1 LEED Rating System 4 th public comment draft INDOOR ENVIRONMENTAL QUALITY Includes: Building Design & Construction Interior Design & Construction Existing Buildings: Operations and Maintenance Neighborhood Development Credits shown in gray do not have substantive changes and are not open for public comment.

2 INDOOR ENVIRONMENTAL QUALITY (EQ)... 4 EQ Prerequisite: Minimum Indoor Air Quality Performance... 4 NC, CS, Schools, Retail, Data Centers, Warehouses & Distribution Centers, Hospitality... 4 Healthcare... 6 CI, Retail, Hospitality... 7 EBOM, Schools, Retail, Data Centers, Hospitality, Warehouses & Distribution Centers... 8 EQ Prerequisite: Environmental Tobacco Smoke Control NC, CS, Retail, Data Centers, Warehouses & Distribution Centers, Hospitality, Healthcare CI, Retail, Hospitality EBOM, Retail, Data Centers, Hospitality, Warehouses & Distribution Centers EBOM, Retail, Data Centers, Hospitality, Warehouses & Distribution Centers EQ Prerequisite: Minimum Acoustic Performance Schools EQ Prerequisite: Green Cleaning Policy EBOM, Schools, Retail, Data Centers, Hospitality, Warehouses & Distribution Centers EQ Credit: Indoor Air Quality Management Program EBOM, Schools, Retail, Data Centers, Hospitality, Warehouses & Distribution Centers EQ Credit: Enhanced Indoor Air Quality Strategies NC, CS, Schools, Retail, Data Centers, Warehouses & Distribution Centers, Hospitality, Healthcare, CI, Retail, Hospitality EBOM, Schools, Retail, Data Centers, Hospitality, Warehouses & Distribution Centers EQ Credit: Low-Emitting Interiors NC, CS, Schools, Retail, Data Centers, Warehouses & Distribution Centers, Hospitality, Healthcare, CI, Retail, Hospitality EQ Credit: Construction Indoor Air Quality Management Plan NC, CS, Schools, Retail, Data Centers, Warehouses & Distribution Centers, Hospitality, CI, Retail, Hospitality Healthcare EQ Credit: Indoor Air Quality Assessment NC, CS, Schools, Retail, Data Centers, Warehouses & Distribution Centers, Hospitality, Healthcare, CI, Retail, Hospitality EQ Credit: Thermal Comfort NC, Schools, Retail, Data Centers, Hospitality, CI, Retail, Hospitality Warehouses & Distribution Centers NC, Schools, Retail, Data Centers, Warehouses & Distribution Centers, Hospitality, CI, Retail, Hospitality Healthcare EBOM, Retail, Data Centers, Hospitality, Warehouses & Distribution Centers EQ Credit: Interior Lighting NC, Schools, Data Centers, Warehouses & Distribution Centers, Hospitality, CI, Hospitality Retail NC, Retail CI Healthcare EBOM, Retail, Data Centers, Hospitality, Warehouses & Distribution Centers

3 EQ Credit: Daylight NC, CS, Schools, Retail, Data Centers, Warehouses & Distribution Centers, Hospitality, Healthcare, CI, Retail, Hospitality EQ Credit: Daylight and Quality Views EBOM, Schools, Retail, Data Centers, Hospitality, Warehouses & Distribution Centers EQ Credit: Quality Views NC, CS, Schools, Retail, Data Centers, Hospitality, CI, Retail, Hospitality, Warehouses & Distribution Centers Healthcare EQ Credit: Acoustic Performance NC, Data Centers, Warehouses & Distribution Centers, Hospitality, CI, Hospitality Reverberation Time and Reverberant Noise Buildup Schools Healthcare EQ Credit: Green Cleaning Custodial Effectiveness Assessment EBOM, Schools, Retail, Data Centers, Hospitality, Warehouses & Distribution Centers EQ Credit: Green Cleaning Products and Materials EBOM, Schools, Retail, Data Centers, Hospitality, Warehouses & Distribution Centers EQ Credit: Green Cleaning Equipment EBOM, Schools, Retail, Data Centers, Hospitality, Warehouses & Distribution Centers EQ Credit: Integrated Pest Management EBOM, Schools, Retail, Data Centers, Hospitality, Warehouses & Distribution Centers EQ Credit: Occupant Comfort Survey EBOM, Schools, Retail, Data Centers, Hospitality, Warehouses & Distribution Centers

4 INDOOR ENVIRONMENTAL QUALITY (EQ) EQ PREREQUISITE: MINIMUM INDOOR AIR QUALITY PERFORMANCE Required BD&C This prerequisite applies to New Construction Core & Shell Schools Retail Data Centers Warehouses & Distribution Centers Hospitality Healthcare ID&C This prerequisite applies to Commercial Interiors Retail Hospitality EB: O&M This prerequisite applies to Existing Buildings: Operations & Maintenance EB:O&M Schools EB:O&M Retail EB:O&M Data Centers EB:O&M Hospitality EB:O&M Warehouses & Distribution Centers Intent To contribute to the comfort and well-being of building occupants by establishing minimum standards for indoor air quality (IAQ). Requirements NC, CS, SCHOOLS, RETAIL, DATA CENTERS, WAREHOUSES & DISTRIBUTION CENTERS, HOSPITALITY Meet the requirements for both ventilation and monitoring. Ventilation Mechanically Ventilated Spaces For mechanically ventilated spaces (and for mixed-mode systems when the mechanical ventilation is activated), determine the minimum outdoor air intake flow for mechanical ventilation systems using the ventilation rate procedure from ASHRAE or a local equivalent, whichever is more stringent. Option 1. ASHRAE Standard Meet the minimum requirements of ASHRAE Standard , Sections 4 7, Ventilation for Acceptable Indoor Air Quality (with errata), or a local equivalent, whichever is more stringent. 4

5 Option 2. CEN Standards EN and EN Projects outside the United States may instead meet the minimum requirements of Annex B of Comité Européen de Normalisation (CEN) Standard EN , Indoor environmental input parameters for design and assessment of energy performance of buildings addressing indoor air quality, thermal environment, lighting and acoustics; and the requirements of CEN Standard EN , Ventilation for nonresidential buildings, Performance requirements for ventilation and room conditioning systems, excluding Section 7.3, Thermal environment; 7.6, Acoustic environment; A.16; and A.17. Naturally Ventilated Spaces For naturally ventilated spaces (and for mixed-mode systems when the mechanical ventilation is inactivated), determine the minimum outdoor air opening and space configuration requirements using the natural ventilation procedure from ASHRAE Standard or a local equivalent, whichever is more stringent. Confirm that natural ventilation is an effective strategy for the project by following the flow diagram in the Chartered Institution of Building Services Engineers (CIBSE) Applications Manual AM10, March 2005, Natural Ventilation in Nondomestic Buildings, Figure 2.8, and meet the requirements of ASHRAE Standard , Section 4, or a local equivalent, whichever is more stringent. All Spaces The indoor air quality procedure defined in ASHRAE Standard may not be used to comply with this prerequisite. Monitoring Mechanically Ventilated Spaces For mechanically ventilated spaces (and for mixed-mode systems when the mechanical ventilation is activated), monitor outdoor air intake flow as follows: For variable air volume systems, provide a direct outdoor airflow measurement device capable of measuring the minimum outdoor air intake flow. This device must measure the minimum outdoor air intake flow with an accuracy of +/ 10% of the design minimum outdoor airflow rate, as defined by the ventilation requirements above. An alarm must indicate when the outdoor airflow value varies by 15% or more from the outdoor airflow setpoint. For constant-volume systems, balance outdoor airflow to the design minimum outdoor airflow rate defined by ASHRAE Standard (with errata but without addenda 2 ), or higher. Install a current transducer on the supply fan, an airflow switch, or similar monitoring device. Naturally Ventilated Spaces For naturally ventilated spaces (and for mixed-mode systems when the mechanical ventilation is inactivated), comply with at least one of the following strategies. Provide a direct exhaust airflow measurement device capable of measuring the exhaust airflow. This device must measure the exhaust airflow with an accuracy of +/ 10% of the design minimum exhaust airflow rate. An alarm must indicate when airflow values vary by 15% or more from the exhaust airflow setpoint. Provide automatic indication devices on all natural ventilation openings intended to meet the minimum opening requirements. An alarm must indicate when any one of the openings is closed during occupied hours. Monitor carbon dioxide (CO 2 ) concentrations within each thermal zone. CO 2 monitors must be between 3 and 6 feet (90 and 180 centimeters) above the floor and within the thermal zone. CO 2 monitors must have an audible or visual indicator or alert the building automation system if the sensed CO 2 concentration exceeds the setpoint by more than 10%. Calculate appropriate CO 2 setpoints using the methods in ASHRAE , Appendix C. CS only Mechanical ventilation systems installed during core and shell construction must be capable of meeting projected ventilation levels and monitoring based on the requirements of anticipated future tenants. Residential only 5

6 In addition to the requirements above, if the project building contains residential units, each dwelling unit must meet all of the following requirements. Unvented combustion appliances (e.g., decorative logs) are not allowed. Carbon monoxide monitors must be installed on each floor of each unit. All indoor fireplaces and woodstoves must have solid glass enclosures or doors that seal when closed. Any indoor fireplaces and woodstoves that are not closed combustion or power-vented must pass a backdraft potential test to ensure that depressurization of the combustion appliance zone is less than 5 Pa. Space- and water-heating equipment that involves combustion must be designed and installed with closed combustion (i.e., sealed supply air and exhaust ducting) or with power-vented exhaust, or located in a detached utility building or open-air facility. For projects in high-risk areas for radon, EPA Radon Zone 1 (or local equivalent for project outside the United States), design and construct any dwelling unit on levels one through four above grade with radon-resistant construction techniques. Follow the techniques prescribed in EPA Building Radon Out; NFPA 5000, Chapter 49; International Residential Code, Appendix F; CABO, Appendix F; ASTM E1465; or a local equivalent, whichever is most stringent. HEALTHCARE Meet the following requirements for both ventilation and monitoring. Ventilation Meet the minimum requirements of ASHRAE Standard , Sections 6 8, Ventilation of Health Care Facilities (with errata) or a USGBC-approved equivalent. To determine the minimum outdoor air intake flow for mechanical ventilation systems (and for mixedmode systems when the mechanical ventilation is activated), use the ventilation rates in ASHRAE Standard , Section 7; the requirements of the 2010 FGI Guidelines for Design and Construction of Health Care Facilities (Table 2.1 2); or a local equivalent, whichever is most stringent. For any area not covered in 170 or the FGI guidelines, follow ASHRAE 62.1 or a local equivalent, whichever is more stringent. To determine the minimum outdoor air opening and space configuration requirements for naturally ventilated spaces (and for mixed-mode systems when the mechanical ventilation is inactivated), use the natural ventilation procedure of ASHRAE Standard (with errata but without addenda 3 ) or a local equivalent, whichever is more stringent. Confirm that natural ventilation is an effective strategy for the project by following the flow diagram in Figure 2.8 of the Chartered Institution of Building Services Engineers (CIBSE) Applications Manual AM10, March 2005, Natural Ventilation in Nondomestic Buildings. Monitoring Mechanically Ventilated Spaces For mechanically ventilated spaces (and for mixed-mode systems when the mechanical ventilation is activated), provide a direct outdoor airflow measurement device capable of measuring the minimum outdoor air intake flow. This device must measure the minimum outdoor air intake flow with an accuracy of +/ 10% of the design minimum outdoor airflow rate defined by ASHRAE Standard (with errata). An alarm must alert staff whenever the outdoor airflow value varies by 15% or more from the outdoor airflow setpoint. Naturally Ventilated Spaces 6

7 For naturally ventilated spaces (and for mixed-mode systems when the mechanical ventilation is inactivated), comply with at least one of the following strategies. Provide a direct exhaust airflow measurement device capable of measuring the exhaust airflow with an accuracy of +/ 10% of the design minimum exhaust airflow rate. An alarm must indicate when airflow values vary by 15% or more from the exhaust airflow setpoint. Provide automatic indication devices on all natural ventilation openings intended to meet the minimum opening requirements. An alarm must indicate when any one of the openings is closed during occupied hours. Monitor carbon dioxide (CO 2 ) concentrations within each thermal zone. CO 2 monitors must be between 3 and 6 feet (90 and 180 centimeters) above the floor and within the thermal zone. CO 2 monitors must have an audible or visual indicator or alert the building automation system if the sensed CO 2 concentration exceeds the setpoint by more than 10%. Calculate appropriate CO 2 setpoints by using the methods in ASHRAE , Appendix C. CI, RETAIL, HOSPITALITY Meet the requirements for both ventilation and monitoring. Ventilation Mechanically Ventilated Spaces For mechanically ventilated spaces (and for mixed-mode systems when the mechanical ventilation is activated), chose one of the following cases. Case 1. Systems Able to Meet Required Outdoor Airflow Rates Determine the minimum outdoor air intake flow for mechanical ventilation systems using the ventilation rate procedure from ASHRAE or a local equivalent, whichever is more stringent. Option 1. ASHRAE Standard Meet the minimum requirements of ASHRAE Standard , Sections 4 7, Ventilation for Acceptable Indoor Air Quality (with errata), or a local equivalent, whichever is more stringent. Option 2. CEN Standards EN and EN Projects outside the United States may instead meet the minimum requirements of Annex B of Comité Européen de Normalisation (CEN) Standard EN , Indoor environmental input parameters for design and assessment of energy performance of buildings addressing indoor air quality, thermal environment, lighting and acoustics; and the requirements of CEN Standard EN , Ventilation for nonresidential buildings, Performance requirements for ventilation and room conditioning systems, excluding Section 7.3, Thermal environment; 7.6, Acoustic environment; A.16; and A.17. Case 2. Systems Unable to Meet Required Outdoor Airflow Rates If meeting the outdoor airflow rates in Case 1 is not feasible because of the physical constraints of the existing ventilation system, complete an engineering assessment of the system s maximum outdoor air delivery rate. Supply the maximum possible to reach the minimum setpoint in Case 1 and not less than 10 cubic feet per minute (5 liters per second) of outdoor air per person. Naturally Ventilated Spaces For naturally ventilated spaces (and for mixed-mode systems when the mechanical ventilation is inactivated), determine the minimum outdoor air opening and space configuration requirements using the natural ventilation procedure from ASHRAE Standard or a local equivalent, whichever is more stringent. Confirm that natural ventilation is an effective strategy for the project by following the flow diagram in the Chartered Institution of Building Services Engineers (CIBSE) Applications Manual AM10, March 2005, Natural Ventilation in Nondomestic Buildings, Figure 2.8 and meet the requirements of ASHRAE Standard , Section 4, or a local equivalent, whichever is more stringent. All Spaces 7

8 The indoor air quality procedure defined in ASHRAE Standard may not be used to comply with this prerequisite. Monitoring Case 1. Mechanically Ventilated Spaces For mechanically ventilated spaces (and for mixed-mode systems when the mechanical ventilation is activated), monitor outdoor air intake flow as follows: For variable air volume systems with an outdoor air intake in the project scope of work, provide a direct outdoor airflow measurement device capable of measuring the minimum outdoor air intake flow with an accuracy of +/ 10% of the design minimum outdoor airflow rate, as defined by the ventilation requirements above. An alarm must indicate when the outdoor airflow value varies by 15% or more from the outdoor airflow setpoint. For constant-volume systems included in the tenant scope of work, balance outdoor airflow to the design minimum outdoor airflow rate defined by ASHRAE Standard (with errata but without addenda), or higher. Install a current transducer on the supply fan, an airflow switch, or similar monitoring device. Case 2. Naturally Ventilated Spaces For naturally ventilated spaces (and for mixed-mode systems when the mechanical ventilation is inactivated), comply with at least one of the following. Provide a direct exhaust airflow measurement device capable of measuring the exhaust airflow with an accuracy of +/ 10% of the design minimum exhaust airflow rate. An alarm must indicate when airflow values vary by 15% or more from the exhaust airflow setpoint. Provide automatic indication devices on all natural ventilation openings intended to meet the minimum opening requirements. An alarm must indicate when any one of the openings is closed during occupied hours. Monitor carbon dioxide (CO 2 ) concentrations within each thermal zone. CO 2 monitors must be between 3 and 6 feet (90 and 180 centimeters) above the floor and within the thermal zone. CO 2 monitors must have an audible or visual indicator or alert the building automation system if the sensed CO 2 concentration exceeds the setpoint by more than 10%. Calculate appropriate CO 2 setpoints by using the methods in ASHRAE , Appendix C. EBOM, SCHOOLS, RETAIL, DATA CENTERS, HOSPITALITY, WAREHOUSES & DISTRIBUTION CENTERS ESTABLISHMENT Each air-handling unit in the building must comply with either Case 1 or Case 2. If some air-handling units can provide the outdoor airflow required by Case 1 and others cannot, those that can must do so. Mechanically Ventilated Spaces For mechanically ventilated spaces (and for mixed-mode systems when the mechanical ventilation is activated), chose one of the following: Case 1. Systems Able to Meet Required Outdoor Airflow Rates Option 1. ASHRAE Standard Meet the minimum requirements of ASHRAE Standard , Sections 4 7, Ventilation for Acceptable Indoor Air Quality (with errata but without addenda 3 ), or a local equivalent, whichever is more stringent. Modify or maintain each outdoor air intake, supply air fan, and ventilation distribution system to meet the outdoor air intake flow rates, using the ASHRAE ventilation rate procedure or a local equivalent, whichever is more stringent. Option 2. CEN Standards EN and EN Projects outside the United States may instead meet the minimum requirements of Annex B of Comité Européen de Normalisation (CEN) Standard EN , Indoor environmental input parameters for design and assessment of energy performance of buildings addressing indoor air quality, thermal environment, lighting and acoustics; and the requirements of CEN Standard EN , Ventilation 8

9 for nonresidential buildings, Performance requirements for ventilation and room conditioning systems, excluding Section 7.3, Thermal environment; 7.6, Acoustic environment; A.16; and A.17. Case 2. Systems Unable to Meet Required Outdoor Airflow Rates If meeting the outdoor airflow rates in Case 1 is not feasible because of the physical constraints of the existing ventilation system, complete an engineering assessment of the system s maximum outdoor air delivery rate. Supply the maximum possible to reach the minimum setpoint in Case 1 and not less than 10 cubic feet per minute (5 liters per second) of outdoor air per person. Naturally Ventilated Spaces For naturally ventilated spaces (and for mixed-mode systems when the mechanical ventilation is inactivated), determine the minimum outdoor air opening and space configuration requirements using the natural ventilation procedure from ASHRAE Standard or a local equivalent, whichever is more stringent. Confirm that natural ventilation is an effective strategy for the project by following the flow diagram in the Chartered Institution of Building Services Engineers (CIBSE) Applications Manual AM10, March 2005, Natural Ventilation in Nondomestic Buildings, Figure 2.8 and meet the requirements of ASHRAE Standard , Section 4, or a local equivalent, whichever is more stringent. All Spaces The indoor air quality procedure defined in ASHRAE Standard may not be used to comply with this prerequisite. PERFORMANCE Show compliance through measurements taken at the system level within five years of the end of the performance period. Implement and maintain an HVAC system maintenance program, based on ASHRAE , Section 8, or a local equivalent, whichever is more stringent, to ensure the proper operations and maintenance of HVAC components as they relate to outdoor air introduction and exhaust. 9

10 EQ PREREQUISITE: ENVIRONMENTAL TOBACCO SMOKE CONTROL Required BD&C This prerequisite applies to New Construction Core & Shell Schools Retail Data Centers Warehouses & Distribution Centers Hospitality Healthcare ID&C This prerequisite applies to Commercial Interiors Retail Hospitality EB:O&M This prerequisite applies to Existing Buildings: Operations & Maintenance EB:O&M Schools EB:O&M Retail EB:O&M Data Centers EB:O&M Hospitality EB:O&M Warehouses & Distribution Centers Intent To prevent or minimize exposure of building occupants, indoor surfaces, and ventilation air distribution systems to environmental tobacco smoke. Requirements NC, CS, RETAIL, DATA CENTERS, WAREHOUSES & DISTRIBUTION CENTERS, HOSPITALITY, HEALTHCARE Prohibit smoking inside the building. Prohibit smoking outside the building except in designated smoking areas located at least 25 feet (7.5 meters) from all entries, outdoor air intakes, and operable windows. The no-smoking policy also applies to spaces outside the property line used for business purposes. If the requirement to prohibit smoking within 25 feet (7.5 meters) cannot be implemented because of code, provide documentation of these regulations. Signage must be posted within 10 feet (3 meters) of all building entrances indicating the no-smoking policy. Residential only Option 1. No Smoking Meet the requirements above. 10

11 OR Option 2. Compartmentalization of Smoking Areas Prohibit smoking inside all common areas of the building. The prohibition must be communicated in building rental or lease agreements or condo or coop association covenants and restrictions. Make provisions for enforcement. Prohibit smoking outside the building except in designated smoking areas located at least 25 feet (7.5 meters) from all entries, outdoor air intakes, and operable windows. The no-smoking policy also applies to spaces outside the property line used for business purposes. If the requirement to prohibit smoking within 25 feet (7.5 meters) cannot be implemented because of code, provide documentation of these regulations. Signage must be posted within 10 feet (3 meters) of all building entrances indicating the no-smoking policy. Each unit must be compartmentalized to prevent excessive leakage between units: Weather-strip all exterior doors and operable windows in the residential units to minimize leakage from outdoors. Weather-strip all doors leading from residential units into common hallways. Minimize uncontrolled pathways for the transfer of smoke and other indoor air pollutants between residential units by sealing penetrations in the walls, ceilings, and floors and by sealing vertical chases (including utility chases, garbage chutes, mail drops, and elevator shafts) adjacent to the units. Demonstrate a maximum leakage of 0.23 cubic feet per minute per square foot (1.17 liters per second per square meter) at 50 Pa of enclosure (i.e., all surfaces enclosing the apartment, including exterior and party walls, floors, and ceilings). SCHOOLS Prohibit smoking on site. Signage must be posted at the property line indicating the no-smoking policy. CI, RETAIL, HOSPITALITY Locate the project in a building that prohibits smoking by all occupants and users both inside the building and outside the building except in designated smoking areas located at least 25 feet (7.5 meters) from all entries, outdoor air intakes, and operable windows. The no-smoking policy also applies to spaces outside the property line used for business purposes. If the requirement to prohibit smoking within 25 feet (7.5 meters) cannot be implemented because of code, provide documentation of these regulations. Signage must be posted within 10 feet (3 meters) of all building entrances indicating the no-smoking policy. EBOM, RETAIL, DATA CENTERS, HOSPITALITY, WAREHOUSES & DISTRIBUTION CENTERS ESTABLISHMENT Prohibit smoking in the building. Prohibit smoking outside the building except in designated smoking areas located at least 25 feet (7.5 meters) from all entries, outdoor air intakes, and operable windows. The no-smoking policy also applies to spaces outside the property line used for business purposes. 11

12 If the requirement to prohibit smoking within 25 feet (7.5 meters) cannot be implemented because of code, provide documentation of these regulations. Signage must be posted within 10 feet (3 meters) of all building entrances indicating the no smoking policy. Residential only Option 1. No Smoking Meet the requirements above. OR Option 2. Compartmentalization of Smoking Areas Prohibit smoking in all common areas of the building. The prohibition must be communicated in building rental or lease agreements or condo or coop association covenants and restrictions. Make provisions for enforcement. Prohibit smoking outside the building except in designated smoking areas located at least 25 feet (7.5 meters) from all entries, outdoor air intakes, and operable windows. The no-smoking policy also applies to spaces outside the property line used for business purposes. If the requirement to prohibit smoking within 25 feet (7.5 meters) cannot be implemented because of code, provide documentation of these regulations. Signage must be posted within 10 feet (3 meters) of all building entrances indicating the no-smoking policy. Each unit must be compartmentalized to prevent excessive leakage between units: Weather-strip all exterior doors and operable windows in the residential units to minimize leakage from outdoors. Weather-strip all doors leading from residential units into common hallways. Minimize uncontrolled pathways for the transfer of smoke and other indoor air pollutants between residential units by sealing penetrations in the walls, ceilings, and floors and by sealing vertical chases (including utility chases, garbage chutes, mail drops, and elevator shafts) adjacent to the units. Demonstrate a maximum leakage of 0.50 cubic feet per minute per square foot (2.54 liters per second per square meter) at 50 Pa of enclosure (i.e., all surfaces enclosing the apartment, including exterior and party walls, floors, and ceilings) or establish a baseline for a future 30% improvement. SCHOOLS Prohibit smoking on site. Signage must be posted at the property line indicating the no smoking policy. PERFORMANCE EBOM, RETAIL, DATA CENTERS, HOSPITALITY, WAREHOUSES & DISTRIBUTION CENTERS None. Residential only 12

13 Demonstrate on a regular basis (at least once every five years) a maximum leakage of 0.50 cubic feet per minute per square foot (2.54 liters per second per square meter) at 50 Pa of enclosure (i.e., all surfaces enclosing the apartment, including exterior and party walls, floors, and ceilings). Projects that do not meet the leakage requirement may demonstrate a 30% improvement over the most recent baseline. The current measurement establishes the new baseline. 13

14 EQ PREREQUISITE: MINIMUM ACOUSTIC PERFORMANCE Required BD&C This prerequisite applies to Schools Intent To provide classrooms that facilitate teacher-to-student and student-to-student communication through effective acoustic design. Requirements SCHOOLS Background Noise Achieve a maximum background noise level of 40 dba from heating, ventilating, and air-conditioning (HVAC) systems in classrooms and other core learning spaces. Follow the recommended methodologies and best practices for mechanical system noise control in ANSI Standard S , Part 1, Annex B; the 2011 HVAC Applications ASHRAE Handbook, Chapter 48, Sound and Vibration Control (with errata but without addenda); AHRI Standard ; or a local equivalent. Exterior Noise Implement measures to minimize noise intrusion from exterior sources and control sound transmission between classrooms and other core learning spaces. For high-noise sites (peak-hour Leq above 60 dba during school hours), include acoustic treatment for exterior noise control. Projects at least one-half mile (800 meters) from any significant noise source (e.g., aircraft overflights, highways, trains, industry) are exempt from the exterior noise control requirement. Reverberation Time Adhere to the following reverberation time requirements. Classrooms and Core Learning Spaces < 20,000 Cubic Feet (570 Cubic Meters) Design classrooms and other core learning spaces to include sufficient sound-absorptive finishes for compliance with the reverberation time requirements specified in ANSI Standard S , Part 1, Acoustical Performance Criteria, Design Requirements and Guidelines for Schools, or a local equivalent for projects outside the United States. Option 1 Finish 100% of all ceiling areas (excluding lights, diffusers, and grilles) in all classrooms and core learning spaces with a material that has a noise reduction coefficient (NRC) of 0.70 or higher. OR Option 2 Confirm that the total area of acoustic wall panels, ceiling finishes, and other sound-absorbent finishes equals or exceeds the total ceiling area of the room (excluding lights, diffusers, and grilles). Materials must have an NRC of 0.70 or higher to be included in the calculation. OR Option 3 Confirm through calculations described in ANSI Standard S that rooms are designed to meet reverberation time requirements as specified in that standard. Classrooms and Core Learning Spaces 20,000 Cubic Feet (570 Cubic Meters) 14

15 Meet the recommended reverberation times for classrooms and core learning spaces described in the NRC-CNRC Construction Technology Update No. 51, Acoustical Design of Rooms for Speech (2002), or a local equivalent. Exceptions Exceptions to the requirements because of a limited scope of work or to observe historic preservation requirements will be considered. 15

16 EQ PREREQUISITE: GREEN CLEANING POLICY Required EB:O&M This prerequisite applies to Existing Buildings: Operations & Maintenance EB:O&M Schools EB:O&M Retail EB:O&M Data Centers EB:O&M Hospitality EB:O&M Warehouses & Distribution Centers Intent To reduce levels of chemical, biological, and particulate contaminants that can compromise air quality, human health, building finishes, building systems, and the environment. Requirements EBOM, SCHOOLS, RETAIL, DATA CENTERS, HOSPITALITY, WAREHOUSES & DISTRIBUTION CENTERS Option 1. In-House Green Cleaning Policy ESTABLISHMENT Have in place a green cleaning policy for the building and site addressing the green cleaning credits, goals and strategies, and personnel listed below. At a minimum, the policy must cover green cleaning procedures, materials, and services that are within the building and site management s control, and include the organization responsible for cleaning the building and building site. Address the requirements of the following credits: EQ Credit: Green Cleaning Purchase of Cleaning Products and Materials EQ Credit: Green Cleaning Cleaning Equipment Goals and Strategies Establish standard operating procedures addressing how an effective cleaning and hard floor and carpet maintenance system will be consistently used, managed, and audited. Address protection of vulnerable building occupants during cleaning. Address selection and appropriate use of disinfectants and sanitizers. Develop guidelines addressing the safe handling and storage of cleaning chemicals used in the building, including a plan for managing hazardous spills and mishandling incidents. Develop goals and strategies for reducing the toxicity of the chemicals used for laundry, ware washing, and other cleaning activities. Develop goals and strategies for promoting the conservation of energy, water, and chemicals used for cleaning. Develop strategies for promoting and improving hand hygiene. Personnel Develop requirements for maintenance personnel. Specifically address contingency planning to manage staffing shortages under a variety of conditions to ensure that basic cleaning services are met and critical cleaning needs are addressed. Include a process to obtain occupant and custodial staff input and feedback after contingency plans are implemented. Determine the timing and frequency of training for maintenance personnel in the hazards of use, disposal, and recycling of cleaning chemicals, dispensing equipment, and packaging. The policy must describe the physical and programmatic scope, duration of applicability, responsible parties (by name or title), sustainability goals and objectives, procedures and strategies for 16

17 implementation, specific metrics by which performance will be measured, and a quality assurance process to evaluate and verify successful implementation. PERFORMANCE Implement a high-performance cleaning program based on the above policy and track performance goals associated with this policy. Option 2. Certified Cleaning Service ESTABLISHMENT None. PERFORMANCE Clean the building with a cleaning service provider, either in-house custodial staff or a contracted service contractor, certified under one of the following: Green Seal s Environmental Standard for Commercial Cleaning Services (GS-42); or International Sanitary Supply Association (ISSA) Cleaning Industry Management Standard for Green Buildings (CIMS-GB). Confirm that the building was audited by the third party within 12 months of the end of the performance period. In addition, the cleaning contractor must develop goals and strategies for promoting the conservation of energy, water, and chemicals used for cleaning the building. 17

18 EQ CREDIT: INDOOR AIR QUALITY MANAGEMENT PROGRAM EB:O&M 2 points This credit applies to Existing Buildings: Operations & Maintenance (2 points) EB:O&M Schools (2 points) EB:O&M Retail (2 points) EB:O&M Data Centers (2 points) EB:O&M Hospitality (2 points) EB:O&M Warehouses & Distribution Centers (2 points) Intent To maintain the well-being of occupants by preventing and correcting indoor air quality problems. Requirements EBOM, SCHOOLS, RETAIL, DATA CENTERS, HOSPITALITY, WAREHOUSES & DISTRIBUTION CENTERS ESTABLISHMENT Develop and implement an indoor air quality (IAQ) management program based on the EPA Indoor Air Quality Building Education and Assessment Model (I-BEAM).Include the IAQ management program in the project s current facilities requirements and Operations and Maintenance Plan.. PERFORMANCE Conduct an I-BEAM audit on a regular basis (at least once every five years) and revise the IAQ management program as appropriate. 18

19 EQ CREDIT: ENHANCED INDOOR AIR QUALITY STRATEGIES BD&C 1 2 points This credit applies to New Construction (1 2 points) Core & Shell (1 2 points) Schools (1 2 points) Retail (1 2 points) Data Centers (1 2 points) Warehouses & Distribution Centers (1 2 points) Hospitality (1 2 points) Healthcare (1 2 points) ID&C 1 2 points This credit applies to Commercial Interiors (1 2 points) Retail (1 3 points) Hospitality (1 2 points) EB:O&M 1 2 points This credit applies to Existing Buildings: Operations & Maintenance (1 2 points) EB:O&M Schools (1 2 points) EB:O&M Retail (1 2 points) EB:O&M Data Centers (1 2 points) EB:O&M Hospitality (1 2 points) EB:O&M Warehouses & Distribution Centers (1 2 points) Intent To promote occupants comfort, well-being, and productivity by improving indoor air quality. Requirements NC, CS, SCHOOLS, RETAIL, DATA CENTERS, WAREHOUSES & DISTRIBUTION CENTERS, HOSPITALITY, HEALTHCARE, CI, RETAIL, HOSPITALITY Option 1. Enhanced IAQ Strategies (1 point) Comply with the following requirements, as applicable. Mechanically ventilated spaces: A. entryway systems; B. interior cross-contamination prevention; and C. filtration. Naturally ventilated spaces: A. entryway systems; and D. natural ventilation design calculations. Mixed-mode systems: 19

20 A. entryway systems; B. interior cross-contamination prevention; C. filtration; D. natural ventilation design calculations; and E. mixed-mode design calculations. A. Entryway Systems Install permanent entryway systems at least 10 feet (3 meters) long in the primary direction of travel to capture dirt and particulates entering the building at high-volume exterior entrances. Acceptable entryway systems include permanently installed grates, grilles, slotted systems that allow for cleaning underneath, rollout mats, and any other materials manufactured as entryway systems with equivalent or better performance. Maintain all on a weekly basis. Warehouses & Distribution Centers only Entryway systems are not required at doors leading from the exterior to the loading dock or garage but must be installed between these spaces and adjacent office areas. Healthcare only In addition to the entryway system, provide pressurized entryway vestibules at high-volume building entrances. B. Interior Cross-Contamination Prevention Sufficiently exhaust each space where hazardous gases or chemicals may be present or used (e.g., garages, housekeeping and laundry areas, copying and printing rooms), using the exhaust rates determined in EQ Prerequisite Minimum Indoor Air Quality Performance or a minimum of 0.50 cfm per square foot, to create negative pressure with respect to adjacent spaces when the doors to the room are closed. For each of these spaces, provide self-closing doors and deck-to-deck partitions or a hard-lid ceiling. C. Filtration Each ventilation system that supplies outdoor air to occupied spaces must have particle filters or aircleaning devices that meet one of the following filtration media requirements: minimum efficiency reporting value (MERV) of 13 or higher, in accordance with ASHRAE Standard ; or Class F7 or higher as defined by CEN Standard EN , Particulate Air Filters for General Ventilation, Determination of the Filtration Performance. Replace all air filtration media after completion of construction and before occupancy. Data Centers only The above filtration media requirements are required only for ventilation systems serving regularly occupied spaces. D. Natural Ventilation Design Calculations Demonstrate that the system design for occupied spaces employs the appropriate strategies in Chartered Institution of Building Services Engineers (CIBSE) Applications Manual AM10, March 2005, Natural Ventilation in Non-Domestic Buildings, Section 2.4. E. Mixed-Mode Design Calculations Demonstrate that the system design for occupied spaces complies with CIBSE Applications Manual , Mixed Mode Ventilation. Option 2. Additional Enhanced IAQ Strategies (1 point BD&C and ID&C, 2 points Retail CI) Comply with the following requirements, as applicable. Mechanically ventilated spaces (select one): A. exterior contamination prevention; 20

21 B. increased ventilation; C. carbon dioxide monitoring; or D. additional source control and monitoring. Naturally ventilated spaces: A. exterior contamination prevention; D. additional source control and monitoring; and E. natural ventilation room by room calculations. Mixed-mode systems: A. exterior contamination prevention; B. increased ventilation; D. additional source control and monitoring; and E. natural ventilation room-by-room calculations. A. Exterior Contamination Prevention Design the project to minimize and control the entry of pollutants into the building. Ensure through the results of computational fluid dynamics modeling, Gaussian dispersion analyses, wind tunnel modeling, or tracer gas modeling that outdoor air contaminant concentrations at outdoor air intakes are below the thresholds listed in Table 1 (projects outside the United States must follow the EPA guideline or local equivalent, whichever is more stringent). Table 1. Maximum concentrations of pollutants at outdoor air intakes Pollutants Maximum concentration Standard Those regulated by National Ambient Air Quality Standards (NAAQS) Allowable annual average OR 8-hour or 24-hour average where an annual standard does not exist OR Rolling 3-month average National Ambient Air Quality Standards (NAAQS) B. Increased Ventilation Increase breathing zone outdoor air ventilation rates to all occupied spaces by at least 30% above the minimum rates as determined in EQ Prerequisite Minimum Indoor Air Quality Performance. C. Carbon Dioxide Monitoring Monitor CO 2 concentrations within all densely occupied spaces. CO 2 monitors must be between 3 and 6 feet (90 and 180 centimeters) above the floor. CO 2 monitors must have an audible or visual indicator or alert the building automation system if the sensed CO 2 concentration exceeds the setpoint by more than 10%. Calculate appropriate CO 2 setpoints using methods in ASHRAE , Appendix C. D. Additional Source Control and Monitoring For spaces where air contaminants are likely, evaluate potential sources of additional air contaminants besides CO 2. Develop and implement a materials-handling plan to reduce the likelihood of contaminant release. Install monitoring systems with sensors designed to detect the specific contaminants. An alarm must indicate any unusual or unsafe conditions. E. Natural Ventilation Room-by-Room Calculations Follow CIBSE AM10, Section 4, Design Calculations, to predict that room-by-room airflows will provide effective natural ventilation. 21

22 EBOM, SCHOOLS, RETAIL, DATA CENTERS, HOSPITALITY, WAREHOUSES & DISTRIBUTION CENTERS Option 1. Entryway Systems (1 point) ESTABLISHMENT Have in place permanent entryway systems at least 10 feet (3 meters) long in the primary direction of travel to capture dirt and particulates entering the building at regularly used exterior entrances. Acceptable entryway systems include permanently installed grates, grilles, slotted systems that allow for cleaning underneath, rollout mats, and any other materials manufactured as entryway systems with equal to or better performance. Maintain all on a weekly basis. Warehouses & Distribution Centers only Buildings are not required to provide entryway systems at doors leading from the exterior to the loading dock/garage, but must provide them between these spaces and adjacent office areas. PERFORMANCE Confirm that entryway systems are in place and have been maintained on a weekly basis. Option 2. Additional Enhanced IAQ Strategies (1 point) Comply with therequirements of at least one of the following. Filtration for Mechanically Ventilated Spaces ESTABLISHMENT Each ventilation system that supplies outdoor air to occupied spaces must have particle filters or air cleaning devices. These filters or devices must meet one of the following filtration media requirements: minimum efficiency reporting value (MERV) of 13 or higher, in accordance with ASHRAE Standard ; Class F7 or higher as defined by CEN Standard EN , Particulate Air Filters for General Ventilation, Determination of the Filtration Performance; or Data Centers only The above filtration media requirements are required only for ventilation systems serving regularly occupied spaces. PERFORMANCE Establish and follow a regular schedule for maintenance and replacement of filtration media according to the manufacturer s recommended interval. Carbon Dioxide Monitors ESTABLISHMENT Have in place CO 2 monitors in all densely occupied spaces. Rooms smaller than 150 square feet (14 square meters) are exempt. CO 2 monitors must be between 3 and 6 feet (90 and 180 centimeters) above the floor. Configure the system to generate a visual alarm to the system operator if the differential CO 2 concentration in any zone rises more than 15% above that corresponding to the minimum outdoor air rate required in the ventilation section of EA Prerequisite Minimum Indoor Air Quality Performance. PERFORMANCE Test and calibrate CO 2 sensors to have an accuracy of no less than 75 parts per million or 5% of the reading, whichever is greater. Sensors must be tested and calibrated at least once every five years or per the manufacturer s recommendation, whichever is shorter. 22

23 Monitor CO 2 sensors with a system configured to trend CO 2 concentrations in intervals no greater than 30 minutes. Outdoor Air Monitoring for Mechanically Ventilated Spaces ESTABLISHMENT For variable air volume systems, provide a direct outdoor airflow measurement device capable of measuring the minimum outdoor air intake flow. This device must measure the minimum outdoor air intake flow with an accuracy of +/ 10% of the design minimum outdoor airflow rate required in the ventilation section of EQ Prerequisite Minimum Indoor Air Quality Performance. An alarm must indicate when the outdoor airflow value varies by 15% or more from the outdoor airflow setpoint. For constant-volume systems, balance outdoor airflow to the design minimum outdoor airflow rate required in the ventilation section of EQ Prerequisite Minimum Indoor Air Quality Performance, or higher. Install a current transducer on the supply fan, an airflow switch, or similar monitoring device. PERFORMANCE Calibrate all measurement devices within the manufacturer s recommended interval. Outdoor Air Monitoring for Naturally Ventilated Spaces ESTABLISHMENT Provide a direct exhaust airflow measurement device capable of measuring the exhaust airflow. This device must measure the exhaust airflow with an accuracy of +/ 10% of the design minimum exhaust airflow rate. An alarm must indicate when airflow values vary by 15% or more from the exhaust airflow setpoint. PERFORMANCE Calibrate all measurement devices within the manufacturer s recommended interval. Alarmed Openings for Naturally Ventilated Spaces ESTABLISHMENT Provide automatic indication devices on all openings intended to meet the minimum opening requirements. An alarm must indicate when any one of the openings is closed during occupied hours. PERFORMANCE Maintain and confirm proper operation of the automatic indication devices. 23

24 EQ CREDIT: LOW-EMITTING INTERIORS BD&C 1 3 points This credit applies to New Construction (1 3 points) Core & Shell (1 3 points) Schools (1 3 points) Retail (1 3 points) Data Centers (1 3 points) Warehouses & Distribution Centers (1 3 points) Hospitality (1 3 points) Healthcare (1 3 points) ID&C 1 3 points This credit applies to Commercial Interiors (1 3 points) Retail (1 3 points) Hospitality (1 3 points) Intent To reduce concentrations of chemical contaminants that can damage air quality, human health, productivity, and the environment. Requirements NC, CS, SCHOOLS, RETAIL, DATA CENTERS, WAREHOUSES & DISTRIBUTION CENTERS, HOSPITALITY, HEALTHCARE, CI, RETAIL, HOSPITALITY This credit includes requirements for product manufacturing as well as project teams. It covers volatile organic compound (VOC) emissions into indoor air and the VOC content of materials, as well as the testing methods by which indoor VOC emissions are determined. Different materials must meet different requirements to be considered compliant for this credit. The building interior and exterior are organized in seven categories, each with different thresholds of compliance. The building interior is defined as everything within the waterproofing membrane. The building exterior is defined as everything outside and inclusive of the primary and secondary weatherproofing system, such as waterproofing membranes and air- and water-resistive barrier materials. Option 1. Product Category Calculations Achieve the threshold level of compliance with emissions and content standards for the number of product categories listed in Table 2. Table 1. Thresholds of compliance with emissions and content standards for 7 categories of materials Emissions and content Category Threshold requirements Interior paints and coatings applied on site At least 90%, by volume, for emissions; 100% for VOC content General Emissions Evaluation for paints and coatings applied to walls, floors, and ceilings VOC content requirements for wet applied products Interior adhesives and sealants At least 90%, by volume, for General Emissions Evaluation 24

25 applied on site (including emissions; 100% for VOC VOC content requirements for flooring adhesive) content wet applied products Flooring 100% General Emissions Evaluation Composite wood Ceilings, walls, thermal, and acoustic insulation Furniture (include in calculations if part of scope of work) Healthcare and Schools Projects only: Exterior applied products 100% not covered by other Composite Wood Evaluation categories 100% General Emissions Evaluation Healthcare, Schools only Additional insulation requirements At least 90%, by cost Furniture Evaluation At least 90%, by volume Exterior Applied Products Table 2. Points for number of compliant categories of products Compliant categories Points NC, CS, NC Retail, DC, WDC, NC Hos projects without furniture NC, CS, NC Retail, DC, WDC, NC Hos projects with furniture, CI, CI Retail, CI Hos Schools, HC without furniture Schools, HC with furniture Option 2. Budget Calculation Method If some products in a category do not meet the criteria, project teams may use the budget calculation method (Table 3). Table 3. Points for percentage compliance, under budget calculation method Percentage of total Points 50% and < 70% 1 70% and < 90% 2 90% 3 The budget method organizes the building interior into six assemblies: flooring; ceilings; walls; thermal and acoustic insulation; 25

LEED v4 Building Design and Construction Quiz #8 EQ

LEED v4 Building Design and Construction Quiz #8 EQ LEED v4 Building Design and Construction Quiz #8 EQ 1. Which of these is considered an unoccupied space? [Choose three] A. School classroom B. Mechanical room C. Meeting room D. Locker room E. Restroom

More information

Fill-In, Multiple Choice, Matching

Fill-In, Multiple Choice, Matching LEED Green Associate Activity #8 Indoor Environmental Quality (EQ) Before completing this Activity Read: GA02 - Pgs. 507-508 & 599-602 & GA09 Pgs. 107-139 (see lorisweb.com) Note the following abbreviations

More information

Chapter 8: Indoor Environmental Quality

Chapter 8: Indoor Environmental Quality Chapter 8: Indoor Environmental Quality 1 Learning Objectives Minimum indoor air quality performance Environmental tobacco smoke control Enhanced indoor air quality strategies Low-emitting materials Construction

More information

LEED And Your Indoor Environment

LEED And Your Indoor Environment LEED And Your Indoor Environment An overview of LEED v3 and Indoor Air Quality David McCauley, CIE Council Certified Indoor Environmentalist ACAC CIE #1008005 USGBC's Mission To transform the way buildings

More information

INDDOR ENVIRONMENTAL QUALITY

INDDOR ENVIRONMENTAL QUALITY INDDOR ENVIRONMENTAL QUALITY IEQ- P1: MINIMUM INDOOR AIR QUALITY PERFORMANCE To establish minimum indoor air quality (IAQ) performance to enhance indoor air quality in buildings, thus contributing to the

More information

How We Obtained LEED Certification pertaining to the Indoor Environmental Quality Category. Ron Fields, CAFS, NCT General Dynamics C4 Systems

How We Obtained LEED Certification pertaining to the Indoor Environmental Quality Category. Ron Fields, CAFS, NCT General Dynamics C4 Systems How We Obtained LEED Certification pertaining to the Indoor Environmental Quality Category Ron Fields, CAFS, NCT General Dynamics C4 Systems Outline What is LEED EB? GD LEED Costs and savings IEQ Prerequisites

More information

LEED Best Practices Save $$$

LEED Best Practices Save $$$ 16 Savings result where LEED has been applied to improve IAQ! LEED Best Practices Save $$$ A growing body of green building case studies document the benefits of healthy IAQ in the workplace Learn More

More information

Increased ventilation

Increased ventilation Increased ventilation EQ1.3 Possible point Intent To provide additional outdoor air ventilation to improve indoor air quality (IAQ) for improved occupant comfort, To provide additional outdoor air ventilation

More information

Indoor Air Quality (IAQ) Requirements

Indoor Air Quality (IAQ) Requirements University of New Hampshire University of New Hampshire Scholars' Repository Division 01 General Requirements Chapter 5 Technical Construction and Renovation Standards 1-25-2013 013560 - Indoor Air Quality

More information

Note year for Reference as Specified in the LEED V Manual.

Note year for Reference as Specified in the LEED V Manual. PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Sustainable design Project goals. 2. Sustainable design product requirements. B. Related Sections: 1. Section 01810 - Commissioning: General commissioning

More information

Allowance Table for: General:

Allowance Table for: General: Allowance Table for: Adopting Credits from LEED Canada for New Construction and Major Renovations (NC) 2009 and LEED Canada for Core and Shell Development (CS) 2009 for LEED Canada-NC v1.0 (with or without

More information

Indoor Environmental Quality Policy

Indoor Environmental Quality Policy University of Florida Indoor Environmental Quality Policy For New Construction and Renovation Environmental Health and Safety Division June 2009 Introduction Effective management of the indoor environmental

More information

LEED LEED. Leadership in Energy and Environmental Design. A voluntary, consensus-based. high-performance, sustainable buildings and neighborhoods

LEED LEED. Leadership in Energy and Environmental Design. A voluntary, consensus-based. high-performance, sustainable buildings and neighborhoods LEED An Introduction to LEED V3 2009 LEED Leadership in Energy and Environmental Design A voluntary, consensus-based national standard for developing high-performance, sustainable buildings and neighborhoods

More information

SECTION INDOOR AIR QUALITY MANAGEMENT PLAN. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION INDOOR AIR QUALITY MANAGEMENT PLAN. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. SECTION 018119 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting

More information

Understanding the 2010 California Green Building Standards Code

Understanding the 2010 California Green Building Standards Code Understanding the 2010 California Green Building Standards Code ICC High Desert Chapter September 23, 2010 Presented by Bill Read Today s agenda CalGreen Code- some background Overview of Code Chapter

More information

Contractor's Letter of Assurance

Contractor's Letter of Assurance Contractor's Letter of Assurance Instructions WELL Certification is determined by onsite Performance Verification and documentation, including Letters of Assurance from the appropriate professionals overseeing

More information

Where Green Turns into Gold Improving Indoor Environmental Quality with LEED

Where Green Turns into Gold Improving Indoor Environmental Quality with LEED Eastern Illinois Safety Network January 2011 Where Green Turns into Gold Improving Indoor Environmental Quality with LEED Jean Ascoli, LEED AP BD+C Architect, Energy Specialist Building Research Council,

More information

Prerequisite. prerequisite.

Prerequisite. prerequisite. LEED v4 for Building Operations and Maintenance Summary of changes from LEED 2009 LOCATION AND TRANSPORTATION SUSTAINABLE SITES Alternative Transportation Site Management Policy LEED Certified Design and

More information

LEED for Homes Approved ID Request:

LEED for Homes Approved ID Request: LEED for Homes Approved ID Request: Introduction The following is an Innovative Design Request (IDR) that has been approved for broader use in for the LEED for Homes program. This credit should not be

More information

Construction Indoor Air Quality (IAQ) Management Plan

Construction Indoor Air Quality (IAQ) Management Plan Denver School of Science & Technology Middle School 2000 Valentia Street Denver, CO 80238 Telephone: 303-643-5775 Main Fax: 303-673-5776 Construction Indoor Air Quality (IAQ) Management Plan Denver School

More information

Component Goal Performance Measurement Unit. meet the sustainability criteria. described below. described below. from landfills.

Component Goal Performance Measurement Unit. meet the sustainability criteria. described below. described below. from landfills. Facility Maintenance and Renovation Policy for Merchandise Mart Effective date: May 1, 2018 i. Scope This policy applies to any ongoing facility maintenance activities and any facility renovations that

More information

CALGREEN NON-RESIDENTIAL BUILDING Checklist

CALGREEN NON-RESIDENTIAL BUILDING Checklist CALGREEN NON-RESIDENTIAL BUILDING Checklist REVISED 11/18/14 New non-residential buildings shall be designed to include the green building mandatory measures specified in this checklist. This checklist

More information

Non-Residential CALGreen (CGBSC) Correction List (To be inserted within the body of the Non-Residential/Plan Check Correction List)

Non-Residential CALGreen (CGBSC) Correction List (To be inserted within the body of the Non-Residential/Plan Check Correction List) Non-Residential CALGreen (CGBSC) Correction List (To be inserted within the body of the Non-Residential/Plan Check Correction List) 1. Because of special conditions, the City is requiring the construction

More information

Indoor Air Quality and Mechanical Ventilation (Page 1 of 5)

Indoor Air Quality and Mechanical Ventilation (Page 1 of 5) Indoor Air Quality and Mechanical Ventilation (Page 1 of 5) Title 24, Part 6, Section 150.0(o) Ventilation for Indoor Air Quality. All dwelling units shall meet the requirements of ANSI/ASHRAE Standard62.2.

More information

A. The project is intended to achieve LEED Certification at the Silver Level per the U.S. Green Building Council LEED for Schools 2007 rating system.

A. The project is intended to achieve LEED Certification at the Silver Level per the U.S. Green Building Council LEED for Schools 2007 rating system. SECTION 23 01 01 HVAC LEED REQUIREMENTS PART 1 -GENERAL 1.1 WORK INCLUDES A. Compliance with LEED project requirements. B. Coordination of LEED construction phase activities. C. Data gathering of construction

More information

Understanding LEED for Homes v4

Understanding LEED for Homes v4 Understanding LEED for Homes v4 A Nine Part Series Module #7: Environmental Quality (EQ) 1 CE for this course 9 CEs for entire session AIA (HSW) LEED Specific Continuing Education Local & State Contractor

More information

Contractor's Letter of Assurance

Contractor's Letter of Assurance Contractor's Letter of Assurance Instructions WELL Certification and WELL Core and Shell Compliance are determined by onsite Performance Verification and Documentation, including Letters of Assurance from

More information

City of Millbrae 2016 CALIFORNIA GREEN BUILDING CODE CHECKLIST FOR NEW NONRESIDENTIAL BUILDINGS

City of Millbrae 2016 CALIFORNIA GREEN BUILDING CODE CHECKLIST FOR NEW NONRESIDENTIAL BUILDINGS City of Millbrae 2016 CALIFORNIA GREEN BUILDING CODE CHECKLIST FOR NEW NONRESIDENTIAL BUILDINGS Building Permit Number: Site Address: In the column labeled Specify where each Measure can be found on the

More information

LEED EB:OM Credit Catagories

LEED EB:OM Credit Catagories LEED EB:OM Credit Catagories Engr Theresa Palma-Austria, LEED AP O+M Arch Laurice Orillano-Ayab, LEED GA LEED for Existing Buildings : Operations & Maintenance Barone International LEED EB:OM Categories

More information

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION Permit (Case) number: GREEN CODE (NON-RESIDENTIAL OCCUPANCIES) CERTIFICATE OF COMPLIANCE AND CHECKLIST A

More information

L E E D S C O R E C A R D ( B U I L D I N G D E S I G N & C O N S T R U C T I O N )

L E E D S C O R E C A R D ( B U I L D I N G D E S I G N & C O N S T R U C T I O N ) Project Zip Code: 92101 Project Anticipated Rating: LEED-NC Gold L E E D 2 0 0 9 S C O R E C A R D ( B U I L D I N G D E S I G N & C O N S T R U C T I O N ) 62 22 26 Project Totals A-Achieved X-Documented

More information

CITY OF PALM DESERT (COPY THIS FORM ONTO THE BUILDING PLANS)

CITY OF PALM DESERT (COPY THIS FORM ONTO THE BUILDING PLANS) CITY OF PALM DESERT 2013 NON-RESIDENTIAL MANDATORY MEASURES CHECKLIST For Additions of 1000 sq. ft. or more and alterations with a valuation of $200,000 or more. (COPY THIS FORM ONTO THE BUILDING PLANS)

More information

TEXAS FACILITIES COMMISSION Edit Date: 4/13/2012 ARCHITECTURAL/ENGINEERING GUIDELINES

TEXAS FACILITIES COMMISSION Edit Date: 4/13/2012 ARCHITECTURAL/ENGINEERING GUIDELINES General The following guidelines must be met by both the Architect/Engineer (A/E) consultant and the contractor to assure indoor air quality of the building being provided. At the direction of the Project

More information

500 WEST PUTNAM AVENUE GREENWICH, CT

500 WEST PUTNAM AVENUE GREENWICH, CT LEED-CI ANALYSIS June 2015 500 WEST PUTNAM AVENUE GREENWICH, CT To learn more please visit the sustainability section of our website: www.slgreen.com or contact Jay Black, SL Green s director of sustainability

More information

The 2010 California Green Building Code; "CalGreen" effective January 1st, 2011

The 2010 California Green Building Code; CalGreen effective January 1st, 2011 1 The 2010 California Green Building Code; "CalGreen" effective January 1st, 2011 Existing Culver City Building Safety Division Green Programs: The Culver City Mandatory Photovoltaic Requirement, effective

More information

MANDATORY GREEN CODE STANDARDS NEW NONRESIDENTIAL CHECKLIST & CERTIFICATION

MANDATORY GREEN CODE STANDARDS NEW NONRESIDENTIAL CHECKLIST & CERTIFICATION HANDOUT 210 JULY 2012 PURPOSE: CITY OF CORONADO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION 1825 STRAND WAY, CORONADO, CA 92118 (619) 522-7331 / (619) 522-2418 (FAX) COMMDEV@CORONADO.CA.US MANDATORY

More information

ALBUQUERQUE PUBLIC SCHOOLS Facility Design & Construction / Maintenance & Operations

ALBUQUERQUE PUBLIC SCHOOLS Facility Design & Construction / Maintenance & Operations ALBUQUERQUE PUBLIC SCHOOLS Facility Design & Construction / Maintenance & Operations LEEDv4 Guideline February 1, 2017 Tony Sparks David Ritchey Stuart Ingham Karen Alarid Kris Callori Noreen Richards

More information

SECTION SUSTAINABILITY CERTIFICATION REQUIREMENTS LEED NC V3

SECTION SUSTAINABILITY CERTIFICATION REQUIREMENTS LEED NC V3 PART 1 - GENERAL 1.1 DESCRIPTION SECTION 01 81 13.01 SUSTAINABILITY CERTIFICATION REQUIREMENTS LEED NC V3 A. This section describes requirements and procedures which are additive to and compatible with

More information

HPBS [ HIGH PERFORMANCE BUILDING STANDARD]

HPBS [ HIGH PERFORMANCE BUILDING STANDARD] HPBS [ HIGH PERFORMANCE BUILDING STANDARD] STATE OF MONTANA HIGH PERFORMANCE BUILDING STANDARDS MINIMUM REQUIREMENTS FOR ALL PROJECTS UNDER 17-7-201, MCA PART 2 1.1 DESIGN AND DOCUMENTATION A. Incorporate

More information

Colorado Mountain College: Sustainable Design Standards

Colorado Mountain College: Sustainable Design Standards Colorado Mountain College: Sustainable Design Standards Objective: Design and build to the highest energy and water standards in order to meet the College s Carbon Neutrality Objective in the most cost-effective

More information

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma LEED Green Building Certification The purpose of the LEED Green Building Rating is to provide a national standard that aims to improve environmental, health and economic performance of buildings using

More information

What s New in LEED v4

What s New in LEED v4 July 2017 AIA Course Number: LEED17A What s New in LEED v4 A focus on Material & Resources (MR) and Indoor Environmental Quality (IEQ) AIA Registration 2 Armstrong World Industries is a registered provider

More information

30% 85% 37% PROJECT HIGHLIGHTS LEED Facts. Lecture Hall BioLabs Building

30% 85% 37% PROJECT HIGHLIGHTS LEED Facts. Lecture Hall BioLabs Building LECTURE HALL BIOLOGICAL LABORATORIES BUILDING 16 Divinity Avenue, Cambridge, MA 02138 LEED-CI V3 GOLD The Biological Laboratories (BioLabs) Building Lecture Hall, located on the first floor of 16 Divinity

More information

Indoor Environmental Quality

Indoor Environmental Quality Indoor Environmental Quality Factors that affect IEQ Air Quality IEQ Materials Connectivity 1 Fresh Air Ventilation Enhance indoor air quality Comfort Performance Well-being of the occupants Good IEQ can

More information

IAQ - BEYOND MATERIAL SELECTION

IAQ - BEYOND MATERIAL SELECTION IAQ - BEYOND MATERIAL SELECTION Sean McCrady, CMC, CIEC, LEED AP Vice President & Regional Manager Healthy Buildings, Western Region WASHINGTON, DC NEW YORK LOS ANGELES LEARNING OBJECTIVES Installation

More information

LEED-CI ANALYSIS 115 STEVENS AVENUE VALHALLA, NY

LEED-CI ANALYSIS 115 STEVENS AVENUE VALHALLA, NY LEED-CI ANALYSIS June 2015 115 STEVENS AVENUE VALHALLA, NY To learn more please visit the sustainability section of our website: www.slgreen.com or contact Jay Black, SL Green s director of sustainability

More information

VICOSTONE QUARTZ SURFACES & LEED CERTIFICATION

VICOSTONE QUARTZ SURFACES & LEED CERTIFICATION VICOSTONE QUARTZ SURFACES & LEED CERTIFICATION CONTENTS I. BACKGROUND II. VICOSTONE QUARTZ SURFACES & LEED POINTS III. VICOSTONE ENVIRONMENTAL COMMITMENT I. BACKGROUND ABOUT VICOSTONE JOINT STOCK COMPANY

More information

A Building Commissioning Overview. Presented by: Goetting & Associates Commissioning

A Building Commissioning Overview. Presented by: Goetting & Associates Commissioning A Building Commissioning Overview Presented by: Goetting & Associates Commissioning www.goettingcx.com What is the Definition of Commissioning? Building Commissioning is a Quality Assurance Process of

More information

New Montgomery County Elementary School. Construction Indoor Air Quality Management Plan IEQc3.1 IAQ Plan During Construction

New Montgomery County Elementary School. Construction Indoor Air Quality Management Plan IEQc3.1 IAQ Plan During Construction New Montgomery County Elementary School Construction Indoor Air Quality Management Plan IEQc3.1 IAQ Plan During Construction LEED certification promotes environmentally friendly buildings and sites through

More information

ATTACHMENT N LEED PROJECT PROCEDURES

ATTACHMENT N LEED PROJECT PROCEDURES ATTACHMENT N LEED PROJECT PROCEDURES 1. All subcontractors, sub-subcontractors and suppliers at all tiers are to include the following items in their trade scope of work: a. Submit data and documentation

More information

LEED 2009 FOR EXISTING BUILDINGS OPERATIONS AND MAINTENANCE ACP DOCUMENTATION GUIDANCE FOR PROJECTS OUTSIDE THE U.S.

LEED 2009 FOR EXISTING BUILDINGS OPERATIONS AND MAINTENANCE ACP DOCUMENTATION GUIDANCE FOR PROJECTS OUTSIDE THE U.S. LEED 2009 FOR EXISTING BUILDINGS OPERATIONS AND MAINTENANCE ACP DOCUMENTATION GUIDANCE FOR PROJECTS OUTSIDE THE U.S. October 2011 This is a draft document and can be used only in the interim until LEED

More information

LEED-CI ANALYSIS 6 LANDMARK SQUARE STAMFORD, CT

LEED-CI ANALYSIS 6 LANDMARK SQUARE STAMFORD, CT LEED-CI ANALYSIS June 2015 6 LANDMARK SQUARE STAMFORD, CT To learn more please visit the sustainability section of our website: www.slgreen.com or contact Jay Black, SL Green s director of sustainability

More information

GREEN CLEANING POLICY 7/30/2013

GREEN CLEANING POLICY 7/30/2013 GREEN CLEANING POLICY 7/30/2013 This document meets the requirements for the USGBC LEED 2009 for Existing Buildings: Operations & Maintenance (LEED- EBOM 2009 v.3) Contents Introduction 4 Intent Sustainability

More information

LEED-CI ANALYSIS 4 LANDMARK SQUARE STAMFORD, CT

LEED-CI ANALYSIS 4 LANDMARK SQUARE STAMFORD, CT LEED-CI ANALYSIS June 2015 4 LANDMARK SQUARE STAMFORD, CT To learn more please visit the sustainability section of our website: www.slgreen.com or contact Jay Black, SL Green s director of sustainability

More information

Thermiser Insulated Rolling Doors Comprehensive Guide to Earning LEED v4 Credits

Thermiser Insulated Rolling Doors Comprehensive Guide to Earning LEED v4 Credits Thermiser Insulated Rolling Doors Comprehensive Guide to Earning LEED v4 Credits 1 Thermiser Insulated Rolling Doors Earning LEED v4 Credits Cookson s Thermiser Insulated Rolling Doors can provide a significant

More information

2011 Enterprise Green Communities Criteria Checklist

2011 Enterprise Green Communities Criteria Checklist 2011 Enterprise Green Communities Criteria Checklist This checklist provides an overview of the technical requirements within the Enterprise Green Communities Criteria. To achieve Enterprise Green Communities

More information

ASSA ABLOY Door Security Solutions Contribution Toward LEED v4 Certification

ASSA ABLOY Door Security Solutions Contribution Toward LEED v4 Certification Door Security Solutions Contribution Toward LEED v4 Certification U.S. Green Building Council's Leadership in Energy and Environmental Design, or LEED, is used throughout the world to build healthy and

More information

LEED-CI ANALYSIS 1 LANDMARK SQUARE STAMFORD, CT

LEED-CI ANALYSIS 1 LANDMARK SQUARE STAMFORD, CT LEED-CI ANALYSIS June 2015 1 LANDMARK SQUARE STAMFORD, CT To learn more please visit the sustainability section of our website: www.slgreen.com or contact Jay Black, SL Green s director of sustainability

More information

SECTION SUSTAINABLILITY CERTIFICATION REQUIREMENTS - GREEN GLOBES

SECTION SUSTAINABLILITY CERTIFICATION REQUIREMENTS - GREEN GLOBES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 01 81 13.21 SUSTAINABLILITY CERTIFICATION REQUIREMENTS - GREEN GLOBES A. This section describes general requirements and procedures to comply with the Green Building

More information

Lori A. Brown, LEED AP BD+C, LEED AP ND, LEED AP O+M -- LEED Green Associate Exam -- Power Jam Study! -- lorisweb.com 1

Lori A. Brown, LEED AP BD+C, LEED AP ND, LEED AP O+M -- LEED Green Associate Exam -- Power Jam Study! -- lorisweb.com 1 Lori A. Brown, LEED AP BD+C, LEED AP ND, LEED AP O+M -- LEED Green Associate Exam -- Power Jam Study! -- lorisweb.com 1 Lori A. Brown, LEED AP BD+C, LEED AP ND, LEED AP O+M -- LEED Green Associate Exam

More information

When Building a New Home

When Building a New Home When Building a New Home Building a new home provides the opportunity for preventing indoor air problems. However, it can result in exposure to higher levels of indoor air contaminants if careful attention

More information

LEED Application Guide for Multiple Buildings and On Campus Building Projects

LEED Application Guide for Multiple Buildings and On Campus Building Projects LEED Application Guide for Multiple Buildings and On Campus Building Projects For Use with 2009 LEED Rating Systems for Design and Construction and Operations and Maintenance Released October 31, 2011

More information

Introduction to LEED v4 Lyle Scott May 22, 2014

Introduction to LEED v4 Lyle Scott May 22, 2014 Introduction to LEED v4 Lyle Scott May 22, 2014 Agenda Introduction to LEED v4 Taking a Global Approach New and More Stringent Major & Resources Introduction to LEED v4 Global Approach LEED Online Alternative

More information

Siena Recycled Rubber contributions to LEED NC, CS, Schools, Retail, and LEED for Canada: NC Credit Credit Description How Siena Recycled Rubber Products Contribute * MR 4 Recycled MR 5 Regional Material

More information

MEP's Letter of Assurance

MEP's Letter of Assurance MEP's Letter of Assurance Instructions Multifamily Residential WELL Certification is determined by onsite Performance Verification and documentation, including Letters of Assurance from the appropriate

More information

LEED-CI ANALYSIS 140 GRAND STREET WHITE PLAINS, NY

LEED-CI ANALYSIS 140 GRAND STREET WHITE PLAINS, NY LEED-CI ANALYSIS June 2015 140 GRAND STREET WHITE PLAINS, NY To learn more please visit the sustainability section of our website: www.slgreen.com or contact Jay Black, SL Green s director of sustainability

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 01 8113.53 - SUSTAINABLE DESIGN REQUIREMENTS - GREEN GLOBES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Errata Sheet. LEED for Schools Reference Guide First Edition for the document titled:

Errata Sheet. LEED for Schools Reference Guide First Edition for the document titled: Errata Sheet for the document titled: LEED for Schools Reference Guide First Edition 2007 Notes: Updates to this document are posted on the LEED for Schools Rating System page and the Reference Guide electronic

More information

LEED 2009 for Commercial Interiors. Presented by: Colleen McCafferty LEED AP Roselia Harris LEED AP

LEED 2009 for Commercial Interiors. Presented by: Colleen McCafferty LEED AP Roselia Harris LEED AP LEED 2009 for Commercial Interiors Presented by: Colleen McCafferty LEED AP Roselia Harris LEED AP Homes Commercial Interiors Core & Shell New Construction Schools Healthcare Existing Building Operations

More information

Healthier Home Environments Benefit Everyone

Healthier Home Environments Benefit Everyone Healthier Home Environments Benefit Everyone ALA Health House Mission To improve the way homes are built, renovated and maintained in America to be: Healthier More energy efficient More resource efficient

More information

GREEN BUILDING REQUIREMENTS

GREEN BUILDING REQUIREMENTS City of El Cajon Building and Fire Safety Division GREEN BUILDING REQUIREMENTS 200 Civic Center Way FOR NON-RESIDENTIAL CONSTRUCTION El Cajon, CA 92020 Phone: (619) 441-1726 In order to facilitate sustainable

More information

Regupol Sonus & SonusWave Underlayment Contrubutions to LEED

Regupol Sonus & SonusWave Underlayment Contrubutions to LEED NC, CS, Schools, Retail, and LEED for Canada: NC MR 4 Use materials with recycle content such that the sum of post-consumer content plus one-half of the pre-consumer content constitutes at least 10% or

More information

Indoor Air Quality Management Plan for LEED

Indoor Air Quality Management Plan for LEED Terminal Development Program Contract 1: 201301B San Diego Airport Terminal 2 West Expansion Indoor Air Quality Management Plan for LEED Prepared by HVAC Design Builder: California Comfort Systems USA

More information

2010 CALIFORNIA GREEN BUILDING STANDARDS CODE SUMMARY OF NONRESIDENTIAL MANDATORY MEASURES

2010 CALIFORNIA GREEN BUILDING STANDARDS CODE SUMMARY OF NONRESIDENTIAL MANDATORY MEASURES BUILDING INSPECTION DIVISION ENGINEERING, SURVEYING & PERMIT SERVICES DEPARTMENT CHARLES LACKEY, P.E., DIRECTOR 2700 M STREET, SUITE 570 BAKERSFIELD, CA 93301-2370 Phone: (661) 862-8650 Fax: (661) 862-8678

More information

Alpen Windows - LEED Impact Analysis

Alpen Windows - LEED Impact Analysis ALPEN WINDOWS MATERIALS: Energy Efficient Windows Alpen Windows - LEED Impact Analysis SECTION I. PRODUCT IDENTIFICATION Product Name: Alpen Windows Manufacturer: Alpen High Performance Products 6268 Monarch

More information

LEED v4: the program

LEED v4: the program LEED v4: the program LEED v4: Where are we now? Engagement Completed six public comment periods Received over 22,000 public comments Over 70 projects enrolled in LEED v4 Beta Program Program Tools Development

More information

SECTION SUSTAINABLE DESIGN REQUIREMENTS LEED FOR NEW CONSTRUCTION AND MAJOR RENOVATIONS

SECTION SUSTAINABLE DESIGN REQUIREMENTS LEED FOR NEW CONSTRUCTION AND MAJOR RENOVATIONS SECTION 018113.13 - SUSTAINABLE DESIGN REQUIREMENTS LEED FOR NEW CONSTRUCTION AND MAJOR RENOVATIONS PART 1 - GENERAL 1.1 SUMMARY A. Section includes general requirements and procedures for compliance with

More information

Columbia Skylights may qualify your project for LEED points in the following categories: Columbia Skylights - Potential Contribution to LEED projects

Columbia Skylights may qualify your project for LEED points in the following categories: Columbia Skylights - Potential Contribution to LEED projects 3.0 Statement Columbia Skylights Statement for New Construction (NC) Version 3.0 Credit Documentation The Leadership in Energy and Environmental Design () Green Building Rating System promotes the adoption

More information

Balco, Inc. Stair Nosings

Balco, Inc. Stair Nosings Balco, Inc. Stair Nosings Applicable Rating Systems: CI - Commercial Interiors RETAIL CI - Retail, Commercial Interiors Balco, Inc. Stair Nosings Contributes to LEED Credits Zero maintenance, reducing

More information

LEED v4 Technical Bulletin Building Design + Construction

LEED v4 Technical Bulletin Building Design + Construction LEED v4 Technical Bulletin Building Design + Construction Background This document outlines Carboline s contributions towards available LEED v4 credits. Carboline is committed to developing and manufacturing

More information

How LEED v4 Impacts Energy Professionals and Mirrors Broader Sustainability Trends. Dan LeBlanc Senior Sustainability Manager

How LEED v4 Impacts Energy Professionals and Mirrors Broader Sustainability Trends. Dan LeBlanc Senior Sustainability Manager How LEED v4 Impacts Energy Professionals and Mirrors Broader Sustainability Trends Dan LeBlanc Senior Sustainability Manager dleblanc@yrgxyz.com LEED CERTIFICATION TRENDS MARKET SECTOR ADAPTATIONS Data

More information

BUILDING CODE BULLETIN

BUILDING CODE BULLETIN BUILDING CODE BULLETIN September 2010 06-BCB-007 Page 1 of 5 VENTILATION AIR FOR DWELLING UNITS IN MULTI-UNIT RESIDENTIAL BUILDINGS DISCUSSION This STANDATA has been developed to cover alternative methods

More information

LEED v4 Technical Bulletin Building Design + Construction

LEED v4 Technical Bulletin Building Design + Construction LEED v4 Technical Bulletin Building Design + Construction Background This document outlines Carboline s contributions towards available LEED v4 credits. Carboline is committed to developing and manufacturing

More information

COMMISSIONING, OPERATION AND MAINTENANCE

COMMISSIONING, OPERATION AND MAINTENANCE CHAPTER 9 COMMISSIONING, OPERATION AND MAINTENANCE THIS CHAPTER IS PROVIDED FOR REFERENCE ONLY. IT IS NOT ADOPTED AS A REQUIREMENT OF THE CODE. SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter

More information

Acoustic Performance

Acoustic Performance Acoustic Performance From LEED: BD& C for Schools IEQ P3 Requirements: Design classrooms and other core learning spaces to include sufficient sound-absorptive finishes for compliance with the reverberation

More information

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and & &01 GENERAL To be developed. All of the exceptions have to be coordinated. &02 SPECIAL USE AND OCCUPANCY &02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections &02.1.1 and &02.1.2.

More information

What s New in LEED O+M v4: Get Ready for the Future! A Presentation by The Sustainability Experts Leonardo Academy At NFMT Las Vegas

What s New in LEED O+M v4: Get Ready for the Future! A Presentation by The Sustainability Experts Leonardo Academy At NFMT Las Vegas What s New in LEED O+M v4: Get Ready for the Future! A Presentation by The Sustainability Experts Leonardo Academy At NFMT Las Vegas Today s Speakers Michael Arny, P.E., LEED AP President & Director of

More information

NONRESIDENTIAL ADDITIONS & ALTERATIONS 2010 CALGreen Checklist (per 7/1/2012 Supplement)

NONRESIDENTIAL ADDITIONS & ALTERATIONS 2010 CALGreen Checklist (per 7/1/2012 Supplement) NONRESIDENTIAL ADDITIONS & ALTERATIONS 2010 (per 7/1/2012 Supplement) Applies to Nonresidential Addition and Alteration projects without sleeping accommodations and meeting the following criteria: The

More information

Balco, Inc. Aluminum Expansion Joint Covers

Balco, Inc. Aluminum Expansion Joint Covers Balco, Inc. Aluminum Expansion Joint Covers Applicable Rating Systems: CI - Commercial Interiors RETAIL CI - Retail, Commercial Interiors Balco, Inc. Aluminum Joint Cover Systems Contributes to LEED Credits

More information

CONNECTICUT and NE-CHPS. September 15, 2014

CONNECTICUT and NE-CHPS. September 15, 2014 CONNECTICUT and NE-CHPS Carolyn Sarno Senior Program Manager, High Performance Buildings September 15, 2014 Brian D. Buckley High Performance Buildings Associate PRESENTATION SUMMARY 1. About NEEP 2. NE-CHPS

More information

Update on LEED v3. All projects registered after June 26, 2009 must be under the guidelines of LEEDv3. A LEEDv3 summary of changes:

Update on LEED v3. All projects registered after June 26, 2009 must be under the guidelines of LEEDv3. A LEEDv3 summary of changes: Update on v3 September 9, 2009 GP #7 The Green Building Rating system was recently updated and re-introduced April 27, 2009 as v3. This Green Piece will outline the major changes to the rating system and

More information

FRAMING INSPECTION GENERAL

FRAMING INSPECTION GENERAL FRAMING INSPECTION GENERAL 20 FRAMING INSPECTION GENERAL Tips Check habitable rooms for minimum light, ventilation and sanitation requirements. Check that stair framing meets headroom, width, and rise

More information

From: Tyler Adams, Mei Wu Acoustics

From: Tyler Adams, Mei Wu Acoustics Experts in acoustics, noise and vibration To: Jim Inglis, Stanford University John D. Donahoe, Stanford University Doug Sams, ZGF jinglis@stanford.edu jdonahoe@stanford.edu doug.sams@zgf.com From: Tyler

More information

EnviroLube LEED Point Contribution

EnviroLube LEED Point Contribution P.O. Box 3992 Grass Valley, CA 95945 800-700-3309 www.integratedlubeservices.com EnviroLube LEED Point Contribution This summary report is intended to inform any and all entities or parties on their EnviroLube

More information

You Can t Afford Discomfort. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

You Can t Afford Discomfort. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas You Can t Afford Discomfort Dan Int-Hout Chief Engineer, Krueger Richardson, Texas Where We Are Today: So You Want To Save Money? Things to consider: 1. First Cost 2. Energy cost 3. Occupant Salary costs

More information

Advanced Ventilation for Residential applications FBC Res 2010.

Advanced Ventilation for Residential applications FBC Res 2010. Advanced Ventilation for Residential applications FBC Res 2010. Course Description Review of the Residential Ventilation requirements in the Florida Building Code, Residential 2010. I. Introduction Dean

More information

2015 IBC Exit Systems

2015 IBC Exit Systems Objectives 2015 IBC Exit Systems Based on the 2015 International Building Code Upon completion, participants will be better able to: Determine those means of egress components that are defined as exits

More information