Fire Protection Valves

Size: px
Start display at page:

Download "Fire Protection Valves"

Transcription

1 4/4/EN/6 Fire Protection Valves Type FV-K90 FVZ-K30 with German Test Certificate (General Building Approval) Z Z TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/ Heinrich-Trox-Platz D Neukirchen-Vluyn

2 Contents Description Contents Description 2 Construction Standard Sizes 3 Applications Connection of Ventilation Ducts 4 Connection of Ventilation Ducts 5 Installation Details 6 Product Range 10 Technical Data 11 Order Details 12 FV-K90 FVZ-K30 Attention! The correct and safe operation of the fire protection valves must be checked at commissioning and by regular inspections. If after two inspections at six monthly intervals there are no functional problems then inspections can be extended to an annual basis. Maintenance work after commissioning is restricted to the removal of dirt which can impair operation of the equipment, e.g. in the thermal release mechanism. The maintenance intervals depend on the system engineering and operating conditions and must therefore be organised by the operator. Fire protection valves are licensed components. Therefore, the General and Special Provisions specified in the general building approvals and the instructions for installation, commissioning and maintenance which are enclosed with each delivery must be complied with when using the fire protection valves. Furthermore the general maintenance guidelines in accordance with DIN in connection with DIN EN must be complied with. Fire protection valves of the types FV-K90 and FVZ-K30 are designed for use in ventilation and air conditioning systems (HVAC) and in addition to fire protection, they also have a ventilation function. They can be used both in supply and extract air applications. The flow rate can be adjusted via the two position control unit. The valves are fixed into the wall with bayonet fixing and catch device to prevent accidental release. If the temperature of the air passing through the valve rises above 72 C, the fusible link parts and the valve centre disc springs to its closed position where it is mechanically locked. Material: Installation subframe, location spigot and valve disc are in sheet steel, installation subframe and location spigot stove-enamelled black, valve disc stove-enamelled white on visible surface (RAL 9010), valve cone of special asbestosfree insulation material, seal of polyurethane, attachments in galvanised steel. The General Building Approval Z and Z , the leaflet 4/4/EN/6 and the relevant assembly, commissioning and maintenance instructions MI-4/4/EN/6 can be found on the internet at The legal requirements for quality control are externally implemented by FMPA Baden-Württemberg. 2

3 Construction Standard Sizes Installation subframe: Masonry bolts and fixing elements for type FV-K90 supplied loose in a drawstring bag. Valve Insert: 2.1 Location spigot 2.2 Locking device 2.3 Fusible link 72 C 2.4 Closing spring 2.5 Sealing ring 2.6 Valve disc 2.7 Control device (position 1: large air volume, position 2: low air volume) 2.8 Bayonet fixing 2.9 Seal Trim ring Backing plate Fixing studs Type FV-K90 FVZ-K30 Z Z Application See table on page 4 Resistance class Depending on application Release temperature 72 C Standard Sizes NW, NW 125, NW 160, NW NW D D 1 D 2 D 3 D Type FV-K A 2.7 A D 72 C D 2 D Type FVZ-K30 D 2.7 B B C D D D 4 D 3 3

4 Applications Connection of Ventilation Ducts Application Construction/Material Minimum Fire resistance Fire resistance Installation details thickness class at class 1) See Page/Figure in mm minimum Z Z Wet Dry thickness FV-K90 FVZ-K30 Installation Installation 2) with/without with/without in solid walls Concrete Aerated concrete/lightweight concrete F90 K90/60 6/1.1 Masonry 115 in solid ceilings Concrete / Aerated concrete F90 K90/60 6/1.2 and 1.3 in wall boards Gypsum F180 K90/60 6/2.1 in lightweight Lightweight partition walls 75 F30 K30/30 7/3.1 7/3.2 partitions with gypsum plasterboard with metal supports cladding F90 K90/60 7/3.1 7/3.2 Fire rated partition walls with calcium silicate board 84 F90 K90/60 7/3.1 7/3.2 cladding Shaft walls / framework clad F30 K30/30 with non-combustible 90 or or 7/3.2 plasterboard F90 K90/60 Industrial partition walls F90 K90/60 7/3.1 7/3.2 in lightweight partitions without Fire rated partition walls metal supports made of calcium silicate 40 F90 K90/60 8/4.1 8/4.2 and walls with L90- boards ventilation ducts in fire-resistant Screwed / mortared 9/5.1 and 5.4 ceilings Lay in panels 9/5.2 and 5.4 (fire source from F30 K30U Metal panels above or below) 9/5.3 and 5.4 Fibre-free panels 1) with = in conjunction with a connected ventilation ducting made of non-combustible materials without = in conjunction with a combustible ventilation ducting 2) Optional dry installation type FV-K90 with fixing kit Connection of Ventilation Ducts According to the General Building Approval fire protection valves may only be connected to ventilation ducts that are unable to exert any significant force on the fire protection valve or wall or ceiling on account of duct work layout particularly when ducts heat up in the event of a fire. If this is not possible, flexible connectors must be located as shown in Ref. No. 3 or 6 for installation as shown in Fig. 1.1 to 2.1. For installation according to Figs. 3.1 to 4.2 ventilation ducts must only be used with flexible connectors as shown in Ref. No. 3 or 6. L1 Ventilation ducting made of non-combustible materials L2 Ventilation ducting made of combustible materials L3 Flexible, non-combustible ventilation ducting (ducts of steel or aluminium) S Flexible connector of B2 building materials according to DIN 4102 or flexible aluminium ducting acc. to DIN , flexible length mm when fitted Ö Opening, e.g. for a ventilation grille b > 1.5 ø D no protective screen necessary for opening b < 1.5 ø D Protective screen (mesh size max. 20 mm) made of non-combustible materials is necessary for opening * Fire resistance class K90 in walls or ceilings with a minimum fire resistance class of F90 4

5 Connection of Ventilation Ducts Ref. Application FV-K90 FVZ-K30 No. Fire Resistance Class* 1 Without ventilation ducting K60 Warning! For this application, the approval of the Building Authority is now required. 2 In shaft walls Shaft wall K90 3 Connection of a flexible, L3 K90 non-combustible ventilation ducting 4 Connection of a L1 Ö K90 non-combustible ventilation ducting b 5 Connection of a L2 L1 K90 combustible ventilation ducting min ,5 6 Connection of a flexible connector K90 L1 S and a non-combustible ventilation ducting 7 Connection of a flexible, K30-U non-combustible ventilation ducting min. L3 8 Connection of a flexible connector K30-U and a non-combustible ventilation ducting L1 min. S 5

6 Installation Details Installation in solid walls and ceilings Type FV-K90 Installation in concrete walls and ceilings with minimum thickness mm and masonry walls with minimum thickness 115 mm. Gap s to be filled with mortar from groups II or III, DIN 1053, or with concrete. The damper may also be fitted when the wall is built or during concreting. The peripheral gap s is not then required. Installation in gypsum wall boards Type FV-K90 Installation in gypsum wall boards according to DIN 18163, Part 1, gross density 0.6 kg/dm 3 with a minimum thickness of mm. The distance between the casing of two adjacent valves must not be less than 150 mm. The distance between the casing of two adjacent valves must not be less than 150 mm. Wall installation Ceiling installation Figure 1.1 Wall installation Figure 1.2 Vertical Installation in ceiling slab Figure 1.3 Suspended Installation in ceiling slab Figure 2.1 Installation in gypsum wall boards Figure 1.1 Figure 1.3 * Optional circular or square opening *D+approx. + ca D s Z04 *D+approx. + ca builders cleat L 300 Extension piece (V-part) Z04 for mounting in walls thicker than 115 mm (see page 10). Extension piece (V-part) Z04 for mounting in ceilings thicker than 115 mm (see page 10). * Optional circular or square opening Figure 1.2 Figure 2.1 bzw. or 120 *D+approx. + ca *D+approx. + ca plaster, mortar or plaster mortar builders cleat Extension piece (V-part) Z04 for mounting in ceilings thicker than 115 mm (see page 10). * Optional circular or square opening * Optional circular or square opening 6

7 Installation Details Partition wall (wall structure to manufacturers specifications) Reinforcing profile (corresponding to wall construction) Filler strip (material and material thickness corresponding to item ) Self tapping screw, steel (according to wall construction) * Installation frame, insulation material, 3 x 25 mm thick * Trim ring, steel, approx. 1 mm thick, circular or square Self tapping screw, steel (corresponding to wall structure) * Self tapping screw, steel, 4 x 35 Mortar group II or III, DIN 1053 or gypsum Figure 3.1 Figure 3.2 Size Hole Pitch Circle diameter Overall dimension circular diameter Overall dimension square Wall thickness W 75, wet installation Wall thickness W 75, dry installation with installation kit Installation in lightweight partition walls with metal supports Type FV-K90 Installation in lightweight partition walls, prefabricated walls, shaft walls and industrial partition walls with metal supports according to the test certificate, the Building Inspectorate Certificate or Approval. in at least 75 mm thick walls with plasterboard cladding in at least 84 mm thick fire rated partition walls made of calcium silicate boards in at least 90 mm thick shaft walls / facing formwork in at least mm thick industrial partition walls The distance between the casing of two adjacent valves must not be less than 150 mm. During the installation the fire protection valve must not be deformed, as this can result in impaired functionality. Ventilation duct connections are only permitted using flexible connectors or flexible ventilation ducts. Figure 3.1 Figure 3.2 builders cleat D+approx. D + ca D + 80 * optional * optional * * W W Extension piece (V-part) Z04 for mounting in walls thicker than 115 mm (see page 10). * Order item use code 11 or 12 (see page 10). Ventilation duct connections are only permitted using flexible connectors or flexible ventilation ducts (see page 4 and 5). Reinforcing profile layout see figure 3.1. * Order items, and use code 13 or 14 (see page 10). Ventilation duct connections are only permitted using flexible connectors or flexible ventilation ducts (see page 4 and 5). Reinforcing Profile Layout 7

8 Installation Details Installation in lightweight partition walls without metal supports and L90-walls Type FV-K90 Installation in at least 40 mm thick fire rated partition walls made of calcium silicate boards without metal supports and walls with L90-ventilation-ducts according to test certificate. The distance between the casing of two adjacent valves must not be less than 150 mm. During the installation the fire protection valve must not be deformed, as this can result in impaired functionality. Ventilation duct connections are only permitted using flexible connectors or flexible ventilation ducts. Partition wall (wall structure to the manufacturers specifications) Self tapping screw, steel (corresponding to wall structure) * Installation frame, insulation material, 3 x 25 mm thick * Trim ring, steel, approx. 1 mm thick, circular or square Size Hole Pitch Circle diameter Overall dimension circular diameter Overall dimension square Self tapping screw, steel (corresponding to wall structure) * Self tapping screw, steel, 4 x 35 Mortar group II or III, DIN 1053 or gypsum Figure 4.1 Figure 4.2 Wall thickness W 40 mm, Wet Installation Wall thickness W 40 mm, Dry Installation with kit Figure 4.1 Figure 4.2 builders cleat A D D+approx. + ca A D + 80 * optional * * optional * W W * Order item use code 11 or 12 (see page 10). Ventilation duct connections are only permitted using flexible connectors or flexible ventilation ducts (see page 4 and 5). * Order items, and use code 13 or 14 (see page 10). Ventilation duct connections are only permitted using flexible connectors or flexible ventilation ducts (see page 4 and 5). Size A Size A

9 Installation Details Ceiling type Make Construction Screwed / mortared all F30-A/AB Inlaid tiled ceiling all with fire source from above or below Metal panel ceiling Promatconstructions general appraisal according to the Lindnerconstructions certificate LMD Figure 5.1 Figure 5.2 Figure 5.3 Figure 5.4 Installation in screwed and mortared panelled ceiling Installation in lay in panelled ceiling Installation in metal panelled ceiling Detail of fixing Installation in fire resistant false ceilings F30 Type FVZ-K30 Suspended installation in fire resistant false ceilings, suitable for fire source from above or below, with resistance class F30. Scope of supply: items to Fire resistant ceiling F30 (supplied by others) Trim ring Countersunk self tapping screw 4 x 20 Back plate (Promatect-H) Self tapping screw 6 x 60 Threaded rod M4 x Nut M4 x diameter 16 x 3 Countersunk bolt M4 x 10 Hexagonal nut M4 Washer 4 DIN EN ISO 7093 Spacer M4 x SW9 x 14 Strip (Promatect-H) 20 x 40 (thickness depends on ceiling structure (supplied by others) Countersunk self tapping screw 4 x 40 (supplied by others) Figure 5.1 Figure 5.3 D D + 35 D D D + 35 D D + 76 D + 76 Figure 5.2 Figure 5.4 D D + 35 D Mortar group II or III, DIN 1053 or gypsum D

10 Product Range Product Range Accessories Electrical Limit Switch Installation Arrangement (Diagram shows Z01-Z03) Description Code FV-K90 FVZ-K30 With fusible link 72 C (standard construction) Z00 Protective cap D Limit switch indicates CLOSED Z01 Limit switch indicates OPEN Z Limit switch indicates CLOSED and OPEN Z03 Extension piece for wall or ceiling Z04 thickness 115 to 250 mm (riveted to the valve casing) Extension piece Z04 and Z05 limit switch indicates CLOSED L = 225 Extension piece Z04 and Z06 limit switch indicates OPEN Extension piece Z04 and Z07 limit switch indicates CLOSED and OPEN L = 300 (at Z04-Z07) Attachments Description Code FV-K90 FVZ-K30 Circular trim ring 11 Square trim ring 12 Installation kit for dry installation and 13 circular trim ring Installation kit for dry installation and 14 square trim ring Technical Data Function: Single pole change-over switch (shown with limit switch not activated) blue black brown I nom 5 A, 250 V; I therm 12 A Pure silver Switch rating: Contacts: Insulation: Group B (to DIN VDE 0110) Protection class: IP 66 Permitted ambient temperature: 5 C to + 70 C Connection cable: 3 x 0.75 mm 2, length approx. 2 m 10

11 Technical Data Nomenclature v L Example Data given: Supply air: Extract air: V = 40 l/s (144 m 3 /h) V = 40 l/s (144 m 3 /h) Size = 125 Size = 125 Position 1 Position 1 L L Required; V in l/s: Volume flow per fire protection valve V in m 3 /h: Volume flow per fire protection valve v L in m/s: Max. core velocity 0.25 m/s at distance L p t in Pa: Total pressure drop L WA in db(a): A-weighted sound power level L in m: Distance (throw) from centre of valve Pressure drop p t A-weighted sound power level L WA Distance L (for supply air) Result: Supply air: Extract air: p t = 85 Pa p t = 68 Pa L WA = 48 db(a) L WA = 47 db(a) L = 3.1 m Pressure drop p t in Pa Pressure Drop Sound Power Level Correction Values for Position 2 L WA in db(a) Supply air Supply air p t in Pa Extract air p t in Pa Supply air L WA in db(a) Extract air L WA in db(a) Size Value from graph x 2.1 x 2.2 x 2.4 x 2.4 x 3.7 x 3.7 x 3.9 x p t Position l/s m 3 /h Volume flow V Distance L (Throw) Pressure drop p t in Pa L WA in db(a) Extract air p t Position 1 Distance L in m Supply air Position 2 Position 1 v L = 0, m/s l/s m 3 /h Volume flow V l/s m 3 /h Volume flow V 11

12 Order Details Order Code No specification, if standard products FV - K90 / 160 / 11 / Z05 Type Designation FV -K90 FVZ-K Size Accessories Z01 to Z07 (see page 10) Z00 = Standard construction Attachments 11 to 14 (see page 10) 0 = without attachments Design changes reserved All rights reserved TROX GmbH (1/7) Specification Text Fire protection valve to seal fire compartments in an air conditioning system. With test certificate from the German Institute for Building Technology, Berlin. Suitable for use as supply or extract air disc valve with two position control unit for flow rate control. Easy maintenance, no tools required. Thermal release by fusible link at t > 72 C. Text for materials, application etc. can be taken from the leaflet. Make: TROX Type: FV-K90 FVZ-K30 Order Example Make: TROX Type: FV - K90 / 160 /11/ Z 05 No.: 4 12

Operating and Installation Manual Fire Damper Type FKA-EU

Operating and Installation Manual Fire Damper Type FKA-EU FKA-EU/DE/SCDE/ en Operating and Installation Manual Fire Damper Type FKA-EU according to Declaration of Performance DoP / FKA-EU / DE / 2013 / 001 3 Contents 1 PageHeaderToc 1 General information 3 Scope

More information

NEW. FR90 fire dampers. Maintenance-free

NEW. FR90 fire dampers. Maintenance-free NEW Maintenance-free FR90 fire dampers in short lengths for installation in rigid walls and ceilings and in metal stud walls Sizes: DN mm to DN 315 mm Fire classification: EI /60/90/120 (ve - ho, i o)

More information

Fire damper BSK-RB Contents Description...3 Models and dimensions...4 Installation...8 Technical data... 12

Fire damper BSK-RB Contents Description...3 Models and dimensions...4 Installation...8 Technical data... 12 Fire damper BSK-RB Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Phone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Quality assurance...

More information

Operating and Installation Manual Fire damper Type FKR-EU

Operating and Installation Manual Fire damper Type FKR-EU Operating and Installation Manual Fire damper Type FKR-EU tested to EN 1366-2 with EC Certificate of Conformity BC1-606 - 4645-15650.03-4651 Contents 1 General information 3 Other applicable documentation

More information

Declaration of performance

Declaration of performance Product Unique identification code of the product type FKRS-EU Intended use Fire damper Manufacturer TROX GmbH Phone +49 (0)2845 2020 Fax +49 (0)2845 202265 Heinrich-Trox-Platz E-mail trox@trox.de 47504

More information

Fire Prevention K90 and K30 dampers in accordance with DIN Part I 09/2006

Fire Prevention K90 and K30 dampers in accordance with DIN Part I 09/2006 Fire Prevention K90 and K30 dampers in accordance with DIN 4102-6 Part I 09/2006 40 30 20 50 L W db(a) 45 L W db(a) Total pressure loss pt [Pa] 10 6 4 35 L W db(a) 2 400 600 800 1000 1400 2000 2600. Volume

More information

Fire damper. Type FKS-EU. Installation and operating manual. GB/en. according to Declaration of Performance DoP / FKS-EU / DE / 003

Fire damper. Type FKS-EU. Installation and operating manual. GB/en. according to Declaration of Performance DoP / FKS-EU / DE / 003 and operating manual GB/en Fire damper Type FKS-EU according to Declaration of Performance DoP / FKS-EU / DE / 003 Read the instructions prior to performing any task! TROX GmbH Heinrich-Trox-Platz 47504

More information

Fire damper. Type FKRS-EU. Installation and operating manual. GB/en. according to Declaration of Performance DoP / FKRS-EU / DE / 003

Fire damper. Type FKRS-EU. Installation and operating manual. GB/en. according to Declaration of Performance DoP / FKRS-EU / DE / 003 and operating manual GB/en Fire damper Type FKRS-EU according to Declaration of Performance DoP / FKRS-EU / DE / 003 Read the instructions prior to performing any task! TROX GmbH Heinrich-Trox-Platz 47504

More information

Ordering example: BKI-K90/SFR1.90T/B=1000xH=1000xH=1000xL=250. Standard damper length; special dimensions are available on request

Ordering example: BKI-K90/SFR1.90T/B=1000xH=1000xH=1000xL=250. Standard damper length; special dimensions are available on request Ordering example: Damper BKI-K90/SFR1.90T/B=1000xH=1000xH=1000xL=250 Standard damper length; special dimensions are available on request Dimensions B x H (width x height) in mm, side H = operating side

More information

UL, KUL, WG-KUL, ARK, ARK-1

UL, KUL, WG-KUL, ARK, ARK-1 Installation manual GB/en Non-return dampers Types UL, KUL, WG-KUL, ARK, ARK-1 TROX GmbH Heinrich-Trox-Platz 47504 Neukirchen-Vluyn Germany Phone: +49 (0) 2845 2020 Fax: +49 (0) 2845 202265 E-mail: trox@trox.de

More information

Declaration of Performance

Declaration of Performance Product Unique identification code of the product type FK-EU Intended use Fire damper Manufacturer TROX GmbH Phone +49 (0)2845 2020 Fax +49 (0)2845 202265 Heinrich-Trox-Platz E-mail trox@trox.de 47504

More information

voestalpine Krems GmbH Wandanschlüsse an Betonwände bzw. Mauerwerk Wall connections to concrete walls/masonry Masonry, concrete or concrete blocks

voestalpine Krems GmbH Wandanschlüsse an Betonwände bzw. Mauerwerk Wall connections to concrete walls/masonry Masonry, concrete or concrete blocks Wandanschlüsse an Betonwände bzw. Mauerwerk Wall connections to concrete walls/masonry or concrete blocks or concrete blocks steel spacers steel spacers 100mm concrete masonry metal frame anchor ø10 e.g.

More information

Voie Romaine F Maizières-lès-Metz Tel.: +33 (0) Fax.: +33 (0) Operating vacuum pressure: - 500Pa

Voie Romaine F Maizières-lès-Metz Tel.: +33 (0) Fax.: +33 (0) Operating vacuum pressure: - 500Pa Voie Romaine F-57280 Maizières-lès-Metz Tel.: +33 (0)3 87 51 11 11 Fax.: +33 (0)3 87 51 10 58 CLASSIFICATION REPORT CLASSIFICATION REPORT no. 09 - A - 363 According to standards EN 15650: 2010 and EN 13501-3:

More information

EIV. Circular single deflection grille for walls. Quick facts. Quick guide EIV A I R F L O W - S O U N D L E V E L

EIV. Circular single deflection grille for walls. Quick facts. Quick guide EIV A I R F L O W - S O U N D L E V E L Circular single deflection grille for walls Quick facts Can be used with multi-function commissioning box Adjustable deflectors Simple installation Cleanable Available in alternative colours upon special

More information

BKP-EN Fire damper. Technical Documentation "Installation, Mounting and Operating Instructions" USABILITY CERTIFICATES PERFORMANCE DATA

BKP-EN Fire damper. Technical Documentation Installation, Mounting and Operating Instructions USABILITY CERTIFICATES PERFORMANCE DATA Technical Documentation "Installation, Mounting and Operating Instructions" Fig.: BKA-EN with B10 drive BKP-EN Fire damper USABILITY CERTIFICATES Performance Reliability Certificate according to EU-Bau

More information

0160 Series Curtain Fire Dampers

0160 Series Curtain Fire Dampers Burrell Way, General Description The 0160 series curtain fire dampers are designed to stop the spread of fire through ductwork, walls and floors in ventilation systems. When the fusible link reaches elevated

More information

Power IT Compact Secondary Substations, CSS. Technical catalogue for sheet steel substations

Power IT Compact Secondary Substations, CSS. Technical catalogue for sheet steel substations Power IT Compact Secondary Substations, CSS Technical catalogue for sheet steel substations The New Standard for Individual Solutions The new CSS substations represent a unique concept, which is introducing

More information

LVH-A Series Intumescent Fire Dampers Alternative Mounted Systems 1, 2 & 4 hour Fire Rating

LVH-A Series Intumescent Fire Dampers Alternative Mounted Systems 1, 2 & 4 hour Fire Rating LVH-A Series Intumescent Fire Dampers Alternative Mounted Systems 1, 2 & 4 hour Fire Rating For use in vertical and horizontal fire barriers COMPLETE DESIGN FREEDOM KEY FEATURES General Lorient LVH-A series

More information

Adjustable Suspension Hanger Technical Datasheet

Adjustable Suspension Hanger Technical Datasheet Adjustable Suspension Hanger sheet The Adjustable Suspension Hangers Clip are a component of the Keylock Ceiling System. The upper vertical side of the hanger allows the Suspension Rod that goes through

More information

2500 Series Fire Smoke Dampers

2500 Series Fire Smoke Dampers General Description The model 2550 is designed to prevent the spread of fire and smoke through ventilation ductwork in walls and floors. From receiving an alarm the power to the damper actuator is removed

More information

Internal Partitions - Timber Studs Internal Partitions - Steel Stud

Internal Partitions - Timber Studs Internal Partitions - Steel Stud Timber Studs PH Internal Partitions - Steel Stud / hour fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm PROMATECT -H

More information

FR90 fire dampers. Sizes 100 mm to 800 mm For universal use with a wide range of applications Fire classification: EI 30/60/90 (v e

FR90 fire dampers. Sizes 100 mm to 800 mm For universal use with a wide range of applications Fire classification: EI 30/60/90 (v e Maintenance-free FR90 fire dampers Sizes 100 mm to 800 mm For universal use with a wide range of applications Fire classification: EI /60/90 (v e - h o, i o) S C 10ooo Hygiene certificate Environmental

More information

FLAMRO FKS Ready Cable Duct System

FLAMRO FKS Ready Cable Duct System Mounting Instructions FLAMRO FKS Ready Cable Duct System These mounting instruction do not replace the test certificate of the fire protection cable ducts! They must be kept for the installation of fire

More information

1. Description Damper Design Dimensions, weights Placement and Assembly Statement of installations...

1. Description Damper Design Dimensions, weights Placement and Assembly Statement of installations... These technical specifications state a row of manufactured sizes and models of fire dampers (further only dampers) CFDM. It is valid for production, designing, ordering, delivery, assembly and operation.

More information

ALS 25 db(a) 30 db(a) 35 db(a) Size

ALS 25 db(a) 30 db(a) 35 db(a) Size Circular single deflection grille for walls QUICK FACTS Can be used with multi-function commissioning box Adjustable deflectors Simple installation Cleanable Standard colour White RAL 9003 -- 5 alternative

More information

EFECTIS France Voie Romaine F Maizières-lès-Metz Tel.: +33 (0) Fax.: +33 (0) A Revision 1

EFECTIS France Voie Romaine F Maizières-lès-Metz Tel.: +33 (0) Fax.: +33 (0) A Revision 1 EFECTIS France Voie Romaine F-57280 Maizières-lès-Metz Tel.: +33 (0)3 87 51 11 11 Fax.: +33 (0)3 87 51 10 58 CLASSIFICATION REPORT CLASSIFICATION REPORT no. 07 - A - 057 - Revision 3 According to standards

More information

DPG. Low velocity terminal for small airflows QUICK FACTS

DPG. Low velocity terminal for small airflows QUICK FACTS Low velocity terminal for small airflows QUICK FACTS Theatre diffuser for mounting in floor Fixed spread pattern Simple installation Requires no maintenance Cleanable Is available as special order in alternative

More information

1. Description Damper Design Dimensions, weights Placement and Assembly Statement of installations...

1. Description Damper Design Dimensions, weights Placement and Assembly Statement of installations... These technical specifications state a row of manufactured sizes and models of fire dampers (further only dampers) CFDM. It is valid for production, designing, ordering, delivery, assembly and operation.

More information

Assembly Instruction. FLAMRO Variant N II A / N II KS

Assembly Instruction. FLAMRO Variant N II A / N II KS Assembly Instruction / N II KS Please respect the permit specifications. All documents may be downloaded from www.flamro.com/services/downloads. It is assumed that - any damage to the seal will be repaired

More information

EI 30 barriere Self contained fire protection EI 30 from above and below smoke impervious EN

EI 30 barriere Self contained fire protection EI 30 from above and below smoke impervious EN O W A c e i l i n g i n f o r m a t i o n OWAcoustic EI 0 barriere Self contained fire protection EI 0 from above and below smoke impervious EN 4- Self contained fire protection EI 0 EI 0 barriere A Element

More information

1. Description Damper Design Dimensions, weights Placement and Assembly Statement of installations...

1. Description Damper Design Dimensions, weights Placement and Assembly Statement of installations... These technical specifications state a row of manufactured sizes and models of fire dampers (further only dampers) CFDM. It is valid for production, designing, ordering, delivery, assembly and operation.

More information

The Passive Fire Protection Handbook

The Passive Fire Protection Handbook The Passive Fire Protection Handbook The UK s comprehensive guide to passive ire protection Chapter Fire Rated Ductwork and Service Enclosures AUGUST 07 The Passive Fire Protection Handbook Contents Chapter

More information

CERTIFICATE OF APPROVAL No CF 5073 LEMINAR AIR CONDITIONING INDUSTRIES L.L.C.

CERTIFICATE OF APPROVAL No CF 5073 LEMINAR AIR CONDITIONING INDUSTRIES L.L.C. CERTIFICATE OF APPROVAL No CF 5073 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of PO Box 33539, Dubai,

More information

*1MUBWK25EN* *1MUBWK25EN-LIND* rev rev *1MUBWK25EN-LIND* WK25. RECTANGULAR SERIES WK Pa. Cert. N 1812-CPR-1045 EN 15650

*1MUBWK25EN* *1MUBWK25EN-LIND* rev rev *1MUBWK25EN-LIND* WK25. RECTANGULAR SERIES WK Pa. Cert. N 1812-CPR-1045 EN 15650 WK25 Installation booklet English RECTANGULAR SERIES WK25-500 Pa Cert. N 1812-CPR-1045 EN 15650 *1MUBWK25EN* *1MUBWK25EN-LIND* rev 17-04 rev 17-04 *1MUBWK25EN* *1MUBWK25EN-LIND* www.mp3-italia.it www.lindab.com

More information

mcr Silboard self-supporting ventilation and smoke extraction ducts

mcr Silboard self-supporting ventilation and smoke extraction ducts mcr Silboard self-supporting ventilation and smoke extraction ducts INTENDED USE mcr Silboard is a calcium-silicate fireproof board designed for the construction of e.g. self-supporting fireproof general

More information

3. Dimensions, weights Placement and Assembly Statement of installations Electrical Components, Connection Diagrams...

3. Dimensions, weights Placement and Assembly Statement of installations Electrical Components, Connection Diagrams... These technical specifications state a row of manufactured sizes and models of fire dampers (further only dampers) FDMC. It is valid for production, designing, ordering, delivery, assembly and operation.

More information

Date of update January 25, 2018 Valid until

Date of update January 25, 2018 Valid until CERTIFICATE PRODUCT APPLICATION VTT-C-4805-09 Date of update January 25, 2018 Valid until 12.10.2020 U Protect fire insulation solutions for ventilation ducts MANUFACTURER Saint-Gobain Finland Oy / ISOVER

More information

*1MUBWK45EN* *1MUBWK45EN-LIND* WK45. RECTANGULAR SERIES WK Pa / 300 Pa. Cert. N 1812-CPR-1006 EN Installation booklet English

*1MUBWK45EN* *1MUBWK45EN-LIND* WK45. RECTANGULAR SERIES WK Pa / 300 Pa. Cert. N 1812-CPR-1006 EN Installation booklet English WK45 Installation booklet English RECTANGULAR SERIES WK45-500 Pa / 300 Pa Cert. N 1812-CPR-1006 EN 15650 *1MUBWK45EN* *1MUBWK45EN-LIND* rev 17-04 rev 17-04 *1MUBWK45EN* *1MUBWK45EN-LIND* www.mp3-italia.it

More information

Sectional Overhead Doors SECTIONAL OVERHEAD DOORS

Sectional Overhead Doors SECTIONAL OVERHEAD DOORS Sectional Overhead Doors SECTIONAL Introduction WHY SPECIFY AND SELECT INSULATED SECTIONAL? This leaflet is offered by A& C M aintenance when presenting the arguments in favour of specification and selection

More information

Zinc-plated steel Stainless steel Hot-dip galvanised steel BUILDING MATERIALS

Zinc-plated steel Stainless steel Hot-dip galvanised steel BUILDING MATERIALS The all-round solution with short drill hole ADVANTAGES The special functioning allows for use in solid and hollow building materials with an anchorage of just 0 mm, ensuring an economical fixing. The

More information

Computer Room Floor Grille

Computer Room Floor Grille PI/9/1/B/2 Computer Room Floor Grille AFG TROX UK Ltd Telephone +44(0) 1842 754545 Caxton Way Telefax +44(0) 1842 763051 Thetford e-mail trox@troxuk.co.uk Norfolk IP24 3SQ www.trox.co.uk Contents Application

More information

All panels can be supplied in a range of styles, to suit the applications pictured below.

All panels can be supplied in a range of styles, to suit the applications pictured below. Evolution Radiant panel system LPHW up to 90 C Suspended ceiling grid or soffit mounting Vertical wall surface mounting Standard widths 150mm to 900mm 1 Description Introduction Evolution by Dunham-Bush

More information

Product Catalogue Telecommunication Hardware

Product Catalogue Telecommunication Hardware Product Catalogue Telecommunication Hardware Content Above-Surface Hardware Guy Clamp, Suspension Clamp and Suspension Pulley 4-5 Utility Pole Top Cover 6 Screw Anchor and Turnbuckle 7 Wall Hook, Guy Hook,

More information

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K T Premium Panel, protection category IP 69K IP 69 K.6 H H H Optionally with or without keyboard housing Resistant to high-pressure cleaning (protection category IP 69K). The seal lies between two surfaces

More information

Installation instruction

Installation instruction Installation instruction Ci51 www.contura.eu 114 CERTIFICATE Declaration of performance according to Regulation (EU) 305/2011 No. Ci51-CPR-150821-SE-2 PRODUCT Product type Type designation Manufacturing

More information

Universal frame fixing SXR-T

Universal frame fixing SXR-T The all-round solution with short drill hole depth. VERSIONS APPROVALS zinc-plated steel stainless steel BUILDING MATERIALS Approved for: Concrete C12/15 Vertically perforated brick Hollow blocks made

More information

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ductwork

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ductwork PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ductwork For Promat Asia Pacific Organisation February 0 Ductwork General Information i Steel duct claddings inside the Changi Water Reclamation

More information

*1MUBWKS25EN* *1MUBWKS25EN-LIND* rev rev *1MUBWKS25EN-LIND* WKS25. RECTANGULAR SERIES WKS Pa. Cert. N 1812-CPR-1046 EN 15650

*1MUBWKS25EN* *1MUBWKS25EN-LIND* rev rev *1MUBWKS25EN-LIND* WKS25. RECTANGULAR SERIES WKS Pa. Cert. N 1812-CPR-1046 EN 15650 WKS25 Installation booklet English RECTANGULAR SERIES WKS25-500 Pa Cert. N 1812-CPR-1046 EN 15650 *1MUBWKS25EN* *1MUBWKS25EN-LIND* rev 17-04 rev 17-04 *1MUBWKS25EN* *1MUBWKS25EN-LIND* www.mp3-italia.it

More information

Pipeline Accessories. PSI Wall Sleeves. General Information Selection Guide Technical Data Installation Instruction

Pipeline Accessories. PSI Wall Sleeves. General Information Selection Guide Technical Data Installation Instruction Pipeline Accessories PSI Wall Sleeves General Information Selection Guide Technical Data Installation Instruction 1 PSI Wall Sleeves made of steel General Information An economic method to seal hydrostatically

More information

Fire damper frequently asked questions for ASFP

Fire damper frequently asked questions for ASFP TG6 N42 Fire damper frequently asked questions for ASFP Fire Dampers to protect escape routes 1. Q. Can I use fire dampers where ductwork passes through an escape route such as a protected stairway or

More information

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling Application technology, 5th edition Volume III: Fonterra radiant heating and cooling Fonterra Active General Fonterra Active General Fonterra Active was developed specifically for thermal activation of

More information

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. SECTION 260529 - HANGERS AND SUPPORTS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. 1.2

More information

FD Damper Installation, Operating and Maintenance Instructions

FD Damper Installation, Operating and Maintenance Instructions FD Damper Installation, Operating and Maintenance Instructions 1 Health and Safety 1.1 Only competent personnel may carry out the work outlined within this document. 1.2 The wearing of appropriate Personal

More information

Standard program overview fire doors

Standard program overview fire doors Fire doors Standard program overview fire doors Fire-resistant and fire-proof steel doors Product Dimensions in mm width/height (clear opening) Tested as fire-resistant door in acc. with DIN 4102 / EN

More information

CGV/RGV. Sound attenuating transfer units

CGV/RGV. Sound attenuating transfer units Sound attenuating transfer units Quick facts For transfer air through walls Meets requirements for acoustic attenuation in normal constructions Flow range < 80 l/s Circular or rectangular hole in wall

More information

General Design Approval

General Design Approval General Design Approval Approval body for construction products and types of construction A public agency financed jointly by the Federal Government and the Länder Member of EOTA, UEAtc and WFTAO Date:

More information

SpotClip. Downlight covers for safe lighting installation in suspended ceilings

SpotClip. Downlight covers for safe lighting installation in suspended ceilings SpotClip Downlight covers for safe lighting installation in suspended ceilings SpotClip is a unique and innovative range products for the safe and easy installation Our inhouse team of developers at HellermannTyton

More information

PRODUCT CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE

PRODUCT CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE Certificate No C-11669-16 Issued June 14, 2016 Updated September 12, 2018 PRODUCT CERTIFICATE NAME OF PRODUCT Knauf Insulation Fire Insulation System for ventilation ducts MANUFACTURER Knauf Insulation

More information

Aluminium Single Deflection Grilles. Model Series 5100

Aluminium Single Deflection Grilles. Model Series 5100 Aluminium Single Deflection Grilles Model Series 5100 Aluminium Single Deflection Grilles Models 51SV and 51SH Single Deflection Supply Grilles are recommended for applications requiring pattern adjustment

More information

CDH/CLH. CleanZone Ceiling diffuser with micro-filter for supply air in clean rooms QUICK FACTS

CDH/CLH. CleanZone Ceiling diffuser with micro-filter for supply air in clean rooms QUICK FACTS CleanZone Ceiling diffuser with micro-filter for supply air in clean rooms QUICK FACTS Rectangular or circular duct connection Equipped with micro-filter H14 with gel or dry seal Painted interior Measurement

More information

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1 16 May 2014 Page 1 PART 1 GENERAL 1.1 DESCRIPTION This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories

More information

Befestigungssysteme - klimatechnisches Zubehör GmbH. Accessories for HVAC systems

Befestigungssysteme - klimatechnisches Zubehör GmbH. Accessories for HVAC systems Befestigungssysteme - klimatechnisches Zubehör GmbH Accessories for HVAC systems We offer self-manufactured components of the highest quality, as well as a well-rounded range of HVAC accessories. For more

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300

More information

Annex to the Accreditation Certificate D-ZE according to DIN EN ISO/IEC 17065:2013

Annex to the Accreditation Certificate D-ZE according to DIN EN ISO/IEC 17065:2013 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-ZE-11267-01-00 according to DIN EN ISO/IEC 17065:2013 Period of validity: 17.08.2018 to 01.10.2022 Holder of certificate: Materialprüfanstalt

More information

Architectural Shadowline Air Diffusion

Architectural Shadowline Air Diffusion Architectural Shadowline Air Diffusion PSD Series Perimeter Slot Diffuser In cooling mode, diffuser selection should be based on the ratio of the diffusers throw to the length of the zone/area being supplied,

More information

geba fire damper WFK according to EN 15650

geba fire damper WFK according to EN 15650 Installation- and operation instruction geba fire damper WFK according to EN 15650 with a free cross-section for the usage in ventilation systems in buildings Abbildung 1 DN 250 Tested according to EN

More information

Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19

Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19 Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19 Page 1 or 8 APPLICATION This fi re damper is intended to restrict the passage of fl ame. The standard installation requires that the

More information

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications:

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications: Query No.1 ; we need more specs. about fire resistant doors Answer to Query No. 1: The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general

More information

Volume flow rate measuring units

Volume flow rate measuring units X X testregistrierung Volume flow rate measuring units Type Statischer Differenzdrucktransmitter For the measurement of volume flow rates in ducts Rectangular volume flow rate measuring units for the recording

More information

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE Blast Resistant Enhanced Curtain Wall Blast Resistant Enhanced Curtain Wall Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION Grid based thermally insulated curtain wall system with

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # SECTION 26 0529 - HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

ThermaSheet. multi-purpose insulated tile backer panels

ThermaSheet. multi-purpose insulated tile backer panels ThermaSheet multi-purpose insulated tile backer panels A CODE PRODUCT DIMENSIONS RTTBB-06-1200 ThermaSheet Tile Backer Board 6mm 1200mm x 600mm RTTBB-10-1200 ThermaSheet Tile Backer Board 10mm 1200mm x

More information

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202-203 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300-301 QUANTITY FOR

More information

fischer fixing compass Cracked concrete.

fischer fixing compass Cracked concrete. fischer fixing compass Cracked concrete. Fixing solutions for a strong hold in cracked concrete. Highbond system FHB II Our strongest solution for cracked concrete. Relative tension load level: 100 % fischer

More information

SECTION OVERHEAD DOORS. Summary of Structural Steelwork Drawings SECT IONAL OVERH EAD D OORS

SECTION OVERHEAD DOORS. Summary of Structural Steelwork Drawings SECT IONAL OVERH EAD D OORS Summary of Structural Steelwork Drawings 550 min headroom 400 min headroom INSULATED GARAGE INSULATED REPAIR PANELS OSA Door Parts, Unit 4, Ashville Industrial Estate, Runcorn, Cheshire, WA7 3EZ. UK. HIGH

More information

Fibreglass poles: table of general features

Fibreglass poles: table of general features 432 Poles Poles 433 POLES 434 Fibreglass poles Fibreglass poles: table of general features h pole diam. Ø recommended recomended on base sinking h. mn Ø 60 acc. 50 1500 Ø 60 acc. 50 2000 Ø 60 acc. 50 250

More information

Duct Wrap Flexible Wraps

Duct Wrap Flexible Wraps Design No. 3MU/ 60-01 December 23, 2010 VENTILATION DUCT PROTECTION 3M Company 3M Fire Barrier Duct Wraps: 615 and 615+ 3M Fire Barrier Sealants: Water-Tight 1000-NS Silicone, Water-Tight 1003-SL Silicone

More information

SpotClip. Downlight covers for safe lighting installation in suspended ceilings

SpotClip. Downlight covers for safe lighting installation in suspended ceilings SpotClip Downlight covers for safe lighting installation in suspended ceilings SpotClip is a unique and innovative range products for the safe and easy installation Our in house team of developers at HellermannTyton

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING

More information

Air flue duct for use with ecotec boilers

Air flue duct for use with ecotec boilers For the installer Flue installation instructions Air flue duct for use with ecotec boilers Concentric System Ø 80/5 (Galvanized steel air duct/plastic flue duct) GB Contents Notes on the documentation

More information

FIRE damper type FDMD, is in all variants classified: as acc. EN and tested acc. EN and acc. EN

FIRE damper type FDMD, is in all variants classified: as acc. EN and tested acc. EN and acc. EN FIRE damper type FDMD, is in all variants classified: as acc. EN 13501 3 and tested acc. EN 1366 2 and acc. EN 15650. Installation in a solid wall construction 40 Solid wall construction Mortar or gypsum

More information

SECTION NON-STRUCTURAL METAL FRAMING

SECTION NON-STRUCTURAL METAL FRAMING SECTION 09 22 16 PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories

More information

ON-ROOF ATTACHMENT FLAT COLLECTOR HELIOSTAR

ON-ROOF ATTACHMENT FLAT COLLECTOR HELIOSTAR ON-ROOF ATTACHMENT FLAT COLLECTOR HELIOSTAR INSTALLATION INSTRUCTIONS ENERGY AND SANITARY SYSTEMS Installation requirements Generel requirements The on-roof attachment set is capable for installation of

More information

Conergy SolarFamulus II

Conergy SolarFamulus II Conergy SolarFamulus II Installation manual www.conergy.com Table of Contents Table of Contents SolarFamulus II for universal use on flat roofs 1 Introduction 1 1.1 Short description 1 1.2 Intended use

More information

RATING: Consult factory for availability Consult factory for availability

RATING: Consult factory for availability Consult factory for availability DYNAMIC FIRE DAMPER MODELS: 75A-DY (1-1/2 HR rating) APPLICATION The model 75A-DY is constructed with standard constructiongalvanized steel. 75A-DY is 1-1/2 hour UL rated dynamic damper for use in HVAC

More information

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES 04 05 PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Over floor trunking 0 300 9 0 300 93 0 38 00 Conform to standard EN 50085-- For creating a link between trunking, column,

More information

SORDO. General. Sound attenuator for circular ducts

SORDO. General. Sound attenuator for circular ducts Sound attenuator for circular ducts General A circular sound attenuator with circular connection spigots. Unique properties regarding fire-resistance class, fibre-migration proof design and sound attenuation.

More information

installation instructions Combination Fire & Smoke Damper

installation instructions Combination Fire & Smoke Damper Combination Fire & Smoke Damper Sleeve Fire Rated Partition Retaining Angle Combination Fire & Smoke Damper Actuator General Notes: Combination Fire & Smoke Dampers are approved for use in static or dynamic

More information

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION SECTION 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 - GENERAL 1.1 SUMMARY A. This section supplements all sections in this division, including pipe, fittings, valves, and connections for sprinkler

More information

56-SDMS-01 REV. 01 SPECIFICATIONS FOR

56-SDMS-01 REV. 01 SPECIFICATIONS FOR 56-SDMS-01 REV. 01 SPECIFICATIONS FOR 13.8KV UNIT SUBSTATIONS This specification is property of SEC and subject to change or modification without any notice CONTENTS PAGE No. 1.0 SCOPE 3 2.0 CROSS REFERENCES

More information

European Technical ETA-04/0023 Assessment of 17 October 2017 General Part

European Technical ETA-04/0023 Assessment of 17 October 2017 General Part European Technical Assessment ETA-04/0023 of 17 October 2017 - Original version in German language General Part Technical Assessment Body issuing the European Technical Assessment: Trade name of the construction

More information

Smoke Control Damper ESAM Instructions for installation, operation and maintenance 10/2014

Smoke Control Damper ESAM Instructions for installation, operation and maintenance 10/2014 Instructions for installation, operation and maintenance 0/204 General The rectangular smoke control damper ESAM is specially designed for use in multi fire-compartment applications as a closing or opening

More information

CERTIFICATE OF APPROVAL No CF 429 PROMAT UK LTD

CERTIFICATE OF APPROVAL No CF 429 PROMAT UK LTD CERTIFICATE OF APPROVAL No CF 429 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of The Sterling Centre,

More information

SDW. Supply air diffuser for wall mounting in small premises QUICK FACTS

SDW. Supply air diffuser for wall mounting in small premises QUICK FACTS Supply air diffuser for wall mounting in small premises QUICK FACTS Supply air diffuser designed for small premises, for example, homes and offices Mounted on a wall close to the ceiling emovable front

More information

LLOYD INDUSTRIES INC. DAMPER INSTALLATION INSTRUCTIONS

LLOYD INDUSTRIES INC.   DAMPER INSTALLATION INSTRUCTIONS Installation and Maintenance Instructions 1-1/2 Hour Rated, UL Classified model 75 fire dampers For use in fire barriers with ratings of less than 3 hours INSPECTION 1. Inspect for shipping damage. 2.

More information

SORDO. Sound attenuator for circular ducts QUICK FACTS

SORDO. Sound attenuator for circular ducts QUICK FACTS Sound attenuator for circular ducts QUICK FACTS Mineral wool covered with special polyester woven fabric. 100 mm shorter Tightness Class D Excellent sound attenuation Type-approved to Fire-resistance Classes

More information

Installation instructions

Installation instructions Installation instructions Holetherm Double-walled flue gas discharge system (DW) 2016 All information in this release is subject to misprints. No liability is accepted for the consequences of misprints.

More information

Thermocouples Straight Design Model TC501, for Flue Gas Measurement

Thermocouples Straight Design Model TC501, for Flue Gas Measurement Electrical Temperature Measurement Thermocouples Straight Design Model TC501, for Flue Gas Measurement WIKA Data Sheet TE 65.30 Applications T Blast furnaces, air heaters T Red-heat and heat treatment

More information

Luna - design arch. Valenti

Luna - design arch. Valenti 422 Luna - design arch. Valenti ø 89/152, silver colour steel pole. Complete with inspection window with removable terminal strip. For the version with base, 4 log bolts to be sunk into the ground, bolts

More information