1 Buildings Energy Efficiency & Energy Audit Ir Eagle Mo
2 Contents 1) History of HK Energy Audit 2) Energy Audit in Other Contraries 3) Energy Audit Code (EAC) 4) Case Study
3 1) History of HK Energy Audit
4 What Are Energy Audits? Performing an energy audit is a crucial step to assessing and improving energy efficiency. There are many types of energy audits that can be performed at water and wastewater treatment facilities, ranging from general 'walk-through audits' to more comprehensive 'process audits.
5 Enhancement of Energy Efficiency in Buildings Energy Consumption by Sectors in 2009 Hong Kong Energy End-use Data 2011 l Total annual electricity consumption of HK in 2009: about 41.5 billion kwh (equivalent to the consumption by 9 millions of families annually) l About 90% of the electricity consumed by buildings l Enhancement of buildings energy efficiency will be an effective means to reduce energy consumption
6 The Hong Kong Energy Efficiency Registration Scheme for Buildings (HKEERSB) u Launched since 1998 to promote the voluntary compliance with BEC to enhance building energy efficiency u Up to Dec 2011, around 1,300 buildings have been registered u Registered buildings included commercial, industrial and residential buildings u Participation rate of the private sector is very low (only around 30% of the registered buildings)
7 Mandatory Implementation of Building Energy Code (BEC) As voluntary compliance with a higher energy efficiency standard appears not to be forthcoming in Hong Kong and amidst the growing environmental concerns, Government consider it an opportune time to pursue mandatory implantation of the BECs to accompany market In order to combat climate change, mandatory implementation of minimum energy efficiency standard in buildings by legislation has been widely adopted by overseas and Mainland China driven changes The mandatory BEC is formulated with the existing voluntary BEC 2007 Edition as the blueprint
8 Milestone of the Buildings Energy Efficiency Ordinance (BEEO) 21/03/2011 Registration of Registered Energy Assessors (REA) came into operation 11/ / / / / / / / / / / / / /12/2010 BEEO was gazetted 21/09/2012 BEEO will come into full operation
9 Structure of Legislative Framework Buildings Energy Efficiency Ordinance (BEEO) Buildings Energy Efficiency (Fees) Regulation Buildings Energy Efficiency (Registered Energy Assessors) Regulation Energy Audit Code (EAC) Building Energy Code (BEC) Code of Practice
10 Control Regimes 1) Newly constructed buildings will be required to comply with the minimum energy efficiency standards and requirements as specified in BEC under BEEO 2) Existing buildings will be required to comply with BEC only when major retrofitting works are carried out 3) Commercial buildings and commercial portions of composite buildings will be required to carry out energy audits in accordance with the technical requirements as specified in EAC under BEEO
11 Control Regimes (cont d) Different regulatory mechanisms for newly constructed building after the commencement of the legislation and existing building before the commencement of the legislation Newly constructed building after the commencement of the legislation Buildings having obtained the consent to the commencement of building works for superstructure construction from Building Authority after the legislation comes into full operation (i.e. 21 Sep 2012) Existing building before the commencement of the legislation Buildings that have obtained the consent on or before the legislation comes into full operation (i.e. 21 Sep 2012) *Remarks: The abov e two terms are for publicity purpose only and do not appear in BEEO.
12 Energy Audit Ø Only applicable to central BS installations of commercial buildings and commercial portions of composite buildings The owner of a building is required to engage a REA to conduct Energy Audit every 10 years The owner is required to obtain an Energy Audit Form and an energy audit report from the REA The REA is required to submit a copy of Energy Audit Form and the energy audit report to EMSD for record The owner is required to exhibit the valid Energy Audit Form in a conspicuous position at the main entrance of the building
13 2) Energy Audit in Other Contraries
14 Energy Audit in US The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) refers to benchmarking as a preliminary energy use analysis; this process involves collecting facility energy data, reviewing energy bills, and comparing the facility's energy consumption with similarly-sized facilities using similar processes. EPA s Energy Star's Portfolio Manager is a free, on-line benchmarking tool. EPA recommends all facilities use Portfolio Manager or another benchmarking tool prior to completing a walk-through or detailed process audit.
15 Energy Audit in US Walk-through (also called ASHRAE Level 1) audits provide a first cut assessment of energy savings; they re especially valuable to small utilities with simple production and distribution systems, and facilities that have never received an energy audit. While walkthrough audits lack a detailed analysis of potential energy efficiency measures (and only sometimes include rough pay-back period estimates), they reliably include relatively simple and immediately affordable recommendations such as changes in operation timing (based on utility rate schedules), and upgrades to lighting, heating, ventilating and air conditioning (HVAC), and pumping equipment. For a small facility, a walk-through audit can be completed in 2-6 hours by someone familiar with the system. A number of entitles have provided Do It Yourself guidance to assist facilities in conducting their own walk-through audits.
16 Energy Audit in US Detailed process audits (also called Level 2 or, if more refined Level 3 ASHRAE audits) require a more in-depth conversation between the facility and professional auditors experienced in water and wastewater systems. Detailed process audits are the most costeffective for mid-size and large facilities that lack in-house time to investigate energy efficiency opportunities, and that have not recently received an energy audit. Detailed process audits often involve equipment field tests, inventorying equipment energy performance data, creating energy profiles for equipment and systems, discussing potential O&M changes, and evaluating potential energy efficiency and renewable energy projects. Detailed process audits provide comprehensive information on the pay-back periods associated with the recommended measures.
17 3) Energy Audit Code (EAC) Code of Practice for Building Energy Audit
18 18 Briefing on Energy Audit -The Buildings Energy Efficiency Ordinance Cap 610 (the Ordinance) which is to come into full operation from 21 September 2012 onward. BUILDING THAT REQUIRE ENERGY AUDIT: 1.Commercial Building. 2.A portion of a composite building that is commercial use. 特立美環保及能源管理有限公司
19 19 Briefing on Energy Audit SCHEDULE OF THE FIRST ENERGY AUDIT: Date of issue of occupation approval in respect of the building On or after 1 January 1988 Period within which the first energy audit must be carried out 12 months from the commencement of Part 4 of this Ordinance After 1 January 1978 but before 1 January 24 months from the commencement of Part of this Ordinance After 31 December 1969 but before 31 December months from the commencement of Part 4 of this Ordinance On or before 31 December months from the commencement of Part 4 of this Ordinance 特立美環保及能源管理有限公司
20 EAC Requirements Key Steps 1. Collection of information 2. Review of energy 3. Identification of EMO 4. Cost benefit analysis of EMO 5. Recommendations 6. Compiling energy audit report
21 21 Scope - Energy audit carried out for the central building services installations. 4 Key types of central building services installations i) Air-conditioning installation ii) Electrical installation iii) Lighting installation iv) Lift and Escalator installation 特立美環保及能源管理有限公司
22 22 Scope - Step 1: Data Collection and Review ü Information on building operation & technical characteristic of various energy consumption were collected. ü Equipment type ü Quantity ü Power consumption ü Running schedule 特立美環保及能源管理有限公司
23 23 Scope - Step 1: Data Collection and Review (cont ) ü ü ü ü General Building Plan Occupancy Permit GFA of the building Retail Area 特立美環保及能源管理有限公司
24 Scope - Step 1: Data Collection and Review (cont ) Owner of building Owner of Building Company: Address: Tel: Fax: Representative of Owner of Building Company: Contact Person: (Eng) (Chinese) Position in the company: Address: Tel: Fax:
25 25 Scope - Step 2: Review of Energy The monthly and annual energy consumption of the building will be calculated ü Site survey will be conducted with E&M plant operators and engineers. - Confirm the equipment type - Confirm the equipment quantity - Confirm the equipment power consumption 特立美環保及能源管理有限公司
26 26 Scope Step 3: Identification of EMO Example: Replacing existing inefficient electrical equipment Replacing lower COP chillers Install occupancy sensors 特立美環保及能源管理有限公司
27 27 Scope - Step 4: Cost benefit analysis of EMO - Cost benefit and payback period will be provided if major BS equipment are being recommended to replace. 特立美環保及能源管理有限公司
28 28 Scope - Step 5: Recommendation ü Recommendation for the energy improvement work in the next few years will be provided to the owner for their consideration. 特立美環保及能源管理有限公司
29 29 Scope - Step 6: Compiling Energy Audit Report ü Energy audit report include: building information, findings, scope of audit, description of operating characteristics, recommendations and EMO. Appendix (calculation summary) 特立美環保及能源管理有限公司
30 EAC Requirements Energy audit report Energy utilization index (EUI) (MJ/m/ annum) Energy audit form (exhibit at building main entrance) Energy management opportunities (EMO) Implementation not mandatory
31 4) Case Study
32 Energy Audit Example Chiller System Identify Energy Consumption and its Efficiency AHU / PAU System 特立美環保及能源管理有限公司
33 Energy Audit Example 2 Lighting System Identification Electrical System
34 Elevation System Identify Power and Efficiency Energy Audit Example 3
35 Required information - Energy Bills Energy Bill in Excel format for 36 months
36 Required information Equipment Schedule (1) Equipment schedule with type, quantity, rating and power consumption
37 Required information Equipment Schedule (2) MVAC Chillers, chiller pump, AHU/PAU, FCU, exhaust fan Lighting Schedule Lift and Escalator
38 Required information - Operation Schedule MVAC equipment Lift and Escalator Lighting
39 Required information - Site Layout Layout in PDF or CAD format with dimension GBP
40 Required information -Administrative Information (1) GFA of the building Retail Area
41 Required information -Administrative Information (2) Occupancy Permit
42 Required information -Administrative Information (3) Owner of building Owner of Building Company: Address: Tel: Fax: Representative of Owner of Building Company: Contact Person: (Eng) (Chinese) Position in the company: Address: Tel: Fax:
43 END My Contact eaglemo@telemaxeem.com Tel :
Buildings Energy Efficiency Ordinance & Building Energy Code 2015 (BEEO & BEC 2015) Nov. 2016
Buildings Energy Efficiency Ordinance & Building Energy Code 2015 (BEEO & BEC 2015) Nov. 2016 1 Topics 1. BEEO 2. BEC 2015 a. Lighting Installation b. Electrical Installation c. Air-conditioning Installation
More informationLow-Carbon Building Management
物業管理行業的環保政策 Low-Carbon Building Management 鄺正煒行政總裁 Ir Walter Au FHKIE, RPE, REA, BEAMPro, FIEAust, CEng, MIET Carbon Auditor Professional 1 1. Hong Kong s Carbon Footprint In 2012, Hong Kong s total Carbon
More informationand Conservation in Hong Kong
Promotion of Energy Efficiency and Conservation in Hong Kong - Experience in Government Departments Presentation to Hong Kong Institute of Facility Management Limited by Ir UY Tat-ping Assistant Director,
More informationNEW Energy Efficiency Promotion Programme
NEW Energy Efficiency Promotion Programme 19 th Nov 2008 New Programme for Promoting Energy Efficiency Promote Energy Efficiency & Environmental Performance in addition to providing adequate & reliable
More informationInsight into Energy Savings at Your WWTP: The Good, the Bad, and the Ugly
Fishbeck, Thompson, Carr & Huber, Inc. Insight into Energy Savings at Your WWTP: The Good, the Bad, and the Ugly John Eberly, P.E. and Erin Szczegielniak, P.E. Fishbeck, Thompson, Carr and Huber, Inc.
More informationOperation and maintenance to improve energy efficiency and sustainability of existing buildings
Green Buildings: Better Quality of Life, 11 June 2010 (Fri) Session 4: Improvement of Sustainability Operation and maintenance to improve energy efficiency and sustainability of existing buildings HKU
More informationKnowledge Based Energy Management
Knowledge Based Energy Management Ir Cary CHAN Executive Director Hong Kong Green Building Council 4 th May 2016 1 How Efficient is Our Plant? Efficiency = Output Input Saving Estimation How much can you
More informationZero energy highrise. Dream Comes True? Zero Carbon Building Conference 2015
Zero Carbon Building Conference 2015 Zero energy highrise building Dream Comes True? Ir Conrad WONG, BBS, JP Chairman, Hong Kong Green Building Council 15 October 2015 1 An interview by RTHK: My Dream,
More informationIncentives & Resources for Small Customers. Adam B. Fields I Leidos
Incentives & Resources for Small Customers Adam B. Fields I Leidos Project Incentives Scott's Estimated Savings Energy-efficient lighting $19,339.91 $16,271.50 per year, 232,450 kwh Contents» Resources
More informationADOPTION OF WATER-COOLED AIR CONDITIONING SYSTEMS FOR TERRITORY-WIDE ENERGY IMPROVEMENT
ADOPTION OF WATER-COOLED AIR CONDITIONING SYSTEMS FOR TERRITORY-WIDE ENERGY IMPROVEMENT Summary Ir S.K. HO, Ir L.S. TAM and Ir S.K. LO Energy Efficiency Office, Electrical and Mechanical Services Department
More informationDTE Energy Commercial & Industrial Energy Optimization Program. Trade Ally Meeting. Guardian Plumbing & Heating January 20, 2011
DTE Energy Commercial & Industrial Energy Optimization Program Trade Ally Meeting Guardian Plumbing & Heating January 20, 2011 Agenda Introduction DTE Energy Your Energy Savings Program Overview 2011 Program
More informationEnergy Efficiency in Multi-Tenant Office Buildings
Energy Efficiency in Multi-Tenant Office Buildings Presented by David Herman, PE, LEED AP Principal, EnerG Associates, LLC 3/10/2015 1 Learning Objectives 1. List the principal sources and uses of energy
More informationENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING
ENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING Brittany Hanam 1, Lorne Ricketts 2, Andrew Pape-Salmon 3 ABSTRACT The National Institute of Building Sciences estimates that over 70% of the
More informationMETHODOLOGY The process starts with a collection of available information, continued by an audit in loco, it is
Seventh International IBPSA Conference Rio de Janeiro, Brazil August 13-15, 2001 METHODOLOGY FOR BUILDING MODELLING AND CALIBRATION FOR WARM CLIMATES A. Pedrini* and R. Lamberts** *Dept. of Architecture,
More informationGETTING TO EFFICIENT BUILDINGS
GETTING TO EFFICIENT BUILDINGS Andy Robinson, SEDAC SEDAC + EPA Moraine Valley Community College Dec 2016 SEDAC GOALS FOR OUR CLIENTS: Save energy dollars Identify efficient equipment upgrades Identify
More informationRetro-Commissioning in Hospitals
Retro-Commissioning in Hospitals American Society of Healthcare Engineering () Introduction Elements of the Health Facility Retro-Cx Process Retro-Cx Case Studies Hospital Hospital Oklahoma Heart Hospital
More informationEnhancing Business Competitiveness Through Carbon Audit
Enhancing Business Competitiveness Through Carbon Audit Tsang Kam Lam, JP General Manager Environmental Management Division Hong Kong Productivity Council 29 October 2012 Business Operation and Carbon
More informationDo-It-Yourself Energy Audit. Bob Furgeson, PE CEM CBCP GBE CEA Shive-Hattery Architects+Engineering
Do-It-Yourself Energy Audit Bob Furgeson, PE CEM CBCP GBE CEA Shive-Hattery Architects+Engineering Agenda» Basic Terminology» Background» Benchmarking» Audit Types/ASHRAE Standard» Building Audit Systems
More informationInternational Institute for Sustainable Laboratories CONCEPT PLAN
LINDSEY KAYMAN CONSULTING International Institute for Sustainable Laboratories CONCEPT PLAN A Sustainable Laboratory Performance Improvement Program Drafted Under Contract To Lindsey Kayman, CIH, LEED
More informationTHE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:
ORDINANCE NO. 18 4 S 7 4 An ordinance adding Division 97 to Article I, Chapter IX and amending Division 4 of Article 8, Chapter IX of the Los Angeles Municipal Code to establish the City of Los Angeles
More informationSouth Carolina Society for Hospital Engineers
South Carolina Society for Hospital Engineers Selecting Energy Partners: Criteria & Pitfalls and the Top 10 Ways to Reduce Energy in a Hospital Presented by Jon Dierking, PE, CEM, LEED AP Director of Energy
More informationA Building Commissioning Overview. Presented by: Goetting & Associates Commissioning
A Building Commissioning Overview Presented by: Goetting & Associates Commissioning www.goettingcx.com What is the Definition of Commissioning? Building Commissioning is a Quality Assurance Process of
More informationBAGUIO GREEN GROUP LIMITED 碧瑤綠色集團有限公司. Terms of reference of Audit Committee ( Committee )
Adoption Date : 24 April 2014 Membership BAGUIO GREEN GROUP LIMITED 碧瑤綠色集團有限公司 (Incorporated in Cayman Islands with limited liability) (Stock Code: 1397) ( Company ) Terms of reference of Audit Committee
More informationBuilding a Winning Green Building Strategy
Building a Winning Green Building Strategy Successful Policies for Government, Industry and the Environment By Helen Carruthers, BSc, LEED AP; John Madden, BA, Dipl (Urban Design), LEED AP NC + ND; Veronica
More informationHoneywell Bundled Energy Services. Address All Your Energy Management Issues With One Affordable Solution
Honeywell Bundled Energy Services Address All Your Energy Management Issues With One Affordable Solution The Challenge of Total Energy Management. Answered. Facility managers and directors are focused
More informationEnergy Efficiency Planning. June 30, 2009
Energy Efficiency Planning at Genzyme June 30, 2009 Genzyme - A Global Corporation >11,000 employees worldwide Helping patients in 100 countries 17 manufacturing sites 9 genetic testing lab sites 19 major
More informationRequest for Proposals Town of Plymouth, New Hampshire
1. General Information Request for Proposals Town of Plymouth, New Hampshire Building Energy Audits The Town of Plymouth is seeking bids for qualified individuals or firms to provide six (6) Building Energy
More informationAvailable online at ScienceDirect. Procedia Engineering 121 (2015 )
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 121 (2015 ) 317 324 The 9th International Symposium on Heating, Ventilation and Air Conditioning (ISHVAC) and the 3rd International
More informationSeminar 29. Urban Scale Building Energy Modeling, Part 5
Seminar 29 Yixing Chen, ASHRAE Member Lawrence Berkeley National Laboratory yixingchen@lbl.gov Urban Scale Building Energy Modeling, Part 5 Retrofitting District Scale Buildings to Cut Energy Use By 50%:
More informationSingapore Energy efficiency report
Singapore Energy efficiency report Objective: 3% reduction in energy intensity by 23 compared with Overview - (%/year) Primary intensity (EU=1)¹ 63 ++ -4.9% ++ CO 2 intensity (EU=1) 68 ++ -3.9% ++ CO 2
More informationEnergy Smart Program Guide
NB Power Commercial Buildings Energy Efficiency Retrofit Program Version 5.3 March 2015 www.nbpower.com TABLE OF CONTENTS 1.0 PROGRAM INTRODUCTION... 1 2.0 ELIGIBILITY AND REQUIREMENTS... 1 2.1 ELIGIBLE
More informationDCAS Energy Management. August 15, 2014 Ellen Ryan & Mike Dipple
DCAS Energy Management August 15, 2014 Ellen Ryan & Mike Dipple DCAS Energy Management Mission DCAS Energy Management (DEM) serves as the hub for City government s energy management. DEM provides energy
More informationTexas Industries of the Future November 20, 2013
For Texas Industries of the Future November 20, 2013 Bob Bessette, President Council of Industrial Boiler Owners CIBO is dedicated to ensuring that non-utility industrial, commercial and institutional
More informationNew Jersey Board of Public Utilities Clean Energy Incentive Program
New Jersey Board of Public Utilities Clean Energy Incentive Program Passaic County Division of Economic Development Gary E Finger Business Ombudsman June 15, 2015 Program Goals Save energy and lower operating
More informationLIBRARY ENERGY WALK- THROUGH. Andy Robinson, Training and Education, SEDAC
LIBRARY ENERGY WALK- THROUGH Andy Robinson, Training and Education, SEDAC ILLINOIS ENERGY NOW University of Illinois 360 Energy Group 2 WHAT WE DO SEDAC Free Services Outreach and Training Energy Assistance
More informationAudit of City Cleaning Services Part 1: Opportunities to Control Costs, Improve Productivity and Enhance Quality of Cleaning Services
AUDITOR GENERAL S REPORT ACTION REQUIRED Audit of City Cleaning Services Part 1: Opportunities to Control Costs, Improve Productivity and Enhance Quality of Cleaning Services Date: June 14, 2016 To: From:
More informationBest Practice of QR Code Application in China Energy Label
2017/SOM3/SCSC/WKSP2/008 Best Practice of QR Code Application in China Energy Label Submitted by: China Workshop on Facilitating Trade in ICT Products Through Encouragement of Electronic Labeling Best
More informationInformation Session for Authorized Employers ("AE") and Authorized Supervisors ("AS") 17 November 2017
Information Session for Authorized Employers ("AE") and Authorized Supervisors ("AS") 17 November 2017 Agenda Overview of the Practical Experience Framework Roles and Responsibilities of AE/ AS AE/ AS
More informationHigh Technology Energy Savings Guide
High Technology Energy Savings Guide The high-tech industry is a crucial and dynamic part of Oregon s economy that is expected to grow faster than other industries over the next decade. Working in a highly
More informationEnergy Audit Baseline & Economic Analysis. Mr. Jirayut Charoenchatchai Manager,Energy Efficiency Div. Bright Management Consulting Co.,Ltd.
Energy Audit Baseline & Economic Analysis Mr. Jirayut Charoenchatchai Manager,Energy Efficiency Div. Bright Management Consulting Co.,Ltd. Page 1 Content Energy Audit Approach Criteria for Data Collection
More informationProgram Guide. NB Power Commercial Buildings Retrofit Program. Version 5.5 August 2016
NB Power Commercial Buildings Retrofit Program Version 5.5 August 2016 www.nbpower.com TABLE OF CONTENTS 1.0 PROGRAM INTRODUCTION... 1 2.0 ELIGIBILITY AND REQUIREMENTS... 1 2.1 ELIGIBLE BUILDING TYPES...
More informationOverview of Work Point Energy Efficiency Retrofit Project (Using an ESCO Facilitator) 17 November Christopher Seeley
Overview of Work Point Energy Efficiency Retrofit Project (Using an ESCO Facilitator) 17 November 2015 Christopher Seeley Facilitator Background Energy Efficiency Building Retrofit Program - Clinton Foundation
More informationEnergy Reduction Strategy Through 2020
Through 2020 Revised: August 2017 Executive Summary Auburn University is a land, sea and space grant university established in 1856. The university consists of 11,629,000 square feet on 1,840 acres and
More informationBB&E GREENHOUSE GAS EMISSIONS INVENTORY. Prepared For: General Services Administration (GSA) Joint Base Andrews, Maryland.
BB&E GREENHOUSE GAS EMISSIONS INVENTORY Prepared For: General Services Administration (GSA) Joint Base Andrews, Maryland Prepared By: BB&E, Inc. July 2014 This Greenhouse Gas (GHG) Emissions Inventory
More informationTerms and Conditions for using BEA Credit Card in Digital Wallet
Terms and Conditions for using BEA Credit Card in Digital Wallet These Terms and Conditions for using your BEA Credit Card in Digital Wallet ("Terms and Conditions") apply when you choose to add a BEA
More informationT-24 energy and LEED energy modeling credits: Understanding the similarities and differences
T-24 energy and LEED energy modeling credits: Understanding the similarities and differences Kevin P. Gilleran 1 Introduction We have 40 minutes to take a quick look at two similar but not identical processes
More informationENERGY AUDIT. Prepared For: Wayne Public School District. John D. Maso, Director of Facilities Mgmt. Office of Building Services
Prepared For: Wayne Public School District John D. Maso, Director of Facilities Mgmt. Office of Building Services ENERGY AUDIT Prepared By: Dome-Tech, Inc. Prepared Under the Guidelines of the State of
More informationENERGY MANAGEMENT THROUGH BUILDING RETROFITTING: PROSPECTS FOR KSA. Dr. M. Asif. King Fahd University of Petroleum & Minerals, KSA
ENERGY MANAGEMENT THROUGH BUILDING RETROFITTING: PROSPECTS FOR KSA Dr. M. Asif King Fahd University of Petroleum & Minerals, KSA PRESENTATION OUTLINES 2 Retrofitting for a sustainable built environment
More informationEnergy Efficiency of Office Appliances
Energy Efficiency of Office Appliances for Low-carbon Office Operations Programme (LOOP) seminar Presented by: Tommy Cheung Carbon and Energy Management Solutions Date: 21 Mar, 2013 These materials are
More informationPROJECT CLEAN AIR CHARTER PHASE II
PROJECT CLEAN AIR CHARTER PHASE II Pilot Certification Scheme for Clean Air Charter Final Report For Neonlite Electronic & Lighting (HK) Ltd Prepared by May 2008 1. INTRODUCTION Neonlite Electronic & Lighting
More informationConservation & Demand Management (CDM) Program Update
Conservation & Demand Management (CDM) Program Update Mike Mulqueen Lead - CDM Business Development Housing Services Energy Forum October 27, 2015 Agenda CDM 2016 Update Current Programs New Pilot Programs
More informationThe White Certificate Scheme in New South Wales, Australia
The White Certificate Scheme in New South Wales, Australia Dr David Crossley Managing Director Energy Futures Australia Pty Ltd IEA Demand Side Management Programme Task 14 Workshop on White Certificates
More informationTHE ASHRAE BUILDING ENERGY LABELING PROGRAM
THE ASHRAE BUILDING ENERGY LABELING PROGRAM William P. Bahnfleth, PhD, PE, FASHRAE, FASME The Pennsylvania State University ASHRAE Illinois Chapter December 11, 2012 Outline Background ASHRAE s Labeling
More informationCentralizing Your Energy Supply Spend
HAPPY NEW YEAR! The entire team at Siemens Retail & Commercial Systems wishes you all the best for a prosperous 2016. If saving more money is on your list of resolutions, then contact us. We d love to
More informationEnergy & Green Building strategies
Energy & Green Building strategies Establishing a PACE financing Program 2018 Targets 2012 Baselines Reduce air pollution 25% from 2007 5.8M tons of CO2e Develop new incentives and rebates for building
More informationEstablishing a Baseline, Energy Audits and Energy Star s Portfolio Manager
Establishing a Baseline, Energy Audits and Energy Star s Portfolio Manager Glenn Barnes Environmental Finance Center University of North Carolina at Chapel Hill 919-962-2789 glennbarnes@sog.unc.edu Energy
More informationStrategic Plan and Proposed FY18 Program Changes
Strategic Plan and Proposed FY18 Program Changes EE Committee Meeting April 11, 2017 Presented by TRC Team 1 2 Themes from Strategic Plan Stakeholder Process Make it easier to participate Provide more
More informationHow can the next Chief Executive build on Government s Climate Action Plan and encourage renewable energy uptake?
Michel Roggo / WWF-Canon How can the next Chief Executive build on Government s Climate Action Plan 2030+ and encourage renewable energy uptake? Gavin Edwards Director, Conservation WWF-Hong Kong 24 February
More informationEvaluation of Energy Savings of the New Chinese Commercial Building Energy Standard
Evaluation of Energy Savings of the New Chinese Commercial Building Energy Standard Wei Feng, Ke Huang, Mark Levine and Nan Zhou, Lawrence Berkeley National Laboratory Shicong Zhang, Lawrence Berkeley
More informationEmbodied Carbon of Concrete / Steel - Building Structures using Nonlinear Optimization
Dept. of Civil and Environmental Engineering Material Science and Technology in Engineering Conference Frontiers of Sustainable Materials Embodied Carbon of Concrete / Steel - Building Structures using
More informationAmeren Illinois Energy Efficiency Programs and Incentives. Helping public sector buildings and communities save energy and money.
Ameren Illinois Energy Efficiency Programs and Incentives Helping public sector buildings and communities save energy and money. 1 Why Energy Efficiency? Save money Reduce environmental impact Increase
More informationPromoting Deep Energy Retrofits of Large Commercial Buildings To Reduce Nitrogen Oxide Emissions In the Ozone Transport Region
Promoting Deep Energy Retrofits of Large Commercial Buildings To Reduce Nitrogen Oxide Emissions In the Ozone Transport Region Ozone Transport Commission Energy Efficiency Workgroup Status Report 08-15-12
More informationPremium Sample Reports
Premium Sample Reports Under the WegoWise Premium subscription, we deliver the following reports in pdf format to present actionable information and answers to common questions property managers and owners
More informationCentre for Addiction and Mental Health Queen Street Campus Energy Conservation and Demand Management Plan
Centre for Addiction and Mental Health Queen Street Campus Energy Conservation and Demand Management Plan In Transition to Sustainable Infrastructure The Centre for Addiction and Mental Health is in the
More informationComplying with the Minimum Energy Efficiency Standards (MEES)
Complying with the Minimum Energy Efficiency Standards (MEES) Advantages of using DSM software to calculate the EPC Rating Introduction The Minimum Energy Efficiency Standards (MEES) for commercially rented
More informationGreat Ocean Rd Ice Creamery
Great Ocean Rd Ice Creamery BCA Section J - JV3 Compliance Report Revision: 01 Job No: 2171 Date: 7 July 2015 ADP Consulting Pty Ltd Level 10, 10 Queens Rd, Melbourne Vic 3004 www.adpconsulting.com.au
More informationThe Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma
LEED Green Building Certification The purpose of the LEED Green Building Rating is to provide a national standard that aims to improve environmental, health and economic performance of buildings using
More informationThe Energy Program Tricycle: Which Wheel Should You Put in Front?
The Energy Program Tricycle: Which Wheel Should You Put in Front? Laurie Gilmer, P.E., CFM, SFP, LEED AP, CxA Conrad Kelso, P.E., CEM Meet our Presenters Laurie Gilmer, P.E., CFM, SFP, LEED AP, CxA Vice
More informationENERGY CALCULATOR & MODELLING PROTOCOL
Green Star SA Retail Centre v1 ENERGY CALCULATOR & MODELLING PROTOCOL GUIDE VERSION 1.1 Last Update: 17 June 2010 1 Executive Summary The Green Star SA Retail Centre v1 rating tool has been developed to
More informationExecutive Summary Energy Conservation and Demand Management (ECDM) Plan
Appendix A Executive Summary Energy Conservation and Demand Management (ECDM) Plan The City of Toronto has been committed to reduction of greenhouse gas emissions, generation of renewable energy and improvement
More informationEnergy Efficiency Solutions for Multifamily Housing. Clark Energy Group LLC
Energy Efficiency Solutions for Multifamily Housing Clark Energy Group LLC 1 Agenda About Clark Energy Group Energy Service Company (ESCO) Overview ESCO Services Utility Rate Forecasts Making the Decision
More informationSustainable Building Operations & Upgrades
Sustainable Building Operations & Upgrades LEED for Existing Buildings 2010 Energy / Facilities Connections Conference Brightworks & Glumac Eric Baxter and Todd McGuire 12 May, 2010 The Value Proposition
More informationCommercial & Industrial Conservation and Energy Efficiency Programs
St. Louis Green Business Challenge Energy Efficiency Seminar May 30, 2013 Commercial & Industrial Conservation and Energy Efficiency Programs Jim Travis Laclede Gas Company About Laclede Gas Company at
More informationEnergy Modeling Applications for Existing Buildings
Energy Modeling Applications for Existing Buildings Presented by: Clark Denson PE, CEM, BEMP, LEED AP BD+C 4/27/12 Learning Objectives 1. List available methods and tools for energy modeling 2. Explain
More informationNo Cost/Low Cost Energy
No Cost/Low Cost Energy Saving Strategies Randall D. Manteufel University of Texas at San Antonio Energy Efficiency in Local Government andschool Districts in the Border Region No Cost/Low Cost Relatively
More informationNew Jersey s 2017 Clean Energy Program
New Jersey s 2017 Clean Energy Program Opportunities for Commercial, Industrial and Institutional Buildings Arif Welcher NJCEP BACKGROUND Administered by the New Jersey Board of Public Utilities Funded
More informationLow-Hanging Fruit Simple Steps Toward Energy Effective Building Operations
Low-Hanging Fruit Simple Steps Toward Energy Effective Building Operations Roger Ebbage Northwest Water / Energy Education Institute Lane Community College May 7-9 Enzian Inn - Leavenworth, Washington
More informationFinance for Environmental Upgrade Agreements
Finance for Environmental Upgrade Agreements Up to a total of $80 million boost for retrofitting commercial buildings SUMMARY Environmental Upgrade Agreement (EUA) finance of up to a total of $80 million
More informationEconomic Development and Construction Industry in China
Economic Development and Construction Industry in China CAPEC-CESA Seminar Dec. 13, 2013 Economic Development 18 th CPC Congress, milestone in China s economic and social development, blueprint for development
More informationThe Design of a New Programme to Increase the Energy Efficiency in Commercial and Public Companies
The Design of a New Programme to Increase the Energy Efficiency in Commercial and Public Companies Vasco Janeiro, Eurelectric Paolo Bertoldi, European Commission DG JRC Vincent Berrutto, European Commission
More informationEfficientHealthcare A Perspective on Energy Efficiency in the Healthcare Sector
EfficientHealthcare A Perspective on Energy Efficiency in the Healthcare Sector Background Indian healthcare sector is one of the largest and fastest growing sectors. By 2020, it is expected to become
More informationCustom Application 2018 Retrofit Program
The Retrofit Program is designed for Commercial and Industrial (C&I) customers to help replace aging and inefficient equipment and systems with more energy efficient technologies. Tailored to a customer's
More informationThe Certified Energy Manager (CEM ) Program for Professional Certification
The Certified Energy Manager (CEM ) Program for Professional Certification Date : 5-8 December, 2017 Time : 9:00 am to 5:30 pm Exam : 1:30 pm to 5:30 pm (Last Day) Venue : To be advised Course Code : CEM/17/HK
More informationBuilding Energy Analysis for a Multi-Family Residential Building (Multi V III VRF Heat-Pump System)
Building Energy Analysis for a Multi-Family Residential Building (Multi V III VRF Heat-Pump System) Residential-Building Energy-Modeling Engineering Study VRF-ES-BH-001-US 012E03 Executive Summary Contents
More informationPSE Efficiency Programs Sheryl Anayas
PSE Efficiency Programs Sheryl Anayas Program Manager May 6, 2014 Safety Moment Call 811 before you dig It s the LAW and it s FREE! A service that will mark the location of underground utility lines. Use
More informationEffective Energy Management
Effective Energy Management Steve Robison Senior Technical Director American Foundry Society PROFIT How can you increase your total operating profit? Increased sales Reduced costs Both have the same effect.
More informationGuideline HVAC&R Technical Requirements for The Commissioning Process
Guideline 1-2007 HVAC&R Technical Requirements for The Commissioning Process Charles E Dorgan, PE, PhD University of Wisconsin - Madison Synopsis The commissioning process for delivering quality new construction
More informationWater and Wastewater Treatment Energy Savings Guide
Water and Wastewater Treatment Energy Savings Guide Oregon water and wastewater treatment plants face challenges of growing hydraulic demand, rising operating costs, increased regulatory requirements and
More informationEnergy Efficiency Initiatives in India. B. P. Pandey Additional Secretary Ministry of Power
Energy Efficiency Initiatives in India B. P. Pandey Additional Secretary Ministry of Power kgoe/2005 US$ (PPP) Energy Intensity Continues To Decline 0.35 Energy Intensity 0.3 0.25 0.2 0.15 0.1 0.05 0 China
More informationELIAS BOUDINOT ELEMENTARY SCHOOL Pearl and Ellis Street, Burlington NJ 08016
BURLINGTON CITY PUBLIC SCHOOLS ELIAS BOUDINOT ELEMENTARY SCHOOL Pearl and Ellis Street, Burlington NJ 08016 LOCAL GOVERNMENT ENERGY AUDIT PROGRAM FOR NEW JERSEY BOARD OF PUBLIC UTILITIES September 2014
More informationversion 1 / 96 R Green Stars Hotel Environmental Management System
Environmental Management Manual for Hotels in Hong Kong version 1 / 96 R Green Stars Hotel Environmental Management System 2002 Acknowledgements: This document is a revised version of the manual published
More informationTokyo, 29 th October Ir. Rana Yusuf Nasir. Past President ASHRAE Indonesia Chapter Core Founder of GBCI
Tokyo, 29 th October 2015 Ir. Rana Yusuf Nasir Past President ASHRAE Indonesia Chapter 2009-2010 Core Founder of GBCI NATIONAL COMMITMENT TO REDUCE GHG EMISSION Global Warming and Climate Change has been
More informationEnergy Management System ISO By: Eng. Fadi Al Shihabi Senior Manager Ernst & Young BEP, CEM,CRM
Energy Management System ISO 50001-2011 By: Eng. Fadi Al Shihabi Senior Manager Ernst & Young BEP, CEM,CRM Page 2 Energy Futures Market Energy Efficiency Certificate Energy Subsidy Renewable Energy Certificate
More informationTechnical Seminar on Building and District Energy
3 Mandatory CPD hours for BEAM Pro / BEAM Affiliate Technical Seminar on Building and District Energy Date : 7 April 2017 (Friday) Time : 2:15pm - 5:15pm (Registration will start at 2:00pm) Venue : Conference
More informationIncorporating Uncertainty Analysis into a Building Retrofit Analysis Using OpenStudio and EnergyPlus
Incorporating Uncertainty Analysis into a Building Retrofit Analysis Using OpenStudio and EnergyPlus Hayes Zirnhelt 1, Ellen Franconi 1, Nicholas Long 2, Brian Ball 2 1 Rocky Mountain Institute 2 National
More informationESCO EXPERIENCE IN JAMAICA
EU/GOJ DEVELOPING AN ENERGY SERVICES COMPANY (ESCO) INDUSTRY IN JAMAICA STAKEHOLDER CONSULTATION JULY 2ND 2013 ESCO EXPERIENCE IN JAMAICA EATON HAUGHTON, P.E. CARIBBEAN ESCO LTD. email: ehaughton@caribbeanescoltd.com
More informationMount Sinai Main Hospital Energy Conservation and Demand Management Plan
Mount Sinai Main Hospital Energy Conservation and Demand Management Plan Leadership in Energy Efficiency Already at the top quartile of energy performance, Mount Sinai is working towards becoming one of
More informationELMER ELEMENTARY SCHOOL 207 Front Street, Elmer NJ 08318
PITTSGROVE TOWNSHIP SCHOOL DISTRICT ELMER ELEMENTARY SCHOOL 207 Front Street, Elmer NJ 08318 LOCAL GOVERNMENT ENERGY AUDIT PROGRAM FOR NEW JERSEY BOARD OF PUBLIC UTILITIES June 2014 Prepared by: 6 Campus
More informationAsset Energy Calculator Guidance
Asset Energy Calculator Guidance Introduction This section has been produced to give BREEAM In-Use assessors further guidance on the workings of the asset energy calculator so it is clear how any improvements
More information