1 00 Typical ventilated facade installation mounted with top hat channels onto external walls, awning soffit and fascia. 00 Wall panels are shown in varying heights, having open joints for ventilation of the cavity which is open along the full extent of bottom and top edges Important: Parklex panels incorporate a balancing timber veneer to the back of the panel in order to balance the differential in expension rates between core and facing materials, thereby eliminating buckling of panels under changes in atmospheric conditions. However, buckling of panels may still occur if Parklex is installed incorrectly with differing exposure between front and rear faces of panels. Therefore, Parklex must be installed with a fully ventilated cavity as depicted in these drawings or an equivalent system, such that temperature, humidty and air movement are equalised between both faces of panels. A ventilated cavity also aids in the control of moisture and heat through the external building envelope typical section :0

2 mm thick panel fixed to top hat with mm wide x.mm thick M VHB continuous adhesive tape.. 0mm wide open joints between panels.. Line of floors and ceiling behind.. Bottom edge of wall panels (behind awning fascia).. Indicative window. typical elevation :0 - conceal fixed with M tape dwg no. parklex-00/

3 mm thick panel fixed to top hat with mm wide x.mm thick M VHB continuous adhesive tape mm wide x mm deep x.mm bmt top hat channels fixed vertically at maximum 0mm centres. 0-0mm long x mm deep spacer top masonry wall, spaced 00mm at ends and maximum 00mm intermediate centres. 0mm wide joint (not filled or backed). Line of floors and ceiling behind Bottom edge of wall panels (behind awning fascia). Indicative window. typical elevation :0 showing support framings - conceal fixed with M tape dwg no. parklex-00/

4 . mm thick panel fixed to top hat with mm wide x.mm thick M VHB continuous adhesive tape... 0mm wide x mm deep x.mm bmt top hat channels fixed vertically, spaced at maximum 0mm centres mm long x mm deep spacer top masonry wall, at 00mm maximum centres.. Impermeable non-reflective sarking lapped 0mm at joints, sealed at joints and perimeter with continuous bead of Sikaflex Pro... 0mm wide joint (not filled or backed).. Indicative metal sheet parapet cladding.. Indicative flashing.. 0. Indicative wall/ parapet framing. Indicative box gutter.. Indicative roofing.. Indicative structural steel.. Indicative substrate walls.. Indicative internal ceiling and wall linings. 0 typical section detail : parapet wall - conceal fixed with M tape dwg no. parklex-00/

5 0 0 typical jamb detail : typical head detail :. mm thick panel fixed to top hat with mm wide x.mm thick M VHB continuous adhesive tape.. 0mm wide x mm deep x.mm bmt top hat channels fixed vertically, spaced at maximum 0mm centres mm long x mm deep spacer top masonry wall, at 00mm maximum centres.. Impermeable non-reflective sarking lapped 0mm at joints, sealed at joints and perimeter with continuous bead of Sikaflex Pro.... 0mm wide joint (not filled or backed). Flashing.. Caulking.. Indicative wall framing. 0. Indicative window.. Indicative window sill... Indicative sill board. Indicative substrate walls.. Indicative internal ceiling and wall linings. typical sill detail : - conceal fixed with M tape dwg no. parklex-00/

6 ..... mm thick panel fixed to top hat with mm wide x.mm thick M VHB continuous adhesive tape. 0mm wide x mm deep x.mm bmt top hat channels fixed vertically, spaced at maximum 0mm centres mm long x mm deep spacer top masonry wall, at 00mm maximum centres. Impermeable non-reflective sarking lapped 0mm at joints, sealed at joints and perimeter with continuous bead Sikaflex Pro... 0mm wide joint (not filled or backed). Flashing.. Caulking.. Indicative wall framing. 0.. Indicative concrete edge beam. Indicative wall substrate.. Indicative internal ceiling and wall linings. 0 - conceal fixed with M tape typical section detail : dwg no. parklex-00/

7 ... mm thick panel fixed to top hat with mm wide x.mm thick M VHB continuous adhesive tape. 0mm wide x mm deep x.mm bmt top hat channels fixed vertically, spaced at maximum 0mm centres mm long x mm deep spacer top hat or block fixed through sarking and backing sheet to plate, nogging or girt (provide masonry wall, spaced at 00mm maximum centres... Impermeable non-reflective sarking lapped 0mm at joints, sealed at joints and and perimeter with continuous bead Sikaflex Pro... 0mm wide joint (not filled or backed). Flashing.. Indicative wall framing.. Indicative substrate wall. 0. Indicative concrete edge beam... Indicative internal ceiling and wall linings. Indicative box gutter.. Indicative structural steel.. Indicative roofing.. Indicative concealed grid ceiling suspension system. typical section detail : awning gutter - conceal fixed with M tape dwg no. parklex-00/

8 . mm thick panel fixed to top hat with mm wide x.mm thick M VHB continuous adhesive tape.. 0mm wide x mm deep x.mm bmt top hat channels fixed vertically, spaced at maximum 0mm centres mm long x mm deep spacer top hat or block fixed through sarking and backing sheet to plate, nogging or girt (provide masonry wall, spaced at 00mm maximum centres.. Impermeable non-reflective sarking lapped 0mm at joints, sealed at joints and and perimeter with continuous bead Sikaflex Pro... 0mm wide joint (not filled or backed).. Flashing.. Indicative roofing.. Indicative structural steel. 0. Indicative fascia framing.. Indicative concealed grid ceiling suspension system.. Indicative roof purlin. 0 typical section detail : awning fascia - conceal fixed with M tape dwg no. parklex-00/

9 typical plan detail :.. mm thick panel fixed to top hat with mm wide x.mm thick M VHB continuous adhesive tape. 0mm wide x mm deep x.mm bmt top hat channels fixed vertically, spaced at maximum 0mm centres mm long x mm deep spacer top masonry wall, at 00mm maximum centres.. Impermeable non-reflective sarking lapped 0mm at joints, sealed at joints and perimeter with continuous bead of Sikaflex Pro. typical plan detail :.. Hardi-flex fibre cement sheet (to framed up walls). 0mm wide joint (not filled or backed).. Indicative wall framing/ substrate. typical plan detail : - conceal fixed with M tape dwg no. parklex-00/

FACE CFP - HORIZONTAL PANELS - OPTION 'B'

FACE CFP - HORIZONTAL PANELS - OPTION 'B' - Vertical Transitions 12F - H10.3 VHB TAPE 5.000" 127.0mm 5" FORMED TRANSITION STRIP w/ FLAT FACE CFP - - OPTION 'B' H10.3 CONCEALED FASTENED Panel Index 12F - H0 BASE DETAILS JOINT DETAIL PARAPET ROOF

More information

12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS

12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS CONCEALED FASTENED PANELS CFP-12 PANEL INDEX 12 - V0 BASE DETAILS HORIZONTAL JOINT DETAIL PARAPET ROOF DETAIL INSIDE CORNER DETAIL OUTSIDE CORNER DETAIL SOFFIT DETAIL WINDOW JAMB DETAIL WINDOW HEAD DETAIL

More information

Timber Separating Walls 3.3.3

Timber Separating Walls 3.3.3 3.3.3 Timber Separating Walls CONSTRUCTION DETAILS 246 INTRODUCTION Timber double stud walls are commonly used as separating walls, providing fire safety and acoustic separation between dwellings. This

More information

FIRE RATING MATERIAL FIXING NOTES

FIRE RATING MATERIAL FIXING NOTES FIRE RATING MATERIAL FIXING NOTES FIRE RATING MATERIAL FIXING NOTES... 1 External Wall Systems... 2 Non load bearing steel stud walls... 3 LOAD-BEARING STEEL STUD WALLS... 3 NON LOAD-BEARING TIMBER STUD

More information

NU-WALL EXTRUDED ALUMINIUM CLADDING. Installation Specifications Vertical orientation (over cavity)

NU-WALL EXTRUDED ALUMINIUM CLADDING. Installation Specifications Vertical orientation (over cavity) September 2014 NU-WALL EXTRUDED ALUMINIUM CLADDING Installation Specifications Vertical orientation (over cavity) 1. NW-V001C; Cavity batten layout 2. NW-V002C; Battening options 3. NW-V002C; Battening

More information

MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA

MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA Existing Yard Security Light Proposed Rooftop Mechanical Screening (Slate Gray) Proposed 3 x4 x 4 x4 Windows Metal Awning Existing Doors Metal Siding(Slate Gray) Trim (Matte Black) 14 14 Proposed Addition

More information

The better way to build TM. Installation Manual NAILBASE PANELS

The better way to build TM. Installation Manual NAILBASE PANELS The better way to build TM Installation Manual PANELS November 2018 SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................

More information

BENCHMARK Evolution Axis

BENCHMARK Evolution Axis Sheet List EVO VT 00 B DIRECTION OF PREVAILING WIND VERTICAL PANEL JOINT & FASTENER LOCATIONS DIRECTION OF LAY FACTORY APPLIED WEATHER SEAL CONCEALED PANEL FIXING NOTE: FASTENER NUMBERS DEPEND ON THE ACTUAL

More information

rondo accessories CONTENTS:

rondo accessories CONTENTS: rondo accessories SUMMARY Rondo has a range of accessories to complement our steel wall and ceiling systems, which includes Top Hats, Reveal Beads and Angles, as well as a rod bending tool for suspended

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 6 7 8 10 OUTSIDE CORNER 19 20 4 5 11 21 22 15 16 13 12 OPENING 14 SOFFIT 18 END WALL 17 INSIDE CORNER 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CCV-01 CCV-02 CCV-03 CCV-04 CCV-05 CCV-06 CCV-07 CCV-08

More information

WALL CEILING FACADE ACCESSORIES ACCESS PANELS CONTACT CLICK TO START

WALL CEILING FACADE ACCESSORIES ACCESS PANELS CONTACT CLICK TO START CLICK TO START About Knauf Metal Knauf Metal is part of the Knauf Group, leaders in lightweight construction materials, and a major supplier and manufacturer of metal building systems to the Australian

More information

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185 Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185 GENERAL REQUIREMENTS 185 FRAMING 185 PLASTERBOARD LAYOUT 189 PLASTERBOARD FIXING 190 EXTERIOR

More information

ENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL

ENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL ENVELOPE 2000 ROUT & RETURN (RR) SYSTEM The Ultimate In Performance In A Wet-Sealed System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties

More information

WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.

WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED. WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED. Build walls and ceilings with a strong base, sturdy reinforcements and much more with Phillips extensive line of high quality products. As a single source

More information

Typical detail: New roof with breathable underlay

Typical detail: New roof with breathable underlay New roof with breathable underlay 6. WALLTITE CL00 insulation to achieve target U-value. Vapour control layer. Plasterboard and skim. Unventilated air space 5. WALLTITE returned to insulated cavity stop

More information

Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier Typical Details (THIS PAGE INTENTIONALLY LEFT BLANK Pebbletex Wall System Class PB Exterior Insulation

More information

Technical & Installation Manual

Technical & Installation Manual Technical & Installation Manual Product Description and Construction Details March 2016 V2.1 Office: 0800 484 552 or 03-313 3672 E-Mail: info@villagestone.co.nz Web Site: www.villagestonechristchurch.co.nz

More information

SOLITEX EXTASANA ADHERO SELF-ADHESIVE UNDERLAY. Product. Scope. Appraisal No. 989 [2017] Appraisal No. 989 (2017) BRANZ Appraisals

SOLITEX EXTASANA ADHERO SELF-ADHESIVE UNDERLAY. Product. Scope. Appraisal No. 989 [2017] Appraisal No. 989 (2017) BRANZ Appraisals SOLITEX EXTASANA ADHERO SELF-ADHESIVE UNDERLAY BRANZ Appraisals Technical Assessments of products for building and construction. Product 1.1 is a self-adhesive, synthetic underlay for use over rigid wall

More information

GAF EnergyGuard Polyiso Wall Sheathing

GAF EnergyGuard Polyiso Wall Sheathing From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include:

More information

WeatherSmart Air Barrier Installation Guide

WeatherSmart Air Barrier Installation Guide WeatherSmart Air Barrier Installation Guide 1 The intent of this document is to provide a guide for the installation of WeatherSmart as both a Weather Resistive Barrier (W.R.B.) and an Air Barrier Material

More information

Bituminous Roofing Underlay & Valley Guard

Bituminous Roofing Underlay & Valley Guard CONTENTS SUMMARY OF FEATURES... 2 TECHNICAL INFORMATION... 2 Product Description... 2 Applications... 2 Product Information... 2 Handling & Storage... 5 Technical Data... 5 Installation Information...

More information

ENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL

ENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL ENVELOPE 2000 RAINSCREEN (RS) SYSTEM The Ultimate In Performance In A Dry-Joint System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties

More information

STOPOREN FACADE SYSTEM PARAPET/METAL FLASHING DETAIL

STOPOREN FACADE SYSTEM PARAPET/METAL FLASHING DETAIL PROVIDE SEPARATION (ROOF UNDERLAY) UNDER METAL CAPPING AND 9mm MIN.H3 PLY - PACKED TO A FALL 5 PRE FINISHED METAL CAPPING TO PARAPET WITH 5 MIN.FALL Z Z REFER TABLE 7 - E2/AS1 CARRY MESH/RENDER UP TO TOP

More information

LEEDS : LEEDS UNIVERSITY

LEEDS : LEEDS UNIVERSITY STAGE @ LEEDS : LEEDS UNIVERSITY Client : Leeds University Project Manager : Leeds University Structural Engineer : Bland and Swift Services Consultant : Preston Lee Chambers Contractor : Brenville Construction

More information

Installation Guide. HardieBreak Thermal Strip COMPONENTS

Installation Guide. HardieBreak Thermal Strip COMPONENTS Installation Guide HardieBreak Thermal Strip COMPONENTS Australia April 2018 Make sure your information is up to date. When specifying or installing James Hardie products, ensure you have the current installation

More information

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation.

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation. SECTION B Steel Frame Wall Systems. Contents. SUBJECT Steel Stud Selection Tables Introduction Design Considerations Installation Components PAGE B2 B4 B4 B6 B7 System Specifications Single Stud Staggered

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 8 4 5 6 9 16 10 15 11 SOFFIT 19 OUTSIDE CORNER 20 21 INSIDE CORNER 3 22 23 12 13 OPENING 14 END WALL 17 18 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY CSV-01 CSV-02 CSV-03 CSV-04 CSV-05 CSV-06 CSV-07 CSV-08

More information

Commercial Flashing Details

Commercial Flashing Details This technical note illustrates many of the most common flashing details for commercial buildings. The purpose for flashing is to direct moisture to the exterior and in so doing, prevent moisture from

More information

Concrete Soffit Direct Fix

Concrete Soffit Direct Fix Installation Guide Concrete Soffit Direct Fix Recommended Pattern insulation boards may be installed in any pattern. The recommended pattern is a square-set pattern, for simplest and quickest configuration

More information

Applies to lots: 6, 7, 10, 17, 18, 25, 26 Applies to lots: 1, 2, 3, 4, 8, 9, 12, 13, 14, 15, 16, 20, 21, 22, 23, 27, 28, 29, 30, 31

Applies to lots: 6, 7, 10, 17, 18, 25, 26 Applies to lots: 1, 2, 3, 4, 8, 9, 12, 13, 14, 15, 16, 20, 21, 22, 23, 27, 28, 29, 30, 31 TYPICAL FAÇADES SINGLE STOREY AND COMPACT FRONT-LOADED DWELLING REAR-LOADED DWELLING Applies to lots: 6, 7, 10, 17, 18, 25, 26 Applies to lots: 1, 2, 3, 4, 8, 9, 12, 13, 14, 15, 16, 20, 21, 22, 23, 27,

More information

Note:

Note: Email: sales@koolwall.com.au JANUARY 2009 ISSUE Note: When installing the koolwall panel system, please ensure you are using a copy of the most recently published edition of the installation manual. If

More information

Introduction. Applications. Everest Facade Advantages

Introduction. Applications. Everest Facade Advantages EVEREST FACADE Everest Façade with Endura Everest Industries Limited Introduction The Everest Commercial Facade System provides a versatile and durable façade which is suitable for an extensive range of

More information

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications. SECTION D Wall Systems. Contents. SUBJECT Introduction Design Considerations Installation Components PAGE D2 D2 D4 D5 System Specifications Stud One Side Stud Both Sides Stud and Furring Channel Resilient

More information

Ameriplate. Rain Screen Wall System

Ameriplate. Rain Screen Wall System Ameriplate Rain Screen Wall System Efficiency and fascinating free-floating effects are hallmarks of Metalwërks Ameriplate wall systems. With Ameriplate, the cut edges of the face plate material are the

More information

Arcwall. Rain Screen Wall System

Arcwall. Rain Screen Wall System Rain Screen Wall System is an economical drained and back-ventilated rain screen system for both walls and soffits manufactured from formed aluminum or stainless plate. The system combines excellent performance

More information

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2 Contents BCA Codes 3 General 4 Fire Performances Thermal and Acoustic Insulation Wall Installation 4 Timber Frame Separation Walls 5 Steel Frame Separation Walls 6 External Fire Rated Walls 7 Floor Installation

More information

Bituminous Building Paper

Bituminous Building Paper CONTENTS SUMMARY OF FEATURES... 2 TECHNICAL INFORMATION... 2 Product Description... 2 Applications... 2 Product Information... 2 Handling & Storage... 5 Technical Data... 5 Installation... 5 Size Range

More information

STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details

STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C Stratum Guard I and II System Installation Details Stratum Guard I and II DETAIL Table of Contents NOTE SG.0.0.01 SG.0.0.02

More information

National Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ].

National Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ]. National Master Specification (NMS) Section 07 21 16 BLANKET INSULATION Publisher: Spex.ca Page 1 Approved: 2014-12-31 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section [ ]. 1.2 REFERENCES.1 CSA Group.1

More information

TYPICAL DETAILS MANUAL

TYPICAL DETAILS MANUAL TYPICAL ETAILS MANUAL ETAIL LIST AN ESCRIPTION ETAIL LIST RAWING NUMBER ETAIL NUMBER ETAIL ESCRIPTION ISION 01 ETAIL LIST 101 etail 101 Concrete Slab Edge etailing 102 etail 102 Concrete Set own etailing

More information

SEPARATING WALLS CLASS 1A

SEPARATING WALLS CLASS 1A TECHNICAL DATA SHEET ISSUED BY TIMBER QUEENSLAND SEPARATING WALLS CLASS 1A (DUPLEXES, TOWNHOUSES, BUILDINGS ROW HOUSES, TERRACE HOUSES) 33 RECOMMENDED PRACTICE // AUGUST 2014 Fire and sound are important

More information

excom (Expressed Panel Facade System) Primary top hat 160 x 35 x 1.0mm mm.

excom (Expressed Panel Facade System) Primary top hat 160 x 35 x 1.0mm mm. (Expressed Panel Facade System) is a versatile, glass fibre-reinforced recycled wood fibre and magnesium cement based cladding. Fabricated from a combination of recycled timber materials (50%), mineral

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 5 6 8 9 1 10 15 SOFFIT OUTSIDE CORNER 16 18 19 12 OPENING 11 END WALL INSIDE CORNER 17 1 7 5 6 ELEVATION FOR DETAIL REFERENCE ONLY IWV-01 IWV-02 IWV-0 IWV-0 IWV-05 IWV-06 IWV-07 IWV-08 IWV-09 IWV-10 INDEX

More information

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details Typical Details AcroWall-ES System Class PB Exterior Insulation and Finish System providing a primary moisture barrier 1. Typical AcroWall-ES System Application 2. Typical Aesthetic Reveal 3. Typical Window

More information

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING INSTALLING WATER-RESISTIVE BARRIERS & FLASHING IN A TWO-LAYER STUCCO APPLICATION Fortifiber Building Systems Group provides this guide to assist installers by demonstrating a two-layer installation of

More information

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board Perimeter Relief and Control Joints in Fire-Rated Gypsum Board In multi-family residential construction, involving fire-rated assemblies stress relief in the firerated assemblies is important, but often

More information

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board NOTES Senergy Platinum CI Stucco Typical details for an

More information

COMPANY NAME: Lump Sum. Lump Sum. Lintel 33. brick 500. L. ft. 200

COMPANY NAME: Lump Sum. Lump Sum. Lintel 33. brick 500. L. ft. 200 10. Schedule of Prices A. BUILDING #19 CARR ST. COMPANY NAME: Item No. GENERAL Description Estimated Quantity Price $ Total Bid $ A.1.1 Access and Protection Provide scaffolding and work stage at all elevations

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 6 7 8 10 26 19 20 14 15 22 SOFFIT OUTSIDE CORNER INSIDE CORNER 23 25 24 25 5 27 28 29 16 11 OPENING 17 18 END WALL 21 12 13 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CSH-01 CSH-02 CSH-03 CSH-04 CSH-05

More information

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights 1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights These 1 Exam Prep tabs are based on the 2012 Sheet Metal and Air Conditioning Contractors' National Association, Inc., seventh edition.

More information

Fire Resistant: Achieves FRL levels of 90/90/90 for load bearing walls.

Fire Resistant: Achieves FRL levels of 90/90/90 for load bearing walls. ( ) is a new and innovative system designed to provide high performance separating walls between units and apartments in low-rise residential and commercial projects. provides exceptional fire and acoustic

More information

robustdetails E-FC-7 Separating Floor Concrete Separating Floors Concrete E-FC-7

robustdetails E-FC-7 Separating Floor Concrete Separating Floors Concrete E-FC-7 DO Butt floor blocks tightly together Cover floor blocks with min 50mm concrete topping Ensure that concrete does not enter the cavity and bridge the two leaves of supporting wall blockwork - it is acceptable

More information

SURESILL WATER MANAGEMENT GUIDE

SURESILL WATER MANAGEMENT GUIDE THE SURE LEVEL OF PROTECTION SURESILL WATER MANAGEMENT GUIDE FOR WINDOWS AND DOORS *1 SLOPED SILL PAN ASSEMBLY Cut the channel plate ¼ smaller than the rough opening. Check the fit with end caps before

More information

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing EXTERIOR BASE DETAIL (FLUSH) EXTERIOR BASE DETAIL (OVERHANG) Base Trim with Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint Sealant Marriage Bead to Vertical Panel Joint Above and Below Z Flashing

More information

130mm CROATIA BOARD 180mm V-GROOVE

130mm CROATIA BOARD 180mm V-GROOVE Enjoy DecoClad s enduring beauty in the bush, by the beach or in full sun. Effortless to install and maintain, DecoClad is the ultimate in exterior cladding. Pairing aluminium s proven strength and durability

More information

COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE

COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INSTALLATION SEQUENCE TT 5-8 TT- 13 INSTALLATION SEQUENCE INSTALLATION SEQUENCE TT- 4 TT-10 TT-14 TT-12 TT- 3 TT-11 TT-10 TT- 9 TT-11 TT- 2 INDEX (TT- 0): SYSTEM

More information

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. SECTION 06110 WOOD FRAMING PART 1 GENERAL 1.1 SUMMARY A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But Not Supplied

More information

Specifications for Insulation Board wall and ceiling applications

Specifications for Insulation Board wall and ceiling applications Specifications for Insulation Board wall and ceiling applications Product Ref: Marmox Multiboard 600mm wide, 1250/2500mm long. 10, 12.5, 20, 30, 40, 50, 60mm thick. Also known as Marmox Board- Pro and

More information

Part E robustdetails. robustdetails. January 2018 Update Pack

Part E robustdetails. robustdetails. January 2018 Update Pack Part E Pack Dear Colleague, The first Update Pack of the year, and the first welcome from me as Chief Executive. Although new to the role, I have been with the company for nine years with responsibility

More information

Design Guide. HardieSmart Boundary Wall System (Class 1 & 10a) SYSTEMS FRL 60/60/60 FROM THE OUTSIDE. Rw R

Design Guide. HardieSmart Boundary Wall System (Class 1 & 10a) SYSTEMS FRL 60/60/60 FROM THE OUTSIDE. Rw R FRL 60/60/60 FROM THE OUTSIDE Rw 47-48 R 2.0-2.6 4.0-10 kn/m Design Guide HardieSmart Boundary Wall System (Class 1 & 10a) SYSTEMS Certificate CM20135 Australia October 2017 Make sure your information

More information

TECHNICAL DOCUMENT: SYSTEM INSTALLATION & CONSTRUCTION DETAILS

TECHNICAL DOCUMENT: SYSTEM INSTALLATION & CONSTRUCTION DETAILS MASTERWALL AUSTRALIA PTY LTD. 18-20 Cyber Loop, Dandenong South, Victoria, Australia EMAIL. sales@masterwall.com.au WEB. www.masterwall.com.au NATIONAL ENQUIRIES. (03) 9799 6565 FAX. (03) 8740 2180 TECHNICAL

More information

Design Manual Facade, riveted Panel fixed to T-Sections

Design Manual Facade, riveted Panel fixed to T-Sections Design Manual Facade, riveted Part Product changes in the sense of a technical progress are reserved. All advice recommendation and information is given to the best of our knowledge but without any obligation

More information

Residential Wall Panel Installation

Residential Wall Panel Installation Residential Wall Panel Installation Planning & System Parameters 1. Health & Safety Act 1992 The principle objects of the Health & Safety Employment Act 1992 (HSE Act) are to prevent harm to employees

More information

A Handbook of thermal bridging details incorporating aircrete blocks

A Handbook of thermal bridging details incorporating aircrete blocks A Handbook of thermal bridging details incorporating aircrete blocks Book 2 Thermal bridging solutions for external wall full fill cavity details Prepared for the Aircrete Products Association by the BBA

More information

Real Brick Cladding. Iso Klink Pur. Brick Panel System Catalogue

Real Brick Cladding. Iso Klink Pur. Brick Panel System Catalogue Iso Klink Pur Brick Panel System Catalogue 1 BRICK CLADDING PANEL SYSTEM Combination of high performance pur insulation and brick cladding, creating durable and aesthetic system which is quick and easy

More information

Siding and Soffit Installation Guidelines

Siding and Soffit Installation Guidelines Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field

More information

Aqua Coast Engineering

Aqua Coast Engineering Aqua Coast Engineering Ltd. P.O. Box 1367 Station A Delta, B.C. V4M 3Y8 Tel: (604)948-0958 Fax: 604)948-0959 September 1, 2011 Matthew Cheng File#:11145 Matthew Cheng Architect Inc. Fax: 604-731-3908 Unit

More information

The Passive Fire Protection Handbook

The Passive Fire Protection Handbook The Passive Fire Protection Handbook The UK s comprehensive guide to passive fire protection Chapter Ceilings, Floors and Roofs AUGUST 0 The Passive Fire Protection Handbook Contents Chapter : Introduction

More information

100 mm. 100 mm. 125 mm. 125 mm. 150 mm. 150 mm C003 C001 C269 C208 C055 C002. Tee Gee. Feather Edge. Shiplap. Open V. Open V.

100 mm. 100 mm. 125 mm. 125 mm. 150 mm. 150 mm C003 C001 C269 C208 C055 C002. Tee Gee. Feather Edge. Shiplap. Open V. Open V. 150 mm 100 mm 150 mm 100 mm 125 mm 125 mm C002 Shiplap C001 Shiplap C003 Open V C269 Open V C208 Feather Edge C055 Tee Gee C027 Starter trim C028 Wall starter trim C029 Drip starter trim C035 Drip/starter

More information

A. SYSTEM DETAILS A.1 Product Range

A. SYSTEM DETAILS A.1 Product Range 10. TYPICAL DRAWINGS & STANDARD DETAILS SCHEDULE OF STANDARD DETAILS. All drawings are NTS and dimensions are in mm Page No. A. SYSTEM DETAILS...10-1 A.1 Product Range...10-1 A.1.1 Residential Beam Profiles...10-1

More information

Installation Guide. ExoTec TM RAW (Pre-Finished) Facade Panel And Fixing System COMMERCIAL & RESIDENTIAL

Installation Guide. ExoTec TM RAW (Pre-Finished) Facade Panel And Fixing System COMMERCIAL & RESIDENTIAL Installation Guide ExoTec TM RAW (Pre-Finished) Facade Panel And Fixing System COMMERCIAL & RESIDENTIAL Certificate CM40221 Australia October 2018 Make sure your information is up to date. When specifying

More information

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope.

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope. SECTION 08 4519 - POLYCARBONATE WALL SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. Exterior System: The design, manufacture and installation of an aluminum and polycarbonate insulating translucent system.

More information

GCP APPLIED TECHNOLOGIES PERM-A-BARRIER VPL 50

GCP APPLIED TECHNOLOGIES PERM-A-BARRIER VPL 50 MASONRY ANCHOR DETAILING:. GASKETED STANDOFF ANCHOR 0 MIN.. SURFACE MOUNTED ANCHOR " MIN. 7 9. LADDER STYLE ANCHOR.. MASONRY ANCHOR DETAILING. S00, -INCH TROWELED BEAD. MORTAR COLLECTION MESH. PERM-A-BARRIER

More information

AA Series 150mm Frame Doors (3 & 6 Panel Stacker Doors Illustrated)

AA Series 150mm Frame Doors (3 & 6 Panel Stacker Doors Illustrated) (3 & 6 Panel Stacker Doors Illustrated) SINGLE LEAF CLADDING / CORRUGATED STEEL (3 & 6 Panel Stacker Doors Illustrated) SINGLE LEAF CLADDING / FOAM BOARD (3 & 6 Panel Stacker Doors Illustrated) BRICK VENEER

More information

A Handbook of thermal bridging details incorporating aircrete blocks

A Handbook of thermal bridging details incorporating aircrete blocks A Handbook of thermal bridging details incorporating aircrete blocks Book 1 Thermal bridging solutions for external wall partial fill cavity details and full fill party wall details Prepared for the Aircrete

More information

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs November 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements....................................

More information

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer... SECTION DIRECTORY General Information Introduction... V250-ID-886 Installation Accessories and Applications... V250-ID-886 Typical Sealant Placement Details... V250-ID-887 Fin Installation Details Wood

More information

Wet Areas Using Plasterboard

Wet Areas Using Plasterboard INSTALLATION 168 DEFINITIONS 168 WET AREA REQUIREMENTS 168 WATERPROOFING REQUIREMENTS BY AREA 169 GENERAL REQUIREMENTS 171 FRAMING 171 PLASTERBOARD LAYOUT 171 PLASTERBOARD FIXING 171 CONSTRUCTION DETAILS

More information

Illawarra Flame G-000 UNIVERSITY OF WOLLONGONG SOLAR DECATHLON 2013 COVER. Team Name: Address: Contact:

Illawarra Flame G-000 UNIVERSITY OF WOLLONGONG SOLAR DECATHLON 2013 COVER. Team Name: Address: Contact: Illawarra Flame SOLAR DECATHLON 203 Solar Decathlon China 203 P Preliminary Issue 3.8.2 C2 Schematic Design Re-Issue 30..3 C3 Final Submission 5.3.3 C4 As Built Issue 03.6.3 @ A3 COVER G-000 A-600 2 A-600

More information

SECTION GYPSUM BOARD ASSEMBLIES

SECTION GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 09260 - A. Metal stud wall framing. Denoted on drawings as "metal studs". B. Metal channel ceiling framing. C. Acoustic insulation and sealant. D. Cementitious

More information

SPECIFICATION: CLASSIC PROGRESSIVE MOVABLE WALL SYSTEM DEMOUNTABLE STEEL STUD AND GYPSUM BOARD PARTITIONS

SPECIFICATION: CLASSIC PROGRESSIVE MOVABLE WALL SYSTEM DEMOUNTABLE STEEL STUD AND GYPSUM BOARD PARTITIONS SPECIFICATION: CLASSIC PROGRESSIVE MOVABLE WALL SYSTEM DEMOUNTABLE STEEL STUD AND GYPSUM BOARD PARTITIONS PART 1 GENERAL 1.1 RELATED WORK SPECIFIED IN OTHER SECTIONS 1.2 DESCRIPTION OF SYSTEM A. GENERAL:

More information

Ameriplate. Rain Screen Wall System

Ameriplate. Rain Screen Wall System Ameriplate Rain Screen Wall System Efficiency and fascinating free-floating effects are hallmarks of Metalwërks Ameriplate wall systems. With Ameriplate, the cut edges of the face plate material are the

More information

DURAGRID TM FACADE SYSTEMS

DURAGRID TM FACADE SYSTEMS NOVEMBER 2016 LIGHT COMMERCIAL & RESIDENTIAL STEEL FRAMED BUILDINGS DURAGRID TM FACADE SYSTEMS AUSTRALIAN OWNED & MANUFACTURED WWW.BGCINNOVADESIGN.COM.AU NOVEMBER 2016 INNOVA BGC S STUNNING RANGE OF FACADE,

More information

SECTION NON-STRUCTURAL METAL FRAMING

SECTION NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 22 16 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information

Primary Concerns and Defects

Primary Concerns and Defects Primary Concerns and Defects Primary Concerns and Defects: Home Inspector Observations: Where to Look. What to Look For. What Observed condition may mean. Primary Concerns The points to be inspected per

More information

Light-Metal Roof Edge, Raised

Light-Metal Roof Edge, Raised NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED

More information

Siding and Soffit Installation Guidelines

Siding and Soffit Installation Guidelines Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field

More information

AS Interpretation of External Waterproofing as it applies to Melbourne, Class 1 buildings

AS Interpretation of External Waterproofing as it applies to Melbourne, Class 1 buildings AS4654.2 Interpretation of External Waterproofing as it applies to Melbourne, Class 1 buildings Climate Zone: 6 Wind Class: N1 Membrane Types: Liquid Applied Class II and Class III as defined and tested

More information

PARKSIDE QUARRIES Ltd

PARKSIDE QUARRIES Ltd 5mm min. vent space soffit lining optional 20x20 bead optional cavity vents formed to top course of veneer 2 5 Wall ties screw fixed over underlay to structural frame and positioned within 300mm or two

More information

AA Series 90mm Frame Windows (Operated Casement Window Illustrated)

AA Series 90mm Frame Windows (Operated Casement Window Illustrated) (Operated Casement Window Illustrated) SINGLE LEAF CLADDING / CORRUGATED STEEL (Counter Balanced Double-Hung Window Illustrated) SINGLE LEAF CLADDING / FOAM BOARD (Horizontal Sliding Window Illustrated)

More information

Detail Booklet StoTherm ci XPS

Detail Booklet StoTherm ci XPS Detail Booklet Series 53sxx Steel Frame Construction February 2017 professional, general contractor or builder They should be installed in accordance with those specifications and Sto s instructions Sto

More information

GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS

GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS CONTENTS Introduction 2 Applications 3 Advantages 3 Components 3 6 Design Considerations 7 8 System Features 10 Typical installation Sequence

More information

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

A Closer Look Inspection Service 2015 IECC Residential DFW area handout 103.2 Information required on construction documents 1. Designation of the Thermal Building Envelope on the plans 2. Insulation Material and their R Value 3. Fenestration U and SHGC values 4. Area weighted

More information

CEMINTEL FIBRE CEMENT SYSTEMs RESIDENTIAL EXPRESSWALL. fc936 oct external cladding systems

CEMINTEL FIBRE CEMENT SYSTEMs RESIDENTIAL EXPRESSWALL. fc936 oct external cladding systems CEMINTEL FIBRE CEMENT SYSTEMs RESIDENTIAL EXPRESSWALL external cladding systems fc936 oct 2008 Contents Contents 2 Description 2 Applications 2 Advantages 3 Components 4 6 Design Considerations 7 10 Architectural

More information