STANDARD FASCIA TABLE OF CONTENTS
|
|
- Morgan Parker
- 5 years ago
- Views:
Transcription
1 STANDARD FASCIA TABLE OF CONTENTS Standard Fascia Information, Specifications, and Dimensions...3 Standard Color Definition for Closed Fascias...4 Standard Color Definition for Open Fascias...5 FS0010PE Structural Spacer Connections...6 FS0020PE Sidewall Dimensions (Open Fascia)...7 FS0030PE Endwall Dimensions (Open Fascia)...8 FS0040PE Sidewall Dimensions (Closed Fascia)...9 FS0050PE Endwall Dimensions (Closed Fascia)...10 Fascia Bypass Girts...11 HA1010 Intermediate Low Eave...11 HA1020 Intermediate Post & Beam Endwall (Rake) - Closed Fascia 12 HA1025 Intermediate Post & Beam Endwall (Rake) - Open Fascia...13 HA1030 Intermediate High Eave...14 HA1050 Horizontal Spacer Erector Note...15 Fascia Inset Girts...16 HB1010 Intermediate Low Eave...16 HB1020 Intermediate Post & Beam Endwall (Rake) - Closed Fascia 17 HB1025 Intermediate Post & Beam Endwall (Rake) - Open Fascia...18 HB1030 Intermediate High Eave...19 Fascia Flush Girts...20 HC1010 Intermediate Low Eave...20 HC1020 Intermediate Post & Beam Endwall (Rake) - Closed Fasica 21 HC1025 Intermediate Post & Beam Endwall (Rake) - Open Fascia...22 HC1030 Intermediate High Eave...23 Fascia Post & Beam Endwall...24 HD1010 End High Eave...24 HD1020 End Low Eave...25 Fascia Corners...26 HE1010 Return To Main Building...26 HE1020 Outside Corner...27 HE1030 Sidewall Elevation...28 HE1040 Inside Corner SW...29 HE1050 Inside Corner EW...30 Fascia Secondary Members
2 HF1010 Intermediate Girts...31 HF1020 Sag Cable ( 20-0 Bays)...32 HF1030 Sag Cable ( 20-0 Bays)...33 HF1060 Sag Corner...34 Fascia Classic Roof (Closed Fascia)...35 HG1010 Sidewall Fascia sheeting w/ Eave Strut...35 HG1030 Sidewall Extended Fascia sheeting w/ (2) Eave Struts...36 HG1050 Endwall Fascia sheeting...37 HG1060 High Eave Fascia sheeting...38 Fascia Classic Roof (Open Fascia)...39 HH1020 Sidewall Fascia sheeting w/ Gutter...39 HH1040 Endwall Fascia sheeting...40 HH1050 High Eave Fascia sheeting...41 Fascia CFR Roof (Closed Fascia)...42 HI6020 Sidewall Fascia sheeting w/ Eave Strut...42 HI6040 Sidewall Extended Fascia sheeting w/ (2) Eave Struts...43 HI6060 Endwall Fascia sheeting...44 HI6070 High Eave Fascia sheeting...45 Fascia CFR Roof (Open Fascia)...46 HJ6020 Sidewall Fascia sheeting w/ Gutter...46 HJ6040 High Eave Fascia sheeting...47 HJ6050 Endwall Fascia sheeting...48 Fascia Trim...49 HK1020 Outside Corner w/ Accent Panel Face Panel...49 HK1050 Fascia Existing w/ Accent Panel Face Panel...50 HK1090 Fascia Termination Above Roof w/ Accent Panel Face Panel...51 HK1120 Fascia Termination Below Roof w/ Accent Panel Face Panel...52 HK1140 Soffit Corner Trim...53 HK1150 Fascia Cap Corner...54 HK1170 Fascia Soffit w/ Channel Return...55 HK1180 Parapet Gutter Interior Splice
3 STANDARD FASCIA INFORMATION, SPECIFICATIONS, AND DIMENSIONS 1. Fascias may be open or closed soffit with a closed with soffit being the standard condition. 2. Fascias MUST terminate at a sidewall or endwall column. 3. Fascia sheeting material, including face panel, back panel, and soffit panel is available in either Nucor Classic Wall, Nucor Reverse Classic Wall, Nucor Accent Wall, when supplied by Nucor Building Systems. Fascia sheeting may also be specified as supplied by others or not by Nucor Building Systems. In these cases, the weight of the sheeting and any specified deflection criteria must be supplied to Nucor Building Systems with the quote request and order documents. Contact the engineering team for assistance. 4. Fascia standard location is at/near the Eave height of a building. 5. With a Nucor CFR standing seam roof, a minimum of 18 is required above the highest portion of the roof structural to the top of a closed fascia to provide space for proper flashing. With a Nucor Classic Roof, a minimum of 10 is required for this condition. 6. The fascia clear dimension is taken from finish floor to bottom of the fascia structural. Additional information Nucor standard fascias is available at the Nucor Building Systems website at the below link. Standard Nucor Fascia The following pages provide standard details for projects with fascias. DATE: 03/11/15 BY: AAJ CHK: MDK 7.3.3
4 STANDARD COLOR DEFINITION FOR CLOSED FASCIAS DATE: 01/27/03 BY: CDM CHK: RJF FS0002PE.DWG 7.3.4
5 STANDARD COLOR DEFINITION FOR OPEN FASCIAS DATE: 01/27/03 BY: CDM CHK: RJF FS0003PE.DWG 7.3.5
6 FS0010PE STRUCTURAL SPACER CONNECTIONS DATE: 04/03/02 BY: CDM CHK: RJF FS0010PE.DWG 7.3.6
7 FS0020PE SIDEWALL DIMENSIONS (OPEN FASCIA) FS0020PE.DWG 7.3.7
8 FS0030PE ENDWALL DIMENSIONS (OPEN FASCIA) FS0030PE.DWG 7.3.8
9 FS0040PE SIDEWALL DIMENSIONS (CLOSED FASCIA) FS0040PE.DWG 7.3.9
10 FS0050PE ENDWALL DIMENSIONS (CLOSED FASCIA) FS0050PE.DWG
11 FASCIA BYPASS GIRTS HA1010 INTERMEDIATE LOW EAVE HA1010.DWG
12 HA1020 INTERMEDIATE POST & BEAM ENDWALL (RAKE) - CLOSED FASCIA HA1020.DWG
13 HA1025 INTERMEDIATE POST & BEAM ENDWALL (RAKE) - OPEN FASCIA HA1025.DWG
14 HA1030 INTERMEDIATE HIGH EAVE HA1030.DWG
15 HA1050 HORIZONTAL SPACER ERECTOR NOTE DATE: 04/03/02 BY: CDM CHK: RJF HA1050.DWG
16 FASCIA INSET GIRTS HB1010 INTERMEDIATE LOW EAVE HB1010.DWG
17 HB1020 INTERMEDIATE POST & BEAM ENDWALL (RAKE) - CLOSED FASCIA HB1020.DWG
18 HB1025 INTERMEDIATE POST & BEAM ENDWALL (RAKE) - OPEN FASCIA HB1025.DWG
19 HB1030 INTERMEDIATE HIGH EAVE HB1030.DWG
20 FASCIA FLUSH GIRTS HC1010 INTERMEDIATE LOW EAVE HC1010.DWG
21 HC1020 INTERMEDIATE POST & BEAM ENDWALL (RAKE) - CLOSED FASICA HC1020.DWG
22 HC1025 INTERMEDIATE POST & BEAM ENDWALL (RAKE) - OPEN FASCIA HC1025.DWG
23 HC1030 INTERMEDIATE HIGH EAVE HC1030.DWG
24 FASCIA POST & BEAM ENDWALL HD1010 END HIGH EAVE HD1010.DWG
25 HD1020 END LOW EAVE HD1020.DWG
26 FASCIA CORNERS HE1010 RETURN TO MAIN BUILDING HE1010.DWG
27 HE1020 OUTSIDE CORNER HE1020.DWG
28 HE1030 SIDEWALL ELEVATION HE1030.DWG
29 HE1040 INSIDE CORNER SW HE1040.DWG
30 HE1050 INSIDE CORNER EW HE1050.DWG
31 FASCIA SECONDARY MEMBERS HF1010 INTERMEDIATE GIRTS HF1010.DWG
32 HF1020 SAG CABLE ( 20-0 BAYS) HF1020.DWG
33 HF1030 SAG CABLE ( 20-0 BAYS) HF1030.DWG
34 HF1060 SAG CORNER HF1060.DWG
35 FASCIA CLASSIC ROOF (CLOSED FASCIA) HG1010 SIDEWALL FASCIA SHEETING W/ EAVE STRUT HG1010.DWG
36 HG1030 SIDEWALL EXTENDED FASCIA SHEETING W/ (2) EAVE STRUTS HG1030.DWG
37 HG1050 ENDWALL FASCIA SHEETING HG1050.DWG
38 HG1060 HIGH EAVE FASCIA SHEETING HG1060.DWG
39 FASCIA CLASSIC ROOF (OPEN FASCIA) HH1020 SIDEWALL FASCIA SHEETING W/ GUTTER HH1020.DWG
40 HH1040 ENDWALL FASCIA SHEETING HH1040.DWG
41 HH1050 HIGH EAVE FASCIA SHEETING HH1050.DWG
42 FASCIA CFR ROOF (CLOSED FASCIA) HI6020 SIDEWALL FASCIA SHEETING W/ EAVE STRUT HI6020.DWG
43 HI6040 SIDEWALL EXTENDED FASCIA SHEETING W/ (2) EAVE STRUTS HI6040.DWG
44 HI6060 ENDWALL FASCIA SHEETING DATE: 12/29/17 BY: EGB CHK: SDF HI6060.DWG
45 HI6070 HIGH EAVE FASCIA SHEETING DATE: 12/29/17 BY: EGB CHK: SDF HI6070.DWG
46 FASCIA CFR ROOF (OPEN FASCIA) HJ6020 SIDEWALL FASCIA SHEETING W/ GUTTER DATE: 12/29/17 BY: EGB CHK: SDF HJ6020.DWG
47 HJ6040 HIGH EAVE FASCIA SHEETING DATE: 12/29/17 BY: EGB CHK: SDF HJ6040.DWG
48 HJ6050 ENDWALL FASCIA SHEETING DATE: 12/29/17 BY: EGB CHK: SDF HJ6050.DWG
49 FASCIA TRIM HK1020 OUTSIDE CORNER W/ ACCENT PANEL FACE PANEL HK1020.DWG
50 HK1050 FASCIA EXISTING W/ ACCENT PANEL FACE PANEL HK1050.DWG
51 HK1090 FASCIA TERMINATION ABOVE ROOF W/ ACCENT PANEL FACE PANEL HK1090.DWG
52 HK1120 FASCIA TERMINATION BELOW ROOF W/ ACCENT PANEL FACE PANEL HK1120.DWG
53 HK1140 SOFFIT CORNER TRIM HK1140.DWG
54 HK1150 FASCIA CAP CORNER HK1150.DWG
55 HK1170 FASCIA SOFFIT W/ CHANNEL RETURN HK1170.DWG
56 HK1180 PARAPET GUTTER INTERIOR SPLICE HK1180.DWG
TABLE OF CONTENTS 4.8.1
TABLE OF CONTENTS General Notes...2 Roof Structural Details...3 AR0010 Low Eave, Bypass Girts...3 AR0020 Low Eave, Inset Girts...4 AR0030 Low Eave, Flush Girts...5 AR0040 High Eave, Bypass Girts...6 AR0060
More informationPRODUCT AND ENGINEERING MANUAL
TABLE OF CONTENTS Table of Contents... 1 General Information... 3 Secondary Framing... 4 BJ0030 Purlin Connection to Existing Non-Nucor Building (W/ Existing Frame) 4 BJ0040 Purlin Connection to Existing
More informationHIGH EAVE DETAILS...12
TABLE OF CONTENTS CF0030PE Building Elevation...3 LOW EAVE DETAILS...4 ED6010 Standard Low Eave (Gutter) Eave Strut...4 ED6040 Low Eave (Gutter) @ Masonry Or Concrete Eave Strut...5 ED6300 Low Eave (Horizontal
More informationGENERAL FRAME INFORMATION
GENERAL FRAME INFORMATION TAPERED BEAM, CLEAR SPAN, GABLE 1. Tapered Beam frames are an excellent solution for small buildings under 70 feet in width. 2. Straight columns provide maximum floor space and
More informationACCESSORIES TABLE OF CONTENTS
ACCESSORIES TABLE OF CONTENTS Framed Opening Features...3 Vertical Lift-High Lift Doors...4 Walkdoor Information...5 Pre-Assembled Walk Door Features...5 Pre-Assembled Walk Door Product Description...5
More informationTABLE OF CONTENTS 4.5.1
TABLE OF CONTENTS General Mezzanine Information and Specifications... 2 SM0010PE Mezzanine Plan Information... 3 Information Required for Mezzanine Structures... 4 Floor And/Or Mezzanine Design Information
More informationProfessional Engineering Services. The Brand of Choice
The Brand of Choice Nucor Building Systems, a division of Nucor Corporation, is one of the most flexible and diverse building manufacturers in operation today. Nucor Corporation is a Fortune 500 Company,
More informationNUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS
NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS Nucor VR16 II Vertical Rib Standing Seam Roof System...2 Nucor VR16 II Property and Span Tables...3 Standard Details...5 ED3010PE - Gutter...5
More informationChapter 53: Endwall Overhang(s) Only - Enclosed
Chapter 53: Endwall Overhang(s) Only - Enclosed Most Common Mistakes: 1. Incorrect eave height. 2. Placing standard heel end trusses at same height as interior trusses. 3. Fascia board top edges not bevel
More informationCRANES TABLE OF CONTENTS
CRANES TABLE OF CONTENTS General Crane Information...2 Crane Tie-Back Detail...3 AH0008 Crane Tie-Back Connection...3 Top Running Bridge Crane Bracket Details...4 AH0010 - Runway Beam to Bracket Connection...4
More informationChapter 25: Sliding Door Opening Framing
Chapter 25: Sliding Door Opening Framing Most Common Mistakes: 1. Locating header at incorrect height. 2. Failure to install siding backing. 3. Track board not installed, at wrong height, or cut to incorrect
More informationLoseke Technologies, Inc. p r e s e n t s
p r e s e n t s A Tour of PrecisionPlus Building Software for the Future Introduction would like to take this opportunity to thank you for your interest in PrecisionPlus, the leading metal building design,
More informationCOLQUITT COUNTY BOARD OF COMMISSIONERS 101 East Central Avenue
COLQUITT COUNTY BOARD OF COMMISSIONERS 101 East Central Avenue TERRY R. CLARK Chairman LUKE STRONG, JR District 1 Commissioner CHRIS HUNNICUTT District 2 Commissioner MARC DEMOTT District 3 Commissioner
More informationSECTION PRE-ENGINEERED METAL BUILDING
SECTION 13121 PRE-ENGINEERED METAL BUILDING PART 1 GENERAL 1.01 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals required to design, fabricate, deliver to project site, and erect
More informationADP-2 LINER PANEL ERECTION GUIDE
ADP-2 LINER PANEL ERECTION GUIDE NOTE: See back side of cover for latest changes to this manual. BEHLEN MFG. CO. COLUMBUS, NE 68601 TECHNICAL INFORMATION 55063 Rev. 10/2/17 11/05/04 NOTE: If pink sheets
More informationPanel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing
EXTERIOR BASE DETAIL (FLUSH) EXTERIOR BASE DETAIL (OVERHANG) Base Trim with Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint Sealant Marriage Bead to Vertical Panel Joint Above and Below Z Flashing
More informationADP-1 LINER PANEL ERECTION GUIDE
ADP-1 LINER PANEL ERECTION GUIDE NOTE: See back side of cover for latest changes to this manual. BEHLEN MFG. CO. COLUMBUS, NE 68601 TECHNICAL INFORMATION 55062 Rev. 8/23/12 NOTE: If pink sheets are included
More informationtypical section 1:50 Important:
00 Typical ventilated facade installation mounted with top hat channels onto external walls, awning soffit and fascia. 00 Wall panels are shown in varying heights, having open joints for ventilation of
More informationFor Metal Roofing Systems Fascia, Mansards,& Soffits
HIGGINS STEEL ROOFING SERIES 2000 STANDING SEAM DETAIL MANUAL For Metal Roofing Systems Fascia, Mansards,& Soffits Wall Panels/Siding HIGGINS CONSTRUCTION & SUPPLY CO. 3801 U. S. 50 HILLSBORO, OHIO 45133
More informationCentral Texas Metal Roofing Supply Co., Inc NET COVERAGE SHEET WIDTH
1 2 " 1 24" GAUGE PANEL FINISH NET COVERAGE SHEET WIDTH WEIGHT PER SQ. 26 5 Vee GALVALUME 24 26 3/8 95.00 PRICE PER SQ. PRICE PER LINEAR FOOT PANEL PRICING: 1. Price per Square is based on 26 3/8 sheet
More informationFACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET
KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV
More informationCentral Texas Metal Roofing Supply Co., Inc 36" SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 40 ¼ 40 ¼ NET COVERAGE
3 4 " 9" 36" GAUGE PANEL FINISH 26 26 26 26 24 24 24 24 FRONTIER RIB LAP GUARD FRONTIER RIB LAP GUARD FRONTIER RIB LAP GUARD LAP GUARD LAP GUARD GALVALUME GALVALUME SMP SMP GALVALUME GALVALUME KYNAR500
More informationCentral Texas Metal Roofing Supply Co., Inc 36" NET COVERAGE SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 40 ¼ 40 ¼
36" 1 2 " 6" GAUGE PANEL FINISH NET COVERAGE SHEET WIDTH WEIGHT PER SQ. 26 26 26 26 24 24 24 24 TEXAS RIB CHANNEL GUARD TEXAS RIB CHANNEL GUARD TEXAS RIB CHANNEL GUARD CHANNEL GUARD CHANNEL GUARD GALVALUME
More informationMustafa & Kamal Ashraf Trading Co. PRE ENGINEERED BUILDING & STRUCTURAL STEEL MANUFACTURING TOTAL SOLUTION IN DESIGN, FABRICATION & INSTALLATION
Mustafa & Kamal Ashraf Trading Co. PRE ENGINEERED BUILDING & STRUCTURAL STEEL MANUFACTURING TOTAL SOLUTION IN DESIGN, FABRICATION & INSTALLATION ISO 9001 Project: Logistic Extension Client: Khimji Ramdas
More informationB. Shop Drawings: For the following metal building system components. Include plans, elevations, sections, details, and attachments to other work.
SECTION 133419 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationMETAL BUILDING SYSTEM SPECIFICATIONS
METAL BUILDING SYSTEM SPECIFICATIONS 1. GENERAL 1.1. SCOPE 1.1.1. The attached specifications cover the standard materials and components used in the design and fabrication of Miller Building Systems,
More informationPRE-ENGINEERED METAL BUILDING SYSTEM
PRE-ENGINEERED METAL BUILDING SYSTEM PART 1 GENERAL 1.1 SUMMARY A. The building shall include all primary and secondary structural framing members, connection bolts, roof and wall covering, flashing, gutter,
More informationCentral Texas Metal Roofing Supply Co., Inc SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼
GAUGE PANEL FINISH NET COVERAGE 26 26 26 26 U PBU U PBU GALVALUME GALVALUME SMP SMP (NOTE 1) SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ WEIGHT PER SQ. 95.00 95.00 95.00 95.00 24 24 24 24 24 24 U PBU U PBU U PBU GALVALUME
More informationGeneral. 2. Design. 3. Anchor Bolts And Foundations. 4. Drawings. 5. Structural Framing. 6. Roof Covering Nucor Classic Roof Panel
The following Nucor Building Systems Specification Guide provides the owner or design professional a detailed description of all standard Nucor Building Systems (NBS) products. This guide is designed to
More informationTABLE OF CONTENTS PRODUCT CATALOGUE fax OVERVIEW PBR 7.2 LONGSPAN ECONORIB
PRODUCT CATALOGUE www.metroll.us sales@fontana.metroll.com ph. 909.823.7663 fax 909.693.5153 TABLE OF CONTENTS OVERVIEW PBR Product Overview and Color Charts Panel Information and Trim 7.2 LONGSPAN ECONORIB
More informationDistances are not shown to scale. Existing porch. Community. Building. Distances are not shown to scale
patio and deck 00 Building Two story Four-plex Entrance 0 0 00 Building Single Story Duplex 0 patio Contact Information: Owner: Housing Authority of Yamhill County, NE Dunn Place, McMinnville, OR 9. Contact:
More informationPebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details
Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier Typical Details (THIS PAGE INTENTIONALLY LEFT BLANK Pebbletex Wall System Class PB Exterior Insulation
More informationPRODUCT DESCRIPTION ACCESSORIES. Canopies
An overhanging or projecting roof structure off the sidewall or endwall with the extreme end usually unsupported. Mainly used for aesthetic application or to cover entrance or walkway. Options: Face Panel
More informationPrimary Concerns and Defects
Primary Concerns and Defects Primary Concerns and Defects: Home Inspector Observations: Where to Look. What to Look For. What Observed condition may mean. Primary Concerns The points to be inspected per
More informationChapter 32 - Garage. June 2015 Garages 32-1
Chapter 32 - Garage Contents Chapter 32 - Garage... 32-1 Foundation... 32-3 Walls... 32-3 Roof Framing... 32-4 Roofing... 32-4 Exterior Dow Board... 32-5 Doors... 32-5 Siding... 32-5 Gutters... 32-6 Painting...
More informationProject Findings: Appendix 2
NSF Final Report CMMI-1034874 Project Findings: Appendix 2 Selected Damage Photos of Engineered Buildings PART 1. St. Louis Gonzague Cafeteria Building Civil Engineering and Engineering Mechanics Department
More informationConnection Design Assistance Manual
Connection Design Assistance Manual Architectural Precast Concrete Glass Fiber Reinforced Concrete Cast Stone Architectural Precast Association 6710 Winkler Road, Suite 8 Fort Myers, FL 33919 Phone: 239-454-6989
More informationLesson 6 The Focus of the Lesson is: Use other predefined shapes. Have Multiple Frames Types at same Frame Line. Open a wall for material not by VP.
The Focus of the Lesson is: Use other predefined shapes. Have Multiple Frames Types at same Frame Line. Open a wall for material not by VP. The following pages are actual VP Command screens with instruction
More information* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request.
is a concealed fastener architectural standing seam roof panel. The panels are easily installed over decking, utilizing metal clips. panels are ideally suited for decorative mansard, fascia and roofs.
More informationSECTION PRE - ENGINEERED METAL BUILDING MATERIALS
1. GENERAL: 1.01 DESCRIPTION: This supplier shall furnish materials for a Pre - Engineered Steel Structural System, for a new Cafetorium, Gymnasium, Science Labs and Classroom Building, complete with roof
More information1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights
1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights These 1 Exam Prep tabs are based on the 2012 Sheet Metal and Air Conditioning Contractors' National Association, Inc., seventh edition.
More informationReference Information for Creating Successful Projects
Systems Guide Varco Pruden Buildings Systems Guide Reference Information for Creating Successful Projects A Division of BlueScope Buildings North America 1 Varco Pruden Buildings 2 Systems Guide Varco
More informationPRODUCT DESCRIPTION. Frame Types Available PRIMARY FRAMING. Gable Symmetrical
: A ridged (double slope) building in which the ridge is in the center of the building. Gable: The triangular portion of the endwall from the level of the eave to the ridge of the roof. Gauge: Finish:
More informationRelease Notes Version 5.1.0
This version replaces version 5.0.0 or earlier Corrected the following Bugs and Errors: 1) Changed maximum length of support beams at open areas from 33'-4 to 40'-0" to match the allowed maximum bay spacing.
More informationBRYAN COUNTY SCHOOLS DECEMBER 2013 McALLISTER ELEMENTARY SCHOOL - RICHMOND HILL NORTH BRYAN COUNTY 3-5 SCHOOL PEMBROKE 100% GMP DOCUMENTS (1/14/2014)
SECTION 13 34 19 - METAL BUILDING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationLesson 7 The Focus of this Lesson is:
The Focus of this Lesson is: Input an Endwall-to Endwall Roof Height Change (Low Building for Office, High Building for Manufacturing) Auxiliary Bracing (Portal Brace) Straight Columns Wide Bay Trussed
More informationContents DESIGNER S STRUCTURAL PRODUCTS GUIDE. Tegral Purlins & Rails
DESIGNER S STRUCTURAL PRODUCTS GUIDE Introduction Contents Tegral Purlins & Rails Zeta Purlins & Rails Zeta Purlins page 8 Zeta Rails page 15 Zeta Purlin & Rail Cleats page 22 Zeta 2 Purlins & Rails Zeta
More informationPROLOK EAVE PROLOK ROOFING PANEL ROOFING NAIL
EAVE ROOFING NOTE: ROOF PITCH IS REQUIRED FOR FABRICATION LOW SLOPE ADD SEALER TAPE ROOFING NAIL 2x4 SUB- 2x8 EAVE TRIM 1. Install the eave trim using roofing nails. 2. If sealer tape is being used, install
More informationPricing Report Elite /26/ A
Pricing Report Elite 4.9 11/26/2014 31372 A Buyer acknowledges and agrees that this quotation is not valid for plan and specification projects since it is based on the Manufacturer's product standards
More informationKirby Building Systems Inc., A Nucor Company 124 Kirby Drive P O Box 390 Portland, TN Tel:
Kirby Building Systems Inc., A Nucor Company 124 Kirby Drive P O Box 390 Portland, TN 37148 Tel: 615 325 4165 www.kirbybuildingsystems.com MIAMIDADE COUNTY APPROVED roduct catalog KBS Form# 0411-25 Contents
More informationAcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details
Typical Details AcroWall-ES System Class PB Exterior Insulation and Finish System providing a primary moisture barrier 1. Typical AcroWall-ES System Application 2. Typical Aesthetic Reveal 3. Typical Window
More informationSIDEWALL/ENDWALL STANDING SEAM TRIMS SIDEWALL/ENDWALL CROSS SECTION NTS SIDING OR OTHER WALL CLADDING, TYP LOW PROFILE FASTENER, TYP
CHIMNEY FLASHING CROSS SECTION 1. CHIMNEY FLASHING TRIM IS DESIGNED TO FLASH AROUND CHIMNEYS AND LARGE PENETRATIONS (E.G. SKYLIGHTS). CH1 AND CH7 ARE INTENDED FOR USE WITH MOST EXPOSED FASTENER AND STANDING
More informationFOR FIELD USE PLEASE DISTRIBUTE TO THE ERECTION CREW
COVER INSTRUCTIONS FOR INSTALLING NBS CLASSIC ROOF FOR FIELD USE PLEASE DISTRIBUTE TO THE ERECTION CREW WATERLOO, IN 305 Industrial Parkway Waterloo, IN 46793 Phone: 260-837-7891 Fax: 260-837-7384 SWANSEA,
More informationFACE CFP - HORIZONTAL PANELS - OPTION 'B'
- Vertical Transitions 12F - H10.3 VHB TAPE 5.000" 127.0mm 5" FORMED TRANSITION STRIP w/ FLAT FACE CFP - - OPTION 'B' H10.3 CONCEALED FASTENED Panel Index 12F - H0 BASE DETAILS JOINT DETAIL PARAPET ROOF
More informationPrestige Series 12. Installation guide
Prestige Series 12 Installation guide PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS Section Page Notes to Designer/User.................... 2 Panel Options............................. 3 Panel Details..............................
More informationPORCH PLAN. Existing House. New Porch. Page A.1. Boxed Beams. 5/4x6 Cedar Decking. Roof Overhang. Wood Columns. Hip Roof. Step
Porch Plan 28 68 2'-0" 7'-8" 2'-0" 7'-0" PORCH PLAN SCALE: /4" = '-0" CD24 0 SECT D A.6 7 /4" 7 /4" Boxed Beams Existing House 23'-2 /4" 30 68 New Porch Step Wood Columns 8'-0" 2'-0 /2" 2'-0 /2" 8'-0"
More informationIntroduction. Massing and Overall Form. Catalina. Catalina is a 111 lot, single-family home community by Costain Arizona, Inc.
Introduction Catalina is a 111 lot, single-family home community by Costain Arizona, Inc. Massing and Overall Form This neighborhood comprises single-story, asymmetrical plan homes with asymmetrical facades.
More informationBuilt to Last a Lifetime
Built to Last a Lifetime Welcome to Lincoln 2 This brochure will introduce you to Lincoln Steel Buildings from the ground up starting with the framing of the building all the way to the roof and finally
More informationArchitectural Wall Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is
More informationStructural Engineering
Structures can be classified based on deformation and type of primary load carried [i.e. Axial (tensile, compressive), flexure, shear and torsion] and their combinations. In order to determine the type
More informationS BI COM P ON E NT CA T ALOG
SBI METAL BUILDINGS & COMPONENTS S BI COM P ON E NT CA T ALOG Date: 03 / 16 / 2017 COMMERCIAL PRODUCTS Commercial Panels and Trim Cee, Zee, Eave Struts, Angle, Channel, and Clips Accessories FT 0 1 2 3
More informationNEW CONSTRUCTION ADDENDUM TO COA APPLICATION
NEW CONSTRUCTION ADDENDUM TO COA APPLICATION Property Owner Address City, ST Zip Phone Fax Street Address Tax Parcel Historic ID C N P F I HPC HDC Staff Project Description: Check all that apply. Primary
More informationCONTOUR CORRUGATED PANEL
CONTOUR CORRUGATED PANEL Table of Contents SECTION PAGE Designer Notes............................................... 1 Panel Net Coverage / Fasteners.................................... 2 ROOF Details
More informationGLOSSARY OF TERMS. Approval Plans - Approval plans may include framing plans, elevations, and sections through the building for approval of the buyer.
GLOSSARY OF TERMS A Aluminum Tape: Tape used to cover the top end of a multiwall sheet to prevent water, dust, debris, and bugs from entering flutes. ANSI - American National Standards Institute Anchor
More informationLesson 16: Masonry Walls; Wind (Spandrel) Beams:
Lesson 16: Masonry Walls; Wind (Spandrel) Beams: Wall material Not By VP Wind/Spandrel Beams In this lesson we will discuss the various methods of inputting Wall Material Not By Varco-Pruden (NBVP). In
More information4. Standard Trim Profiles Includes: Flat Sheets & Die Formed Ridge Caps
Table of Contents 4. Standard Trim Profiles Includes: Flat Sheets & Die Formed Ridge Caps Page Mark Description Condition BASE TRIM 3 FBBTD Base Trim (Box) Standard 3 FBBTC Base Trim (Return Leg) Customer
More informationRESPONSES TO QUESTIONS. March 1, 2018
MPA CONTRACT NO. H275-C1 HANSCOM AIRCRAFT RESCUE FIRE FIGHTING / UNITED STATES CUSTOMS AND BORDER PROTECTION FACILITY L.G. HANSCOM FIELD, BEDFORD, MASSACHUSETTS RESPONSES TO QUESTIONS March 1, 2018 The
More informationSingle Layer Wall Install Instructions
s ilverco te. c o m Single Layer Wall Install Instructions FOR NEW CONSTRUCTION Read the entire instructions before you begin. Before you begin: Locate the shipping pallet that contains the installation
More information/CEC BuyLine 9109 C ECO B UILDING S YSTEMS
9/CEC BuyLine 909 C ECO B UILDING S YSTEMS A R C H I T E C T U R A L R E S O U R C E Rigid Frame Structural Systems Metal Roof Panels Rigid Frame Multi-Span (with Interior Column) Endpost End Frame (Bearing)
More informationTable of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5
Table of Contents Section Page Notes to Designer/User...................1-2 Map of Typical Roof Conditions..............3 Fastener Placement........................4 Fastener Selection.........................5
More informationPIPE. Central Texas Largest Distributor. Structural Steel, Pipe and Metal Building Components
Central Texas Largest Distributor Structural Steel, Pipe and Metal Building Components PIPE Waco Location P.O. Box 154485 913 South Loop Dr. Waco Texas 76705 Local - 254-754-2611 Bryan Location 9401 E.
More informationSTRUCTURAL ABBREVIATIONS S-001 GENERAL NOTES CONCRETE MASONRY NOTES DESIGN NOTES SOF NSWG-10 UAS SUPPORT FACILITY FY 2016 MILCON P-225
GENERAL NOTES DESIGN NOTES (CONTINUED) FOUNDATION NOTES STRUCTURAL ABBREVIATIONS CONCRETE MASONRY NOTES DESIGN NOTES S-001 CONCRETE NOTES COLD-FORMED STEEL FRAMING NOTES PRE-ENGINEERED METAL BUILDING NOTES
More informationButte County Fire Department Fire Prevention Bureau 176 Nelson Avenue Oroville, CA Office (530)
2016 CBC Chapter 7A and CRC Section R337 (The use of paints, coatings, stains, or other surface treatments are not an approved method of protection as required in this chapter.) The Wildland Urban Interface
More information6" TRIM AT GARAGE DOORS (TYP) 6" TRIM (TYP) OPTIONAL PATIO DOOR
GABLE END x0 TRIM (TYP) A6. PTD. ALUM GUTTER (TYP) MODEL 67 - OVATION MODEL - BRAVO 0.670.7 09'- /8" 00'-0" " WATER 6" CORNER TRIM (TYP) 6" TRIM AT GARAGE DOORS (TYP) OPTIONAL PATIO DOOR AMERICAN TRADITIONAL
More informationC-1.0 PRINT DATE 07/20/17
N EISTING METAL BUILDING EISTING CONCRETE EISTING BOLLARDS T.B.M F.F 100.0' T.O.C 100.1' EISTING BOLLARDS EISTING 1224 BUILDING TO BE RELOCATED PRIOR TO CANOPY INSTALLATION (BY OWNER) D TO O SL SLOPE TO
More informationDugout Covers Specifications
Section 1 - General Dugout Covers Specifications 1.01 Work Included Metal building systems, complete with structural framing (Columns, rafters, struts, purlins, girts, bracing), and optional prefinished
More informationcomponents your source. exceptional service
components your source. exceptional service VP Components, established in 1998, serves customers across North America by providing building components and accessories designed to meet the needs of the
More informationSECTION NON-STRUCTURAL METAL FRAMING
SECTION 09 22 16 PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories
More informationSHURLOC 150 STANDARD DETAILS
OVER WOOD DECK STANDARD DETAILS Austin - Headquarters/Sales Office 830 Sagebrush Drive Austin, TX 78758 (512) 452-1515 (800) 428-7412 Fax (512) 833-7499 www.ctmrs.com email: info@ctmrs.com Seguin - Plant/Sales
More informationATTACHMENT 2 DRC Page 1 of 13
Page 1 of 13 CLEAR GLASS 7' - 6" SPANDREL GLASS CLEAR GLASS SOLID PHENOLIC PANEL MEAT PREP 206 EMPLOYEE LOCKERS 181 VARIES 8' - 1" 2' - 9" 3' - 1" 2' - 8" 2' - 5" 0'-0" 19' - 6" SECTION @ SOUTH WALL Scale:
More information900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900
CS-PJ-01-900 CS-DS-01-900 CS-PJ-02-900 CS-EL-01-900 CS-EL-02-900 CS-EL-03-900 CS-EL-04-900 CS-RD-01-900 CS-RD-02-900 CS-RD-03-900 CS-EV-01A-900 CS-EV-01B-900 CS-EV-02A-900 CS-EV-02B-900 CS-EV-03A-900 CS-EV-03B-900
More information12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS
CONCEALED FASTENED PANELS CFP-12 PANEL INDEX 12 - V0 BASE DETAILS HORIZONTAL JOINT DETAIL PARAPET ROOF DETAIL INSIDE CORNER DETAIL OUTSIDE CORNER DETAIL SOFFIT DETAIL WINDOW JAMB DETAIL WINDOW HEAD DETAIL
More informationELEVATION GENERAL NOTES: 1. ALL PAINT / FINISH SYMBOL DEFINITIONS FOUND ON A8.1. 2. ALL NEW GLAZING WITHIN 18" OF GROUND OR ADJACENT TO DOOR(S) TO BE TEMPERED. 3. REMOVE ALL EXISTING METLA COPING CAPS
More informationARB Guidelines for approval of Detached Garage designs in Ashborough East
ARB Guidelines for approval of Detached Garage designs in 1. SUBMITTAL, DESIGN REVIEW, and APPROVAL PROCESS: a. All submitted plans must be accompanied by the standard Architectural Review Board (ARB)
More informationStudent Services & Classroom Addition
SECTION 074243 - METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationRESIDENTIAL LIGHT GAUGE APPLICATION GUIDE
Our Name Says It All RESIDENTIAL LIGHT GAUGE APPLICATION GUIDE Lebanon, PA 888.339.0059 Bridgton, ME 800.677.2060 Howe, IN 866.562.3782 www.everlastroofing.com Residential Light Gauge Table of Contents
More informationSECTION METAL BUILDING SYSTEMS
SECTION 13 3419 PART 1 GENERAL 1.01 SECTION INCLUDES A. Manufacturer-engineered, shop-fabricated structural steel building frame. B. Insulated Metal wall and roof panels including gutters and downspouts.
More informationGENERAL ENGINEERING TERMS AS APPLIED TO BUILDINGS
Page 1 of 7 GENERAL ENGINEERING TERMS AS APPLIED TO BUILDINGS This glossary was written to help individuals become more familiar with some of the common engineering terms used by the building industry.
More informationPersonal CrossFit Gym. Detached dwelling
Personal CrossFit Gym Detached dwelling The client came to the architect to design a detached garage with a CrossFit gym on the second floor. The garage was to be able to store an antique Jeep, which the
More informationPROJECT IDEA CATALOG. FREE! Take one. Get inspired! 84LUMBER.COM
PROJECT IDEA CATALOG FREE! Take one. Get inspired! 84LUMBER.COM Gambrel Barns These oversized barns maximize your storage space. They re easy to build, using our engineered truss brackets, providing a
More informationCR# August 20, 2015
SECTION 07 40 00 - METAL ROOF AND WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Factory-formed and field-assembled, standing-seam metal roof panels. 2. Factory-formed and field-assembled,
More informationSIDEWALL/ENDWALL EXPOSED FASTENER TRIMS. Details master.dwg 2/15/2017 GULF COAST SUPPLY & MFG., LLC
CHIMNEY FLASHING CROSS SECTION 1. CHIMNEY FLASHING TRIM IS INTENDED TO FLASH AROUND CHIMNEYS AND LARGE PENETRATIONS. OTHER USE MAY BE ACCEPTABLE IF DESIGNER DETERMINES FITNESS OF USE. 3. LARGE PENETRATIONS
More informationCarpentry/Carpenter CIP Task Grid
Secondary Task List 100 SAFETY/OCCUPATIONAL ORIENTATION 101 Identify and follow all basic safety practices and procedures. 102 Identify and follow all lab safety practices and procedures. 103 Identify
More informationCONSTRUCTION IMPORTANT TERMS AND FACTS CHAPTER 15
CONSTRUCTION IMPORTANT TERMS AND FACTS CHAPTER 15 Copyright 2004 CONSTRUCTION The following are twenty key construction components and basic facts that are to be considered high priority. Please refer
More informationEXTERIOR SIDING CONDITION SURVEY
EXTERIOR SIDING CONDITION SURVEY FOR FARRWOOD 2 CONDOMINIUMS 49-176 FARRWOOD DRIVE HAVERHILL, MA APRIL 2016 c/o PROPERTY MANAGEMENT OF ANDOVER, INC. P.O. BOX 488 ANDOVER, MA 01810 213 WEST STREET, MILFORD,
More information