMS 362c P MATHEWS PAINT #MP13427 SATIN FINISH 3M TRANSLUCENT VINYL- LIME GREEN # REFLECTIVE RED VINYL 3M VINYL RED EMERGENCY RED PMS- 186c E MATHEWS ROSE SCARLET PAINT #MP20160 (SATIN) REQUIRES WHT. PRIMER BRUSHED ALUMINUM BRUSHED WITH A SATIN FINISH AUTOMOTIVE CLEAR COAT SAMPLE WILL BE REQUIRED PAVILION A ICON VINYL A 3M REFLECTIVE VINYL WHITE PAVILION HA ICON VINYL HA 3M REFLECTIVE VINYL WHITE PAVILION CC ICON VINYL CC 3M REFLECTIVE VINYL WHITE PAVILION H ICON VINYL H 3M REFLECTIVE VINYL WHITE PAVILION G ICON VINYL G 3M REFLECTIVE VINYL WHITE PAVILION WH ICON VINYL WH 3M REFLECTIVE VINYL WHITE NOTE THESE BLOCKS ARE A COMPUTER REPRESENTATION OF THE COLORS. AS SUCH THEY ARE ONLY A CLOSE APPROXIMATION OF THE ACTUAL COLORS. PLEASE REFER TO THE ACTUAL PANTONE SWATCHES FOR A MORE ACCURATE COLOR MATCH. NOTE ALTERNATIVES TO THE 3M VINYL SYSTEM WILL REQUIRE THAT THE FABRICATOR SUBMIT 6" SQUARE SAMPLES FOR APPROVAL. ALSO NOTE THAT ANY SUCH MATERIALS MUST HAVE A COMPARABLE WARRANTY. NOTE THAT PER THE GENERAL SPECIFICATIONS THE SIGN FABRICATOR IS TO SUBMIT FOUR (4) 6"X6" SAMPLES OF ALL ACTUAL MATERIAL, PAINT, OR VINYL ON THE SPECIFIC SUBSTRAIGHT TO BE USED FOR EACH DIFFERENT FINISH SURFACE. NOTE THAT ALL PAINTED ELEMENTS ARE TO HAVE A CLEAR, SATIN FINISH, AUTOMOTIVE GRADE, PROTECTIVE CLEAR COATING A G.1.03 PROJECT COLOR PALETTE B G.1.03 NOTED AS LEFT IN THE MESSAGE SCHEDULE NOTED AS UP/L UP LEFT IN THE MESSAGE SCHEDULE NOTED AS UP IN THE MESSAGE SCHEDULE NOTED AS UP/R UP RIGHT IN THE MESSAGE SCHEDULE NOTED AS RIGHT IN THE MESSAGE SCHEDULE NOTED AS DOWN IN THE MESSAGE SCHEDULE ARROW DESCRIPTIONS C G.1.03 INDICATES THE SIGN TYPE TYP A.1A.000 INDICATES THE BUILDING IN WHICH THE SIGN IS LOCATED. IN THIS CASE A STANDS FOR BUILDING A INDICATES THE QUADRANT OF THE PLAN ON WHICH THE SIGN IS LOCATED TYPICAL LOCATION PLAN LABEL INDICATES THE LEVEL ON WHICH THE SIGN IS LOCATED INDICATES THE SIGN S NUMBER ON THAT LEVEL IN THAT PARTICULAR QUADRANT PROJECT STANDARDS - FONTS, COLORS, GENERAL BP-6.01 G.1.03 PAGE 2
4 UK HealthCare Pavilion A Typical Elevator Lobby Level Artwork Panel (LEV) Interior Signage Design Intent Drawings scale: 1/= 1'-0" Typical Elevator Lobby Level Artwork Panel (LEV) 6'-w x 7'-h printed canvas or wallpaper graphic applied to recessed wall. Image/Art files will be provided UK HealthCare plan view 1'-6" 3'- R19'-1 1/ 3'- NOTE: Lighting and cove details are by others NOTE: Fabricator is to field verify all dimensions prior to fabrication NOTE: Fabricator is to provide minimum of three 8 1/2 x 11 printed, finished material samples for approval prior to fabrication 6'- 7'- 1 TYPICAL ELEVATOR LOBBY LEVEL ARTWORK PANEL (LEV) A832 SCALE: 1/ = 1'-0" TYPICAL ELEVATOR LOBBY LEVEL ARTWORK PANEL (PUBLIC LEVEL) LEV PAGE 3
5 UK HealthCare Pavilion A Typical Elevator Lobby Directional Plaque (PLQ) Interior Signage Design Intent Drawings scale: 1/= 1'-0" Typical Elevator Lobby Directional Plaque (PLQ) 2'-0"w x 2'-h Brushed aluminum panels with chamfered edges 1/ Brushed aluminum (horizontal grain) plan view 1'-6" 3'- R19'-1 1/ 3'- NOTE: Lighting and cove details are by others NOTE: Fabricator is to field verify all dimensions prior to fabrication 1'-0" 1'-0" 2 1 / 1 1 / Brushed aluminum letters cut out of the top of the aluminum panel (refer to message schedule for messages) 2'-0" 1 1 / 2 1 / 1 1 / 1 1 / 1/ Brushed aluminum panel with chamfered edges which are to be finished to match and etched and filled text and arrows that are a minimum of 1/16" deep. Panel is raised off of the wall surface. (refer to message schedule for messages) 1/ Brushed aluminum (horizontal grain) 2'-0" 2'-0" 4'-0" 1 TYPICAL ELEVATOR LOBBY DIRECTIONAL PLAQUE (PLQ) A832 SCALE: 1/ = 1'-0" TYPICAL ELEVATOR LOBBY DIRECTIONAL PLAQUE (PUBLIC LEVEL) PLQ PAGE 4
6 UK HealthCare Pavilion A Public Large Wall Mounted Directory (DRL) Interior Signage Design Intent Drawings scale: = 1'-0" plan view PAINTED ALUMINUM HEADER PANEL SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH BRUSHED ALUMINUM DIMENSIONAL BAND Brushed aluminum (horizontal grain) 1/ THICK BRUSHED ALUMINUM LETTERS WITH BEVELED EDGES ATTACHED FROM INSIDE THE HEADER WITH THREADED MECH FASTENERS AS REQUIRED.. Brushed aluminum (horizontal grain) PAINTED ALUMINUM HEADER PANEL SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH BRUSHED ALUMINUM DIMENSIONAL BAND - REMOVABLE FOR ACCESS TO PLATES AND DIRECTORY PANEL. SCREWED IN PLACE FROM ABOVE WITH COUNTERSUNK MECH FASTENERS FINISHED TO MATCH. Brushed aluminum (horizontal grain) ETCHED, BRUSHED ALUMINUM NAME PLATES Brushed aluminum (horizontal grain) BRUSHED ALUMINUM TRACK/DIVIDERS Brushed aluminum (vertical grain) BRUSHED ALUMINUM DIMENSIONAL BAND Brushed aluminum (horizontal grain) PAINTED ALUMINUM LOWER PANEL SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH NOTE: The directories have already been fabricated and are in storage at UKHC The only elements that need to be fabricated are the Etched Brushed Aluminum Name Plates NOTE: FABRICATOR IS TO FIELD VERIFY ALL DIMENSIONS, MATERIALS AND FABRICATION METHOD OF EXISTING DIRECTORIES PRIOR TO FABRICATION 3 PUBLIC LARGE WALL MOUNTED DIRECTORY (DRL) A832 SCALE: = 1'-0" LARGE WALL MOUNTED DIRECTORY (PUBLIC LEVEL) DRL PAGE 5
7 UK HealthCare Pavilion A Pin-Mounted Letters (LTR) Interior Signage Design Intent Drawings scale: = 1'-0" Pin-Mounted Letters (LTR) 1/ thick brushed aluminum letters with beveled edges Brushed aluminum (horizontal grain) Mounted with threaded pins and double-sided silicon tape NOTE: Sizes will vary based on application and message 10" PIN-MOUNTED LETTERS (PUBLIC LEVEL) LTR PAGE 6
8 UK HealthCare Pavilion A Public Pedestrian Overhead Directional (ODS) Interior Signage Design Intent Drawings scale: = 1'-0" Brushed aluminum rounded support rods which main message panel is secured to ceiling with C L 4'-0" C L CEILING 1 1 / 1/ 6'-0" 5'-6" TBD 2 1 / 2 1 / Brushed aluminum u-channel mounting bracket all edges are to be finished to match 1'-6" Text TBD Text TBD Pavilion A 1 1 / 1 1 / 1 1 / 3/16" 3/16" Resin coated, primed and painted PVC central panel with 3/16" beveled edges on all outside edges. All edges to be smooth and finished to match front and back panel faces. Public Pedestrian Overhead Directional (ODS) NOTE: This can be a One or Two Sided Sign. Text is always centered. 6'-0"w x 1'-6"h plaque with.1875 beveled edged face panel Reflective Vinyl Text 5'-3 1 / Text TBD Text TBD Pavilion A 5'-6"w x 2 1/h x 1 1/d brushed aluminum u-channel mounting bracket (horizontal grain) dia x TBD"h brushed aluminum rounded support rods TBD Reflective vinyl text CEILING Waiting / Sala de Espera Elevators / Acensor Pavilion A Patient Rooms A Pavilion A Waiting / Sala de Espera Elevators / Acensor Patient Rooms A Pavilion A scale 1/ = 1'-0" PEDESTRIAN OVERHEAD DIRECTIONAL (PUBLIC LEVEL) ODS PAGE 7
9 UK HealthCare Pavilion A Public Pedestrian Overhead Directional (ODS) Interior Signage Design Intent Drawings scale: = 1'-0" Brushed aluminum rounded support rods which main message panel is secured to ceiling with C L C L 4'-0" 1 1 / 1 1 / CEILING 1 1 / 1/ 6'-0" 5'-6" TBD 2 1 / 2 1 / 1 Brushed aluminum u-channel mounting bracket all edges are to be finished to match Staff Only Beyond This Point 3 1 / 3/16" 3/16" Resin coated, primed and painted PVC central panel with 3/16" beveled edges on all outside edges. All edges to be smooth and finished to match front and back panel faces. Reflective Vinyl Text 5'-9" Public Pedestrian Overhead Directional (ODS) Staff Only Beyond This Point NOTE: This can be a One or Two Sided Sign. Text is always centered. 6'-0"w x 1h plaque with.1875 beveled edged face panel 5'-6"w x 2 1/h x 1 1/d brushed aluminum u-channel mounting bracket (horizontal grain) dia x TBD"h brushed aluminum rounded support rods TBD Reflective vinyl text scale 1/ = 1'-0" PEDESTRIAN OVERHEAD DIRECTIONAL (PUBLIC LEVEL) ODS PAGE 8
10 UK HealthCare Pavilion A Back of House Overhead Directional (SOD) Interior Signage Design Intent Drawings scale: = 1'-0" 1 1 / CEILING 1'- 1'- Text TBD Text TBD Text TBD 1 1 / 1 1 / R Painted aluminum message panel Reflective Vinyl Text Back of House Overhead Directional (SOD) Text TBD Text TBD Text TBD NOTE: This can be a One or Two Sided Sign. Text is always centered. w x 1'-h x 1/8"t painted aluminum message panel Reflective vinyl text TBD CEILING Tower 100 Patient Rooms A Patient Rooms A OVERHEAD DIRECTIONAL (BACK OF HOUSE) scale 1/ = 1'-0" SOD PAGE 9
11 UK HealthCare Pavilion A Back of House Overhead Directional (SOD) Interior Signage Design Intent Drawings scale: = 1'-0" 1 1 / CEILING 11 1 / 11 1 / Text TBD Text TBD 1 1 / R Painted aluminum message panel Reflective Vinyl Text Back of House Overhead Directional (SOD) Text TBD Text TBD NOTE: This can be a One or Two Sided Sign. Text is always centered. w x 11 1/h x 1/8"t painted aluminum message panel Reflective vinyl text TBD CEILING Tower 100 Patient Rooms A OVERHEAD DIRECTIONAL (BACK OF HOUSE) scale 1/ = 1'-0" SOD PAGE 10
12 UK HealthCare Pavilion A Public Typical Blade Sign (BLD) Interior Signage Design Intent Drawings scale: = 1'-0" 1 1 / 3/8" 3/16" 3/16" Brushed aluminum rounded support rods which main message panel is secured to wall with 3 1 / 1'- 1'-5 1 / 2 3 /8" 1 1 / Public Typical Blade Sign (BLD) NOTE: This is a Two Sided Sign. Text is always justified to the outside edge. 1'-w x 1'-5 1/h plaque with.1875 beveled edged face panel 1 3 / Staff Elevator 1'-5 1 / 1'-5 1 / 1'-2 3 / 1 1 / w x 1'-5 1/h brushed aluminum mounting plate (vertical grain) 1 1/dia x 3 l brushed aluminum rounded support rods Reflective vinyl text Reflective Vinyl Text 1 1 / 1 1 / 3 1 / 3 1 / outside edge elevation Resin coated, primed and painted PVC central panel with 3/16" beveled edges on all outside edges except edge closest to wall. All edges to be smooth and finished to match front and back panel faces. Brushed aluminum mounting plate all edges are to be finished to match Staff Elevator 1'-5 1 / C L 7 1 / 7 1 / 6" TBD Women s Restroom 1'-5 1 / elevation with icon graphic example scale 1/ = 1'-0" TYPICAL BLADE SIGN (PUBLIC LEVEL) BLD PAGE 11
13 UK HealthCare Pavilion A Back of House Typical Blade Sign (SBD) Interior Signage Design Intent Drawings scale: = 1'-0" 1'-6" Back of House Typical Blade Sign (SBD) NOTE: This can be a One or Two Sided Sign. Text is always justified to the outside edge. 3 1 / 1'-6"w x 1'-h x 1/8"t painted aluminum message panel. Screw heads to be painted to match message panel. screw heads to be painted to match aluminum message panel 1 1 / A Service Reflective vinyl text 1'- 1'- Elevators Reflective Vinyl Text R plan view Painted aluminum message panel outside edge elevation A Service Elevators 1'-6" 7 1 / C L 10 1 / 6" TBD Women s Restroom 1'- elevation with icon graphic example scale 1/ = 1'-0" TYPICAL BLADE SIGN (BACK OF HOUSE) SBD PAGE 12
14 (Printed Paper Insert) RESIDENT WORKROOM A UK HealthCare Pavilion A Primary Room Identifier (RID) 1/ 1/8" spacer 1/8" painted clear acrylic face panel 8 1 / 1/8" spacer 1/8" painted clear acrylic face panel 1/ Primary Room Identifier (RID) 8.5"w x 9"h plaque with.125 beveled edged face panel 1/8" clear acrylic face panel 1 3 / 1/8" right sided paper insert void with diameter thumb void. The increased depth and thumb void will help with daily updating of various inserts. 9" 1 3 /8" 5/8" A FIRST LINE TEXT Raised 1/3 Text with masked areas for the insert clear window. 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 1/ 4 1 / insert window Message TBD (Printed Paper Insert) 7 3 / Ø insert access void C L 2 1/ paper insert void 2 1 / Message TBD (Printed Paper Insert) 1 1 / RESIDENT WORKROOM A / 8" right side A FIRST LINE TEXT Message TBD 2 1/ paper insert void insert window A insert window 8 1/ paper insert void PRIMARY ROOM IDENTIFIER (PUBLIC LEVEL) scale 1/ = 1'-0" RID PAGE 13
15 RESIDENT WORKROOM A UK HealthCare Pavilion A Primary Room Identifier (RID) 1/8" spacer 8 1 / 1/8" spacer 1/ 1/8" face panel 1/8" face panel 1/ Primary Room Identifier (RID) 8.5"w x 9"h plaque with.125 beveled edged face panel 1 3 / Silk screened white text applied to 1/ back panel OPEN and OCCUPIED with window slider which can slide left and right horizontally. 57 Condensed 9" 4 1 / 1 3 /8" 5/8" 5/8" A FIRST LINE TEXT SECOND LINE TEXT Raised 1/3 Text 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 1 1/ slider window OPEN OCCUPIED 1/ 1 1 / RESIDENT WORKROOM A Silk Screened Text 57 Condensed window slider right side 5/8" A FIRST LINE TEXT SECOND LINE TEXT OPEN OCCUPIED 1 1/ slider window OPEN OCCUPIED 1/ window slider 1 1 / RESIDENT WORKROOM A Silk Screened Text 57 Condensed scale 1/ = 1'-0" PRIMARY ROOM IDENTIFIER (PUBLIC LEVEL) RID PAGE 14
16 A SOILED UTILITY UK HealthCare Pavilion A Primary Room Identifier (RID) 8 1 / 1/ Primary Room Identifier (RID) 8.5"w x 9"h plaque with.125 beveled edged face panel 9" 1 3 /8" 5/8" A SOILED UTILITY 1 3 / Raised 1/3 Text 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 4 1 / 2 1 / 3/8" 1 1 / A SOILED UTILITY 2 1 / 2 1 / Raised 1/3 Graphics A SOILED UTILITY scale 1/ = 1'-0" PRIMARY ROOM IDENTIFIER (PUBLIC LEVEL) RID PAGE 15
17 RESIDENT WORKROOM A UK HealthCare Pavilion A Primary Room Identifier (RID) 8 1 / 1/ Primary Room Identifier (RID) 8.5"w x 9"h plaque with.125 beveled edged face panel 9" 4 1 / 1 3 /8" 5/8" 5/8" A FIRST LINE TEXT SECOND LINE TEXT 1 3 / Raised 1/3 Text 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 3 1 / 3/8" RESIDENT WORKROOM A A FIRST LINE TEXT SECOND LINE TEXT scale 1/ = 1'-0" PRIMARY ROOM IDENTIFIER (PUBLIC LEVEL) RID PAGE 16
18 VISITORS: IF DOOR IS LOCKED, USED INTERCOM TO REQUEST ENTRY UK HealthCare Pavilion A Primary Room Identifier (RID) 8 1 / 1/ Primary Room Identifier (RID) 8.5"w x 9"h plaque with.125 beveled edged face panel 9" 6 5 /8" 1 3 / 5/8" 5/8" 5/8" 5/8" VISITORS: IF DOOR IS LOCKED, USED INTERCOM TO REQUEST ENTRY Raised 1/3 Text 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 3/8" VISITORS: IF DOOR IS LOCKED, USED INTERCOM TO REQUEST ENTRY VISITORS: IF DOOR IS LOCKED, USED INTERCOM TO REQUEST ENTRY scale 1/ = 1'-0" PRIMARY ROOM IDENTIFIER (PUBLIC LEVEL) RID PAGE 17
19 REPORT ROOM UK HealthCare Pavilion A Secondary Room Identifier (SID) Secondary Room Identifier (SID) 1/8" 8 1 / 8.5"w x h plaque 5/8" 5/8" TBD REPORT ROOM Raised 1/3 Text 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH TBD scale 1/ = 1'-0" SECONDARY ROOM IDENTIFIER (PUBLIC LEVEL) SID PAGE 18
20 (8 1/ x 1 Printed Paper Insert) ACUTE CARE VISITOR GUIDELINES UK HealthCare Pavilion A Information with Insert (INFIST) Interior Signage Design Intent Drawings scale: = 1'-0" 1/ 1/8" spacer 1/8" painted clear acrylic face panel 9" 1/8" spacer 1/8" painted clear acrylic face panel 1/ Information with Insert (INFIST) 5/8" ACUTE CARE VISITOR GUIDELINES Raised 1/3 Text ACUTE CARE VISITOR GUIDELINES 9"w x 1'-"h plaque with.125 beveled edged face panel 1/8" clear acrylic face panel 1/8" right sided paper insert void with diameter thumb void. The increased depth and thumb void will help with daily updating of various inserts. Overall sign is painted SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH with masked areas for the insert clear window. 1'- 10 insert window Message TBD (8 1/ x 1 Printed Paper Insert) Ø insert access void C L 1 paper insert void 1 paper insert void Message TBD (8 1/ x 1 Printed Paper Insert) Ø insert access void C L 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 10 insert window 6 3 / 6 3 / 8 1/ insert window 1 3 /8" ACUTE CARE VISITOR GUIDELINES 1 3 /8" ACUTE CARE VISITOR GUIDELINES right side 8 1/ insert window 8 paper insert void ACUTE CARE VISITOR GUIDELINES Message TBD scale 1/ = 1'-0" INFORMATION WITH INSERT (PUBLIC LEVEL) INFIST PAGE 19
21 (Printed Paper Insert) A UK HealthCare Pavilion A Patient Room Identifier (PRI) 1/ 1/8" spacer 1/8" painted clear acrylic face panel graphic window 8 1 / 1/8" spacer 1/8" painted clear acrylic face panel 1/ Patient Room Identifier (PRI) 8.5"w x 7.5"h plaque with.125 beveled edged face panel 1/8" clear acrylic face panel has a second surface applied graphic (graphic provided by owner) 1 3 / 1/8" right sided paper insert void with diameter thumb void. The increased depth and thumb void will help with daily updating of the patient name inserts. 7 1 / 2 1/ graphic window insert window Message TBD (Printed Paper Insert) A Raised 1/3 Text Ø insert access void C L 2 1/ paper insert void with masked areas for the graphic and insert clear windows. 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 1/ 1 1 / A / 2 1 / Message TBD (Printed Paper Insert) right side 8" 2 1/ graphic 2 1/ graphic 2 1/ graphic window A A graphic window Message TBD 2 1/ paper insert void insert window A insert window 8 1/ paper insert void PATIENT ROOM IDENTIFIER (PUBLIC LEVEL) scale 1/ = 1'-0" PRI PAGE 20
22 UK HealthCare Pavilion A Patient Precautionary Signage Interior Signage Design Intent Drawings scale: = 1'-0" Check in at nurse station Welcome before entering room plan view section Dashed Red Line References Opening of Patient Precautionary Signage Beveled Front Edges 1 7 /8" (insert pocket) 1/8" Check in at nurse station Welcome before entering room 1 7 /8" 1 3 / 7 1 /8" Check in at nurse station Welcome before entering room Stacked Small/Large Reversible Warning and Patient Notice Inserts frame to hold up to 6 (two sided) digitally printed 1/3 bright white gravotac inserts for a total of 10 warnings/notices inserts slide in from right side inserts graphics TBD by hospital NOTE: Design uses same Stacked Small/Large Reversible Warning and Patient Notice Inserts as current interior patient alert insert signage within hospital 8 9 /16" (insert pocket) 8 5 /8" 11 5 /8" C L right side Patient Precautionary Signage mounted to patient room door with Frame Color: SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 7 3 /16" (insert pocket) 7 5 /8" Stacked Small/Large Reversible Warning and Patient Notice Inserts frame to hold up to 6 (two sided) digitally printed 1/3 bright white gravotac inserts for a total of 10 warnings/notices inserts slide in from right side inserts graphics TBD by hospital Check in at nurse station Welcome before entering room scale 1/ = 1'-0" PATIENT PRECAUTIONARY SIGNAGE (PUBLIC LEVEL) PREC PAGE 21
23 UK HealthCare Pavilion A Patient Precautionary Signage Interior Signage 2-Sided Digitally Printed Insert Detail Drawings scale: = 1'-0" Dashed Red Lines References Opening of Patient Precautionary Signage. Dashed Red Lines are not part of the graphic. Do Not Print Dashed Red Lines. 7 1 /8" Hearing Visually Impaired Impaired Use ASL Fall Risk Interpreter Fall Risk 6A small insert 1 side 1 small insert 1 side 2 Hard of Limited English Hearing Proficiency Fall Risk Use Interpreter 7A small insert 2 side 1 small insert 2 side 2 No BP or Fall Risk Sticks 8A small insert 3 side 1 small insert 3 side 2 R 6B 7B 8B Help us prevent the spread of infection! Droplet Precautions (In addition to Standard Precautions) Hospital Staff Perform Hand Hygiene before entering and upon leaving room Wear Standard Mask Close Door upon entering and exiting room Use Dedicated Equipment. Essential Transport Only. Standard Mask on Patient. Visitors Perform Hand Hygiene before entering and upon leaving room Wear Standard Mask Close Door upon entering and exiting room 1A 8 1 / Help us prevent the spread of infection! Contact Precautions (In addition to Standard Precautions) Hospital Staff Perform Hand Hygiene before entering and upon leaving room Wear Gown and Gloves Use Dedicated Equipment. Essential Transport Only. Visitors Perform Hand Hygiene before entering and upon leaving room 1B Help us prevent the spread of infection! Contact D/Airborne Precautions (In addition to Standard Precautions) Hospital Staff Wash Hands (Soap & Water) before entering and upon leaving room Wear Gown and Gloves Wear N95 Respirator Close Door upon entering and exiting room Use Dedicated Equipment. Essential Transport Only. Standard Mask on Patient, if possible. Use Sani Bleach Wipe. Visitors Wash Hands (Soap & Water) before entering and upon leaving room Help us prevent the spread of infection! Contact/Airborne Precautions (In addition to Standard Precautions) Hospital Staff Perform Hand Hygiene before entering and upon leaving room large insert 1 side 1 large insert 1 side 2 large insert 4 side 1 large insert 4 side 2 Wear Standard Mask Close Door upon entering and exiting room 4A Wear Gown and Gloves Wear N95 Respirator Close Door upon entering and exiting room Use Dedicated Equipment. Essential Transport Only. Standard Mask on Patient, if possible. Visitors Perform Hand Hygiene before entering and upon leaving room Wear Standard Mask Close Door upon entering and exiting room 4B L No BP or Sticks 9A 24-Hour Urine small insert 4 side 1 small insert 4 side 2 Welcome NPO 10A 10B small insert 5 side 1 small insert 5 side 2 9B Help us prevent the spread of infection! Contact D Precautions (In addition to Standard Precautions) Hospital Staff Wash Hands (Soap & Water) before entering and upon leaving room Wear Gown and Gloves Use Dedicated Equipment. Essential Transport Only. Use Sani Bleach Wipe. Visitors Wash Hands (Soap & Water) before entering and upon leaving room 2A Help us prevent the spread of infection! Airborne Precautions (In addition to Standard Precautions) Hospital Staff Perform Hand Hygiene before entering and upon leaving room Wear N95 Respirator Close Door upon entering and exiting room Use Dedicated Equipment. Essential Transport Only. Standard Mask on Patient, if possible. Visitors Perform Hand Hygiene before entering and upon leaving room Wear Standard Mask Close Door upon entering and exiting room 2B Room Closed for Maintenance large insert 2 side 1 large insert 2 side 2 large insert 5 side 1 large insert 5 side 2 5A 5B Check in at nurse station before entering room 11A Out of Service 11B small insert 6 side 1 small insert 6 side 2 Help us prevent the spread of infection! Contact / Droplet Precautions (In addition to Standard Precautions) Help us prevent the spread of infection! Contact D/Droplet Precautions (In addition to Standard Precautions) Dashed Red Lines References Opening of Patient Precautionary Signage. Dashed Red Lines are not part of the graphic. Do Not Print Dashed Red Lines. Hospital Staff Visitors Hospital Staff Visitors Stacked Small/Large Reversible Warning and Patient Notice Inserts 6 (two sided) digitally printed 1/3 bright white gravotac inserts for a total of 10 warnings/notices Perform Hand Hygiene before entering and upon leaving room Wear Gown and Gloves Wear Standard Mask Close Door upon entering and exiting room Use Dedicated Equipment. Essential Transport Only. Put Standard Mask on Patient, if possible. Perform Hand Hygiene before entering and upon leaving room Wear Standard Mask Close Door upon entering and exiting room 3A Wash Hands (Soap & Water) before entering and upon leaving room Wear Gown and Gloves Wear Standard Mask Close Door upon entering and exiting room Use Dedicated Equipment. Essential Transport Only. Standard Mask on Patient, if possible. Use Sani Bleach Wipe. Wash Hands (Soap & Water) before entering and upon leaving room Wear Standard Mask Close Door upon entering and exiting room large insert 3 side 1 large insert 3 side 2 3B PATIENT PRECAUTIONARY SIGNAGE (PUBLIC LEVEL) PREC PAGE 22
24 MEN UK HealthCare Pavilion A Public Restroom Identifier (RRS) 8 1 / 1/ 1 1 / Men s Restroom Identifier (RRS) 8.5"w x 11.5"h plaque with.125 beveled edged face panel 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 6" 11 1 / MEN Raised 1/3 Text and Icons 1/ MEN MEN scale 1/ = 1'-0" MEN S RESTROOM SIGN (PUBLIC LEVEL) RRS PAGE 23
25 WOMEN UK HealthCare Pavilion A Public Restroom Identifier (RRS) 8 1 / 1/ 1 1 / Women s Restroom Identifier (RRS) 8.5"w x 11.5"h plaque with.125 beveled edged face panel 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 6" 11 1 / WOMEN Raised 1/3 Text and Icons 1/ WOMEN WOMEN scale 1/ = 1'-0" WOMEN S RESTROOM SIGN (PUBLIC LEVEL) RRS PAGE 24
26 RESTROOM UK HealthCare Pavilion A Public Restroom Identifier (RRS) 8 1 / 1/ 2 1 / Unisex Restroom Identifier (RRS) 8.5"w x 11.5"h plaque with.125 beveled edged face panel 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 11 1 / 5 1 / RESTROOM Raised 1/3 Text and Icons 1/ RESTROOM RESTROOM scale 1/ = 1'-0" UNISEX RESTROOM SIGN (PUBLIC LEVEL) RRS PAGE 25
27 STAFF RESTROOM UK HealthCare Pavilion A Public Restroom Identifier (RRS) 8 1 / 1/ 2 1 / Staff Restroom Identifier (RRS) 8.5"w x 11.5"h plaque with.125 beveled edged face panel 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 11 1 / 5 1 / STAFF RESTROOM Raised 1/3 Text and Icons 1/ STAFF RESTROOM STAFF RESTROOM scale 1/ = 1'-0" STAFF RESTROOM SIGN (PUBLIC LEVEL) RRS PAGE 26
28 FAMILY RESTROOM UK HealthCare Pavilion A Public Restroom Identifier (RRS) 8 1 / 1/ 1 1 / Family Restroom Identifier (RRS) 8.5"w x 11.5"h plaque with.125 beveled edged face panel 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 4 3 / 11 1 / 5 1 / FAMILY RESTROOM Raised 1/3 Text and Icons 1/ FAMILY RESTROOM FAMILY RESTROOM scale 1/ = 1'-0" FAMILY RESTROOM SIGN (PUBLIC LEVEL) RRS PAGE 27
29 STAIRS UK HealthCare Pavilion A Public Stairwell Signage (SWS) 8 1 / 1/ 1 1 / Stairwell Signage (SWS) 8.5"w x 11.5"h plaque with.125 beveled edged face panel 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 6" 11 1 / STAIRS Raised 1/3 Text and Icons 1/ STAIRS STAIRS scale 1/ = 1'-0" STAIRWELL SIGNAGE (PUBLIC LEVEL) SWS PAGE 28
30 MEN UK HealthCare Pavilion A Back of House Restroom (SRR) 8 1 / 1/8" Men s Restroom Identifier (SRR) 8.5"w x 11.5"h plaque 1 1 / 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 6" 11 1 / MEN Raised 1/3 Text and Icons MEN MEN scale 1/ = 1'-0" MEN S RESTROOM SIGN (BACK OF HOUSE) SRR PAGE 29
31 WOMEN UK HealthCare Pavilion A Back of House Restroom (SRR) 8 1 / 1/8" Women s Restroom Identifier (SRR) 8.5"w x 11.5"h plaque 1 1 / 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 6" 11 1 / WOMEN Raised 1/3 Text and Icons WOMEN WOMEN scale 1/ = 1'-0" WOMEN S RESTROOM SIGN (BACK OF HOUSE) SRR PAGE 30
32 RESTROOM UK HealthCare Pavilion A Back of House Restroom (SRR) 8 1 / 1/8" Unisex Restroom Identifier (SRR) 8.5"w x 11.5"h plaque 2 1 / 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 11 1 / 5 1 / RESTROOM Raised 1/3 Text and Icons RESTROOM RESTROOM scale 1/ = 1'-0" UNISEX RESTROOM SIGN (BACK OF HOUSE) SRR PAGE 31
33 STAFF RESTROOM UK HealthCare Pavilion A Back of House Restroom (SRR) 8 1 / 1/8" Staff Restroom Identifier (SRR) 8.5"w x 11.5"h plaque 2 1 / 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH 11 1 / 5 1 / STAFF RESTROOM Raised 1/3 Text and Icons STAFF RESTROOM STAFF RESTROOM scale 1/ = 1'-0" STAFF RESTROOM SIGN (BACK OF HOUSE) SRR PAGE 32
34 REPORT ROOM UK HealthCare Pavilion A Back of House Room Identifier (SRI) Back of House Room Identifier (SRI) 1/8" 8 1 / 8.5"w x h plaque 5/8" 5/8" REPORT ROOM REPORT ROOM Raised 1/3 Text 1/3 (or 1/16") raised white text SHERWIN-WILLIAMS PAINT #SW0038 LIBRARY PEWTER SATIN FINISH REPORT ROOM scale 1/ = 1'-0" SERVICE LEVEL ROOM IDENTIFIER (BACK OF HOUSE) SRI PAGE 33
35 UK HealthCare Pavilion A Door Tag (DT) Interior Signage Design Intent Drawings scale: = Door Tag (DT) 1/8" 5/8" A w x h plaque Silk screened white text Silk Screened Text C L A scale 1/ = 1'-0" DOOR TAG (PUBLIC & BACK OF HOUSE) DT PAGE 34
1. Refer to SECTION SIGNS and reolace entire document with aftached new soecification. 5. Refer to Electrical Drawing E3.1
OTC REALIGNMENT - 8TH FLOOR ADDENDUM THREE June 25, 205 DRAWING CHANGES:. Refer to Mechanical Drawing M3. a. Revised: Fan Powered Terminal Unit Schedule. b. Revised: Variable Air Terminal Unit Schedule.
More informationa. Plaques with fixed panel. B. Related Sections: The following sections contain requirements that relate to this section:
SECTION 10 14 00 SIGNAGE PART 1 - GENERAL 1.1 DESCRIPTION A. This Section includes the following types of signs required for code compliance for the shell building (excludes user or tenant occupancy signage
More informationAPPENDIX SIGNAGE STANDARD DETAILS
APPENDIX I SIGNAGE STANDARD DETAILS INTERIOR SIGNAGE DETAILS INTERIOR ALPHA/NUMERIC ROOM NUMBER SEQUENCING GUIDELINES EXTERIOR LETTERING SIGNAGE DETAILS The following appendix includes information and
More informationADDENDUM NO. 2 PROJECT: COASTLINE COLLEGE
ADDENDUM NO. 2 Coast Community College District Purchasing Department PROJECT: COASTLINE COLLEGE Newport Learning Center Signage Project BID NO: 20 NOTICE TO BIDDERS ON THE ABOVE PROJECT: This addendum
More informationNEW ILLUMINATED LED SIGNAGE PAINTED STOREFRONT W/ VINYL GRAPHIC AND NEW LED SIGNAGE PAINT FINISHES (PROVIDE (2) COATS FOR ALL PAINTING) PT-1
MTA RR APPARATUS NEW ILLUMINATED LED SIGNAGE LIGHTWEIGHT REMOVABLE ALUMINUM PANEL FENCE 88 NORTH AVE CDR JOB NO. 60 NORTH AVE NORTH AVE CURRENT VIEW OF 88 NORTH AVENUE PROPOSED FACADE AT 88 NORTH AVENUE
More informationThe Catholic University of America Cardinal Station Washington, DC INTERIOR SIGNAGE GUIDELINES. January 21, 2009 (Revised)
The Catholic University of America Cardinal Station Washington, DC 20064 January 21, 2009 (Revised) OBJECTIVES The Interior Signage Guidelines for The Catholic University of America are intended to establish
More informationDIVISION 10 SPECIALTIES
DIVISION 10 SPECIALTIES A. INTERIOR SIGNAGE 1. Each room number shall be displayed with a wall mounted sign that is not less than 6 square placed 60" from its center to the finished floor and adjacent
More informationINTERIOR SIGNAGE MANUAL
INTERIOR SIGNAGE MANUAL ➊ Purpose ➋ Procedures ➌ ADA Requirements INTERIOR SIGNAGE MANUAL ➍ Text, Braille, Pictograms and Color ➎ Families of Interior Signage ➏ Mounting Guidelines ➐ Signage Diagrams ➊
More informationSECTION Interior Signage - Photochemically-Etched ADA or Informational Signage (SignEtch 1)
GUIDE SPECIFICATION Corporate Office: ASI Signage Innovations 8181 Jetstar Drive, Suite 100 Irving, Texas 75063 (214) 352-9140 voice (214) 352-9741 facsimile (800) ASI-SPEC [274-7732] www.asisignage.com
More informationTunnel Signage. Section B Tunnel Signage. Tunnel Signage Introduction B.1.1
Tunnel Signage B Section B Tunnel Signage B.1.1 Tunnel Signage Introduction B.2 Typical Signs & Usage B.2.1 Main Directional with Map B.2.2 Secondary Directional B.2.3 Map Only Directory B.2.4 Building
More informationDescription: The purpose of the section is to highlight the current applicable UMCP Design Standards for Interior Graphic signage.
Description: The purpose of the section is to highlight the current applicable UMCP Design Standards for Interior Graphic signage. Related Sections: TBD Effective Date: January 1, 2012 Applicable Standards:
More informationUniform Sign Plan (USP) Searstone 08-USP-009
Uniform Sign Plan (USP) Searstone 08-USP-009 A sign permit application must be submitted and a permit issued prior to installation of any sign, unless the LDO states that it is exempt from regulations.
More informationTechnical Specifications
Technical Drawing not currently available for this sign type P-CS-01 Campus Signature A Prominent external location to be negotiated with and approved by Property Unit P-CM-01 Campus Map Type A Wall Mounted
More informationUniform Sign Plan (USP) Weston Planned Unit Development (PUD) 86-USP-007
USP #: Location: Uniform Sign Plan (USP) Weston Planned Unit Development (PUD) 86-USP-007 A sign permit application must be submitted and a permit issued prior to installation of any sign that is not exempt
More informationSPECIFICATION GUIDE SLIDING CLOSET DOOR PART 1 - PRODUCT
SPECIFICATION GUIDE SLIDING CLOSET DOOR INTERIOR SLIDING GLASS DOOR PART 1 - PRODUCT 1.1 MANUFACTURER A. COXUSA 4755 E. Zinfandel Court, Suite D Ontario, California 91761 909.545.8900 eddie.coxusa@icloud.com
More informationSECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.
PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs. 1.2 PERFORMANCE REQUIREMENTS A. Structural
More informationPARKING GARAGE SIGNAGE DESIGN REQUIREMENTS
PARKING GARAGE SIGNAGE DESIGN REQUIREMENTS 1. Basic Identity System Elements: This is the master volume of the signage system and contains its entire background, along with the basic specifications for
More informationSECTION INTERIOR UNFRAMED SIGNS PHOTOPOLYMER BONDED TO ACRYLIC (InTouch )
GUIDE SPECIFICATION Corporate Office: ASI Signage Innovations 8181 Jetstar Drive, Suite 100 Irving, Texas 75063 (214) 352-9140 voice (214) 352-9741 facsimile (800) ASI-SPEC [274-7732] www.asisignage.com
More informationSECTION 10.0 WAYFINDING STANDARDS AND GUIDELINES
SECTION 10.0 WAYFINDING STANDARDS AND GUIDELINES 10.1. INTRODUCTION The University of Houston is a large urban campus that is largely accessed by its community through the automobile. Wayfinding is very
More informationGLASSWALL SPECIFICATIONS
GLASSWALL SPECIFICATIONS Series GL1 Individual, Glass Panels PRODUCT OVERVIEW: Top Supported Side Stack Individual, Omni-Directional Panels Manually Operated Maximum Opening Height: 10' 5 [.m] Maximum
More informationEnergy Saving LED Signs & Signals
Energy Saving LED Signs & Signals Free Marketing Tools About isigns Inc. Wholesale Sign Supplier isigns Inc. is a national wholesale sign supplier specializing in compact, energy saving LED illuminated
More informationMichigan State University Construction Standards PAGE
Construction Standards PAGE 101400-1 SECTION 101400 - PART 1 - GENERAL 1.1 M.S.U. ISSUES A. It is the objective of the University to provide all necessary signage to provide information for occupants,
More informationGLASS WALL SPECIFICATIONS
GLASS WALL SPECIFICATIONS PRODUCT OVERVIEW: Top Supported Center Stack Paired Panels Manually Operated Maximum Opening Height: 10'2 [3.1] Maximum Opening Width: Unlimited Select for Special Needs: Use
More informationPROPOSED EXTERIOR PROPOSED BLADE SIGN 8959 TYLER BLVD. MENTOR, OHIO PH FAX
PROPOSED INTERIOR STOREFRONT PROPOSED INTERIOR SIDE ELEVATION S T O R E # 0 4 0 4 3 A P A C H E M A L L 1 1 0 0 H W Y 1 4 - W E S T # 3 0 1 A P A C H E M A L L R O C H E S T E R, M N 5 5 9 0 2-2 1 9 1
More informationSECTION INTERIOR MODULAR INTERCHANGEABLE SIGNS PERFORM SERIES
GUIDE SPECIFICATION Corporate Office: ASI Signage Innovations 181 Jetstar Drive, Suite 100 Irving, Texas 75063 (214) 352-9140 voice (214) 352-9741 facsimile (800) ASI-SPEC [274-7732] www.asisignage.com
More informationSECTION INTERIOR SIGNS INFORM ADA PLAQUE SIGN
Corporate Office: ASI Signage Innovations 8181 Jetstar Drive Irving, Texas, 75063 (214) 352-9140 voice (214) 352-9741 facsimile (800) ASI-SPEC [274-7732] www.asisignage.com marketing@asisignage.com GUIDE
More informationSECTION Summit Phenolic Lockers (Solid Phenolic Lockers)
SECTION 10 51 00 Summit Phenolic Lockers (Solid Phenolic Lockers) Part 1-General 1.01 Summary A. Section includes: solid phenolic lockers solid phenolic benches 1.02 Submittals A. Submittals: Comply with
More informationINTERIOR DESIGN INTENT DRAWINGS - condensed version
INTERIOR DESIGN INTENT DRAWINGS - condensed version 8.10.2018 COMMENTS ADDED 11-11-16 A SILVER: MP18099 PLATINUM SPARKLE METALLIC VINYL: 3M SATIN ALUMINUM CHAMPAGNE: MP20051 SANDALWOOD METALLIC BIOHAZARD
More informationAPPENDIX B SIGNAGE STANDARDS
APPENDIX B SIGNAGE STANDARDS Post-merger, The University of Toledo has two signage design specifications. The former "Black & White" signage system (described in Part 1) is being phased out and gradually
More informationATTACHMENT 1 DRC Page 1 of 11
Page 1 of 11 Page 2 of 11 SITE MAP FENCE DESIGN RENDERING 2 Page 3 of 11 SITE MAP FENCE DESIGN w/ Optional wall blue color on building RENDERING 2a Page 4 of 11 Adeline Street Elevation SHOP THE STORE
More informationGLASSWALL SPECIFICATIONS
GLASSWALL SPECIFICATIONS Series GL Paired, Glass Panels PRODUCT OVERVIEW: Top Supported Center Stack Paired Panels Manually Operated Maximum Opening Height: 0' 5 [3.m] Maximum Opening Width: Unlimited
More informationDivision 10: Specialties
BSD Technical Standard Division 10: Specialties I. PURPOSE This is the Beaverton School District s (BSD s) Technical Standard for Specialties. This document shall be used as part of BSD s General Design
More informationDESIGN REVIEW BOARD MINUTES OF APRIL 16, 2014 Municipal Building Commission Room 151 Martin, Birmingham, Michigan
DESIGN REVIEW BOARD MINUTES OF APRIL 16, 2014 Municipal Building Commission Room 151 Martin, Birmingham, Michigan Minutes of the regular meeting of the ( DRB ) held Wednesday, April 16, 2014. Acting Chairperson
More informationIntroduction: Signage
Introduction: Signage Version /22 L3 Page.6. The Logo Library contains a special section with logos for signage applications. These files are in the EPS (Encapsulated PostScript) format and should be used
More informationSECTION SECURITY GRILLES 670 SERIES UPCOILING SECURITY GRILLE
SECTION 08 33 00 SECURITY GRILLES 670 SERIES UPCOILING SECURITY GRILLE Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on round
More informationSchedule C STANDARD Specifications
Schedule C STANDARD Specifications RTM Finished Home Specifications Name: Job #: Address: Phone: Standard Specifications FRAMING 2x6 exterior wall construction 3/8 OSB sheeting 2x4 interior wall construction
More informationInterior Doors with Aluminum Frames & Toilet Partitions Meeting Needs. Exceeding Expectations.
Designer Wall Systems Interior Doors with Aluminum Frames & Toilet Partitions Meeting Needs. Exceeding Expectations. Marlite Doors & Frames Marlite High Pressure Laminate (HPL) doors are attractive yet
More informationADDENDUM NUMBER 1: Portsmouth City Boiler Plant Improvements Project Bid Proposal # Issued: May 23, 2011
ADDENDUM NUMBER 1: Portsmouth City Boiler Plant Improvements Project Bid Proposal #43-11 Issued: May 23, 2011 This Addendum forms part of the original document marked: Portsmouth City Hall Boiler Plant
More informationSOLAR SHADING SYSTEMS - Manual Solar Shade SECTION ROLLER WINDOW SHADES
PART 1 - GENERAL SECTION 122413 - ROLLER WINDOW SHADES 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSTANDARDS FOR. Exterior Donor Signage
STANDARDS FOR Exterior Donor Signage STANDARDS FOR Exterior Donor Signage With the increased growth on campus, the university has prepared these standards for how best to acknowledge the generosity of
More informationUniform Sign Plan (USP) Millpond Village 00-USP-003
Uniform Sign Plan (USP) Millpond Village 00-USP-003 A sign permit application must be submitted and a permit issued prior to installation of a sign. USP identifier: 00-USP-003 Location: Kildaire Farm Road,
More informationEmbry-Riddle Aeronautical University Signage Specifications 03/25/2008
Embry-Riddle Aeronautical University Signage Specifications 03/25/2008 The following specifications are for the fabrication, painting of signs, graphics& installation of 4 (four) typical sign designs for
More informationINTERIOR SIGNAGE
101400 INTERIOR SIGNAGE PART 1: GENERAL 1.01 The Cornell University Interior Sign Standard has been developed to address the need for functional, flexible, and serviceable interior signs. The intent of
More informationUnleash Your Creative Potential with Slim-Panel Signage System
Macer Interior Modular Product olutions Unleash Your Creative Potential with lim-panel ignage ystem Macer Interior provides the freedom to unleash your creative ideas and achieve a precise look within
More informationSECTION INTERIOR UNFRAMED SIGNS PHOTOPOLYMER BONDED to ENGINEERED POLYESTER RESINS (Terra)
GUIDE SPECIFICATION Corporate Office: ASI Signage Innovations 8181 Jetstar Drive, Suite 100, Irving, Texas 75063 (214) 352-9140 voice (214) 352-9741 facsimile (800) ASI-SPEC [274-7732] www.asisignage.com
More informationSECTION PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS
SECTION 10 14 23 - PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationMASTER SIGN PLAN BRADFORD
MASTER SIGN PLAN 14-MSP-001 BRADFORD Unless exempt from regulation per Cary s Land Development Ordinance (LDO), a sign permit is required prior to the installation of all wall and ground signs. MSP identifier:
More informationSECTION LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS
Page 1 of 9 SECTION 10 2238.13 LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED FOLDING GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,
More information10155 Toilet Compartments
10155 Toilet Compartments This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or
More informationSECTION TRESPA ATHLON SOLID COMPOSITE CASEWORK
SECTION 064115 TRESPA ATHLON SOLID COMPOSITE CASEWORK PART 1 GENERAL 1.01 SECTION INCLUDES A. Solid composite casework. 1.02 RELATED SECTIONS A. Documents affecting work in this section includes but is
More informationSECTION PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS
SECTION 101423 - PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSERIES 487 CENTER GLAZED SLIDING DOOR WITH 1-1/2" TRIM
INSTALLATION INSTRUCTIONS SERIES 487 CENTER GLAZED SLIDING DOOR WITH 1-1/2" TRIM Phone: (800) 421-6144 Fax: (866) 921-0531 crlaurence.com usalum.com crl-arch.com 11M0200 GENERAL INSTALLATION NOTES Recommended
More informationModular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper
Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper Modular CABANA Kit 16 x 16 (6x6) Hipped Roof & Build-in Transoms Entry Key Lock Set (bright brass or dark bronze)
More informationR Scale: 3/32 = 1-0. Scale: 3/32 = 1-0
145-0 SIGN SCHEDULE A1 A2 A3 B C D E F G B G F A1 INTERNALLY ILLUMINATED CHANNEL LETTERS INTERNALLY ILLUMINATED CHANNEL LETTERS INTERNALLY ILLUMINATED CHANNEL LETTERS D/F INTERNALLY ILLUMINATED MONUMENT
More informationSDARNG Construct Break/Locker Room Brookings FMS#8, CFMO#FBR461653F
ADDENDUM No. 1 PROJECT SDARNG Construct Break/Locker Room Brookings FMS#8, CFMO#FBR461653F BID DATE 3:00 PM CT July 13, 2017 BID LOCATION Brookings Armory 300 5 th Street South, Brookings, SD 57006 ISSUE
More informationSECTION ALUMINUM STORM WINDOWS
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 08 51 69.11 ALUMINUM STORM WINDOWS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Also delete any other item or paragraph not applicable
More informationConstruction Standards PAGE
Construction Standards PAGE 102810-1 SECTION 102810 - PART 1 - GENERAL 1.1 M.S.U. ISSUES A. Mirrors will normally be provided at all lavatory locations. Provide full-length mirror on adjacent wall for
More informationSECTION WALL AND DOOR PROTECTION
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 10 26 00 WALL AND DOOR PROTECTION SPEC WRITER NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable to
More informationSECTION SOLID PHENOLIC PLASTIC TOILET PARTITIONS
PRODUCT SPECIFICATION SERIES 1080/1180 PART 1 - GENERAL 1.01 Work Included SECTION 10170 SOLID PHENOLIC PLASTIC TOILET PARTITIONS A. Toilet Compartments B. Urinal Screens C. Shower Dividers D. Dressing
More informationInsert Panel System. for Architectural Signage Modularity
System for Architectural Signage Modularity 3032 Walker Ridge Dr. NW Grand Rapids, MI 49544 Phone: (616) 784-0405 Toll Free: (877) 784-0405 Fax: (616) 784-0411 email: signcomp@signcomp.com www.signcomp.com
More informationSECTION ACCESS DOORS AND FRAMES
SECTION 08310 ACCESS DOORS AND FRAMES PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. [Fire rated] [and] [Non-fire rated] wall access panels. 2. [Fire rated] [and] [Non-fire rated] ceiling access
More informationFORM A: BID (See B8) 1. Project Title SUPPLY AND INSTALLATION OF INTERIOR AND EXTERIOR SIGNAGE MILLENIUM LIBRARY 251 DONALD STREET WPG. MAN.
Bid Opportunity No. 558-2005 Page 1 of 8 FORM A: BID (See B8) 1. Project Title SUPPLY AND INSTALLATION OF INTERIOR AND EXTERIOR SIGNAGE 2. Bidder Name of Bidder Street City Province Postal Code Facsimile
More informationNorthpointe Renovation EPN #1701 F/A Prroject #17027 September 8, 2017
SECTION 101423.16 - ROOM-IDENTIFICATION PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationUniversity of Illinois at Chicago Exterior Signage Standard
University of Illinois at Chicago Exterior Signage Standard Exterior Signage Production Requesting Process If requestor is a(n): Individual Person (Outside of a PPCON/CPPM Project) Individual requestors
More informationSECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware.
1 SECTION 08 4210 ALL GLASS ENTRANCES PART 1 - GENERAL 1.01 SUMMARY A. This section includes: 1. Vestibule doors matching entrance doors. 2. Sidelites. B. Related work in other sections: 1. Lock cylinders
More informationRESOLUTION NO
RESOLUTION NO. 04-2019 Authorizing an Amendment to the Final Development Plan for 160 West Wilson Bridge Road and Authorizing Variances (The Heights at Worthington Place). WHEREAS, William S. Adams has
More informationSECTION ALUMINUM STORM WINDOWS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 08 51 69.11 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable
More informationFABRICOIL BASIC January 10, 2006
FABRICOIL BASIC January 10, 2006 General Notes: This guide specification document is provided by Raynor Door for use by design professionals in preparing project specification documents for FABRICOIL BASIC
More informationSITE BRANDING. The Branding The Venue. Displayways specialise in graphics and branding, from production through to installation.
SITE BRANDING The Branding The Venue Located at the heart of London, Tobacco Dock extends over two levels, offering more than 16,000 sqm of impressive, blank canvas event space. With striking indoor and
More information/MOH BuyLine Architectural. Don t forget to call for more information. Mohawk Sign Systems, Inc. A Sign of Quality since 1946
10 14 00/MOH BuyLine 0645 Architectural 2008 Graphics Don t forget to call for more information. Mohawk Sign Systems, Inc. A Sign of Quality since 1946 A Sign of Quality Mohawk Sign Systems has been manufacturing
More informationNewfield Construction, Inc.
Newfield Construction, Inc. BULLETIN NO. 2 Date: August 10, 2018 Dillon Stadium Phase 2, Hartford, CT Clarifications 1. The bid date, place and time are unchanged by this bulletin. 2. Bidders are reminded
More informationSECTION PLASTIC LOCKERS. A. ADAAG - Americans with Disabilities Act, Accessibility Guidelines.
SECTION 10 51 26 PLASTIC LOCKERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Fully Assembled High Density Polyethylene Lockers B. High Density Polyethylene Benches 1.02 REFERENCES A. ADAAG - Americans with
More informationSECTION IMPACT RESISTANT WALL PROTECTION
SECTION 10265 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Impact-Resistant Wall Protection including Wall guards,
More informationSECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM
Page 1 of 6 SECTION 08 32 20 LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS SLIDING DOORS. SECTION INCLUDES OVERHEAD SLIDING TUBE ASSEMBLY, MOUNTING
More informationAugust, 2016 SECTION 09271
SECTION 09271 GYPSUM BOARD ** ACCESSORIES ** PART 1 - GENERAL 1.1 SUMMARY A. Related work specified elsewhere includes: 1. Rough carpentry. 2. Finish carpentry and millwork. 3. Metal support systems. 4.
More information2009 IBC Section 1024 Approved Luminous Egress Path Markings
2009 IBC Section 1024 Approved Luminous Egress Path Markings Where Required Buildings of Groups A (Assembly), B (Business), E (Education), I (Institutional), M (Mercantile) and R-1 (Residential transient
More informationInduro FRP. Wall Protection System. The Ultimate in Wall Protection for Hospitals, Senior Living and Clinics
Induro FRP Wall Protection System The Ultimate in Wall Protection for Hospitals, Senior Living and Clinics Healthcare Environment Demands Few walls are subjected to more potential abuse than vertical surfaces
More informationSCI-FAB Product Specifications. Casework Section 1. Part 1 General
SCI-FAB Product Specifications Casework Section 1 Part 1 General 1.1 SCOPE OF WORK Includes all factory fabricated stainless steel casework as required by the project drawings. 1.2 TYPICAL INCLUSIONS A.
More informationSECTION INTERIOR SIGNS JIGSAW SERIES
SPECIFICATION GUIDE Corporate Office:, Inc. 8181 Jetstar Drive Irving, Texas, 75063 (214) 352-9140 voice (214) 352-9741 facsimile (800) ASI-SPEC [274-7732] http://www.asisignage.com marketing@asisignage.com
More informationSECTION RESILIENT SHEET FLOORING
SECTION 09 65 16 RESILIENT SHEET FLOORING SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1.
More informationA. Flat corner wall-to-wall See page 8. C. Outside corner wall-to-wall See page 8. B. Inside corner kit wall-to-wall See page 7
System Overview These instructions review how to install drywall versions of TruGroove recessed corners. Please refer to layout drawings supplied by Philips Ledalite with these installation instructions.
More informationDoc
ANC-45 ACCORDION DOOR ACCORDION FOLDING PARTITIONS, WALLS OR DOORS GENERAL NOTES TO SPECIFIER: This specification section has been prepared to assist design professionals in the preparation of project
More informationGlass Care. Frame Cleaning
Frame Cleaning Glass Care Keeping your windows and doors clean means more than just the glass. Here are some helpful tips for cleaning your window and door frames effectively without damaging them. Vacuum
More informationThe City of Winnipeg NEWPCC Lab Renovation
Bid Opportunity 253-2011 Page 1 of 6 Part 1 General 1.1 SUMMARY.1 Work under this contract includes, but is not necessarily limited to:.1 Surface preparation of substrates as required for acceptance of
More informationMissouri S&T Bullman Showers Date: February 13, 2017 Project No SECTION PLASTIC SHOWER AND DRESSING COMPARTMENTS
SECTION 102116.19 - PLASTIC SHOWER AND DRESSING COMPARTMENTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More informationSECTION TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS. A. Solid composite phenolic toilet compartments and urinal screens.
SECTION 102113 TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Solid composite phenolic toilet compartments and urinal screens. 1.02 RELATED SECTIONS
More informationWCU ALUMNI TOWER MASONRY & ENVELOPE REPAIRS
SCO #: 8-8-0 TABLE OF CONTE COV DESCRIPTION COVER SHEET ALUMNI TOWER ELEVATIONS & PLAN VIEWS REPAIR DETAILS - M TO REPAIR DETAILS - TO M0 & C TO REPAIR DETAILS - A & F TO F VICINITY MAP ALUMNI TOWER ALUMNI
More informationExterior Wayfinding Signage Specifications and Details
Exterior Wayfinding Signage Specifications and Details 05/28/12 Sheet Number Sheet List Sheet Name 01 title and drawing list 02 typography, colours and pictograms 03 sign design - overview 04 sign design
More informationAnodized CArAbineer 3" x 1-1/2 " ntw 026 Blue ntw 027 Gold. blue
nch 092 2-1/2" x 1" x 1/2" Folded Red nch 093 2-1/2" x 1" x 1/2" Folded LaserBits metal Gift products feature special coatings that have been tested for optimum engraving performance. Rich and durable
More informationATTACHMENT 1 DRC Page 2 of 6
ATTACHMENT DRC 05-9-06 Page of 6 STREET Victory Avenue S. San Francisco, CA p: 650.87.958 f : 650-87-0 Clifford Kane, Project Manager 650..675 cliffordk@garnettsign.com CODE CONSIDERATIONS Project is situated
More informationTechnical Data Sheet Signature 842
Technical Data Sheet Signature 842 Signature 800 Series Features & Options Standard Features Manually-operated paired-panel movable partition STC 43 or 47 with gypsum board faces STC 49, 52, 53, or 55
More informationMODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS
MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS Ideal for applications requiring space division, visibility and security Used in bank lobbies, offices, conference areas, interior storefronts and arena skyboxes
More information3.5. Sign Types - Layout ST Graphics to be provided by Massport 3.0 SIGN TYPES - PARKING. Parking. Wall Mount - Identification
Volume : arking. Wall Mount - Identification DESCRITION: isle ID anels ST - LOCTION: Used on column panels on levels - MTERILS: Fabricated stainless steel panel with vinyl graphics. N/ N/ Graphics to be
More informationApplications (Rubber/Rubber) (Acrylic/Acrylic)
Polyethylene Mounting Foams R/R* A/A** Applications (Rubber/Rubber) (Acrylic/Acrylic) Mounting Interior 9223 9233 9226 9236 9228 9218 Mounting Exterior 9233 9236 9218 Trim Attachment 9218 *Rubber based
More informationGlassWall. Movable Partitions
GlassWall Movable Partitions The right choice has never been more clear. Combining the drama and beauty of glass with the functionality of operable partitions, Hufcor s GlassWall movable partitions allow
More informationLIGHTBLOCKS [FR] Fire Rated
DESCRIPTION LIGHTLOCKS Fire Rated rchitectural Resins [FR] offer architects and designers more creative freedom to transform space in a variety of venues where fire rated materials are required for finish
More informationInstructions for On-Site Coating of Vinyl Windows
www.aqua-diy.com Instructions for On-Site Coating of Vinyl Windows Aqua DIY D100 is a high performance heat reflective water-based coating. It has been shipped to you with a thickness suitable for manual
More informationSECTION MEDICATION CABINET. 1.1 SUMMARY A. Section Includes: 1. Medication cabinets with self-contained refrigerator and fixtures.
SECTION 12 35 70.21 MEDICATION CABINET SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Medication
More information5.0 BUILT FEATURES 5.5 AUDITORIUM (ASSEMBLY ROOM)
5.5 AUDITORIUM (ASSEMBLY ROOM) auditorium for presentations, seminars with projection room behind east wall access behind west wall (stage wall) to basement stairs and exterior 6 rubber base 1/4 mahogany
More information