FORM -1 CAPITAL CITY COMMERCIAL PROJECT. Plot No. 2B, Sector 94, Noida, District: Gautam Budh Nagar, Uttar Pradesh

Size: px
Start display at page:

Download "FORM -1 CAPITAL CITY COMMERCIAL PROJECT. Plot No. 2B, Sector 94, Noida, District: Gautam Budh Nagar, Uttar Pradesh"

Transcription

1

2

3 Sector - 94, ida, FORM-1 FORM -1 CAPITAL CITY COMMERCIAL PROJECT at Plot. 2B, Sector 94, ida, District: Gautam Budh Nagar, Uttar Pradesh M/s. BPTP INTERNATIONAL TRADE CENTRE LIMITED M-11, Middle Circle, Connaught Place, New Delhi BPTP International Trade Center Ltd. 1

4 Sector - 94, ida, FORM-1 (i) Basic Information APPENDIX I (See paragraph 6) FORM 1 S.. Item Details 1. Name of the project/s Commercial Project at Plot. 2B, Sector 94, ida, Uttar Pradesh. 2. S.. in the schedule Category 8 (b) 3. Proposed capacity/area/length/tonnage to be handled/command area/lease area/number of well to be drilled Plot Area: Sqm. or Acs. Built-up Area: Sqm. Ground Coverage: 14, Sqm. 4. New/Expansion/Modernization New 5. Existing Capacity/Area etc. Plot Area: Sqm. or Acs. Built-up Area: Sqm. Ground Coverage: 14, Sqm. 6. Category of Project i.e. A or B Category B1 7. Does it attract the general condition? If yes, please specify. 8. Does it attract the specific condition? If yes, please specify. 9. Location Commercial Project in Sector 94, ida, Uttar Pradesh Plot/Survey/Khasra. Plot. 2B Village -- Tehsil Gautam Budh Nagar District Gautam Budh Nagar State Uttar Pradesh 10. Nearest railway station/airport along with distance in kms. 11. Nearest Town, city, District Headquarters along with distance in kms. 12. Village Panchayat, Zilla Parishad, Municipal Corporation, Local body (complete postal addresses with telephone nos. to be given) Haz. Nizamuddin Railway station located at approx. 10 Km via road IGI Airport located at approx. 28 Km via road Project falls itself in District Headquarter ida New Okhla Industrial Development Authority (ida) Administrative Complex Sector 6, ida District Gautam Budh Nagar, U. P 13. Name of the applicant Shri Rajeev Gupta 14. Registered Address 15. Address for correspondence: Name Designation (Owner/Partner/CEO) Cell Phone: FAX: C/o BPTP International Trade Centre Ltd BPTP International Trade Center Ltd. 2

5 Sector - 94, ida, FORM-1 S.. (ii) Address M-11, Middle Circle Connaught Circus New Delhi Pin Code rajeev.gupta@bptp.com Telephone Fax Details of Alternative Sites examined, if any. Location of these sites should be shown on a topo sheet. 17. Interlinked Projects N.A 18. Whether separate application of interlinked project has been submitted? N.A 19. If yes, date of submission N.A 20. If no, reason N.A 21. Whether the proposal involves approval/clearance under: if yes, details of the same and their status to be given. (a) The Forest (Conservation) Act, 1980? (b) The Wildlife (Protection) Act, 1972? (c) The C.R.Z. tification, 1991? 22. Whether there is any Government Order/Policy relevant/relating to the site? The alternatives sites examination not applicable since the project activity is being developed as per sanction plan approved by NOIDA and also land allocated by the authority for development of project scheme as per NOIDA Master Plan 2021 N.A N.A 23. Forest land involved (hectares) Forest Land Involved 24. Whether there is any litigation pending against the project and/or land in which the project is propose to be set up? (a) Name of the Court (b) Case. (c) Orders/directions of the Court, if any and its relevance with the proposed project. NO since Eco-sensitive zone (ESZ) already marked around Okhal Bird sanctuary (OBS) and project not come under the declared buffer area around OBS Activity 1. Construction, operation or decommissioning of the Project involving actions, which will cause physical changes in the locality (topography, land use, changes in water bodies, etc. Information/Checklist confirmation Yes/ Details thereof (with approximate quantities /rates, wherever possible) with source of information data BPTP International Trade Center Ltd. 3

6 Sector - 94, ida, FORM Permanent or temporary change in land use, land cover or topography including increase in intensity of land use (with respect to local land use plan) 1.2 Clearance of existing land, vegetation and buildings? BPTP International Trade Center Ltd. 4 Yes The land is allocated from NOIDA for setting up Commercial project and building plan of revised area also approved from the authority which are in accordance with the land usage defined in the NOIDA Master Plan 2021 t required since site developed as per approved building plan 1.3 Creation of new land uses? The land is allocated from NOIDA for setting up Commercial project as per defined land use in the NOIDA master plan Pre-construction investigations e.g. bore houses, soil testing? Yes Soil testing has already been done, which shows that the soil consistency is strong enough with load bearing capacity. 1.5 Construction works? Yes Building construction and lying of services such as water supply, storm water drainage, sewerage and lighting and green. 1.6 Demolition works? demolition work. 1.7 Temporary sites used for construction works or housing of construction workers? 1.8 Above ground buildings, structures or earthworks including linear structures, cut and fill or excavations 1.9 Underground works including mining or tunneling?, temporary residential facilities for labours provided within project premises as labours during construction engaged and hired from nearby area Nil underground works required except construction of basements Reclamation works? t Applicable, as the proposed project is Commercial project Dredging? t Applicable, as the proposed project is Building project Offshore structures? t Applicable Production and manufacturing processes? 1.14 Facilities for storage of goods or materials? 1.15 Facilities for treatment or disposal of solid waste or liquid effluents? Yes This is a Commercial project, so there will be no production and manufacturing. During construction phase, temporary sheds for storage of cement and other material has been provided within the project premises. The solid waste generated from project during operational phase will be temporarily stored for 48 hours and suitably segregated in to mainly organic (wet waste) and recyclable (dry waste) and to be managed as per Solid waste management Rules

7 Sector - 94, ida, FORM Facilities for long term housing of operational workers? 1.17 New road, rail or sea traffic during construction or operation? 1.18 New road, rail, air waterborne or other transport infrastructure including new or altered routes and stations, ports, airports etc? 1.19 Closure or diversion of existing transport routes or infrastructure leading to changes in traffic movements? 1.20 New or diverted transmission lines or pipelines? 1.21 Impoundment, damming, culverting, realignment or other changes to the hydrology of watercourses or aquifers? 2016 dated 08/04/2016 as amended up to date. STP of adequate capacity to be installed for treatment of waste water generated during the operational phase of project and Sludge generated from STP shall be converted into an odorless soil conditioner and used as manure for gardening purpose. All wastewater outlet pipes form toilets and kitchen, will be connected to Sewage Treatment Plant for the final treatment. Treated water to be re-used for flushing, make up water for HVAC cooling and horticulture There are no such facilities for long term housing of operational workers, as all operational workers will come from nearby areas. t applicable new alternative transport infrastructure is envisaged except Grade separated entry / exit are proposed from expressway as well as kalindi Kunj road. Grade separated movement is proposed at entry/exit beyond the existing carriageway. There will not be any change in existing transport route or existing traffic movement There will not be any new or diverted transmission lines or pipelines around the project. t Applicable 1.22 Stream crossings? t Applicable 1.23 Abstraction or transfers of water form ground or surface waters? 1.24 Changes in water bodies or the land surface affecting drainage or runoff? 1.25 Transport of personnel or materials for construction, operation or decommissioning? Water requirement will be met from municipal supply (ida Jal Board). Dewatering for basement, if required. Nil Transport of personnel/material during the construction & operation envisaged. During operation, adequate parking space to be provided for vehicles. BPTP International Trade Center Ltd. 5

8 Sector - 94, ida, FORM Long-term dismantling or decommissioning or restoration works? 1.27 Ongoing activity during decommissioning which could have an impact on the environment? 1.28 Influx of people to an area in either temporarily or permanently? t Applicable t Applicable 1.29 Introduction of alien species? t Applicable 1.30 Loss of native species or genetic diversity? Yes The influx of people will be short term only during construction phase and after completion of project, floating population will come as it is a commercial building Any other actions? Nil Nil S.. t Applicable 2. Use of Natural resources for construction or operation of the Project (such as land, water, materials or energy, especially any resources which are non-renewable or in short supply): Information/checklist confirmation 2.1 Land especially undeveloped or agricultural land (ha) 2.2 Water (expected source & competing users) unit: KLD Yes/ Yes 2.3 Minerals (MT) Yes t Applicable 2.4 Construction material stone, aggregates, sand / soil (expected source MT) Yes 2.5 Forests and timber (source MT) Nil 2.6 Energy including electric town and fuels (source, competing users) Unit: fuel (MT), energy (MW) Yes Details thereof (with approximate quantities /rates, wherever possible) with source of information data The land allocated by the ida Authority for setting up the commercial building complex. The total water requirement for the proposed project will be 1003 KLD which will be met from Municipal water supply. Construction material will be used in a small quantity, as finishing work is under progress. Electrical Energy requirement would be around 19.2 MVA and Source will be UPPCL. Presently DG sets of 2000 KVA and 1000 KVA proposed to meet the power requirement during power failure and Fuel shall be HSD (ultra-low Sulphur diesel). The power back up will be 100%. DG set will be the main source of noise pollution. The DG sets shall be used only in case of power failure and will be provide with acoustic enclosures. BPTP International Trade Center Ltd. 6

9 Sector - 94, ida, FORM Any other natural resources (use appropriate standard units) S.. t Applicable 3. Use, storage, transport, handling or production of substances or materials, which could be harmful to human health or the environment or raise concerns about actual or perceived risks to human health. Information/Checklist confirmation 3.1 Use of substances or materials, which are hazardous (as per MSIHC rules) to human health or the environment (flora, fauna, and water supplies) 3.2 Changes in occurrence of disease or affect disease vectors (e.g. insect or water borne diseases) 3.3 Affect the welfare of people e.g. by changing living conditions? 3.4 Vulnerable groups of people who could be affected by the project e.g. hospital patients, children, the elderly etc., Yes/ 3.5 Any other causes Nil Nil S.. Details thereof (with approximate quantities/rates, wherever possible) with source of information data t Applicable effect envisaged effect envisaged effect envisaged 4. Production of solid wastes during construction or operation or decommissioning (MT/month) Information/Checklist confirmation Yes/ Details thereof (with approximate quantities/rates, wherever possible) with source of information data 4.1 Spoil, overburden or mine wastes t Applicable, as it is a building project. 4.2 Municipal waste (domestic and or commercial wastes) 4.3 Hazardous wastes (as per Hazardous Waste Management Rules) Yes Yes The estimated quantity of the solid waste generated will be approx kg/day as per CPHEEO manual defined for commercial and residential refuse The solid waste so generated shall be first segregated as in to organic and recyclable waste and managed as Solid waste management Rules 2016 dated 08/04/2016 as amended up to date. Only used lube oil (category 5.1) from DG set operated during power failure as per Hazardous and Other Wastes (Management and Transboundary Movement) Rules, 2016 dated 04/04/ Other industrial process wastes t Applicable, as it is a Commercial project. BPTP International Trade Center Ltd. 7

10 Sector - 94, ida, FORM Surplus product t Applicable, as it is a Commercial project. 4.6 Sewage sludge or other sludge from effluent treatment Yes Sludge generated from STP will be converted into an odorless Soil Conditioner and used as manure for gardening purpose. The Total untreated water generation will be 791 KLD (approx.), which will be treated in STP. 4.7 Construction or demolition wastes Yes There will not be any generation of demolition waste as per Construction and Demolition Waste Management Rules, 2016 dated 29/03/2016 since development executed/to be executed on vacant land and excavated soil used in the backfilling of site development and landscape area development. 4.8 Redundant machinery or equipment Nil 4.9 Contaminated soils or other materials Nil 4.10 Agricultural wastes Nil 4.11 Other solid wastes t applicable S.. 5. Release of pollutants or any hazardous, toxic or noxious substances to air (Kg/hr) Information/Checklist confirmation 5.1 Emissions from combustion of fossil fuels from stationary or mobile sources 5.2 Emissions from production processes 5.3 Emissions from materials handling including storage or transport Yes/ Yes BPTP International Trade Center Ltd. 8 Details thereof (with approximate quantities/rates, wherever possible) with source of information data The emission of SO 2 & SPM may be due to use of diesel in D.G. set. The emissions will be very limited since HSD (Ultra-low Sulphur diesel) fuel to be procured and used in DG only during power failure. Better maintenance and installation of proper pollution control equipment and adequate stack height as per CPCB guidelines will help to reduce such emissions. Proper acoustic enclosure & stack height. t Applicable The fugitive emission will be there due to the transportation activity and vehicular movements. The dust particles due to balance construction activities give rise to increase in PM2.5 and PM10 concentration of ambient air. Proper mitigating measures as per MoEF&CC guidelines 2010 are being followed and to be continued in future as well in compliance of Hon ble. NGT direction dated 17/04/2015.

11 Sector - 94, ida, FORM Emissions from construction activities including plant and equipment 5.5 Dust or odours from handling of materials including construction materials, sewage and waste 5.6 Emissions from incineration of waste 5.7 Emissions from burning of waste in open air (e.g. slash materials, construction debris) Yes Yes 5.8 Emissions from any other sources Nil Fugitive dusts from various activities of construction are expected, which are temporary in nature and to be controlled by regular water sprinkling. Dust generation is related only during earth work and it is temporary in nature and activities completed. There will be no source of odour t Applicable t Applicable 6. Generation of ise and Vibration, and Emissions of Light and Heat: S.. Information/Checklist confirmation 6.1 From operation of equipment e.g. engines, ventilation plant, crushers Yes/ Yes 6.2 From industrial or similar processes t Applicable Details thereof (with approximate quantities/rates, wherever possible) with source of information data with source of information data Slight noise generation will occur due to operation of D.G. set but that will occur only in case of power failure and hence DG are equipped with acoustic enclosure. 6.3 From construction or demolition demolition work is involved in the setting up of proposed Commercial colony and slight noise generation will occur due to construction work and all suitable arrangements shall be done to minimize it. 6.4 From blasting or piling t Applicable 6.5 From construction or operational traffic Yes 6.6 From lighting or cooling systems t Applicable 6.7 From any other sources t Applicable The noise generation will be very low as limited quantity of construction materials transported. Some noise generation will occur due to movement of traffic. During traffic movement in operation phase, it is likely to be in the range of db (A) only as it is an intermittent / slow process. 7. Risks of contamination of land or water from releases of pollutants into the ground or into sewers, surface waters, groundwater, coastal waters or the sea: S. Information/Checklist Yes/ Details thereof (with approximate quantities/rates, BPTP International Trade Center Ltd. 9

12 Sector - 94, ida, FORM-1. confirmation wherever possible) with source of information data 7.1 From handling, storage, use or spillage of hazardous materials 7.2 From discharge of sewage or other effluents to water or the land (expected mode and place of discharge) 7.3 By deposition of pollutants emitted to air into the land or into water Yes t Applicable The total untreated water generation will be 791 KLD which will be treated in proposed STP of 955 KLD. All waste water outlet pipes form toilets, pantries etc. will be connected to sewer lines leading to Sewage Treatment Plant for the final treatment. Sludge generated from STP will be converted into an odorless soil conditioner and used as manure for gardening purpose. t Applicable 7.4 From any other sources t Applicable 7.5 Is there a risk of long term build up of pollutants in the environment from these sources? t Applicable S.. 8. Risk of accidents during construction or operation of the Project, which could affect human health or the environment Information/Checklist confirmation 8.1 From explosions, spillages, fires etc from storage, handling, use or production of hazardous substances Yes/ 8.2 From any other causes t Applicable 8.3 Could the project be affected by natural disasters causing environmental damage (e.g. Floods, earthquakes, landslides, cloudburst etc)? BPTP International Trade Center Ltd. 10 Details thereof (with approximate quantities/rates, wherever possible) with source of information data Construction/Operation of Commercial Project shall follow all applicable guidelines imposed under part 04 (Fire and Life safety) as per National Building Code of India Fire safety measures include Fire extinguishers, Water tanks, Yard hydrants, hose reels, automatic detection system, illuminated Exit site, basement sprinkler system and compartmentalization etc. cases are reported so far. The site is selected carefully keeping in view all the factors to avoid any environmental damage due to natural disasters. 9. Factors which should be considered (such as consequential development) which could lead to environmental effects or the potential for cumulative impacts with other existing or planned activities in the locality S. Information/Checklist confirmation Yes/ Details thereof (with approximate quantities/rates, wherever possible) with

13 Sector - 94, ida, FORM-1. source of information data 9.1 Lead to development of supporting. Utilities, ancillary development or development stimulated by the project which could have impact on the environment e.g.: Supporting infrastructure (roads, power supply, waste or waste water treatment, etc.) Housing development Extractive industries Supply industries Other 9.2 Lead to after-use of the site, which could have an impact on the environment Yes The development of the commercial project will eventually give rise to economic status to the area. The area will have very good supporting social as well as physical infrastructure. The existing infrastructure on the adjoining sectors is also very good. t Applicable 9.3 Set a precedent for later developments Yes A better after use scenario, which is likely to increase aesthetic beauty of area & greenery, would set precedence for subsequent entrepreneurs who venture such projects. 9.4 Have cumulative effects due to proximity to other existing or planned projects with similar effects The proposed project is a Commercial colony project. A better-planned and executed project has to yield a better result individually. (iii) Environmental Sensitivity S.. Areas Name/ Identity 1 Areas protected under international conventions, national or local legislation for their ecological, landscape, cultural or other related value 2 Areas which are important or sensitive for ecological reasons - Wetlands, watercourses or other water bodies, coastal zone, biospheres, mountains, forests 3 Areas used by protected, important or sensitive species of flora or fauna for breeding, nesting, foraging, resting, over wintering, migration Yamuna River Aerial distance (within 15 km.) Proposed project location boundary t applicable About 01 km from project site BPTP International Trade Center Ltd. 11

14 Sector - 94, ida, FORM-1 4 Inland, coastal, marine or underground waters 5 State, National boundaries Delhi state boundary 6 Routes or facilities used by the public Akshardham for access to recreation or other Temple tourist, pilgrim areas 7 Defence installations 8 Densely populated or built-up area 9 Areas occupied by sensitive manmade land uses (hospitals, schools, places of worship, community facilities) 10 Areas containing important, high quality or scarce resources (Ground water resources, surface resources, forestry, agriculture, fisheries, tourism, minerals) 11 Areas already subjected to pollution or environmental damage. (Those where existing legal environmental standards are exceeded) 12 Areas susceptible to natural hazard which could cause the project to present Environmental problems (Earthquakes, subsidence, landslides, erosion, flooding or extreme or adverse climatic conditions) ida Yes t Applicable t Applicable t Applicable About 02 km from project site About 07 km from project site (IV). Proposed Terms of Reference for EIA studies-exemption regarding The site is located in sector 94 ida and surrounded by moderately populated built up area. There are number of major hospitals within the 15 km radius of the project site. There are numerous places of worship and community within the project influenced area. There is no any high quality or scarce resources. Environmental Damage Reported from the area so far. All parameters of Air, Water, and ise etc. will be maintained within permissible limits with proper mitigation measures. The area falls in zone IV, according to the Indian standard seismic Zoning map. Suitable seismic coefficient in horizontal and vertical directions respectively, has to be adopted while designing the structures. There are no possibilities of the proposed project site getting flooded as per records available. Instead of Comprehensive Terms of reference (ToR) under category 8 (b) only applicable Terms of reference (tor) may please be issued by the expert committee since it is a case wherein Environmental clearance already granted from SEIAA, UP vide Ref. 887/SEAC/277/2008/TA (J)/ dated 01 June 2009 and after grant of due CTE (NOC) from UPPCB the construction activity initiated and company has raised the construction of about SQM against already approved Built-up area SQM as per earlier issued Environmental clearance. BPTP International Trade Center Ltd. 12

15 Sector - 94, ida, FORM-1 The key details of project are as follows:- S. Particulars Area in Sq.Mt. 1. Total Plot Area (100 %) 57, Ground Coverage (24.87 %) 14, Proposed FAR Area 1,29, Total Built-up Area 2,73, Green Area (43.88 %) 25, Open Area 43, Total Paved Area (31.25%) 17, Parking Required 2931 ECS 9. Parking Provided 3136 ECS 10. Total Population 30,509 Staff 13,084 Visitors 17,425 I hereby given undertaking that the data and information given in the application for modernization/revision application and enclosures are true to the best of my knowledge and belief and I am aware that if any part of the data and information submitted is found to be false or misleading at any stage, the project will be rejected and clearance give, if any to the project will be revoked at our risk and cost. Date: Place: New Delhi-01 Rajeev Gupta (Authorized Signatory) C/O BPTP International Trade Centre Ltd M-11, Middle Circle, Connaught Circus, New Delhi Signature of the applicant With Name and Full Address (Project Proponent / Authorized Signatory) BPTP International Trade Center Ltd. 13

16 Sector - 94, ida FORM-1A FORM- 1A CAPITAL CITY COMMERCIAL PROJECT at Plot. 2B, Sector 94, ida, District: Gautam Budh Nagar, Uttar Pradesh M/s. BPTP INTERNATIONAL TRADE CENTRE LIMITED M-11, Middle Circle, Connaught Place, New Delhi BPTP International Trade Center Ltd. 13

17 Sector - 94, ida FORM-1A APPENDIX II (See paragraph 6) FORM-1 A (Only for construction projects listed under item 8 of the Schedule) CHECK LIST OF ENVIRONMENTAL IMPACTS (Project proponents are required to provide full information and wherever necessary attach explanatory notes with the Form and submit along with proposed environmental management plan & monitoring programme) 1. LAND ENVIRONMENT (Attach panoramic view of the project site and the vicinity) 1.1. Will the existing land use get significantly altered from the project that is not consistent with the surroundings? (Proposed landuse must conform to the approved Master Plan / Development Plan of the area. Change of landuse if any and the statutory approval from the competent authority be submitted). Attach Maps of (i) Site location, (ii) Surrounding features of the proposed site (within 500 meters) and (iii) The site (indicating levels & contours) to appropriate scales. If not available attach only conceptual plans List out all the major project requirements in terms of the land area, built up area, water consumption, power requirement, connectivity, community facilities, parking needs etc What are the likely impacts of the proposed activity on the existing facilities adjacent to the proposed site? (Such as open spaces, community facilities, details of the existing landuse, and disturbance to the local ecology). Commercial Project at Plot. 2B, Sector 94, ida, Uttar Pradesh The proposed project site does not involve any leveling of land outside the leased property. The existing topography will not be altered due to the construction activity. Hence, impacts on topography and land use will not be envisaged. Site location plan attached as annexure 4 Surrounding features of site (within 500 meters) enclosed as annexure 5 Conceptual plan enclosed as annexure 3 Plot Area: Sqm. or Acs. Built-up Area: Sqm. Ground Coverage: 14, Sqm. The likely impacts of the proposed activity on the existing facilities adjacent to the proposed site will be very meager. The proposed project will not have any adverse impact on the surrounding environment. However, the development of the project in this area will increase employment opportunities. There is no major disturbance to local ecology as no tree felling or clearing of vegetation is involved. The proposed project has a proposal of green belt development, which will increase the aesthetic value of the area. The project has a provision for planting of common variety / local trees and BPTP International Trade Center Ltd. 14

18 Sector - 94, ida FORM-1A 1.4. Will there be any significant land disturbance resulting in erosion, subsidence & instability? (Details of soil type, slope analysis, vulnerability to subsidence, seismicity etc may be given) Will the proposal involve alteration of natural drainage systems? (Give details on a contour map showing the natural drainage near the proposed project site) 1.6. What are the quantities of earthwork involved in the construction activity cutting, filling, reclamation etc. (Give details of the quantities of earthwork involved, transport of fill materials from outside the site etc?) 1.7. Give details regarding water supply, waste handling etc during the construction period Will the s & wetlands get altered? (Provide details of how low lying and wetlands are getting modified from the proposed activity) 1.9. Whether construction debris & waste during construction cause health hazard? (Give quantities of various types of wastes generated during construction including the construction labour and the means of disposal) 2. WATER ENVIRONMENT ornamental trees on the green belt area. The proposed activity will not affect any significant land disturbance resulting in soil erosion, subsidence and instability. The area is not susceptible to erosion. The total excavated quantity of excavated earth material were m 3 & already used for backfilling on own site for land development/horticulture development. There are no buildings or structures at the proposed site as no demolition work. Proper drainage system shall be provided to deal with the storm water in case of rain. There is no natural watercourse passing through the project site. Hence the proposal does not involve alteration of natural drainage systems. As a result of excavation of topsoil during construction phase, the impact on drainage pattern, and run off characteristics will be restricted to the small area and may not last more than one monsoon. Mainly the earthwork during construction involves excavation of soil & its quantum will be m 3, which has been used for backfilling and landscape/horticulture development. Requirement of water during the construction sourced from hired water tankers. The wastewater generated during this period has been disposed of in the mobile STPs and same practices will be in rest of the construction activities. The Solid waste generated during the construction phase like metal cuttings, debris, plastic material, wooden logs etc. being stored in scrap bin then segregated and disposed as per suitability. Conclusively, it can be stated that impacts may be confined to small area (mainly to project site) and for short duration. There are no wetlands near the project site. So, there will be no impact. The construction waste and debris are mainly metal cuttings; wooden logs, plastic material etc. collected and disposed. Domestic wastewater has been generated as a result of labourers. The Mobile STPs has been arranged for the treatment of the waste water generated. BPTP International Trade Center Ltd. 15

19 Sector - 94, ida FORM-1A 2.1. Give the total quantity of water requirement for the proposed project with the breakup of requirements for various uses. How will the water requirement met? State the sources & quantities and furnish a water balance statement What is the capacity (dependable flow or yield) of the proposed source of water? 2.3. What is the quality of water required, in case, the supply is not from a municipal source? (Provide physical, chemical, biological characteristics with class of water quality) 2.4. How much of the water requirement can be met from the recycling of treated wastewater? (Give the details of quantities, sources and usage) 2.5. Will there be diversion of water from other users? (Please assess the impacts of the project on other existing uses and quantities of consumption) 2.6. What is the incremental pollution load from wastewater generated from the proposed activity? (Give details of the quantities and composition of wastewater generated from the proposed activity) 2.7. Give details of the water requirements met from water harvesting? Furnish details of the facilities created What would be the impact of the land use changes occurring due to the proposed project on the runoff characteristics (quantitative as well as qualitative) of the area in the post construction phase on a long-term basis? Would it aggravate the problems of flooding or water logging in any way? The total water requirement for all purpose of the proposed project will be 1003 KLD which will be met from Municipal water supply. The daily requirement of fresh water for the proposed project during operational phase will be approx KLD, which will be met from Municipal water supply (ida Jal Board authority).s The quality of Existing Bore well water samples has been analyzed. All the parameters are well within the permissible limits and water can be used for drinking and domestic purposes. The estimated treated water available from Sewage Treatment Plant will be approximately 791 KLD. The re-use of treated water will be directly Green belt development, Flushing and water body make up. There will be zero discharge outside the boundary. there will be no diversion of water from other users. The waste water generated in the process will be approx. 791 KLD. The waste water will be treated in the STP and then the treated water will be recycled and used for Green belt development, flushing, etc. within the premises and no water will be discharged outside. There will be zero discharge. The rainwater harvesting will be done to recharge the ground water table. However, the company has already installed number of RWH pits as per requirements. The proposed project activity involves construction of buildings and development work such as construction of roads, lying of water supply, storm water drainage lines, sewer lines, street lighting and landscaping as such there will be no change in the land use of the site. Rainwater harvesting will be practiced to recharge the ground water during monsoon period. Therefore, the run-off characteristics of water in the area on long term basis will not change, as there will be no water logging and flooding problems. The project site does not fall in a flood prone area and hence no BPTP International Trade Center Ltd. 16

20 Sector - 94, ida FORM-1A 2.9. What are the impacts of the proposal on the Tube Well? (Will there be tapping of Tube Well; give the details of Tube Well table, recharging capacity, and approvals obtained from competent authority, if any) What precautions/measures are taken to prevent the run-off from construction activities polluting land & aquifers? (Give details of quantities and the measures taken to avoid the adverse impacts) 2.11.How is the storm water from within the site managed?(state the provisions made to avoid flooding of the area, details of the drainage facilities provided along with a site layout indication contour levels) Will the deployment of construction laborers particularly in the peak period susceptibility for floods and water logging. The Water table in the area is 10 to 15 m table. Tube Well water facility will be available as a supplement. The proposed building structure will have a rainwater-harvesting infrastructure. Beside wastewater will be treated and used in green belt development and to meet other soft requirements. Thus no major impact on groundwater due to tube well. The storm water disposal system for the premises shall be self-sufficient to avoid any collection/ stagnation and flooding of water. Maximum harvesting will be done within the site campus. Sufficient number of RWH pits at some selected locations will be provided, which are liable to catch the maximum run-off from the area. Approach for the same shall be as follows: To collect the run-off from all terraces and similar built areas through appropriately sized and number of rainwater pipes. The rain water from rainwater pipes and other open spaces will be collected through catch basins and then connected to the nearest drain through RCC/CI/LA pipes as per site conditions The final plinth levels, formation and ground levels are so decided that the rainwater follows the natural gradient and discharges into the external drainage system As per the site conditions, the network of external storm water system shall consist of an underground pipe drainage system with network of catch basins as per requirements The main emphasis given, in planning of storm water drainage system, is on recharging the underground aquifer on the campus while having the safe disposal of storm water without flooding any area Infiltration/RWH pits shall be provided at strategic locations on the storm water drainage system with a provision of 100% backup for overflow and bypass to both recharge the underground aquifer and aid in the disposal of storm water. The storm water disposal system for the premises shall be self-sufficient to avoid any collection/stagnation and flooding of water. Maximum harvesting will be done within respective project sites as per the requirement of local building byelaws. The proposed construction project has a provision of portable sanitation system during the construction period to handle the BPTP International Trade Center Ltd. 17

21 Sector - 94, ida FORM-1A lead to unsanitary conditions around the project site (Justify with proper explanation) What on-site facilities are provided for the collection, treatment & safe disposal of sewage? (Give details of the quantities of wastewater generation, treatment capacities with technology & facilities for recycling and disposal) Give details of dual plumbing system if treated waste used is used for flushing of toilets or any other use. 3. VEGETATION 3.1. Is there any threat of the project to the biodiversity? (Give a description of the local ecosystem with it s unique features, if any) 3.2. Will the construction involve extensive clearing or modification of vegetation? (Provide a detailed account of the trees & vegetation affected by the project) 3.3. What are the measures proposed to be taken to minimize the likely impacts on important site features (Give details of proposal for tree plantation, landscaping, creation of water bodies etc along with a layout plan to an appropriate scale) 4. FAUNA 4.1. Is there likely to be any displacement of fauna- both terrestrial and aquatic or creation of barriers for their movement? Provide the details Any direct or indirect impacts on the avifauna of the area? Provide details. 4.3.Prescribe measures such as corridors, fish ladders etc to mitigate adverse impacts on fauna unsanitary conditions in and around the project site. It is proposed to connect all the soil and waste Outlet pipes from Toilets, Kitchens, pantries, laundry and waste from floor washings etc. from all the floors into Vertical down take soil and waste pipes and bring them down to ground level and connect them to centralized sewer network for final disposal and treatment in the Sewage Treatment Plant. 711 KLD treated water will available for the project. Treated water will be used in green belt development, Flushing & water body make up. There will be no report of any adverse impacts on the biodiversity due to the construction of the proposed project. threatened, rare, endangered or endemic species were observed during the survey in core zone.. The proposed site to be developed as commercial complex. The acquired land earlier was occupied by NOIDA authority and said development as per NOIDA master plan Extensive plantation and green belt development is planned in the proposed project along with landscaping and creation of water bodies. The total green area shall be % (25, sqm) of plot area. There is no report of any direct or indirect impact on the fauna due to this proposed Commercial project and there is no report of existence of any specific fauna required special protection. There is no direct or indirect impact on avifauna is envisaged. However, after the commissioning of the project the better environmental conditions may provide a better habitat to the avifauna of the area. For the commercial colony project site, the area designated as green area will be about % (25, sqm) of plot area. Common native varieties of trees and ornamental flowering species will be planted in the green space. Landscaping can have direct positive impact on the local BPTP International Trade Center Ltd. 18

22 Sector - 94, ida FORM-1A avifauna as this will provide shelter to local birds. Adequate arrangement shall be made for fish ladders. 5. AIR ENVIRONMENT 5.1. Will the project increase atmospheric concentration of gases & result in heat islands? (Give details of background air quality levels with predicted values based on dispersion models taking into account the increased traffic generation as a result of the proposed constructions) 5.2. What are the impacts on generation of dust, smoke, odorous fumes or other hazardous gases? Give details in relation to all the meteorological parameters Will the proposal create shortage of parking space for vehicles? Furnish details of the present level of transport infrastructure and measures proposed for improvement including the traffic management at the entry & exit to the project site Provide details of the movement patterns with internal roads, bicycle tracks, pedestrian pathways, footpaths etc., with areas under each category Will there be significant increase in traffic noise & vibrations? Give details of the sources and the measures proposed for mitigation of the above., the project will not increase atmospheric concentration of gasses and result in heat islands. Gaseous pollutants like NOx, SO 2 & CO shall also be generated from activities like burning of fuel through DG sets, traffic movement, operation of construction machines/equipment and domestic activities at site. The project has provision to use only ultra low Sulphur fuel in the D.G. set to mitigate the pollution. Altogether construction activities will lead to dust generation, emission of NOx and fine particulates. Conclusively, dust and other emissions are unlikely to spread sufficiently to affect homes and other properties around the site hence are expected to result in degradation of air quality, primarily, in the working Environment affecting construction employees. The impacts on the ambient air quality during construction phase will be temporarily and reversible in nature (for short duration) and restricted to small area only., the proposal has sufficient parking space. Three level basements are proposed it will not create shortage of parking space. The grade separated facilities at entry/exit points will be proposed beyond the existing carriageway, which will not affect the existing traffic movement. All the applicable norms of ida Master Plan/IRC will be followed for formulation of road sections and profile. There will be a marginal increase in the traffic noise; the sources are due to traffic movement within the project area & Sufficient tree plantation will work as a noise barrier. BPTP International Trade Center Ltd. 19

23 Sector - 94, ida FORM-1A 5.6. What will be the impact of DG sets & other equipment on noise levels & vibration in & ambient air quality around the project site? Provide details. 6. AESTHETICS 6.1. Will the proposed constructions in any way result in the obstruction of a view, scenic amenity or landscapes? Do the proponents take these considerations into account? 6.2. Will there be any adverse impacts from new constructions on the existing structures? What are the considerations taken into account? 6.3. Whether there are any local considerations of urban form & urban design influencing the design criteria? They may be explicitly spelt out Are there any anthropological or archaeological sites or artifacts nearby? State if any other significant features in the vicinity of the proposed site have been considered. 7. SOCIO-ECONOMIC ASPECTS 7.1. Will the proposal result in any changes to the demographic structure of local population? Provide the details Give details of the existing social infrastructure around the proposed project Will the project cause adverse effects on local communities, disturbance to sacred sites or other cultural values? What are the safeguards proposed? 8. BUILDING MATERIALS Presently DG sets of 2000 KVA and 1000 KVA proposed to meet the power requirement during power failure and Fuel shall be ULSD. The power back up will be 100%. DG set will be the main source of noise pollution. The DG sets shall be used only in case of power failure and will be provide with acoustic enclosures. Gaseous pollutants like NOx, SO2 & CO shall also be generated from activities like burning of fuel through DG sets. The proposed proposal will not in any way result in the obstruction of a view scenic amenity or green belt. The present project itself is planned with provisions of green belt development and afforestation. This will surely enhance the aesthetic value of the area. There will not be any adverse impacts from new constructions as there are no existing structures nearby. The proposed project land is located in the commercial zone as per Master plan of ida The proposed project shall follow all the rules and regulations described by State Government, National Building Code and other relevant Departments. There are no any anthropological or archaeological sites or artifacts or any other significant features in the vicinity of the proposed project site. Telecommunication facilities in the study area are adequate; electronic telephone exchange is working the study area., the proposed project will not cause any adverse effects on local communities or disturbance to sacred sites or other cultural values. BPTP International Trade Center Ltd. 20

24 Sector - 94, ida FORM-1A 8.1. May involve the use of building materials with high-embodied energy. Are the construction materials produced with energy efficient processes? (Give details of energy conservation measures in the selection of building materials and their energy efficiency) 8.2. Transport and handling of materials during construction may result in pollution, noise & public nuisance. What measures are taken to minimize the impacts? 8.3 Are recycled materials used in roads and structures? State the extent of savings achieved? 8.4. Give details of the methods of collection, segregation & disposal of the garbage generated during the operation phases of the project. 9. ENERGY CONSERVATION 9.1. Give details of the power requirements, source of supply, backup source etc. What is the energy consumption assumed per square foot of built-up area? How have you tried to minimize energy consumption? 9.2. What type of, and capacity of, power back-up do you plan to provide? The major materials used for the construction of the proposed project will be RMC, steel, cement, bricks, metal, flooring tiles/stones, sanitary and hardware items, electrical fittings, water etc. All the items used in construction will be as per the National Building Code specification. The fly ash for mixing with the cement has been done and hence the disposal of fly ash which is a serious issue can be managed and will reduce the consumption of sand. Effort made to use bricks made of fly ash in place of loose earth for filling purposes within the building. Use of tiles made of fly ash as insulation material for the terrace. During the construction phase the air quality will have adverse impact. Construction activities especially related to handling of loose material like to cause generation of fugitive dust, that adversely impact the air quality of the surrounding area of the project site. To minimize the impact loose material will be either stacked or transported with proper covering. During construction phase the expected noise levels will be between db (A) which decrease with increase in distance. Administrative as well as engineering control of noise will be implemented. There is no availability of the recyclable building material in the vicinity of the proposed project site. Solid waste generated during the construction phase shall be properly collected and segregated as plastic, paper, metal and other and shall be disposed off as per the standard practice. The solid waste generated from project in operational phase shall be 5232 kg /day. The solid waste so generated shall be first segregated as plastic, glass, paper separately and disposed off as per standard practice. The power requirement for entire Project would be around 19.2 MVA. The power will be made available from UPPCL. Presently DG sets of 2000 KVA and 1000 KVA proposed to meet the power requirement during power failure and Fuel shall be HSD (Ultra-low Sulphur diesel). The power back up BPTP International Trade Center Ltd. 21

25 Sector - 94, ida FORM-1A 9.3. What are the characteristics of the glass you plan to use? Provide specifications of its characteristics related to both short wave and long wave radiation? 9.4. What passive solar architectural features are being used in the building? Illustrate the applications made in the proposed project? 9.5. Does the layout of streets & buildings maximize the potential for solar energy devices? Have you considered the use of street lighting, emergency lighting and solar hot water systems for use in the building complex? Substantiate with details Is shading effectively used to reduce cooling/heating loads? What principles have been used to maximize the shading of Walls on the East and the West and the Roof? How much energy saving has been effected? 9.7. Do the structures use energy-efficient space conditioning, lighting and mechanical systems? Provide technical details. Provide details of the transformers and motor efficiencies, lighting intensity and air-conditioning load assumptions? Are you using CFC and HCFC free chillers? Provide specifications. will be 100%. Tinted float glass will be used in the project. During commissioning of proposed project, 8 mm thick, blue / grey reflective glasses will be used in fenestration. These panels will have light transmission, but low solar heat inflow. This will reduce the quantity of heat inflow into the building, lessens cooling loads on AC induces energy saving. Solar energy will be utilized for providing Hot water supply to the buildings. Orientation is done in such a manner so that surface of the building is prevented from exposure to direct sunlight and thus heat gain of the building will less. The units on the top floor may have a false ceiling. The air in between the ceiling & slabs shall act as on insulator. The passive solar architecture is used for the maximum use of the solar energy. Large south facing windows are the easiest and cheapest way to increase light in a building, since the south side of a building receives the more sunlight. An open design, with glazed apertures, light shelves and light pipes can transmit sunlight into building interiors. Louvers and sunshades will be used around windows in order to protect from direct sunlight. Proper ventilation allows the heat from the sunspaces to circulate through the rest of the building. Suitable energy optimization will be adopted during calculation of energy load of the proposed project. Proper energy efficient system will be installed. The space heating load will be minimized using passive solar structure and suitable buildings envelop material. Uses of incandescent lamp and halogen lamps have been used for all common area and basement parking. The lights in basement car park has been designed to operate through timers to achieve 33%, 66% and 100% illustration to suit the occupation of the premises. The diesel generator sets shall be automatically controlled to BPTP International Trade Center Ltd. 22

26 Sector - 94, ida FORM-1A 9.8. What are the likely effects of the building activity in altering the microclimates? Provide a self-assessment on the likely impacts of the proposed construction on creation of heat island & inversion effects? 9.9. What are the thermal characteristics of the building envelope? (a) roof; (b) external walls; and (c) fenestration? Give details of the material used and the U- values or the Rvalues of the individual components What precautions & safety measures are proposed against fire hazards? Furnish details of emergency plans If you are using glass as wall material provides details and specifications including emissivity and thermal characteristics What is the rate of air infiltration into the building? Provide details of how you are mitigating the effects of infiltration. optimize their usage based on the actual load requirements at any time. Space conditioning will be provided as per norms of National Building Code Part 8. Due to the proposed project there would be insignificant emission of air pollutants by vehicular movements and occasional use of DG sets, hence no heat island effect is envisaged. To reduce the heat load reflective insulated glass shall be used in fenestrations to cut on heat loads and subsequently capital & operating cost of Air conditioning. The building construction material namely bricks, concrete and steel are being used in the construction. The R- values for concrete range from K.m. 2. W 1, which for steel range from K.m. 2. W- 1 and for bricks approx K.m. 2K.m. for fenestration, wood and glass panels and boards may be used, which have R value ranging from K.m. 2.W 1. U- Factor, also known as Thermal Transmittance, is heat transmission in unit time through unit area of a material or construction and the boundary air films, induced by unit temperature difference between the environments in each side. All floors shall have adequate firefighting equipment It is proposed to have fire water storage tank. The fire Detecting Equipments would be as per BIS and NBC norms. The other fire fighting measures proposed includes, an Emergency Control Room, Separate Fire Exit during emergency, all rooms with Fire detector / Smoke Detector, Fire extinguishers at each entry & exit point on each floor, Public address system etc. The fire Fighting Measures are backed by Electrical supply from D.G. sets in case of emergency. Glass with low emissive coating will be used. Windows manufactured low E coatings reduce energy loss by as much as 30-50%. Reduced air infiltration combined with proper ventilation cannot only reduce energy consumption but it can also improve the quality of indoor air. Outdoor air for which leakage account for 25-40% of energy used for heating and cooling in a typical building. For this purpose the building has been designed in a compact manner, leaving ventilation shafts in between for facilitating the escape of hot exhaust air To what extent the non-conventional After testing the viability, solar energy will also be used to BPTP International Trade Center Ltd. 23

27 Sector - 94, ida FORM-1A energy technologies are utilized in the overall energy consumption? Provide details of the renewable energy technologies used. meet electricity requirements. (For e.g.:- solar water heater, solar street light, use of Green CFL Lamps. 10. Environment Management Plan The Environment Management Plan would consist of all mitigation measures for each item wise activity to be undertaken during the construction, operation and the entire life cycle to minimize adverse environmental impacts as a result of the activities of the project. It would also delineate the environmental monitoring plan for compliance of various environmental regulations. It will state the steps to be taken in case of emergency such as accidents at the site including fire. Environmental aspects of building construction and operation should be addressed at planning stage by identifying Environmental goals and incorporating the requirements to be implemented. Further, while awarding the contract the knowledge and experience of the contractor shall be checked. If the contract has been tentatively finalized then the importance and implementation of Environmental issues should be discussed to ensure the best possible attention of Environmental aspects. The design team should work with the construction contractors to adopt following Environmental guidelines to be followed during construction: Construction specifications Purchasing construction materials Reducing site Environmental impacts Dust emission control during construction Optimized energy and water Use Runoff prevention and waste management. It is advisable for commercial project to integrate Environmental Management System (EMS) with Environmental requirements into its buildings to improve the Environmental BPTP International Trade Center Ltd. 24

28 Sector - 94, ida FORM-1A performance. A successful EMS facilitates a proactive approach to the Environment rather than reactive to a crisis situation. Mitigation measures specific to identify significant Environmental impacts during the construction and operation phases of the project are presented in below Tables. During construction phase, 06 monthly monitoring of ambient air, noise and groundwater to be done while during operation phase indoors air quality, ambient air quality, noise level need to be monitored on six monthly bases. Waste water quality also to be monitored on biannually basis. Both during construction and operation phases of the project, a dedicated person should be responsible to look after Environment, safety and health related issues for the project. Mitigation Measures and Environmental Management Plan during Construction Phase S.. Aspects/ Impact Remarks Mitigation Measures Management Plan 1. Land-use pattern/ Ecology Insignificant adverse impact 1. Construction footprint will be well defined and construction work will be carried out within the footprints only. Proper fencing of the area through contract 2. Restoring all areas affected by establishment of both within (open area) and adjacent to the plot area, if any during Construction. Audit of construction site to check the implementation of all the measures by the company personnel 2. Soil Moderate adverse impact 1. Stacking of excavated soil material (350,000 cu. m. approx.) in an earmarked area for leveling and every care shall be taken to prevent soil erosion. 2. Area shall be properly fenced and provided with proper drainage pattern. 3. Retention wall/bund shall be provided around the storage areas flow of solid with storm water in case of rain. Implemented through construction contractor and Audit and monitoring by the company personnel Do Do BPTP International Trade Center Ltd. 25

29 Sector - 94, ida FORM-1A S.. Aspects/ Impact Remarks Mitigation Measures Management Plan 4. Storage area will be kept away from the run-off prone area to prevent any wash away. 5. Excavated soil would be used for own site filling. 6. Attempts shall be made to use/transport the excavated soil at the earliest. 7. Collection and disposal of waste generated during construction such as metal cuttings debris, plastic packing material, wooden logs etc. 8. Sanitary waste disposal would be disposed through mobile STPs 9. Hazardous material, if any should be kept in isolated locations located away from the active construction zone. 10. The Contractor is required to excavate, store, transport and dispose of soil in a manner that limits the generation of dust, run off to the adjacent area and Drains and to minimize spillages in and around the site. Specially, if the Contractor adheres to the recommended guidelines given below, Environmental issues from soil excavation and handling can be significantly reduced. Do Do Do Audit and monitoring by the company personnel Do Do To be mentioned into the contractors contract Also to be briefed to the contractor before the start of the construction work Monitoring & Audit of soil management activities by contractors a. Avoid excavation activities during wet weather. b. Install silt fencing around the construction site where required. Apply gravel bags or berms to protect runoff to adjoining areas. c. Construct diversion dykes to channel runoff around the BPTP International Trade Center Ltd. 26

30 Sector - 94, ida FORM-1A S.. Aspects/ Impact Remarks Mitigation Measures Management Plan excavated site in case runoff occurs. d. The excavated area should be provided with temporary tin sheet wall to contain spillages and minimize fugitive emissions. e. Topsoil and other soil materials shall be stored separately to keep it in a reusable form. f. Cover exposed piles of soil materials with plastic sheeting or tarpaulin sheets. g. Stockpile/ Storage area shall have dykes to prevent runoff to adjoining area and silting of drains. h. Soil compactness to be avoided. Use gravel approaches on the part of land where truck traffic is frequent to reduce soil compaction and limit the tracking of sediment into streets. i. Do not wash down paved streets or pathways. Periodically street sweep sediment from paved roads. Use dry clean up system. Water spraying for dampening should be kept minimum (as per requirement). Keep soil materials out of the rain j. Soil that meets the criteria for onsite reuse should be reused wherever possible at projects identified by contractor's engineer. k. Topsoil can be spreaded in open spaces for plantation and leveling. l. Soil that is not suitable for reuse onsite should be removed approved landfill in coordination with local BPTP International Trade Center Ltd. 27

31 Sector - 94, ida FORM-1A S.. Aspects/ Impact Remarks Mitigation Measures Management Plan authority. m. Soil should be covered by tarpaulin sheets while transporting to disposal site. n. Preparation of checklist based for monitoring the above recommended points will help the contractors to reduce - impacts on the Environment from soil excavation and its handling. 3. Water Resource Moderate adverse impact 1. Ensure supply through the development authority 2. Optimization of water use by providing adequate networking / planning 3. Proper storage and internal supply facilities shall be developed before undertaking construction activities Company to approach To be taken up during designing stage with help of plumbing expert With help of construction contractor 4. Avoid spillage and leakage of water Audit by the company 5. If possible temporary rain water collection arrangements shall be made at site 6. Design of Low - Flow toilets, like urinals flushing capacity to be kept around 6 liters to conserve water Do Do 4. Water Quality Moderate adverse impact 1. During construction phase proper bunding will be made to prevent runoff to nearby water bodies To be discussed and implemented through construction contractors (of 1, 2 & 3 measures) 2. All the debris resulting from construction activities shall be removed from the site to prevent their runoff 3. Sewage generated will be fed to mobile STPs Regular water monitoring of groundwater quality to include parameters like SS, DO, coliformtotal nitrogen and oil and grease BPTP International Trade Center Ltd. 28

32 Sector - 94, ida FORM-1A S.. Aspects/ Impact Remarks Mitigation Measures Management Plan 5. Air Quality Moderate adverse impact 1. Dust generation will be reduced by using sharp teeth for excavation machinery Management Plans applicable to all the listed measures are as follows: 2. Dust suppression system (water spray) will be used at construction site and unpaved pathways/ roads which are to be used for transportation of the construction material within the site 3. During transportation, materials, shall be covered by tarpaulin sheets 4. A team of sweepers will be made available to remove dirt/debris from the floors/ sites Air monitoring shall be taken up time to time by appropriate external monitoring agency; Carryout vehicle pollution Check programme at regular intervals at the company facility. Regular audit by the company 5. Paint Polishes, building finings and flooring material etc. will be procured carefully to minimize VOCs emission 6. Extra care to be taken to procure new building products, which are not widely tested 7. All the D G Sets will have appropriate stack height i.e., 6 m from the roof top for each. 8. Company operated vehicle will go through regular maintenance and pollution check up 9. Also the private vehicles will be asked to have updated PUC (Pollution under control) certificate. 6. Ambient ise Moderate Adverse impact 1. Provision of rubber padding/noise isolators at equipment/machinery used for construction To be discussed and implemented through the contractors & suppliers 2. Provision of silencer to modulate the noise generated by machines Ambient noise monitoring shall be taken up time to BPTP International Trade Center Ltd. 29

33 Sector - 94, ida FORM-1A S.. Aspects/ Impact Remarks Mitigation Measures Management Plan 3. D.G. Sets will be kept in an enclosure 4. Provision of protective device like ear muff/ plugs to the workers time by appropriate external monitoring agency; 5. Major construction works will be limited to daylight working hours to avoid nuisance to residence 6. Construction vehicles will be well maintained, and not idling equipment or vehicles when not in use 7. Regular maintenance of company vehicles would be taken up. 7. Traffic Density Moderate adverse impact 1. Only well trained drivers will be hired for the vehicles Contractors to be instructed well in advance of the construction work 2. Vehicle movement and parking within the premises shall be manned properly to avoid accidents. Checked by the company personnel 8. House keeping & Safety Significant adverse impact 1. Attempts shall be made to keep the site clean by providing extra manpower Regularly audited by the company personnel 2. Proper marking shall be made for identification of locations of storages and waste collection and disposal as per their use Do 3. Proper system for collection and disposal of waste shall be implemented Do 4. Personal protective equipment for everybody present at site shall be made compulsory Do 5. All the required safety measures (working guidelines, use of personal protective equipments like gloves, helmets, ear muffs, safety Do BPTP International Trade Center Ltd. 30

34 Sector - 94, ida FORM-1A S.. Aspects/ Impact Remarks Mitigation Measures Management Plan belts etc.) for construction worker through the contractors 6. For safety of people occupying the site, regulations concerning fire safety shall be followed. Some of the requirements are as follows Installation of fire extinguishers Provision of water sprinklers in operative condition Emergency exit Proper labeling of exit and place of fire protective system installation Trained personnel to use fire control systems Display of phone numbers of the city/local fire services, etc. To be managed during building designing and furnishing through suitable contractors and also be monitored by the company 9. Ecology Positive impact could created be 1. The proposed commercial project should place emphasis on generating green cover through plantations. Stick to the plan as per the green space design as given 2. The plantation policy and selection of species should consider the overall architecture and landscaping of the design of the proposed project. 10. Socio- Economic Minor beneficial impact 1. Most of the man, machinery and material required for the construction shall be procured from local area only, which shall provide direct and indirect employment and business opportunities to locals. Mitigation Measures and Environmental Management Plan during Operation Phase Preference shall be given to local people in recruitment up to possible extent S.. Aspects/ Impact Remarks Mitigation Measures Management Plan 1. Air Quality Insignificant adverse 1. All the DG sets shall have appropriate stack height as per Regular indoor/outdoor environmental BPTP International Trade Center Ltd. 31

35 Sector - 94, ida FORM-1A S.. Aspects/ Impact 2. Water Resource 3. Water Quality 4. Ambient ise Remarks Mitigation Measures Management Plan impact Major adverse impact Moderate adverse impact Minor adverse CPCB norms. 2. Proper ventilation system shall be provided to all part of the building 3. Company operated vehicle will go through regular maintenance and pollution check up 4. Also the private vehicles will be asked to have updated PUC (Pollution Under Control) certificate 1. Ensure supply through the development authority 2. The building will be designed for higher water efficiency through a careful combination of design and water saving technology 3. Design of low flow toilets, like urinals flushing capacity to be kept around 6 Liters to conserve water 4. Infra red sensors will be installed in urinals to control wastage of water 5. Rain water harvesting system will be established within the building premises to recharge Bore Well with surplus rainwater 1. Wastewater generated during the building operation will be treated in sewage treatment plant and treated wastewater shall be reused for cooling purpose after additional treatment 2. Treated water of approximately 711 KLD shall use for flushing, and green belt development 3. During normal functioning of STP, total wastewater generated shall be reutilized after treatment. 1. The building and its wall designing shall be made to absorb the indoor monitoring shall be taken up by appropriate external monitoring agency All the measures to be monitored by the company Company to ensure To be taken up during building construction do do Regular monitoring of rainwater harvesting system should be done. State - of - art Sewage Treatment Plant will be installed Wastewater quality monitoring shall be carried out to ensure discharge wastewater compliance Installations of noise control equipments shall be taken care BPTP International Trade Center Ltd. 32

36 Sector - 94, ida FORM-1A S.. Aspects/ Impact Remarks Mitigation Measures Management Plan impact 5. Soil Moderate adverse impact 6. Traffic Density Minor adverse noise to great extent 2. Provision of boundary wall of height at least 2 m high to act as a noise barrier wall to attenuate at least 10 db (A) of noise levels so as to make the noise levels equal to the permissible corresponding standards. 3. Reflected noise shall be reduced by the use of absorbing material on roofs and walls 4. Provision of silencers at DG Sets to modulate the noise generation 5. Erecting suitable enclosures to minimize the impact of high noise generating sources 6. Ear plugs shall be provided to the personnel and provision for the green belt development around pumping and terminal to further attenuation of noise, 7. Regular maintenance of company vehicles. 1. D.G. Sets area /storage yards will have impervious concrete flooring/ sand bed to control diesel contamination of land/soil, 2. Hazardous material, if any should be kept in isolated building located away from the active working zone, 3. Waste generated during operation phase will be segregated and disposed off as per standard practices acceptable to regulatory bodies, 4. Sanitary waste disposal would be disposed through municipal sanitary disposal system, 5. Sludge generated from the STP will be used as manure 1. Only well trained drivers will be hired for the company vehicles 2. Periodic training of drivers will be during the construction phase through building contractors and DG Set suppliers Ambient (indoor and outdoor) noise monitoring will be carried out on regular basis by external agency All the measures monitored by the company Job Contract Regular audit and monitoring by the company Regular monitoring of all measures by the company personnel BPTP International Trade Center Ltd. 33

37 Sector - 94, ida FORM-1A S.. Aspects/ Impact 7. House keeping and safety 8. Socioeconomic Remarks Mitigation Measures Management Plan impact Minor adverse impact Minor beneficial impact carried out and 3. Vehicle movement and parking within the premise shall be manned properly to avoid accidents. 1. System shall be implemented to keep the area clean by providing adequate manpower 2. Proper marking shall be made for identification of locations of storages 3. Proper system for collection and disposal of waste shall be implemented 4. All the required safety measures (working guidelines, use of personal protective equipments like gloves, helmets, ear muffs, safety belts etc.) for any repair and maintenance work through the contractors 5. For safety of people occupying the building, regulations concerning fire safety shall be followed- Some of the requirements are: Installation of fire extinguishers all over the building Provision of water hydrants in operative condition Emergency exit Proper labeling of exit and place of fire protective system installation Conducting mock drills Trained personnel to use fire control systems Display of phone numbers of the city/local fire services, etc. 1. Preference shall be given to locals especially for semi-skilled and unskilled worker required for working in the project. 2. Most of the material required for the day-to-day basis shall be procured from local area only, which shall House keeping to be monitored and required arrangements and facilities to be provided (if observed any) Safety measures will be regularly checked by the company personnel and shall be improved as per the requirement. Detailed emergency response plan shall be developed Preference shall be given to the local people during recruitment by the company BPTP International Trade Center Ltd. 34

38 Sector - 94, ida FORM-1A S.. Aspects/ Impact 9. Ecology Significant beneficial Impact 10. Cultural/ Historical Remarks Mitigation Measures Management Plan Insignificant adverse impact provide direct and indirect employment and business opportunities to locals. 1. Development of Greenbelt 2. Plantations should be of trees that provide adequate shade and are evergreen to semi-evergreen. Deciduous trees can be used only for beautification of the area. 3. Species such as Bougainvillea, Tabubia etc. can be used for beautification, as it gives showy flowers 4. Development of Green belt, park and greenery in the open space of the Project Site Services of expert exterior designer and horticulturist shall be hired BPTP International Trade Center Ltd. 35

39 Sector - 94, ida, CONCEPTUAL PLAN CONCEPTUAL PLAN CAPITAL CITY COMMERCIAL PROJECT at Plot. 2B, Sector 94, ida, District: Gautam Budh Nagar, Uttar Pradesh M/s. BPTP INTERNATIONAL TRADE CENTRE LIMITED M-11, Middle Circle, Connaught Place, New Delhi BPTP International Trade Center Ltd. 36

40 Sector - 94, ida, CONCEPTUAL PLAN Table of Contents TABLE 1: AREA DETAILS TABLE 2: WATER CALCULATIONS TABLE 3: SOLID WASTE CALCULATION TABLE 4 : COMPOSITION OF WASTE FIGURE 1:WATER BALANCE DIAGRAM BPTP International Trade Center Ltd. 37

41 Sector - 94, ida, CONCEPTUAL PLAN 1. PROJECT LAYOUT AND DEVELOPMENT CONTEXT BPTP Limited was established in Today it is one of the key players in the real estate development industry. BPTP's promoters commenced business in real estate development in 1994 with primary focus on commercial properties. BPTP is a professionally managed and technology driven company, with a belief that ideas and innovations with the right action always bring in the desired growth. BPTP Ltd., since its inception, has engaged in developing various projects in & around the NCR. The promoter started off by building commercial office spaces in the capital. From there on, the company has stretched its arms into 4 major verticals of real estate i.e. Residential, IT-SEZ, Retail, Hospitality in the entire NCR i.e. Delhi, ida, Gurgaon and Faridabad. The existing business districts in Delhi are near saturation levels with limited space availability for future expansions. Majority of the developments undertaken have witnessed infrastructure bottlenecks, parking related issues, etc. To capitalize on this need gap, this project is ideally positioned to be developed as an iconic business district within the NCR region. Development of skyscrapers as part of this project would result in creation of a landmark, comparable to some of the popular business destinations worldwide The development of the proposed project is expected to house green buildings with sustainable design and green architecture to avail lower maintenance costs and environmental impacts, integrated to create constructive synergies. The development will encompass: the following components: Well designed office spaces - Catering to the corporate offices of the following sectors: BFSI, Manufacturing, Advertising / Media, Consulting, Telecom, etc. Hotels / Serviced Apartments /Conventional Centre Catering to the luxury & business needs Integrated Shopping Malls / High Street Retail Incorporating Retail and recreational facilities. Some of the key features of the development include: Green building concept to ensure environment friendly structures Multiple entry / exit points to the subject development to ensure smooth traffic flow BPTP International Trade Center Ltd. 38

42 Sector - 94, ida, CONCEPTUAL PLAN Superior security systems Professional building management solutions Globally distinguished architecture and planning Focus on Pedestrian Traffic On the whole, the pattern of development will optimize the flow and visibility of the site, with hotels at the center of the development with commercial spread across the radial road network. Further, retail developments through the circumference of the subject property are expected to have continuous frontage, creating visual aesthetics with green spaces. In effect, the development is envisaged to become one of a kind, integrated business hub in India The project is envisioned to benchmark itself to international standards like Canary Wharf in London, International Finance Centre in Hong Kong, and Dubai Business Bay in UAE with respect to its scale of operation, highly conducive environment for undertaking business operations and infrastructure which would in turn attract local, regional and international players. The complex shall be designed and developed in various phases with a master network of all services which can cater for the best Intelligent Buildings by any global standard. The Landscape for the entire complex shall be so designed (43.88 % of total plot area) that with a ground coverage restricted to 25%, the entire premises shall be plush green both in terms of hard and soft landscape. The building designs shall be such that the Concept of Green Building design is intact with a sound sustainability character. This project site is located in a very important junction amongst connectivity from Delhi, Greater ida, ida and Jasola. The importance of Traffic Management for such an important junction has been realized and we will ensure through the inputs of one of the best Traffic Consultants that the coordination between internal and external traffic is achieved as a seamless traffic interface The center of the complex shall be developed as the entertainment center running alive during day and especially evening hours. The pedestrian movement of the entire complex shall be controlled in a manner that the life is brought to the entire complex during all parts of day and night BPTP International Trade Center Ltd. 39

43 Sector - 94, ida, CONCEPTUAL PLAN The retail has been placed in the periphery of the complex for a perfect horizontal spread-out and a concept of high street shopping shall be implemented The area details of the Proposed Capital City Commercial Project at Plot. 1, Sector 94, ida (U.P.) is given in the below table: - Table 1: Area Details S. Particulars Area in Sq.Mt. 1. Total Plot Area (100 %) 57, Ground Coverage (24.87 %) 14, Proposed FAR Area 1,29, Total Built-up Area 2,73, Green Area (43.88 %) 25, Open Area 43, Total Paved Area (31.25%) 17, Parking Required 2931 ECS 9. Parking Provided 3136 ECS Table 2: Estimated Population S. Particulars FAR Area (in sq.m.) rms Population A Retail person/3 sq.m 17,019 of FAR of retail 4255 population of retail 12,764 population B Offices (4th person/ 6sq.m 9,810 Floor to 18 th Floor) of FAR of office 8,829 population of office 981 population C Cinema shows 3680 Visitors D Total 30,509 Total Capital Cost of the project: Crore. Total Power Requirement: MVA Source of Power: - UPPCL at 132 or 66 KV. D.G. sets for power back- up: - 11 DG sets (10 x 2000 KVA & 1 x 1000 KVA) BPTP International Trade Center Ltd. 40

44 Sector - 94, ida, CONCEPTUAL PLAN 2. WATER REQUIREMENT Total Water Requirement during operation phase= 1003 KLD. Total water requirement during construction phase = 100 m 3 / day (source: STP treated water from NOIDA Authority). Total wastewater generation will be = 791 KLD. All of this water will be treated in STP, which works on the principle of extended aeration. Treated water available will be = 711 KLD. This treated water will be used for Flushing, and Green belt development. Capacity of STP = 955 KLD. Source of Water = ida Jal Board (Municipal water supply) We have received permission from CGWA for ground water abstraction. S.. Particulars Table 3: Water Calculations Expected Population Base of Calculation (lpcd) Treated Water Fresh Water Total Water Consumption (KLD) Flushing (KLD) Other Domestic (KLD) (KLD) Other (KLD) 1. Working Staff (Retail + Offices + Cinema) 13, (30 lpcd for flushing and 15 lpcd for fresh water) Visitors (Retail + Offices + Cinema) 5. Horticulture(25, sq. m) 17, (9 lpcd for flushing and 6 lpcd for fresh water) 6 Lit / sq. m Total BPTP International Trade Center Ltd. 41

45 Sector - 94, ida, CONCEPTUAL PLAN Figure 1: Water Balance Diagram 3. SOLID WASTE GENERATION Total Solid Waste Generation: - Solid waste generated the project will be Kg / person/ day for commercial refuse and 0.15 kg/person/day for Visitors refuse as per CPHEEO manuals S.. Description of Population Table 4: Solid Waste Calculation Occupancy Waste Generated (Kg per capita / day) Waste Generated (kg/day) Municipal Solid waste 1. Working Staff Visitors Total 5231 Landscape Waste Area Landscape Waste 25, sq.m /6.22 acres Waste 0.2 kg/acre/day Total Waste Generation = 5232 kg/day BPTP International Trade Center Ltd. 42

APPENDIX I. (See paragraph-6) FORM 1

APPENDIX I. (See paragraph-6) FORM 1 (I) Serial Number Basic Information Item APPENDIX I (See paragraph-6) FORM 1 Details 1. Name of the project/s Soapstone Mining (ML. 15/95) 2. S.. in the schedule B1- Mining of Mineral 3. Proposed capacity/area/length/tonnage

More information

Application Forms for Prior Environmental Clearance as per Environmental Impact Assessment Notification dtd &

Application Forms for Prior Environmental Clearance as per Environmental Impact Assessment Notification dtd & Application Forms for Prior Environmental Clearance as per Environmental Impact Assessment Notification dtd 14-09-2006 & 01-12-09 To be submitted By Project Proponent To Madhya Pradesh State Environmental

More information

APPENDIX I. (See paragraph-6) FORM 1

APPENDIX I. (See paragraph-6) FORM 1 (I) Serial Number Basic Information Item APPENDIX I (See paragraph-6) FORM 1 Details 1. Name of the project/s Soapstone, Red Ocher and China Clay (ML. 81/82) 2. S.. in the schedule 1 (a) - Mining of Mineral

More information

FORM 1 & 1 A. Palladium Grand II RESIDENTIAL & COMMERCIAL DEVELOPMENT. Palladium Grand II, S. No. 17/1A/2, Dhanori, Pune, Maharashtra

FORM 1 & 1 A. Palladium Grand II RESIDENTIAL & COMMERCIAL DEVELOPMENT. Palladium Grand II, S. No. 17/1A/2, Dhanori, Pune, Maharashtra FORM 1 & 1 A Palladium Grand II RESIDENTIAL & COMMERCIAL DEVELOPMENT At Palladium Grand II, S. 17/1A/2, Dhanori, Pune, Maharashtra By M/s. Raojee Constructions FORM 1 Palladium Grand II RESIDENTIAL & COMMERCIAL

More information

APPENDIX I (See paragraph 6) FORM 1

APPENDIX I (See paragraph 6) FORM 1 APPENDIX I (See paragraph 6) FORM 1 (I) Basic Information: S.. Item Details 1 Name of the project/s: M/s. Sri Lakshmi Enterprises 2 S.. in the schedule 1 (a) 3. Proposed capacity/area/length/tonnage to

More information

Annex F Scoping Checklist

Annex F Scoping Checklist Scoping Checklist Table F1: Scoping Checklist Table. Questions to be considered in Scoping /? Which Characteristics of the Project 1. Will construction, operation or decommissioning of the Project involve

More information

Molvan- Chhamuchhal Group Gram Panchayat. Taluka- Mangrol, District- Surat. Ph. No

Molvan- Chhamuchhal Group Gram Panchayat. Taluka- Mangrol, District- Surat. Ph. No Serial Number FORM 1 (Application for Environment Clearance Certificate) Item 1. Name of the project/s 2. S. No. in the schedule 3. Proposed capacity/ area/ length/ tonnage to be handled/ command area/lease

More information

APPENDIX I (See paragraph 6) FORM 1

APPENDIX I (See paragraph 6) FORM 1 APPENDIX I (See paragraph 6) FORM 1 (I) Basic Information S. No Item Details 1 Name of the Project/s Sri A. Narasimulu 2 S. No in the Schedule 1(a) 3 Proposed capacity/area/length/tonnage to be handled/command

More information

M/s. Karthika Mines & Minerals Pvt.Ltd.-Colour Granite Quarry Ha. FORM - I

M/s. Karthika Mines & Minerals Pvt.Ltd.-Colour Granite Quarry Ha. FORM - I FORM - I (I) Basic Information S.. Item Details 1 Name of the project/s M/s.Karthika Mines & Minerals Pvt.Ltd. Colour Granite Quarry, 10.00 Ha. 2 S.. in the schedule 1 (B) 3 Proposed capacity Area-10.00

More information

(1) LAND ENVIRONMENT (Attach panoramic view of the project site and the vicinity)

(1) LAND ENVIRONMENT (Attach panoramic view of the project site and the vicinity) [Vide Paragraph - 6 of Notification dated 14 th September 2006, only for construction projects listed under item 8 of the Schedule] (1) LAND ENVIRONMENT (Attach panoramic view of the project site and the

More information

APPENDIX I (See paragraph - 6) FORM 1

APPENDIX I (See paragraph - 6) FORM 1 APPENDIX I (See paragraph - 6) FORM 1 (I) Basic Information S. Item Details 1 Name of the project Sarpanch, Gram Panchayat chando chando Sand Mine 2 S.. in schedule Category B, Project or Activity 1(a)

More information

FORM I SUBMISSION TO STATE ENVIRONMENT IMPACT ASSESSMENT AUTHORITY, ANDHRA PRADESH. BY. Asst.Director of Mines and Geology, Rajamahendravaram

FORM I SUBMISSION TO STATE ENVIRONMENT IMPACT ASSESSMENT AUTHORITY, ANDHRA PRADESH. BY. Asst.Director of Mines and Geology, Rajamahendravaram FORM I SUBMISSION TO STATE ENVIRONMENT IMPACT ASSESSMENT AUTHORITY, ANDHRA PRADESH. BY Asst.Director of Mines and Geology, Rajamahendravaram Ordinary Sand Land Details : Govt Land Extent : 3.9634 Ha. VILLAGE

More information

FORM-I. 13. Name of Applicant District Collector Nasik 14. Registered Address Address : Collector Office, Nasik

FORM-I. 13. Name of Applicant District Collector Nasik 14. Registered Address Address : Collector Office, Nasik FORM-I (I) Basic Information Item Details. 1. Name of the Project Proposal for Sand Quarry in Kas Village, Taluka Trimbakeshwar, District Nasik, State Maharashtra over an area of 1.5400 Ha at Damanganga

More information

Application Forms for Prior Environmental Clearance as per Environmental Impact Assessment Notification dtd &

Application Forms for Prior Environmental Clearance as per Environmental Impact Assessment Notification dtd & Application Forms for Prior Environmental Clearance as per Environmental Impact Assessment tification dtd 14-09-2006 & 01-12-09 To be submitted By SHRI SANJAY SINGH S/O SHRI MAHENDRA SINGH RATHORE To Madhya

More information

FORM 1. 8 Does it attract the specific condition? It yes, No Please specify 9 Location At Village Akurli, Akurli Road, Kandivali(E), Mumbai

FORM 1. 8 Does it attract the specific condition? It yes, No Please specify 9 Location At Village Akurli, Akurli Road, Kandivali(E), Mumbai FORM 1 (I) Basic Information Sr. Item Details. 1 Name of the Project WHITE CITY METAL 2 S.. in the Schedule 8 (b) 3 Proposed capacity/area /length/tonnage to Plot area: 45,800.00 sq.mt. be handled/command

More information

APPENDIX I (See paragraph 6) FORM 1 (Application for Environment Clearance)

APPENDIX I (See paragraph 6) FORM 1 (Application for Environment Clearance) (I) Basic Information APPENDIX I (See paragraph 6) FORM 1 (Application for Environment Clearance) Name of the Project: KRUTI ONELLA Sahyog Rekha Infraproject LLP Location / site alternatives Survey no.

More information

Form -1. [Vide Notification dated 1 st December 2009] FOR PROPOSED. COSTAL ROAD AT DRONAGIRI, NAVI MUMBAI Precast RCC Bridges On Holding Ponds-

Form -1. [Vide Notification dated 1 st December 2009] FOR PROPOSED. COSTAL ROAD AT DRONAGIRI, NAVI MUMBAI Precast RCC Bridges On Holding Ponds- Project Name : Design and Construction of Precast Arch Bridges(3s.) on Holding Pond. 3A, 3 & 4 for Form -1 [Vide tification dated 1 st December 2009] FOR PROPOSED COSTAL ROAD AT DRONAGIRI, NAVI MUMBAI

More information

FORM 1 BASIC INFORMATION S.NO.

FORM 1 BASIC INFORMATION S.NO. FORM 1 BASIC INFORMATION S.NO. Item Details 1 Name of the Project M/s AVA Stones (P) Ltd, Director: Sri.Bimal Kumar Agarwal Colour Granite Mine. 2 S.. in the schedule 1(a) 3 Proposed capacity/ area/ length/

More information

APPENDIX I. (See paragraph 6) FORM 1

APPENDIX I. (See paragraph 6) FORM 1 APPENDIX I (See paragraph 6) FORM 1 (I) Basic Information Name of the Project Size of the project (in terms of total area) CRZ classification of the area Expected cost of the project Contact Information

More information

APPENDIX- I FORM- 1. (I) Basic Information:

APPENDIX- I FORM- 1. (I) Basic Information: (I) Basic Information: APPENDIX- I FORM- 1 Item Details 1. Name of Project Sand Stone Mining Project, M.L..-08/1987, Area 150.926 Ha., located n/v -Gubrenda, Tehsil -Karauli, District Karauli, (Rajasthan)

More information

FORM I TERMS OF REFERENCE. For. QUARRY OF ROAD METAL (6.265 Ha) Sri K Kasi Raju. PROP: K.Kasi Raju

FORM I TERMS OF REFERENCE. For. QUARRY OF ROAD METAL (6.265 Ha) Sri K Kasi Raju. PROP: K.Kasi Raju FORM I TERMS OF REFERENCE For QUARRY OF ROAD METAL (6.265 Ha) Of Sri K Kasi Raju PROP: K.Kasi Raju Extent: 6.265 Ha of Budawada (V), Chimskurthy (M), Prakasam (Dt), Andhra Pradesh (I) BASIC INFORMATION

More information

FORM-I for seeking clearance for project attracting CRZ notification

FORM-I for seeking clearance for project attracting CRZ notification AnnexureIV FORM-I for seeking clearance for project attracting CRZ notification Basic information: SEA CLIFF RESORTS TOURISM PROJECT (.1682/A3/15/KCZMA/S&TD) Name of the Project: THE SEACLIFF Location

More information

APPENDIX I (See paragraph 6) Form 1 (I) Basic Information

APPENDIX I (See paragraph 6) Form 1 (I) Basic Information APPENDIX I (See paragraph 6) Form 1 (I) Basic Information Sr.. Item Details 1 Name of the Project/s Proposed expansion in Environment Clearance for Residential and Commercial project by Manikchand Kumar

More information

FORM 1. APPLICATION FOR OBTAINING ENVIRONMENTAL CLEARANCE VIDE PARA 6 OF S.O.1533 OF MOEF NOTIFICATION DATED 14 th SEPTEMBER 2006

FORM 1. APPLICATION FOR OBTAINING ENVIRONMENTAL CLEARANCE VIDE PARA 6 OF S.O.1533 OF MOEF NOTIFICATION DATED 14 th SEPTEMBER 2006 FORM 1 APPLICATION FOR OBTAINING ENVIRONMENTAL CLEARANCE VIDE PARA 6 OF S.O.1533 OF MOEF NOTIFICATION DATED 14 th SEPTEMBER 2006 (I) Basic Information: S. Item Details 1. Name of the Project/s : Expansion

More information

(Residential cum Commercial Project) APPENDIX I (See paragraph 6) FORM 1. Plot area: 37,039 m 2 Built up area: 1,11, m 2

(Residential cum Commercial Project) APPENDIX I (See paragraph 6) FORM 1. Plot area: 37,039 m 2 Built up area: 1,11, m 2 (I) Basic Information APPENDIX I (See paragraph 6) FORM 1 Sr. Item 1 Name of the Project 2 S. number in schedule 8(a) 3 Proposed capacity/area/length/tonnage to be handled/command area/lease area/number

More information

APPENDIX - I (See paragraph 6) FORM 1

APPENDIX - I (See paragraph 6) FORM 1 APPENDIX - I (See paragraph 6) FORM 1 (I) Basic Information Item Details 1 Name of the project/s M/S Jashnani Constructions Pvt. Ltd. Proposed residential building project at Shahapur, Thane 2 S.. in the

More information

Proposed Construction Multi Specialty Hospital Naruvi Hospitals 2. S. No. in the schedule 8(a)

Proposed Construction Multi Specialty Hospital Naruvi Hospitals 2. S. No. in the schedule 8(a) FORM I (I) Basic Information S.. Item Details 1. Name of the project Proposed Construction Multi Specialty Hospital Naruvi Hospitals 2. S.. in the schedule 8(a) 3. Proposed capacity/area/length/tonnage

More information

Appendix I. Form 1 BASIC INFORMATION PAWA MASONARY STONE MINING PROJECT VILLAGE PAWA, TEHSIL DIDWANA, DISTRICT NAGAUR, RAJSTHAN

Appendix I. Form 1 BASIC INFORMATION PAWA MASONARY STONE MINING PROJECT VILLAGE PAWA, TEHSIL DIDWANA, DISTRICT NAGAUR, RAJSTHAN Appendix I Form 1 BASIC INFORMATION PAWA MASONARY STONE MINING PROJECT VILLAGE PAWA, TEHSIL DIDWANA, DISTRICT NAGAUR, RAJSTHAN AREA: 1.0 HECT (NON FOREST LAND) ML 219/1997 PRODUCTION CAPACITY: 50,000 TPA

More information

APPENDIX I (See paragraph 6) FORM 1

APPENDIX I (See paragraph 6) FORM 1 (I) Basic Information APPENDIX I (See paragraph 6) FORM 1 Sr. Item Details 1 Name of the Project WHITE LILLIES (Residential Project) 2 S. number in schedule 8(a) Proposed 3 capacity/area/length/tonnage

More information

Submitted To State Expert Appraisal Committee (SEAC), State Environmental Impact Assessment Authority, Andhra Pradesh.

Submitted To State Expert Appraisal Committee (SEAC), State Environmental Impact Assessment Authority, Andhra Pradesh. Application for Prior Environmental Clearance (Form 1) For Proposed Colour Granite Mine over an Extent of 3.000 Hectares, in Sy. : 143 of Bharthupuram village, Nandigam Mandal, Srikakulam District, Andhra

More information

APPENDIX I (See paragraph 6) FORM 1. Plot area: 10,439 m 2 Built up area: 50, m 2

APPENDIX I (See paragraph 6) FORM 1. Plot area: 10,439 m 2 Built up area: 50, m 2 (I) Basic Information APPENDIX I (See paragraph 6) FORM 1 Sr. Item 1 Name of the Project Commercial Project 2 S. number in schedule 8(a) Proposed 3 capacity/area/length/tonnage to be handled/command area/lease

More information

UPDATED FORM I. SUBMISSION To Ministry of Environment & Forests & Climate Change, New Delhi. Prepared by. M/s. VIJAYNAGAR SUGAR PVT. LTD.

UPDATED FORM I. SUBMISSION To Ministry of Environment & Forests & Climate Change, New Delhi. Prepared by. M/s. VIJAYNAGAR SUGAR PVT. LTD. Annexure - III UPDATED FORM I For Amendment to Environmental Clearance (Environmental Clearance issued by MOEF vide. F.. J-11011/366/2007-IA-II (I) Dated, 15.04.2008.) SUBMISSION To Ministry of Environment

More information

APPENDIX I (See paragraph 6) FORM 1. Plot area: 13,114 m 2 Built up area: 81, m 2

APPENDIX I (See paragraph 6) FORM 1. Plot area: 13,114 m 2 Built up area: 81, m 2 (I) Basic Information APPENDIX I (See paragraph 6) FORM 1 Sr. Item 1 Name of the Project Residential Project 2 S. number in schedule 8(a) Proposed 3 capacity/area/length/tonnage to be handled/command area/lease

More information

No 1 Name of the Project/s M/s. Velchal Laterite Mine 2 S. No in the Schedule 1(a)

No 1 Name of the Project/s M/s. Velchal Laterite Mine 2 S. No in the Schedule 1(a) APPENDIX I (See paragraph 6) FORM 1 (I) Basic Information S. Item Details No 1 Name of the Project/s 2 S. No in the Schedule 1(a) 3 Proposed capacity/area/length/tonnage to Mine lease area is 8.91 Ha,

More information

FORM - I-A CHECK LIST OF ENVIRONMENTAL IMPACTS

FORM - I-A CHECK LIST OF ENVIRONMENTAL IMPACTS FORM - I-A CHECK LIST OF ENVIRONMENTAL IMPACTS 1. LAND ENVIRONMENT QUERY 1.1 Will the existing land use get significantly altered from the project that is not consistent with the surroundings? Attach Maps

More information

Sri.T.N.Balasubramanya

Sri.T.N.Balasubramanya Sri.T.N.Balasubramanya (Earlier: M/s.Global Golden Rocks) Extent: 5 Ha Colour Granite Quarry Sy.No.65 of Lattigam Village, Nandigam Mandal, Srikalulam District, Andhra Pradesh UPDATED FORM-I FORM 1 (As

More information

UPDATED FORM I, (Submitted to State Expert Appraisal Committee, Telangana)

UPDATED FORM I, (Submitted to State Expert Appraisal Committee, Telangana) UPDATED FORM I, (Submitted to State Expert Appraisal Committee, Telangana) Venkateswara Mines & Minerals (Earlier: Sri Bode Vijayasen Reddy), Kannaraopet Village, Nallabelli Mandal, JayashankarBhupalpally

More information

FORM I. [Vide M.o.E.F & C.C Notification dated 14 th September, 2006] For Proposed Residential & Commercial Project ALCOVE. M/s.

FORM I. [Vide M.o.E.F & C.C Notification dated 14 th September, 2006] For Proposed Residential & Commercial Project ALCOVE. M/s. FORM I [Vide M.o.E.F & C.C tification dated 14 th September, 2006] For Proposed Residential & Commercial Project ALCOVE At. 100/1, 100/2, 100/3, 100/4, 100/5, 100/6B, 101/1, 101/2, 101/3, 101/4, 101/5B,

More information

Form I. for. Proposed Construction of High Rise Residential Cum Commercial Building Eco Gardens

Form I. for. Proposed Construction of High Rise Residential Cum Commercial Building Eco Gardens Form I for Proposed Construction of High Rise Residential Cum Commercial Building Eco Gardens at T.P.S. 2, F.P.. 182/P, Sub Plot-A, OP. 43, R.S.. 85/P Vesu-Bhartana-Vesu, Tal: Choryasi Dist: Surat, Gujarat

More information

Proposed Multiplex & Commercial Complex FORM I

Proposed Multiplex & Commercial Complex FORM I I. BASIC INFORMATION FORM I. Item Details 1 Name of the project Proposed Construction of Multiplex cum Commercial Complex 2 no. in the schedule 8 (a) 3 Proposed area Area Details: Total land area: 13,218.80

More information

Project: Bhidauni Khadar Ordinary Sand Mining Project on Yamuna River FORM 1 Applicant: M/s Satyug Foods Pvt. Ltd. FORM- I

Project: Bhidauni Khadar Ordinary Sand Mining Project on Yamuna River FORM 1 Applicant: M/s Satyug Foods Pvt. Ltd. FORM- I FORM- I Page 0 of 14 APPENDIX I (See paragraph 6) FORM 1 (I) Basic Information S.. Item Details 1. Name of the project/s Bhidauni Khadar Ordinary Sand Mining Project 2. S.. in the schedule 1(a) mining

More information

APPENDIX I (See paragraph - 6) FORM 1

APPENDIX I (See paragraph - 6) FORM 1 APPENDIX I (See paragraph - 6) FORM 1 (I)Basic Information S. Item Details 1 Name of the project 1.79Acr nakti Limestone Mines (Minor Mineral) 2 S.. in schedule Category B, Project or Activity 1(a) (As

More information

FORM 1 (As per new Notification of MoEF dated vide S.O 3067 (E))

FORM 1 (As per new Notification of MoEF dated vide S.O 3067 (E)) FORM 1 (As per new tification of MoEF dated 01-12-2009 vide S.O 3067 (E)) (I) BASIC INFORMATION S.. Item Details 1. Name of the project/s M/s. S.L.N.S. Granites Mining of Colour Granite 4.90 Ha 2. S..

More information

FORM 1. 1 Name of the Project Pinakin Mangubhai Patel 2 S. number in schedule 8 (a)

FORM 1. 1 Name of the Project Pinakin Mangubhai Patel 2 S. number in schedule 8 (a) FORM 1 (I) Basic Information Item Details 1 Name of the Project Pinakin Mangubhai Patel 2 S. number in schedule 8 (a) 3 Proposed capacity/ area/ length/ tonnage to be handled/command area/lease area/number

More information

FORM 1 FOR PROPOSED CONSCTRUCTION BUILDING PROJECT ( SQ. M) ANAMOL LIFE STYLE

FORM 1 FOR PROPOSED CONSCTRUCTION BUILDING PROJECT ( SQ. M) ANAMOL LIFE STYLE FORM 1 FOR PROPOSED CONSCTRUCTION BUILDING PROJECT (22309.63 SQ. M) AT ANAMOL LIFE STYLE RESIDENTIAL CUM COMMERCIAL BUILDING S. No. 206, O.P. NO. 129, F.P. NO. 129 OF D.T.P.S. NO. 241, NANA CHILODA, GANDHINAGAR,

More information

FORM 1 (Application for Environment Clearance)

FORM 1 (Application for Environment Clearance) (I) Basic Information APPENDIX I (See paragraph 6) FORM 1 (Application for Environment Clearance) Name of the Project: Location / site alternatives under consideration: Size of the Project: Shreedhar Sparsh

More information

Sand, Stone & Bajri Mining Project Applicant: Shri Ashish Kumar, M/s Ashish Stone Crusher. Form-1 FORM-1 SRUSHTI SEWA, NAGPUR 1

Sand, Stone & Bajri Mining Project Applicant: Shri Ashish Kumar, M/s Ashish Stone Crusher. Form-1 FORM-1 SRUSHTI SEWA, NAGPUR 1 FORM-1 SRUSHTI SEWA, NAGPUR 1 FORM 1 (I) Basic Information S.. Item Details 1. Name of the project/s Sand, Stone and Bajri Mining Project 2. Serial. in the schedule 1(a) Mining of Mineral 3. Proposed capacity

More information

APPENDIX I (See paragraph - 6) FORM 1

APPENDIX I (See paragraph - 6) FORM 1 APPENDIX I (See paragraph - 6) FORM 1 (I) Basic Information S. Item Details 1 Name of the project Ambey Mahila Swa Sahayata Samuh 2 S.. in schedule Category B, Project or Activity 1(a) (As per EIA tification

More information

ITHC/PRJ/18-19/EIA/138 1 IND TECH HOUSE CONSULT

ITHC/PRJ/18-19/EIA/138 1 IND TECH HOUSE CONSULT Application for Extension of Environmental Clearance (EC) UPDATED (See Paragraph 6 tification dated14 th September 2006) as amended to EIA tification, 2006 issued vide S.O. 3067(E) on dt. 01.12.2009. Basic

More information

APPENDIX I (See paragraph - 6) FORM 1

APPENDIX I (See paragraph - 6) FORM 1 APPENDIX I (See paragraph - 6) FORM 1 (I) Basic Information S. Item Details 1 Name of the project 3.274 Ha Kapsada Limestone Mines (Minor Mineral) of M/s I.V.R.C.L Limited 2 S.. in schedule Category B,

More information

FORM-1. PROJECT: Sati & Garhi Sand Ghat,Ulai River (Area-22 Ha), Dist:-Jamui. APPLICANT: M/s Westlink Trading Pvt. Ltd. FORM- I.

FORM-1. PROJECT: Sati & Garhi Sand Ghat,Ulai River (Area-22 Ha), Dist:-Jamui. APPLICANT: M/s Westlink Trading Pvt. Ltd. FORM- I. FORM- I Page 0 of 15 APPENDIX I (See paragraph 6) FORM 1 (I) Basic Information S.. Item Details 1. Name of the project/s Sati & Garhi Sand Ghat on Ulai River of District- Jamui. 2. S.. in the schedule

More information

FORM 1. Gownivaripalli Village, Tehsil. Gorantla Mandal, District. Anantapur District, State

FORM 1. Gownivaripalli Village, Tehsil. Gorantla Mandal, District. Anantapur District, State FORM 1 (I) Basic Information Sl.. Item Details 1. Name of the project/s M/s. Squadm Mines & Minerals Pvt. Ltd - Road Metal & Building Stone 2. S.. in the schedule Item- 1(a) (Mining of Minerals) 3. Proposed

More information

Expansion of MDI Complex, Plot No 25, Sector 16A, Noida, Uttar Pradesh

Expansion of MDI Complex, Plot No 25, Sector 16A, Noida, Uttar Pradesh Plot 25, Sector 16A, ida, Uttar Pradesh (I) Basic Information FORM- I S.. Item Details 1. Name of the project/s Expansion of MDI Complex 2. S.. in the schedule 8 (a) 3. Proposed capacity/ area/ length/

More information

FORM-1. Sr. No 1 Name of the Project Harbour Heights 2 S. No. in the Schedule 8(b) Townships and Area Development projects.

FORM-1. Sr. No 1 Name of the Project Harbour Heights 2 S. No. in the Schedule 8(b) Townships and Area Development projects. (I) Basic Information FORM-1 Item Details 1 Name of the Project Harbour Heights 2 S.. in the Schedule 8(b) Townships and Area Development projects. 3 Proposed capacity/area /length/tonnage to be Total

More information

9 Plot/Survey/Khasra No S.No: 153/1, 153/2, 171/1, 171/2A, 172/1B1, 172/1B2, 172/C1, 172/1C2, 172/2A, 172/2B, 172/2C & 180/1.

9 Plot/Survey/Khasra No S.No: 153/1, 153/2, 171/1, 171/2A, 172/1B1, 172/1B2, 172/C1, 172/1C2, 172/2A, 172/2B, 172/2C & 180/1. FORM I I. BASIC INFORMATION Item Details 1 Name of the project Proposed construction of residential building by M/s. CASA GRANDE AXIOM PRIVATE LIMITED. 2 no. in the schedule 8 (a) 3 Proposed area Area

More information

Centrade At Plot No. 1, Sector 140, NOIDA Noida, U.P FORM- I

Centrade At Plot No. 1, Sector 140, NOIDA Noida, U.P FORM- I At Plot. 1, Sector 140, NOIDA ida, U.P FORM- I (I) Basic Information S.. Item Details 1. Name of the project/s Centrade 2. S.. in the schedule 8 (a) 3. Proposed capacity/ area/ length/ tonnage to be handled/

More information

A 'N 'E B 'N 'E C 'N 'E D 'N 'E

A 'N 'E B 'N 'E C 'N 'E D 'N 'E Gata. 12, Gata. 164, 352 & 1295/5 Basic Information FORM- 1 S.. Item Details 1. Name of the project/s Sand/Moram Mining 2. S.. in the schedule 1(a)i 3. Proposed capacity/area/length/tonnage to be handled

More information

FORM-I. Sector-16-B, GH Greater Noida, U.P.

FORM-I. Sector-16-B, GH Greater Noida, U.P. ida, U.P. APPENDIX I (See paragraph-6) FORM 1 S.. Item Details 1. Name of the project/s Residential Complex entitled Ajnara Homes by M/s APV Reality Ltd. 2. S.. in the schedule 8 (b): Township and Area

More information

UPDATED FORM-1 EXTENSION OF VALIDITY OF ENVIRONMENTAL CLEARANCE. Sri Fakir Rohidas

UPDATED FORM-1 EXTENSION OF VALIDITY OF ENVIRONMENTAL CLEARANCE. Sri Fakir Rohidas UPDATED FORM-1 EXTENSION OF VALIDITY OF ENVIRONMENTAL CLEARANCE At: Brahmanipali, Dustrict: Sambalpur, Odisha Sri Fakir Rohidas Prepared By Centre for Envotech and Management Consultancy Pvt. Ltd. Bhubaneswar

More information

APPENDIX VIII (See paragraph 6) FORM 1 M APPLICATION FOR MINING OF MINOR MINERALS UNDER CATEGORY B2 FOR LESS THAN AND EQUAL TO FIVE HECTARE

APPENDIX VIII (See paragraph 6) FORM 1 M APPLICATION FOR MINING OF MINOR MINERALS UNDER CATEGORY B2 FOR LESS THAN AND EQUAL TO FIVE HECTARE APPENDIX VIII (See paragraph 6) FORM 1 M APPLICATION FOR MINING OF MINOR MINERALS UNDER CATEGORY B2 FOR LESS THAN AND EQUAL TO FIVE HECTARE (II) (viii) (ix) (x) Basic Information Name of the Mining Lease

More information

(I) Basic Information:

(I) Basic Information: (I) Basic Information: Item Details 1 Name of the project Proposed River Bed Ordinary Sand Mining At River Sharda, Village- Mudi, Gata - 443, Tehsil- Dhaurahra, District-Khiri, State-Uttar Pradesh. (Leased

More information

FORM I I. BASIC INFORMATION S. No. Proposed Mixed Use Development Project SPR Binny 2 S. no. in the schedule 8 (b) 1 Name of the project

FORM I I. BASIC INFORMATION S. No. Proposed Mixed Use Development Project SPR Binny 2 S. no. in the schedule 8 (b) 1 Name of the project FORM I I. BASIC INFORMATION. Item Details 1 Name of the project Proposed Mixed Use Development Project SPR Binny 2 no. in the schedule 8 (b) 3 Proposed area Area Details: Total land area: 200243.50 Sqm

More information

.APPENDIX I (See paragraph 6) FORM 1. Sl. No. Item Details 1. Name of the project/s

.APPENDIX I (See paragraph 6) FORM 1. Sl. No. Item Details 1. Name of the project/s .APPENDIX I (See paragraph 6) FORM 1 (I) Basic Information. Item Details 1. Name of the project/s Peddayekkaluru White Shale Mine M/s. Swathi Mines 2.. in the schedule Proposed capacity/area/length/ tonnage

More information

APPENDIX VIII (See paragraph 6) FORM 1 M APPLICATION FOR MINING OF MINOR MINERALS UNDER CATEGORY B2 FOR LESS THAN AND EQUAL TO FIVE HECTARE

APPENDIX VIII (See paragraph 6) FORM 1 M APPLICATION FOR MINING OF MINOR MINERALS UNDER CATEGORY B2 FOR LESS THAN AND EQUAL TO FIVE HECTARE APPENDIX VIII (See paragraph 6) FORM 1 M APPLICATION FOR MINING OF MINOR MINERALS UNDER CATEGORY B2 FOR LESS THAN AND EQUAL TO FIVE HECTARE (AI) (viii) (ix) (x) Basic Information Name of the Mining Lease

More information

FORM 1. Basic Information Sr. No. 1 Name of the project River Sand Mining Project of Shree Sabarmati Majur Kamdar Sahakari Mandali LTD.

FORM 1. Basic Information Sr. No. 1 Name of the project River Sand Mining Project of Shree Sabarmati Majur Kamdar Sahakari Mandali LTD. FORM 1 Basic Information Item Details 1 Name of the project River Sand Mining Project of Shree Sabarmati Majur Kamdar Sahakari Mandali LTD. located at Survey : 64 ne Lagu, Sabarmati Nadi Patt Village:

More information

FORM 1 (As per new Notification of MoEF dated vide S.O 3067 (E))

FORM 1 (As per new Notification of MoEF dated vide S.O 3067 (E)) FORM 1 (As per new Notification of MoEF dated 01-12-2009 vide S.O 3067 (E)) I) BASIC INFORMATION Item Details 1 Name of the project/s Sri.Gandi Suryanarayana color Granite 2 S. No. in the schedule Item

More information

556/2C2,3B2,4A,5B,6B,7,8,9,10,11A,12A, 12B2,

556/2C2,3B2,4A,5B,6B,7,8,9,10,11A,12A, 12B2, I. BASIC INFORMATION FORM I. Item Details 1 Name of the project Proposed Construction of Residential Development Royal Nesto by K. K. Chandrasekar, Krishna Kishor, B. Paranthaman Sethupathi, Paulvannan,

More information

JAI MAA SHARDA STONE CRUSHING

JAI MAA SHARDA STONE CRUSHING JAI MAA SHARDA STONE CRUSHING Prop. Hukum Singh (M.. 9425585252) Near-Pahunadukan Kedarpur Ambikapur, (C.G.) To, The Member Secretary, SLEIAA(State Level Environment Impact Assessment Authority), Ministry

More information

APPENDIX I (See paragraph 6) FORM 1

APPENDIX I (See paragraph 6) FORM 1 APPENDIX I (See paragraph 6) FORM 1 (I) Basic Information S.. Item Details 1. Name of the project Limestone Mine 2. S.. in the schedule S.. 1(a) mining of mineral is 3. Proposed capacity/area/length/tonnage

More information

Annexure-IV. Form-I for seeking clearance for project attracting CRZ notification. At Thengamputhur Village, Tamil Nadu by

Annexure-IV. Form-I for seeking clearance for project attracting CRZ notification. At Thengamputhur Village, Tamil Nadu by Annexure-IV Form-I for seeking clearance for project attracting CRZ notification Basic Information: Name of the Project :- Location or site alternative under consideration: - Construction of Beach Resort

More information

FORM 1. No condition? If yes, please specify. 8. Does it attract the specific. No condition? If yes, please specify. 9. Location Geo Coordinates

FORM 1. No condition? If yes, please specify. 8. Does it attract the specific. No condition? If yes, please specify. 9. Location Geo Coordinates FORM 1 (I) Basic Information Sl.. Item Details 1. Name of the project/s 9.890 ha. of Proposed Colour Granite Mine of Sri S. Senthil Kumar 2. S.. in the schedule Item- 1(a) (Mining of Minerals) 3. Proposed

More information

M/S Overseas Min Tech Consultants, Jaipur 1

M/S Overseas Min Tech Consultants, Jaipur 1 (I) Basic Information: APPENDIX I (See paragraph 6) FORM 1 S.. Item Details 1. Name of Project Proposed Soapstone Mining Project, Khasra 60, 61, 63, Area: 11.1830Hect., Production: 17508 TPA, Near Village:

More information

APPENDIX I. (See Paragraph 6) FORM 1

APPENDIX I. (See Paragraph 6) FORM 1 APPENDIX I (See Paragraph 6) FORM 1 (I) Basic Information Item Details 1 Name of the Project Satva Shiva Gold 2 S. in the Schedule 8(a) 3 Proposed capacity/ area/ length/ tonnage to be handled/ command

More information

Ambey Mahila Swa Sahayata Samuh President. Smt. Tuleshwari Vill- Gangikot Post: Gangikot Teh.- Surajpur Dist: Surajpur (C.G.

Ambey Mahila Swa Sahayata Samuh President. Smt. Tuleshwari Vill- Gangikot Post: Gangikot Teh.- Surajpur Dist: Surajpur (C.G. Ambey Mahila Swa Sahayata Samuh +91-9617439314 President. Smt. Tuleshwari Vill- Gangikot Post: Gangikot Teh.- Surajpur Dist: Surajpur (C.G.) To, The Member Secretary, SLEIAA (State Level Environment Impact

More information

Application for Prior Environmental Clearance (EC)

Application for Prior Environmental Clearance (EC) Application for Prior Environmental Clearance (EC) (See Paragraph 6 tification dated14 th September 2006) as amended to EIA tification, 2006 issued vide S.O. 3067(E) on dt.01.12.2009. Basic Information

More information

Proposed Ordinary Sand Mining Project at Gata No.- 8Ka/195, Village- Ratauli, Tehsil- Laharpur, District- Sitapur, U.P. FORM 1

Proposed Ordinary Sand Mining Project at Gata No.- 8Ka/195, Village- Ratauli, Tehsil- Laharpur, District- Sitapur, U.P. FORM 1 Proposed Ordinary Sand Mining Project at Gata.- 8Ka/195, Village- Ratauli, (I) Basic Information: Sl. Item Details. 1 Name of the project Proposed Ordinary Sand Mining Project in Sharda River at Gata.-

More information

M/s. SURYA ENTERPRISES H.No: , Sri Paradise Apartments, New Andhra Bank Colony, Anantapuramu District

M/s. SURYA ENTERPRISES H.No: , Sri Paradise Apartments, New Andhra Bank Colony, Anantapuramu District Application for Prior Environmental Clearance (Form 1) For Proposed Road Metal / Building Stone/ Robo/Manufacture Sand Mine Over An Extent Of 9.712 Hectares, in Sy.. 743 of Somandepalli Village, Somandepalli

More information

FORM 1. /area/length/tonnage. No condition? If yes, please specify. 8. Does it attract the specific

FORM 1. /area/length/tonnage. No condition? If yes, please specify. 8. Does it attract the specific FORM 1 (I) Basic Information Sl.. Item Details 1. Name of the project/s 6.490 ha. of Proposed Colour Granite Mine of M/s. Alief Exports 2. S.. in the schedule Item- 1(a) (Mining of Minerals) 3. Proposed

More information

APPENDIX I. (See paragraph 6) FORM 1

APPENDIX I. (See paragraph 6) FORM 1 Form-1 & Project Feasibility Report for Mopar Limestone Mine (13.25 hect) APPENDIX I (See paragraph 6) FORM 1 (I) Basic Information Sr. No. Item Details 1. Name of the project Mopar Limestone Mine 2. Sr.

More information

Residential & Commercial Project with PTC Tenements (SRA Scheme) M/S Darshan Developers Pvt. Ltd FORM-1

Residential & Commercial Project with PTC Tenements (SRA Scheme) M/S Darshan Developers Pvt. Ltd FORM-1 FORM-1 (I) Basic Information Item Details. 1 Name of the Project Residential & Commercial Project with PTC Tenements Under SRA Scheme 2 S.. in the Schedule 8 (b) Proposed capacity/area Total plot area:

More information

APPENDIX I. (See paragraph 6) FORM 1

APPENDIX I. (See paragraph 6) FORM 1 APPENDIX I (See paragraph 6) FORM 1 (I) Basic Information Sr. Item Details 1. Name of the project Mopar Limestone Mine 2. Sr. in the Schedule 1-A 3. Proposed capacity/area/length/tonnage to be handles/command

More information

Ms.Thriveni Earthmovers Private Limited HO.22/110,Greenways Roads,Fairlands,Salem,Tamilnadu

Ms.Thriveni Earthmovers Private Limited HO.22/110,Greenways Roads,Fairlands,Salem,Tamilnadu Application for Prior (Environmental Clearance) Transfer of EC- Form 1 For Transfer of EC from Ms.K.M.Altaf Kouser to Ms.Thriveni Earthmovers Private Limited Over an Extent of 4.838 Hectares of Road Metal

More information

Revised FORM - I & PRE-FEASIBILITY REPORT

Revised FORM - I & PRE-FEASIBILITY REPORT Hind Energy & Coal Beneficiaton (India) Ltd. [Change in Technology from Dry to Wet Type of Coal Washery in EC issued by MoEF letter vide no. J-11015/364/2009-IA-II(M) dated 21st May 2014] at Hindadih Village,

More information

FORM 1. Amendment in Environment Clearance Of Redevelopment Project Redevelopment Project

FORM 1. Amendment in Environment Clearance Of Redevelopment Project Redevelopment Project FORM 1 Amendment in Environment Clearance Of Redevelopment Project Redevelopment Project At C.S. 990 situated at 243-G Patthe Bapurao Marg (Falkland Road), at Girgaon, Division D ward, Mumbai 400 004.

More information

Details required for submitting Fresh EC Application. (Category B2 Projects: Mining of Minor Minerals)

Details required for submitting Fresh EC Application. (Category B2 Projects: Mining of Minor Minerals) Details required for submitting Fresh EC Application (Category B2 Projects: Mining of Minor Minerals) 1. Project Sector (Non-Coal Mining) 2. Project Type (New, Expansion, Modernization) If Project Type

More information

FORM-I. Environmental Clearance (EC)

FORM-I. Environmental Clearance (EC) FORM-I Environmental Clearance (EC) FOR M/S. Mahanth mica mines (MICA, QUARTZ & FELDSPAR MINES) Léase Area : 47.01 Acres/ 19.05 Ha Sy.. 140/P, 142, 143/P & 139/3 Kalichedu (V), Sydapuram (M), SPSR Nellore

More information

FORM 1 SRI LAKSHMI GAYATRI HOSPITAL (P) LTD.

FORM 1 SRI LAKSHMI GAYATRI HOSPITAL (P) LTD. FORM 1 (Submitted to Ministry of Environment, Forests & Climate Change) BY SRI LAKSHMI GAYATRI HOSPITAL (P) LTD. Proposed at: SY. NO. 306, BACHUPALLY VILLAGE, QUTHABULLAPUR MANDAL, RANGAREDDY DISTRICT,

More information

APPENDIX I. (See paragraph-6) FORM 1

APPENDIX I. (See paragraph-6) FORM 1 (I) Basic Information APPENDIX I (See paragraph-6) FORM 1. Item Details 1 Name of the Project/s M/s Cane Agro Energy India Limited 2 S.. in the Schedule 5(g) 3 Proposed capacity/area/length/tonnge to be

More information

FORM 1 Riverbed Sand Mining Project

FORM 1 Riverbed Sand Mining Project FORM 1 Riverbed Sand Mining Project At Gata. 117ध, 1306म ( Kuda River) Village: Gujarauliya, Beltikar, Tehsil: Naugarh, District: Siddharthnagar, Submitted by M/s Baburam Construction Address-1769 B-5

More information

Haridarshan Residency ( Row Type House & School Building )

Haridarshan Residency ( Row Type House & School Building ) Survey.. 18, Moje: : Shekhpur, Tal: Kamrej, Dist.: Surat, Gujarat 394 130 FORM 1 AND BASIC INFORMATION FOR OBTAINING ENVIRONMENTAL CLEARANCE FOR NEW PROJECT OF Haridarshan Residency Block. 18, Village:

More information

RATNAAKAR SHELTER LLP

RATNAAKAR SHELTER LLP FORM 1 Slum Rehabilitation Scheme Aventus Heights At C.T.S 1A (pt) of village Deonar, Taluka Kurla, at Plot 49, Survey no.93 (pt.), Road 5/6 Shivaji Nagar, Govandi East, Mumbai- 400 043. By M/s. RATNAAKAR

More information

FOR THE PROPOSED EXPANSION IN BACKWARD INTEGRATION PROJECT FOR

FOR THE PROPOSED EXPANSION IN BACKWARD INTEGRATION PROJECT FOR FOR THE PROPOSED EXPANSION IN BACKWARD INTEGRATION PROJECT FOR MANUFACTURING MAN MADE FIBER (PARTIALLY ORIENTED YARN (POY), FULLY DRAWN YARM (FDY), TEXUTURISED YARN, TWISTED YARN - OTHER THAN RAYON THROUGH

More information

REPORT OF SAND STONE MINING PROJECT (KHATADARI Q.L. No. 178 FOR

REPORT OF SAND STONE MINING PROJECT (KHATADARI Q.L. No. 178 FOR REPORT OF SAND STONE MINING PROJECT (KHATADARI Q.L. No. 178 FOR Near Village Tehsil District State Capacity Lease Area Category of Project Project Cost KANTBARA BIJOLIYA Bhilwara Rajasthan 36561 TPA of

More information

Appendix I. Form 1 BASIC INFORMATION MASONARY STONE MINING PROJECT VILLAGE KOLIYA, TEHSIL DIDWANA, DISTRICT NAGAUR, RAJSTHAN

Appendix I. Form 1 BASIC INFORMATION MASONARY STONE MINING PROJECT VILLAGE KOLIYA, TEHSIL DIDWANA, DISTRICT NAGAUR, RAJSTHAN Appendix I Form 1 BASIC INFORMATION MASONARY STONE MINING PROJECT VILLAGE KOLIYA, TEHSIL DIDWANA, DISTRICT NAGAUR, RAJSTHAN AREA: 1.0 HECT (NON FOREST LAND) ML: 27/1990 ( R ) 53/2009 PROPOSED PRODUCTION

More information

Annexure-IV. Form-I for seeking clearance for project attracting CRZ notification

Annexure-IV. Form-I for seeking clearance for project attracting CRZ notification Annexure-IV Form-I for seeking clearance for project attracting CRZ notification Basic Information: Name of the Project :- Location or site alternative under consideration: - CRZ Clearance for Resort project

More information

FORM 1. "A TREE desh. STOREY" POOJA CRAFTED HOMES PRIVATE LIMITED

FORM 1. A TREE desh. STOREY POOJA CRAFTED HOMES PRIVATE LIMITED FORM 1 (Submitted to SEIAA, Andhra Pradesh) By "A TREE desh. STOREY" POOJA CRAFTED HOMES PRIVATE LIMITED ( complex) NTS no: 143/3, Block no: 7 Revenue Ward. 11, 40-1-119, Patamata Village, Vijayawada (urban)

More information

EXPANSION OF SPORTS INJURY CENTRE AT SAFDARJUNG ENCLAVE, NEW DELHI

EXPANSION OF SPORTS INJURY CENTRE AT SAFDARJUNG ENCLAVE, NEW DELHI Application for Prior Environmental Clearance (EC) FORM 1 (See Paragraph 6 tification dated14 th September 2006) as amended to EIA tification, 2006 issued vide S.O. 3067(E) on dt. 01.12.2009. Basic Information

More information

Renewal of Environmental Clearance for Commercial Complex City Square 2 S. No. in the Schedule 8 (a), Building & Construction project

Renewal of Environmental Clearance for Commercial Complex City Square 2 S. No. in the Schedule 8 (a), Building & Construction project 1 SCOPING 1.1 FORM 1 The scoping for the project has been done based on Form-I, as per EIA tification, dated September 14, 2006 amended as on date. The scoping details are as follows: I. Basic Information

More information

FORM I GROUP HOUSING PROJECT GH-03C, SECTOR-144 NOIDA, UP. For. M/s GULSHAN HOMES AND INFRASTRUCTURE PVT.LTD ENVIRONMENT CONSULTANT

FORM I GROUP HOUSING PROJECT GH-03C, SECTOR-144 NOIDA, UP. For. M/s GULSHAN HOMES AND INFRASTRUCTURE PVT.LTD ENVIRONMENT CONSULTANT GROUP HOUSING PROJECT AT GH-03C, SECTOR-144 NOIDA, UP For M/s GULSHAN HOMES AND INFRASTRUCTURE PVT.LTD ENVIRONMENT CONSULTANT en-vision Enviro Technologies Pvt. Ltd. (NABET/EIA/364/IA-018(Rev. 1) dated

More information

Application for Prior Environmental Clearance (EC) FORM 1

Application for Prior Environmental Clearance (EC) FORM 1 Application for Prior Environmental Clearance (EC) (See Paragraph 6 tification dated14 th September 2006) as amended to EIA tification, 2006 issued vide S.O. 3067(E) on dt. 01.12.2009. Basic Information

More information