1 CABLEMASTER COAXIAL, DATA, TELEPHONE & SPECIAL CABLES CABLE GUIDE REFERENCES: FOXTEL F10231, F30128 OPTUS SAP17874, SAP4868 AS/ACIF S008:2001 N2020 Skandia Pty Ltd Issue: 2.0 Revision: 1 Date of issue: 1 September 2009 Commercial in Confidence 1 of 22
2 TABLE OF CONTENTS RG 59 SPECIFICATIONS... 3 RG59 TRIO SPECIFICATIONS... 4 RG6 DUAL SPECIFICATIONS... 5 RG6 QUAD SPECIFICATIONS... 6 RG6 QUAD SIAMESE SPECIFICATIONS (2 x RG6 QUAD)... 7 RG6 QUAD MICKEY MOUSE SPECIFICATIONS... 8 RG59 SMART CABLE (RG59 & CAT5E & 2 CORES)... 9 RG6 SMART CABLE (2 x RG6 QUAD & 2 X CAT5E) TEL1Q/0.4 LEAD IN CABLE CORE SECURITY 7/ CORE SECURITY 14/ CORE SECURITY 14/ CAT 5E CABLE SPECIFICATIONS UTP CAT 5E PVC SHOTGUN (2 x CAT5E) UTP CAT6 CABLE SPECIFICATIONS FIGURE 8 POWER CABLE 24/ SWTP-1.5 SPEAKER CABLE SPECIFICATIONS SWBT-1.0 SPEAKER CABLE SPECIFICATIONS mm 2 SOLAR DC TWIN CABLE mm 2 SOLAR DC TWIN CABLE Commercial in Confidence 2 of 22
3 RG 59 SPECIFICATIONS ORDERING CODE: RG59 INNER BOX: 4 ROLLS Version: A 0 PACKAGING: 100 METRE ROLLS PALLET: 160 ROLLS Page: 1 / 1 PRODUCT NAME: RG59 COAXIAL CABLE 1.CONSTRUCTION Shield 2.DESIGN NO./mm CCS 0.643CCS ( +/ ) Copper Clad Steel NO./mm FPE (+/-0.18) Foam PE NO./mm 32 (+/-2) AL/PET foil shield 32 / T0.12 T0.12 ( +/ ) Tinned copper braid shield NO./mm PVC (+/-0.25) Black PVC jacket Foil shield & Braid shield PVC jacket Foam PE insulation Item Description Standards 1. Resistance 20 C conductor DC Resistance < 19.0 Ω / 100 m 2. Resistance 20 C, Resistance > 500 MΩ 3. Capacitance 50 ±8 pf / m 4. Velocity ratio C 50 MHz 9.25 db 5. Attenuation db / 100 m 100 MHz db (+/-10%) 450 MHz db 1000 MHz db Commercial in Confidence 3 of 22
4 RG59 TRIO SPECIFICATIONS Version: ORDERING CODE: RG59 TRIO INNER BOX: 2 ROLLS A0 PACKAGING: 100 METRE ROLLS PALLET: 60 ROLLS Page: 1 / 1 PRODUCT NAME: RG59 TRIO CABLE 1.CONSTRUCTION Shield 2.DESIGN NO./mm / T0.80 (+/-0.02) Solid Tinned Copper NO./mm 3.70 Red, Green, Blue 3 / 3.70 FPE ( +/-0.18 ) Foamed PE insulation Al foil Al foil shield 3 / T ( +/-2 ), 0.12 ( +/ ) Tinned copper braid shield NO./mm 6.00 (+/-0.20) PVC 18.0 ( +/-0.60 ) Black PVC jacket RED GREEN BLUE Actual cables are round. Suitable for termination in round barrel type of connectors. Color of insulation: Red, Green, Blue Color of outer jacket: Black Item Description Standards C, DC Resistance < 3.99 Ω / 100 m 2. Braid overlap 30 ±3 % 3. Capacitance 53.2 ±3 pf / m 4. Velocity ratio 83.0 ±3 % 5. Characteristic 20 C, 200MHz 75.0 ±3 Ω 55 MHz C 211 MHz db 6. Attenuation db / 100 m 450 MHz db (+/-10%) 750 MHz db 1,000 MHz db Commercial in Confidence 4 of 22
5 RG6 DUAL SPECIFICATIONS RG6 DUAL/100M ORDERING CODE: RG6DUAL/RB RG6DUAL/REEL PACKAGING: 100 METRE REEL & 305 METRE QUICK PULL BOX & 305 METRE REEL PRODUCT NAME: RG6 COAXIAL CABLE (DUAL) 100M REEL: 4 ROLLS PER INNER BOX, PALLET: 160 ROLLS 305M QUICK PULL BOX OR REEL: 45 PER PALLET 1.CONSTRUCTION Version: A0 Page: 1 / 1 Shield 2.DESIGN NO./mm mm CCS (+/-0.020) Copper Clad Steel NO./mm FPE ( +/-0.20 ) Foamed PE insulation B-AL/PET Bonded AL/PET 64 / AL0.16mm 0.16 ( +/ ) Aluminum wire braid shield NO./mm PVC ( +/-0.30 ) Black PVC jacket Aluminum / mylor PVC Braid shield Foam PE insulation Item Description Standards 1. Resistance 20 C, DC Resistance < 100 Ω / km 2. Braid overlap > 60 % 3. Capacitance 53.2 ±3 pf / m 4. Velocity ratio 83.0 ±3 % 5. Characteristic Impedance 20 C, 200MHz 75.0 ±3 Ω 55 MHz C 211 MHz 9.43 db 6. Attenuation db / 100 m 450 MHz db (+/-10%) 750 MHz db 1000 MHz db Commercial in Confidence 5 of 22
6 RG6 QUAD SPECIFICATIONS RG6 QUAD/100M ORDERING CODE: RG6 QUAD RG6QUAD/RB RG6QUAD/REEL PACKAGING : 305 METRE QUICK PULL BOX OR REEL & 100 METRE REEL PRODUCT NAME : RG6U (QUAD) COAXIAL CABLE 100M REEL, 4 ROLLS PER INNER BOX, PALLET: 160 ROLLS 305M QUICK PULL BOX OR REEL: 45 PER PALLET 1.CONSTRUCTION Shield 2.DESIGN Version: A0 Page: 1 / 1 NO./mm CCS (+/-0.020) Copper Clad Steel NO./mm (+/-0.20 ) Foamed PE insulation B-AL/PET breadth 18(+/-0.5)mm Bonded AL/PET foil 64 / 0.16(AL) 64 (+/-2) ; 0.16 (+/-0.01) Aluminum wire braid shield AL/Pes/AL breadth 20(+/-0.5)mm AL/PET/AL foil shield 48 / 0.16(AL) 48 (+/-2) ; 0.16 (+/-0.01) Aluminum wire braid shield NO./mm PVC ( +/-0.30 ) Black PVC jacket Inner shield Item Description Standards 1. Resistance 20 C, DC Resistance < 10.0 Ω / 100 m 2. Capacitance 53.5 ±5 pf / m 3. Velocity ratio 83 ±3 % 4. Characteristic 200 MHz 75 ±3 Ω 5. Attenuation PVC jacket Outer shield 50 MHz 4.90 db 100 MHz 6.90 db 450 MHz C 860 MHz db db / 100 m 1000 MHz db (+/-10%) 1750 MHz db 2150 MHz db 2450 MHz db 3000 MHz db Commercial in Confidence 6 of 22
7 RG6 QUAD SIAMESE SPECIFICATIONS (2 x RG6 QUAD) ORDERING CODE: RG6 QUAD SIAMESE Version: A0 PACKAGING: 150 METRE REEL REEL: 45 PER PALLET Page: 1 / 1 PRODUCT NAME: RG6 QUAD SIAMESE COAX CABLE 1.CONSTRUCTION Shield 2.DESIGN NO./mm / 1.02 CCS (+/-0.020) Copper Clad Steel NO./mm / 4.60 FPE (+/-0.20 ) Foamed PE insulation NO./mm 2 / B-AP Bonded AL foil shield 2 / 0.16(AL) (+/-2) ; 0.16 (+/-0.01) Aluminum wire braid shield 2 / APA Double AL foil shield 2 / 0.16(AL) (+/-2) ; 0.16 (+/-0.01) Aluminum wire braid shield NO./mm 7.40 ( +/-0.30 ) ( +/-0.50 ) Black PVC jacket (Figures are not to scale) Inner shield Figure 1 Figure 2 Front view of Siamese pair Side view of one of the Siamese pairs Item Description Standards C, DC Resistance < 10.0 Ω / 100m 2. Capacitance 53.5±5 pf / m 3. Velocity Ratio 83.2±3 % 4. Characteristic 20 C, 200MHz PVC jacket Outer shield 75±3 Ω 55 MHz 4.94 db 100 MHz C 211 MHz 9.43 db 5. Attenuation db / 100 m 400 MHz db (+/-10%) 870 MHz db 1000 MHz db 2150 MHz db 2450 MHz db 3000 MHz db Commercial in Confidence 7 of 22
8 RG6 QUAD MICKEY MOUSE SPECIFICATIONS (RG6QUAD & 1PAIR TELEPHONE & MESSENGER) Product Code: RG6QUAD MM Multi-construction (A) Coaxial + (B) 1Pair + (C) Messenger Cable Construction (A) Coaxial (B) 1Pair (C) Messenger (A) Electrical Characteristics Maximum DC Resistance at 20 C (Ω/km) <103.6 Minimum DC Resistance at 20 C (MΩ/km) >500 Rated Temperature ( C) 80 Rated Voltage (V) 30 CCS Bare Copper GSW Capacitance (pf/m) <54 Conductivity 22% Velocity ratio (%) Construction Impedance (Ω) 75+/-3 Standard Dia.(mm) Attenuation at 20 C (db/100m) (+/-10%) Gas Injected 100 MHz PE PE MHz Thickness MHz MHz MHz MHz Dia.(±0.08mm) Color Nature Orange & White/Orange Bonded Al-Foil Shield Al/Pet/Adhibit Return Loss ( -db ) MHz MHz MHz Construction (μ) 50μ MHz--30 MHz >26 Coverage 125% MHz MHz >26 Aluminum Braiding wire (B) Electrical Characteristics Construction 0.16Al Maximum DC Resistance at 20 C (Ω/km) <56.1 Braiding coverage >61% Rated Temperature ( C) 80 Al-Foil-Al Shield Al/Pet/Al Rated Voltage (V) 300 Minimum DC Resistance at 20 C Construction (μ) 9/23/ (MΩ/Km) 200 Coverage 125% Aluminum Braiding wire Marking (White Ink) (High: 2.5mm) Construction 0.16Al RG6 QUAD SHIELD SIAMESE MESSENGER Braiding coverage >46% OHMS +001M +305M A Rip Cord D PVC UV-resistant Packaging Thickness(mm) m reel Dia.(+/-0.2mm) Approximately reels per pallet Color Design Black MICKEY MOUSE CABLE 40 m m 310 Commercial in Confidence 8 of mm
9 RG59 SMART CABLE (RG59 & CAT5E & 2 CORES) Product Description: RG59 SMART CABLE (A) Electrical Characteristics Application: LAN and backbone Max. DC Resistance at 20 C Ω/km <235 Reference Standards: EIA/TIA 568A ISO/IEC Min. DC Resistance at 20 C MΩ/km >1000 Multi-construction RG59 UTP CAT5E 2x0.75 Rated Temperature ( C) 80 Cable Construction (A) (B) (C) Rated Voltage (V) 30 (RG59 ) (UTP CAT5) (2Cores) Capacitance (pf/m) <70 Copper Bare Bare copper Clad Steel copper Velocity ratio (%) 66.7 Conductivity 30% Impedance(Ω) 75+/-3 Construction Attenuation at 20 C (db/100m) (db) Stranded Dia. (mm) MHz 8.50 Layer Solid PE HDPE PVC 100MHz Min. Thickness(mm) MHz D (±0.08mm) MHz color Natural Red 800MHz Black 860MHz Braiding(mm) Bare Copper MHz Construction 0.11x16x Braid Coverage (%) >80% (B) Electrical Characteristics A Rip Cord D Performance Inner PVC PVC Frequency (MHz) RL (db) Attenuation NEXT ACR min (db/100m) (db) (db) Min. Thickness(mm) Dia.(±0.15mm) color Black Blue Total mylar spiral >115% A rip cord 1000D Common Outer PVC Min. Thickness(mm) Diameter (±0.20mm) color Transparent (B) color Blue, ELFEXT PSELFEXT Impedance Frequency (MHz) White/Blue (MHz) (db) (Ohm) Orange, White/Orange Green, White/Green Brown, White/Brown (C) Electrical Characteristics Max. DC R at 20 C Ω/km < Rated Temperature ( C) Rated Voltage (V) Resistance (MΩ/km) >200 ( Characteristics + Max. DC R at 20 C (Ω/km) <94.8 PACKAGING / Rated Temperature ( C) m reel (wooden) - Velocity ratio 65% Approximately reels / pallet DESIGN % ) B 200 C A 100 +/-15 Commercial in Confidence 9 of 22
10 RG6 SMART CABLE (2 x RG6 QUAD & 2 X CAT5E) Product Description: RG6QUAD SMART CABLE (A) Electrical Characteristics APPLICATION: LAN, WAN, backbone Max. DC Resistance at 20 C, Ω/km <22.8 REFERENCE STANDARD: EIA/TIA 568A ISO/IEC Min. DC Resistance at 20 C, MΩ/Km >500 Construction 2 x RG6 QUAD 2 x UTP CAT 5E Rated Temperature ( C) 80 Cable (A) Coaxial (B) UTP Cat 5E Rated Voltage (V) 30 Copper C d Steel Bare Copper Capacitance (pf/m) <60 Conductivity 22% Velocity ratio 82.50% Construction Impedance(Ω) 75+/-3 Standard mm Attenuation at 20 C (-db/100m) (+/-10%) Gas Injected PE PE 100 MHz MHz Thickness MHz MHz mm MHz MHz Color Neutral Various Return Loss ( -db ) Bonded Al Shield Al/Pet/Adhibit MHz--30 MHz >26 Construction (μ) 50μ MHz MHz >26 Coverage 125% (B) Electrical Characteristics Braiding Aluminum wire Frequency (MHz) RL (db) Attenuation NEXT (db) ACR (db) Construction 0.16Al db 1.82 db/100m db db Braiding coverage >61% Al-Foil-Al Shield Al/Pet/Al Construction (μ) 9/23/ Coverage >115% Braiding Aluminum wire Construction 0.16Al Braiding coverage >46% A Rip Cord D Inner PVC PVC Thickness(mm) 0.86 >= (+/-0.2mm) Frequency (MHz) ELFEXT (db) PSELFEXT Impedance (Ω) Inner Color See the design db db Total Mylar Spiral >=115% Rip Cord 1000D Outer PVC Thickness (mm) >= (+/-0.15mm) ±15 Common Outer Transparent Marking CABLEEMASTER RG6 SMART (B( Color PACKAGING Blue, White/Blue Max. DC Resistance at 20 C Ω/Km <94.8 Orange, White/Orange Rated Temperature ( C) 80 Green, White/Green Velocity ratio 65% Brown, White/Brown DESIGN m reel, wooden Approximately reels per pallet Black Grey Blue White Commercial in Confidence 10 of 22
11 TEL1Q/0.4 LEAD IN CABLE PRODUCT DESCRIPTION: Two pair (One quad) 0.40 mm Lead In Cable with Plain Copper, insulated with solid Polymeric material, Unfilled Core and PE Sheet APPLICATION: ORDERING: PACKAGING: Connection of voice and data services to customer premises, suitable for outdoor use in lieu of gel filled cable TEL1Q/0.4 Twin Boxes (2 x 500 m Quick Pull Boxes per Twin Box) Approximately 40 x Twin Boxes per pallet DIMENSIONS & COLORS ELECTRICAL SPECIFICATIONS Bare Diameter: Insulated Diameter: Thickness Nominal: Thickness Minimum: Cable Diameter Nominal / Tolerance: Sheet Wall Thickness Nominal / Minimum: Outer Color: : / mm 0.85mm Nominal 0.22mm 0.13mm 3.50mm +/- 0.5mm 0.70mm / 0.60mm Black White / Blue / Red / Black Loop Resistance: Mutual Capacitance: Pair to Pair Capacitance Unbalance: Dielectric Breakdown Test: Resistance ohms/km: Loop Resistance ohms/km: Mutual Capacitance 1kHz Capacitance Unbalance pf/km to Ground: ohms/km nf/km for each pair Mean value nf/km 1,200 nf/km 2.5 kv DC DRAWING: The drawing below is for illustration purpose only. It is not to scale. insulation: MARKING White Blue Red Black Outer insulation insulation (4 off) Copper (4 off) Commercial in Confidence 11 of 22
12 4 CORE SECURITY 7/020 ORDERING CODE: SC47020 INNER BOX :4 Reels Version: A0 PACKAGING: 100mtr & 300mtr PALLET: 60 Reels PRODUCT NAME : Security cable 4 Core 1.CONSTRUCTION Page: 1 / 1 Shield NO./mm BC / BC 0.20*7 ( / ) Stranded Bare copper NO./mm 1.10 red,blue,yellow,black 4 / 1.10 (+/-0.13 ) PVC insulation NO./mm 2.DESIGN NO./mm 3.60 Rip-cord 3.60 (+/-0.18 ) Grey PVC Item Description Cond. Res. 20, DC Resistance < 9.41Ω/100M Insu. Res. 20, DC Resistance > 200 MΩ.M Rated Tem Rated Voltage V *Remark: Please contact us if you have more requirements or specifications subject to change,or else in accordance with the standards.* Commercial in Confidence 12 of 22
13 4 CORE SECURITY 14/020 ORDERING CODE: SC INNER BOX :4 Reels Version: A0 PACKAGING: 100mtr & 300mtr PALLET: 60 Reels PRODUCT NAME : Security cable 4 Core 1.CONSTRUCTION Page: 1 / 1 Shield NO./mm BC / BC 0.20*14 ( / ) Stranded Bare copper NO./mm 1.50 red,blue,yellow,black 4 / 1.50 (+/-0.13 ) PVC insulation NO./mm 2.DESIGN NO./mm 4.70 Rip-cord 4.70 (+/-0.20 ) Grey PVC Item Description Cond. Res. 20, DC Resistance < 4.71 Ω/100M Insu. Res. 20, DC Resistance > 200 MΩ.M Rated Tem Rated Voltage V *Remark: Please contact us if you have more requirements or specifications subject to change,or else in accordance with the standards.* Commercial in Confidence 13 of 22
14 6 CORE SECURITY 14/020 ORDERING CODE: SC INNER BOX :4 Reels Version: A0 PACKAGING: 100mtr & 300mtr PALLET: 60 Reels PRODUCT NAME : 6 Core Security cable 1.CONSTRUCTION Page: 1 / 1 Filler 2.DESIGN NO./mm BC / BC 0.20*14 ( / ) Stranded Bare copper NO./mm 1.50 green,white,red,blue,yellow,black 6 / 1.50 (+/-0.13 ) PVC insulation NO./mm 1.50 black 1.50 (+/-0.13 ) PVC Filler NO./mm 6.10 Rip-cord 6.10 (+/-0.25 ) Grey PVC Item Description Cond. Res. 20, DC Resistance < 4.71 Ω/100M Insu. Res. 20, DC Resistance > 200 MΩ.M Rated Tem Rated Voltage V *Remark: Please contact us if you have more requirements or specifications subject to change,or else in accordance with the standards.* Commercial in Confidence 14 of 22
15 CAT 5E CABLE SPECIFICATIONS ORDERING CODE : CAT5E Version: A0 PACKAGING : 305 METRE BOX PALLET: 45 ROLLS Page: 1 / 1 PRODUCT NAME: UTP CAT.5E CABLE (SOLID) 1.DESIGN 2.CONSTRUCTION NO./mm / 0.51mm ( +/-0.01 ) Solid bare copper wire NO./mm Pairs 8 / 0.91mm (+/-0.05 ) Solid HD-PE insulation 24 AWG Frequency (MHz) Attenuation (db) Color code Pair 1 Pair 2 Pair 3 Pair 4 White-Blue Blue White-Orange Orange White-Green Green White-Brown Brown NO./mm 5.20 Rip-cord Individual conductors are twisted into pairs to minimize crosstalk. Color combinations are used to provide pair identification PVC ( +/-0.50 ) Flame retardant PVC jacket RL (db) Next Worst Pair (db) Next Power Sum (db) ELFEXT Worst Pair (db) ELFEXT Power Sum (db) Impedance (Ohm) 100±15 Commercial in Confidence 15 of 22
16 Product Description: CAT 5E SHOOTGUN UTP CAT 5E PVC SHOTGUN (2 x CAT5E) Application: Performance 100 Base-T4 Frequency RL Attenuation NEXT ACR 100 Base-TX (MHz) (db) (db/100m) 100VG - LAN min. max (db) (db) 1000 Base-T (Gigabit Ethernet) Mbps ATM Mbps AT LAN Wiring Reference Standard EIA/TIA 568A & ISO/IEC Multi-construction Pair Cable Construction Solid Bare Copper AWG Diameter 0.50 Frequency ELFEXT PSELFEXT Impedance(Ω) HDPE (MHz) (db) (db) Average Thickness Diameter (mm) Rip cord 150D PVC Thickness (mm) >= Diameter (mm) ±15 Color Blue / Grey Color colors: Blue, White/Blue Orange, White/Orange Green, White/Green Characteristics Brown, White/Brown Maximum DC Resistance at 20 C Ω/Km <94.80 Rated Temperature ( C) 80 Velocity ratio 65% color Text Marking (on jacket) ORDERING CODE BLUE / GREY CABLEMASTER UTP CAT5E SHOOTGUN CAT5E SHOOTGUN PACKAGING 150 meters Quick Pull Box DESIGN Color of jacket is not shown on the drawing below Webbing between cables is BLUE GREY not to scale Box size: mm Commercial in Confidence 16 of 22
17 UTP CAT 5E PVC (COLORED) Product Description: CAT 5E Application: Performance 100 Base-T4 Frequency RL Attenuation NEXT ACR 100 Base-TX (MHz) (db) (db/100m) 100VG - LAN min. max (db) (db) 1000 Base-T (Gigabit Ethernet) Mbps ATM Mbps AT LAN Wiring Reference Standard EIA/TIA 568A & ISO/IEC Multi-construction Pair Cable Construction Solid Bare Copper AWG Diameter 0.50 Frequency ELFEXT PSELFEXT Impedance(Ω) HDPE (MHz) (db) (db) Average Thickness Diameter (mm) Rip cord 150D PVC Thickness (mm) >= Diameter (mm) ±15 Color Red/Green/Grey/Blue/Yellow Color colors: Blue, White/Blue Orange, White/Orange Green, White/Green Characteristics Brown, White/Brown Maximum DC Resistance at 20 C Ω/Km <94.80 Rated Temperature ( C) 80 Velocity ratio 65% color Text Marking (on jacket) ORDERING CODE RED CABLEMASTER UTP CAT5E R CAT5E RED GREEN CABLEMASTER UTP CAT5E GR CAT 5E GREEN GREY CABLEMASTER UTP CAT5E GY CAT5E GREY BLUE CABLEMASTER UTP CAT5E UG CAT5E BLUE YELLOW CABLEMASTER UTP CAT5E Y CAT5E YELLOW PACKAGING DESIGN Color of jacket is not shown on the drawing below 100 meters Quick Pull Box Box size: mm JACKET: RED GREEN GREY BLUE YELLOW Commercial in Confidence 17 of 22
18 UTP CAT6 CABLE SPECIFICATIONS ORDERING CODE : CAT6 Version: A0 PACKAGING : 305 METRE BOX PALLET: 45 ROLLS Page: 1 / 1 PRODUCT NAME: UTP CAT6 CABLE (SOLID) 1.DESIGN 2.CONSTRUCTION NO./mm / 0.574mm ( +/-0.01 ) Solid bare copper NO./mm Pairs 8 / 1.04 mm (+/-0.05 ) Solid HD-PE insulation 23 AWG Frequency (MHz) Attenuatio n (db) Color code Pair 1 Pair 2 Pair 3 Pair 4 White-Blue Blue White-Orange Orange White-Green Green White-Brown Brown NO./mm 6.30 Rip-cord Individual conductors twisted into pairs to minimize crosstalk. Color combinations are used to provide pair identification. Patented Design with Isolator-TM separator 6.30 PVC ( +/-0.5 ) Flame retardant PVC jacket RL (db) Next Worst Pair (db) Next Power Sum (db) ELFEXT Worst Pair (db) ELFEXT Power Sum (db) Impedanc e (Ohm) 100±15 (1-100 MHz) 100±22 ( MHz) 100±32 ( MHz) Commercial in Confidence 18 of 22
19 FIGURE 8 POWER CABLE 24/020 ORDERING CODE: FIG INNER BOX :4 Reels Version: A0 PACKAGING: 100mtr & 300mtr PALLET: 60 Reels PRODUCT NAME : Figure 8 Power cable 1.CONSTRUCTION Page: 1 / 1 NO./mm BC / BC0.20 x 24 (+0.001/-0.008) Stranded Bare copper NO./mm 6 / 1.50 (+/-0.13 ) PVC insulation 2.70 x (+/-0.15)x 5.40 (+/- 0.20) One side Black, One side Red PVC Filler PVC insulation 6.10 (+/-0.25 ) Grey PVC 2.DESIGN Black Red Item Description 1. Cond. Res. 20, Condutor DC Resistance < 2.75 Ω/ 100M 2. Insul. Res. 20, Resistance > 200 MΩ.M 3. Rated Tem Rated Voltage V *Remark: Please contact us if you have more requirements or specifications subject to change,or else in accordance with the standards.* Commercial in Confidence 19 of 22
20 SWTP-1.5 SPEAKER CABLE SPECIFICATIONS ORDERING CODE: SWTP-1.5 Version: A0 PACKAGING: 100 METRE REEL 4 REELS PER BOX PALLET: 160 ROLLS PRODUCT NAME: TP-1.5 CABLE Page: 1 / 1 1.CONSTRUCTION NO./mm 192 (+ / -8) 2 / 0.10 x ( +/ ) Stranded bare copper NO./mm 3.5 ( +/-0.35 ) Transparent PVC 3.5 x7.0 PVC 7.0 ( +/-0.60 ) insulation Shield NO./mm Non shielded NO./mm No common jacket 2.DESIGN Stranded Copper Item Description Standards C, DC Resistance < 1.48 Ω / 100 m C, Resistance > 200 MΩ 3. Rated Temperature 70 C 4. Rated Voltage 300V SWBT-1.0 SPEAKER CABLE SPECIFICATIONS ORDERING CODE: SWBT-1.0 Version: A0 PACKAGING: 100 METRE REEL 4 REELS PER BOX PALLET: 160 ROLLS PRODUCT NAME: BT-1.0 CABLE Page: 1 / 1 1.CONSTRUCTION NO./mm 90 (+/-2) 1 / T0.12 x Stranded tinned copper 1 / 0.12 x 90 ( +/ ) Stranded bare copper NO./mm 3.0 ( +/-0.18 ) 3.0 x 6.0 PVC 6.0 ( +/-0.35 ) Transparent PVC insulation Shield NO./mm Non shielded NO./mm No common jacket 2.DESIGN Stranded Copper Item Description Standards C, DC Resistance < 2.15 Ω / 100 m C, Resistance > 500 MΩ 3. Rated Temperature 70 C 4. Rated Voltage 300V Commercial in Confidence 20 of 22
21 4mm 2 SOLAR DC TWIN CABLE Commercial in Confidence 21 of 22
22 6mm 2 SOLAR DC TWIN CABLE Commercial in Confidence 22 of 22
TECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION 4 PAIR UTP CABLE CAT6 (CATEGORY 6 PLUS) Page 1 of 5 1. SCOPE This specification is based on the specifications of UL 444, ANSI/TIA/EIA-568-B,ISO/IEC 1801, UL 1685(CM) and covers
More informationPURENET-U (Part No.: U RXX2, U PXX2)
ISSUED: FEB. 3, 2010 PAGE : 1 OF 6 PURENET-U5350-00 (Part No.: U5350-04-RXX2, U5350-04-PXX2) for 4 PAIR UTP CABLES (ENHANCED CATEGORY 5E) ( Ref.: UL 444, ANSI/TIA/EIA-568B.2 & ISO/IEC 11801,IEC 61156-5
More informationCompact Module. Enhanced Category 5 FTP Cabling System
Compact Module Enhanced Category 5 performance Suitable for Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro modules and blanks Individually QA tested Easy to use
More informationDATA NETWORK TECHNOLOGY
DATA NETWORK TECHNOLOGY 236 COPPER COMPONENTS Individual. Dynamic. Adaptive. Solutions for Industry 4.0 the Internet of Things What once seemed a distant and unrealistic goal has now become business as
More informationDetailed Specifications & Technical Data
Description: 20 AWG bare copper conductor, foam polyolefin insulation, bare copper braid shield, PVC jacket. Usage (Overall) Suitable Applications: CCTV plus Audio, Pan and Tilt CCTV Control Physical Characteristics
More informationDETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, TYPE LSC5FS (INCLUDING VARIATIONS LSC5FSW, LSC5OS, AND LSC5OSW)
INCH-POUND MIL-DTL-24643/59 9 September 2005 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, TYPE LSC5FS (INCLUDING VARIATIONS LSC5FSW, LSC5OS, AND LSC5OSW) This specification is approved for use by all
More informationInside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR
Category 6 Plus Plenum Category 6 Plus Plenum has a cross web design for maximum pair separation. It features sequential footage markings that count down to zero feet -- removing the guess work concerning
More informationCompany Overview.
Company Overview About DME PROLINK by ECS Global Wire & Cable ECS was founded in North America over 30 years ago with a vision for innovation and development. Experiencing tremendous growth, we opened
More informationOutdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: Level 1/Level 2, TOUGHCable Connectors. Increase Performance. Extreme Weather-Proof
Outdoor Carrier Class Shielded Ethernet Cable Models: Level 1/Level 2, TOUGHCable Connectors Increase Performance Extreme Weather-Proof Damage Protection Extended Cable Support 1 Protect your networks
More informationAvailable in 0.75 to 16.0 sq mm. Red, Yellow, Blue, Black, White, Gray and Green (for earthing) Specification IS 694:1990
Application These cables are used for wiring domestic and coercial buildings. The multi strand flexible conductors make it ideal for concealed wiring. These cables are ideal for wiring in residential and
More informationCoaxial Cables for Broadband Communication Networks European Edition
Belden Coaxial Cables for Broadband Counication Networks European Edition Belden Coaxial Cables for Broadband Dependable Solutions in Cabling Better by design Our strategic objective is to provide our
More informationConstruction guideline
1/6 1) SUMMARY OF ABBREVIATIONS FOR CABLE CONSTRUCTION ELEMENTS MSR - : EUPEN code for INSTRUMENTATION CABLES JE - : cable for INDUSTRIAL ELECTRONICS RD - : cable for CONTROL SYSTEMS INSULATION MATERIALS:
More informationOutdoor Carrier Class Shielded Ethernet Cable. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof. ESD Damage Protection
1Datasheet Outdoor Carrier Class Shielded Ethernet Cable Models: PRO, CARRIER, Connectors Increase Performance Extreme Weatherproof ESD Damage Protection Extended Cable Support 2Datasheet Protect your
More informationAMWAJ TELECOMMUNICATION FACTORY
AMWAJ TELECOMMUNICATION FACTORY PRODUCT PROFILE (DROP WIRES & JUMPER WIRES) PO Box 325934 Riyadh 11371 Kingdom of Saudi Arabia Tel: +966 11 4004718 / 4009204, Fax: +966 11 4008027 Website: www.amwajfactory.com
More informationOutdoor Carrier Class Shielded Ethernet Cable. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof. ESD Damage Protection
1Datasheet Outdoor Carrier Class Shielded Ethernet Cable Models: PRO, CARRIER, Connectors Increase Performance Extreme Weatherproof ESD Damage Protection Extended Cable Support Datasheet Protect your networks
More informationRG-59, RG-59+2DC, UTP CAT6, SFTP CAT6
FLAT ELEVATOR CABLE RG59, RG59+2DC, UTP CAT6, SFTP CAT6 COPPER SERIES MAIN FEATURES ASTEL RG59 Lift Monitor cablescopper Series are designed and manufactured to Ultra flexibility demand of CCTV Cameras
More informationHELUKABEL CC-Link Certified Cables
Data, Network & BUS Technology HELUKABEL CCLink Certified Cables HELUKABEL provides you with all cable types for your CCLink network, approved by the CLPA organization. In addition to the classic red 3conductored
More informationFINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES - PROJECT PACKING
PRICE LIST NO: FCL/IW.11.17/05 HSN CODE:85 FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES FINOLEX PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL CABLES WITH FLAME RETARDANT PROPERTIES &
More informationData sheet chainflex CFSPECIAL.182
Ethernet (CAT5/CAT5e/GigE/PoE) Profinet (Type C) 1 / 8 Cable structure Conductor Core insulation Stranded conductor in especially bending-resistant version consisting of bare copper wires (following DIN
More informationRT/ZHLS, A-2Y(L)2Y External Telephone Cables to NR/PS/TEL/00015
RT/ZHLS, A-2Y(L)2Y External Telephone Cables to NR/PS/TEL/00015 The cables are designed primarily for trackside railway installation in non electrifi ed area. For direct burial application, brass tape
More information3M Round, Shielded/Jacketed, Disc. Wire Cable 26 AWG Solid, Twisted Pair, PVC/PVC 3560 Series
M Round, Shielded/Jacketed, Disc. Wire Cable 26 AWG Solid, Twisted Pair, PVC/PVC 560 Series Twisted pairs reduce crosstalk for balanced drive applications Dual shielding provides 5 db average shielding
More informationHELUKABEL CC-Link Certified Cables
Data, Network & Bustechnology HELUKABEL CCLink Certified Cables The HELUKABEL GmbH provides you with all cable types for your CC Link network, approved by the CLPA organization. In addition to the classical
More informationList Price w.e.f. 24th July, 2018
w.e.f. 24th July, 2018 HRFR/FR-LSH/HFFR/ PVC Insulated Industrial Cables Multicore Round PVC Cables Flat Three Core Industrial Cable for Sumersible use Telecom & Co-axial Cables LAN Cables CCTV Cables
More informationList Price w.e.f. 02nd January, 2018
w.e.f. 02nd January, 2018 HRFR/FR-LSH/HFFR/ PVC Insulated Industrial Cables Multicore Round PVC Cables Flat Three Core Industrial Cable for Sumersible use Telecom & Co-axial Cables LAN Cables CCTV Cables
More informationPCCAT5EP CAT5e SFTP Ethernet Patch Cable. PCCAT5EPX2 Dual CAT5e SFTP Figure Eight Cable. PCCAT5EUTPP CAT5e Ultra-Patch UTP Ethernet Cable
P series data cables are built to survive the toughest conditions, yet handle and coil well, again and again and again. They have been exhaustively developed, tested and re-tested. When data transmission
More informationCables de Comunicaciones Zaragoza. CW1601 Approval application.
1. GENERAL INFORMATION 1.1 LIST OF CONTENTS Cables de Comunicaciones Zaragoza. CW1601 Approval application. 1. General Information 1.1 List of Contents 1.2 Contractors Name 1.3 Test report 1.4 Product
More informationCaledonian Cables Ltd
Caledonian Motor Connection Cable Caledonian Cables Ltd s 1 Addison Addison Motor Connection Cable Company Profile Caledonian. established in 1978.offers one of the most complete lines of fiber and copper
More informationMar08 Rev A
Product Specification Category 5e, 4 UTP, 24 AWG Undercarpet Cable 108-2091 17Mar08 Rev A 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for Category 5e, 100
More informationO Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation
Product Classification E 2 O E2O540JCASS-24CT 24CT MICFIBR-12.7MB DUCT E 2 O Coaxial/Fiber/Microduct Hybrid Buried Cable E 2 O is a solution that enables service providers the ability to bridge HFC networks
More informationCables for Railway Signalling Applications General Requirements
Discipline: Engineering (Signalling) Category: Procedure Cables for Railway Signalling Applications General Requirements ESA-11-01 Applicability ARTC Network Wide Primary Source ESA-02-01 Document Status
More informationSafeX110 Single Core Flexible Tinned Copper Cable
LSZH 110 C Flexible SafeX110 Single Core Flexible Tinned Copper Cable Application: Wiring of switchboards, control, general wiring, instrumentation and communication systems. Used where low smoke, zero
More informationShipboard and Offshore Cables
Shipboard and Offshore Cables 7 Table of Contents Shipboard and Offshore Cables Page Introduction 7.2 Audio, Control and Instruentation Cables 7.3 LSNH/FRNC 7.3 Broadband Coaxial Cables 7.4 CATV Cables,
More informationMATERIAL STANDARD FOR CABLES AND WIRES
MATERIAL STANDARD FOR CABLES AND WIRES CONTENTS : PAGE No. 1. SCOPE... 2 2. SERVICE CONDITIONS... 2 3. REFERENCES AND STANDARDS... 2 4. UNITS... 3 5. CABLE DESIGN AND CONSTRUCTION... 3 5.1 Applicable Cable
More informationMineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths
Datasheet ENGLISH Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths High temperature, rugged, flexible Pt100 probe Suitable
More informationNominal Core OD Materials. Conductor (stranding) Diameter Nom. DCR
C O A X I A L C A B L E S 6.72 50 Oh Coax Lengths 30 AWG Stranded (7x38).012 Silver-coated Copper-covered Steel Silver-coated Copper Braid Shield TFE Teflon Insulation White FEP Jacket 200 C 83265 100
More informationTechnical Specification for PVC Insulated Low Voltage Neutral Screened Copper Cable
Ergon Energy Corporation Limited Technical Specification for PVC Insulated Low Voltage Neutral Screened Copper Cable ETS03-01-05 Specification ETS03-01-05 Ver 4 Contents 1. Purpose and Scope... 1 2. References...
More informationENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 15 2006 (Formerly IPS SP 100) Specification for Trunk, Feeder and Distribution Coaxial Cable NOTICE The Society
More informationType 1 Machine Cable. Oxygen free tinned annealed copper wire interwoven with high tensile poly-yarn
Mining Cable Type 1 Machine Cable Application: Typically used for interconnection of control boxes or motors on non-mobile or fixed apparatus. Used when exposure to heat is not an issue and where added
More informationENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead
Datasheet Platinum Resistance Pt100 Sheathed Thin Film Strip Sensor 2 wire sensor sheathed in a thin stainless steel shim body ideal for surface measurement ENGLISH Sheathed Pt100 element in a thin, flat
More informationloop 0.60 mh/km 0.65 mh/km RCCY031/032 /KS1 RCCY031/032 /NS mh/km 0.70 mh/km RCCY033/034 /KS1 RCCY033/034 /NS1
Drawings Models RCCY031, RCCY032, RCCY033, RCCY034 Coriolis Mass Flow and Density Meter Remote Cable Specification: Li2Y(St)/CY 3x2 AWG24 + 1x3 AWG20, pair/triple shielded; pair/triple twisted; overall
More informationcatalog Copper Wires
catalog Copper Wires ASWire Aerial Service Wire Self Supporting Multi-pair Pair Count 1-18P Multi-pair, self-supporting Aerial Service Wires (ASW) are used for subscriber lines in exchange plant; single-pair
More informationH-FLEX CABLES 10/2017
10/2017 H-FLEX CABLES CONTENTS H-FLEX PWR PUR 0,6/1kV...2 H-FLEX PWR C-PUR 0,6/1kV...6 H-FLEX CTL PUR 250V...10 H-FLEX CTL C-PUR 250V...12 H-FLEX INS PUR 250V...14 H-FLEX INS C-PUR 250V...16 TECHNICAL
More informationProduct Specification. Category 6 System (Channel), 4 UTP, 24 AWG Undercarpet Cable. 06Nov08 Rev A 1. SCOPE. 1.1.
Product Specification 108-2374 06Nov08 Rev A Category 6 System (Channel), 4 UTP, 24 AWG Undercarpet Cable 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for
More informationPlatinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing
Datasheet ENGLISH Platinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing Pt100 Patch Sensor (100 Ω Ohms @ 0
More informationENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead
ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead (Image shows 4 wire) Pt1000 element to IEC 751 Class B 2 wire configuration Temperature range -50 C to + 200 C Pt1000
More informationSTANDARD FOR. BROADBAND TWISTED PAIR CABLE AIRCORE, POLYOLEFlN INSULATED, COPPER CONDUCTOR TECHNICAL REQUIREMENTS
STANDARD FOR BROADBAND TWISTED PAIR CABLE AIRCORE, POLYOLEFlN INSULATED, COPPER CONDUCTOR TECHNICAL REQUIREMENTS Published By INSULATED CABLE ENGINEERS ASSOCIATION, INC. Post Office Box 1568 Carrollton,
More information3M Round, Shielded/Jacketed, Flat Cable.050" 28 AWG Stranded, Mass Terminatable, PVC/PVC 3659 Series
M Round, Shielded/Jacketed, Flat Cable.050" 28 AWG Stranded, Mass Terminatable, PVC/PVC 659 Series Round construction permits easier routing 28 AWG wire on.050 inch pitch permits mass termination to broad
More informationSpecification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.
Spec. No. GO 5821-4361Rev.2 Issued date : July 13, 2005 Revised 1 date : April 29, 2015 Revised 2 date : February 19, 2016 Specification FOR 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated
More informationCeramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code
Datasheet Platinum Resistance Pt100 Tubular Ceramic Insert Elements with tail wires 2 or 4 wire with choice of Teflon or nickel/glassfibre insulated tail wires up to 450mm long ENGLISH 237-1635 237-1641
More informationPt100 (100 0 C) to IEC 751, Class B, 4 wire 3.0, 4.0, 4.5 or 6.0mm diameter 316 stainless steel sheath.
Datasheet Platinum Resistance Thermometer Pt100 Industrial Sensor Probe, Class B Available in 3.0, 4.0, 4.5 or 6.0mm diameter x Various probe lengths ENGLISH Multipurpose Pt100 Probe to IEC751 Class B,
More informationContent HYBRID AND SPECIAL CABLES G 2 NEW NEW NEW NEW. page. Applications... G/3. Construction examples of special cables
Hybrid and Special Cables HYBRID AND SPECIAL CABLES Content Applications................................................................................ /3 page Construction examples of special cables
More informationDETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, TYPE LS3SWU (INCLUDING VARIATION LS3SWUS)
INCH-POUND 11 July 2011 USED IN LIEU OF MIL-DTL-24643/36F 01 October 2009 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, TYPE LS3SWU (INCLUDING VARIATION LS3SWUS) This specification is approved
More informationIntroduction. Railway Cables
Railway Cables Introduction Railway Cables Plant Kapfenberg-Einöd Pengg Kabel GmbH is an Austrian cable manufacturer and a member of the german Wilms group with two plants in Styria. We have two sites,
More informationPlatinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves
ENGLISH Datasheet Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves Pt100 Autoclave & steriliser drain temperature probe For use to monitor the fluid
More informationDatasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths
Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths ENGLISH Duplex PRT s with two independent PT100 detectors inside tip of probe. This
More informationTI 20 PVC TI 20 INSULATED TELEPHONE WIRE
TI 20 PVC TI 20 INSULATED TELEPHONE WIRE Standard: Nominal voltage: Temperature range - fixed laying: Cable Structure: Application: Packing: 2x0,5 0,4 2,6 3,6 7,2 2x0,6 0,4 2,8 5,2 9,1 2x0,8 0,4 3,2 9,2
More informationENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with DIN B Head
ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with DIN B Head With stainless steel plug (no thread) Pt100 probe with DIN B terminal head Class B, 4 wire connection Various
More informationINTERNATIONAL STANDARD
INTENATIONAL STANDAD IEC 60708 First edition 2005-06 Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath eference number IEC 60708:2005(E) Not for esale Publication numbering
More informationIndustrial Cable for Factory Automation
Industrial Cable for Factory Automation Line up Multi core & multi pair cables for high flexure part. Heat bonded flat cables for high flexure part. Multi core PVC cables for fixed part. Large size PVC
More informationCOMMUNICATIONS CABLING SECTION COMMUNICATIONS CABLING PART 1 - GENERAL
13686.00 COMMUNICATIONS CABLING 271513-1 1.1 RELATED SECTIONS SECTION 27 1513 COMMUNICATIONS CABLING PART 1 - GENERAL A. Drawings and general provisions of the Contract, including General and Supplementary
More informationSpecifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)
ENGLISH Datasheet Platinum Resistance Pt100 Wire-Wound Detector Elements Pt100 platinum resistance thermometer elements in a choice of sizes single & dual element Pt100 elements to IEC 60751 Class A or
More informationTECHNICAL SPECIFICATION ALANTEK OPTICAL FIBER FIG8 SERIES FTTH DROP CABLE
TECHNICAL SPECIFICATION ALANTEK OPTICAL FIBER FIG8 SERIES FTTH DROP CABLE 1. GENERAL DESCRIPTION 1.1 SCOPE This specification covers the design and performance requirements for the supply of optical fiber
More informationOverall Length
CABLE DRAWING: POSEIDON SCIENTIFIC INSTRUMENTS PTY LTD 17 QUEEN VICTORIA ST, FREMANTLE WA 6160. PHONE (08) 9430 6639 FAX (08) 9335 4650 MWA-3004 DRAWING TITLE: ASC2 to SBC(ASC2) I2C Control Cable DRAWING
More information11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES
11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Page 1.0 SCOPE
More information150 mm. 1/8 BSPP brass male compression fitting with locknut included
ENGLISH Datasheet Platinum Resistance PT100 Flat Tip Probe 4mm diameter x 150mm long 2 wire with 1 metre flying lead, complete with 1/8 BSP compression fitting & locknut 4mm 25mm 5.5/6mm(max) 150 mm General
More informationENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)
ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm) Pt100 Elements, Thin Film (100 Ohm) Pt100 elements to IEC751 Class A,
More informationReeling Cables www.sab-worldwide.com CONTENT page The Company....................................................................................................... 2 DR 717 P Highflex 300/500 V.........................................................................................
More informationData sheet chainflex CF887
1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Filling: Plastic yarns 4. Core insulation: Mechanically high-quality, especially low-capacitance
More informationPlatinum Resistance Thermometer Pt100 Precision Probe - High accuracy platinum resistance thermometer probe, 6mm diameter x 250mm
Datasheet ENGLISH Platinum Resistance Thermometer Pt100 Precision Probe - High accuracy platinum resistance thermometer probe, 6mm diameter x 250mm Precision Pt100 sensor offering high accuracy over the
More informationContacts for Full Duplex Ethernet Link
8D Series Twinax & Quadrax Contacts Contacts for Full Duplex Ethernet Link Twinax and Quadrax contacts with robust MIL-DTL-38999 compliant screw coupling system for networks and high vibration environments.
More informationJAMES MONROE. WIRE & CABLE CORPORATION ETT Traveling Cable Hoistway Cable Compensating Cable Stationary Communications Cable ELEVATOR CABLES
WIRE & CABLE CORPORATION ETT Traveling Cable Hoistway Cable Compensating Cable Stationary Communications Cable ELEVATOR CABLES Elevator Hoistway & Traveling Cables... Designed for high performance and
More informationComparison of BS 5308, PAS 5308 and BS EN
Comparison of BS 5308, PAS 5308 and BS EN 50288 Scope BS 5308 Part 1: 1986- Instrumentation Cables Part 1. Specification for Polyethylene Insulated Cables (withdraw, superseded by BS EN 50288-7) BS 5308
More informationTECHNICAL SPECIFICATION ALANTEK OPTICAL FIBER FTTH DROP CABLE
TECHNICAL SPECIFICATION ALANTEK OPTICAL FIBER FTTH DROP CABLE 1. GENERAL DESCRIPTION 1.1 SCOPE This specification covers the design and performance requirements for the supply of optical fiber cable which
More information10-SDMS-02 SPECIFICATIONS FOR BARE COPPER CONDUCTORS
SPECIFICATIONS FOR BARE COPPER CONDUCTORS This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Page 1.0 SCOPE 3 2.0 CROSS REFERENCES 3 3.0 APPLICABLE
More informationENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument
Datasheet ENGLISH Platinum Resistance Thermometer Pt100 Outdoor/Cold Store Temperature Sensors IP67 Weatherproof Housing, 4 wire single or dual element, or 4-20mA option Weatherproof IP67 rated wall mounting
More informationMEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]
[6.35/11kV Copper XLPE Three-Core HDPE Sheathed] APPLICATION Mostly used as feeder electric cable for power distribution network such as power supply station, substation, switching system etc. They are
More informationBUS CABLES. Content. IBL 600 PVC Interbus-Loop cable... E/11. S IBL 605 PUR Interbus-Loop cable for cable tracks... E/11
Bus Cables BUS CABLS Content page Applications... /5-6 Interbus-S cables remote bus cables IBS 612 PVC Interbus-S cable for indoor and outdoor installation... /7 IBS 617 PVC Interbus-S cable with UL recognition...
More informationSPECIFICATION FOR FRLS POWER CABLES
SPECIFICATION FOR FRLS POWER CABLES 1.0 SCOPE This specification cover the technical requirements of design, manufacture, testing and delivery to site of Power Cables of 1100V grade with FRLS PVC Sheathed,
More informationSingle core conductor BETAtherm 145
Internet: www.synflex.de Single core conductor BETAtherm 145 Description BETAtherm 145 is a flexible low-voltage cable with UL recognition consisting of a tinned copper stranded wire and insulated with
More information26/35kV Copper XLPE Insulation Electric Cable
26/35kV Copper XLPE Insulation Electric Cable Specifications 1.1~35kv XLPE insulated power cable 2.Standard: IEC,VDE,BS,UL,AS/NZS Black PVC sheath XLPE insulated armored copper power cable YJV22 YJV32
More informationENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting
ENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting RJT unions (Ring Joint Type) are often referred to as a standard union. The compromise of an O-ring style gasket
More information12/21/2018 WHAT S NEW SINCE What's New Since SPEC BOOK 2018 SPEC BOOK 2018 SPEC BOOK WHAT S NEW SINCE 2014
CHAPTER 2 STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS 2545.1B & 2565.1B QUALIFICATION OF WORKERS The provisions of 1802 are hereby supplemented with the following: Signal and Lighting Certification:
More informationSTANDARD FOR BROADBAND BURIED SERVICE WIRE, FILLED, POLYOLEFIN INSULATED, COPPER CONDUCTOR TECHNICAL REQUIREMENTS. Published By
STANDARD FOR BROADBAND BURIED SERVICE WIRE, FILLED, POLYOLEFIN INSULATED, COPPER CONDUCTOR TECHNICAL REQUIREMENTS Published By INSULATED CABLE ENGINEERS ASSOCIATION, INC. Post Office Box 1568 Carrollton,
More informationSECTION BACKBONE CABLING SPECIAL NOTE: (REMOVE FROM FINAL DOCUMENTATION)
SECTION 271400 BACKBONE CABLING SPECIAL NOTE: (REMOVE FROM FINAL DOCUMENTATION) These specifications guidelines detail the intents of KCTCS for Telecommunications Infrastructure Design and Installation.
More informationArmoured Instrumentation Cables to BS7917
Armoured Instrumentation Cables to BS1 Fire Resistant, Pairs/Triples - Collectively Screened. Low Smoke Zero Halogen TAC, MGT, EPR, SCRN, ZH, GSWB, SW 0/0V Application Control and instrumentation cable
More informationConductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.
37-105VFD MMV-VFD Power Cable Three : kv - 15kV 133% Level Rated 90 C s (3) Soft annealed flexible stranded tinned copper per IEEE 150 Table 11. Extruded thermosetting 90 C Ethylene Propylene Rubber (EPR),
More informationPV Solar Wiring Solutions
Priority Solar Projects Across the US 14 DISTRIBUTION CENTERS PV Solar Wiring Solutions ON TIME ACCURATE FLEXIBLE SERVICE CUSTOM SOLUTIONS Priority Capabilities: Premier Supplier of Wire & Cable Cut to
More informationContent. Festoon 715 P PUR cable for flexible application in festoon systems... G/21
Hybrid and Special Cables HYBRID AND SPECIAL CABLES Content 2 page Applications... /3 Construction examples of special cables: CAN-Bus cable... /4 Profibus-DP cable... /5 Coupling cable... /6 Interbus
More informationTest Report No.: Page 2 of 35
Test Report No.: 50093959 001 age 2 of 35 Test Report AS/NZS 5000.1:2005 including amendment 1 Electric cables olymeric insulated for working voltages up to 0.6/1kV Test item particulars: 1C 4mm 2 to 16
More informationAUDIO & VIDEO CABLES
AUDIO & VIDEO CABLES Speaker Wire AUDIO & VIDEO CABLES 2 Conductor 4 Conductor Commercial Grades Heavy Duty and Professional Grades Home Theater Oxygen Free Outdoor Audio Direct Burial Grades 10 AWG including
More informationDRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)
EDC3 (5239) P3 Mini-Grid Systems DRAFT TANZANIA STANDARD Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV) TANZANIA BUREAU OF STANDARDS TBS 2017 First Edition 2017 Table of Contents
More information11-SDMS-01 REV. 03 ( )
11-SDMS-01 REV. 03 (19-07-2018) SPECIFICATION FOR LOW-VOLTAGE POWER AND CONTROL CABLES Saudi Electricity Company 1. SCOPE... 3 2. CROSS REFERENCES TO OTHER SEC STANDARDS... 3 3. APPLICABLE CODES AND STANDARDS...
More informationPOSEIDON SCIENTIFIC INSTRUMENTS PTY LTD 17 QUEEN VICTORIA ST, FREMANTLE WA PHONE (08) FAX (08) CAB-0XXX (SALEM CODE)
POSEIDON SCIENTIFIC INSTRUMENTS PTY LTD 17 QUEEN VICTORIA ST, FREMANTLE WA 6160. PHONE (08) 9430 6639 FAX (08) 9335 4650 CABLE DRAWING: CAB-0XXX (SALEM CODE) DRAWING TITLE: ASC1 to SBC(ASC1) I2C Control
More informationFour Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable
Edition Nº: 9 THE ISRAEL ELECTRIC CORPORATION LTD. Specification No. NPS-76 for Four Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable for Rated Voltage U0/U = 0.6/1.0
More informationEngineering Data for Copper and Aluminum Conductor Electrical Cables
2018 Edition Engineering Data for Copper and Aluminum Conductor Electrical Cables THE OKONITE COMPANY Okonite Cables...A higher Standard! The Okonite Company, 2018 Okonite Cables Table of Contents SECTION
More informationContent. PV1-F Halogen-free cable for photo-voltaic systems... G/11. PV1-F dual Halogen-free twin cable for photo-voltaic systems...
Hybrid and Special Cables HYBRID AND SPECIAL CABLES Content page Applications... /3 Construction examples of special cables: CAN-Bus cable... /4 Profibus-DP cable... /5 Coupling cable... /6 Interbus Hybrid
More informationWill accommodate up to 35 conductors while maintaining separation required to withstand instrumentation voltages
H.0 Accessories Introduction Description Accessories is the product classification given by CeramTec for miscellaneous hardware that is used to connect, terminate, install, or isolate Ceramaseal products.
More informationGMRT. Mini-Breakout Cables (Distribution) Mobile, Tactical Indoor/ Outdoor, Heavy Duty A/I-VQ(ZN)11Y(ZN)11Y Improved Rodent Protection
GMRT Mini-Breakout Cables (Distribution) Mobile, Tactical Indoor/ Outdoor, Heavy Duty A/I-VQ(ZN)11Y(ZN)11Y Improved Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count
More informationINSTRUMENTATION, CONTROL AND THERMOCOUPLE CABLES
Conducting Value INSTRUMENTATION, CONTROL AND THERMOCOUPLE CABLES 400/7 ISO 900:08 Certificate No. CS-249 MANAGEMENT SYSTEMS Assessed to ISO 900:08 Cert/LPCB ref. 27 GOST ISO 900- (ISO 900:08) certification
More information15 Pin DSUB - MALE 15 Pin DSUB - FEMALE 9 Pin DSUB - MALE 9 Pin DSUB - FEMALE
Last Revised: 6 Oct 07 Description: This data sheet show our range of high quality appliance cables, such as signal cables (VGA / DVI / DisplayPort (DP)), Touchscreen and power cables. These are either
More information