Content. PV1-F Halogen-free cable for photo-voltaic systems... G/11. PV1-F dual Halogen-free twin cable for photo-voltaic systems...

Size: px
Start display at page:

Download "Content. PV1-F Halogen-free cable for photo-voltaic systems... G/11. PV1-F dual Halogen-free twin cable for photo-voltaic systems..."

Transcription

1 Hybrid and Special Cables

2 HYBRID AND SPECIAL CABLES Content page Applications... /3 Construction examples of special cables: CAN-Bus cable... /4 Profibus-DP cable... /5 Coupling cable... /6 Interbus Hybrid cable for the automotive industry... /7 Control cable for the automotive industry... /8 C A 883 Ö Twisting and torsion connection cable... /9 Applications for halogen-free cable for photo-voltaic systems... /10 PV1-F Halogen-free cable for photo-voltaic systems... /11 PV1-F dual Halogen-free twin cable for photo-voltaic systems... /12 PV Wire Halogen-free cable for photo-voltaic systems (UL)... /13 PV1-F with UL Halogen-free cable for photo-voltaic systems (UL)... /14 NEW NEW NEW C Lift Lift control cable with sisal center as suspension unit... /15 C Lift ST Lift control cable with steel center as suspension unit... /16 H05VVH6-F PVC Flat cables... /17 H07VVH6-F PVC Flat cables... /18 NEW NEW 2 DR 717 P Highflex Reeling cable... /19 DR 718 CP Highflex Reeling cable with overall copper screen... /20 DR 721 P Reeling cable... /21 NEW DR 720 P Highflex Reeling cable... /22 Spreader 722 Control cable hoisting cages in crane systems... /23 Festoon 715 P PUR cable for flexible application in festoon systems... /24 MR 460 Control cable with numbered cores and fibre-reinforced PUR sheath... /25 NEW NEW NEW Enquiry form for special cables... /26 Harnessed cables... /27 B helix cables... /28 Constuction details for helix cables... /29 : especially for use in rail vehicles

3 HYBRID AND SPECIAL CABLES Applications n Technical problems often arise that can not be solved properly by standard cables. Being a customer of S Bröckskes, you have the right to get the best solution. Therefore, we are pleased being your specialist for special cables. No matter whether a cable of our standard range is to be modified or a completely new cable is to be constructed: we will work together with you intensively in order to realise your requests and needs. Anyway, you will profit from our variedness and flexibility, that besides our wide standard product range of cables count among the special strengths of our company. We produce nearly every type of special cable for you already with minimum quantities of 500 m, in certain dimensions already 100 m - exactly according to your individual construction demands. Please give us your requested details, such as: n conductor material n number of cores n cross sections n colours n outer diameter n flexibility n low and high temperature resistance n materials n types of screening n combined cables n technical specifications n optical waveguide n number of fibres n POF (polymeric optical fibres) n Of course, we also fulfil other parameters than the above-mentioned. Your requests are always most important and our highly motivated team will meet them applying our comprehensive know-how. By this means you will be able to improve the efficiency of your machines. n Are you interested in a special solution? You only need to note the requested parameters in the forms shown on pages /26 and /29. Or you contact directly our sales team that is supported by sales representatives in many parts of Europe. 3 n You will find further information about the safe application of cables on pages N/28-38

4 HYBRID AND SPECIAL CABLES Example: CAN-Bus cable Halogen-free combined cable with overall copper screen item no cross 2 x 2 x 0.50 mm 2 + sections 4 x 0.50 mm x 0.50 mm 2 4 Conductor: tinned copper strands, fine wires with reference to DIN VDE 0812 Insulation: A 231 thermoplastic material and 02YI1 acc. to DIN VDE 0819 part 103 (for 2 x 0.50 mm 2 ) Screen: tinned copper braid, optical coverage 85% Sheath material: A 263 thermoplastic material Marking: SAB BRÖCKSKES D-VIERSEN SO. SABIX CAN-BUS-LEITUN Peak operating voltage: max. 450 V Testing voltage: core/core 1000 V (DC) core/screen 1500 V (DC) Min. bending radius flexible application: 10 x d fixed laying: -40/+70 C flexible application: -30/+70 C Halogen-free: acc. to DIN VDE 0472 part 815 and IEC Fire performance: no flame propagation acc. to IEC EN category C resp. D (see page N/20) flame retardant and self-extinguishing acc. to IEC and EN Characteristic impedance: acc. to VDE 0472 part 516 at 1 Mhz: 120 Ω ± 10% (CAN-Bus) Image attenuation acc. to VDE 0472 part 515 at 1 Mhz: constant: approx. 1.5 db/100 m (CAN-Bus) Mutual capacitance: acc. to VDE 0472 part 504 test method: approx. 15 nf/km (CAN-Bus) Oil resistance: acc. to EN section 10 and VDE 0473 part section 10 acc. to RoHS-guideline 2002/95/E as well as harmful substances: efstoffv appendix IV-no. 24, see page N/14

5 HYBRID AND SPECIAL CABLES Example: Profibus-DP cable Halogen-free Profibus-DP cable with ralve control for use in cable tracks item no cross 2 x 0,34 mm 2 + sections: 4 x 1,5 mm 2 Halogen-free Profibus-DP cable with seperate current supply for use in cable tracks item no cross 2 x 0,34 mm 2 + sections: 3 x 1,00 mm 2 5 Conductor: bare copper strands, fine wires Insulation : 0,34 mm 2 : cellular PE 1,00 mm 2 /1,50 mm 2 :TPE Stranding: Profibus twisted pairwise, pairs and conductors twisted in layers Screen Profibus: Sheath material: braid of tinned copper round wires PUR, TMPU acc. to DIN VDE 0282 part 10 Sheath colour: redlilac (RAL 4001) Marking SAB BRÖCKSKES D-VIERSEN item no : S PB 634 2x0,34 mm 2 + 4x1,5 mm 2 C Marking SAB BRÖCKSKES D-VIERSEN item no : S PB 634 2x0,34 mm 2 + 3x1,0 mm 2 C Peak operating voltage: item no : 100 Veff. item no : max. 350 V Testing voltage: core/core 1500 V core/screen 1000 V Min. bending radius flexible application: 12 x d fixed laying: -40/+80 C flexible application: -40/+80 C Halogen-free: acc. to DIN VDE 0472 part 815 and IEC Oil resistance: TMPU acc. to DIN VDE 0282 part 10 and HD Characteristic impedance: acc. to VDE 0472 part 516 at 3-20 MHz: 150 Ω ± 15 Ω acc. to RoHS-guideline 2002/95/E as well as harmful substances: efstoffv appendix IV-no. 24, see page N/14 item no. no. of nominal max. copper cable ohmic conductors cross-section outer-ø figure weight resistance at 20 C mm 2 mm kg/km ca. kg/km max. Ω/km ,34 12,0 78, ,0 4 1,50 13,3 item no. no. of nominal max. copper cable ohmic conductors cross-section outer-ø figure weight resistance at 20 C mm 2 mm kg/km ca. kg/km max. Ω/km ,34 10,6 48, ,0 3 1,00 19,5

6 HYBRID AND SPECIAL CABLES Example: Coupling cable Torsion able connecting cable item no cross 33 x 1.5 mm 2 + sections 3 x 10.0 mm x (2 x 1.5) mm 2 6 Conductor: Insulation: Screen: special copper, fine wires TPE spezial copper braid, optical coverage 85% Sheath material: special PUR Nominal voltage: 1,50 mm 2 : Uo/U 0,6/1,0 kv 10,0 mm 2 : Uo/U 1,8/3,0 kv Testing voltage: core/core 1,50 mm 2 : 4000 V, 10,0 mm 2 : V core/screen 1,50 mm 2 : 2000 V, 10,0 mm 2 : 6000 V Min. bending radius flexible application: 10 x d fixed laying: -50/+90 C flexible application: -40/+90 C acc. to RoHS-guideline 2002/95/E as well as harmful substances: efstoffv appendix IV-no. 24, see page N/14

7 HYBRID AND SPECIAL CABLES Example: Interbus Hybrid cable for the automotive industry PUR interbus hybrid cable pairwise with copper wrapping for flexible application item no cross 4 x 1,0 mm 2 + sections: 5 x 2 x 0,25 mm x 1,0 mm 2 PVC interbus hybrid cable pairwise with copper wrapping for fixed laying item no cross 4 x 1,00 mm 2 + sections: 5 x 2 x 0,25 mm x 1,00 mm 2 7 Conductor: Insulation: bare copper strands, fine wires 0.25 mm 2 : PE 1.00 mm 2 : TPE Colour code: 0.25 mm 2 : colored acc. to DIN mm 2 : black, blue, red, brown, green/yellow Screen: pairs wrapped with tinned copper wires, optical coverage min. 90% Sheath material: : special PUR : PVC Sheath colour: redlilac (RAL 4001) Peak operating voltage: max. 350 V Testing voltage: core/core 1700 V (AC) core/screen 1000 V (AC) core/core 2500 V (DC) core/screen 1500 V (DC) Min. bending radius: 7.5 x d fixed laying: -40/+70 C -5/+70 C flexible application: -40/+70 C -30/+70 C acc. to RoHS-guideline 2002/95/E as well as harmful substances: efstoffv appendix IV-no. 24, see page N/14

8 HYBRID AND SPECIAL CABLES Example: Control cable for the automotive industry Special PUR connection cable with numbered cores and overall copper screen item no cross 23 x 1.0 mm 2 + sections (2 x 1.0 mm 2 ) D + 1 x 1.0 mm 2 8 Conductor: Insulation: Colour code: Screen: Inner sheath: tinned copper strands TPE white cores with consecutive numbers acc. to EN and a green-yellow earth wire wrapped with tinned copper wires TPE Outer sheath: special PUR Peak operating voltage: max. 350 V Testing voltage: core/core 1500 V core/screen 1000 V Min. bending radius: 7.5 x d fixed laying: -50/+90 C flexible application: -40/+90 C acc. to RoHS-guideline 2002/95/E as well as harmful substances: efstoffv appendix IV-no. 24, see page N/14

9 RAILWAY CABLE C A 883 Ö twisting and torsion connection cable the use in qfor rail vehicles, e. g. bogies and boxes also possible without earth wire Conductor: Insulation: Colour code: Stranding: Inner sheath: Sheath material: tinned copper strands, acc. to IEC EN 60228, DIN VDE 0295 class 6 TPE black cores with consecutive numbers acc. to DIN VDE green-yellow earth wire from 3 cores in layers A PUR Marking: SAB BRÖCKSKES D-VIERSEN A A 833 Ö dimension C Nominal voltage: Uo/U 300/500 V Testing voltage: core/core 2000 V Min. bending radius fixed laying: 4 x d flexible application: 6 x d fixed laying: -50/+85 C flexible application: -40/+85 C Torsion angle: ± 15 Halogen-free: acc. to DIN VDE 0472 part 815 and IEC Fire performance: flame retardant and self-extinguishing acc. to IEC EN UV resistance: good Ozone resistance: Oil resistance: good good Weather resistance: good acc. to RoHS-guideline 2002/95/E as well as harmful substances: efstoffv appendix IV-no. 24, see page N/14 9 item no. no. of cores largest outer-ø copper cable x cross section single wire ± 5% figure weight n x mm 2 ø mm mm kg/km kg/km x 1,50 0,16 8,1 28, x 1,50 0,16 8,4 43, x 1,50 0,16 9,0 57, x 1,50 0,16 10,4 100, x 1,50 0,16 15,2 259,2 417 item no. no. of cores largest outer-ø copper cable x cross section single wire ± 5% figure weight n x mm 2 ø mm mm kg/km kg/km x 2,50 0,16 9,7 75, x 2,50 0,16 10,5 100, x 2,50 0,16 11,5 125, x 2,50 0,16 12,2 176, x 4,00 0,16 13,6 192,0 335 Other dimensions and colours are possible on request.

10 CABLE FOR PHOTOVOLTAIC SYSTEMS PV1-F cable For almost 60 years S BRÖCKSKES has been a leading manufacturer of cable technique. Our company s philosophy bases on the development and permanent improvement of product quality. d BRÖCKSKES D-VIERSEN PV1-F 4,0 mm 2 C 10 4 n halogen-free n UV-resistant n fulfills DKE draft AK * Application: Due to our permanent striving for innovative products in line with our efforts for environmental protection, we have focussed our attention on renewable energy. As a consequence the PV1-F cable has been our la test development. Already in 2008 about 1.7 million solar systems were installed with upward trend. Every day the sun delivers an energy quantity going beyond eighty times the consumption of ermany. Furthermore, this source is free of charge and will be inexhaustible within the next billions of years. In future solar energy will replace conven tional energy sources such as oil or gas. The PV1-F cable fulfills the requirements of cables for photovoltaic systems acc. to the DKE draft AK * and is particularly used as connection cable in photovoltaic systems. The cable is suitable for various climatic conditions such as outdoor use as well as for fixed laying in dry, damp and wet rooms. Our solar cable is approved by the DKE draft AK * for a maximum temperature at the conductor up to +120 C and suitable as electrical equipment of protection class II. *as at

11 CABLE FOR PHOTOVOLTAIC SYSTEMS PV1-F halogen-free cable for photovoltaic systems The requirements acc. to the DKE draft AK * are fulfilled. B C VDE-RE.-Nr PV1-F 4,0 mm 2 VDE-RE.-Nr TÜVSüd-Bauart geprüft B Marking for PV1-F : SAB BRÖCKSKES D-VIERSEN PV1-F 4,0 mm 2 VDE-RE.-Nr TÜVSüd-Bauart geprüft B C Conductor : tinned copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 Primary insulation: Color code primary insulation: Secondary insulation: Color code secondary insulation: A solar see table below A solar see table below Outstanding features: fulfills DKE draft AK * halogen-free no flame propagation flame retardant and self-extinguishing up to +120 C weather resistant sunlight resistance with improved fire performance expected service life: up to 25 years very good resistance against acids and alkaline solutions ammonia resistance absence of marten attractants Nominal voltage Uo/U: Testing voltage: Min. bending radius Ø 12 mm: Ø > 12 mm: 0,6/1 kv (AC) 6500 V (AC) 3 x d 4 x d for ambient temperature: up to +90 C maximum temperature at the conductor: +120 C for installation: -30/+120 C fixed laying: -40/+120 C short circuit: +250 C VDE-RE.-no as well as TÜV SÜD type tested B : Halogen-free : without hydrogen chloride acc. to EN , without fluorine content acc. to EN Corrosiveness of in compliance with IEC conflagration gases: EN VDE part no development of corrosive conflagration gases Fire performance: flame retardant and self-extinguishing acc. to IEC EN Sunlight resistance: Weather resistance: yes very good Ozone resistance: acc. to EN Ammonia resistance: very good acc. to RoHS-guideline 2002/95/E as well as harmful substances: efstoffv appendix IV-no. 24, see page N/14 11 item no. nominal outer-ø copper cable cross-section max. figure weight mm 2 mm kg/km kg/km ,50 5,0 14, ,50 5,4 24, ,00 6,0 38, ,00 6,9 57, ,0 8,9 96, ,0 10,3 153, ,0 12,5 240, ,0 13,9 236,0 463 Other dimensions are possible on request. Marking for primary insulation and secondary insulation Primary insulation / secondary insulation 33 black / black 38 black / red 32 black / blue 83 red / black 88 red / red 22 blue / blue 23 blue / black Other colours are possible on request. suitable for protecting class II 4 *as at

12 CABLE FOR PHOTOVOLTAIC SYSTEMS PV1-F dual halogen-free twin cable for photovoltaic systems The requirements acc. to the DKE draft AK * are fulfilled. B PV1-F 2x6,0 mm 2 VDE-RE.-Nr TÜVSüd-Bauart geprüft B C Marking for PV1-F dual : SAB BRÖCKSKES D-VIERSEN PV1-F 2x6,0 mm 2 VDE-RE.-Nr TÜVSüd-Bauart geprüft B C +120 C VDE-RE.-Nr Conductor : tinned copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 Primary insulation: Color code primary insulation: Secondary insulation: Color code secondary insulation: A solar black / red or black / blue A solar black Outstanding features: fulfills DKE draft AK * halogen-free no flame propagation flame retardant and self-extinguishing up to +120 C weather resistant sunlight resistance with improved fire performance expected service life: up to 25 years very good resistance against acids and alkaline solutions ammonia resistance absence of marten attractants Nominal voltage Uo/U: Testing voltage: Min. bending radius Ø 12 mm: Ø > 12 mm: 0,6/1 kv (AC) 6500 V (AC) 3 x d 4 x d for ambient temperature: up to +90 C maximum temperature at the conductor: +120 C for installation: -30/+120 C fixed laying: -40/+120 C short circuit: +250 C VDE-RE.-no as well as TÜV SÜD type tested B : Halogen-free : without hydrogen chloride acc. to EN , without fluorine content acc. to EN Corrosiveness of in compliance with IEC conflagration gases: EN VDE part no development of corrosive conflagration gases Fire performance: flame retardant and self-extinguishing acc. to IEC EN Sunlight resistance: Weather resistance: yes very good Ozone resistance: acc. to EN Ammonia resistance: very good acc. to RoHS-guideline 2002/95/E as well as harmful substances: efstoffv appendix IV-no. 24, see page N/14 item no. no. of nominal outer-ø copper cable conductors cross-section approx. figure weight mm 2 mm kg/km kg/km ,00 6,0 x 11,9 76, ,00 6,9 x 13,8 115, ,0 8,7 x 17,4 192,0 323 Other dimensions are possible on request. Marking for primary insulation and secondary insulation Primary insulation / secondary insulation 83 red / black 23 blue / black Other colours are possible on request. suitable for protecting class II 4 *as at

13 CABLE FOR PHOTOVOLTAIC SYSTEMS PV Wire halogen-free cable for photovoltaic systems Photovoltaic Wire Service- Entrance Cable wet sunlight-resistant -40 C ( U L) Service-Entrance Cable Type USE-2 600V Single Conduct SAB BRÖCKSKES D-VIERSEN Conductor : tinned copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 and UL standard 758 table UL 1581 table 20.1 Primary insulation: A 285 Color code primary insulation: see table below Secondary insulation: A 285 Color code secondary insulation: see table below Outstanding features: UL Subject 4703 PV Wire UL 854 USE-2 halogen-free flame retardant and self-extinguishing weather resistant sunlight resistance very good resistance against acids and alkaline solutions connection cable for photovoltaic modules acc. to NEC Section (A) ammonia resistance absence of marten attractants Marking for PV Wire : 12 AW ( U L) Photovoltaic Wire 600V 90 C dry 90 C wet sunlight-resistant -40 C ( U L) Service-Entrance Cable Type USE-2 600V Single Conductor C Nominal voltage: 600 V (AC) Testing voltage: 3000 V (AC) Min. bending radius Ø 12 mm: 3 x d Ø > 12 mm: 4 x d for ambient temperature: -40 C/+90 C Halogen-free : without hydrogen chloride acc. to EN , without fluorine content acc. to EN Corrosiveness of in compliance with IEC conflagration gases: EN VDE part no development of corrosive conflagration gases. Fire performance: flame retardant and self-extinguishing acc. to IEC EN and (UL) FT1 Sunlight resistance: yes Weather resistance: very good Ozone resistance: acc. to EN Ammonia resistance: very good acc. to RoHS-guideline 2002/95/E as well as harmful substances: efstoffv appendix IV-no. 24, see page N/14 13 item no. AW outer-ø copper cable max. figure weight mm kg/km kg/km ,6 38, ,1 57, ,9 84,5 151 Other dimensions are possible on request. Marking for primary insulation and secondary insulation Primary insulation / secondary insulation 33 black / black 23 blue / black 63 white / black 83 red / black Other colours for the primary insulation possible on request.

14 B CABLE FOR PHOTOVOLTAIC SYSTEMS PV1-F with UL +120 C 0 C ( U L) Service-Entrance Cable Type USE-2 600V Single Conductor C halogen-free cable for photovoltaic systems VDE-RE.-Nr Marking for PV1-F with UL : SAB BRÖCKSKES D-VIERSEN PV1-F 4,0 mm 2 VDE-RE.-Nr TÜVSüd-Bauart geprüft B AW12 (UL) Photovoltaic Wire 600V 90 C dry 90 C wet sunlight-resistant -40 C ( U L) Service-Entrance Cable Type USE-2 600V Single Conductor C Photovoltaic Wire Service- Entrance Cable The requirements acc. to the DKE draft AK * are fulfilled. 14 Conductor : tinned copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 and UL standard 758 table UL 1581 table 20.1 Primary insulation: A solar Color code primary insulation: see table below Secondary insulation: Color code secondary insulation: A solar see table below Outstanding features: fulfills DKE draft AK * UL Subject 4703 PV Wire UL 854 USE-2 halogen-free no flame propagation flame retardant and self-extinguishing up to +120 C weather resistant sunlight resistance with improved fire performance expected service life: up to 25 years very good resistance against acids and alkaline solutions connection cable for photovoltaic modules acc. to NEC Section (A) ammonia resistance absence of marten attractants Nominal voltage Uo/U: 0,6/1 kv (AC) (UL): 600 V (AC) Testing voltage: 6500 V (AC) (UL): 3000 V (AC) Min. bending radius Ø 12 mm: 3 x d Ø > 12 mm: 4 x d VDE-RE.-no as well as TÜV SÜD type tested B : for ambient temperature: up to +90 C (UL): -40 C/+90 C maximum temperature at the conductor: +120 C for installation: -30/+120 C fixed laying: -40/+120 C short circuit: +250 C Halogen-free : without hydrogen chloride acc. to EN , without fluorine content acc. to EN Corrosiveness of in compliance with IEC conflagration gases: EN VDE part no development of corrosive conflagration gases Fire performance: flame retardant and self-extinguishing acc. to IEC EN and (UL) FT1 Sunlight resistance: yes Weather resistance: very good Ozone resistance: acc. to EN Ammonia resistance: very good acc. to RoHS-guideline 2002/95/E as well as harmful substances: efstoffv appendix IV-no. 24, see page N/14 item no. nominal outer-ø copper cable cross-section mm figure weight mm 2 kg/km kg/km ,00 6,8 38, ,00 7,5 57,6 114 suitable for protecting class II Other dimensions are possible on request. 4 Marking for primary insulation and secondary insulation Primary insulation / secondary insulation 33 black / black 83 red / black 23 blue / black 63 white / black Other colours are possible on request. *as at

15 LIFT CABLES with improved fire performance C Lift Lift control cable with sisal cord as suspension unit D-VIERSEN SABIX Lift 24 x 1,0 m Marking for SABIX Lift : SAB BRÖCKSKES D-VIERSEN SABIX Lift 24 x 1,0 mm 2 C Our halogen-free lift cables are used whenever there are highest safety requirements, especially in public buildings and institutions as for example department stores, hospitals, railway and airport institutions, etc. Conductor: Insulation: Colour code: Strain relief: Stranding: Wrapping: Supporting braid: bare copper strands, acc. to IEC 60228, EN 60228, DIN VDE 0295 class 6 special A black cores with consecutive numbers acc. to EN and green-yellow earth wire sisal cord sisal cord as core, optimized twisting of the conductors in layers netting tape on each layer with overlap wrapping special torsion protecting net Sheath material: thermoplastic special elastomer Nominal voltage: Testing voltage: Uo/U 300/500 V Min. bending radius: 15 x d fixed laying: -40/+90 C flexible application: -30/+90 C conductor/conductor 2000 V Halogen-free: acc. to DIN VDE 0472 part 815 and IEC Fire performance: no flame propagation acc. to IEC EN category C resp. D (see page N/20) Suspended height: up to 60 m acc. to RoHS-guideline 2002/95/E as well as harmful substances: efstoffv appendix IV-no. 24, see page N/14 Product advantages: halogen-free long service life elevated economic efficiency flame retardant and self-extinguishing 15 item no. no. of cores x medium copper cable ohmic cross section outer-ø figure weight resistance at 20 C n x mm 2 ø mm kg/km kg/km max. Ω/km x 1,00 11,8 67, , x 1,00 22,0 230, , x 1,00 23,3 288, ,5 Further dimensions or special constructions on request. q Possible on request! with total copper braiding with different conductor and sheath colours Note: Please pay attention to the installation instructions on page N/27! You will find a life cycle test C Lift on page N/22!

16 LIFT CABLES Highest hanging lengths C Lift ST Lift control cable with steel center as suspension unit KSKES D-VIERSEN SABIX Lift ST 24 x 1,0 mm 2 C Marking for SABIX Lift ST : SAB BRÖCKSKES D-VIERSEN SABIX Lift ST 24 x 1,0 mm 2 C Our halogen-free lift cables are used whenever there are highest safety requirements, especially in public buildings and institutions as for example department stores, hospitals, railway and airport institutions, etc. Conductor: Insulation: Colour code: Strain relief: Stranding: Wrapping: Supporting braid: bare copper strands, acc. to IEC 60228, EN 60228, DIN VDE 0295 class 6 special A black cores with consecutive numbers acc. to EN and green-yellow earth wire steel rope in the center steel rope as core, optimized twisting of conductors in layers netting tape on each layer with overlap wrapping special torsion protecting net Sheath material: thermoplastic special elastomer Nominal voltage: Testing voltage: Uo/U 300/500 V Min. bending radius: 15 x d fixed laying: -40/+90 C flexible application: -30/+90 C conductor/conductor 2000 V Halogen-free: acc. to DIN VDE 0472 part 815 and IEC Fire performance: no flame propagation acc. to IEC EN category c resp. D (see page N/20) Suspended height: up to 200 m acc. to RoHS-guideline 2002/95/E as well as harmful substances: efstoffv appendix IV-no. 24, see page N/14 16 Product advantages: halogen-free highest hanging lengths long service life flame retardant and self-extinguishing item no. no. of cores x medium copper cable ohmic cross section outer-ø figure weight resistance at 20 C n x mm 2 ø mm kg/km kg/km max. Ω/km x 1,00 18,6 230, , x 1,00 20,9 288, ,5 Further dimensions or special constructions on request. q Possible on request! with total copper braiding with different conductor and sheath colours Note: Please pay attention to the installation instructions on page N/27! You will find a life cycle test C Lift on page N/22!

17 PVC FLAT CABLES H05VVH6-F BRÖCKSKES D-VIERSEN wvdeswhars H05VVH6-F 240,7 Marking for PVC Flat cable : SAB BRÖCKSKES D-VIERSEN wvdeswhars H05VVH6-F 240,75 mm 2 C Conductor: bare copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 Insulation: Colour code: Stranding: PVC black with white numbers and green-yellow earth wire cores parallel side by side in groups Sheath material: PVC Nominal voltage: Uo/U 300/500 V Min. bending radius: 10 x d fixed laying: -40 C/+70 C flexible application: -40 C/+70 C Fire performance: flame retardant and self-extinguishing acc. to IEC EN Oil resistance: acc. to internal standard, see page N/13 acc. to RoHS-guideline 2002/95/E as well as harmful substances: efstoffv appendix IV-no. 24, see page N/14 item no. no. of cores largest dimension copper cable x cross section single wire width x height figure weight n x mm 2 ø mm approx. mm kg/km kg/km x 0,75 0,21 17,8 x 4,2 43, x 0,75 0,21 25,8 x 4,2 64, x 0,75 0,21 39,1 x 4,2 86, x 0,75 0,21 43,5 x 4,2 115, x 0,75 0,21 48,4 x 4,2 129, x 0,75 0,21 53,9 x 4,2 144, x 0,75 0,21 64,3 x 4,2 172, x 1,0 0,21 12,7 x 4,3 38, x 1,0 0,21 15,3 x 4,3 48, x 1,0 0,21 18,4 x 4,3 57, x 1,0 0,21 26,7 x 4,3 86, x 1,0 0,21 34,3 x 4,3 115, x 1,0 0,21 45,1 x 4,3 153, x 1,0 0,21 50,2 x 4,3 172, x 1,0 0,21 55,9 x 4,3 192, x 1,0 0,21 66,7 x 4,3 230, Other dimensions and colours are possible on request.

18 PVC FLAT CABLES H07VVH6-F KES D-VIERSEN wvdeswhars H07VVH6-F 121,5 mm 2 C Marking for PVC Flat cable : SAB BRÖCKSKES D-VIERSEN wvdeswhars H07VVH6-F 12 x 1,5 mm 2 C Conductor: bare copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 Insulation: PVC Colour code: coloured acc. to HD 308 (VDE 0293 part 308); black cores with consecutive numbers acc. to EN from 6 cores; green-yellow earth wire from 3 cores Stranding: cores parallel side by side in groups Sheath material: PVC Nominal voltage: Uo/U 450/750 V Min. bending radius: 10 x d fixed laying: -40 C/+70 C flexible application: -40 C/+70 C Fire performance: flame retardant and self-extinguishing acc. to IEC EN Oil resistance: acc. to internal standard, see page N/13 acc. to RoHS-guideline 2002/95/E as well as harmful substances: efstoffv appendix IV-no. 24, see page N/14 18 item no. no. of cores largest dimension copper cable x cross section single wire width x height figure weight n x mm 2 ø mm approx. mm kg/km kg/km x 1,50 0,26 15,3 x 5,2 57, x 1,50 0,26 25,6 x 5,2 100, x 1,50 0,26 28,6 x 5,2 115, x 1,50 0,26 41,9 x 5,2 172, x 2,50 0,26 18,3 x 5,8 96, x 2,50 0,26 50,7 x 5,8 288, x 4,00 0,31 57,4 x 6,8 460, x 6,00 0,31 22,7 x 7,3 230, x 6,00 0,31 27,5 x 7,3 288, x 10,0 0,41 35,7 x 9,3 480, x 25,0 0,41 42,5 x 12,9 960, Other dimensions and colours are possible on request.

19 REELIN CABLES DR 717 P Highflex BRÖCKSKES D-VIERSEN DR 717 P Highflex 4 2,5 mm 2 C Marking for DR 717 P Highflex : SAB BRÖCKSKES D-VIERSEN DR 717 P Highflex 4 2,5 mm 2 C Conductor: bare copper strands acc. to IEC EN 60228, VDE 0295, class 5 Insulation: special polymer Colour code: coloured acc. to HD 308 (VDE 0293 part 308); from 6 cores black cores with consecutive numbers acc. to EN 50334; green-yellow earth wire from 3 cores DMX-bus: white/brown, green/yellow IE Cat 5: white-blue/blue, white-orange/orange, white-green/green, white-brown/brown Stranding: specially adjusted layering around central suspension unit Inner sheath: PUR Supporting screen: high-tech yarn Outer sheath: PUR Outstanding features: reeling length up to 60 m high winding and unwinding strength corresponds to low voltage guideline 73/23/EW CE small outer diameter small cable weight Application: The DR 717 P Highflex is used for spring cables reels on stages and theaters Nominal voltage: Peak operating volatge: Testing voltage: Technical Data: Uo/U 300/500 V (supply conductors) item no : max. 500 V (DMX-bus) item no : max. 125 V (IE Cat 5) core/core 2000 V Current-carrying capacity: acc. to DIN VDE , see page N/33 + N/34 Min. bending radius: for laying and installation (fixed laying): 12 mm 3 x d / >12 mm 4 x d for repeated winding action (flexible): 6 x d guided on deflection pulleys (flexible): 7,5 x d item no. item no with installation: -00/+50 C fixed laying: -50/+90 C -40/+70 C -20/+60 C flexible application: -40/+90 C -40/+70 C -20/+60 C Halogen-free: acc. to DIN VDE 0472 part 815 and IEC Oil resistance: very good - TMPU acc. to DIN VDE 0282 part 10 + HD Chemical resistance: good against acids, alkalines, solvents, hydraulic liquids, etc. Fire performance: flame retardant and self-extinguishing acc. to IEC and EN Sunlight resistance: very good - enhanced due to black sheath colour Tensile strength: with reference to DIN VDE section 7.1 Mechanical the main mechanical characteristics accomplished characteristics: by the PUR outer sheath are: - high tensile strength - high tear strength - high abrasion resistance - high notch resistance harmful acc. to RoHS guideline 2002/95/E as well as substances: efstoffv appendix IV-no. 24 see page N/14 19 item no. no. of cores x outer-ø copper cable tensile min breaking cross section ± 5% figure weight strength load of n x mm 2 mm kg/km kg/km max. N suspension unit N ,50 9,7 96, ,00 11,7 153, ,00 20,9 537, ,00 23,3 768, ,00 28,3 960, ,00 13,4 230, ,00 24,3 748, ,0 17,1 384, ,0 21,3 614, , x (2 x 0,25)C 22,4 575, ,0 + 4 x 2 x 0,14 26,4 791, ,00 min. 25,0 max. 28,0 960, Other dimesnsions and colours are possible on request. Please mention the required winding length when placing the order. Note: Please pay attention to the installation instructions on page N/26

20 REELIN CABLES DR 718 CP Highflex with overall copper screen ÖCKSKES D-VIERSEN DR 718 CP Highflex 4 x 2,5 mm 2 C Marking for DR 718 CP Highflex : SAB BRÖCKSKES D-VIERSEN DR 718 CP Highflex 4 x 2,5 mm 2 C 20 Conductor: bare copper strands acc. to IEC EN 60228, VDE 0295, class 5 Insulation: special polymer Colour code: coloured acc. to HD 308 (VDE 0293 part 308); from 6 cores black cores with consecutive numbers acc. to EN 50334; green-yellow earth wire from 3 cores Stranding: specially adjusted layering around central suspension unit Inner sheath: Screen: PUR tinned copper braiding Outer sheath: PUR Outstanding features: high winding and unwinding strength small cable weight good EMC characteristics Applications: The DR 718 CP Highflex is used for spring cable reels on stages for example in theaters as well as control cable in crane arms q Technical Data: Nominal voltage: Uo/U 300/500 V Testing voltage: 2000 V Current-carrying capacity: acc. to DIN VDE , see page N/33 + N/34 Min. bending radius: for laying and installation (fixed laying): 5 x d for repeated winding action (flexible): 7,5 x d guided on deflection pulleys (flexible): 10 x d fixed laying: -50/+90 C flexible application: -40/+90 C Halogen-free: acc. to DIN VDE 0472 part 815 and IEC Fire performance: flame retardant and self-extinguishing acc. to IEC and EN Oil resistance: very good - TMPU acc. to DIN VDE 0282 part 10 + HD Chemical resistance: good against acids, alkalines, solvents, hydraulic liquids, etc. Sunlight resistance: very good - enhanced due to black sheath colour Tensile strength: with reference to DIN VDE section 7.1 Mechanical the main mechanical characteristics accomplished characteristics: by the PUR outer sheath are: - high tensile strength - high tear strength - high abrasion resistance - high notch resistance acc. to RoHS-guideline 2002/95/E as well as harmful substances: efstoffv appendix IV-no. 24, see page N/14 Also possible without inner sheath! item no. no. of cores x outer-ø copper cable tensile min breaking cross section ± 5% figure weight strength load of n x mm 2 mm kg/km kg/km max. N suspension unit N x 0,50 12,8 161, x 0,50 14,9 192, x 0,75 16,9 281, x 1,00 8,0 62, x 1,00 15,0 188, x 1,00 14,5 237, x 1,00 17,8 355, x 1,00 17,8 365, x 1,50 8,9 86, x 1,50 10,2 120, x 1,50 11,9 157, x 1,50 16,9 274, x 1,50 16,3 301, x 1,50 16,3 330, x 1,50 16,4 359, x 1,50 18,2 463, x 1,50 23,4 586, x 1,50 22,2 681, x 2,50 10,8 144, x 2,50 11,9 176, x 2,50 13,7 232, x 2,50 19,9 418, item no. no. of cores x outer-ø copper cable tensile min breaking cross section ± 5% figure weight strength load of n x mm 2 mm kg/km kg/km max. N suspension unit N x 2,50 19,5 561, x 2,50 23,6 730, x 2,50 26,8 892, x 2,50 26,1 1035, x 2,50 30,7 1353, x 2,50 32,6 1547, x 4,00 12,3 210, x 4,00 13,7 256, x 4,00 16,3 372, x 6,00 13,7 302, x 6,00 15,7 389, x 6,00 18,9 518, x 10,0 18,1 499, x 10,0 20,3 609, x 16,0 22,3 757, x 16,0 24,9 926, x 25,0 27,0 1131, x 35,0 30,8 1542, x 50,0 35,3 2147, Other dimesnsions and colours are possible on request. Please mention the required winding length when placing the order. Note: Please pay attention to the installation instructions on page N/26

21 REELIN CABLES DR 721 P BRÖCKSKES D-VIERSEN DR 721 P 12 1,5 mm Marking for DR 721 P : SAB BRÖCKSKES D-VIERSEN DR 721 P 12 1,5 mm 2 C Conductor: bare copper strands acc. to IEC EN 60228, VDE 0295, class 5 Insulation: special polymer Colour code: coloured acc. to HD 308 (VDE 0293 part 308); from 6 cores black cores with consecutive numbers acc. to EN 50334; green-yellow earth wire from 3 cores Stranding: specially adjusted layering Inner sheath: special PVC Supporting screen: high-tech yarn Outer sheath: PUR Outstanding features: good winding and unwinding strength small outer diameter small cable weight corresponds to low voltage guideline 73/23/EW CE Application: The DR 721 P is used for spring cable and motor cable reels, hoists, transport systems and farm vehicles with medium mechanical stress. Nominal voltage: Testing voltage: Technical Data: 0,6/1 kv core/corer 4000 V Current-carrying capacity: acc. to DIN VDE , see page N/33 + N/34 Min. bending radius: for laying and installation (fixed laying): 6 x d for repeated winding action (flexible): 10 x d guided on deflection pulleys: (flexible): 12 x d of the cable: fixed laying: -30/+70 C flexible: -30/+70 C Temperature resistance of primary insulation: up to +90 C Fire performance: flame retardant and self-extinguishing acc. to IEC und EN Oil resistance: very good - TMPU acc. to DIN VDE 0282 part 10 + HD Chemical resistance: very good against acids, alkaline solutions, solvents and hydraulic liquids, etc. Weather resistance: very good Sunlight resistance: very good - enhanced due to black sheath colour Tensile strength: acc. to DIN VDE section 7.1 Mechanical the main mechanical characteristics characteristics: accomplished by the PUR outer sheath are: - high tensile strength - high tear strength - high abrasion resistance - high notch resistance harmful acc. to RoHS guideline 2002/95/E as well as substances: efstoffv appendix IV-Nr. 24 see page N/14 21 item no. no. of coresx outer-ø copper cable cross section ± 5% figure weight n x mm 2 mm kg/km kg/km ,50 8,8 57, ,50 9,6 72, ,50 11,7 100, ,50 16,4 172, ,50 16,3 259, ,50 19,6 345, ,50 22,1 518, ,50 10,2 96, ,50 11,2 120, ,50 13,6 168, ,50 19,4 288, ,50 19,4 432, ,50 23,6 576,0 891 item no. no. of coresx outer-ø copper cable cross section ± 5% figure weight n x mm 2 mm kg/km kg/km ,50 26,4 864, ,00 12,4 153, ,00 14,4 230, ,00 15,6 288, ,0 17,9 384, ,0 22,4 614, ,0 25,0 768, x 25, ,00 24,2 892, x 35, ,00 28,0 1180, x 50, ,0 31,8 1728, Other dimesnsions and colours are possible on request. Please mention the required winding length when placing the order. Note: Please pay attention to the installation instructions on page N/26

22 REELIN CABLES DR 720 P Highflex D-VIERSEN DR 720 P Highflex 12 1,5 mm 2 C Marking for DR 720 P Highflex : SAB BRÖCKSKES D-VIERSEN DR 720 P Highflex 12 1,5 mm 2 C 22 Conductor: bare copper strands acc. to IEC EN 60228, VDE 0295, class 5 Insulation: special polymer Colour code: coloured acc. to HD 308 (VDE 0293 part 308); from 6 cores black cores with consecutive numbers acc. to EN 50334; green-yellow earth wire from 3 cores Stranding: specially adjusted layering around central suspension unit Inner sheath: PUR Supporting screen: high-tech yarn Outer sheath: PUR Outstanding features: path feed rate up to 120 m/min. high winding and unwinding strength small outer diameter small cable weight corresponds to low voltage guideline 73/23/EW CE Application: The DR 720 P Highflex is used for heavy appliances as for example motor cable reels hoists, transport systems, movable motors and farm vehicles with high mechanical stress. Nominal voltage: Testing voltage: Technical Data: 0,6/1 kv core/core 4000 V Current-carrying capacity: acc. to DIN VDE , see page N/33 + N/34 Min. bending radius: for laying and installation (fixed laying): 12 mm 3 x d / >12 mm 4 x d for repeated winding action (flexible): 6 x d guided on deflection pulleys (flexible): 7,5 x d fixed laying: -50/+90 C flexible application: -40/+90 C Halogen-free: acc. to DIN VDE 0472 part 815 and IEC Oil resistance: very good - TMPU acc. to DIN VDE 0282 part 10 + HD Chemical resistance: good against acids, alkalines, solvents, hydraulic liquids, etc. Fire performance: flame retardant and self-extinguishing acc. to IEC and EN Weather resistance: very good Sunlight resistance: very good - enhanced due to black sheath colour Tensile strength: acc. to DIN VDE section 7.1 Mechanical the main mechanical characteristics accomplished characteristics: by the PUR outer sheath are: - high tensile strength - high tear strength - high abrasion resistance - high notch resistance harmful acc. to RoHS guideline 2002/95/E as well as substances: efstoffv appendix IV-Nr. 24 see page N/14 item no. no. of cores x outer-ø copper cable min breaking cross section ± 5% figure weight load of n x mm 2 mm kg/km kg/km suspension unit N ,50 9,0 57, ,50 9,8 72, ,50 11,8 100, ,50 16,6 172, ,50 16,4 259, ,50 10,4 96, ,50 11,6 120, ,50 19,6 288, ,50 19,7 432, ,50 23,8 576, ,50 26,6 720, ,50 32,4 1200, item no. no. of cores x outer-ø copper cable min breaking cross section ± 5% figure weight load of n x mm 2 mm kg/km kg/km suspension unit N ,00 12,4 153, ,00 24,0 460, ,00 14,8 230, ,0 18,2 384, ,0 22,7 614, x 25, ,00 24,3 892, ,0 26,9 960, x 35, ,00 28,1 1180, ,0 31,5 1344, x 50, ,0 31,9 1728, Other dimesnsions and colours are possible on request. Please mention the required winding length when placing the order. Note: Please pay attention to the installation instructions on page N/26

23 CABLES FOR CRANE AND CONVEYOR APPLICATIONS Spreader 722 Control cable hoisting cages in crane systems BRÖCKSKES D-VIERSEN Spreader x 2,5 mm 2 C s Marking for Spreader : SAB BRÖCKSKES D-VIERSEN Spreader x 2,5 mm 2 C Conductor: Insulation: Colour code: Suspension unit: Stranding: Wrapping: Stranding: Wrapping: bare copper strands PVC black cores with consecutive numbers acc. to EN 50334; green-yellow earth wire from 3 cores Armid braided with lead, 50 m of the suspended cable are supported by a 5 times safety calculation cores are twisted to bundles with lead cord in the centre overlapping non-woven tape bundle and lead cords twisted, suspension unit in the centre overlapping non-woven tape Outer sheath: PUR Outstanding features: for hoisting cage applications high breaking load of supporting unit oil resistant weather resistant Nominal voltage: Technical Data: Uo/U 300/500 V Testing voltage: core/core 2000 V fixed laying: -20/+60 C flexible application: -20/+60 C max. allowed operating temperature at conductor: +70 C short circuit temperature at cocductor: +150 C Tensile load: max. 15 N/mm 2 x sum of all cable sections Recommended cage diameter min. 30 x d, cage dimensions: cage height approx. 45 x d Travel speed hoisting gear: max. 160 m/min. Oil resistance: very good - TMPU acc. to DIN VDE 0282 part 10 + HD Weather resistance: appropriate for applications in dry, damp and wet rooms as well as in the open-air with a very good resistance against ozone, UV radiation and humidity 23 item no. no. of cores outer-ø copper cable x cross section ± 10% figure weight n x mm 2 mm kg/km kg/km x 1,00 32,1 460, x 2,50 29,7 576, x 2,50 32,9 720, x 2,50 36,2 864, x 2,50 39,2 1008, x 2,50 41,9 1152, x 3,50 30,9 633, x 3,50 33,2 760, x 3,50 37,0 950, x 3,50 40,2 1140, Other dimesnsions and colours are possible on request. q Application: Cable for carriers for example spreaders with high mechanical stress and vertical cage operation

24 CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P : SAB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C A B BRÖCKSKES D-VIERSEN Festoon 715 P 18 x 2,5 mm 2 C Marking for Festoon 715 P : SAB BRÖCKSKES D-VIERSEN Festoon 715 P 18 x 2,5 mm 2 C 24 Conductor: bare copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 Insulation: Colour code: Stranding: Wrapping: TPE single conductor black; from 2 conductors coloured acc. to HD 308 (VDE 0293 part 308); from 6 conductors black cores with consecutive numbers acc. to EN 50334; green-yellow earth wire from 3 cores specially adjusted layering around a central suspension unit non-woven tape Sheath material: PUR Outstanding features: halogen-free high abrasion resistance small outer diameter Path feet rate in cable roller assemblies up to 240 m/min. Nominal voltage: Uo/U 0,6/1 kv Testing voltage U: 4000 V acc. to DIN VDE 0281 part 2 + HD 21.2 Min. bending radius: 6 x d Continuous tensile load: max. 15 N/mm 2 acc. to DIN VDE 0298 part 3 section 7.1 fixed laying: -50/+90 C flexible application: -40/+90 C Halogen-free: acc. to DIN VDE 0472 part IEC Oil resistance: very good - TMPU acc. to DIN VDE 0282 part 10 + HD Chem. resistance: good against acids, alkalines, solvents, hydraulic liquids etc.. Continuous flexibility: very good Weather resistance: very good acc. to RoHS-guideline 2002/95/E as well as harmful substances: efstoffv appendix IV-no. 24, see page N/14 item no. no. of cores largest outer-ø copper cable x cross section single wire ± 5% figure weight n x mm 2 ø mm mm kg/km kg/km x 1,50 0,26 7,3 43, x 1,50 0,26 7,9 57, x 1,50 0,26 8,6 72, x 1,50 0,26 10,2 100, x 1,50 0,26 12,6 172, x 1,50 0,26 15,0 259, x 1,50 0,26 17,7 345, x 1,50 0,26 18,9 432, x 2,50 0,26 8,3 72, x 2,50 0,26 9,3 96, x 2,50 0,26 10,1 120, x 2,50 0,26 12,1 168, x 2,50 0,26 15,7 288, x 2,50 0,26 17,5 432, x 2,50 0,26 21,1 576, x 2,50 0,26 22,3 720, x 4,00 0,31 10,9 153, x 6,00 0,31 12,8 230, x 10,00 0,41 15,1 288, x 10,00 0,41 16,5 384, x 10,00 0,41 18,2 480, x 16,00 0,41 8,7 153, x 16,00 0,41 18,8 460, x 16,00 0,41 20,7 614, x 16,00 0,41 23,1 768, x 25,00 0,41 10,5 240, x 25,00 0,41 24,3 960, x 25,00 0,41 27,1 1200, item no. no. of cores largest outer-ø copper cable x cross section single wire ± 5% figure weight n x mm 2 ø mm mm kg/km kg/km x 35,00 0,41 12,1 226, x 35,00 0,41 28,5 1344, x 50,00 0,41 13,5 480, x 50,00 0,41 32,1 1920, x 70,00 0,41 15,8 672, x 95,00 0,51 18,7 912, x 120,00 0,51 20,4 1152, x 150,00 0,51 22,3 1440, x 185,00 0,51 24,0 1776, x 240,00 0,51 28,1 2304, x 6, x 1,00 0,31 11,9 201, x 50, x 10,00 0,41 29,0 1728, Other dimensions and colours are possible on request. q The Festoon 715 P cable is applied for high mechanical stress. It is particulary suitable for use in cable roller assemblies.

25 CABLES FOR HIH MECHANICAL STRESS MR 460 Control cable with numbered cores and fibre-reinforced PUR sheath D-VIERSEN MR x 0,75 mm C Marking for MR : SAB BRÖCKSKES D-VIERSEN MR x 0,75 mm C Conductor: bare copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 6 Insulation: Colour code: Stranding: TPE black cores with consecutive numbers acc. to EN 50334; green-yellow earth wire from 3 cores specially adjusted layering Wrapping: non-woven tape Supporting screen: high-tech yarn Sheath material: PUR, TMPU acc. to DIN VDE 0282 part 10 + HD Sheath colour: black (similar RAL 9005) Outstanding features: halogenfree reinforced outer sheath for high mechanical stress notch resistant abrasion resistant good flexibility also at low temperatures weather resistant oil resistant good chemical resistance Sunlight resistant Nominal voltage: Uo/U 300/500 V Testing voltage: 2000 V Min. bending radius fixed laying: 5 x d flexible application: 10 x d fixed laying: -50/+90 C flexible application: -40/+90 C Halogen-free: acc. to DIN VDE 0472 part 815 and IEC Oil resistance: very good - TMPU acc. to DIN VDE 0282 part 10 + HD Chemical resistance: good against acids, alkalines, solvents, hydraulic liquids, etc. UV-resistance: very good - enhanced due to black sheath colour Mechanical the main mechanical characteristics accomplished characteristics: by the PUR outer sheath are: - high tensile strength - high tear strength - high abrasion resistance - high notch resistance - high transverse stregth acc. to RoHS-guideline 2002/95/E as well as harmful substances: efstoffv appendix IV-no. 24, see page N/14 25 item no. no. of cores largest outer-ø copper cable x cross section single wire ± 5% figure weight n x mm 2 ø mm mm kg/km kg/km x 0,50 0,16 6,4 14, x 0,50 0,16 6,7 19, x 0,50 0,16 7,3 24, x 0,50 0,16 8,2 33, x 0,50 0,16 9,8 57, x 0,50 0,16 11,2 86, x 0,50 0,16 13,2 120, x 0,75 0,16 7,0 21, x 0,75 0,16 7,4 28, x 0,75 0,16 8,0 36, x 0,75 0,16 9,0 50, x 0,75 0,16 10,9 86, x 0,75 0,16 12,9 129, x 0,75 0,16 15,2 180, x 1,00 0,16 7,4 28, x 1,00 0,16 7,9 38, x 1,00 0,16 8,5 48, x 1,00 0,16 9,9 67,2 137 item no. no. of cores largest outer-ø copper cable x cross section single wire ± 5% figure weight n x mm 2 ø mm mm kg/km kg/km x 1,00 0,16 11,9 115, x 1,00 0,16 13,6 172, x 1,00 0,16 16,6 240, x 1,50 0,16 8,0 43, x 1,50 0,16 8,6 57, x 1,50 0,16 9,3 72, x 1,50 0,16 10,9 100, x 1,50 0,16 13,1 172, x 1,50 0,16 15,5 259, x 1,50 0,16 18,4 360, x 2,50 0,16 9,8 72, x 2,50 0,16 10,5 96, x 2,50 0,16 11,5 120, x 2,50 0,16 13,5 168, x 2,50 0,16 16,7 288, x 2,50 0,16 19,4 432, x 2,50 0,16 23,4 600,0 868 Other dimensions and colours are possible on request. q For unprotected usage with high mechanical stress e.g. in the forest and agriculture industry!

26 HYBRID AND SPECIAL CABLES Enquiry for special cable to S BRÖCKSKES mbh & Co. K Fax: +49 / / Phone: +49 / / Company/Name: Please calculate a non-binding offer based on the following data: r We need a cable for the following application: r Dimension: r Quantity: r Requested delivery time: 26 r r r fixed laying: flexible application: r Special ambient influences: B BRÖCKSKES mbh & Co. K refrather Straße b Viersen ERMANY info@sab-broeckskes.de #

27 HYBRID AND SPECIAL CABLES Cable harnessing n Due to the good co-operation with our customers we get continuously new ideas. Therefore, S Bröckskes has enlarged the product range by the field of cable and wire harnessing. No matter whether you need cable looms, assembled single conductors or cables - S Bröckskes offers a wide range of products, especially adjusted to your demands and specifications. There are many possibilities in use of assembled cables. Some of these applications are in the car manufacturing industry, machine and industrial plant construction, control engineering, manufacturing of house hold appliances. Connection possibilities of the large variety of connectors and sling parts offer efficient and cost saving solutions. The variety of possible uses of materials that are processed by S Bröckskes at present: 27 n PUR n TPE n Besilen (silicone) n PVC (polyvinyl chloride) n A (halogen-free) n ETFE, FEP, PFA n Rubber n Special materials (fibre glass, Kapton, Stex etc.) also offer a wide range of applications in industry. n Please do not hesitate to contact our specialists, who will help you with an individual advice fitting to your application.

Reeling Cables www.sab-worldwide.com THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control technique as well as in cable production have made a one man business

More information

The Company by Peter Bröckskes sen. an independent, middle sized company

The Company by Peter Bröckskes sen. an independent, middle sized company The Company DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control technique as well as in cable production have made a one man business a company with nearly 500 staff

More information

BUS CABLES. Content. IBL 600 PVC Interbus-Loop cable... E/11. S IBL 605 PUR Interbus-Loop cable for cable tracks... E/11

BUS CABLES. Content. IBL 600 PVC Interbus-Loop cable... E/11. S IBL 605 PUR Interbus-Loop cable for cable tracks... E/11 Bus Cables BUS CABLS Content page Applications... /5-6 Interbus-S cables remote bus cables IBS 612 PVC Interbus-S cable for indoor and outdoor installation... /7 IBS 617 PVC Interbus-S cable with UL recognition...

More information

CONTENT. Robot cables. page. < The company < W - worldwide < Certifications < Clientele / supplier numbers... 6

CONTENT. Robot cables. page. < The company < W - worldwide < Certifications < Clientele / supplier numbers... 6 CONTENT page < The company............................................................................... 3 < W - worldwide...............................................................................

More information

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics ENERGY PROTOLON(SMK) LWL (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics Technical Data Type Type designation Approvals/ standards Application PROTOLON (SMK) LWL (N)TSKCGEWÖU DIN

More information

Construction guideline

Construction guideline 1/6 1) SUMMARY OF ABBREVIATIONS FOR CABLE CONSTRUCTION ELEMENTS MSR - : EUPEN code for INSTRUMENTATION CABLES JE - : cable for INDUSTRIAL ELECTRONICS RD - : cable for CONTROL SYSTEMS INSULATION MATERIALS:

More information

H-FLEX CABLES 10/2017

H-FLEX CABLES 10/2017 10/2017 H-FLEX CABLES CONTENTS H-FLEX PWR PUR 0,6/1kV...2 H-FLEX PWR C-PUR 0,6/1kV...6 H-FLEX CTL PUR 250V...10 H-FLEX CTL C-PUR 250V...12 H-FLEX INS PUR 250V...14 H-FLEX INS C-PUR 250V...16 TECHNICAL

More information

Cables for Drag Chains

Cables for Drag Chains HELUKABEL Products are available from MARYLAND METRICS P.O. Box 21 Owings Mills, MD 211 USA web: http://mdmetric.com ph: (4)35-3130 (00)3-30 fx: (4)35-32 (00)72-9329 email: sales@mdmetric.com RFQ form:

More information

Single core conductor BETAtherm 145

Single core conductor BETAtherm 145 Internet: www.synflex.de Single core conductor BETAtherm 145 Description BETAtherm 145 is a flexible low-voltage cable with UL recognition consisting of a tinned copper stranded wire and insulated with

More information

PHOTOVOLTAIC CABLES. Energy and Fiber Optical Cables for Solar Energy Systems.

PHOTOVOLTAIC CABLES. Energy and Fiber Optical Cables for Solar Energy Systems. PHOTOVOLTAIC CABLES Energy and Fiber Optical Cables for Solar Energy Systems. As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of

More information

etwork etwork-/ethernet-/foc-cable

etwork etwork-/ethernet-/foc-cable etwork etwork-/ethernet-/foc-cable Chainflex eadycable Network-/Ethernet-/FOC-cable Cable type Jacket Page CFLG.6G Gradient fiber glass cable TPE 226 CFLG.12G Gradient fiber glass cable TPE 228 CAT5 Ethernet

More information

U.V resistance UL Sunlight Resistance. Flame retardant IEC

U.V resistance UL Sunlight Resistance. Flame retardant IEC Cable for underground power distribution and subtransmission. Description Application Underground power distribution and subtransmission. As transformer feeders in substations. In power plants, industrial

More information

FLAMABILITY TESTS FOR ELECTRICAL CABLES

FLAMABILITY TESTS FOR ELECTRICAL CABLES Tests on electric and optical fibre cables under fire conditions Description E 60332-1-2 E 60332-2-2 acc. to IEC 60332-1-2 acc. to IEC 60332-2-2 Tests for flame Tests for flame propagation for a single

More information

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072. 37-105VFD MMV-VFD Power Cable Three : kv - 15kV 133% Level Rated 90 C s (3) Soft annealed flexible stranded tinned copper per IEEE 150 Table 11. Extruded thermosetting 90 C Ethylene Propylene Rubber (EPR),

More information

Armoured Instrumentation Cables to BS7917

Armoured Instrumentation Cables to BS7917 Armoured Instrumentation Cables to BS1 Fire Resistant, Pairs/Triples - Collectively Screened. Low Smoke Zero Halogen TAC, MGT, EPR, SCRN, ZH, GSWB, SW 0/0V Application Control and instrumentation cable

More information

HELUKABEL CC-Link Certified Cables

HELUKABEL CC-Link Certified Cables Data, Network & Bustechnology HELUKABEL CCLink Certified Cables The HELUKABEL GmbH provides you with all cable types for your CC Link network, approved by the CLPA organization. In addition to the classical

More information

Cables & Accessories for Wind Turbines 2013 /

Cables & Accessories for Wind Turbines 2013 / Cables & Accessories for Wind Turbines 13 / www.helukabel.com Welcome to HELUKABEL The logistic centre Heingen HELUKABEL is a global manufacturer and supplier of cables, wires & accessories. Founded in

More information

Compact Module. Enhanced Category 5 FTP Cabling System

Compact Module. Enhanced Category 5 FTP Cabling System Compact Module Enhanced Category 5 performance Suitable for Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro modules and blanks Individually QA tested Easy to use

More information

Hose protection. Hose protection. Edition: 02/2008 Catalogue 1

Hose protection. Hose protection. Edition: 02/2008 Catalogue 1 Hose protection Edition: 02/2008 Catalogue 1 12 Note All the information in this catalogue is based on the standards applicable at the time of publication and the regulations of the employers liability

More information

Instrumentation Cables

Instrumentation Cables Instrumentation Cables Product Catalogue Factories and Regional Offices Tai Sin Electric Limited 24 Gul Crescent Jurong Town Singapore 62953 Tel: (+65) 6672 9292 Fax: (+65) 686 4084 E-Mail: sales@taisin.com.sg

More information

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths Datasheet ENGLISH Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths High temperature, rugged, flexible Pt100 probe Suitable

More information

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code Datasheet Platinum Resistance Pt100 Tubular Ceramic Insert Elements with tail wires 2 or 4 wire with choice of Teflon or nickel/glassfibre insulated tail wires up to 450mm long ENGLISH 237-1635 237-1641

More information

Comparison of BS 5308, PAS 5308 and BS EN

Comparison of BS 5308, PAS 5308 and BS EN Comparison of BS 5308, PAS 5308 and BS EN 50288 Scope BS 5308 Part 1: 1986- Instrumentation Cables Part 1. Specification for Polyethylene Insulated Cables (withdraw, superseded by BS EN 50288-7) BS 5308

More information

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead Datasheet Platinum Resistance Pt100 Sheathed Thin Film Strip Sensor 2 wire sensor sheathed in a thin stainless steel shim body ideal for surface measurement ENGLISH Sheathed Pt100 element in a thin, flat

More information

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed] [6.35/11kV Copper XLPE Three-Core HDPE Sheathed] APPLICATION Mostly used as feeder electric cable for power distribution network such as power supply station, substation, switching system etc. They are

More information

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal) ENGLISH Datasheet Platinum Resistance Pt100 Wire-Wound Detector Elements Pt100 platinum resistance thermometer elements in a choice of sizes single & dual element Pt100 elements to IEC 60751 Class A or

More information

Platinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing

Platinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing Datasheet ENGLISH Platinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing Pt100 Patch Sensor (100 Ω Ohms @ 0

More information

Industrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable

Industrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable Corning Cable 229.5012 Industrial LSZH Loose Tube, Gel-Free, Corning Cable Systems Industrial LSZH Fiber Optic Cables are designed for industrial building backbones and harsh environments atypical of traditional

More information

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm) ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm) Pt100 Elements, Thin Film (100 Ohm) Pt100 elements to IEC751 Class A,

More information

2 Pfg 1169/ Requirements for cables for use in photovoltaic-systems

2 Pfg 1169/ Requirements for cables for use in photovoltaic-systems 2 Pfg 1169/08.2007 Requirements for cables for use in photovoltaic-systems Jede Art der Vervielfältigung, auch auszugsweise, nur mit Genehmigung Seite 1 von 23 Contents Seite Foreword...3 1 Scope...3 2

More information

Fibre optic cables CTC LSZH 1,2kN

Fibre optic cables CTC LSZH 1,2kN CTC LSZH,kN CTC LSZH,kN - Universal, Metallfree, Central Tube Cable. Light-weight, non-metallic, universal central tube cable (indoor/outdoor) with small diameter, rodent protected, longitudinal water-protected,

More information

ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead

ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead (Image shows 4 wire) Pt1000 element to IEC 751 Class B 2 wire configuration Temperature range -50 C to + 200 C Pt1000

More information

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths ENGLISH Duplex PRT s with two independent PT100 detectors inside tip of probe. This

More information

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation Product Classification E 2 O E2O540JCASS-24CT 24CT MICFIBR-12.7MB DUCT E 2 O Coaxial/Fiber/Microduct Hybrid Buried Cable E 2 O is a solution that enables service providers the ability to bridge HFC networks

More information

Technical Data Sheet. Cellular Buffers CONTENTS. Order number 018xxxx-xxxY

Technical Data Sheet. Cellular Buffers CONTENTS. Order number 018xxxx-xxxY 08xxxx-xxxY CONTENTS Page General information...2 2 Examples of application...2 3 Conductix-Wampfler standard cellular buffer quality...2 4 Quality degrees...3 5 Construction...4 5. With base plate...4

More information

WHITE PAPER Flex Life vs Flexibility

WHITE PAPER Flex Life vs Flexibility WHITE PAPER Flex Life vs Flexibility The design criteria for both flex life and flexibility is the same but the properties and application of the elements can be vastly different. The design elements are

More information

Cables for Railway Signalling Applications General Requirements

Cables for Railway Signalling Applications General Requirements Discipline: Engineering (Signalling) Category: Procedure Cables for Railway Signalling Applications General Requirements ESA-11-01 Applicability ARTC Network Wide Primary Source ESA-02-01 Document Status

More information

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 70mm 2 FLEXIBLE TINNED COPPER CONDUCTOR 3.3kV EPR INSULATED WITHOUT METALLIC SCREEN

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 70mm 2 FLEXIBLE TINNED COPPER CONDUCTOR 3.3kV EPR INSULATED WITHOUT METALLIC SCREEN Engineering Specification Electrical Networks MESP 030000-04 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 70mm 2 FLEXIBLE TINNED COPPER CONDUCTOR 3.3kV EPR INSULATED WITHOUT METALLIC SCREEN Version: 1 Issued:

More information

Electrical Insulating Tapes

Electrical Insulating Tapes Electrical Insulating Tapes Energy, Mining, Industrial and Contractors applications LV and MV electrical jointing and termination applications Adhesive or Self-amalgamating UV resistant Cold and weather

More information

Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves

Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves ENGLISH Datasheet Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves Pt100 Autoclave & steriliser drain temperature probe For use to monitor the fluid

More information

NTechnical Data. General Information - C... N/2. General Information - PUR... N/3. General Information - PVC... N/4

NTechnical Data. General Information - C... N/2. General Information - PUR... N/3. General Information - PVC... N/4 Technical Data General Information - C... /2 General Information - PUR... /3 General Information - PVC... /4 General Information - Besilen (Silicone)... /5 Abbreviations... /6 Insulation and sheath material

More information

Cable solutions for Automation & Drives

Cable solutions for Automation & Drives www.leoni-industrial-solutions.com Cable solutions for Automation & Drives The Quality Connection Issue 11/2016 All FieldLink products are permanently enhanced for our customers. Therefore this brochure

More information

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0 REVISION NO. 0 NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0 PAGE NO. 1 OF 24 DATE OF ISSUE (MONTH/YEAR) TOTAL NO. OF PAGES (Including cover

More information

Glossary Of Terms M-1

Glossary Of Terms M-1 Glossary Of Terms ANSI - American National Standards Institute. Armor - A sheath, serving, braid or other layer of metal applied over a cable to increase its mechanical protection. ARR - Association of

More information

ENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting

ENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting ENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting RJT unions (Ring Joint Type) are often referred to as a standard union. The compromise of an O-ring style gasket

More information

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR Category 6 Plus Plenum Category 6 Plus Plenum has a cross web design for maximum pair separation. It features sequential footage markings that count down to zero feet -- removing the guess work concerning

More information

HEKAPLAST. PE-HD twin wall cable ducts and cable protection pipes for underground installation. Corrugated and Twin Wall Pipes of Plastics

HEKAPLAST. PE-HD twin wall cable ducts and cable protection pipes for underground installation. Corrugated and Twin Wall Pipes of Plastics HEKAPLAST PE-HD twin wall cable ducts and cable protection pipes for underground installation HEGLER HEKAPLAST III/ HEKAPLAST: Twin wall cable ducts or cable protection pipes to DIN 696, manufactured from

More information

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category.

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category. Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category. Superastic Flex Extra sliding for extra easy installation. Superastic Flex cables are ideal for those who want to save installation

More information

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) DELHI METRO RAIL CORPORATION LIMITED DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) SPECIFICATION NO. DMES- T/0018/ DMRC-E-TR-CABLE-2 SPECIFICATIONS FOR 33 kv CABLES FOR ELEVATED AND Issued on: Date Stage

More information

Flat polyvinyl chloride sheathed flexible cables

Flat polyvinyl chloride sheathed flexible cables BRITISH STANDARD BS EN 50214:2006 Flat polyvinyl chloride sheathed flexible cables The European Standard EN 50214:2006 has the status of a British Standard ICS 29.060.20 BS EN 50214:2006 National foreword

More information

*** Supercedes: BECO E and COM , , & ***

*** Supercedes: BECO E and COM , , & *** 7/27/09 Page 1 of 9 R5 *** Supercedes: BECO E2.9-27.4 and COM 1-0696, 2-0196, & 5-0385 *** 1.0 Scope #2 AWG to 1000 KCMIL CONCENTRIC NEUTRAL JACKETED CABLES RATED 5-35 kv These Specifications cover single

More information

Introduction. Railway Cables

Introduction. Railway Cables Railway Cables Introduction Railway Cables Plant Kapfenberg-Einöd Pengg Kabel GmbH is an Austrian cable manufacturer and a member of the german Wilms group with two plants in Styria. We have two sites,

More information

Your Partner for Custom Interconnectivity Solutions. ISO 9001 AS9100C ISO ISO Qualified

Your Partner for Custom Interconnectivity Solutions. ISO 9001 AS9100C ISO ISO Qualified Your Partner for Custom Interconnectivity Solutions ISO 9001 AS9100C ISO 13485 ISO 17025 Qualified LEMO Precision Custom Connection Solutions The Original Push-Pull Connector Seven Decades of Expertise

More information

Engineering Data for Copper and Aluminum Conductor Electrical Cables

Engineering Data for Copper and Aluminum Conductor Electrical Cables 2018 Edition Engineering Data for Copper and Aluminum Conductor Electrical Cables THE OKONITE COMPANY Okonite Cables...A higher Standard! The Okonite Company, 2018 Okonite Cables Table of Contents SECTION

More information

Amphenol Spectra-Strip

Amphenol Spectra-Strip 161 Series Fiber Optic Cable for Harsh Environments 1 are subject to change without notice. Introduction Amphenol Corporation is a world leader in harsh environment Interconnect systems. The Spectra-Strip

More information

Additional and supplementary information on membranes and membrane keypads. Additional and supplementary information on projectivecapacitive

Additional and supplementary information on membranes and membrane keypads. Additional and supplementary information on projectivecapacitive Scope of the FT quality guidelines: All details apply to unmounted keypads or systems with touch/membrane. Deviations from these quality guidelines are permitted following agreement with the customer.

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more information please call 1-800-Belden1 See Put-ups and Colors Related Documents: No.10 for Fiber Optic Cables.pdf Cable Characteristics: DESCRIPTION: 4 to 36 optical fibers, Gel filling loose tubes

More information

Heatshrink & Cable Repair Solutions

Heatshrink & Cable Repair Solutions PAGE EASI-SHRINK HEATSHRINK SLEEVING ZERO-HALOGEN HEATSHRINK SLEEVING DR-25 HEATSHRINK TUBING KYNAR HIGH TEMPERATURE HEATSHRINK HEATSHRINK KITS ADHESIVE LINED HEATSHRINK SLEEVING 347-348 349-350 351 352

More information

Data Sheet 110kV TD123II dry type outdoor termination

Data Sheet 110kV TD123II dry type outdoor termination 3 Data Sheet 110kV TD123II dry type outdoor termination 1. Product Description: 3M 110kV TD123II dry type outdoor termination meets requirement of test and product according to IEC60840 and GB11017.3,

More information

Custom-Designed Clamps. Machined Versions. Online Configurator for Custom-Designed Clamps A56.

Custom-Designed Clamps. Machined Versions.  Online Configurator for Custom-Designed Clamps A56. Custom-Designed Clamps Machined Versions Custom-designed clamping systems for pipes, tubes, hoses, cables and other components according to customer`s specifications or based on developments, made of thermoplastics,

More information

Cable Jointing Manual. Jointing Procedures. Module 18. Concentric Cables

Cable Jointing Manual. Jointing Procedures. Module 18. Concentric Cables Cable Jointing Manual Jointing Procedures Module 18 Concentric Cables Version: 1.0 Date of Issue: June 2008 Author: Richard Summers Job Title: Cables Specialist Approver: Keith Nutter Job Title: Network

More information

SoliTek PV Modules INSTALLATION MANUAL

SoliTek PV Modules INSTALLATION MANUAL SoliTek PV Modules INSTALLATION MANUAL Version: 16 10 14 According to: IEC 61215 IEC 61730 For: SOLID PRO 300-310 W p SOLID PRO 250-260 W p SOLID PRO 150-160 W p Thank you for choosing SoliTek panels.

More information

Cable junction boxes with intrinsic fire resistance and insulation integrity

Cable junction boxes with intrinsic fire resistance and insulation integrity PASSION FOR POWER. Reliable power supply, even in the event of fire Cable junction boxes with intrinsic fire resistance and insulation integrity E90 For more information see www.hensel-electric.de Planning

More information

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES 11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Page 1.0 SCOPE

More information

FP30112WHITE100 Heat Shrink TW Tubing 100' Spool

FP30112WHITE100 Heat Shrink TW Tubing 100' Spool FP30112WHITE100 Heat Shrink TW Tubing Minnesota Mining (3M) Catalog Number FP30112WHITE100 Manufacturer Minnesota Mining (3M) Description Tubing, Heat; ; 600 V; Cable Size 1/2 Inch; Thin Wall; Shrink Temperature

More information

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT CEB SPECIFICATION 005-1: 2012 P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS PAGE 1. Scope 03

More information

Welding Accessories

Welding Accessories Welding Accessories www.airliquide.ca 1-800-817-7697 Welding Accessories BLUESHIELD Welding Cables Blueshield Welding Cables: Excellent flexibility (stays flexible at -50 C) Abrasion resistant Oil, solvent

More information

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor TABLE OF CONTENTS SECTION SUBJECT PAGE I. SCOPE...1 II. APPLICABLE DOCUMENTS...1 III. CONDUCTOR...2 IV. SEPARATOR...2 V. INSULATION...2 A. Physical Properties...2 B. Electrical Properties...3 C. Qualification

More information

catalog Copper Wires

catalog Copper Wires catalog Copper Wires ASWire Aerial Service Wire Self Supporting Multi-pair Pair Count 1-18P Multi-pair, self-supporting Aerial Service Wires (ASW) are used for subscriber lines in exchange plant; single-pair

More information

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITH METALLIC SCREEN

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITH METALLIC SCREEN Engineering Specification Electrical Networks TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED Version: 1 Issued: March 2014 Owner: Electrical Networks Asset

More information

Single-Jacketed Tubing

Single-Jacketed Tubing Single-Jacketed Tubing COILED STICK CUT TO LENGTH UTC Single Jacketed tube Protect the tube against corrosion and pitting in a diverse changing environment and climates. The phenomenon of Chloride Stress

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 14572 Second edition 2006-11-15 Road vehicles Round, screened and unscreened 60 V and 600 V multi-core sheathed cables Test methods and requirements for basic and high-performance

More information

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P156-60

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P156-60 Solar Innova uses the latest materials to manufacture photovoltaic modules. Our modules are ideal for any application that uses the photoelectric effect as a clean energy source because of its minimal

More information

Specifications of. Single Armored Optical Fiber Cable

Specifications of. Single Armored Optical Fiber Cable SPEC. NO A15022701 Sheet no.1 of 7 Date: 15-02-27 Specifications of Single Armored Optical Fiber Cable (GYFTS) 1. General SPEC.NO A15022701 Sheet No.2 of 7 1.1 This specification covers the requirements

More information

NPS/001/007 Technical Specification for Overhead Line Conductors

NPS/001/007 Technical Specification for Overhead Line Conductors Version:- 7.0 Date of Issue:- September 2016 Page 1 of 27 NPS/001/007 Technical Specification for Overhead Line s 1. Purpose The purpose of this document is to detail the range and technical performance

More information

EXCELLENCE ON RAILS SYSTEMS FOR SAFE TRACTION POWER SUPPLY FOR UNDERGROUND/SUBURBAN RAILWAYS. Construction Automotive Industry

EXCELLENCE ON RAILS SYSTEMS FOR SAFE TRACTION POWER SUPPLY FOR UNDERGROUND/SUBURBAN RAILWAYS.  Construction Automotive Industry EXCELLENCE ON RAILS SYSTEMS FOR SAFE TRACTION POWER SUPPLY FOR UNDERGROUND/SUBURBAN RAILWAYS www.rehau.com Construction Automotive Industry EXCELLENCE ON RAILS SYSTEMS FOR SAFE TRACTION POWER SUPPLY FOR

More information

Index. P. 02 Your expertise and ours combined P. 02 Analysis of your application P. 02 Prototypes and pilot series

Index. P. 02 Your expertise and ours combined P. 02 Analysis of your application P. 02 Prototypes and pilot series Index Your partner in design P. 02 Your expertise and ours combined P. 02 Analysis of your application P. 02 Prototypes and pilot series Cost reduction P. 04 Permanent reduction of structural costs P.

More information

TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE. Kinectrics International Inc. Report No.: K RC-0001-R00.

TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE. Kinectrics International Inc. Report No.: K RC-0001-R00. To: National Cables Industry P.O Box 27472 Al Dhaid Road, Al Sajja Industrial Area Sharjah U.A.E TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE Kinectrics International Inc. Report No.: K-422341-RC-0001-R00

More information

Safe, efficient cable protection with high performance polymers

Safe, efficient cable protection with high performance polymers Safe, efficient cable protection with high performance polymers Evonik, the creative industrial group from Germany, is one of the world leaders in specialty chemicals. Its activities focus on the key megatrends

More information

3M Round, Shielded/Jacketed, Flat Cable.050" 28 AWG Stranded, Mass Terminatable, PVC/PVC 3659 Series

3M Round, Shielded/Jacketed, Flat Cable.050 28 AWG Stranded, Mass Terminatable, PVC/PVC 3659 Series M Round, Shielded/Jacketed, Flat Cable.050" 28 AWG Stranded, Mass Terminatable, PVC/PVC 659 Series Round construction permits easier routing 28 AWG wire on.050 inch pitch permits mass termination to broad

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables

More information

High Ohmic / High Voltage Metal Glaze Leaded Resistors

High Ohmic / High Voltage Metal Glaze Leaded Resistors High Ohmic / High Voltage Metal Glaze Leaded Resistors A metal glazed film is deposited on a high grade ceramic body. After a helical groove has been cut in the resistive layer, tinned electrolytic copper

More information

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-BIPV-SM-P125-36

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-BIPV-SM-P125-36 Solar Innova uses the latest materials to manufacture photovoltaic modules. Our modules are ideal for any application that uses the photoelectric effect as a clean energy source because of its minimal

More information

Flygt 3057, 50Hz. Technical Specification

Flygt 3057, 50Hz. Technical Specification Flygt 3057, 50Hz Technical Specification Table of Contents Table of Contents C-pump...2 Product description...2 Motor rating and performance curves...4 D-pump...6 Product description...6 Motor rating

More information

COPPER ALUMINUM PARTS AND SUB-ASSEMBLIES

COPPER ALUMINUM PARTS AND SUB-ASSEMBLIES COPPER Copper Wire Rod... 06 Copper Anodes... 07 Copper Cathode Sheets... 07 Copper Ingots... 07 Single Wires... 08 Welding Wires... 08 Multiwires... 09 Stranded Wires... 10 Litz Cables... 11 Flat Wires,

More information

Flygt 3057, 50Hz. Technical Specification

Flygt 3057, 50Hz. Technical Specification Flygt 3057, 50Hz Technical Specification Table of Contents Table of Contents C-pump...2 Product description...2 Motor rating and performance curves...4 D-pump...6 Product description...6 Motor rating and

More information

SPECIALISTS FOR MEDIA AND TEMPERATURE

SPECIALISTS FOR MEDIA AND TEMPERATURE SPECIALISTS FOR MEDIA AND TEMPERATURE REHAU silicon hoses SILICON The solution for extreme situations RAU-SIK is a polymer substance with excellent physical properties that are tough to beat, especially

More information

PLASTIC CONDUIT SYSTEMS 1 MADE FROM PVC 4 2 MADE FROM HALOGEN FREE RAW MATERIALS 18 3 WITH ANTIMICROBIAL PROTECTION 30 4 BURIED UNDERGROUND 42

PLASTIC CONDUIT SYSTEMS 1 MADE FROM PVC 4 2 MADE FROM HALOGEN FREE RAW MATERIALS 18 3 WITH ANTIMICROBIAL PROTECTION 30 4 BURIED UNDERGROUND 42 PRODUCT CATALOGUE PLASTIC CONDUIT SYSTEMS MADE FROM PVC 4 2 MADE FROM HALOGEN FREE RAW MATERIALS 8 3 WITH ANTIMICROBIAL PROTECTION 3 4 BURIED UNDERGROUND 42 5 FOR CONCEALED INSTALLATIONS 5 TECHNICAL INFORMATION

More information

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU INCH-POUND MIL-DTL-24643/17F 1 October 2009 SUPERSEDING MIL-DTL-24643/17E 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU This specification is approved

More information

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. ILMK 8 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma

More information

PT. KABELINDO MURNI Tbk SHIPBOARD CABLE WIRE AND CABLE MANUFACTURER. No. EMS No. OSH No. QCS 00152

PT. KABELINDO MURNI Tbk SHIPBOARD CABLE WIRE AND CABLE MANUFACTURER. No. EMS No. OSH No. QCS 00152 PT. KABELINDO MURNI Tbk WIRE AND CABLE MANUFACTURER No. QCS 00152 No. OSH 00971 No. EMS 00151 Introduction of company The Company s history was marked by the founding of PT. Kabel Indonesia (Kabelindo)

More information

ANSI/NEMA WC 71 ICEA S Nonshielded Cables Rated V for Use in the Distribution of Electric Energy

ANSI/NEMA WC 71 ICEA S Nonshielded Cables Rated V for Use in the Distribution of Electric Energy Approved as an American National Standard ANSI Approval Date: June 10, 2014 ANSI/NEMA WC 71 ICEA S-96-659-2014 Nonshielded Cables Rated 2001-5000 V for Use in the Distribution of Electric Energy Prepared

More information

UL RATED HEAT SHRINK TUBING

UL RATED HEAT SHRINK TUBING UL RATED HEAT SHRINK TUBING POLYOLEFIN SINGLE WALL TUBING POLYOLEFIN DUAL WALL TUBING www.heatshrinkdirect.net CB-HFT(600) UL/CUL NON-ADHESIVE HEAT SHRINKABLE TUBING CB-HFT(600) is UL/CUL rated halogen-free,

More information

July Metal Braids. Screening Braid and Bonding Leads

July Metal Braids. Screening Braid and Bonding Leads July 2017 Metal Braids Screening Braid and Bonding Leads Introduction IS-Cabletec who are part of the IS-Group of companies offer a range of specialist high performance screening braids, metal braids and

More information

Factors Affecting Current Ratings for Underground and Air Cables

Factors Affecting Current Ratings for Underground and Air Cables Factors Affecting Current Ratings for Underground and Air Cables S. H. Alwan, J. Jasni, M. Z. A. Ab Kadir, N. Aziz Abstract The aim of this paper is to present a parametric study to determine the major

More information

Vibration Control SCHWINGMETALL. The Original Rubber-To-Metal Bonding from ContiTech

Vibration Control SCHWINGMETALL. The Original Rubber-To-Metal Bonding from ContiTech Vibration Control SCHWINGMETALL The Original Rubber-To-Metal Bonding from ContiTech ContiTech Vibration Control Innovator and Development Partner ContiTech is an innovator and development partner for vibration-damping

More information

TEWA ELECTRONICS GROUP HIGH PRECISION NTC THERMISTORS AND TEMPERATURE SENSORS

TEWA ELECTRONICS GROUP HIGH PRECISION NTC THERMISTORS AND TEMPERATURE SENSORS TEWA TEMPERATURE SENSORS TEWA TERMICO ul. ul.litewska 14, 21-010 Łęczna, THE COMPANY PROFILE EXPERIENCE is a leading NTC Thermistor and Temperature Probe manufacturer located in Lublin, serving the European

More information

Construction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description

Construction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description January, 2009 Sarnafil TS 77-15 Polymeric membrane for roof waterproofing Construction Product Description Uses Characteristics / Advantages Approval / Standards Sarnafil TS 77-15 (thickness 1.5 mm) is

More information

OPTICAL FIBRE CABLE PERFORMANCE

OPTICAL FIBRE CABLE PERFORMANCE WWW.northeastbroadband.com TEL: 1-888-908-0386 FAX: 1-888-568-9603 Specification Sheet Page:- 1 of 2 Single Mode Optical Sterlite ITU.T - G.652 D Maximum Cabled Attenuation db/km 1310nm : 0.35 & 1550nm

More information

America s Wire Company

America s Wire Company America s Wire Company Dear Customer, We re pleased to provide you with our latest product catalog featuring many cables stocked in our warehouse located in Austin, Texas plus a backup inventory of products

More information