1 Railway Cables

2

3 Introduction Railway Cables Plant Kapfenberg-Einöd Pengg Kabel GmbH is an Austrian cable manufacturer and a member of the german Wilms group with two plants in Styria. We have two sites, one in Kapfenberg where we produce copper cables and the second in Wartberg where we are specialised on fiber optic cables and components. At the location in Kapfenberg-Einöd we have been producing railway cables for more than 40 years. In order to ensure the quality of our products and services and to improve continuously the processes, we have already in the midnineties set up a quality management system according to EN ISO 9001 which is certified by an accredited body. With our production equipment we are able to produce all usual kinds of stranding such as layer-stranding, SZ-stranding and random stranding. On this basis, we are able to produce the main types of railway and telecommunication cables. Telecommunication cables: conductor diameter 0,4 mm up to 1,8 mm symmetric local and district cables symmetric indoor cables all types of jumper wires according to national and international standards and/or customers specifications. Differential protection cables: conductor diameter 0,4 mm and 1,8 mm Cables for watersupply- as well as for power-supply companies: with pairs, triples or quads special filling materials different kinds of electrical shielding Control cables for railway applications, special cables: with plastic insulation with cores, pairs or quads spare cables in plastic version for paper-lead cables Flexibility and customer proximity are the bases for a successful development on the market. New developments and product improvements are always necessary. Apart of the permanent search for improvements of our products, our efforts for the future run towards reduction of production time, increase of flexibility and constant improvement of quality, in order to be a reliable partner for our customers. Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 3

4 Contact Persons Railway Cables Managing Director: Sales Director: Max Rothwangl Managing Director (+43) (0) (+43) (0) max.rothwangl@penggkabel.at Product Development Manager: Werner Lenger Product Development Manager - Railway Cables (+43) (0) (+43) (0) werner.lenger@penggkabel.at Uwe Löcker Key Account Manager (B, BG, BY, CH, CY, DK, E, EST, FIN, GR, H, I, IRL, L, LT, LV, N, P, RO, S) (+43) (0) (+43) (0) uwe.loecker@penggkabel.at Area representatives: PROCABLE S.A. Isabelle & Udo Guldner Area representative in France and Luxembourg 7, Z.I. Bombicht L-6947 Niederanven Luxembourg Interteam Srl Mauro Rota Area representative in Italy Via C. Battisti, 50 I Zogno (BG) Italy Cableteam FZE Stefan Leicht Area representative in UAE HQ Building A109/1 Silicon Oasis, Dubai UAE +352 (0) (0)263 procable@pt.lu URL: rota.mauro@inter-team.it URL: (0) swl501@gmail.com Key Accounts: Robert Hofreiter Key Account Manager (A, AL, BIH, HR, KOS, MK, MNE, SLO, SRB) (+43) (0) (+43) (0) robert.hofreiter@penggkabel.at Holger Quest Key Account Manager (D) (+49) (0) (+43) (0) holger.quest@penggkabel.at Gerd Pichler Key Account Manager (I, NL, D) (+43) (0) (+43) (0) gerd.pichler@penggkabel.at Sasta/Sakelliou Spyros & CO OE Spyros Sakelliou Area representative in Greece 15B, Konstantinidou Str. GR K.Patissia, Athen Greece CYNERPRO NV/SA Guy Colman Area representative in Belgium Laagstraat 65 B-9140 Temse Belgium Dr. Giorgio Cumbat Area representative in Italy Am Flecken 24 D Coburg Germany +30 (0) (0)210 sasta@otenet.gr +32 (0) guy.colman@cynerpro.be URL: (0) giorgio.cumbat@ t-online.de 4 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

5 Index Austrian Railways (ÖBB) from page 7 German Railways (DB) from page 17 French Railways (SNCF) from page 57 Swiss Railways (SBB) from page 65 Hungarian Railways (MAV) from page 69 Slovenian Railways (SZ) from page 73 Fiber Optic Cables from page 75 General Information from page 97 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 5

6 Railway Cables Note 6 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

7 Austrian Railways, ÖBB S-X2YA2YB2Y 1x4x1,53 HD page 8 S-X2YA2YB11Y 1x4x1,8 K35 page 9 S-2Y2YBY..x4x.. page 10 S-2Y2YCB2Y..x4x.. (J0...) HD page 11 Austrian Railways (ÖBB) S-2Y2YCB2Y..x.. RE (J0...) HD page 12 S-2Y2YBY..x.. RE page 13 S-2YY..x.. page 14 F-2Y2YC2Y..x2x0,8 page 15 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 7

8 Austrian Railways PE insulated, star-quad, with inductive protection S-X2YA2YB2Y 1x4x1,53 HD C42 mutual capacity 2 number of double cores 1,53 dimension of conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km S-X2YA2YB2Y 1x4x1,53 HD 2 15,0 292,8 The cable is designed for the connection of ETCS-Balisen. Conductor: Insulation: Colour code: Cable make up: Screening: Sheath: Armouring: Protective cover: Cable short mark: solid, bare copper wire 1,53 mm PE (2Y) a core : transparent b core : transparent c core : RD d core : RD cores twisted to a quad, wrapping with tape copper wire netting, tinned (9x0,10mm); aluminium shield (A) PE, black (2Y) one layer steel tape (B) HDPE, grey (2Y) special design (X) protective PE cover with high density (HD) type - LEU - SIGNAL (4 x) - PENGG KABEL - <meter> - order number Technical Details (at 20 C) Standard: Customer information Conductor diameter: 1,53 mm Loop resistance: 19,8 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 42 nf/km Attenuation: 1,8 MHz 1,0 db/100m Impedance: 1,8 MHz 120+/-20 Ω Capacitance unbalance: K pf/km e a1/2 650 pf/km conductor/conductor 2000 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Temperature range: during operation -30 to +60 C during installation -20 to +50 C 8 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

9 Austrian Railways PE insulated, star-quad, with inductive protection S-X2YA2YB11Y 1x4x1,8 K35 C45 mutual capacity 2 # 1,83² dimension of conductor number of double cores filling Austrian Railways (ÖBB) cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km S-X2YA2YB11Y 1x4x1,8 (0,35) K ,9 450,4 The cable is designed for the connection of ETCS-Balisen. Conductor: Insulation: Colour code: Cable make up: Screening: Sheath: Armouring: Protective cover: Cable short mark: strand, bare copper wire 1,83 mm² PE (2Y) a core : transparent b core : transparent c core : RD d core : RD cores twisted to a quad, wrapping with tape copper wire netting, tinned (11x0,10 mm); aluminium shield (A) PE, black (2Y) one layer steel tape (B) Polyurethan Elastollan, black (11Y) special design (X) operation termperatur till -35 C (K35) type - LEU - SIGNAL (4 x) - PENGG KABEL - <meter> - order number Technical Details (at 20 C) Standard: Customer information Conductor cross section: 1,83 mm² Loop resistance: 19,8 Ω/km Insulation resistance: 1 GΩkm Mutual capacitance (at f=800hz): 42 nf/km Attenuation: 1,8 MHz 1,0 db/100m Impedance: 1,8 MHz 120+/-20 Ω Capacitance unbalance: k pf/km e a1/2 650 pf/km conductor/conductor 2000 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Temperature range: during operation -35 to +60 C during installation -20 to +50 C Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 9

10 Austrian Railways PE insulated, star-quads, with rodent protection S-2Y2YBY..x4x.. C42 mutual capacity number of double cores 0,8 0,9 1,4 dimension of conductor filling cable elements overall shield, armouring conductor diameter 0.8 mm conductor diameter 0.9 mm conductor diameter 1.4 mm Type number of outer diameter weight outer diameter weight outer diameter weight double cores approx. mm approx. kg/km approx. mm approx. kg/km approx. mm approx. kg/km S-2Y2YBY 1x4x ,6 186,7 12,3 208,2 15,5 236,6 S-2Y2YBY 2x4x ,6 303,0 17,8 363,3 23,4 612,8 S-2Y2YBY 3x4x ,3 326,0 18,7 392,7 24,6 721,4 S-2Y2YBY 5x4x ,7 432,4 20,5 511,1 29,2 977,2 S-2Y2YBY 7x4x ,0 503,8 22,0 600,4 31,6 1181,6 S-2Y2YBY 10x4x ,2 714,4 28,0 822,7 40,5 1684,7 S-2Y2YBY 15x4x ,5 932,2 31,6 1125,0 47,1 2371,1 S-2Y2YBY 20x4x ,8 1040,1 33,1 1326,3 49,4 2843,9 S-2Y2YBY 25x4x ,4 1379,2 39,9 1706,8 60,0 3770,0 The cable is desigend for use in railway protection systems. Conductor: solid, bare copper wire 0,8 / 0,9 / 1,4 mm Insulation: PE (2Y) Colour code: beginning quad other quads a core: BK transparent b core: RD RD c core: GN GN d core: BU BU Cable make up: cores twisted to quads, quads stranded together in concentric layers, wrapping with tape Sheath: PE, black (2Y) Armouring: one or two layers steel tape (B), wrapping of tape Protective cover: PCV, grey (2Y) PENGG KABEL - type- ÖBB sign - <meter> ; SIGNAL fills the free space for gaps, less then 10 cm Technical Details (at 20 C) Standard: ÖVE- K 11 / Conductor diameter: 0,8 0,9 1,4 mm Loop resistance: 72,3 56,6 23,4 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 100% 42 nf/km 95% 40 nf/km 75% 38 nf/km Capacitance unbalance: K 1 100% pf/300m 95% pf/300m K pf/300m e a1/ pf/300m K 1 100% pf/425m ( 6 quads) pf/425m K pf/425m e a1/ pf/425m conductor/conductor 2500 V/50Hz/2min conductor/shield 2500 V/50Hz/2min Operating voltage: 250 Veff Temperature range: during operation -30 to +60 C during installation -20 to +50 C 10 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

11 Austrian Railways PE insulated, star-quad, with inductive protection S-2Y2YCB2Y x4x (J ) HD C mutual capacity 1.4 dimension of conductor number of double cores filling Austrian Railways (ÖBB) cable elements overall shield, armouring conductor diameter 0.9 mm conductor diameter 1.4. mm Type number of outer diameter weight outer diameter weight double cores approx. mm approx. kg/km approx. mm approx. kg/km S-2Y2YCB2Y 1x4x , ,3 629 S-2Y2YCB2Y 2x4x , , S-2Y2YCB2Y 3x4x , , S-2Y2YCB2Y 5x4x , , S-2Y2YCB2Y 7x4x , , S-2Y2YCB2Y 10x4x , , S-2Y2YCB2Y 15x4x , , S-2Y2YCB2Y 20x4x , , S-2Y2YCB2Y 25x4x , , The cable is desigend for use in railway protection systems. Conductor: solid, bare copper wire 0,9 / 1,4 mm Insulation: PE (2Y) Colour code: beginning quad other quads a core: BK transparent b core: RD RD c core: GN GN d core: BU BU Cable make up: cores twisted to quads, quads stranded together in concentric layers, wrapping with tape Sheath: PE, black (2Y) Screening: one layer copper wire 0,8 mm (C), wrapping of tape Armouring: two layers steel tape (B), wrapping of tape Protective cover: HDPE, grey (2Y) Cable short mark: caracteristic number of reduction factor: (J0,65) protective PE cover with high density (HD) PENGG KABEL - type- ÖBB sign - <meter> ; SIGNAL fills the free space for gaps, less then 10 cm Technical Details (at 20 C) Standard: ÖVE- K 11 / Conductor diameter: 0,9 1,4 mm Loop resistance: 56,6 23,4 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 100% 42 nf/km 95% 40 nf/km 75% 38 nf/km Capacitance unbalance: K 1 100% pf/425m ( 6 quads) pf/425m K pf/425m e a1/ pf/425m conductor/conductor V/50Hz/2min conductor/shield V/50Hz/2min Operating voltage: Veff Temperature range: during operation -30 to +60 C during installation -20 to +50 C Reduction factor: according to ÖVE-K11/ Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 11

12 Austrian Railways PE insulated, single core, with inductive protection S-2Y2YCB2Y..x.. RE (J ) HD mutual capacity 5-80 number of cores # 1,5² # 2,5² # 4,0² dimension of conductor filling cable elements overall shield, armouring cross section 1,5 mm² cross section 2,5 mm² cross section 4mm² Type number of outer diameter weight outer diameter weight outer diameter weight cores approx. mm approx. kg/km approx. mm approx. kg/km approx. mm approx. kg/km S-2Y2YCBY 5x , , ,6 770 S-2Y2YCBY 10x , , , S-2Y2YCBY 15x , , , S-2Y2YCBY 20x , , , S-2Y2YCBY 30x , , , S-2Y2YCBY 60x , , , S-2Y2YCBY 80x , , , The cable is designed for use in railway protection systems, for underground laying and drawing into conduits. The cross section of this cable type goes from 0,75 to 25 mm². Conductor: Insulation: Colour code: Cable make up: Sheath: Screening: Armouring: Protective cover: solid, bare copper wire PE (2Y) tracer core in each layer: blue other cores: transparent cores cabeld together in concentric layers, wrapping of tape PE, black (2Y) one layer copper wire 0,8 mm (C), wrapping of tape two layers steel tape (B), wrapping of tape HDPE, grey (2Y) Technical Details (at 20 C) Standard: ÖVE- K 10 / Conductor cross section: 1,5 2,5 4,0 mm² Conductor resistance: 12,1 7,28 4,56 Ω/km Insulation resistance: 5 GΩkm Mutual capacitance: nf/km conductor/conductor V/50Hz/2min conductor/shield V/50Hz/2min Operating voltage: Veff Temperature range: during operation -30 to +60 C during installation -5 to +50 C Reduction factor: according to ÖVE-K10/ Cable short mark: circular (R) single core (E) caracteristic number of redution factor: (J0,65) protective PE cover with high density (HD) PENGG KABEL - type- ÖBB sign - <meter> ; SIGNAL fills the free space for gaps, less then 10 cm 12 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

13 Austrian Railways PE insulated, star-quad, with inductive protection S-2Y2YBY..x.. RE # 0,75² mutual capacity # 1,5² # 2,5² dimension of conductor number of cores filling Austrian Railways (ÖBB) cable elements overall shield, armouring cross section 0.75 mm² cross section 1,5 mm² cross section 2.5 mm² Type number of outer diameter weight outer diameter weight outer diameter weight cores approx. mm approx. kg/km approx. mm approx. kg/km approx. mm approx. kg/km S-2Y2YBY 5x , , ,5 373 S-2Y2YBY 10x , , ,6 592 S-2Y2YBY 15x , , ,9 767 S-2Y2YBY 20x , , ,6 996 S-2Y2YBY 30x , , , S-2Y2YBY 60x , , , S-2Y2YBY 80x , , , S-2Y2YBY 100x , , , The cable is designed for use in railway protection systems, for underground laying and drawing into conduits. The cross section of this cable type goes from 0,75 to 25 mm². Conductor: Insulation: Colour code: Cable make up: Sheath: Armouring: Protective cover: solid, bare copper wire PE (2Y) tracer core in each layer: blue other cores: transparent cores cabeld together in concentric layers, wrapping of tape PE, black (2Y) one layer steel tape (B) PVC, grey (Y) Technical Details (at 20 C) Standard: ÖVE- K 10 / Conductor cross section: 0,75 1,5 2,5 mm² Conductor resistance: 24,5 12,1 7,28 Ω/km Insulation resistance: 5 GΩkm Mutual capacitance: nf/km conductor/conductor V/50Hz/2min conductor/shield V/50Hz/2min Operating voltage: Veff Temperature range: during operation -30 to +60 C during installation -5 to +50 C Cable short mark: circular (R) single core (E) PENGG KABEL - type- ÖBB sign - <meter> ; SIGNAL fills the free space for gaps, less then 10 cm Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 13

14 Austrian Railways PE insulated, single core S-2YY..x.. mutual capacity number of cores # 0,75² # 1,5² # 2,5² dimension of conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km S-2YY 10x1, ,4 287 S-2YY 10x2, ,8 418 S-2YY 19x0, ,0 289 S-2YY 19x1, ,0 468 S-2YY 19x2, ,0 730 The cable is designed for use in railway protection systems, for underground laying and drawing into conduits. The cross section of this cable type goes from 0,75 to 25 mm². Conductor: Insulation: Colour code: Cable make up: Sheath: solid, bare copper wire PE (2Y) tracer core in each layer: blue other cores: transparent cores cabeld together in concentric layers, wrapping of tape PVC, grey (Y) PENGG KABEL - type- ÖBB sign - <meter> ; SIGNAL fills the free space for gaps, less then 10 cm Technical Details (at 20 C) Standard: ÖVE- K 10 / Conductor cross section: 0,75 1,5 2,5 mm² Conductor resistance: 24,5 12,1 7,28 Ω/km Insulation resistance: 5 GΩkm Mutual capacitance: nf/km conductor/conductor V/50Hz/2min conductor/shield V/50Hz/2min Operating voltage: Veff Temperature range: during operation -30 to +60 C during installation -5 to +50 C 14 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

15 Austrian Railways PE insulated, star-quad, with copper screening F-2Y2YC2Y..x2x0,8 C55 mutual capacity dimension of conductor number of double cores filling Austrian Railways (ÖBB) cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km F-2Y2YC2Y 6x2x0, F-2Y2YC2Y 14x2x0, F-2Y2YC2Y 20x2x0, F-2Y2YC2Y 40x2x0, The cable is desigend as speaker cable for railway telecommunication. Conductor: solid, bare copper wire 0,8 mm Insulation: PE (2Y) Colour code: beginning quad other quads a core: BK transparent b core: RD RD c core: GN GN d core: BU BU Cable make up: cores twisted to quads, quads stranded together to the cable core, wrapping with tape Sheath: PE, black (2Y) Screening: one layer copper tape (C) Protective cover: PE, black (2Y) Technical Details (at 20 C) Standard: TL BB 002 / E Nt Conductor diameter: 0,8 mm Loop resistance: 72,3 Ω/km Screen resistance: 20 Ω Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 55 nf/km Capacitance unbalance: K 1 100% 800 pf/300m 95% 400 pf/300m K pf/300m e a1/2 800 pf/300m conductor/conductor 2500 V/50Hz/2min conductor/shield 2500 V/50Hz/2min order number - type - ÖBB sign - <meter> - PENGG KABEL - month and year of production - handset symbol Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 15

16 Austrian Railways Note 16 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

17 German Railways, DB A-2YOF(L)2YB2Y..x1x.. S (H115/H145) page 19 AJ-2YOF(L)2YDB2Y..x1x0,9 S (H115) page 20 AJ-2YOF(L)2YDB2Y..x1x1,4 S (H145) page 21 AJ-2YOF(L)2YDB2Y..x1x1,8 S (H145) page 22 A-2YOF(L)2YB2Y..x1x.. S (H95) page 23 AJ-2YOF(L)2YDB2Y..x1x1,4 S (H95) page 24 AJ-2YOF(L)2YDB2Y..x1x1,8 S (H95) page 25 A-2Y2YV..x1x.. S (H115/H145) page 26 A-2Y2YB2Y..x1x.. S (H115/H145) page 27 AJ-2Y2YDB2Y..x1x0,9 S (H115) page 28 German Railways (DB) AJ-2Y2YDB2Y..x1x1,4 S (H145) page 29 AJ-2Y2YDB2Y..x1x1,8 S (H145) page 30 A-2Y2YV..x1x.. S (H95) page 31 A-2Y2YB2Y..x1x.. S (H95) page 32 AJ-2Y2YDB2Y..x1x1,4 S (H95) page 33 AJ-2Y2YDB2Y..x1x1,8 S (H95) page 34 A-2Y(L)2YV..x4x.. S (H45) page 35 A-2Y(L)2YB2Y..x4x.. S (H45) page 36 AJ-2Y(L)2YDB2Y..x4x0,9 S (H45) page 37 AJ-2Y(L)2YDB2Y..x4x1,4 S (H45) page 38 A-02YSTF(L)2YV..x4x0,9 STI TNP 02 page 39 A-02YSTF(L)2YV..x4x1,4 /..x4x0,9 STI A TNP 02 page 40 A-02YSTF(L)2YB2Y 5x4x0,9 STI TNP 02 page 41 A-02YSTF(L)2Y(SR)2Y 5x4x0,9 STI TNP 02 page 42 AJ-02YSTF(L)2YDB2Y..x4x0,9 STI A TNP 02 page 43 AJ-02YSTF(L)2YDB2Y..x4x1,4 /..x4x0,9 STI A TNP 02 page 44 A-02YS(L)2YV..x4x0,7 mm² STI TNP 03 page 45 A-02YS(L)2YB2Y..x4x0,7 mm² STI TNP 03 page 46 A-02YS(L)2Y(SR)2Y..x4x0,7 mm² STI TNP 03 page 47 A-02YS2Y(ST)(ZN)2Y..x4x0,9 STI TNP 04 page 48 A-02YSF(L)2YV 2x4x1,4 / 2x4x0,9 STI TNP 06 page 49 A-02YSF(L)2Y(SR)2Y 3x4x0,9mm STI TNP 06 page 50 A-2Y(L)2YB2Y 1x4x page 51 AJ-2Y(L)2YDB2Y 1x4x1,53 page 52 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 17

18 German Railways, DB A-2YF(L)2Y..x4x0,4 STIII BD page 53 A-02YSF(L)2Y..x2x.. STIII BD page 54 AJ-02YSF(L)2YDB2Y..x2x0,8 STIII BD page Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

19 German Railways PE-insulated, single core, with rodent protection A-2YOF(L)2YB2Y..x1x.. S (H115/H145) number of cores 0,9 1,4 1,8 dimension of conductor OF filling cable elements overall shield, armouring conductor diameter 0.9 mm conductor diameter 1.4 mm conductor diameter 1.8 mm Type number of outer diameter weight outer diameter weight outer diameter weight cores approx. mm approx. kg/km approx mm approx. kg/km approx. mm approx. kg/km A-2YOF(L)2YB2Y 2x1x.. S 2 13, A-2YOF(L)2YB2Y 4x1x.. S 4 13, , ,0 300 A-2YOF(L)2YB2Y 7x1x.. S 7 14, , ,0 430 A-2YOF(L)2YB2Y 10x1x.. S 10 17, , ,0 560 A-2YOF(L)2YB2Y 14x1x.. S 14 17, , ,0 680 A-2YOF(L)2YB2Y 20x1x.. S 20 18, , ,0 890 A-2YOF(L)2YB2Y 24x1x.. S 24 20, , , A-2YOF(L)2YB2Y 30x1x.. S 30 20, , , A-2YOF(L)2YB2Y 40x1x.. S 40 21, , , A-2YOF(L)2YB2Y 50x1x.. S 50 23, , , A-2YOF(L)2YB2Y 60x1x.. S 60 25, , , A-2YOF(L)2YB2Y 80x1x.. S 80 26, , , A-2YOF(L)2YB2Y 100x1x.. S , , , A-2YOF(L)2YB2Y 120x1x.. S , , , A-2YOF(L)2YB2Y 140x1x.. S , , , A-2YOF(L)2YB2Y 160x1x.. S , , , A-2YOF(L)2YB2Y 180x1x.. S , , , A-2YOF(L)2YB2Y 200x1x.. S , , , German Railways (DB) For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 0,9 / 1,4 / 1,8 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent Cable make up: cores cabled together in concentric layers Filling: low capacity filling (OF), (longitudinal watertight) Laminated sheath: aluminium laminated PE-sheath ((L)2Y), black (transverse watertight) Armouring: 1 layer galvanized steel tape (0,3 mm) (B) for rodent protection Protective cover: PE (2Y), black Design: 2 up to 200 cores ( 0,9) 4 up to 200 cores ( 1,4 / 1,8) Technical Details (at 20 C) Standard: DB AG Conductor diameter: 0,9 1,4 1,8 mm Loop resistance: 28,9 11,9 7,2 Ω/km Insulation resistance: 1,5 1,5 1,5 GΩkm Mutual capacitance (at f=800hz): nf/km (H115) (H145) (H145) Operating voltage: V/DC Veff/100Hz Dielectric strength (cond./cond.): V/AC/1min Dielectric strength (cond./shield): V/AC/1min Temperature range: during installation -10 to +60 C during operation -40 to +60 C Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 19

20 German Railways PE-insulated, single core, with inductive protection AJ-2YOF(L)2YDB2Y..x1x0,9 S (H115) number of cores 0,9 dimension of conductor OF filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2YOF(L)2YDB2Y 10x1x0,9 S (H115) ,0 650 AJ-2YOF(L)2YDB2Y 20x1x0,9 S (H115) ,0 750 AJ-2YOF(L)2YDB2Y 30x1x0,9 S (H115) ,0 900 AJ-2YOF(L)2YDB2Y 50x1x0,9 S (H115) , AJ-2YOF(L)2YDB2Y 80x1x0,9 S (H115) , AJ-2YOF(L)2YDB2Y 120x1x0,9 S (H115) , AJ-2YOF(L)2YDB2Y 160x1x0,9 S (H115) , AJ-2YOF(L)2YDB2Y 200x1x0,9 S (H115) , AJ-2YOF(L)2YDB2Y 10x1x0,9 S (H115) ,0 750 AJ-2YOF(L)2YDB2Y 20x1x0,9 S (H115) ,0 870 AJ-2YOF(L)2YDB2Y 30x1x0,9 S (H115) , AJ-2YOF(L)2YDB2Y 50x1x0,9 S (H115) , AJ-2YOF(L)2YDB2Y 80x1x0,9 S (H115) , AJ-2YOF(L)2YDB2Y 120x1x0,9 S (H115) , AJ-2YOF(L)2YDB2Y 160x1x0,9 S (H115) , AJ-2YOF(L)2YDB2Y 200x1x0,9 S (H115) , For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 0,9 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent Cable make up: cores cabled together in concentric layers Filling: low capacity filling (OF), (longitudinal watertight) Laminated sheath:: aluminium laminated PE-sheath ((L)2Y), black (transverse watertight) Screening: 1 layer copper wires ( 0,9 / 1,2) (D) wrapping of plastic tape Armouring: 2 layer galvanized steel tape (0,5) (B) Protective cover: PE (2Y), black Design: 10 up to 200 cores ( 0,9) Technical Details (at 20 C) Standard: DB AG Conductor diameter: 0,9 mm Loop resistance: 28,9 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 115 nf/km (H115) Reduction factor: acc.to DB AG Operating voltage: 600 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Temperature range: during installation -10 to +60 C during operation -40 to +60 C Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL 20 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

21 German Railways PE-insulated, single core, with inductive protection AJ-2YOF(L)2YDB2Y..x1x1,4 S (H145) number of cores 1,4 dimension of conductor OF filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2YOF(L)2YDB2Y 10x1x1,4 S (H145) ,0 790 AJ-2YOF(L)2YDB2Y 20x1x1,4 S (H145) , AJ-2YOF(L)2YDB2Y 30x1x1,4 S (H145) , AJ-2YOF(L)2YDB2Y 50x1x1,4 S (H145) , AJ-2YOF(L)2YDB2Y 80x1x1,4 S (H145) , AJ-2YOF(L)2YDB2Y 120x1x1,4 S (H145) , AJ-2YOF(L)2YDB2Y 160x1x1,4 S (H145) , AJ-2YOF(L)2YDB2Y 200x1x1,4 S (H145) , AJ-2YOF(L)2YDB2Y 10x1x1,4 S (H145) ,0 920 AJ-2YOF(L)2YDB2Y 20x1x1,4 S (H145) , AJ-2YOF(L)2YDB2Y 30x1x1,4 S (H145) , AJ-2YOF(L)2YDB2Y 50x1x1,4 S (H145) , AJ-2YOF(L)2YDB2Y 80x1x1,4 S (H145) , AJ-2YOF(L)2YDB2Y 120x1x1,4 S (H145) , AJ-2YOF(L)2YDB2Y 160x1x1,4 S (H145) , AJ-2YOF(L)2YDB2Y 200x1x1,4 S (H145) , AJ-2YOF(L)2YDB2Y 50x1x1,4 S (H145) , AJ-2YOF(L)2YDB2Y 80x1x1,4 S (H145) , AJ-2YOF(L)2YDB2Y 120x1x1,4 S (H145) , AJ-2YOF(L)2YDB2Y 160x1x1,4 S (H145) , AJ-2YOF(L)2YDB2Y 200x1x1,4 S (H145) , German Railways (DB) For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,4 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent Cable make up: cores cabled together in concentric layers Filling: low capacity filling (OF), (longitudinal watertight) Laminated sheath:: aluminium laminated PE-sheath ((L)2Y), black (transverse watertight) Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D) wrapping of plastic tape Armouring: 2 layer galvanized steel tape (0,5 / 0,8) (B) Protective cover: PE (2Y), black Design: 10 up to 200 cores ( 1,4) Technical Details (at 20 C) Standard: DB AG Conductor diameter: 1,4 mm Loop resistance: 11,9 Ω/km Insulation resistance: 10 GΩkm mutual capacitance (at f=800hz): 145 nf/km (H145) Reduction factor: acc. to DB AG Operating voltage: 600 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Temperature range: during installation -10 to +60 C during operation -40 to +60 C Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 20

22 German Railways PE-insulated, single core, with inductive protection AJ-2YOF(L)2YDB2Y..x1x1,8 S (H145) number of cores 1,8 dimension of conductor OF filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2YOF(L)2YDB2Y 10x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 20x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 30x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 50x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 80x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 120x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 160x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 200x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 10x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 20x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 30x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 50x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 80x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 120x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 160x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 200x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 30x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 50x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 80x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 120x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 160x1x1,8 S (H145) , AJ-2YOF(L)2YDB2Y 200x1x1,8 S (H145) , For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,8 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent Cable make up: cores cabled together in concentric layers Filling: low capacity filling (OF), (longitudinal watertight) Laminated sheath:: aluminium laminated PE-sheath ((L)2Y), black (transverse watertight) Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D) wrapping of plastic tape Armouring: 2 layer galvanized steel tape (0,5 / 0,8) (B) Protective cover: PE (2Y), black Design: 10 up to 200 cores ( 0,9) Technical Details (at 20 C) Standard: DB AG Conductor diameter: 1,8 mm Loop resistance: 7,2 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz) 145 nf/km (H145) Reduction factor: acc. to DB AG Operating voltage: 60 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Temperature range: during installation -10 to +60 C during operation -40 to +60 C Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL 22 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

23 German Railways PE-insulated, single core, with rodent protection A-2YOF(L)2YB2Y..x1x.. S (H95) 4-80 number of cores 1,4 1,8 dimension of conductor OF filling cable elements overall shield, armouring conductor diameter 1.4 mm conductor diameter 1.8 mm Type number of outer diameter weight outer diameter weight cores approx mm approx. kg/km approx. mm approx. kg/km German Railways (DB) A-2YOF(L)2YB2Y 4x1x.. S (H95) 4 16, ,0 360 A-2YOF(L)2YB2Y 7x1x.. S (H95) 7 18, ,0 500 A-2YOF(L)2YB2Y 10x1x.. S (H95) 10 21, ,0 680 A-2YOF(L)2YB2Y 14x1x.. S (H95) 14 22, ,0 830 A-2YOF(L)2YB2Y 20x1x.. S (H95) 20 25, , A-2YOF(L)2YB2Y 24x1x.. S (H95) 24 28, , A-2YOF(L)2YB2Y 30x1x.. S (H95) 30 29, , A-2YOF(L)2YB2Y 40x1x.. S (H95) 40 33, , A-2YOF(L)2YB2Y 50x1x.. S (H95) 50 36, , A-2YOF(L)2YB2Y 60x1x.. S (H95) 60 39, , A-2YOF(L)2YB2Y 80x1x.. S (H95) 80 43, , For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,4 / 1,8 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent Cable make up: cores cabled together in concentric layers Filling: low capacity filling (OF), (longitudinal watertight) Laminated sheath:: aluminium laminated PE-sheath ((L)2Y), black (transverse watertight) Armouring: 1 layer galvanized steel tape (0,3 mm) (B) for rodent protection Protective cover: PE (2Y), black Design: 10 up to 20 cores ( 1,4) 10 up to 14 cores ( 1,8) Technical Details (at 20 C) Standard: DB AG Conductor diameter: 1,4 1,8 mm Loop resistance: 11,9 7,2 Ω/km Insulation resistance: GΩkm Mutual capacitance (at f=800hz) nf/km (H95) Operating voltage: V/DC Veff/100Hz Dielectric strength (cond./cond.) V/50Hz/1min Temperature range: during installation -10 to +60 C during operation -40 to +60 C Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 23

24 German Railways PE-insulated, single core, with inductive protection AJ-2YOF(L)2YDB2Y..x1x1,4 S (H95) number of cores 1,4 dimension of conductor OF filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2YOF(L)2YDB2Y 10x1x1,4 S (H95) , AJ-2YOF(L)2YDB2Y 14x1x1,4 S (H95) , AJ-2YOF(L)2YDB2Y 20x1x1,4 S (H95) , AJ-2YOF(L)2YDB2Y 30x1x1,4 S (H95) , AJ-2YOF(L)2YDB2Y 50x1x1,4 S (H95) , AJ-2YOF(L)2YDB2Y 30x1x1,4 S (H95) , AJ-2YOF(L)2YDB2Y 50x1x1,4 S (H95) , For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,4 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent Cable make up: cores cabled together in concentric layers Filling: low capacity filling (OF), (longitudinal watertight) Laminated sheath: aluminium laminated PE-sheath ((L)2Y), black (transverse watertight) Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,8) (D) wrapping of plastic tape Armouring: 2 layer galvanized steel tape (0,5 / 0,8) (B) Protective cover: PE (2Y), black Design: 10 up to 50 cores ( 1,8) Technical Details (at 20 C) Standard: DB AG Conductor diameter: 1,4 mm Loop resistance: 11,9 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 95 nf/km (H95) Reduction factor: acc. to DB AG Operating voltage: 600 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Temperature range: during installation -10 to +60 C during operation -40 to +60 C Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL 24 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

25 German Railways PE-insulated, single core, with inductive protection AJ-2YOF(L)2YDB2Y..x1x1,8 S (H95) number of cores 1,8 dimension of conductor OF filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2YOF(L)2YDB2Y 10x1x1,8 S (H95) , AJ-2YOF(L)2YDB2Y 14x1x1,8 S (H95) , AJ-2YOF(L)2YDB2Y 20x1x1,8 S (H95) , AJ-2YOF(L)2YDB2Y 30x1x1,8 S (H95) , AJ-2YOF(L)2YDB2Y 50x1x1,8 S (H95) , AJ-2YOF(L)2YDB2Y 30x1x1,8 S (H95) , AJ-2YOF(L)2YDB2Y 50x1x1,8 S (H95) , German Railways (DB) For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,8 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent Cable make up: cores cabled together in concentric layers Filling: low capacity filling (OF), (longitudinal watertight) Laminated sheath:: aluminium laminated PE-sheath ((L)2Y), black (transverse watertight) Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,8) (D) wrapping of plastic tape Armouring: 2 layer galvanized steel tape (0,5 / 0,8) (B) Protective cover: PE (2Y), black Design: 10 up to 50 cores ( 1,8) Technical Details (at 20 C) Standard: DB AG Conductor diameter: 1,8 mm Loop resistance: 7,2 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 95 nf/km (H95) Reduction factor: acc. to DB AG Operating voltage: 600 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Temperature range: during installation -10 to +60 C during operation -40 to +60 C Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 25

26 German Railways PE-insulated, core stranded, with reinforced sheath A-2Y2YV..x1x.. S (H115/H145) number of cores 0,9 1,4 1,8 dimension of conductor filling cable elements overall shield, armouring conductor diameter 0.9 mm conductor diameter 1.4 mm conductor diameter 1.8 mm Type number of outer diameter weight outer diameter weight outer diameter weight cores approx. mm approx. kg/km approx mm approx. kg/km approx. mm approx. kg/km A-2Y2YV 2x1x.. S 2 9, A-2Y2YV 4x1x.. S 4 9, , ,0 200 A-2Y2YV 7x1x.. S 7 11, , ,0 300 A-2Y2YV 10x1x.. S 10 12, , ,0 420 A-2Y2YV 14x1x.. S 14 13, , ,0 560 A-2Y2YV 20x1x.. S 20 14, , ,0 760 A-2Y2YV 24x1x.. S 24 15, , ,0 900 A-2Y2YV 30x1x.. S 30 16, , , A-2Y2YV 40x1x.. S 40 17, , , A-2Y2YV 50x1x.. S 50 19, , , A-2Y2YV 60x1x.. S 60 20, , , A-2Y2YV 80x1x.. S 80 22, , , A-2Y2YV 100x1x.. S , , , A-2Y2YV 120x1x.. S , , , A-2Y2YV 140x1x.. S , , , A-2Y2YV 160x1x.. S , , , A-2Y2YV 180x1x.. S , , , A-2Y2YV 200x1x.. S , , , For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 0,9 / 1,4 / 1,8 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent monitoring core: grey Cable make up: cores cabled together in concentric layers 2 perforated cores ( 0,5 mm; in cables with 14 cores) wrapping of plastic tape Sheath: PE, reinforced (2YV), black Design: 2 up to 200 cores ( 0,9) 4 up to 200 cores ( 1,4 / 1,8) Laying Usable for underground laying and drawing into conduits. Technical Details (at 20 C) Standard: DB AG Conductor diameter: 0,9 1,4 1,8 mm Conductor resistance: 28,9 11,9 7,2 Ω/km Insulation resistance: GΩkm Mutual capacitance (at f=800hz): nf/km (H115) (H145) (H145) Operating voltage: V/DC Veff/100Hz Dielectric strength (cond./cond.) V/AC/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Mutual capacitance (at f=800hz): N/A nf/km Dielectric strength (cond./cond.) 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL 26 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

27 German Railways PE-insulated, single core, with rodent protection A-2Y2YB2Y..x1x.. S (H115/H145) number of cores 0,9 1,4 1,8 dimension of conductor filling cable elements overall shield, armouring conductor diameter 0.9 mm conductor diameter 1.4 mm conductor diameter 1.8 mm Type number of outer diameter weight outer diameter weight outer diameter weight cores approx. mm approx. kg/km approx mm approx. kg/km approx. mm approx. kg/km German Railways (DB) A-2Y2YB2Y 2x1x.. S 2 12, A-2Y2YB2Y 4x1x.. S 4 13, , ,5 290 A-2Y2YB2Y 7x1x.. S 7 14, , ,0 410 A-2Y2YB2Y 10x1x.. S 10 15, , ,0 540 A-2Y2YB2Y 14x1x.. S 14 16, , ,0 720 A-2Y2YB2Y 20x1x.. S 20 17, , ,0 950 A-2Y2YB2Y 24x1x.. S 24 19, , , A-2Y2YB2Y 30x1x.. S 30 19, , , A-2Y2YB2Y 40x1x.. S 40 20, , , A-2Y2YB2Y 50x1x.. S 50 22, , A-2Y2YB2Y 60x1x.. S 60 23, , A-2Y2YB2Y 80x1x.. S 80 25, A-2Y2YB2Y 100x1x.. S , A-2Y2YB2Y 120x1x.. S , A-2Y2YB2Y 140x1x.. S , For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 0,9 / 1,4 / 1,8 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent monitoring core: grey Cable make up: cores cabled together in concentric layers 2 perforated cores ( 0,5 mm; in cables with 14 cores) wrapping of plastic tape Sheath: PE (2Y), black Armouring: 1 layer galvanized steel tape (0,3 mm) (B) for rodent protection Protective cover: PE (2Y), black Design: 2 up to 140 cores ( 0,9) 4 up to 60 cores ( 1,4) 4 up to 40 cores ( 1,8) Technical Details (at 20 C) Standard: DB AG Conductor diameter: 0,9 1,4 1,8 mm Conductor resistance: 28,9 11,9 7,2 Ω/km Insulation resistance: GΩkm Mutual capacitance (at f=800hz): nf/km (H115) (H145) (H145) Operating voltage: V/DC Veff/100Hz Dielectric strength (cond./cond.): V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Mutual capacitance (at f=800hz): N/A nf/km Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 27

28 German Railways PE-insulated, single core, with inductive protection AJ-2Y2YDB2Y..x1x0,9 S (H115) number of cores 0,9 dimension of conductor filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2Y2YDB2Y 10x1x0,9 S (H115) ,0 620 AJ-2Y2YDB2Y 20x1x0,9 S (H115) ,0 780 AJ-2Y2YDB2Y 30x1x0,9 S (H115) ,0 940 AJ-2Y2YDB2Y 50x1x0,9 S (H115) , AJ-2Y2YDB2Y 80x1x0,9 S (H115) , AJ-2Y2YDB2Y 120x1x0,9 S (H115) , AJ-2Y2YDB2Y 160x1x0,9 S (H115) , AJ-2Y2YDB2Y 200x1x0,9 S (H115) , AJ-2Y2YDB2Y 10x1x0,9 S (H115) ,0 690 AJ-2Y2YDB2Y 20x1x0,9 S (H115) ,0 880 AJ-2Y2YDB2Y 30x1x0,9 S (H115) , AJ-2Y2YDB2Y 50x1x0,9 S (H115) , AJ-2Y2YDB2Y 80x1x0,9 S (H115) , AJ-2Y2YDB2Y 120x1x0,9 S (H115) , AJ-2Y2YDB2Y 160x1x0,9 S (H115) , AJ-2Y2YDB2Y 200x1x0,9 S (H115) , For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 0,9 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent monitoring core: grey Cable make up: cores cabled together in concentric layers 2 perforated cores ( 0,5 mm; in cables with 14 cores) wrapping of plastic tape Sheath: PE (2Y), black Screening: 1 layer copper wires ( 0,9 / 1,2) (D) wrapping of plastic tape Armouring: 2 layers galvanized steel tape (0,5) (B) Protective cover: PE (2Y), black Design: 10 up to 200 cores ( 0,9) Laying Usable for underground laying and drawing into conduits. Technical Details (at 20 C) Standard: DB AG Conductor diameter: 0,9 mm Conductor resistance: 28,9 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 115 nf/km (H115) Reduction factor: acc. DB AG Operating voltage: 600 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Mutual capacitance (at f=800hz): N/A nf/km Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL 28 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

29 German Railways PE-insulated, single core, with inductive protection AJ-2Y2YDB2Y..x1x1,4 S (H145) number of cores 1,4 dimension of conductor filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2Y2YDB2Y 10x1x1,4 S (H145) ,0 840 AJ-2Y2YDB2Y 20x1x1,4 S (H145) , AJ-2Y2YDB2Y 30x1x1,4 S (H145) , AJ-2Y2YDB2Y 50x1x1,4 S (H145) , AJ-2Y2YDB2Y 80x1x1,4 S (H145) , AJ-2Y2YDB2Y 120x1x1,4 S (H145) , AJ-2Y2YDB2Y 160x1x1,4 S (H145) , AJ-2Y2YDB2Y 200x1x1,4 S (H145) , AJ-2Y2YDB2Y 10x1x1,4 S (H145) ,0 950 AJ-2Y2YDB2Y 20x1x1,4 S (H145) , AJ-2Y2YDB2Y 30x1x1,4 S (H145) , AJ-2Y2YDB2Y 50x1x1,4 S (H145) , AJ-2Y2YDB2Y 80x1x1,4 S (H145) , AJ-2Y2YDB2Y 120x1x1,4 S (H145) , AJ-2Y2YDB2Y 160x1x1,4 S (H145) , AJ-2Y2YDB2Y 200x1x1,4 S (H145) , AJ-2Y2YDB2Y 50x1x1,4 S (H145) , AJ-2Y2YDB2Y 80x1x1,4 S (H145) , AJ-2Y2YDB2Y 120x1x1,4 S (H145) , AJ-2Y2YDB2Y 160x1x1,4 S (H145) , AJ-2Y2YDB2Y 200x1x1,4 S (H145) , German Railways (DB) For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,4 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent monitoring core: grey Cable make up: cores cabled together in concentric layers 2 perforated cores ( 0,5 mm; in cables with 14 cores) wrapping of plastic tape Sheath: PE (2Y), black Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D) wrapping of plastic tape Armouring: 2 layers galvanized steel tape (0,5 / 0,8) (B) Protective cover: PE (2Y), black Design: 10 up to 200 cores ( 1,4) Laying Usable for underground laying and drawing into conduits. Technical Details (at 20 C) Standard: DB AG Conductor diameter: 1,4 mm Conductor resistance: 11,9 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 145 nf/km (H145) Reduction factor: acc. DB AG Operating voltage: 600 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Mutual capacitance (at f=800hz): N/A nf/km Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 29

30 German Railways PE-insulated, single core, with inductive protection AJ-2Y2YDB2Y..x1x1,8 S (H145) number of cores 1,8 dimension of conductor filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2Y2YDB2Y 10x1x1,8 S (H145) ,0 950 AJ-2Y2YDB2Y 20x1x1,8 S (H145) , AJ-2Y2YDB2Y 30x1x1,8 S (H145) , AJ-2Y2YDB2Y 50x1x1,8 S (H145) , AJ-2Y2YDB2Y 80x1x1,8 S (H145) , AJ-2Y2YDB2Y 120x1x1,8 S (H145) , AJ-2Y2YDB2Y 160x1x1,8 S (H145) , AJ-2Y2YDB2Y 200x1x1,8 S (H145) , AJ-2Y2YDB2Y 10x1x1,8 S (H145) , AJ-2Y2YDB2Y 20x1x1,8 S (H145) , AJ-2Y2YDB2Y 30x1x1,8 S (H145) , AJ-2Y2YDB2Y 50x1x1,8 S (H145) , AJ-2Y2YDB2Y 80x1x1,8 S (H145) , AJ-2Y2YDB2Y 120x1x1,8 S (H145) , AJ-2Y2YDB2Y 160x1x1,8 S (H145) , AJ-2Y2YDB2Y 200x1x1,8 S (H145) , AJ-2Y2YDB2Y 30x1x1,8 S (H145) , AJ-2Y2YDB2Y 50x1x1,8 S (H145) , AJ-2Y2YDB2Y 80x1x1,8 S (H145) , AJ-2Y2YDB2Y 120x1x1,8 S (H145) , AJ-2Y2YDB2Y 160x1x1,8 S (H145) , AJ-2Y2YDB2Y 200x1x1,8 S (H145) , For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,8 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent monitoring core: grey Cable make up: cores cabled together in concentric layers 2 perforated cores ( 0,5 mm; in cables with 14 cores) wrapping of plastic tape Sheath: PE (2Y), black Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D) wrapping of plastic tape Armouring: 2 layers galvanized steel tape (0,5 / 0,8) (B) Protective cover: PE (2Y), black Design: 10 up to 200 cores ( 0,9) Laying Usable for underground laying and drawing into conduits. Technical Details (at 20 C) Standard: DB AG Conductor diameter: 1,8 mm Conductor resistance: 7,2 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 145 nf/km (H145) Reduction factor: acc. DB AG Operating voltage: 600 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Mutual capacitance (at f=800hz): N/A nf/km Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL 30 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

31 German Railways PE-insulated, single core, with reinforced sheath A-2Y2YV..x1x.. S (H95) number of cores 1,4 1,8 dimension of conductor filling cable elements overall shield, armouring conductor diameter 1.4 mm conductor diameter 1.8 mm Type number of outer diameter weight outer diameter weight cores approx mm approx. kg/km approx. mm approx. kg/km German Railways (DB) A-2Y2YV 10x1x.. S (H95) 10 16, ,0 470 A-2Y2YV 14x1x.. S (H95) 14 18, ,0 640 A-2Y2YV 20x1x.. S (H95) 20 20, ,0 860 A-2Y2YV 30x1x.. S (H95) 30 24, , A-2Y2YV 50x1x.. S (H95) 50 29, , For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,4 / 1,8 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent monitoring core: grey Cable make up: cores cabled together in concentric layers 2 perforated cores ( 0,5 mm; in cables with 14 cores) wrapping of plastic tape Sheath: PE, reinforced (2YV), black Design: 10 up to 50 cores ( 1,4 / 1,8) Laying Usable for underground laying and drawing into conduits. Technical Details (at 20 C) Standard: DB AG Conductor diameter: 1,4 1,8 mm Conductor resistance: 11,9 7,2 Ω/km Insulation resistance: GΩkm Mutual capacitance (at f=800hz): nf/km (H95) Operating voltage: V/DC Veff/100Hz Dielectric strength (cond./cond.): V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Mutual capacitance (at f=800hz): N/A nf/km Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 31

32 German Railways PE-insulated, single core, with rodent protection A-2Y2YB2Y..x1x.. S (H95) number of cores 1,4 1,8 dimension of conductor filling cable elements overall shield, armouring conductor diameter 1.4 mm conductor diameter 1.8 mm Type number of outer diameter weight outer diameter weight cores approx mm approx. kg/km approx. mm approx. kg/km A-2Y2YB2Y 10x1x.. S (H95) 10 18, ,0 650 A-2Y2YB2Y 14x1x.. S (H95) 14 20, ,0 820 A-2Y2YB2Y 20x1x.. S (H95) 20 22, For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: Insulation: Colour code: Cable make up: Sheath: Armouring: Protective cover: solid, bare copper wire 1,4 / 1,8 mm PE (2Y) tracer core in each layer: blue other cores: transparent monitoring core: grey cores cabled together in concentric layers 2 perforated cores ( 0,5 mm; in cables with 14 cores) wrapping of plastic tape PE (2Y), black 1 layer galvanized steel tape (0,3 mm) (B) for rodent protection PE (2Y), black Design: 10 up to 20 cores ( 1,4) 10 up to 14 cores ( 1,8) Technical Details (at 20 C) Standard: DB AG Conductor diameter: 1,4 1,8 mm Conductor resistance: Ω/km Insulation resistance: GΩkm Mutual capacitance (at f=800hz): nf/km (H95) Operating voltage: V/DC Veff/100Hz Dielectric strength (cond./cond.): V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Mutual capacitance (at f=800hz:) N/A nf/km Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL 32 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

33 German Railways PE-insulated, single core, with inductive protection AJ-2Y2YDB2Y..x1x1,4 S (H95) number of cores 1,4 dimension of conductor filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2Y2YDB2Y 10x1x1,4 S (H95) ,0 990 AJ-2Y2YDB2Y 14x1x1,4 S (H95) , AJ-2Y2YDB2Y 20x1x1,4 S (H95) , AJ-2Y2YDB2Y 30x1x1,4 S (H95) , AJ-2Y2YDB2Y 50x1x1,4 S (H95) , AJ-2Y2YDB2Y 30x1x1,4 S (H95) , AJ-2Y2YDB2Y 50x1x1,4 S (H95) , German Railways (DB) For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,4 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent monitoring core: grey Cable make up: cores cabled together in concentric layers 2 perforated cores ( 0,5 mm; in cables with 14 cores) wrapping of plastic tape Sheath: PE (2Y), black Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D) wrapping of plastic tape Armouring: 2 layers galvanized steel tape (0,5 / 0,8) (B) Protective cover: PE (2Y), black Design: 10 up to 50 cores ( 1,4) Laying Usable for underground laying and drawing into conduits. Technical Details (at 20 C) Standard: DB AG Conductor diameter: 1,4 mm Conductor resistance: 11,9 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 95 nf/km (H95) Reduction factor: acc. DB AG Operating voltage: 600 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Mutual capacitance (at f=800hz): N/A nf/km Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 33

34 German Railways PE-insulated, single core, with inductive protection AJ-2Y2YDB2Y..x1x1,8 S (H95) number of cores 1,8 dimension of conductor filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2Y2YDB2Y 10x1x1,8 S (H95) , AJ-2Y2YDB2Y 14x1x1,8 S (H95) , AJ-2Y2YDB2Y 20x1x1,8 S (H95) , AJ-2Y2YDB2Y 30x1x1,8 S (H95) , AJ-2Y2YDB2Y 50x1x1,8 S (H95) , AJ-2Y2YDB2Y 30x1x1,8 S (H95) , AJ-2Y2YDB2Y 50x1x1,8 S (H95) , For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of 420 Veff. Conductor: solid, bare copper wire 1,8 mm Insulation: PE (2Y) Colour code: tracer core in each layer: blue other cores: transparent monitoring core: grey Cable make up: cores cabled together in concentric layers 2 perforated cores ( 0,5 mm; in cables with 14 cores) wrapping of plastic tape Sheath: PE (2Y), black Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,8) (D) wrapping of plastic tape Armouring: 2 layers galvanized steel tape (0,5 / 0,8) (B) Protective cover: PE (2Y), black Design: 10 up to 50 cores ( 1,8) Laying Usable for underground laying and drawing into conduits. Technical Details (at 20 C) Standard: DB AG Conductor diameter: 1,8 mm Conductor resistance: 7,2 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 95 nf/km (H95) Reduction factor: acc. DB AG Operating voltage: 600 V/DC 420 Veff/100Hz conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Mutual capacitance (at f=800hz): N/A nf/km Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL 34 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

35 German Railways PE-insulated, star-quads, with reinforced sheath A-2Y(L)2YV..x4x.. S (H45) 2-80 number of double cores 0,9 1,4 dimension of conductor filling cable elements overall shield, armouring conductor diameter 0.9 mm conductor diameter 1.4 mm Type number of outer diameter weight outer diameter weight double cores approx mm approx. kg/km approx. mm approx. kg/km German Railways (DB) A-2Y(L)2YV 1x4x.. S 2 10, ,0 170 A-2Y(L)2YV 3x4x.. S 6 15, ,0 410 A-2Y(L)2YV 5x4x.. S 10 17, ,0 620 A-2Y(L)2YV 7x4x.. S 14 19, ,0 800 A-2Y(L)2YV 10x4x.. S 20 22, , A-2Y(L)2YV 14x4x.. S 28 25, , A-2Y(L)2YV 20x4x.. S 40 28, , A-2Y(L)2YV 30x4x.. S 60 34, , A-2Y(L)2YV 40x4x.. S 80 38, , For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of alternating currents up to 90 khz in systems, which require a high symmetry against each other and outside disturbers as well as in relation to the earth potential. Conductor: solid, bare copper wire 0,9 / 1,4 mm Insulation: PE (2Y) Identification: basic colour grey, ring marking according to DB AG , monitoring cores: grey Cable make up: cores twisted to quads, quads cabled together in concentric layers, the tracer quad in each layer is marked with an open blue helix. 2 perforated cores ( 0,5 mm; in cables with 7 quads) wrapping of plastic tape tinned copper wire ( 0,4 mm) Sheath: aluminium laminated PE-sheath, reinforced ((L)2YV), black Design: 1 up to 40 quads ( 0,9 / 1,4) Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Technical Details (at 20 C) Standard: DB AG Conductor diameter: 0,9 1,4 mm Loop resistance: 56,6 23,4 Ω/km Insulation resistance: GΩkm Mutual capacitance (at f=800hz): nf/km (H45) Capacitance unbalance:k 1 100% pf/500m (at f=800hz) 50% 150 pf/500m Capacitance unbalance:k % pf/500m (at f=800hz) 50% 150 pf/500m Capacitance unbalance:e 1/2 100% pf/500m (at f=800hz) e a1/2 100% pf/500m Image attenuation constant: 100% 3,3 2,6 db/km (at f=90khz) FEXT: 100% db/km (at f=90khz) 80% 62 db/km conductor/conductor V/50Hz/1min conductor/shield V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 35

36 German Railways PE-insulated, star-quads, with rodent protection A-2Y(L)2YB2Y..x4x.. S (H45) 2-28 number of double cores 0,9 1,4 dimension of conductor filling cable elements overall shield, armouring conductor diameter 0.9 mm conductor diameter 1.4 mm Type number of outer diameter weight outer diameter weight double cores approx mm approx. kg/km approx. mm approx. kg/km A-2Y(L)2YB2Y 1x4x.. S 2 12, ,0 260 A-2Y(L)2YB2Y 3x4x.. S 6 17, ,0 570 A-2Y(L)2YB2Y 5x4x.. S 10 19, ,0 820 A-2Y(L)2YB2Y 7x4x.. S 14 21, , A-2Y(L)2YB2Y 10x4x.. S 20 24, A-2Y(L)2YB2Y 14x4x.. S 28 27, For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of alternating currents up to 90 khz in systems, which require a high symmetry against each other and outside disturbers as well as in relation to the earth potential. Conductor: solid, bare copper wire 0,9 / 1,4 mm Insulation: PE (2Y) Identification: basic colour grey, ring marking according to DB AG , monitoring cores: grey Cable make up: cores twisted to quads, quads cabled together in concentric layers, the tracer quad in each layer is marked with an open blue helix. 2 perforated cores ( 0,5 mm; in cables with 7 quads) wrapping of plastic tape tinned copper wire ( 0,4 mm) Sheath: aluminium laminated PE-sheath, ((L)2Y), black Armouring: 1 layer galvanized steel tape (0,3 mm) (B) for rodent protection Protective cover: PE (2Y), black Design: 1 up to 14 quads ( 0,9) 1 up to 7 quads ( 1,4) Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Technical Details (at 20 C) Standard: DB AG Conductor diameter: 0,9 1,4 mm Loop resistance: 56,6 23,4 Ω/km Insulation resistance: GΩkm Mutual capacitance (at f=800hz): nf/km (H45) Capacitance unbalance: k 1 100% pf/500m (at f=800hz) 50% 150 pf/500m Capacitance unbalance: k % pf/500m (at f=800hz) 50% 150 pf/500m Capacitance unbalance: e 1/2 100% pf/500m (at f=800hz) e a1/2 100% pf/500m Image attenuation constant: 100% db/km (at f=90khz) FEXT: 100% db/km (at f=90khz) 80% 62 db/km conductor/conductor V/50Hz/1min conductor/shield V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C 36 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

37 German Railways PE-insulated, star quads, with inductive protection AJ-2Y(L)2YDB2Y..x4x0,9 S (H45) 6-80 number of double cores 0,9 dimension of conductor filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight double cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2Y(L)2YDB2Y 3x4x0,9 S (H45) ,0 800 AJ-2Y(L)2YDB2Y 5x4x0,9 S (H45) , AJ-2Y(L)2YDB2Y 10x4x0,9 S (H45) , AJ-2Y(L)2YDB2Y 20x4x0,9 S (H45) , AJ-2Y(L)2YDB2Y 30x4x0,9 S (H45) , AJ-2Y(L)2YDB2Y 40x4x0,9 S (H45) , AJ-2Y(L)2YDB2Y 10x4x0,9 S (H45) , AJ-2Y(L)2YDB2Y 20x4x0,9 S (H45) , AJ-2Y(L)2YDB2Y 30x4x0,9 S (H45) , AJ-2Y(L)2YDB2Y 40x4x0,9 S (H45) , German Railways (DB) for general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of alternating currents up to 90 khz in systems, which require a high symmetry against each other and outside disturbers as well as in relation to the earth potential. Conductor: solid, bare copper wire 0,9 mm Insulation: PE (2Y) Identification: basic colour grey, ring marking according to DB AG , monitoring cores: grey Cable make up: cores twisted to quads, quads cabled together in concentric layers, the tracer quad in each layer is marked with an open blue helix. 2 perforated cores ( 0,5 mm; in cables with 7 quads) wrapping of plastic tape tinned copper wire ( 0,4 mm) Sheath: aluminium laminated PE-sheath, ((L)2Y), black Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D) wrapping of plastic tape Armouring: 2 layers galvanized steel tape (0,5/0,8) (B) Protective cover: PE (2Y), black Design: 6 up to 80 double cores ( 0,9) Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Technical Details (at 20 C) Standard: DB AG Conductor diameter: 0,9 mm Loop resistance: 56,6 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 45 nf/km (H45) Capacitance unbalance: k 1 100% 650 pf/500m (at f=800hz) 50% 150 pf/500m Capacitance unbalance: k % 500 pf/500m (at f=800hz) 50% 150 pf/500m Capacitance unbalance: e 1/2 100% 1300 pf/500m (at f=800hz) e a1/2 100% 1300 pf/500m Image attenuation constant: 100% 3.3 db/km (at f=90khz) FEXT: 100% 58 db/km (at f=90khz) 80% 62 db/km conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 37

38 German Railways PE-insulated, star quads, with inductive protection AJ-2Y(L)2YDB2Y..x4x1,4 S (H45) 6-80 number of double cores 1,4 dimension of conductor filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight double cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2Y(L)2YDB2Y 3x4x1,4 S (H45) , AJ-2Y(L)2YDB2Y 5x4x1,4 S (H45) , AJ-2Y(L)2YDB2Y 10x4x1,4 S (H45) , AJ-2Y(L)2YDB2Y 20x4x1,4 S (H45) , AJ-2Y(L)2YDB2Y 30x4x1,4 S (H45) , AJ-2Y(L)2YDB2Y 40x4x1,4 S (H45) , AJ-2Y(L)2YDB2Y 5x4x1,4 S (H45) , AJ-2Y(L)2YDB2Y 10x4x1,4 S (H45) , AJ-2Y(L)2YDB2Y 20x4x1,4 S (H45) , AJ-2Y(L)2YDB2Y 30x4x1,4 S (H45) , AJ-2Y(L)2YDB2Y 40x4x1,4 S (H45) , For general use in protection systems (unless the application of special cable of safety engineering, e.g. Indusi connection cables, is specified), preferably for transmission of alternating currents up to 90 khz in systems, which require a high symmetry against each other and outside disturbers as well as in relation to the earth potential. Conductor: solid, bare copper wire 1,4 mm Insulation: PE (2Y) Identification: basic colour grey, ring marking according to DB AG , monitoring cores: grey Cable make up: cores twisted to quads, quads cabled together in concentric layers, the tracer quad in each layer is marked with an open blue helix. 2 perforated cores ( 0,5 mm; in cables with 7 quads) wrapping of plastic tape tinned copper wire ( 0,4 mm) Sheath: aluminium laminated PE-sheath ((L)2Y), black. Screening: 1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D) wrapping of plastic tape Armouring: 2 layers galvanized steel tape (0,5 / 0,8) (B) Protective cover: PE (2Y), black Design: 6 up to 80 double cores ( 0,9) Laying Usable for underground laying and drawing into conduits. 1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL 2nd line (if cable >20mm): SIGNAL Technical Details (at 20 C) Standard: DB AG Conductor diameter: 1,4 mm Loop resistance: 23,4 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance (at f=800hz): 45 nf/km (H45) Capacitance unbalance: k 1 100% 650 pf/500m (at f=800hz) Capacitance unbalance: k % 500 pf/500m (at f=800hz) Capacitance unbalance: e 1/2 100% 1300 pf/500m (at f=800hz) e a1/2 100% 1300 pf/500m Image attenuation constant: 100% 2,6 db/km (at f=90khz) FEXT 100% 33 db/km (at f=90khz) conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. Dielectric strength (cond./cond.): 2500 V/50Hz/1min Temperature range: during installation -10 up to +60 C for stationary conditions -40 up to +60 C 38 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

39 German Railways PE-foam skin insulated, star quads, reinforced sheath A-02YSTF(L)2YV..x4x0,9 STI TNP 02 C34 mutual capacitance number of double cores 0,9 dimension of copper conductor TF filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-02YSTF(L)2YV 5x4x0,9 STI TNP ,0 300 A-02YSTF(L)2YV 10x4x0,9 STI TNP ,0 570 A-02YSTF(L)2YV 16x4x0,9 STI TNP ,0 790 A-02YSTF(L)2YV 19x4x0,9 STI TNP ,0 940 A-02YSTF(L)2YV 24x4x0,9 STI TNP , A-02YSTF(L)2YV 30x4x0,9 STI TNP , German Railways (DB) The cable is designed for use as railway signalling cable for long distances. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol solid, bare copper wire 0,9 mm PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to star-quads, quads stranded together in concentric layers, 2 perforated cores ( 0,5 mm), wrapping with swellable tape (TF) aluminium laminated PE-sheath, reinforced black ((L)2YV) Technical Details (at 20 C) Standard: Arcor TNP 02 Conductor diameter: 0,9 mm Loop resistance: 56,6 Ω/km Resistance difference: 0,30 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance: 34 nf/km Capacitance unbalance: k pf/km k pf/km e a1/ pf/km Attenuation: 800 Hz 0,6 db/km Operating voltage: 250 V eff Near-end crosstalk: 45 db/abs. Far-end crosstalk: 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 39

40 German Railways PE-foam skin insulated,star quads,with reinforced sheath A-02YSTF(L)2YV..x4x1,4 /..x4x0,9 STI A TNP 02 C36 C34 mutual capacitance number of double cores dimension of conductor TF filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-02YSTF(L)2YV 1x4x1,4 / 7x4x0,9 STI A TNP ,0 510 A-02YSTF(L)2YV 2x4x1,4 / 11x4x0,9 STI A TNP ,0 820 A-02YSTF(L)2YV 3x4x1,4 / 12x4x0,9 STI A TNP ,0 940 A-02YSTF(L)2YV 4x4x1,4 / 13x4x0,9 STI A TNP , A-02YSTF(L)2YV 5x4x1,4 / 16x4x0,9 STI A TNP , A-02YSTF(L)2YV 3x4x1,4 / 30x4x0,9 STI A TNP , The cable is designed for use as railway signalling cable for long distances. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol solid, bare copper wire 0,9 / 1,4 mm PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to star-quads, quads stranded together in concentric layers, 2 perforated cores ( 0,5 mm), wrapping with swellable tape (TF) aluminium laminated PE-sheath, reinforced, black ((L)2YV) Technical Details (at 20 C) Standard: Arcor TNP 02 Conductor diameter: 0,9 1,4 mm Loop resistance: 56,6 23,4 Ω/km Resistance difference: 0,30 0,20 Ω/km Insulation resistance: L>200m GΩkm 100m L 200m GΩkm L<100m GΩkm Mutual capacitance: nf/km Capacitance unbalance: k pf/km k pf/km e a1/ pf/km Attenuation: 800 Hz 0,6 0,4 db/km Operating voltage: V eff Near-end crosstalk: db abs. Far-end crosstalk: db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min 40 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

41 German Railways PE-foam skin insulated, star quads, with rodent protection A-02YSTF(L)2YB2Y 5x4x0,9 STI TNP 02 C34 mutual capacitance 10 number of double cores 0,9 dimension of copper conductor TF filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-02YSTF(L)2YB2Y 5x4x0,9 STI TNP ,2 521 German Railways (DB) The cable is designed for use as railway signalling cable for long distances. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: Armouring: Protective cover: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol solid, bare copper wire 0,9 mm PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to star-quads, quads stranded together in concentric layers, 2 perforated cores ( 0,5 mm), wrapping with swellable tape (TF) aluminium laminated PE-sheath, black ((L)2Y) one layer galvanized steel tape (B) PE, black (2Y) Technical Details (at 20 C) Standard: Arcor TNP 02 Conductor diameter: 0,9 mm Loop resistance: 56,6 Ω/km Resistance difference: 0,30 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance: 34 nf/km Capacitance unbalance: k pf/km k pf/km e a1/ pf/km Attenuation: 800 Hz 0,6 db/km Operating voltage: 250 V eff Near-end crosstalk: 45 db/abs. Far-end crosstalk: 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 41

42 German Railways PE-foam skin insulated, star quads, with rodent protection A-02YSTF(L)2Y(SR)2Y 5x4x0,9 STI TNP 02 C34 mutual capacitance 10 number of double cores 0.9 dimension of conductor F filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-02YSTF(L)2Y(SR)2Y 5x4x0,9 STI TNP ,2 495,1 The cable is designed for use as railway signalling cable for long distances. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: Armouring: Protective cover: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol solid, bare copper wire 0,9 mm PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to star-quads, quads stranded together in concentric layers, 2 perforated cores ( 0,5 mm), wrapping with swellable tape aluminium laminated PE-sheath, black ((L)2Y) one layer of corrugated steel tape ((SR)), wrapping of tape PE, black (2Y) Technical Details (at 20 C) Standard: Arcor TNP 02 Conductor diameter: 0,9 mm Loop resistance: 56,6 Ω/km Resistance difference: 0,30 Ω/km Insulation resistance: L>200m 10 GΩkm 100m L 200m 25 GΩkm L<100m 30 GΩkm Mutual capacitance: 34 nf/km Capacitance unbalance: k pf/km k pf/km e a1/ pf/km Attenuation: 800 Hz 0,6 db/km Operating voltage: 250 V eff Near-end crosstalk: 45 db abs. Far-end crosstalk: 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min 42 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

43 German Railways PE-foam skin insulated, star quads, with inductive protection AJ-02YSTF(L)2YDB2Y..x4x0,9 STI A TNP 02 C34 mutual capacitance number of double cores 0,9 dimension of copper conductor TF filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km AJ-02YSTF(L)2YDB2Y 10x4x0,9 STI TNP , AJ-02YSTF(L)2YDB2Y 16x4x0,9 STI TNP , AJ-02YSTF(L)2YDB2Y 19x4x0,9 STI TNP , AJ-02YSTF(L)2YDB2Y 24x4x0,9 STI TNP , AJ-02YSTF(L)2YDB2Y 30x4x0,9 STI TNP , German Railways (DB) The cable is designed for use as railway signalling cable for long distances. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: Screening: Armouring: Protective cover: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol solid, bare copper wire 0,9 mm PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to star-quads, quads stranded together in concentric layers, 2 perforated cores ( 0,5 mm), wrapping with swellable tape (TF) aluminium laminated PE-sheath, black ((L)2Y) 1 layer copper wires (D), wrapping with tape two layers of galvanized steel tape (B), wrapping of tape PE, black (2Y) Technical Details (at 20 C) Standard: Arcor TNP 02 Conductor diameter: 0,9 mm Loop resistance: 56,6 Ω/km Resistance difference: 0,30 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance: 34 nf/km Capacitance unbalance: k pf/km k pf/km e a1/ pf/km Attenuation: 800 Hz 0,6 db/km Operating voltage: 250 V eff Near-end crosstalk: 45 db/abs. Far-end crosstalk: 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Reduction factor: according to Arcor TNP 05 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 43

44 German Railways PE-foam skin insulated, quads, inductive protection AJ-02YSTF(L)2YDB2Y..x4x1,4 /..x4x0,9 STI A TNP 02 C34 C36 mutual capacitance number of double cores dimension of conductor TF filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km AJ-02YSTF(L)2YDB2Y 1x4x1,4 / 7x4x AJ-02YSTF(L)2YDB2Y 2x4x1,4 / 11x4x AJ-02YSTF(L)2YDB2Y 3x4x1,4 / 12x4x AJ-02YSTF(L)2YDB2Y 4x4x1,4 / 13x4x AJ-02YSTF(L)2YDB2Y 5x4x1,4 / 16x4x AJ-02YSTF(L)2YDB2Y 3x4x1,4 / 30x4x The cable is designed for use as railway signalling cable for long distances. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: Screening: Armouring: Protective cover: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol solid, bare copper wire 0,9 / 1,4 mm PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to star-quads, quads stranded together in concentric layers, 2 perforated cores ( 0,5 mm), wrapping with swellable tape (TF) aluminium laminated PE-sheath, black ((L)2Y) 1 layer copper wires, wrapping with tape (D) 2 layers galvanized steel tape (B), wrapping of tape PE, black (2Y) Technical Details (at 20 C) Standard: Arcor TNP 02 Conductor diameter: 0,9 1,4 mm Loop resistance: 56,6 23,4 Ω/km Resistance difference: 0,30 0,20 Ω/km Insulation resistance: L>200m GΩkm 100m L 200m GΩkm L<100m GΩkm Mutual capacitance: nf/km Capacitance unbalance: k pf/km k pf/km e a1/ pf/km Attenuation: 800 Hz 0,6 0,4 db/km Operating voltage: V eff Near-end crosstalk: db abs. Far-end crosstalk: db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Reduction factor: according Arcor TNP Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

45 German Railways PE-foam skin insulated, star quads, with reinforced sheath A-02YS(L)2YV x4x0,7 mm² STI TNP 03 C34 mutual capacitance 6-14 number of double cores # 0,7² dimension of copper conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-02YS(L)2YV 3x4x0,7 mm² STI TNP ,0 290 A-02YS(L)2YV 5x4x0,7 mm² STI TNP ,0 420 A-02YS(L)2YV 7x4x0,7 mm² STI TNP ,0 510 German Railways (DB) The cable is designed for use as railway signalling cable for long distances, with high resistance against vibrations. The cable is fixed directly at the rail. Conductor: Insulation: Colour code : Cable make up: Screening/sheath: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol strand bare copper wire 0,7 mm² PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to quads, quads stranded together in concentric layers, 2 perforated cores (cross section 0,2 mm²), wrapping with tape tinned strand copper wire (cross section 0,2 mm²), one layer aluminium tape, PE-sheath black, reinforced ((L)2YV) Technical Details (at 20 C) Standard: Arcor TNP 03 Conductor cross section: 0,7 mm² Loop resistance: 56,6 Ω/km Resistance difference: 0,30 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance: 34 nf/km Capacitance unbalance: k pf/km k pf/km e a1/ pf/km Attenuation: 800 Hz 0,6 db/km Operating voltage: 250 V eff Near-end crosstalk: 45 db/abs. Far-end crosstalk: 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Copper wire resistance: 95 Ω/km Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 45

46 German Railways PE-foam skin insulated, star-quads, with rodent protection A-02YS(L)2YB2Y..x4x0,7mm² STI TNP 03 C34 mutual capacitance 6-14 number of double cores # 0,7² dimension of conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores (DC) approx. mm approx. kg/km A-02YS(L)2YB2Y 3x4x0,7mm² 6 24,0 500 A-02YS(L)2YB2Y 5x4x0,7mm² 10 28,0 660 A-02YS(L)2YB2Y 7x4x0,7mm² 14 30,0 790 The cable is designed for use as railway signalling cable for long distances, with high resistance against vibrations. The cable is fixed directly at the rail. Conductor: Insulation: Colour code : Cable make up: Sheath: Armouring: Protective cover: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol strand bare copper wire 0,7 mm² PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to quads, quads stranded together in concentric layers, 2 perforated cores (0,2 mm²), wrapping with tape. tinned copper wire (0,2mm²), one layer aluminium tape, PE-sheath, black ((L)2Y) one layer of galvanized steel tape (B) PE, black (2Y) Technical Details (at 20 C) Standard: Arcor TNP 03 Conductor diameter: 0,7 mm² Loop resistance: 56,6 Ω/km Resistance difference: 0,30 Ω/km Insulation resistance: L>200m 10 GΩkm 100m L 200m 25 GΩkm L<100m 30 GΩkm Mutual capacitance: 34 nf/km Capacitance unbalance: k pf/km k pf/km e a1/ pf/km Attenuation: 800 Hz 0,6 db/km Operating voltage: 250 V eff Near-end crosstalk: 45 db abs. Far-end crosstalk: 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω. abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Copper wire resistance: 95 Ω/km 46 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

47 German Railways PE-foam skin insulated, star quads, with rodent protection A-02YS(L)2Y(SR)2Y x4x0,7 mm² STI TNP 03 C34 mutual capacitance 6-14 number of double cores # 0,7² dimension of copper conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-02YS(L)2Y(SR)2Y 3x4x0,7 mm² STI TNP ,0 500 A-02YS(L)2Y(SR)2Y 5x4x0,7 mm² STI TNP ,0 660 A-02YS(L)2Y(SR)2Y 7x4x0,7 mm² STI TNP ,0 790 German Railways (DB) The cable is designed for use as railway signalling cable for long distances, with high resistance against vibrations. The cable is fixed directly at the rail. Conductor: Insulation: Colour code : Cable make up: Sheath: Armouring: Protective cover: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol strand bare copper wire 0,7 mm² PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to quads, quads stranded together in concentric layers, 2 perforated cores (cross section 0,2 mm²), wrapping with tape tinned strand copper wire (cross section 0,2 mm²), one layer aluminium tape, PE-sheath black ((L)2Y) one layer corrugated steel tape ((SR)) PE, black (2Y) Technical Details (at 20 C) Standard: Arcor TNP 03 Conductor cross section: 0,7 mm² Loop resistance: 56,6 Ω/km Resistance difference: 0,30 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance: 34 nf/km Capacitance unbalance: k pf/km k pf/km e a1/ pf/km Attenuation: 800 Hz 0,6 db/km Operating voltage: 250 V eff Near-end crosstalk: 45 db/abs. Far-end crosstalk: 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Copper wire resistance: 95 Ω/km Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 47

48 German Railways PE-foam skin insulated, star-quads, with strain relief elements A-02YS2Y(ST)(ZN)2Y..x4x0,9mm STI TNP 04 C34 mutual capacitance number of double cores 0.9 dimension of conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-02YS2Y(ST)(ZN)2Y 5x4x0,9mm 10 21,1 354,5 A-02YS2Y(ST)(ZN)2Y 7x4x0,9mm 14 22,8 434,1 A-02YS2Y(ST)(ZN)2Y 10x4x0,9mm 20 27,1 569,3 A-02YS2Y(ST)(ZN)2Y 12x4x0,9mm 24 28,4 660,1 A-02YS2Y(ST)(ZN)2Y 16x4x0,9mm 32 31,9 839,8 The cable is designed for use as railway signalling cable for long distances, only for overground laying and mounting poles. Conductor: Insulation: Colour code : Cable make up: Sheath: Screening: Strain relief/ Protective cover: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol solid bare copper wire 0,9 mm PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to quads, quads stranded together in concentric layers, 2 perforated cores ( 0,5 mm), wrapping with tape. PE, natural (2Y) tinned copper wire ( 0,4 mm), one layer aluminium tape ((ST)) Glasrovings/ PE, black ((ZN)2Y) Technical Details (at 20 C) Standard: Arcor TNP 04 Conductor diameter: 0,9 mm² Loop resistance: 56,6 Ω/km Resistance difference: 0,30 Ω/km Insulation resistance: L>200m 10 GΩkm 100m L 200m 25 GΩkm L<100m 30 GΩkm Mutual capacitance: 34 nf/km Capacitance unbalance: k pf/km k pf/km e a1/ pf/km Attenuation: 800 Hz 0,6 db/km Operating voltage: 250 V eff Near-end crosstalk: 45 db abs. Far-end crosstalk: 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Copper wire resistance: 140 Ω/km 48 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

49 German Railways PE-foam skin insulated, star-quads, with reinforced sheath A-02YSF(L)2YV 2x4x1,4 / 2x4x0,9 STI TNP 06 C34 C36 mutual capacitance 8 number of double cores dimension of conductor F filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-02YSF(L)2YV 2x4x1,4 / 2x4x German Railways (DB) The cable is designed for use as railway signalling cable, preferable for the connection of railway connection boxes. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol solid, bare copper wire 0,9 / 1,4 mm PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to star-quads, quads stranded together in concentric layers, 2 perforated cores ( 0,5 mm), filled with petrolat (F), wrapping with tape, wrapping with swellable tape aluminium laminated, reinforced PE-sheath, black ((L)2YV) Technical Details (at 20 C) Standard: Arcor TNP 06 Conductor diameter: 0,9 1,4 mm Loop resistance: 56,6 23,4 Ω/km Resistance difference: 0,30 0,20 Ω/km Insulation resistance: L>200m GΩkm 100m L 200m GΩkm L<100m GΩkm Mutual capacitance: nf/km Capacitance unbalance: k pf/km k pf/km e a1/ pf/km Attenuation: 800 Hz 0,6 0,4 db/km Operating voltage: V eff Near-end crosstalk: db abs. Far-end crosstalk: db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 49

50 German Railways PE-foam skin insulated, star-quads, with rodent protection A-02YSF(L)2Y(SR)2Y 3x4x0,9mm STI TNP 06 C34 mutual capacitance 6 number of double cores 0.9 dimension of conductor F filling cable elements overall shield, armouring Type number of outer diameter weight double cores (DC) approx. mm approx. kg/km A-02YSF(L)2Y(SR)2Y 3x4x0,9mm 6 20,0 350 The cable is designed for use as railway signalling cable, preferable for theconnection of railway connection boxes. Useable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: Armouring: Protective cover: 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol solid bare copper wire 0,9 mm PE-Foam skin (02YS) a core: YE b core: RD c core: GN d core: BU cores twisted to quads, quads stranded together in concentric layers, 2 perforated cores ( 0,5 mm), filled with petrolat (F), wrapping with tape, wrapping with swellable tape aluminium laminated PE-sheath, black ((L)2Y) one layer of corrugated steel tape ((SR)) PE, black (2Y) Technical Details (at 20 C) Standard: Arcor TNP 06 Conductor diameter: 0,9 mm² Loop resistance: 56,6 Ω/km Resistance difference: 0,30 Ω/km Insulation resistance: L>200m 10 GΩkm 100m L 200m 25 GΩkm L<100m 30 GΩkm Mutual capacitance: 34 nf/km Capacitance unbalance: k pf/km k pf/km e a1/ pf/km Attenuation: 800 Hz 0,6 db/km Operating voltage: 250 V eff Near-end crosstalk: 45 db abs. Far-end crosstalk: 45 db/km conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Characteristics of monitoring cores: Loop resistance: 190 Ω/km Insulation resistance: dry cable 1 GΩkm drown cable 30 kω abs. conductor/conductor 500 V/50Hz/1min conductor/shield 2000 V/50Hz/1min 50 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

51 German Railways PE insulated, star-quads, with rodent protection A-2Y(L)2YB2Y 1x4x mutual capacitance 2 number of double cores 1,4 1,53 dimension of copper conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-2Y(L)2YB2Y 1x4x1,4 2 14,0 260 A-2Y(L)2YB2Y 1x4x1, ,0 350 German Railways (DB) The cable is designed for use in signal systems (unless the application of special cables of signaltechnique is required), preferably for transmission of alternating currents in systems which needs a high symmetry against each other. Conductor: Insulation: Colour code : Cable make up: Screening: Armouring: Protective cover: solid, bare copper wire 1,4 / 1,53 mm PE (2Y) a core: transparent b core: transparent with one ring mark every 17 mm c core: transparent with two ring marks every 34 mm d core: transparent with two ring marks every 17 mm cores twisted to a quad, wrapping with tape one copper wire ( 0,4mm), aluminium laminated PEsheath, black ((L)2Y), one layer steel tape, galvanized (B) PE, black (2Y) SIGNAL / Eurobalise (alternating every 25 cm) - type - VDE reg. nr. - PENGG KABEL - <meter> Technical Details (at 20 C) Standard: DB AG Conductor diameter: 1,4 1,53 mm Loop resistance: 23,4 19,8 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance: nf/km Capacitance unbalance: k pf/km e a1/ pf/km Operating voltage: DC V AC V/100 Hz Near-end crosstalk: db Attenuation: 560 khz 7 4,2 db/km Impedance: khz 120+/-10% 120+/-10% Ω conductor/conductor V/50Hz/1min conductor/shield V/50Hz/1min Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 51

52 German Railways PE-insulated, star-quads, with inductive protection AJ-2Y(L)2YDB2Y 1x4x1,53 C43 mutual capacitance 2 number of double cores 1.53 dimension of conductor filling cable elements overall shield, armouring Type number of index of inductive- outer diameter weight double cores protection rk (f=16 2/3 Hz) approx. mm approx. kg/km AJ-2Y(L)2YDB2Y 1x4x1, ,0 740 AJ-2Y(L)2YDB2Y 1x4x1, ,0 830 AJ-2Y(L)2YDB2Y 1x4x1, , The cable is designed for use in signal systems (unless the application of special cables of signaltechnique is required), preferably for transmission of alternating currents in systems which needs a high symmetry against each other. Conductor: Insulation: Colour code : Cable make up: 1st Screening: 2nd Screening: Armouring: Protective cover: solid, bare copper wire 1,53 mm PE (2Y) a core: transparent b core: transparent with one ring mark every 17 mm c core: transparent with two ring marks every 34 mm d core: transparent with two ring marks every 17 mm cores twisted to a quad, wrapping with tape one copper wire ( 0,4mm), aluminium laminated PEsheath, black ((L)2Y) one layer copper wires, wrapping with tape (D) two layer steel tape, galvanized (B) PE, black (2Y) SIGNAL / Eurobalise (alternating every 25 cm) - type - VDE reg. nr. - PENGG KABEL - <meter> Technical Details (at 20 C) Standard: DB AG Conductor diameter: 1,53 mm Loop resistance: 19,8 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance: 43 nf/km Capacitance unbalance: k pf/km e a1/2 650 pf/km Operating voltage: DC 600 V AC 420 V/100 Hz Near-end crosstalk (1 MHz): 60 db Attenuation: 8,8 khz 0,8 db/km 280 khz 3,0 db/km 560 khz 4,2 db/km 1,8 MHz 8,0 db/km Impedance: 8,8 khz 147+/-15% Ω khz 120+/-10% Ω 1,8 MHz 120+/-10% Ω Reduction factor: acc. to DB AG Temperature range during operation -40 up to +60 C during installation -10 up to +60 C 52 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

53 German Railways PE-insulated, star-quads, reinforced sheath A-2YF(L)2Y..x4x0,4 STIII BD C50 mutual capacitance number of double cores 0.4 dimension of conductor F filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km A-2YF(L)2Y 6x2x0.4 STIII BD A-2YF(L)2Y 10x2x0.4 STIII BD A-2YF(L)2Y 20x2x0.4 STIII BD A-2YF(L)2Y 30x2x0.4 STIII BD A-2YF(L)2Y 40x2x0.4 STIII BD A-2YF(L)2Y 50x2x0.4 STIII BD A-2YF(L)2Y 70x2x0.4 STIII BD A-2YF(L)2Y 100x2x0.4 STIII BD A-2YF(L)2Y 150x2x0.4 STIII BD A-2YF(L)2Y 200x2x0.4 STIII BD German Railways (DB) The cable is designed for transmission of railway station signals. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: Cable short mark: solid, bare copper wire 0,4 mm PE (2Y) a core: transparent b core: transparent with one ring mark every 17 mm c core: transparent with two ring marks every 34 mm d core: transparent with two ring marks every 17 mm cores twisted to quads, quads stranded together in concentric layer, filled with petrolat (F), wrapping with tape aluminium laminated PE-sheath, black ((L)2Y) star-quad stranding (STIII) bundle stranding (BD) Technical Details (at 20 C) Standard: Dlk Conductor diameter: 0,4 mm Conductor loop resistance: 300 Ω/km Insulation resistance: 5 GΩkm Mutual capacitance (800Hz): 100% 50 nf/km 95% 48 nf/km Capacitance unbalance: k 1 100% 800 pf/300m k 1 98% 400 pf/300m k % 300 pf/300m k % 100 pf/300m Attenuation: 800 Hz 1,49 db/km conductor/shield 2000 V/50Hz/2min 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 53

54 German Railways PE-foam skin insulated, star-quads A-02YSF(L)2Y..x2x.. STIII BD C42 C42 mutual capacity number of double cores dimension of conductor F filling cable elements overall shield, armouring conductor diameter 0.6 mm conductor diameter 0.8 mm Type number of outer diameter weight outer diameter weight double cores approx mm approx. kg/km approx. mm approx. kg/km A-02YSF(L)2Y 6x2x ,3 107,5 13,2 176,9 A-02YSF(L)2Y 10x2x ,8 147,3 15,3 252,0 A-02YSF(L)2Y 20x2x ,3 255,2 20,0 450,3 A-02YSF(L)2Y 30x4x ,6 350,6 22,7 601,6 A-02YSF(L)2Y 40x4x ,6 443,2 25,4 755,1 A-02YSF(L)2Y 50x4x ,3 532,1 28,2 952,6 A-02YSF(L)2Y 70x4x ,8 730,2 32,3 1273,9 A-02YSF(L)2Y 100x4x ,6 991,7 38,8 1823,4 A-02YSF(L)2Y 200x4x ,2 1876,5 51,8 3301,0 The cable is designed for transmission of railway station signals. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: Cable short mark: solid, bare copper wire PE - foam skin (02YS) a core: transparent b core: transparent with one ring mark every 17 mm c core: transparent with two ring marks every 34 mm d core: transparent with two ring marks every 17 mm cores twisted to quads, quads stranded together in concentric layers, filled with petrolat (F), wrapping with tape aluminium laminated PE-sheath, black ((L)2Y) star-quad stranding (STIII) bundle stranding (BD) 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol Technical Details (at 20 C) Standard: Dlk Conductor diameter: 0,6 0,8 mm Conductor loop resistance: ,2 Ω/km Insulation resistance: 5 5 GΩkm Mutual capacitance (800Hz): 100% nf/km 95% nf/km 80% nf/km Capacitance unbalance: k 1 100% pf/300m k1 98% pf/300m k % pf/300m k % pf/300m Attenuation: 800 Hz 0,91 0,69 db/km Dielectric strength conductor/conductor V/50Hz/2min conductor/shield V/50Hz/2min Operating peak voltage: V 54 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

55 German Railways PE-foam skin insulated, star-quads, with inductive protection AJ-02YSF(L)2YDB2Y..x2x0,8 STIII BD C42 mutual capacitance number of double cores 0,8 dimension of copper conductor F filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km AJ-02YSF(L)2YDB2Y 10x2x0.8 STIII BD 10 24,2 1070,8 AJ-02YSF(L)2YDB2Y 20x2x0.8 STIII BD 20 29,1 1486,0 AJ-02YSF(L)2YDB2Y 30x2x0.8 STIII BD 30 31,9 1821,7 AJ-02YSF(L)2YDB2Y 40x2x0.8 STIII BD 40 35,3 2203,5 AJ-02YSF(L)2YDB2Y 50x2x0.8 STIII BD 50 38,7 2525,8 AJ-02YSF(L)2YDB2Y 70x2x0.8 STIII BD 70 45,0 3626,5 AJ-02YSF(L)2YDB2Y 100x2x0.8 STIII BD ,2 4517,7 AJ-02YSF(L)2YDB2Y 200x2x0.8 STIII BD ,3 6985,5 German Railways (DB) The cable is designed for transmission of railway station signals. Usable for underground laying and drawing into conduits. Conductor: Insulation: Colour code : Cable make up: Sheath: Screening: Armouring: Protective Cover: Cable short mark: solid, bare copper wire PE - foam skin (02YS) a core : transparent b core : transparent with one ring mark every 17 mm c core : transparent with two ring marks every 34 mm d core : transparent with two ring marks every 17 mm cores twisted to quads, quads stranded together in concentric layers, filled with petrolat (F), wrapping with tape aluminium laminated PE-sheath, black ((L)2Y) one layer copper wires (D), wrapping with tape two layers of steel tape (B) PE, black (2Y) star-quad stranding (STIII) bundle stranding (BD) 1. line: handset symbol - <meter> 2. line: ( >20mm) handset symbol Technical Details (at 20 C) Standard: Dlk Conductor diameter: 0,8 mm Conductor loop resistance: 73,2 Ω/km Insulation resistance: 5 GΩkm Mutual capacitance (800Hz): 100% 42 nf/km 95% 40 nf/km 80% 38 nf/km Capacitance unbalance k 1 100% 800 pf/300m k 1 98% 400 pf/300m k % 300 pf/300m k % 100 pf/300m Attenuation: 800 Hz 0,69 db/km Dielectric strength conductor/conductor 500 V/50Hz/2min conductor/shield 2000 V/50Hz/2min Operating peak voltage: 225 V Reduction factor: acc. Dlk and Dlk Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 55

56 German Railways Note 56 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

57 French Railways, SNCF ZPAU - px ² page 58 MD4 x4x0,8 page 59 ZPFU-...px1² page 60 ZUG-S...P...² page 61 ZUT-S...P...² page 62 4D... page 63 French Railways (SNCF) Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 57

58 French Railways PE insulated, pairs, with inductive protection ZPAU - px ² mutual capacity 1-56 number of double cores # 1² # 2,5² dimension of conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km ZPAU 1px2,5² 1 21,2 763 ZPAU 4px1² 4 23,8 620 ZPAU 7px1² 7 26,7 944 ZPAU 14px1² 14 31, ZPAU 21px1² 21 35, ZPAU 28px1² 28 39, ZPAU 56px1² 56 49, The cable is designed for the connection of the control center to the equipment shelters. Conductor: Insulation: Colour code: Cable make up: Sheath: Screening: Armouring: Protective cover: solid, bare copper wire PE a core: transparent b core: BK - BE - YE - RD - GN cores twisted to pairs., pairs stranded together to the cable core, wrapping with tape PE, transparent one layer copper tape; PE transparent two layers steel tape PE, black type - CT PENGG KABEL - month/year of production - <meter> - RESEAU FERRE DE FRANCE Technical Details (at 20 C) Standard: SNCF CT 445 Conductor cross section: 1 2,5 mm² Conductor resistance: 18,1 7,41 Ω/km Insulation resistance: 5 5 GΩkm Mutual capacitance: 1000 (+/-200) Hz 55 nf/km 8,9 khz 45 nf/km Capacitance unbalance: pf/500m Reduction factor: according to SNCF CT 445 Attenuation: 45 khz 2,5 db/km 560 khz 3,8 db/km Impedance: 800Hz 120+/-10 Ω 8,9 khz 130+/-10 Ω conductor/conductor 3000 V/DC/3min conductor/shield 3000 V/DC/3min 58 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

59 French Railways PE-foam skin insulated, star quads, with inductive protection MD4 x4x0,8 C49 mutual capacity number of double cores 0.8 dimension of conductor F filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km MD4 7x4x0, ,7 773 MD4 14x4x0, , MD4 21x4x0, , MD4 28x4x0, , The cable is designed for long distance telecommunications alongside railway lines. Conductor: Insulation: Colour code: Cable make up: Sheath: Armouring: Protective cover: solid, bare copper wire 0,8 mm PE-foam skin a core: GY - OG b core: WH - YE - BK - GN - BU - BN - RD c core: VT d core: BU - BN - RD - WH - YE - BK - GN cores twisted to pairs, pairs cabled together to a bundel, bundels stranded to the cable core, wrapping with tape petrol jelly, one tinnend copper wire, wrapping with tape; PE transparent two layers steel tape, wrapping with tape PE, black <meter> - "RFF" - type - "2328" - "ed4"- PENGG KABEL - year of production Technical Details (at 20 C) Standard: SNCF TL DCG N 2328 Ed.04 Conductor diameter: 0,8 mm Conductor resistance: 35,6 Ω/km Insulation resistance: 15 GΩkm Mutual capacitance (at f=800hz): 49 nf/km max 51 nf/km min 46 nf/km Capacitance unbalance: k 1 50 pf/1450m max 340 pf/1450m k pf/1450m max 340 pf/1450m e a1/2 200 pf/1450m max 1025 pf/1450m Reduction factor: acc. to SNCF TL DCG N 2328 Ed.04 Attenuation: 1MHz 15,9 db/km Impedance: 800Hz 520+/-10% Ω/km conductor/conductor 1500 V/DC/1min conductor/shield 3000 V/DC/1min conductor/shield 3750 V/DC/3sek French Railways (SNCF) Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 59

60 French Railways PE insulated, pairs, with armouring ZPFU - px1² C 55 mutual capacity 1-56 number of double cores # 1² dimension of conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km ZPFU 1px1² 1 12,5 186 ZPFU 1px1² 2 13,6 248 ZPFU 4px1² 4 17,3 369 ZPFU 7px1² 7 20,8 695 ZPFU 14px1² 14 27, ZPFU 21px1² 21 29, ZPFU 28px1² 28 33, ZPFU 56px1² 56 43, The cable is designed for the connection of the control center to the equipment shelters. Conductor: Insulation: Colour code: Cable make up: Sheath: Armouring: Protective cover: solid, bare copper wire PE a core: transparent b core: BK - BE - YE - RD - GN cores twisted to pairs, pairs stranded together to the cable core, wrapping with tape PE, transparent two layers steel tape, wrapping with tape PE, black type - CT PENGG KABEL - month/year of production - <meter> - PRO- PRIETE RFF Technical Details (at 20 C) Standard: SNCF CT 445 Conductor cross section: 1 mm² Conductor resistance: 18,1 Ω/km Insulation resistance: 5 GΩkm Mutual capacitance: 1000 (+/-200) Hz 55 nf/km Capacitance unbalance: 200 pf/500m Attenuation: 45 khz 2,5 db/km Impedance: 800Hz 120+/-10 Ω conductor/conductor 3000 V/DC/3min conductor/shield 3000 V/DC/3min 60 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

61 French Railways PVC insulated, pair stranded ZUG-S P ² mutual capacity 1-12 number of double cores # 0,38² # 1² dimension of conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km ZUG-S 1P1² 1 6,8 58 ZUG-S 3P1² 3 9,4 113 ZUG-S 6P1² 6 12,3 201 ZUG-S 12P1² 12 15,9 357 ZUG-S 28P0,38² 28 15,7 335 The cable is designed for connection of railway network equipments in the traffic control center. Conductor: Insulation: Colour code: Cable make up: Sheath: strand tinned copper wire PVC a core: WH b core: BK - BU - YE -BN - RD - GN cores twisted to pairs, pairs stranded together to the cable core, wrapping with tape PVC, black Technical Details (at 20 C) Standard: SNCF CT 455 Conductor cross section: 0,38 1 mm² Loop resistance: 20,1 52,5 Ω/km conductor/conductor V/50Hz/3min French Railways (SNCF) type - CT PENGG KABEL - month and year of production - <meter> Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 61

62 French Railways PVC insulated, star-quad, with inductive protection ZUT-S P ² mutual capacity 2-12 number of double cores # 1² dimension of conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km ZUT-S 2P1² 2 8,2 134 ZUT-S 6P1² 6 14,0 280 ZUT-S 12P1² 12 18,0 445 The cable is designed for connection of railway network equipments in the traffic control center. Conductor: Insulation: Colour code: Cable make up: Screening: Sheath: strand tinned copper wire PVC a core: WH b core: BK c core: YE d core: BU cores twisted to a quad, wrapping with tape tinned copper netting (8x0,2mm), wrapping with tape PVC, black Technical Details (at 20 C) Standard: SNCF CT 455 Conductor cross section: 1 mm² Loop resistance: 52,5 Ω/km conductor/conductor 2500 V/50Hz/3min type - CT PENGG KABEL - month and year of production - <meter> 62 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

63 French Railways PE insulated, star quads, with rodent protection 4D C50 mutual capacity 8-28 number of double cores 0.8 dimension of conductor F filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km 4 D , D , D ,6 821 The cable is designed for long distance telecommunications alongside railway lines. Conductor: Insulation: Colour code: Cable make up: Sheath: Armouring: Protective cover: solid, bare copper wire 0,8 mm PE a core: GY - OG b core: WH - YE - BK - GN - BU - BN - RD c core: VT d core: BU - BN - RD - WH - YE - BK - GN cores twisted to quads, quads stranded together to concentric layers filled with petrolat, wrapping with tape, one tinnend copper wire, wrapping with tape; PE, transparent two layers steel tape, filled with petrolat, wrapping with tape PE, black <meter> - "SNCF" - type - "2329" - "ed0"- PENGG KABEL - year of production Technical Details (at 20 C) Standard: SNCF CT AFT N 2329 Ed.0 Conductor diameter: 0,8 mm Conductor resistance: 36,7 Ω/km Insulation resistance: 15 GΩkm Mutual capacitance (at f=800hz): 50 nf/km max: 54 nf/km min: 46 nf/km Capacitance unbalance: k 1 40 pf/300m max 200 pf/300m k pf/300m max 75 pf/300m e a1/2 130 pf/300m max 1600 pf/300m conductor/conductor 1500 V/DC/1min conductor/shield 3000 V/DC/1min conductor/shield 3750 V/DC/3sek French Railways (SNCF) Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 63

64 French Railways Note 64 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

65 Swiss Railways, SBB PE4-ALT-CLT...x4x... page 66 Sw-Kabel...x4x... CLT page 67 PE-ALT-CLT 1x4x1,53 page 68 Swiss Railways (SBB) Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 65

66 Swiss Railways Foam-skin PE insulated, star-quads, with rodent protection PE4-ALT-CLT...x4x C40 mutual capacity number of double cores 0,8 1,0 dimension of conductor filling cable elements overall shield, armouring conductor diameter 0,8 mm conductor diameter 1,0 mm Type number of outer diameter weight outer diameter weight double cores approx. mm approx. kg/km approx. mm approx. kg/km PE4-ALT-CLT 1x4x , PE4-ALT-CLT 3x4x , PE4-ALT-CLT 5x4x , ,8 541 PE4-ALT-CLT 10x4x , ,3 923 PE4-ALT-CLT 20x4x , , PE4-ALT-CLT 30x4x , , PE4-ALT-CLT 50x4x , , The cable is desigend for general use in railway telecommunication systems. Conductor: Insulation: Colour code : Cable make up: Sheath: Armouring: Protective cover: solid, bare copper wire 0,8 / 1,0 mm foam-skin PE (PE4) a core: WH b core: OG - GN - BN - GY c core: TQ d core: VT cores twisted to quads, quads stranded together in concentric layer, wrapping with tape one or two drain wires; aluminium laminated PEsheath, black (ALT) two layers galvanized steel tape (CL) PE, black (T) PENGG KABEL - year of procution - type - order number - "=>" (arrow from the red end) - <meter> Technical Details (at 20 C) Standard: SBB I-PS Conductor diameter: 0,8 1,0 mm Loop resistance: 73,5 47,0 Ω/km Insulation resistance: GΩkm Mutual capacitance: nf/km Capacitance unbalance: k 1 100% pf/km abs pf/km k pf/km abs pf/km e a1/ pf/km abs pf/km conductor/conductor 2000 V/50Hz/1min conductor/shield 2000 V/50Hz/1min Temperatur range: during installation -5 to +50 C 66 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

67 Swiss Railways PE insulated, star-quads, with rodent protection Sw-Kabel x4x CLT mutual capacity 2-60 number of double cores 1,5 2,2 dimension of conductor filling cable elements overall shield, armouring conductor diameter 1,5 mm conductor diameter 2,2 mm Type number of outer diameter weight outer diameter weight double cores approx. mm approx. kg/km approx. mm approx. kg/km Sw-Kabel 1x4x... CLT 2 15, ,5 342 Sw-Kabel 3x4x... CLT 6 23, ,0 930 Sw-Kabel 5x4x... CLT 10 28, , Sw-Kabel 10x4x... CLT 20 36, , Sw-Kabel 15x4x... CLT 30 41, , Sw-Kabel 20x4x... CLT 40 46, , Sw-Kabel 25x4x... CLT 50 52, , Sw-Kabel 30x4x... CLT 60 55, , The cable is designed for general use in protection systems with an operating voltage 500 Veff (16 2/3 Hz) or 800 V DC. Conductor: Insulation: Colour code : Cable make up: Sheath: Armouring: Protective cover: solid, bare copper wire 1,5 / 2,2 mm PE a core: WH b core: OR - GN - BN - GY c core: TQ d core: VT cores twisted to quads, quads stranded together in concentric layers, wrapping with tape PE, black two layers galvanized steel tape (CL) PE, black (T) SIGNAL - "=>" (arrow from the red end) - PENGG KABEL - year of production - order number - <meter> Technical Details (at 20 C) Standard: SBB I-PS Conductor diameter: 1,5 2,2 mm Loop resistance: 20,9 10,0 Ω/km Insulation resistance: GΩkm Mutual capacitance: nf/km Capacitance unbalance: k pf/km k pf/km e a1/ pf/km conductor/conductor 2000 V/50Hz/1min conductor/shield 4000 V/50Hz/1min Swiss Railways (SBB) Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 67

68 Swiss Railways PE insulated, star-quads, with inductive protection PE-ALT-CLT 1x4x1,53mm C42 mutual capacity 2 number of double cores 1,53 dimension of conductor filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km PE-ALT-CLT 1x4x1, ,2 292 The cable is designed for the connection of ETCS-Balisen. Conductor: Insulation: Colour code : Cable make up: Sheath: Armouring: Protective cover: solid, bare copper wire 1,53 mm PE (PE) a core: WH b core: OR c core: TQ d core: VT cores twisted to a quad, wrapping with tape two drain wires; aluminium laminated PE-sheath, black (ALT) two layers galvanized steel tape (CL) PE, black (T) SIGNAL - PENGG KABEL - year of prodcution - type - order number - <meter> Technical Details (at 20 C) Standard: SBB I-PS Conductor diameter: 1,53 mm Loop resistance: 19,8 Ω/km Insulation resistance: 10 GΩkm Mutual capacitance: max 48,6 nf/km min 35,9 nf/km Attenuation: 1,8 MHz 0,8 db/100m Impedance: 1,8 MHz 120+/-5% Ω Capacitance unbalance: k pf/km e a1/2 640 pf/km conductor/conductor 2500 V/50Hz/1min conductor/shield 2500 V/50Hz/1min Temperature range: during installation -5 to +50 C 68 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

69 Hungarian Railways, MAV AJ-02YSF(L)2YD2Y...x4x0,8 (HvrQ) page 70 AJ-2Y(L)2YLB2Y...x... (BRQA) page 71 Hungarian Railways (SBB) Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 69

70 Hungarian Railway Cables PE-foam skin insulated, star quads, with inductive protection AJ-02YSF(L)2YD2Y x4x0,8 (HvrQ) C42 mutual capacity number of double cores 0,8 dimension of conductor F filling cable elements overall shield, armouring Type number of outer diameter weight double cores approx. mm approx. kg/km AJ-02YSF(L)2YD2Y 1x4x0,8 (HvrQ) 2 15,0 350 AJ-02YSF(L)2YD2Y 5x4x0,8 (HvrQ) 10 21,0 690 AJ-02YSF(L)2YD2Y 10x4x0,8 (HvrQ) 20 27, AJ-02YSF(L)2YD2Y 15x4x0,8 (HvrQ) 30 29, AJ-02YSF(L)2YD2Y 25x4x0,8 (HvrQ) 50 36, AJ-02YSF(L)2YD2Y 50x4x0,8 (HvrQ) , AJ-02YSF(L)2YD2Y 75x4x0,8 (HvrQ) , AJ-02YSF(L)2YD2Y 100x4x0,8 (HvrQ) , The cable is designed for underground laying and drawing into conduits for local networks. Conductor: Insulation: Colour code : Cable make up: Filling: Sheath: Screening: Protective cover: solid, bare copper wire 0,8 mm PE foam skin (02YS) a core: RD - GN - YE - BU - BN b core: WT c core: BK d core: GY cores twisted to quads, 5 quads cabled together to basic strands, basic strands cabeld together in concentric layer ( 50 quads); for cables 75 quads, 5 basic strands cabeld together to primary strands and cabeld together in concentric layers filled with petrol jelly (F), wrapping with tape aluminium laminated PE-sheath, black ((L)2Y) 1 layer copper wires ( 1,4 mm) (D), wrapping with tape PE, black (2Y) Technical Details (at 20 C) Standard: costumer specification MAV P-2518/2002 Conductor diameter: 0,8 mm Loop resistance: 73,2 Ω/km Insulation resistance: 5 GΩkm Mutual capacitance: 42 nf/km Capacitance unbalance: k 1 100% 800 pf/300m 50% 400 pf/300m k % 300 pf/300m 50% 400 pf/300m e a1/2 100% 800 pf/300m conductor/conductor 500 V/50Hz/2min conductor/shield 2000 V/50Hz/2min Temperature range: during installation: -5 to +70 C during operation: -30 to +70 C MÀV ZRt. - handset symbol - <meter> - type - PENGG KABEL - year of procution - CE - order number 70 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

71 Hungarian Railway Cables PE-insulated, single core, with rodent protection AJ-2Y(L)2YLB2Y x (BRQA) mutual capacity 2-91 number of cores 1,0 1,5 dimension of conductor filling cable elements overall shield, armouring conductor diameter 1,0 mm conductor diameter 1,5 m Type number of outer diameter weight outer diameter weight cores approx. mm approx. kg/km approx. mm approx. kg/km AJ-2Y(L)2YLB2Y 2x , ,2 310 AJ-2Y(L)2YLB2Y 4x , ,1 443 AJ-2Y(L)2YLB2Y 7x , ,6 547 AJ-2Y(L)2YLB2Y 10x , ,1 676 AJ-2Y(L)2YLB2Y 14x , ,1 782 AJ-2Y(L)2YLB2Y 21x , , AJ-2Y(L)2YLB2Y 30x , , AJ-2Y(L)2YLB2Y 37x , , AJ-2Y(L)2YLB2Y 48x , , AJ-2Y(L)2YLB2Y 61x , , AJ-2Y(L)2YLB2Y 75x , , AJ-2Y(L)2YLB2Y 91x , , The cable is designed for connection of Station signal-safty equipments. Cables can be burried directly into ground or can be laid in cable ducts, tubes and indoor. Conductor: solid, bare copper wire 1,0 / 1,5 mm Insulation: PE (2Y) Colour code : beginning core: red pilot core: blue other cores: nature or black Cable make up: cores are stranded in concentric layers; neighbouring layers must be stranded in opposite direction, wrapping with tape Sheath: aluminium laminated PE-sheath, black ((L)2Y) Screening: one layer aluminium tape (L) Armouring: two layer galvanized steel tape (B) Protective cover: PE, black (2Y) Technical Details (at 20 C) Standard: P-12440/ techn. Changes Conductor diameter: 1,0 1,5 mm Conductor resistance: 23,39 10,03 Ω/km Insulation resistance: GΩkm Reduction factor: P-12440/ techn. Changes conductor/conductor 2000 V/50Hz/2min conductor/screening 2000 V/50Hz/2min Hungarian Railways (SBB) PENGG KABEL - year of production - type - MAV Zrt. - <meter> - CE - order number Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 71

72 Hungarian Railway Cables Note 72 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

73 Slovenian Railways, SZ SPZ...x... page 74 Slovenian Railways (SZ) Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 73

74 Slovenian Railways PVC insulated, single core, with rodent protection SPZ x mutual capacity number of cores 0,9 1,4 dimension of conductor filling cable elements overall shield, armouring conductor diameter 0,9 mm conductor diameter 1.4 mm Type number of outer diameter weight outer diameter weight cores approx mm approx. kg/km approx. mm approx. kg/km SPZ 4 x , ,9 294 SPZ 5 x , ,6 322 SPZ 8 x , ,9 402 SPZ 10 x , ,4 488 SPZ 12 x , ,8 535 SPZ 16 x , ,1 691 SPZ 21 x , ,4 771 SPZ 24 x , ,2 965 SPZ 27 x , , SPZ 33 x , , SPZ 40 x , , SPZ 48 x , , SPZ 61 x , , SPZ 80 x , , SPZ 108 x , , SPZ 133 x , , The cable is designed for connection of Station signal-safety equipments on electrified main railways single-phase system of 25 kv, 50 Hz and D.C. system of 3 kv. Cables can be burried directly into ground or can be laid in cable ducts, tubes and indoor. Conctructions with different Number of wires are also allowed in acc. to agreement with producer and buyer. Conductor: solid, bare copper wire 0,9 / 1,4 mm Insulation: PVC (P) Colour code : starting wire in outer layer : red starting wire in other layers : blue all other wires: grey Cable make up: cores are stranded in concentric layers; Neighbouring layers must be stranded in opposite direction, wrapping with tape Sheath: PVC, black Armouring: one layer galvanized steel tape (Z) Protective cover: PVC, black Technical Details (at 20 C) Standard: JZS S2.011 / 2009 Conductor diameter: 0,9 1,4 mm Conductor resistance: 28,9 11,9 Ω/km Insulation resistance: 5 5 Ωkm Mutual capacitance: nf/km Dielectric strength (cond./cond.) V/50Hz/1min Temperature range: during installation -5 to +70 C during operation up to +60 C <meter> - type- JZS S PENGG KABEL 74 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

75 Fiber Optic Cables A-DF(ZN)2Y page 76 A-DF(ZN)2Y4Y page 78 A-DF(ZN)2Y(SR)2Y page 80 A-DQ(ZN)2Y(HD) ADSS 6kN page 82 A-D2Y(ZN)2Y ADSS 6kN page 84 A-DQ(ZN)2Y (HD) Minicable page 86 Fiber Data Sheet - Singlemodefiber E9 page 88 Fiber Data Sheet - Low Bend Sensitive Singlemodefiber E9 page 89 Fiber Data Sheet - NZDF-Singlemodefiber E8 page 90 Fiber Data Sheet - NZDF-Singlemodefiber E8 page 91 Fiber Data Sheet - Multimodefiber OM2 G50 page 92 Fiber Data Sheet - Multimodefiber OM3 (OM3+, OM4) G50 page 93 Fiber Data Sheet - Multimodefiber G62,5 page 94 Letter Symbols - Fiber Optics page 95 Colour Codes - Fiber Optics page 96 Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 75

76 Fiber Optical Outdoor Cables - Standard Design Outdoor Cable, filled, loose tube construction A-DF(ZN)2Y Typ number of tubes number of numbers of tube-diameter tensile strength weight outer diameter + fillers fibers / tube fibers approx. mm max. N approx. kg/km approx. mm A-DF(ZN)2Y (4) 2 (4) 2, ,5 A-DF(ZN)2Y (4) 4 (8) 2, ,5 A-DF(ZN)2Y (4) 6 (12) 2, ,5 A-DF(ZN)2Y (4) 8 (16) 2, ,5 A-DF(ZN)2Y (4) 10 (20) 2, ,5 A-DF(ZN)2Y (4) 12 (24) 2, ,5 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,7 A-DF(ZN)2Y , ,5 A-DF(ZN)2Y , ,3 A-DF(ZN)2Y , ,7 A-DF(ZN)2Y , ,7 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,7 A-DF(ZN)2Y , ,5 A-DF(ZN)2Y , ,3 A-DF(ZN)2Y , ,7 A-DF(ZN)2Y , ,7 76 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

77 Typ number of tubes number of numbers of tube-diameter tensile strength weight outer diameter + fillers fibers / tube fibers approx. mm max. N approx. kg/km approx. mm A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,5 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,5 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,5 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,3 A-DF(ZN)2Y , ,0 A-DF(ZN)2Y , ,5 A-DF(ZN)2Y , ,0 For telecommunication and information systems. FRP-central element loose tubes, SZ-cabling (if necessary with fillers) jelly filled cable core strength members (aramide yarns) PE-sheath, UV-resistant, black Fiber colours red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink Tube colours counter core red, others yellow (E9), green (G50) or blue (G62,5) Note longitudinally water-tight On request other number of tubes increased tensile strength reinforced outer sheath (2YV) other sheath colours coloured stripes HDPE or LDPE sheath other tube and fiber colours Laying usable for fixed laying in earth, ducts or conduits and outdoors double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing other markings on request Technical Data tensile strength according to IEC E1 according to EN value: Please have a look at the relevant chart. compressive strength according to IEC E3 (crush) according to EN value: 2500 N/10 cm impact according to IEC E4 according to EN value: 25 Nm torsion according to IEC E7 according to EN value: 5 cycles ±1 turn kink, cable according to IEC E10 according to EN value: The cables do not form a kink when a loop is drawn together to a diameter 12 times the cable nominal diameter. kink, loose tube according to IEC E16 according to EN value: The loose tubes do not kink. min. bending radius according to IEC E11 according to EN value: R = 20 x D (cable outer diameter) temperature range according to IEC F1 according to EN storage and transport: -40 C to +70 C laying: -5 C to +60 C operation: -30 C to +70 C water penetration according to IEC F5 according to EN No water on free end. Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 77

78 Fiber Optical Outdoor Cables - Standard Design Outdoor Cable, filled, loose tube construction, metal-free rodent protection A-DF(ZN)2Y4Y Typ number of tubes number of numbers of tube-diameter tensile strength weight outer diameter + fillers fibers / tube fibers approx. mm max. N approx. kg/km approx. mm A-DF(ZN)2Y4Y (4) 2 (4) 2, ,5 A-DF(ZN)2Y4Y (4) 4 (8) 2, ,5 A-DF(ZN)2Y4Y (4) 6 (12) 2, ,5 A-DF(ZN)2Y4Y (4) 8 (16) 2, ,5 A-DF(ZN)2Y4Y (4) 10 (20) 2, ,5 A-DF(ZN)2Y4Y (4) 12 (24) 2, ,5 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,7 A-DF(ZN)2Y4Y , ,5 A-DF(ZN)2Y4Y , ,3 A-DF(ZN)2Y4Y , ,7 A-DF(ZN)2Y4Y , ,7 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,7 A-DF(ZN)2Y4Y , ,5 A-DF(ZN)2Y4Y , ,3 A-DF(ZN)2Y4Y , ,7 A-DF(ZN)2Y4Y , ,7 78 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

79 Typ number of tubes number of numbers of tube-diameter tensile strength weight outer diameter + fillers fibers / tube fibers approx. mm max. N approx. kg/km approx. mm A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,5 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,5 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,5 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,4 A-DF(ZN)2Y4Y , ,0 A-DF(ZN)2Y4Y , ,5 A-DF(ZN)2Y4Y , ,0 For telecommunication and information systems. FRP-central element loose tubes, SZ-cabling (if necessary with fillers) filling of cable core strength members (aramide yarns) PE-sheath, UV-resistant, black PA-protective cover, UV-resistant, transparent Fiber colours red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink Tube colours counter core red, others yellow (E9), green (G50) or blue (G62,5) Note longitudinally water-tight On request other number of tubes increased tensile strength other sheath colours coloured stripes HDPE or LDPE sheath other tube and fiber colours Laying usable for fixed laying in earth, ducts or conduits and outdoors double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing other markings on request Technical Data tensile strength according to IEC E1 according to EN value: Please have a look at the relevant chart. compressive strength according to IEC E3 (crush) according to EN value: 3000 N/10 cm impact according to IEC E4 according to EN value: 25 Nm torsion according to IEC E7 according to EN value: 5 cycles ±1 turn kink, cable according to IEC E10 according to EN value: The cables do not form a kink when a loop is drawn together to a diameter 12 times the cable nominal diameter. kink, loose tube according to IEC E16 according to EN value: The loose tubes do not kink. min. bending radius according to IEC E11 according to EN value: R = 20 x D (cable outer diameter) temperature range according to IEC F1 according to EN storage and transport: -40 C to +70 C laying: -5 C to +60 C operation: -30 C to +70 C water penetration according to IEC F5 according to EN No water on free end. Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 79

80 Fiber Optical Outdoor Cables - Standard Design Outdoor Cable, filled, loose tube construction, metallic rodent protection A-DF(ZN)2Y(SR)2Y Typ number of tubes number of numbers of tube-diameter tensile strength weight outer diameter + fillers fibers / tube fibers approx. mm max. N approx. kg/km approx. mm A-DF(ZN)2Y(SR)2Y (4) 2 (4) 2, ,0 A-DF(ZN)2Y(SR)2Y (4) 4 (8) 2, ,0 A-DF(ZN)2Y(SR)2Y (4) 6 (12) 2, ,0 A-DF(ZN)2Y(SR)2Y (4) 8 (16) 2, ,0 A-DF(ZN)2Y(SR)2Y (4) 10 (20) 2, ,0 A-DF(ZN)2Y(SR)2Y (4) 12 (24) 2, ,0 A-DF(ZN)2Y(SR)2Y , ,5 A-DF(ZN)2Y(SR)2Y , ,5 A-DF(ZN)2Y(SR)2Y , ,5 A-DF(ZN)2Y(SR)2Y , ,5 A-DF(ZN)2Y(SR)2Y , ,5 A-DF(ZN)2Y(SR)2Y , ,5 A-DF(ZN)2Y(SR)2Y , ,5 A-DF(ZN)2Y(SR)2Y , ,5 A-DF(ZN)2Y(SR)2Y , ,5 A-DF(ZN)2Y(SR)2Y , ,5 A-DF(ZN)2Y(SR)2Y , ,5 A-DF(ZN)2Y(SR)2Y , ,5 A-DF(ZN)2Y(SR)2Y , ,5 A-DF(ZN)2Y(SR)2Y , ,5 A-DF(ZN)2Y(SR)2Y , ,5 A-DF(ZN)2Y(SR)2Y , ,5 A-DF(ZN)2Y(SR)2Y , ,5 A-DF(ZN)2Y(SR)2Y , ,5 A-DF(ZN)2Y(SR)2Y , ,0 A-DF(ZN)2Y(SR)2Y , ,0 A-DF(ZN)2Y(SR)2Y , ,7 80 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

81 Typ number of tubes number of numbers of tube-diameter tensile strength weight outer diameter + fillers fibers / tube fibers approx. mm max. N approx. kg/km approx. mm A-DF(ZN)2Y(SR)2Y , ,2 A-DF(ZN)2Y(SR)2Y , ,2 A-DF(ZN)2Y(SR)2Y , ,2 A-DF(ZN)2Y(SR)2Y , ,2 A-DF(ZN)2Y(SR)2Y , ,2 A-DF(ZN)2Y(SR)2Y , ,0 A-DF(ZN)2Y(SR)2Y , ,2 A-DF(ZN)2Y(SR)2Y , ,2 A-DF(ZN)2Y(SR)2Y , ,2 A-DF(ZN)2Y(SR)2Y , ,2 A-DF(ZN)2Y(SR)2Y , ,2 A-DF(ZN)2Y(SR)2Y , ,0 A-DF(ZN)2Y(SR)2Y , ,2 A-DF(ZN)2Y(SR)2Y , ,2 A-DF(ZN)2Y(SR)2Y , ,2 A-DF(ZN)2Y(SR)2Y , ,2 A-DF(ZN)2Y(SR)2Y , ,2 A-DF(ZN)2Y(SR)2Y , ,0 A-DF(ZN)2Y(SR)2Y , ,2 A-DF(ZN)2Y(SR)2Y , ,7 A-DF(ZN)2Y(SR)2Y , ,5 For telecommunication and information systems. FRP-central element loose tubes, SZ-cabling (if necessary with fillers) jelly filled cable core strength members (aramide yarns) PE-inner sheath corrugated steel tape, laminated PE-outer sheath, UV-resistant, black Fiber colours red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink Tube colours counter core red, others yellow (E9), green (G50) or blue (G62,5) Note longitudinally water-tight On request other number of fibers (max. 432) other number of tubes increased tensile strength reinforced outer sheath (2YV) other sheath colours coloured stripes HDPE or LDPE sheath other tube and fiber colours dry filled version Laying usable for fixed laying in earth, ducts or conduits and outdoors double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing other markings on request Technical Data tensile strength according to IEC E1 according to EN value: Please have a look at the relevant chart. compressive strength according to IEC E3 (crush) according to EN value: 3000 N/10 cm impact according to IEC E4 according to EN value: 25 Nm torsion according to IEC E7 according to EN value: 5 cycles ±1 turn kink, cable according to IEC E10 according to EN value: The cables do not form a kink when a loop is drawn together to a diameter 12 times the cable nominal diameter. kink, loose tube according to IEC E16 according to EN value: The loose tubes do not kink. min. bending radius according to IEC E11 according to EN value: R = 20 x D (cable outer diameter) temperature range according to IEC F1 according to EN storage and transport: -40 C to +70 C laying: -5 C to +60 C operation: -30 C to +70 C water penetration according to IEC F5 according to EN No water on free end. Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 81

82 All-Dielectric-Self-Supporting Cables (ADSS) Aerial Cable, single sheath, loose tube construction, metal-free A-DQ(ZN)2Y(HD)... 6kN Typ number of tubes number of numbers of tube-diameter tensile strength weight outer diameter + fillers fibers / tube fibers approx. mm max. N approx. kg/km approx. mm A-DQ(ZN)2Y (4) 2 (4) 2, ,0 A-DQ(ZN)2Y (4) 4 (8) 2, ,0 A-DQ(ZN)2Y (4) 6 (12) 2, ,0 A-DQ(ZN)2Y (4) 8 (16) 2, ,0 A-DQ(ZN)2Y (4) 10 (20) 2, ,0 A-DQ(ZN)2Y (4) 12 (24) 2, ,0 A-DQ(ZN)2Y , ,6 A-DQ(ZN)2Y , ,6 A-DQ(ZN)2Y , ,6 A-DQ(ZN)2Y , ,6 A-DQ(ZN)2Y , ,6 A-DQ(ZN)2Y , ,6 A-DQ(ZN)2Y , ,6 A-DQ(ZN)2Y , ,6 A-DQ(ZN)2Y , ,6 A-DQ(ZN)2Y , ,6 A-DQ(ZN)2Y , ,6 A-DQ(ZN)2Y , ,6 A-DQ(ZN)2Y , ,6 A-DQ(ZN)2Y , ,6 A-DQ(ZN)2Y , ,6 A-DQ(ZN)2Y , ,6 A-DQ(ZN)2Y , ,6 A-DQ(ZN)2Y , ,6 A-DQ(ZN)2Y , ,2 A-DQ(ZN)2Y , ,0 A-DQ(ZN)2Y , ,8 82 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

83 Metal-free aerial cable (ADSS = alldielectric selfsupporting) for telecommunication and information systems. FRP-central element loose tubes, SZ-cabling (if necessary with fillers) strength members (aramide yarns) HDPE-outer sheath, UV-resistant, black Fiber colours red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink Tube colours counter core red, others yellow (E9), green (G50) or blue (G62,5) Note not longitudinally water-tight On request other number of tubes for temperatures down to -60 C other tube and fiber colours Laying usable for fixed laying on selfsupporting lines (up to 60kV) and overhead contact lines, in earth, ducts or conduits and outdoors double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing other markings on request Technical Data tensile strength according to IEC E1 according to EN compressive strength according to IEC E3 (crush) according to EN value: 3000 N/10 cm impact according to IEC E4 according to EN value: 25 Nm torsion according to IEC E7 according to EN value: 5 cycles ±1 turn kink, cable according to IEC E10 according to EN value: The cables do not form a kink when a loop is drawn together to a diameter 12 times the cable nominal diameter. kink, loose tube according to IEC E16 according to EN value: The loose tubes do not kink. temperature range according to IEC F1 according to EN storage and transport: -40 C to +70 C laying: -5 C to +60 C operation: -30 C to +70 C water penetration according to IEC F5 according to EN value: No water on free end. span distance up to 100 m Span distance calculation on request: We need the following parameter values: horinzontal distance from pole to pole:? [m] height difference from pole to pole:? [m] sag in meters or percent to the above mentioned values:? [m-%] ballast or added weight (ice and wind):? [kg/m] Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 83

84 All-Dielectric-Self-Supporting Cables (ADSS) Aerial Cable, unfilled, loose tube construction, metal-free A-D2Y(ZN)2Y... 6kN Typ number of tubes number of numbers of tube-diameter tensile strength weight outer diameter + fillers fibers / tube fibers approx. mm max. N approx. kg/km approx. mm A-D2Y(ZN)2Y (4) 2 (4) 2, ,0 A-D2Y(ZN)2Y (4) 4 (8) 2, ,0 A-D2Y(ZN)2Y (4) 6 (12) 2, ,0 A-D2Y(ZN)2Y (4) 8 (16) 2, ,0 A-D2Y(ZN)2Y (4) 10 (20) 2, ,0 A-D2Y(ZN)2Y (4) 12 (24) 2, ,0 A-D2Y(ZN)2Y , ,1 A-D2Y(ZN)2Y , ,1 A-D2Y(ZN)2Y , ,1 A-D2Y(ZN)2Y , ,1 A-D2Y(ZN)2Y , ,1 A-D2Y(ZN)2Y , ,6 A-D2Y(ZN)2Y , ,1 A-D2Y(ZN)2Y , ,1 A-D2Y(ZN)2Y , ,1 A-D2Y(ZN)2Y , ,1 A-D2Y(ZN)2Y , ,1 A-D2Y(ZN)2Y , ,6 A-D2Y(ZN)2Y , ,1 A-D2Y(ZN)2Y , ,1 A-D2Y(ZN)2Y , ,1 A-D2Y(ZN)2Y , ,1 A-D2Y(ZN)2Y , ,1 A-D2Y(ZN)2Y , ,6 A-D2Y(ZN)2Y , ,2 A-D2Y(ZN)2Y , ,1 A-D2Y(ZN)2Y , ,0 84 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

85 Metal-free aerial cable (ADSS = alldielectric selfsupporting) for telecommunication and information systems. FRP-central element loose tubes, SZ-cabling (if necessary with fillers) dry filled cable core strength members (aramide yarns) HDPE-outer sheath, UV-resistant, black Fiber colours red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink Tube colours counter core red, others yellow (E9), green (G50) or blue (G62,5) Note not longitudinally water-tight On request other number of tubes for temperatures down to -60 C other tube and fiber colours Laying usable for fixed laying on selfsupporting lines (up to 60kV) and overhead contact lines, in earth, ducts or conduits and outdoors double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing other markings on request Technical Data tensile strength according to IEC E1 according to EN compressive strength according to IEC E3 (crush) according to EN value: 3000 N/10 cm impact according to IEC E4 according to EN value: 25 Nm torsion according to IEC E7 according to EN value: 5 cycles ±1 turn kink, cable according to IEC E10 according to EN value: The cables do not form a kink when a loop is drawn together to a diameter 12 times the cable nominal diameter. kink, loose tube according to IEC E16 according to EN value: The loose tubes do not kink. temperature range according to IEC F1 according to EN storage and transport: -40 C to +70 C laying: -5 C to +60 C operation: -30 C to +70 C water penetration according to IEC F5 according to EN value: No water on free end. span distance up to 100 m Span distance calculation on request: We need the following parameter values: horinzontal distance from pole to pole:? [m] height difference from pole to pole:? [m] sag in meters or percent to the above mentioned values:? [m-%] ballast or added weight (ice and wind):? [kg/m] Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 85

86 Stranded loose tube Mini cable with optical fibers Mini Cable, dry filled, loose tube construction, metal-free A-DQ(ZN)2Y (HD) Type number number of tubes tube- tensile strength outer-diameter weight of fibers (fillers) approx. mm max. N approx. mm approx. kg/km A-DQ(ZN)2Y (HD) 1x4 4 1 (5) 1, A-DQ(ZN)2Y (HD) 1x8 8 1 (5) 1, A-DQ(ZN)2Y (HD) 1x (5) 1, A-DQ(ZN)2Y (HD) 2x (4) 1, A-DQ(ZN)2Y (HD) 3x (3) 1, A-DQ(ZN)2Y (HD) 4x (2) 1, A-DQ(ZN)2Y (HD) 5x (1) 1, A-DQ(ZN)2Y (HD) 6x (0) 1, A-DQ(ZN)2Y (HD) 8x (0) 1, A-DQ(ZN)2Y (HD) 12x (0) 1, A-DQ(ZN)2Y (HD) 1x4 4 1 (5) 1, A-DQ(ZN)2Y (HD) 1x8 8 1 (5) 1, A-DQ(ZN)2Y (HD) 1x (5) 1, A-DQ(ZN)2Y (HD) 2x (4) 1, A-DQ(ZN)2Y (HD) 3x (3) 1, A-DQ(ZN)2Y (HD) 4x (2) 1, A-DQ(ZN)2Y (HD) 5x (1) 1, A-DQ(ZN)2Y (HD) 6x (0) 1, A-DQ(ZN)2Y (HD) 8x (0) 1, A-DQ(ZN)2Y (HD) 12x (0) 1, A-DQ(ZN)2Y (HD) 6x (0) 2, Suitable for Metro, Access or FTTx implementations rip cord central member, metal free loose buffer tube filled with a thixotropic gel, swellable aramid yarns dry filled cable core HDPE-sheath, UV-resistant, black Fiber colours blue, orange, green, brown, slate, white, red, black, yellow, violet, pink, turquoise Tube colours up to 12 tubes: blue, orange, green, brown, slate, white, red, black, yellow, violet, pink, turquoise Technical Data Temp. range storage and transport -30 C up to +60 C laying -5 C up to +50 C operation -30 C up to +60 C Crush resistance 900 N/10 cm Impact strength 5 Nm (3 impacts, 300 mm hammer radius) Water penetration 1 m (0.1 bar, 24 h) Bending radius permanent 65 mm during installation 90 mm Filling element colour natural On request other sheath colours other tube and fiber colours Laying for installation in miniduct systems double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing other markings on request 86 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

87 Fiber Optic Cables Note Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 87

88 Fiber Data Sheet Singlemodefiber (SM) E9 Common fiber type E9/125 Singlemode Fiber standard ITU-T G.652 D; EN188000, EN , EN ; VDE 0888/part 102, VDE 0888/part 103, TS 0311/part 3 and TS 0311/part 2 of DTAG fiber decribtion The fiber is ideally designed for use in metropolitan, local and access networks due to its superior specifications - low optical loss aross the entire wavelength range from 1260 to 1625 nm, tightest available geometry, low splice loss and low polarization mode dispersion. Mechanical Properties core diameter d at 1310 nm 9.2 ±0.4 µm at 1550 nm 10.4 ±0.5 µm core concentricity error 0.5 µm cladding diameter 125 ±0.7 µm cladding non-circularity 0.7 % cladding/coating concentricity error 12.0 µm coating non-circularity 6.0 % fiber diameter uncoloured 242 ±5 µm coloured 250 ±10 µm tensile strength according to EN PV201, 1s 8 N strain level 120 kpsi coating strip force 3.5 N bending radius 30 mm Optical Properties max / typical attenuation at 1310 nm 0.34 / 0.32 db/km at 1383 nm 0.31 / 0.28 db/km at 1490 nm 0.23 / 0.21 db/km at 1550 nm 0.21 / 0.19 db/km at 1625 nm 0.23 / 0.20 db/km attenuation inequality (...) at 1310 and 1550 nm 0.05 db/km attenuation (Makrobending) at 1310 and 1550 nm 0.05 db attenuation alteration (range -60 up to +85 C) at 1310 and 1550 nm 0.05 db/km attenuation for WDM/EÜS at 1550 ±20 nm 0.22 db/km chromatic dispersion at nm 3 ps/(nm*km) at nm 12 ps/(nm*km) at nm 19 ps/(nm*km) polarization mode dipersion (PMD) 0.1 ps/ km PMD Link Design Value acc. IEC 60794/5.5 Method ps/ km fiber cut-off wavelength (referred to RTM) λ cf -range nm cable cut-off wavelength λ cff -range 1260 nm point defect at pulse-width 10ns at 1310 and 1550 nm 0.05 db zero dispersion wavelength λ nm zero dispersion slope s ps/(nm²*km) refraction index at 1310 nm at 1550 nm Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

89 Fiber Data Sheet Singlemodefiber (SM) - Low Bend Sensitive E9 Common fiber type standard fiber describtion E9/125 Singlemode Fiber with higher Bend Performance ITU-T G.657 A1, A2/B2; IEC type B.1.3 The macrobending and microbending loss improvements of this low bend sensitive fiber offer a number of advantages for demanding access, enterprise and central office applications. The fiber enables more compact cabinet and enclosure designs and protects the network against excessive loss resulting from inadvertent fiber bends. It is less susceptible to physical disturbancees from cable flexing, pulling and crushing, as well as the intricate routing conditions within enclosures and cabinets. The optimized bend characteristics of this fiber also help improve cable performance in demanding high-stress and low-temperature environments by providing double the microbend protection of conventional singl-mode fibers. Mechanical Properties A1 A2/B2 core diameter d at 1310 nm µm at 1550 nm µm coreconcentricity error µm cladding diameter 125 ± ±0.7 µm cladding non-circularity % cladding/coating concentricity error µm coating non-circularity % fiber diameter uncoloured µm coloured max. 265 max. 265 µm tensile strength according to EN PV201, 1s 8 8 N strain level kpsi coating strip force N bending radius mm Optical Properties max. / typical max. / typical attenuation at 1310 nm 0.35 / / 0.34 db/km at 1383 nm 0.31 / / 0.28 db/km at 1490 nm 0.24 / / 0.21 db/km at 1550 nm 0.21 / / 0.19 db/km at 1625 nm 0.24 / / 0.20 db/km refraction index at 1310 nm at 1550 nm attenuation inequality (...) at 1310 and 1550 nm db/km attenuation alteration (range -60 up to +85 C) at 1310 und 1550 nm db/km chromatic dispersion at nm ps/(nm*km) at 1550 nm ps/(nm*km) polarization mode dipersion (PMD) ps/ km fiber cut-off wavelength (referred to RTM) λ cf -range nm cable cut-off wavelength λ cff -range nm point defect at pulse-width 10ns at 1310 and 1550 nm db zero dispersion wavelength λ nm zero dispersion slope s ps/(nm²*km) Macrobend Performances 100 turns on a 25mm radius mandrel at 1550 nm db at 1625 nm db 10 turns on a 15mm radius mandrel at 1550 nm db at 1625 nm db 1 turns on a 10mm radius mandrel at 1550 nm db at 1625 nm db 1 turns on a 7.5mm radius mandrel at 1550 nm db at 1625 nm db Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 89

90 Fiber Data Sheet NZDF-Singlemodefiber (NZDF) E8 Common fiber type standard fiber describtion Non-Zero-Dispersion-Shifted Singlemode Fiber ITU-T G.655, ITU-T G.656; EN188000, EN , EN core consists of SiO 2 doped with GeO 2 ; optical cladding of quarzglass (SiO 2 ); step profile of the refraction index, matched cladding, phosphorus free; protective coating consisting of two layers of UV-cured acrylate resins Mechanical Characteristics G.656 G.655.d G.656 G.656 G.655.d (G.655.c, e) (G.655.c) (G.655.e) (G.655.e) True-Wave True-Wave Tera Light TM Tera Light TM Leaf Reach RS MetroFiber UltraFiber core diameter d at 1550 nm 8.6 ± ± ± ±0,5 9.6 ±0.4 µm at 1600 nm ± µm cladding diameter 125 ± ± ±1 125 ±1 125 ±0.7 µm core/cladding excentricity µm cladding non-circularity % cladding/coating excentricity µm coating non-circularity % fiber diameter uncoloured 242 ±5 242 ±5 242 ±7 242 ±7 245 ±5 µm coloured µm tensile strength according to N EN PV201, 1s strain level kpsi stripping force N bending radius mm Optical Characteristics attenuation at 1550 nm db/km at 1625 nm db/km attenuation (water peak) at 1383 ±3 nm db/km attenuation (macrobending) 1 turn, 32mm at 1550 nm db at 1625 nm db 100 turns, 75mm 1) at 1550 nm db at 1625 nm db attenuation alteration db/km (range -60 up to +85 C) no point discontinuity at 1550 nm db chromatic dispersion at nm ps/(nm*km) at nm ps/(nm*km) polarisation mode- link design value ps/ km dispersion (PMD) max. individual fiber ps/ km point defect at 1550 nm db refraction index at 1550 nm ) at TeraLight TM Fibers: 60 mm 90 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

91 Fiber Data Sheet NZDF-Singlemodefiber (NZDF) E8 Common fiber type standard fiber describition Non-Zero-Dispersion-Shifted Singlemode Fiber ITU-T G.655, ITU-T G.656; EN188000, EN , EN PENGG KABEL offers non-zero dispersion shifted single mode optical fibers produced by the Vapour Phase Axial Deposition (VAD) method, which enables construction of high-capacy, ultra long haul WDM systems. This fibers allows the easier deployment of WDM in metropolitan areas, and increases the capacity of fiber in WDM systems throughout the wavelength region between 1460 nm and 1625 nm (S, C, L-bands, 1460 nm only for G.656 fiber). It s non-zero dispersion caracteristic reduces four-wave mixing and cross-phase modulation over a wider wavelength range than conventional NZDF. Our NZDF fibers has the ability to increase transmission speeds of systems up to 10 Gb/s and 40 Gb/s and also has superior polarization mode dispersion performance. Compostion core cladding coating Germanium doped silica Silica Dual layers of UV-cured acrylate Geometrical Characteristics G.656 G.655.a (G.655.c, e) (G.655.d) core diameter d at 1550 nm 9.0 ± ±0.4 µm cladding diameter ± ±0.7 µm core/cladding concentricity error µm cladding non-circularity % fiber curl radius 4 4 m primary coating diameter 242 ±5 245 ±5 µm coating/cladding concentricity error µm Optical Characteristics attenuation at 1460 nm (only G.656) db/km at 1550 nm db/km at 1625 nm db/km point discontinuity at 1550 nm db chromatic dispersion at 1460 to 1625 nm (only G.656) 2.0 bis ps/(nm*km) at 1530 to 1565 nm 5.5 bis bis 6.0 ps/(nm*km) at 1565 to 1625 nm 7.5 bis bis 11.2 ps/(nm*km) cut-off wavelength of cabled fiber nm PMD individual fiber ps/ km link design value (typical) ps/ km Mechanical Characteristics fiber proof test level kpsi (1.2% strain) macrobending loss for 100 turns at a 75 or 60 mm mandrel diameter at 1550 (and 1625 nm at G.655.a) db 1 turn at a 32 mm mandrel diameter at 1550 (and 1625 nm at G.655.a) db coating strip force 1.3 bis bis 8.9 N dynamic fatigue resistance parameter Enviromental Characteristics induced attenuation at 1310 nm and 1550 nm from -60 C to +85 C temperature cycling db/km 85 C / 98% RH temperature humidity cycling db/km +85 C heating aging db/km +23 C water immersion db/km Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 91

92 Fiber Data Sheet Multimodefiber (MM) OM 2 - Quality G50 Common fiber type standard fiber describtion G50/125 according to VDE (Typ A1a), G50/125 according ÖVE or TA ITU-T G.651; EN188000, EN , EN ; VDE0888/part 105, VDE0888/part 106, FZA TS0053/01 core consists of SiO 2 doped with GeO 2 ; optical cladding of quarzglass (SiO 2 ); graded profile of the refraction index, matched cladding, phosphorus free; protective coating consisting of two layers of UV-cured acrylate resins Mechanical Properties core diameter d 50 ±2.5 µm core non-circularity 5.0 % core/cladding concentricity error 1.5 µm cladding diameter 125 ±2 µm cladding non-circularity 1.0 % cladding/coating concentricity error 10.0 µm coating non-circularity 6.0 % fiber diameter uncoloured 245 ±10 µm coloured 265 µm tensile strength according to EN PV201, 1s 8 N strain level 100 kpsi stripping force 3.5 N bending radius 30 mm Optical Properties attenuation at 850nm 2.5 db/km at 1300 nm 0.6 db/km at 1383 nm 2.0 db/km band width at 850 nm MHz*km (others on request) at 1300 nm MHz*km (others on request) attenuation (makrobending) 0.5 db attenuation alteration (range -60 up to +85 C) 0.2 db/km numeric aperture at 850 nm 0.2 ±0.015 refraction index at 850 nm at 1300 nm link lengths at 1 Gb/s at 850 nm m at 1300 nm m 92 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

93 Fiber Data Sheet Multimodefiber (MM) OM 3 - Quality (OM 3+, OM 4) G50 Common fiber type standard fiber describition G50/125 according to VDE (Typ A1a), G50/125 according ÖVE or TA ITU-T G.651; EN188000, EN , EN ; VDE0888/part 105, VDE0888/part 106, FZA TS0053/01 core consists of SiO 2 doped with GeO 2 ; optical cladding of quarzglass (SiO 2 ); graded profile of the refraction index, matched cladding, phosphorus free; protective coating consisting of two layers of UV-cured acrylate resins Mechanical Properties core diameter d 50 ±2.5 µm core non-circularity 5.0 % core/cladding concentricity error 1.5 µm cladding diameter 125 ±1 µm cladding non-circularity 1.0 % cladding/coating concentricity error 10.0 µm coating non-circularity 6.0 % fiber diameter uncoloured 245 ±10 µm coloured 265 µm tensile strength according to EN PV201, 1s 8 N strain level 100 kpsi stripping force 3.5 N bending radius 30 mm Optical Properties attenuation at 850nm 2.5 db/km at 1300 nm 0.7 db/km at 1383 nm 2.0 db/km refraction index at 850 nm at 1300 nm attenuation (makrobending) 0.5 db attenuation alteration (range -60 up to +85 C) 0.2 db/km numeric aperture at 850 nm 0.2 ±0.015 Performance Characteristics OptiGrade Classes Bandwith 850 nm MHz*km (Overfilled Launch, LED based sources) 1300 nm MHz*km Effective Modal Bandwith 850 nm MHz*km Assured by: Differential Mode Delay (DMD) Fibers shall meet the respective DMD templates specified in or according to the standard TIA/EIA or IEC , for transmitters meeting TIA/EIA-492 AAAC. Each template includes an inner and an outer mask requirement with: Inner mask: Outer mask: R inner = 5 µm to R outer = 18 µm R inner = 0 µm to R outer = 23 µm Upon request our fiber can be selected meeting inner mask radial specifications more stringent tha n the TIA/EIA-492 AAAC requirement: Inner mask: R inner = 0 µm to R outer = 18 µm Further to meeting the respective DMD template all OptiGrade fiber meets the additional requirement of IEC in the radial offset intervall masks, which sources out fibers, having rapid changes of the DMD. Transmission link lenghts 850 nm m for 10 Gb/s* 1300 nm (LX4) m *at 850 nm operating radius 4.5 µm 30 % wavelenth with transmitters radius 19.0 µm 86 % meeting encircled flux at Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 93

94 Fiber Data Sheet Multimodefiber (MM) G62,5 Common fiber type standard fiber describition G62,5/125 according to VDE (Typ A1b),, G62,5/125 according ÖVE or TA EN188000, EN , EN ; VDE0888/part 105, VDE0888/part 107, FZA TS0053/01 core consists of SiO 2 doped with GeO 2 ; optical cladding of quarzglass (SiO 2 ); graded profile of the refraction index, matched cladding, phosphorus free; protective coating consisting of two layers of UV-cured acrylate resins Mechanical Properties core diameter d 62.5 ±2.5 µm core non-circularity 5.0 % cladding diameter 125 ±2 µm core/cladding concentricity error 1.5 µm cladding non-circularity 1.0 % cladding/coating excentricity 10.0 µm coating non-circularity 6.0 % fiber diameter uncoloured 245 ±10 µm coloured 265 µm tensile strength according to EN PV201, 1s 8 N strain level 100 kpsi stripping force 3.5 N bending radius 30 mm Optical Properties attenuation at 850nm 3.0 db/km at 1300 nm 1.0 db/km at 1383 nm 2.0 db/km band width at 850 nm MHz*km (Standard 200) at 1300 nm MHz*km (Standard 600) attenuation (makrobending) 0.05 db attenuation alteration (range -60 up to +85 C) 0.2 db/km numeric aperture at 850 nm ±0.015 db refraction index at 850 nm at 1300 nm link lengths at 1 Gb/s at 850 nm m at 1300 nm m 94 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

95 Letter Symbols - Fiber Optics Letter symbols according to VDE (outdoor cables) Letter symbols according to VDE (indoor cables) Fiber Optic Cables Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 95

96 Colour Codes - Fiber Optics Colour Code - Fibers (Standard, others on request) Pengg Standard Fiber Colouring: Ring Signing: Colour Code - Tubes (Standard) 5-tubes construction 1 x n 2 x n 3 x n 4 x n 5 x n Singlemode Fibers NZDF-Fibers E8 Multimode Fibers G50 Multimode Fibers G62,5 no fiber assignment 6-tubes construction 1 x n 2 x n 3 x n 4 x n 5 x n 6 x n Singlemode Fibers E9 NZDF-Fibers E8 Multimode Fibers G50 Multimode Fibers G62,5 no fiber assignment 96 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

97 General Information Types page 98 Letter symbols page 99 Examples for telecommunication cables page 99 Basic formulas for telecommunication technique page 100 Units page 100 Basic formulas for homogeneous, symmetrical cables page 100 Shifting guideline page 102 Bending radius page 102 Installation temperature page 102 Tensile load for control and telecommunication cables page 102 Tensile load for telecommunication cables with guaranteeing tensile strength resistance page 103 Common explanations page 104 Pictograms Copper Cables page 104 Pictograms Fiber Optic Cables page 105 Characteristic features of insulation and sheath material page 105 RAL-colour code page 106 Behaviour in case of fire, fire away line, fire load page 107 Nominal data of wooden drums page 109 Drums according to DIN (dimensions, weights) page 109 Capacity (spooling length) page 110 Terms of delivery page 113 General Information Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 97

98 Types Signalling- and measuring cables Signal and measuring cables are used for transmission of DC- and low frequency AC-signals in telemetering-, signal-, clock- and paging systems as well as for control system (railway signals, signal boxes) and for supervision systems. The cables consist of PE-insulated cores, which are stranded together in concentric layers. The non-armoured types have a PVC-sheath over the cable core, the armoured types have a PVC-sheath (PE-sheath according to ÖVE), a steel tape armouring and a PVC-outer protective cover. Switchboard cables Switchboard cables are used as connection between racks, main distributors and switch stations in different kinds of railway offices (central offices, amplification bases and signal boxes). The cores are PVC-insulated. Cores are stranded together in layers; shielded pairs, triples, quads or quintuples are stranded together in layers or units. The shielded types have a screening of aluminium laminated PET-foil (static shield) over the cable core, the switchboard cables have a PVC-sheath. Local outdoor telecommunication cables They are used in local telecom networks, for the connection of telephone sets to telephone exchanges and as connection cables in industrial fields and in offices. The cables have quads of PE-, foam-pe- or foam-skin-pe insulated cores; the quads are stranded to unitss, the units are stranded to the cable core. The composite-layer sheath have a double-coated aluminium foil bonded with the PE-sheath. Petrol jelly fillings or swellable materials prevents water penetration along the cable. For special applications or customer-specifications the cables get additionally components, for example: PE-sheath, reinforced steel tape or steel wire armouring PE or PVC protective cover aluminium laminated PET-foil instead of aluminium tape Telecommunication switchboard wires They are used for switching and wiring of telecommunication instruments and similar ones, i.e. telephone exchanges, amplification bases and selection amplifiers. They consist of one or more twisted cores with PVC-insulation. Shielded switchboard strands They are used for switching of telecommunication instruments and similar ones, e.g. telephone exchanges, amplification bases and selection amplifiers. Shielded switchboard strands consists of one or more twisted, PVCinsulated cores, a copper braid screening and a PVC-sheath. Selfsupporting aerial cables Selfsupporting aerial carrier cables, so called SETRA cables, are used within the telecommunication network of the PTTs as well as in the domain of private telecom and data transmission networks. They have PE-insulated quads cabled to units and if necessary a shielding of aluminium foil; cable core and a supporting rope of galvanized steel wires with common PE-sheath (e.g. PVC-sheath). Also available with quads stranded in layers. Telecommunication installation wires Telecommunication installation wires are used for switching of telecom instruments in dry and eventually dump areas. They consists of one or more twisted PVC-insulated cores. Installation cables They are mainly needed for construction of telephone sets and extensions and suited for fixed laying on dry and wet ground material indoor and outdoor. The PVC-insulated pairs or quads are stranded together in layers or units. Depending on the type the cables are unshielded or shielded with an aluminium foil (static shield) and surrounded with a PVCsheath. Special cables for telecommunication Telecom cables for very specified applications and different special constructions (i.e. power protection cables, lightning protected telecommunication cables,railway signalling cables with inductive protection,...) belong to this field. Cables for industrial electronics These cables are used for transmission of signals and measuring values in units of the measuring, control and power electronic techniques as well as for data processing. They are composed of PVC-insulated cores or pairs stranded together into units. The shielded types have a screening of aluminium foil or copper braid. The cables for industrial electronics have a PVCsheath. Control cables Control cables are used for transmission of analogue and digital signals. Special constructions have proven to work under difficult transfer conditions and extreme severe environmental influences. Main applications: industrial process control, refineries, fuel dumps, chemical industry, power plants, as well as in sciences and research work. 98 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

99 Letter symbols - copper cables Letter symbol Description A- outdoor cable (GE) A aluminium shield (AT) AB outdoor cable with high voltage protection (GE) AD- outdoor cable for power line protection (e.g. Differentialschutz) (GE) AJ- outdoor cable with inductive protection (GE) AL aluminium shield (DK) AL+PE aluminium-pe laminated sheath (DK) B armouring (AT/GE) BD cables with units (GE) (1B...) one layer steel tape;...mm thickness of steel tape (GE) C protective cover of tarred jute (GE) C shield (copper braid) (GE) C shield (copper tape) (AT) CU copper conductor (DK) D shield with stranded copper wires (GE) DM Dieselhorst-Martin quad (GE) E drain wire (AT) F filling of cable core (GE) F quad with phantom utilization (GE) F installation cable, flat design (GE) F flat wire armouring (AT) F- telecomunication outdoor cable (AT) FI- telecommunication indoor cable (AT) FOL foil (DK) (FA) longitudinally aluminiumtape (GE) (F...) flat wire; thickness in...mm (GE) G conter helix (AT) G- mine cable (GE) H skin (in foam-skin insulations) (AT) (H...) peak value of mutual capacitance [nf/km] (GE) J cable core jelly filled (AT) J- installations cable (GE) JE- installations cable for industrial electronics (GE)...IMF element with metallic foil and drain wire (AT/GE) -K additionally corrosion proofing over armouring (GE) (K) innersheath and shield of londgitudinally copper tape (GE) Kx coax pair (AT/GE) KF design with resistance to cold (GE) L smooth aluminium tape (GE) (L) laminated aluminium tape (GE) (L)2Y composite layer sheath (GE) L- sheathed flexible cable (GE) LD corrugated aluminium sheath (GE) Letter Description symbol LG cabling in layers (GE) LI stranded or bunched conductor (GE) M lead sheath (AT/GE) MZ lead sheath with addition of setting (GE) 2M lead sheath with addition of setting (AT) (M...) max. mean value of mutual capacitance [nf/km] (GE) OF filling of cable core with special material (GE) P paper insulation (AT/GE) P pair (GE) PAP paper (wrapping) (DK) PE polyethylene (outer) sheath (DK) perf perforated (GE) Q steel wire braid (AT/GE) (R...) round wire; diameter in... mm (GE) R round wire armouring (AT) S railway signalling cable (GE) S- switchboard cable (GE) S- railway signalling cable (AT) SMPE foam-skin-pe insulation (DK) SPE foam-pe insulation (DK) ST quad in cables for long distances and phantom utilisation (GE) ST I quad in cables for long distances (GE) ST III quad in local telecommuncation cables (GE) (S...) set value of mutual capacitance [nf/km] (GE) (ST) static shield of metallic tape or aluminium laminated pet-foil (GE) T suspension wire (AT/GE) TF carrier frequency quad (GE) TF swelling material (GE) V tinned copper wire (AT) VAS filling of cable core (DK) vzn tinned (GE) W corrugated steel sheath (GE) Y PVC insulation, sheath or protective cover PVC (AT/GE) YV PVC sheath or protective cover, reinforced (GE) Y3V PVC sheath or protective cover, reinforced (AT) (Z) steel- or PA-braid, rssistant to extension (GE) (ZG) glass yarn strength members (GE) 2Y PE isulation, sheath or protective cover (AT/GE) 2YV PE sheath or protective cover, reinforced (GE) 2Y3V PE sheath or protective cover, reinforced (AT) 02Y foam-pe insulation (AT/GE) 02YH foam-skin-pe insulation (AT) 02YS foam-skin-pe insulation (GE) Examples for telecommunication cables A-02YSF(L)2Y 200x2x0.8 ST III BD Longitudinally waterproof local telecommunication cable with 100 foam-skin PE insulated quads, bare copper conductor, diameter 0.8 mm, stranded to units, jelly filled, paper tape covering and composite layer sheath; (similar to FTZ). J-Y(ST)Y 20x2x0.6 LG Installation cablel with 20 PVC-insulated pairs, bare copper conductor, diameter 0,6 mm, stranded in layers, plastic tape wrapping, static shield PETP aluminium foil with drain wire and PVC-sheath; (according to VDE 0815). A-2YYBY 16x1x0.9 S LG Railway signal cable with 16 PE insulated cores, stranded in layers, bare copper conductor, diameter 0.9 mm, plastic tape wrapping, PVCsheath, stell tape armouring and PVC protective cover (according to VDE 0816/part 2). General Information Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 99

100 Basic Formulas of Telecommunication Technique Units Term Symbol Letter symbol Unit angular frequency ω s -1 1/second attenuation (equivalent) a, α db (Np) dezibel (neper) attenuation coefficient α db/km (Np/km) dezibel (neper)/km capacitance load per unit length C F/km farad/km capacitance unbalance k, / k 1 / k 2,3 /k 9-12 / e 1,2 pf pikofarad conductivity κ Sm/mm² siemensmeter/mm² conductance G ms/km millisiemens/km conductance per unit length G S/km siemens/km conductor cross section q mm² millimeter² conductor resistance R Ω/km ohm/km current, strength of current I A ampere dissipation factor tan δ - - frequency f Hz hertz group delay τ g s/km second/km inductivity L mh/km millihenry/km inductivity load per unit length L H/km henry/km insulation resistance R is MΩkm megaohmkilometer image phase change coefficient β rad/km rad/km impedance (amount) Z Ω ohm impedance (complex) Z L Ω ohm impedance (imaginary part) Z i Ω ohm impedance (real part) Z r Ω ohm line length l km kilometer level p db (Np) dezibel (neper) magnetic unbalance m nh nanohenry mutual capacitance C nf/km nanofarad/km mutual inductance M mh/km millihenry/km near end cross talk attenuation (equivalent) a n, α n db (Np) dezibel (neper) phase delay τ p s/km second/km power P W watt reduction factor r k - - reflection coefficient r - - relative permittivity ε r - - resistance load per unit length R Ω/km ohm/km specific resistance s Ωmm²/m ohm mm²/m temperature t C degree celsius velocity of propagation v ü bit/s bit/second voltage U V volt wave length λ m meter Basic formulas for homogeneous, symmetrical cables Conductor resistance R t resistance at t C in Ohm R 20 resistance at 20 C in Ohm t temperature in C k for Cu or for Al Complex characteristic impedance Angular frequency Dissipation factor (Ω) 100 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

101 Basic Formulas of Telecommunication Technique Basic formulas for homogeneous, symmetrical cables Impedance (amount) at low frequencies (voice frequency) Impedance (amount) at high frequencies (ω L>R) (Ω) (Ω) L C inductivity (H/km) mutual capacitance (F/km) Attenuation at low frequencies (voice frequency) Attenuation at high frequencies (w L>R) (Np/km) (Np/km) (db/km) R G loop resistance (Ω/km) conductance (S/km) General Information Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 101

102 Shifting Guideline Bending radius When laying and bending the cables as well as at the mounting points (e.g. brackets) the bending radius R may not come up to those below stated. When forming out the cables during the assembly of appropriate treatment the minimum bending radius may be reduced at the most to half of the indicated values. Cable typ installation cables, switchboard cables Bending radius R minimum value 7.5 x D A outdoor cables with composite layer sheath outdoor cables 7.5 x D A 10 x D A D A... cable outer diameter Installation temperature For the transfer not the ambient temperature but the temperature of the cable is determining. With low ambient temperatures cables can be warmed up before shifting by suitable measures in such a way that the cable inside is not cooling under the permissible shifting temperature during the entire shifting procedure. Stress and jerks as well as stress by impact are to be avoided at low temperatures. The pulling speed of the cables should be as even as possible. temperature range during installation: cables with Polyethylene sheath (PE) -20ºC up to +50ºC cables with Polyvinylchlorid sheath (PVC) -5ºC up to + 50ºC Tensile load for control- and telecommunication cables (according to VDE 0891/part 6) The tensile stress indicated in the following tables applies uniformly to all for with guaranteeing tensile strength armouring cable, with which is included the cable core frictional connected with the cable sheath - either over a tie rod with pulling eye or a firmly mounting pulling trunk. Number of Maximum allowed value of tensile load [N] cores Conductor diam Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

103 Shifting Guideline Tensile strength of telecommunication outdoor cables with guaranteeing tensile strength resistance Number of double cores Maximum allowed value of tensile load [N] Conductor diam The values in the tables above refer to unarmoured cables with no guaranteeing tensile strength armouring. If higher traction loads are necessary, cables with a a garanteeing tensile strength armouring (steel round or rectangular wire) are to be planned. For the calculation of the tensile load for such cables applies an approximate value of 12 dan for each mm 2 steel cross section. General Information Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 103

104 Common Explanations Pictograms Copper Cables All datasheets are signed with common pictograms, which describe the cable make up and will lighten the localisation of the most applicable cable type. Mutual capacitance C35 C38 C42 C50 C52 C55 C60 Dimension of copper conductor conductor diameter [mm] 0,4 0,5 0,6 0,8 0,9 1,0 1,2 1,4 1,8 cross section [mm 2 ] Cable elements core pair triple quad quintuple pair in metal foil PIMF Number of double cores (DC) DC, talking circuit DC 4 DC 2-4 DC 4-8 DC n Filling unfilled petrol jelly Füllnidz dry filling / swellable materials Overall screening, armouring unshielded foil copper braid or tape foil and copper braid copper wires composite layer (L) armouring (steel tape, round steel wires) 104 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

105 Common Explanations Pictograms Fiber Optic Cables metal-free halogenfree, flame retardant rodent protection longitudinally water-tight indoor cable outdoor cable aerial cable (ADSS) Characteristic features of insulation and sheath materials Material Resistance to Spec. volume Continous possible break-down resistance operating temperature [kv/mm] [Ωcm] dauernd [ C] PVC (standard compound) up to +70 PVC (compound for telephon cores) up to +70 LDPE up to +70 HDPE up to +90 Foam-PE up to +70 Material Operating temperatur Decomposition- Inflammability (short time) or distortion- [ C] temperature [ C] PVC (standard compound) self-extinguishing PVC (compound for telephon cores) self-extinguishing LDPE inflammable HDPE inflammable Foam-PE inflammable Material Water- Weather- Chemical Radioabsorption proof resistance resistance % (general) x10 6 rad PVC (standard compound) 0.4 good limited 17 PVC (compound for telephon cores) 0.4 good limited 17 LDPE 0.1 good limited good 19 HDPE 0.1 limited limited good 19 Schaum-PE 0.1 good limited good 19 Material Relative Density Tensile Breaking Letterpermittivity strength elongation symbol ε [g/cm 3 ] [MPa] % PVC (standard compound) Y PVC (compound for telephon cores) Y LDPE Y HDPE Y...HD Foam-PE Y General Information Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 105

106 Common Explanations RAL-colour code colour- colour huenumber expresion 1001 beige beige 1012 yellow lemon yellow 1013 white oyster white 1014 ivory ivory 1015 beige light ivory 1016 yellow sulfur yellow 1019 beige grey beige 1021 yellow rape yellow 2000 orange yellow orange 2002 orange vermilion 2003 orange pastel orange 2004 orange pure orange 3000 red flame red 3002 red carmine red 3004 red purple red 3015 pink light pink 4001 violet red lilac 4003 violet hether violet 4005 violet blue lilac 5002 blue ultramarine blue 5010 blue gentian blue 5012 blue light blue 5014 blue pigeon blue colour- colour huenumber expresion 5015 light blue sky blue 5019 blue capri blue 6000 green patina green 6001 green emerald green 6003 green olive green 6005 green moss green 6010 green grass green 6018 green yellow green 6027 turquoise light green 7000 grey squirrel grey 7001 grey silver grey 7021 grey black grey 7032 grey (ptt grey) pebble grey 7035 grey light grey 7037 grey dusty grey 8003 brown clay grey 8011 brown nut brown 8014 brown sepia brown 8024 brown beige brown 9001 white cream 9005 black jet black 9007 silver grey grey aluminium 9010 white pure white 106 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

107 Behaviour in Case of Fire, Fire Away Line, Fire Load Requirement In the European standards EN 50167, EN and EN data cables with halogen-free outer sheath are required. The consideration and adherence to these standards are recommended particularly with public setting e.g. hospitals, schools and airports. In addition with other buildings with high person or real value concentration a use of halogen-free cables is practical. Cable with PVC-sheath In the case of fire standard PVC materials can transmit fires and form hydrochloric acid (HCI) by splitting off hydrogen chloride gas in connection with moisture (e.g. fire fighting water). It continues to co me to a strong smoke development with burning PVC (polyvinyl chloride) and the corrosive damage at buildings and equipment can often devastating extents assume, which exceed far the actual fire damage. Testing method according to IEC Samples From the end of the tested cable a sample piece of 600±25 mm is taken. Preparation (fig.1) Propane from cylinder with burner, flame height 175 mm. Sample is hung up vertically into the center of a metal box, (metal box: h=1200±25 mm, b=300±25 mm, t=450±25 mm, front open). Flame cone of the gas burner has to be fixed in an angle of 45 approx. 100 mm above the lower sample. With cable diameter up to 50 mm one burner is used, with cable diameter over 50 mm two burners are used. Execution t = 60 + m 25 t = duration of the flaming action in s m = weight of the sample in g Cables with halogenfree sheath Hereby materials are used, which do not contain halogens (e.g. chlorine) and which do not set free corrosive gases in the case of fire. Also the proportion of toxic gases is reduced to a minimum, and smoke development and fire away line are hardly still available or possible. Designation notes at the cable are e.g. the abbreviations FRNC or LSOH. In detail these designations are meaning: FR flame retardant (fire-away-line-restraining) NC non corrosiv (no corrosive constituents) LS low smoke (low smoke development) 0H zero halogen (halogen-free) Another big advantage by using such materials is, that the free view on gears and escape routes is kept. Please note that you have to take care that such kinds of materials are also used by other products, e.g. power cables or cable run channels. Fire load [kwh/m], [MJ/m] In each building there are many different inflammable installations or products. Also cable and cores (although hidden in intermediate ceilings or channels), which can in particular represent a substantial component in administration buildings belong to them. These cables have most divergent powers (heat values) and the total fire load of a building could clearly increase. Therefore you should be pay attention to the fact, when planning that the fire load quantities are kept as small as possible. Analysis The test is considered as positively passed if the sample did not burn or the flames automatically go out and the fire damage does not reach the upper end of the sample. Fire-pure e.g. soot lining and colour modification are not does claimed. Testing method according to IEC Samples From the end of the tested cable a sample piece of 600±25 mm is taken. Preparation Propane from cylinder with burner, flame height 125 mm. Sample is hung up vertically into the center of a metal box, (metal box: h=1200±25 mm, b=300±25 mm, t=450±25 mm, front open). Flame cone of the gas burner has to be fixed in an angle of 45 approx. 100 mm above the lower sample. Execution max. 20s Analysis The test is considered as positively passed if the sample did not burn or the flames automatically go out and the fire damage does not reach the upper end of the sample. Fire-pure e.g. soot lining and colour modification are not does claimed. General Information Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 107

108 Behaviour in Case of Fire, Fire Away Line, Fire Load Testing methodes according to IEC Samples From the end of the tested cable sample pieces of 360 mm are taken. The number of samples depends on the cable diameter. Testing method 1 Testing methode 3 Preparation (fig. 2) The samples are arranged at the test rack as follows: Telecommunication cables and cords as well as control cables and cords with an outside diameter 30 mm without distance. The number has to be selected in such a way that the grouping width results of min.180 mm; the distance of the outside samples to the lateral side piece of the ladder should be approx. 90 up to 120 mm; mounting of the samples with steel wires; the test rack is inserted vertically into the suspension of the furnace. Dimensions of the furnance as well as air volume and temperature are exactly regulated. Burner, 77.7±4.8 l/min propane and 13.5±0.5 l/h air measured at 20 C and 1 bar. Before starting the test the test set-up has to be conditioned at room temperature for mind. 16 h. Flame of the gas burner has to be fixed in an angle of 90 approx. 600 mm above the lower sample end, in a distance of 75 mm. Execution Duration of the flaming action at least min. 20 minutes Analysis The test is considered as positively passed if the sample did not burn or the flames automatically go out and the fire damage does not reach the upper end of the sample. Fire-pure e.g. soot lining and color modification are not does claimed. Fig.1 Fig.2 The test according to test type 3 shows very realistically the possible fire in a vertical duct. 108 Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

109 Nominal Data of Wooden Drums (DIN 46391) Drums according to DIN (dimensions, weights) identification drum flange-diameter barrel-diameter width traverse width carrying drumnumber dimesion D d B b capacity weight [mm] [mm] [mm] [mm] aprrox. [kg] aprrox. [kg] E E E E E E / / E / / E / / E / / E / / / E E / E up to drum dimension 10 with cable bushing General Information Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations 109

Construction guideline

Construction guideline 1/6 1) SUMMARY OF ABBREVIATIONS FOR CABLE CONSTRUCTION ELEMENTS MSR - : EUPEN code for INSTRUMENTATION CABLES JE - : cable for INDUSTRIAL ELECTRONICS RD - : cable for CONTROL SYSTEMS INSULATION MATERIALS:

More information

RT/ZHLS, A-2Y(L)2Y External Telephone Cables to NR/PS/TEL/00015

RT/ZHLS, A-2Y(L)2Y External Telephone Cables to NR/PS/TEL/00015 RT/ZHLS, A-2Y(L)2Y External Telephone Cables to NR/PS/TEL/00015 The cables are designed primarily for trackside railway installation in non electrifi ed area. For direct burial application, brass tape

More information

CABLEMASTER CABLE GUIDE

CABLEMASTER CABLE GUIDE CABLEMASTER COAXIAL, DATA, TELEPHONE & SPECIAL CABLES CABLE GUIDE REFERENCES: FOXTEL F10231, F30128 OPTUS SAP17874, SAP4868 AS/ACIF S008:2001 N2020 Skandia Pty Ltd Issue: 2.0 Revision: 1 Date of issue:

More information

DATA NETWORK TECHNOLOGY

DATA NETWORK TECHNOLOGY DATA NETWORK TECHNOLOGY 236 COPPER COMPONENTS Individual. Dynamic. Adaptive. Solutions for Industry 4.0 the Internet of Things What once seemed a distant and unrealistic goal has now become business as

More information

Data sheet chainflex CFSPECIAL.182

Data sheet chainflex CFSPECIAL.182 Ethernet (CAT5/CAT5e/GigE/PoE) Profinet (Type C) 1 / 8 Cable structure Conductor Core insulation Stranded conductor in especially bending-resistant version consisting of bare copper wires (following DIN

More information

Content HYBRID AND SPECIAL CABLES G 2 NEW NEW NEW NEW. page. Applications... G/3. Construction examples of special cables

Content HYBRID AND SPECIAL CABLES G 2 NEW NEW NEW NEW. page. Applications... G/3. Construction examples of special cables Hybrid and Special Cables HYBRID AND SPECIAL CABLES Content Applications................................................................................ /3 page Construction examples of special cables

More information

Halogen-free data transmission cable with colour code acc. to DIN resistant to a wide range of chemical media

Halogen-free data transmission cable with colour code acc. to DIN resistant to a wide range of chemical media Halogen-free data transmission cable with colour code acc. to DIN 47100 - resistant to a wide range of chemical media :Screened low-freq data cable Twisted pairs Biopetroleum/ cleaner/ hotwater/ hydraulic

More information

Comparison of BS 5308, PAS 5308 and BS EN

Comparison of BS 5308, PAS 5308 and BS EN Comparison of BS 5308, PAS 5308 and BS EN 50288 Scope BS 5308 Part 1: 1986- Instrumentation Cables Part 1. Specification for Polyethylene Insulated Cables (withdraw, superseded by BS EN 50288-7) BS 5308

More information

H-FLEX CABLES 10/2017

H-FLEX CABLES 10/2017 10/2017 H-FLEX CABLES CONTENTS H-FLEX PWR PUR 0,6/1kV...2 H-FLEX PWR C-PUR 0,6/1kV...6 H-FLEX CTL PUR 250V...10 H-FLEX CTL C-PUR 250V...12 H-FLEX INS PUR 250V...14 H-FLEX INS C-PUR 250V...16 TECHNICAL

More information

Caledonian Cables Ltd

Caledonian Cables Ltd Caledonian Motor Connection Cable Caledonian Cables Ltd s 1 Addison Addison Motor Connection Cable Company Profile Caledonian. established in 1978.offers one of the most complete lines of fiber and copper

More information

Data sheet chainflex CF887

Data sheet chainflex CF887 1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Filling: Plastic yarns 4. Core insulation: Mechanically high-quality, especially low-capacitance

More information

Lift Control Cables www.sab-worldwide.com The Company DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control technique as well as in cable production have made a one man

More information

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed] [6.35/11kV Copper XLPE Three-Core HDPE Sheathed] APPLICATION Mostly used as feeder electric cable for power distribution network such as power supply station, substation, switching system etc. They are

More information

The Company by Peter Bröckskes sen. an independent, middle sized company

The Company by Peter Bröckskes sen. an independent, middle sized company The Company DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control technique as well as in cable production have made a one man business a company with nearly 500 staff

More information

Content. Festoon 715 P PUR cable for flexible application in festoon systems... G/21

Content. Festoon 715 P PUR cable for flexible application in festoon systems... G/21 Hybrid and Special Cables HYBRID AND SPECIAL CABLES Content 2 page Applications... /3 Construction examples of special cables: CAN-Bus cable... /4 Profibus-DP cable... /5 Coupling cable... /6 Interbus

More information

Article number: Sheath marking ACE - TKF LTC-S RP 24x SM G.657.A1 6x4 A-DQ(ZN)B2Y {Batch} {Year} {Length}

Article number: Sheath marking ACE - TKF LTC-S RP 24x SM G.657.A1 6x4 A-DQ(ZN)B2Y {Batch} {Year} {Length} Description 24x SM G.657.A1 (6x4) The Loose Tube Cable Slim Rodent-Protected () is a non-metallic, loose tube outdoor duct cable, rodent protected, longitudinal water-protected, with high pulling force.

More information

Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant PUR sheath

Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant PUR sheath Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant PUR sheath - Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant

More information

AMWAJ TELECOMMUNICATION FACTORY

AMWAJ TELECOMMUNICATION FACTORY AMWAJ TELECOMMUNICATION FACTORY PRODUCT PROFILE (DROP WIRES & JUMPER WIRES) PO Box 325934 Riyadh 11371 Kingdom of Saudi Arabia Tel: +966 11 4004718 / 4009204, Fax: +966 11 4008027 Website: www.amwajfactory.com

More information

Cables for robots www.sab-worldwide.com CONTENT page < The company............................................................................... < Clientele / supplier numbers........................................................................

More information

FieldLink for PROFIBUS Applications

FieldLink for PROFIBUS Applications FieldLink for PROFIBUS s The Automation & Drives business unit of LEONI has developed FieldLink bus cables in accordance with the PROFIBUS specifications. The FieldLink bus cable product range for PROFIBUS

More information

Cables de Comunicaciones Zaragoza. CW1601 Approval application.

Cables de Comunicaciones Zaragoza. CW1601 Approval application. 1. GENERAL INFORMATION 1.1 LIST OF CONTENTS Cables de Comunicaciones Zaragoza. CW1601 Approval application. 1. General Information 1.1 List of Contents 1.2 Contractors Name 1.3 Test report 1.4 Product

More information

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath 0.6/1 kv LOW VOLTAGE CONTROL CABLES PVC OR XLPE INSULATED, PVC SHEATHED AS PER IEC 60502-1 Conductors Conductors shall be Circular Stranded, Class 2 as per IEC 60228, BS EN 60228. Upon request, Solid Circular

More information

Armoured Instrumentation Cables to BS7917

Armoured Instrumentation Cables to BS7917 Armoured Instrumentation Cables to BS1 Fire Resistant, Pairs/Triples - Collectively Screened. Low Smoke Zero Halogen TAC, MGT, EPR, SCRN, ZH, GSWB, SW 0/0V Application Control and instrumentation cable

More information

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified - Screened power and control cable for versatile use in power chains with UL/cUL AWM certification.

More information

Highly flexible control cable with PVC core insulation and PVC sheath - certified for North America

Highly flexible control cable with PVC core insulation and PVC sheath - certified for North America Highly flexible control cable with PVC core insulation and PVC sheath - certified for North America - Power and control cable for versatile use in power chains with UL/cUL AWM certification Info Basic

More information

PURENET-U (Part No.: U RXX2, U PXX2)

PURENET-U (Part No.: U RXX2, U PXX2) ISSUED: FEB. 3, 2010 PAGE : 1 OF 6 PURENET-U5350-00 (Part No.: U5350-04-RXX2, U5350-04-PXX2) for 4 PAIR UTP CABLES (ENHANCED CATEGORY 5E) ( Ref.: UL 444, ANSI/TIA/EIA-568B.2 & ISO/IEC 11801,IEC 61156-5

More information

HELUKABEL CC-Link Certified Cables

HELUKABEL CC-Link Certified Cables Data, Network & BUS Technology HELUKABEL CCLink Certified Cables HELUKABEL provides you with all cable types for your CCLink network, approved by the CLPA organization. In addition to the classic red 3conductored

More information

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE TI 20 PVC TI 20 INSULATED TELEPHONE WIRE Standard: Nominal voltage: Temperature range - fixed laying: Cable Structure: Application: Packing: 2x0,5 0,4 2,6 3,6 7,2 2x0,6 0,4 2,8 5,2 9,1 2x0,8 0,4 3,2 9,2

More information

INSTRUMENTATION, CONTROL AND THERMOCOUPLE CABLES

INSTRUMENTATION, CONTROL AND THERMOCOUPLE CABLES Conducting Value INSTRUMENTATION, CONTROL AND THERMOCOUPLE CABLES 400/7 ISO 900:08 Certificate No. CS-249 MANAGEMENT SYSTEMS Assessed to ISO 900:08 Cert/LPCB ref. 27 GOST ISO 900- (ISO 900:08) certification

More information

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified - Screened power and control cable for versatile use in power chains with UL/cUL AWM certification.

More information

CONSULTATIONS TECHNICAL GUIDELINE. HVDC extruded cable

CONSULTATIONS TECHNICAL GUIDELINE. HVDC extruded cable UNIT, BU1SNESS AREA OUR REFERENCE TR14-02-2E DATE 2018-01-24 CONSULTATIONS TECHNICAL GUIDELINE EDITION 1 APPROVED HVDC extruded cable This technical guideline describes the basic design and construction

More information

SPECIFICATION FOR FRLS POWER CABLES

SPECIFICATION FOR FRLS POWER CABLES SPECIFICATION FOR FRLS POWER CABLES 1.0 SCOPE This specification cover the technical requirements of design, manufacture, testing and delivery to site of Power Cables of 1100V grade with FRLS PVC Sheathed,

More information

Reeling Cables www.sab-worldwide.com CONTENT page The Company....................................................................................................... 2 DR 717 P Highflex 300/500 V.........................................................................................

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION 4 PAIR UTP CABLE CAT6 (CATEGORY 6 PLUS) Page 1 of 5 1. SCOPE This specification is based on the specifications of UL 444, ANSI/TIA/EIA-568-B,ISO/IEC 1801, UL 1685(CM) and covers

More information

Content. PV1-F Halogen-free cable for photo-voltaic systems... G/11. PV1-F dual Halogen-free twin cable for photo-voltaic systems...

Content. PV1-F Halogen-free cable for photo-voltaic systems... G/11. PV1-F dual Halogen-free twin cable for photo-voltaic systems... Hybrid and Special Cables HYBRID AND SPECIAL CABLES Content page Applications... /3 Construction examples of special cables: CAN-Bus cable... /4 Profibus-DP cable... /5 Coupling cable... /6 Interbus Hybrid

More information

RG-59, RG-59+2DC, UTP CAT6, SFTP CAT6

RG-59, RG-59+2DC, UTP CAT6, SFTP CAT6 FLAT ELEVATOR CABLE RG59, RG59+2DC, UTP CAT6, SFTP CAT6 COPPER SERIES MAIN FEATURES ASTEL RG59 Lift Monitor cablescopper Series are designed and manufactured to Ultra flexibility demand of CCTV Cameras

More information

Separator, suitable tape between the braid and outer sheath

Separator, suitable tape between the braid and outer sheath Picture is for information only. Applicable standards: NEK TS 606 Code S1/S5, IEC 60092-376- Design guidelines IEC 60228 conductor IEC 60092-351 Insulating material, IEC 60092-359 Sheathing materials IEC

More information

IP68 Quick connection system. IP68 Quick connection system

IP68 Quick connection system. IP68 Quick connection system IP68 Quick connection system IP68 Quick connection system Woertz IP 3G2.5 mm 2 and Woertz IP 3G4 mm 2 A high protection degree, short installation procedures, easy handling and expansion possibilities

More information

Instrumentation and Thermocouple Cables

Instrumentation and Thermocouple Cables Conducting Value Instrumentation and Thermocouple Cables 400/4 Instrumentation and Thermocouple Cables CAVICEL 4 Construction and General Information 6 Construction 6 Noise 0 Thermocouple extension and

More information

Instrumentation and Thermocouple Cables

Instrumentation and Thermocouple Cables Conducting Value Instrumentation and Thermocouple Cables 400/3 Instrumentation and Thermocouple Cables CAVICEL 4 Construction and General Information 6 Construction 6 Noise 0 Thermocouple extension and

More information

Electric cables. CRANES APPENDIX

Electric cables. CRANES APPENDIX Electric cables. CRANES APPENDIX Electric cables for mobile connections. Aristoncavi spa reserve the right to modify the data in this catalogue without notice. 06/0 Copyright Drawings and technical descriptions

More information

EHV XLPE CABLES CDCC LINE

EHV XLPE CABLES CDCC LINE PROFILE THE HINDUSTHAN VIDYUT PRODUCTS LIMITED, established in the year 1959 is a leading manufacturer of Overhead Conductors and Underground Cables. The Company at its Faridabad Works has sophisticated

More information

Coaxial Cables for Broadband Communication Networks European Edition

Coaxial Cables for Broadband Communication Networks European Edition Belden Coaxial Cables for Broadband Counication Networks European Edition Belden Coaxial Cables for Broadband Dependable Solutions in Cabling Better by design Our strategic objective is to provide our

More information

HELUKABEL CC-Link Certified Cables

HELUKABEL CC-Link Certified Cables Data, Network & Bustechnology HELUKABEL CCLink Certified Cables The HELUKABEL GmbH provides you with all cable types for your CC Link network, approved by the CLPA organization. In addition to the classical

More information

M-FLEX CONTROL CABLES

M-FLEX CONTROL CABLES M-FEX COTRO CABES Flexible, workable and environmentally resistant. FOR IDUSTRY Your reliable partner for integrated industrial cable solutions. Prysmian Group is world leading in the development and production

More information

CONTENT. Robot cables. page. < The company < W - worldwide < Certifications < Clientele / supplier numbers... 6

CONTENT. Robot cables. page. < The company < W - worldwide < Certifications < Clientele / supplier numbers... 6 CONTENT page < The company............................................................................... 3 < W - worldwide...............................................................................

More information

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics ENERGY PROTOLON(SMK) LWL (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics Technical Data Type Type designation Approvals/ standards Application PROTOLON (SMK) LWL (N)TSKCGEWÖU DIN

More information

Instrumentation Cables

Instrumentation Cables Instrumentation Cables Product Catalogue Factories and Regional Offices Tai Sin Electric Limited 24 Gul Crescent Jurong Town Singapore 62953 Tel: (+65) 6672 9292 Fax: (+65) 686 4084 E-Mail: sales@taisin.com.sg

More information

loop 0.60 mh/km 0.65 mh/km RCCY031/032 /KS1 RCCY031/032 /NS mh/km 0.70 mh/km RCCY033/034 /KS1 RCCY033/034 /NS1

loop 0.60 mh/km 0.65 mh/km RCCY031/032 /KS1 RCCY031/032 /NS mh/km 0.70 mh/km RCCY033/034 /KS1 RCCY033/034 /NS1 Drawings Models RCCY031, RCCY032, RCCY033, RCCY034 Coriolis Mass Flow and Density Meter Remote Cable Specification: Li2Y(St)/CY 3x2 AWG24 + 1x3 AWG20, pair/triple shielded; pair/triple twisted; overall

More information

Application (easy to strip) ES cable for permanent installation. and mechanical stress (easy to strip) 1x2x22AWG 1

Application (easy to strip) ES cable for permanent installation. and mechanical stress (easy to strip) 1x2x22AWG 1 PROFIBUS DP ES PROFIBUS DP ES PROFIBUS DP ES ES cable for permanent installation ES cable for permanent installation ES sturdy cable for chemical (easy to strip) (easy to strip, FRNC) and mechanical stress

More information

Reeling Cables www.sab-worldwide.com THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control technique as well as in cable production have made a one man business

More information

Type 1 Machine Cable. Oxygen free tinned annealed copper wire interwoven with high tensile poly-yarn

Type 1 Machine Cable. Oxygen free tinned annealed copper wire interwoven with high tensile poly-yarn Mining Cable Type 1 Machine Cable Application: Typically used for interconnection of control boxes or motors on non-mobile or fixed apparatus. Used when exposure to heat is not an issue and where added

More information

Fibre optic cables CTC LSZH 1,2kN

Fibre optic cables CTC LSZH 1,2kN CTC LSZH,kN CTC LSZH,kN - Universal, Metallfree, Central Tube Cable. Light-weight, non-metallic, universal central tube cable (indoor/outdoor) with small diameter, rodent protected, longitudinal water-protected,

More information

MANUFACTURER'S QUALITY ASSURANCE PLAN (QAP - Instrumentation cables)

MANUFACTURER'S QUALITY ASSURANCE PLAN (QAP - Instrumentation cables) POLARIS CABLES & WIRES PVT. LTD. (An IS & ISO 9001 :2000 Certified Company) Plant : Plot 35, Genesis Indl Complex, Kolgaon, PALGHAR, Dist :Thane, Maharashtra. MANUFACTURER'S QUALITY ASSURANCE PLAN (QAP

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTENATIONAL STANDAD IEC 60708 First edition 2005-06 Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath eference number IEC 60708:2005(E) Not for esale Publication numbering

More information

INDUSTRY. Welding Cables. Highly flexible, resistant and robust.

INDUSTRY. Welding Cables. Highly flexible, resistant and robust. INDUSTRY Welding Cables Highly flexible, resistant and robust. Flexible welding cables Weather resistant and robust These cables are designed for connection between welding apparatus and electrode as well

More information

Photo: HELUKABEL. Robotic Cables H 1

Photo: HELUKABEL. Robotic Cables H 1 Photo: HELUKABEL Robotic Cables H 1 Robotic Cables With over 30 years of experience with cables and lines, we also have the right solutions for the demands placed on the components to be installed by the

More information

138-1: 2015 CEB SPECIFICATION. AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 )

138-1: 2015 CEB SPECIFICATION. AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 ) 138-1: 2015 CEB SPECIFICATION AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 ) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 8051 Fax: +94 11 232 5387 CONTENTS Page 1.0 Scope 3 2.0 System

More information

Available in 0.75 to 16.0 sq mm. Red, Yellow, Blue, Black, White, Gray and Green (for earthing) Specification IS 694:1990

Available in 0.75 to 16.0 sq mm. Red, Yellow, Blue, Black, White, Gray and Green (for earthing) Specification IS 694:1990 Application These cables are used for wiring domestic and coercial buildings. The multi strand flexible conductors make it ideal for concealed wiring. These cables are ideal for wiring in residential and

More information

MATERIAL STANDARD FOR CABLES AND WIRES

MATERIAL STANDARD FOR CABLES AND WIRES MATERIAL STANDARD FOR CABLES AND WIRES CONTENTS : PAGE No. 1. SCOPE... 2 2. SERVICE CONDITIONS... 2 3. REFERENCES AND STANDARDS... 2 4. UNITS... 3 5. CABLE DESIGN AND CONSTRUCTION... 3 5.1 Applicable Cable

More information

BUS CABLES. Content. IBL 600 PVC Interbus-Loop cable... E/11. S IBL 605 PUR Interbus-Loop cable for cable tracks... E/11

BUS CABLES. Content. IBL 600 PVC Interbus-Loop cable... E/11. S IBL 605 PUR Interbus-Loop cable for cable tracks... E/11 Bus Cables BUS CABLS Content page Applications... /5-6 Interbus-S cables remote bus cables IBS 612 PVC Interbus-S cable for indoor and outdoor installation... /7 IBS 617 PVC Interbus-S cable with UL recognition...

More information

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables Version: 4.1 Date of Issue: February 2016 Page: 1 of 25 NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables 1. Purpose The purpose of this document is to detail the requirements

More information

Compact Module. Enhanced Category 5 FTP Cabling System

Compact Module. Enhanced Category 5 FTP Cabling System Compact Module Enhanced Category 5 performance Suitable for Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro modules and blanks Individually QA tested Easy to use

More information

XLPE MATERIAL NATIONAL CABLES INDUSTRY XLPE INSULATED MEDIUM VOLTAGE CABLES

XLPE MATERIAL NATIONAL CABLES INDUSTRY XLPE INSULATED MEDIUM VOLTAGE CABLES XLPE MATERIAL The trend of cross-linked polyethylene insulated cables into power cables field is quite prevalent in the world as the substitutes of paper insulated cables, which had played the leading

More information

Copper Cable Company Limited

Copper Cable Company Limited Cables and Wires Copper Cable Company Limited Copper Cable Company is the UK subsidiary of TELE-FONIKA Kable S.A., with offices and a warehouse centrally located in Leicestershire. 2 A major supplier to

More information

Cable solutions for Automation & Drives

Cable solutions for Automation & Drives www.leoni-industrial-solutions.com Cable solutions for Automation & Drives The Quality Connection Issue 11/2013 All FieldLink products are permanentely enhanced for our customers. Therefore this brochure

More information

SUBMERSIBLE. Electric cables

SUBMERSIBLE. Electric cables SUBMERSIBLE Electric cables Aristoncavi spa reserve the right to modify the data in this catalogue without notice. 06/06 Copyright Drawings and technical descriptions in this catalogue may not, under penalty

More information

Product overview. Product characteristics. Article number Cables - Universal Print Date

Product overview. Product characteristics.   Article number Cables - Universal Print Date 77824 Article number 77824 Group Cables - Universal Print Date 24-10-2016 Product overview The ACE universal optical fibre cables are suitable for both indoor and outdoor situations. These cables offer

More information

WIND TURBINES DEDICATED CABLES LV AND MV VOLTAGE RUBBER CABLES

WIND TURBINES DEDICATED CABLES LV AND MV VOLTAGE RUBBER CABLES WIND TURBINES DEDICATED CABLES LV AND MV VOLTAGE RUBBER CABLES Table of content About Nexans 3 LV and MV voltage rubber cables 4 Cables sets for wind turbines 5 Medium Voltage Jumpers for Wind Application

More information

catalog Copper Wires

catalog Copper Wires catalog Copper Wires ASWire Aerial Service Wire Self Supporting Multi-pair Pair Count 1-18P Multi-pair, self-supporting Aerial Service Wires (ASW) are used for subscriber lines in exchange plant; single-pair

More information

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

NPS/002/020 Technical Specification for 11 & 20kV Power Cables Version:- 3.1 of Issue:- Nov - 09 Page 1 of 11 NPS/002/020 Technical Specification for 11 & 20kV Power Cables 1. Purpose The purpose of this document is to detail Northern Powergrid (the Company) requirements

More information

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV) EDC3 (5239) P3 Mini-Grid Systems DRAFT TANZANIA STANDARD Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV) TANZANIA BUREAU OF STANDARDS TBS 2017 First Edition 2017 Table of Contents

More information

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables Version: 4.0 Date of Issue: October 2015 Page: 1 of 21 NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables 1. Purpose The purpose of this document is to detail the requirements

More information

according to UL AWM 758, Style and based on EN resp. VDE

according to UL AWM 758, Style and based on EN resp. VDE Application ÖLFLEX SERVO FD 798 CP cables are high-flexible, screened, oil-resistant, halogen free, signal (encoder and resolver) cables with an outer sheath of Polyurethane. They are designed for use

More information

New designed XLPE-insulated cables substituting paper-insulated pipe type cables

New designed XLPE-insulated cables substituting paper-insulated pipe type cables MODERN CABLE SYSTEMS IN STEEL PIPES New designed XLPE-insulated cables substituting paper-insulated pipe type cables Volker AUE, Nexans Deutschland Industries, Germany, Volker.Aue@nexans.com Wilfried ROSEBROCK,

More information

Engineering Data for Copper and Aluminum Conductor Electrical Cables

Engineering Data for Copper and Aluminum Conductor Electrical Cables 2018 Edition Engineering Data for Copper and Aluminum Conductor Electrical Cables THE OKONITE COMPANY Okonite Cables...A higher Standard! The Okonite Company, 2018 Okonite Cables Table of Contents SECTION

More information

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable. Spec. No. GO 5821-4361Rev.2 Issued date : July 13, 2005 Revised 1 date : April 29, 2015 Revised 2 date : February 19, 2016 Specification FOR 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated

More information

Cable solutions for Automation & Drives

Cable solutions for Automation & Drives www.leoni-industrial-solutions.com Cable solutions for Automation & Drives The Quality Connection Issue 11/2016 All FieldLink products are permanently enhanced for our customers. Therefore this brochure

More information

YKY, YKY-żo 0,6/1kV PN-93/E-90401, PN-HD-603 S1, IEC

YKY, YKY-żo 0,6/1kV PN-93/E-90401, PN-HD-603 S1, IEC PVC insulated and PVC sheathed power cable CONSTRUCTION Conductors: annealed copper solid class 1(RE), circular or circular compacted stranded conductor class 2 (RM, RMC) or stranded sector shaped conductor

More information

TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE

TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE WITH - SINGLE MODE OPTICAL FIBER (ITU-T G.652D, LWPF) - LOOSE TUBE (JELLY FILLED) - DRY CORE DESIGN - NON-METALLIC STRENGTH MEMBER (FRP + Glass yarns) -

More information

137-1: 2015 CEB SPECIFICATION. XLPE INSULATED SINGLE CORE UNDERGROUND CABLES OF 11 kv RATED VOLTAGE

137-1: 2015 CEB SPECIFICATION. XLPE INSULATED SINGLE CORE UNDERGROUND CABLES OF 11 kv RATED VOLTAGE 137-1: 2015 CEB SPECIFICATION XLPE INSULATED SINGLE CORE UNDERGROUND CABLES OF 11 kv RATED VOLTAGE CEYLON ELECTRICITY BOARD SRILANKA Telephone: +94 11 232 8051 Fax: +94 11 232 5387 CONTENTS Page 1.0 Scope

More information

Power Systems 2 ELE3015. Lecture 1: Transmission Lines

Power Systems 2 ELE3015. Lecture 1: Transmission Lines Power Systems 2 ELE3015 Lecture 1: Transmission Lines Transmission Lines: Introduction Use to carry electrical power from point of generation to the point of use. Usually over large distances. Made with

More information

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, TYPE LSC5FS (INCLUDING VARIATIONS LSC5FSW, LSC5OS, AND LSC5OSW)

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, TYPE LSC5FS (INCLUDING VARIATIONS LSC5FSW, LSC5OS, AND LSC5OSW) INCH-POUND MIL-DTL-24643/59 9 September 2005 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, TYPE LSC5FS (INCLUDING VARIATIONS LSC5FSW, LSC5OS, AND LSC5OSW) This specification is approved for use by all

More information

THE PATHWAY TO POWER HIGH AND EXTRA HIGH VOLTAGE CABLES

THE PATHWAY TO POWER HIGH AND EXTRA HIGH VOLTAGE CABLES THE PATHWAY TO POWER HIGH AND EXTRA HIGH VOLTAGE CABLES TABLE OF CONTENTS HIGH-VOLTAGE CABLES 3 Advantages of XLPE-insulated cable systems 3 PROPOSAL 4 Cable systems 4 Providing System Solutions 4 Continuous

More information

PRODUCT INFORMATION ÖLFLEX CRANE. Info Suitable for outdoor use Integrated supporting element Also suitable for power chains and cable trolley systems

PRODUCT INFORMATION ÖLFLEX CRANE. Info Suitable for outdoor use Integrated supporting element Also suitable for power chains and cable trolley systems Highly flexible and weather-proof rubber cables with support element - flexible cable, flame retardant for outdor use and crane applications/conveyour technology, power and control rubber cable, U 0 /U:300/500V

More information

List Price w.e.f. 24th July, 2018

List Price w.e.f. 24th July, 2018 w.e.f. 24th July, 2018 HRFR/FR-LSH/HFFR/ PVC Insulated Industrial Cables Multicore Round PVC Cables Flat Three Core Industrial Cable for Sumersible use Telecom & Co-axial Cables LAN Cables CCTV Cables

More information

List Price w.e.f. 02nd January, 2018

List Price w.e.f. 02nd January, 2018 w.e.f. 02nd January, 2018 HRFR/FR-LSH/HFFR/ PVC Insulated Industrial Cables Multicore Round PVC Cables Flat Three Core Industrial Cable for Sumersible use Telecom & Co-axial Cables LAN Cables CCTV Cables

More information

Cables for Railway Signalling Applications General Requirements

Cables for Railway Signalling Applications General Requirements Discipline: Engineering (Signalling) Category: Procedure Cables for Railway Signalling Applications General Requirements ESA-11-01 Applicability ARTC Network Wide Primary Source ESA-02-01 Document Status

More information

PHOTOVOLTAIC CABLES. Energy and Fiber Optical Cables for Solar Energy Systems.

PHOTOVOLTAIC CABLES. Energy and Fiber Optical Cables for Solar Energy Systems. PHOTOVOLTAIC CABLES Energy and Fiber Optical Cables for Solar Energy Systems. As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of

More information

TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE

TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE ( Micro loose tube cable ) WITH - SINGLE MODE OPTICAL FIBER (ITU-T G.652D, LWPF) - MICRO LOOSE TUBE (JELLY FILLED) - DRY CORE DESIGN - NON-METALLIC STRENGTH

More information

Rail Wire Guide. Harnessing and Electro-Mechanical Solutions for Demanding, Harsh Environment Applications... LFH FREE

Rail Wire Guide. Harnessing and Electro-Mechanical Solutions for Demanding, Harsh Environment Applications... LFH FREE Harnessing and Electro-Mechanical Solutions for Demanding, Harsh Environment Applications... Railway Market: 100E Wire ZHPCG Cable SHF260 Flexible Cable Rail Wire Guide LFH Low Fire Hazard HALOGEN FREE

More information

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category.

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category. Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category. Superastic Flex Extra sliding for extra easy installation. Superastic Flex cables are ideal for those who want to save installation

More information

Cable solutions for Automation & Drives

Cable solutions for Automation & Drives Cable solutions for Automation & Drives The Quality Connection Issue 08/2018 All FieldLink products are permanently enhanced for our customers. Therefore this brochure is subject to change and error. Up

More information

Wires & Cables for Space Applications

Wires & Cables for Space Applications Wires & Cables for Space Applications Aerospace Business Unit Draka Fileca S.A.S. is part of the Prysmian Group, the world leader in the cable systems industry, listed on the Milan Stock Exchange. With

More information

Fiber Optic Cables. General cable specification

Fiber Optic Cables. General cable specification Fiber Optic Cables General cable specification CONTENT CODING OF FIBER OPTIC CABLES ACCORDING TO THE VDE 0888 COLOUR CODING CHARTS SINGLE-MODE FIBER ITU-T G.652.D BEND INSENSITIVE SINGLE-MODE FIBER ITU-T

More information

Single core conductor BETAtherm 145

Single core conductor BETAtherm 145 Internet: www.synflex.de Single core conductor BETAtherm 145 Description BETAtherm 145 is a flexible low-voltage cable with UL recognition consisting of a tinned copper stranded wire and insulated with

More information

Cable solutions for Automation & Drives

Cable solutions for Automation & Drives www.leoni-factory-automation.com Cable solutions for Automation & Drives The Quality Connection Issue 08/2018 All FieldLink products are permanently enhanced for our customers. Therefore this brochure

More information

CREATE NETWORKS. project business by LAPP

CREATE NETWORKS. project business by LAPP CREATE NETWORKS project business by LAPP Customer-oriented, success-oriented, family-oriented, innovative. LAPP. From the very start, the company founders Oskar and Ursula Ida Lapp had a clear vision of

More information

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) DELHI METRO RAIL CORPORATION LIMITED DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) SPECIFICATION NO. DMES- T/0018/ DMRC-E-TR-CABLE-2 SPECIFICATIONS FOR 33 kv CABLES FOR ELEVATED AND Issued on: Date Stage

More information

Electrical Insulating Tapes

Electrical Insulating Tapes Electrical Insulating Tapes Energy, Mining, Industrial and Contractors applications LV and MV electrical jointing and termination applications Adhesive or Self-amalgamating UV resistant Cold and weather

More information