VERTICAL SEAM TABLE OF CONTENTS

Size: px
Start display at page:

Download "VERTICAL SEAM TABLE OF CONTENTS"

Transcription

1 TABLE OF ONTENTS Product Page No. Product Page No. Panel Information Vertical Seam Panel Profi les... PVS- Panel Overview... PVS- Flashing Profiles Eave... PVS- Extended Eave... PVS- leat... PVS- Offset leat... PVS- Box Gutter... PVS- Box Gutter End... PVS- Universal Gutter/Downspout Strap... PVS- " x / " Downspout... PVS- " x / " 95 Elbow... PVS- Downspout Bracket... PVS- Valley... PVS- Rake... PVS- Rakewall... PVS- ounter Flashing... PVS- Reglet Flashing... PVS- " Ridge/Hip over... PVS- SSR Ridge... PVS- Vented Ridge over... PVS- Vent Drip... PVS- Peak... PVS- Pitch Break... PVS- Z-losure... PVS-.5" Sill/Head... PVS-.5" Sill to Soffi t... PVS- Starter... PVS- Accessory Profiles Vertical Seam lip... PVS-5 Vertical Seam lip (UL-90)... PVS-5 Floating Rake Angle... PVS-5 Back-Up hannel... PVS-5 Bearing Plate... PVS-5 Vent Material... PVS-5 Rubber Roof Jack... PVS-5 Retro Roof Jack... PVS-5 Rubber Roof Flashing Kit... PVS-5 Tube Sealant... PVS-5 Tape Sealant... PVS-5 Touch-Up Paint... PVS-5 Metal Panel Hemming Tool... PVS-5 Design/Installation onsiderations Fastener Installation Technique... PVS-5 ondition of Substructure... PVS-5 Ventilation... PVS-6 Insulation... PVS-6 System Expansion/ontraction... PVS-7 Selection of System omponents... PVS-7 Detail onditions Eave Detail... PVS-8 Extended Eave Detail... PVS-9 Box Gutter Detail... PVS-9 Valley Detail... PVS-0 Rake (On Module) Detail... PVS- Rake (Off Module) Detail... PVS- Rake Parapet (On Module) Detail... PVS- Rake Parapet (Off Module) Detail... PVS- SSR Ridge/Hip Detail... PVS- Vented Ridge Detail... PVS-5 Highside Parapet Detail... PVS-5 Notes Notes... PVS-6 Testing Information UL 580 Wind Uplift Information...PVS-6- UL Fire Resistance Ratings... PVS- Section Properties and Load Tables... PVS- PVS-

2 PANEL OVERVIEW PANEL PROFILES Factory Applied Sealant /" Without Striations (Flat) ",6", or 8" overage Factory Applied Sealant /" With Striations ",6", or 8" overage SLOPE SUBSTRATE OVERAGE LENGTH AVAILABILITY APPLIATION PERFORMANE TEST FASTENING SYSTEM FASTENERS MATERIALS FINISH The minimum recommended slope for any Vertical Seam roofing panel is :. Vertical Seam is designed to be utilized over solid substrate, but can easily be used over an open structural framing. The recommended substrate is 5 /8" plywood with a 0 pound felt moisture barrier. To avoid panel distortion, use a properly aligned and uniform substructure. Vertical Seam panels are available in a ", 6", and 8" width with a /" rib height. Lengths under 5'-0" are available with some cutting restrictions. Maximum recommended panel length is 5'-0". Longer panels require additional consideration in packaging, shipping, and erection. Please consult your Metal Sales branch for recommendations (see PGI- and for locations). Vertical Seam panels are available in 6,, and gauge. Minimum quantities may apply. ommercial, Architectural, and Residential panel. UL 580, ASTM E-59, ASTM E-66, ASTM E-680, UL 790, UL 8, UL 6, Texas Department of Insurance, Miami-Dade ounty. oncealed lip System. The fastener selection guide should be consulted for choosing proper fasteners for specific applications. Quantity and type of fastener must meet necessary loading and code requirements (see PGI--). Steel grade 50, Per ASTM-A79 * Acrylic oated Galvalume (AG) / ASTM A-79 - AZ55 Prepainted Galvalume / ASTM A-79 - AZ50 ** Fluorocarbon (PVDF) * Differential appearance of Acrylic oated Galvalume roofing materials is not a cause for rejection. ** Meets both Kynar 500 and Hylar 5000 specifications. PVS-

3 EAVE FLASHING PROFILES EXTENDED EAVE LEAT 7 /8" X* " Hem 5 /8" X* 6" " 5 /8" /" /" /" 5 Length 0'-" - *Specify Slope Angle Length 0'-" *Specify Slope Angle Length 0'-" OFFSET LEAT BOX GUTTER BOX GUTTER END /" /" " /" X* 5" " Hem " " 5" " " " 5" 5" Length 0'-" UNIVERSAL GUTTER/ DOWNSPOUT STRAP Hem Length 0'-", 0'-" - *Specify Slope Angle DOWNSPOUT " x /" 95 0 ELBOW " x /" " /" " /" 6" DOWNSPOUT BRAKET /" VALLEY Length 0'-", 0'-" (Also available 6" x ") (Also available 6" x ") (Also available in 5 ) RAKE " " " X* 0" 5" RAKEWALL (Also available 6") Length 0'-", 0'-" - *Specify Slope Angle OUNTER FLASHING 5 /8" Hem Length 0'-", 0'-" REGLET FLASHING /" " 5 /8" " /" " " /" Hem Length 0'-", 0'-" /" Length 0'-" Hem Length 0'-" PVS-

4 " RIDGE/HIP OVER FLASHING PROFILES (ONT.) SSR RIDGE VENTED RIDGE OVER 5 /" X* 5 Hem X* " " " " Hem " " X* /8" 7 /8" Length 0'-", 0'-" - *Specify Slope Angle Length 0'-", 0'-" - *Specify Slope Angle Length 0'-", 0'-" - *Specify Slope Angle VENT DRIP /" 60 /" 0 PEAK 5" X* 6" PITH BREAK X* " /" /8" 6" Length 0'-" Length 0'-", 0'-" - *Specify Slope Angle Length 0'-", 0'-" - *Specify Slope Angle Z-LOSURE ".5" SILL/HEAD.5" SILL TO SOFFIT /" /" /" /" /" /" /" " Length 0'-" Length 0'-", 0'-" /" Length 0'-", 0'-" STARTER /" /" - Indicates color side of flashing. Length 0'-" PVS-

5 AESSORY PROFILES VERTIAL SEAM LIP VERTIAL SEAM FLOATING RAKE ANGLE UL-90 LIP Length 0'-0" Height / " Galvanized BAK-UP HANNEL BEARING PLATE VENT MATERIAL /8" 7 /8" " Length 8" and 7" Galvanized RUBBER ROOF JAK " X 5" RETRO ROOF JAK RUBBER ROOF FLASH KIT MINI ( /" to /8" O.D. Pipe) # ( /" to " O.D. Pipe) # (" to 6" O.D. Pipe) #6 (6" to 9" O.D. Pipe) #8 (7" to " O.D. Pipe) TUBE SEALANT #80RETRO ( /" to /" O.D. Pipe) #80RETRO (" to 7 /" O.D. Pipe) #80RETRO ( /" to 0" O.D. Pipe) TAPE SEALANT " x 50'-0" Flash Kit 8" x 50'-0" Flash Kit TOUH-UP PAINT 0. oz. artridge Urethane METAL PANEL HEMMING TOOL 7 /8" X /6" X 5' Double Bead Butyl - Gray Available in Pints PVDF / MS F0 PVS-5

6 UL 580 WIND UPLIFT INFORMATION See Item VERTIAL SEAM onstruction No. 5 February 05, 00 Uplift - lass 90 (See Item No. ) Fire Not Investigated. Metal Roof Deck Panels * No. MSG or No. MSG min thickness coated steel panels. Panels in. wide, -/ in. high at the ribs. Panels continuous over two or more spans. A bead of sealant may be used at panel side joints. METAL SALES MFG ORP - Vertical Seam. Roof Deck Fasteners * (Panel lips) One piece assembly, -/ in. wide, -7/8 in. high, thickness 0.08 in. One panel clip located at each purlin intersection. METAL SALES MFG ORP - Vertical Seam lip. Panel Fasteners (Screws) Fasteners used to attach panel clips (Item ) to purlins to be No. 0-6 by in. long No. self-drilling point, No. Phillips drive head, plated steel screws. Two screws per clip to be used inserted through / in. diameter guide holes.. Purlins No. 6 MSG min thickness steel (50,000 psi min yield strength). Spacing - For MSG thickness panels - 60 in. O For MSG thickness panels - 8 in. O U L Underwriters Laboratories Inc. LISTED PVS-6

7 UL 580 WIND UPLIFT INFORMATION (ONT.) See Item VERTIAL SEAM onstruction No. 55 January 0, 00 Uplift - lass 90 and 60 (See Item No. ) Fire Not Investigated. Metal Roof Deck Panels* No. MSG min thickness coated steel. Panel width 8 in. max., 0 in. min. Rib height -/ in. at female side. Panels continuous over two or more spans. A bead of sealant may be used at panel side joints. METAL SALES MFG ORP - Vertical Seam.. Roof Deck Fasteners* (Panel lips) - One piece assembly, -/ in. wide, -7/8 in. high. One panel clip located at each purlin intersection. METAL SALES MFG ORP - Vertical Seam lip.. Panel Fasteners (Screws) Fasteners used to attach panel clips (Item ) to purlins to be No. 0-6 by in. long plated pancake head No. phillips drive, No. self-drilling point steel screws. Two screws per clip to be used inserted through / in. diam guide holes.. Purlins No. 6 MSG min thickness steel (50,000 psi min yield strength). Spacing for lass 90 to be 8 in. O: For lass 60 to be 60 in. O Refer to General Information Roof Deck onstructions for items not evaluated. *Bearing the UL lassification Mark U L Underwriters Laboratories Inc. LISTED PVS-7

8 UL 580 WIND UPLIFT INFORMATION (ONT.) See Item VERTIAL SEAM onstruction No. 6 January 0, 00 Uplift - lass 90 or 60 Fire Not Investigated (See Item No.). Metal Roof Deck Panels* 0.0 in. thick aluminum or No. MSG min thickness coated steel. Panels 0-/ in. wide, -/ in. high at the ribs. Panels continuous over two or more spans. A bead of sealant may be used at panel side joints. METAL SALES MFG ORP - Vertical Seam. Roof Deck Fasteners* (Panel lips) One piece assembly, -/8 in. wide, -7/8 in. high. One panel clip located at each purlin intersection. Min thickness 0.08 in. (No. 8 MSG). METAL SALES MFG ORP - Vertical Seam lip. Panel Fasteners (Screws) Fasteners used to attach panel clips (Item ) to purlins to be No. 0-6 by in. long, cadmium plated, pancake head, No. phillips drive, No. self-drilling point. Two screws per clip to be used inserted through / in. diam guide hole in clip base.. Purlins No. 6 MSG min thickness steel (50,000 psi min yield strength). Spacing: For aluminum panels: For lass 90 to be 6 in. O.For lass 60 to be 8 in. O.For steel panels: MSG thick to be 60 in. O. MSG thick to be 8 in. O. Refer to General information, Roof Deck onstructions (Roofing Materials and Systems Directory) for items not evaluated. *Bearing the UL lassification Mark U L Underwriters Laboratories Inc. LISTED PVS-8

9 UL 580 WIND UPLIFT INFORMATION (ONT.) a VERTIAL SEAM onstruction No. 0 January 0, 00 Uplift - lass 90 Fire Not Investigated. Metal Roof Deck Panels* No. MSG min thickness coated steel. Panel width 8 in. max., 0 in. min. ribs height -/ in. at female side. Panels continuous over three or more clips with no end laps. A bead of sealant may be used at panel side joints. METAL SALES MFG ORP - Vertical Seam. Roof Deck Fasteners* (Panel lips) One piece assembly, No. MSG min thickness, -/ in. wide, -5/6 in. high. lip spacing to be 8 in. O. lips to interface with Item A (bearing plate). METAL SALES MFG ORP - Vertical Seam lip A. Roof Deck Fasteners* (Bearing Plate) One piece assembly, No. MSG min thickness steel, -/ in. wide, 6 in. long. D. Bearing Plate (Not Shown) - To be used with Vertical Seam lip only (Item ) - Flat plate, -/ in. wide, 6 in. long fabricated from No. MSG coated steel. Two / in. diam guide holes located to accommodate panel clip screw fasteners. (,000 psi min yield strength).. Panel Fasteners - (Screws) Fasteners used to attach panel clips and bearing plates (Items & A) through rigid insulation and optional OSB and/or gypsum board and into light gauge steel deck (Item No. 5) to be No. truss head type with No. Phillips drive, self-drilling steel screws. Two screws per clip to be used, inserted through / in. diam guide holes. Fasteners to penetrate liner panel / in. min.. Foamed Plastic - (Rigid Insulation) Min thickness in., max thickness -/ in. Density to be a min of pcf. A. Oriented Strand Board (OSB) (Optional) - (Not Shown) - Located over foamed plastic (Item ). Max thickness 7/6 in. Note: Bearing plates not required when OSB is used. B. Gypsum Board (Optional) - Max thickness 5/8 in. Located over liner panel (Item 5). 5. Liner Panel Min thickness No. MSG. oated steel (000 psi) min yield strength min depth -/ in., max pitch 6 in. fabricated to various profiles. 6. Underlayment (Not shown) - One ply of 0 lb roofing felt or one layer of bituminous resin type water proofing membrane. Refer to General information, Roof Deck onstructions (Roofing Materials and Systems Directory) for items not evaluated. *Bearing the UL lassification Mark U L Underwriters Laboratories Inc. LISTED PVS-9

10 UL 580 WIND UPLIFT INFORMATION (ONT.) 7 6 7a a 9 8 VERTIAL SEAM onstruction No. October 6, 00 Uplift - lass 90 Fire Not Investigated. Metal Roof Deck Panels* No. MSG min gauge coated steel. Panel width 8 in. max., 0 in. min. Rib height -/ in. at female side. A bead of sealant may be used at panel side joints. Panels continuous over three or more clips with no end laps. METAL SALES MFG ORP - Vertical Seam. Roof Deck Fasteners* (Panel lips) One piece assembly, No. MSG min thickness, -/ in. wide, -5/6 in. high. lip spacing to be 8 in. O. METAL SALES MFG ORP - Vertical Seam lip. Gypsum Board* (Mineral Board) Min thickness / in. Opposite side edges have a tongue and groove configuration. Butt (end) joints to be staggered and occur over steel deck crests. Wallboard installed perpendicular to steel deck corrugations. LOADMASTER SYSTEMS IN. Vapor Barrier (Optional) Installed on top of metal deck (Item 8) or on top of gypsum wallboard (Item ). Minimum 6 mil plastic sheet. 5. Joint Tape (Not Shown) All wallboard joints shall be taped with.5 in. wide joint tape supplied by the manufacturer. 6. Foamed Plastic - (Rigid Insulation) (Optional) - Expanded polystyrene supplied in by 8 ft sheets, min thickness /6 in., min density.0 pcf, or (Rigid Insulation) Polyisocyanurate supplied in by 8 ft sheets or (Rigid Insulation) Phenolic supplied in by 8 ft sheets. All end joints to be staggered with respect to adjoining rows. All joints to be offset from joints in mineral board (Item ). 7. Fasteners For attaching panel clips to steel deck to be two 0.0 in. diam threaded shank Phillips, bugle or trumpet head, self-drilling, self-tapping corrosion resistant coated steel screws supplied by roof deck manufacturer. Screws shall penetrate steel deck min / in. 7A. Fasteners For attaching wallboard to steel deck (Item 8) to be min 0.0 in. diam threaded shank Phillips, bugle or trumpet head, self-drilling, self-tapping, corrosion resistant coated steel screws supplied by the manufacturer. Screws are installed into top corrugations of steel deck through nom by in. corrosion resistant steel roof deck plates, spaced in a pattern as determined by the pitch of the steel deck with the min density of fasteners per by 8 ft sheet (Item ). 8. Steel Deck Fabricated to various profiles, min yield strength,000 psi. Steel deck profile, thickness, support spacing and method of positioning (end and side laps) and fastening deck to supports to be per deck manufacturers requirements for uplift loading. 8A. Deck Fasteners Steel deck panels to be fastened to structural supports and at laps using AR spot welds with weld washers or screw fasteners per deck manufacturer s requirements for uplift loading. 9. Purlins 6 MSG min gauge steel (min yield strength 50,000 PSI) or min Type H open web joists. Refer to General information, Roof Deck onstructions (Roofing Materials and Systems Directory) for items not evaluated. *Bearing the UL lassification Mark U L Underwriters Laboratories Inc. LISTED PVS-0

11 UL 580 WIND UPLIFT INFORMATION (ONT.) 5 5 VERTIAL SEAM onstruction No. December 07, 00 Uplift - lass 90 Fire Not Investigated. Metal Roof Deck Panels* No. MSG min coated steel. Panel width 8 in. max., 0 in. min. Rib height -/ in. at female side. Panels continuous over three or more clips with no endlaps. A bead of sealant may be used at panel side joints. METAL SALES MFG ORP - Vertical Seam. Roof Deck Fasteners*(Panel lips) One piece assembly, -/ in. wide, -7/8 in. high. Min thickness No. 8 MSG. lips spaced 6 in. O, max, fastened to plywood deck. METAL SALES MFG ORP - Vertical Seam lip. Fasteners (Screws) Fasteners used to attach panel clips (Item ) to plywood to be No. 0- by in. long pancake head, No. Phillips drive, A-point, coated steel screw. Min two fasteners per clip to be used.. Underlayment Underlayment used over plywood deck to be Type 5 or 0 organic felt. Sides overlapped min in., end laps per manufacturer s instructions. Felt nailed to plywood deck with -/ in. long steel cap nails, located per manufacturer s instructions. Nail spacing to be max in. O at the side lap and max in. O in interior rows.as An Alternate A self-adhering modified bitumen water proofing membrane may be used, installed per manufacturer s instructions. Note - when alternate is used the plywood joints need not be sealed. 5. Plywood Decking Plywood decking to be graded per PS8 specifications, 9/ in. thick, exposure, APA Rated Sheathing (/0) square edged. Butt ends not blocked. All butt and side joints to be sealed with a one part urethane caulk sealant applied with a caulking gun and feathered outward from the joint. (Note exception under Item No., Alternate.) 6. Supports (Not Shown)-Spaced max of in. O. Any of the following types may be used to support the plywood decking: a) Nom by 6 in., No. grade or better S-P-F, Hemlock Fir, Douglas Fir or Southern Yellow Pine or equivalent. b) Wood trusses with a nom by in. upper chord of the same grade as item a. c) No. MSG min cold formed coated steel (min yield to be,000 psi). 7. Plywood Fasteners (Not Shown)-Fasteners used to attach the plywood deck to the supports to be as follows: a) For plywood-to-wood supports No. 8-8 by -7/8 in. long bugle-head steel screws with a No. Phillips drive, a Hi-Low thread pattern and an S-Point. b) As an alternate to Item a, 8d common nails may be used. c) For plywood-to-steel supports for a steel thickness less than No. 0 MSG No. 7-9 by -/ in. long bugle-head steel screws with a No. Phillips head drive Hi-Low threads and an S-Point. For a steel thickness greater than No. 0 MSG to No. 6 MSG, No. 6-0 by -/ in. long bugle-head steel screws with a No. Phillips drive and a S (TEKS/)supR point. Spacing: Fastener spacing for all fastener types to be 6 in. O at the plywood edges and in. O in the interior. Refer to General information, Roof Deck onstruction (Building Materials Directory) for items not evaluated. *Bearing the UL lassification Mark U L Underwriters Laboratories Inc. LISTED PVS-

12 UL 580 WIND UPLIFT INFORMATION (ONT.) 6 5 " Maximum VERTIAL SEAM onstruction No. 6 February 7, 00 Uplift - lass 90 Fire Not Investigated. Metal Roof Deck Panels* No. MSG min coated steel. Max panel width 8 in., rib height -/ in. Panels continuous over two or more spans. Endlap for panels to be overlapped 6 in. A bead of sealant may be used at panel ends and side joints. METAL SALES MFG ORP - Vertical Seam. Roof Deck Fasteners* - (Panel lips) One piece assembly, -/ in. wide by -7/8 in high. lip spacing to be 8 in. O. METAL SALES MFG ORP - Vertical Seam lip. Fasteners - (Screws) Screws used to attach the panel clips to Substructure (Item ) to be No. 0 by in long Pancake head wood screws with a No. Phillips head or 0x in., / in. Hex Head Woodgrip. Two screws per clip. Screws used to attach Substructure (Item ) to wood trusses or joists (Item 6) to be No. 8 by in. Bugle head screws. As an optional fastener, -/ in. long 8d common deformed shank nails may be used. Fasteners used at endlaps to be x in. Type AB or 0x in. woodgrip. When light gauge structural steel joists are used, screws to be No. by -5/8 in. long with a Phillips head. Spacing of screws to be 6 in. O at plywood or OSB ends and in. O at interior joists.. Substructure (Plywood or OSB) Plywood decking or oriented strand board (OSB) to be a nom 5/8 in. thick, exposure sheathing span -D, 0/0 plywood. (All butt joints to be sealed against leakage by using tape and/or caulking). In lieu of plywood, in. tongue and groove decking may be used. 5. Moisture Barrier - (Optional) Any suitable membrane to protect Substructure (Item ). 6. Joists Joists, spaced at ft, 0 in. O max (when tongue and groove decking is used, joist spacing may be 0 in. O max), may be one of the following: A. Nom by 6 in. wood joists, No. or better. B. Nom by in wood when used on a top chord of a wood truss, No. or better.. Light gauge structural steel framing with the member against the plywood to be a min No. MSG coated steel. Refer to General Information, Roof Deck onstructions, for Items Not Evaluated. *Bearing the UL lassification Mark U L Underwriters Laboratories Inc. LISTED PVS-

13 UL FIRE RESISTANE RATINGS Metal Roof Deck Panels Metal Sales Manufacturing orporation has obtained fire resistance ratings for various products conducted according to test criteria set forth by 'Underwriters Laboratories' "Standard Fire Tests of Building onstruction and Material" (ANSI/UL 6). This test procedure is identical to ASTM E-9 and NFPA 5. The fire resistance rating is for the total assembly and not just the external metal panel. Ratings are expressed in hours and vary depending upon the assemblies. In general, the test criteria is to evaluate the assembly's ability to continue to support the superimposed loads and resist the passage of flame, high temperatures, or hot gases which will ignite combustible materials. The test assemblies are identified by an alpha-numeric design number. For detail information on specific assemblies and hourly ratings see UL Fire Resistance Directory. METAL SALES MFG ORP R9697 Mechanically attached metal roof panels - Type Vertical Seam secured by steel anchor clips. Anchor clips are attached to a hat shaped member* (minimum depth in.) or a bearing plate**. For use in Design Nos. P, P5, P7, P0, P7, P508, P50, P5, P70, P7, P7, P7, P75, P77, P70, P7, P7, P7, P76, P7, P7, P76, P80, P8, P85, P88, P89, P8, P8, P8. *Hat shaped member to be a minimum of 6 gauge. The member will be fastened through the roof insulation to the steel roof deck with min. No. self-drilling and/or self-tapping fasteners. Spacing to be determined by the structural loading requirements. In addition any compressible UL lassified glass fiber blanket insulation with or without a vapor retarder facing may be used between the specified roof insulation and the metal roof panels. **Bearing plate to be a minimum of 6 gauge. Member will be fastened through the roof insulation to the steel deck with min. No. self-drilling and/or self-tapping fasteners. See the UL Fire Resistance Directory for explanation of each design number listed above. U L Underwriters Laboratories Inc. LISTED PVS-

14 SETION PROPERTIES AND LOAD TABLES Factory Applied Sealant /" ",6", or 8" overage GAUGE WIDT H (in) YEILD KSI VERTIAL SEAM SETION PROPERTIES WEIGHT PSF Ixx in /f t.. T OP IN OMPRESSION B OTTOM IN OMPRESSIO N " " " Sxx in /f t Ma (k-in) Ixx in /f t Sxx in /f t Ma (k-in) ALLOWABLE UNIFORM LIVE LOADS PSF... or more- Equal Spans Inward (Gravity / Deflection) Load.. Outward Uplift (Stress) Load. GA. Width Ksi Theoretical section properties have been calculated per AISI 996. Specifications for the design of cold formed steel members. Ixx and Sxx are effective section proper ties for deflection and bending.. Tabulated gravity loads are allowable loads calculated in accordance with AISI 996 specifications considering, bending, shear, and combine stresses. (ombined bending and web crippling is omitted per AISI section.5). Gravity Load considers worst of and multiple equal span condition. Panel weight has not been accounted for in gravity load tables. Allowable loads do not address web crippling requirement or fastener/support connection.. Allowable wind uplift loads have been increased by /% and are based on AISI 996 specifications for the Design of old Formed Steel Members. Note: During uplift or suction condition, panel flat will deflect due to upward load changing shape and reducing these loads. ontact Metal Sales Technical Services for ASTM E-59 uplift design loads.. Deflection consideration is limited by a maximum deflection ratio of L/80 of span. PVS-

15 DESIGN / INSTALLATION ONSIDERATIONS FASTENER INSTALLATION TEHNIQUE Recommended Tool Type - Use depth locating nose or adjustable clutch on screw gun to prevent overdrilling and strip out. Do not use impact tools or runners. Seating the washer - Apply sufficient torque to seat the washer - do not overdrive the fastener. ORRET Sealing material slightly visible at edge of metal washer. Assembly is watertight. TOO LOOSE Sealing material is not visible; not enough compression to seal properly. TOO TIGHT Metal washer deformed; sealing material pressed beyond washer edge. WOODSREW SELF DRILLER To prevent wobbling - Make sure fastener head is completely engaged in the socket. If the head does not go all the way in the socket - tap the magnet deeper into the socket to allow full head engagement. Metal chips will build up from drilling and should be removed from time to time. Protect drill point - Push only hard enough on the screw gun to engage clutch. This prevents excess friction and burn out of the drill point. orrect pressure will allow screw to drill and tap without binding. Drilling through sheet and insulation - Ease up on pressure when drilling through insulation to avoid striking the purlin or girt with the point - apply more pressure after drill point contacts purlin or girt. Drilling through purlin overlaps - Drilling through lapped purlins requires extra care. Excessive voids between purlins sometimes damages drill points and two self-drillers might be necessary to complete the operation. It is sometimes advantageous to predrill. ONDITION OF SUBSTRUTURE Whether over solid substrate or open structural framing, panel distortion may occur if not applied over properly aligned and uniform substructure. The installer should check the roof deck for squareness before installing Vertical Seam panels. Several methods can be used to verify squareness of the structure for proper installation of the panels. METHOD "A" - One method for checking the roof for squareness is to measure diagonally across one slope of the roof from similar points at the ridge and eave and obtain the same dimension. METHOD "B" - The --5 triangle system may also be used. To use this system measure a point from the corner along the edge of the roof at a module of three (). Measure a point from the same corner along another edge at a module of four (). Then by measuring diagonally between the two points established, the dimension should be exactly a module of five (5) to have a square corner. Multiple uses of this system may be required to determine building squareness. If the endwall cannot be made square, the roof system cannot be installed as shown in these instructions. Method A Method B PVS-5

16 DESIGN / INSTALLATION ONSIDERATIONS (ONT) VENTILATION Proper design and installation of vapor barriers and ventilation systems are important to prevent condensation and the resulting problems of moisture damage and loss of insulation efficiency. ondensation occurs when moisture laden air comes in contact with a surface temperature equal to or below the dew point of the air. This phenomenon creates problems that are not unique with metal buildings; these problems are common to all types of construction. The underside of the metal roof on a typical metal building (no attic) should be protected from condensation by insulating with a faced insulation. This should reduce the potential of condensation forming on the underside of the panels. On buildings that have an attic space or are being retrofitted with a metal roofing system, vents should be placed at both the eave and peak of the roof in order to prevent a buildup of moisture (humidity) in the attic space. Vent Vent Insulation Vent at Wall Typical Metal Building (No Attic) Vent at Eave Building with Attic or Retrofitted INSULATION Insulation is recommended on all applications to act as a sound barrier, prevent condensation, and increase insulating value of the roof or ceiling system. Typically, panels are installed over solid substrate but can be installed over open framing or metal decking (shown below) with many different types of insulation. Blanket, rigid, and reflective insulation are just a few. Maximum thickness for blanket insulation is three inches. Please contact your insulation supplier for specific recommendations on type of insulation, vapor barriers, and installation procedures. Vertical Seam lip Blanket Insulation Vertical Seam panel Rigid Insulation /" Maximum (Per UL Listing) Metal Decking Bearing Plate AUTION Use extreme care when working next to insulation. The insulation will provide a false sense of security by hiding the view of the ground below the insulation. PVS-6

17 DESIGN / INSTALLATION ONSIDERATIONS (ONT) SYSTEM EXPANSION / ONTRATION Steel roofing panels are subject to dimensional changes after installation due to exposure to varying temperatures. The greatest influence is solar energy. Steel roofing absorbs various amounts of heat depending upon color, finish, angle of exposure, and time of exposure. The relationship of ambient temperature to building structural temperature must be considered when designing a Vertical Seam roof system. The floating clips for the Vertical Seam panels are designed for expansion and contraction of the panels in the longitudinal direction. Lateral expansion and contraction is accommodated by the configuration of the panel cross section and causes negligible panel movement. When the total length of panel run exceeds the capability of the clips to accommodate the thermal movement, expansion joints must be designed into the structure. SELETION OF SYSTEM OMPONENTS Vertical Seam panel clips - lips are placed along the male leg of each panel prior to installing adjacent panels. Design wind uplift must be considered for proper clip spacing. Vertical Seam lip Vertical Seam UL-90 lip ( fasteners required) The following chart should be used to determine proper fasteners required for clip installation on the selected applications. (See Fastener Selection Guide page 6 for other fasteners available.) APPLIATION LIPS OVER PURLINS (6 GA. MIN) INSTALLATION REQUIREMENTS UL-90 UL-90 UL-90 GAUGE GAUGE **LIP SPAING '-0" O.. '-0" O.. GAUGE 5'-0" O..*** TYPE OF FASTENER #0 X " PANAKE HEAD DRILLER #0 X " PANAKE HEAD DRILLER #0 X " PANAKE HEAD DRILLER # REQ. FASTENERS FASTENERS FASTENERS LIPS OVER 5 /8" WOOD DEK UL-90 UL-90 GAUGE GAUGE '-0" O.. '-0" O.. #0 X " PANAKE HEAD WOOD #0 X " PANAKE HEAD WOOD FASTENERS FASTENERS Max suction pressure of psf LIP OVER RIGID INSULATION / METAL DEK Standard clip Standard clip UL-90 UL-90 GAUGE GAUGE GAUGE GAUGE '-6" O.. '-6" O.. '-0" O.. '-0" O.. #0 X " PANAKE HEAD WOOD #0 X " PANAKE HEAD WOOD DEKFAST #* DEKFAST #* * Length of Dekfast will vary depending on the total thickness of the rigid insulation and metal. ** ontact your local Metal Sales branch representative for more information (see pages and ). *** " Panel Only FASTENER FASTENER FASTENERS FASTENERS Bearing Plate (Flat) PVS-7

18 EAVE DETAIL : SLOPE MINIMUM Vertical Seam Panel Tube Sealant #- x /" Self Driller XL (see below) Double Bead Tape Sealant Eave leat #0-6 x " PHD ("o.c.) AUTION Additional screws may be required for high snow loading and steep slopes. PVS-8 Vertical Seam Fastening Pattern

19 EXTENDED EAVE DETAIL : SLOPE MINIMUM Vertical Seam Panel Tube Sealant #- x /" Self Driller XL (see below) Double Bead Tape Sealant Extended Eave leat #0-6 x " PHD ("o.c.) AUTION Additional screws may be required for high snow loading and steep slopes. Vertical Seam Fastening Pattern VERTIAL SEAM BOX GUTTER DETAIL : SLOPE MINIMUM Vertical Seam Panel Tube Sealant #- x /" Self Driller XL (see below) Double Bead Tape Sealant Universal Gutter/ D.S. Strap ('-0" o.c.) /8" x /6" Pop Rivet (every strap) Box Gutter AUTION In locations where heavy rainfall or severe ice and snow may occur, Metal Sales' standard gutters may not be suitable for use. Vertical Seam Fastening Pattern PVS-9

20 VALLEY DETAIL : SLOPE MINIMUM Vertical Seam Panel Vertical Seam lip Double Bead Tape Sealant #- x /" Self Driller XL (see below) Tube Sealant Valley Valley Plate " Min. L AUTION Additional screws may be required for high snow loading and steep slopes. Vertical Seam Fastening Pattern PVS-0

21 RAKE (ON MODULE) DETAIL Vertical Seam Panel /8" x /6" Pop Rivet ('-0" o.c.) Double Bead Tape Sealant Rake leat Rake #- x /" Self Driller XL ('-0" o.c.) Floating Rake Angle #- x /" Shoulder SD ('-0" o.c.) Rake Angle leat #0-6 x " PHD ('-0" o.c.) PVS-

22 RAKE (OFF MODULE) DETAIL Vertical Seam Panel /8" x /6" Pop Rivet ('-0" o.c.) Double Bead Tape Sealant Rake leat Rake #- x /" Self Driller XL ('-0" o.c.) Floating Rake Angle #- x /" Shoulder SD ('-0" o.c.) Rake Angle leat #0-6 x " PHD ('-0" o.c.) PVS-

23 : SLOPE MINIMUM RAKE PARAPET (ON MODULE) DETAIL Tube Sealant ounter Flashing Fastener (by others) Rakewall #- x /" SD XL ("o.c.) /8 x /6" Pop Rivet ("o.c.) Double Bead Tape Sealant Rake leat #- x /" Shoulder SD ("o.c.) Floating Rake Angle Vertical Seam Panel VERTIAL SEAM : SLOPE MINIMUM RAKE PARAPET (OFF MODULE) DETAIL Tube Sealant ounter Flashing Fastener (by others) Rakewall /8 x /6" Pop Rivet ("o.c.) Double Bead Tape Sealant Rake leat #- x /" SD XL ("o.c.) #- x /" Shoulder SD ("o.c.) Floating Rake Angle Vertical Seam Panel Field bend panel rib up /" PVS-

24 : SLOPE MINIMUM SSR RIDGE/HIP DETAIL Vertical Seam lip Vertical Seam Panel /8" x /6" Pop Rivet (see below) Double Bead Tape Sealant Tube Sealant Vertical Seam Z-losure #0-6 x " PHD ( Per Panel) Double Bead Tape Sealant SSR Ridge/Hip over Back-Up hannel " L Flashing Pop Rivet Z-losure Tape Sealant Gun Grade Sealant PVS-

25 : SLOPE MINIMUM VENTED RIDGE DETAIL Vertical Seam Panel Vertical Seam lip /8" x /6" Pop Rivet ('-0" o.c.) Double Bead Tape Sealant Offset leat #- x 5 /8" Dekfast ('-0" o.c.) Vent Material Tube Sealant #0-6 x " PHD ( per panel) Double Bead Tape Sealant Back-Up hannel Vented Ridge over Vent Drip Note: Refer to PSL-6 for proper ventilation considerations. Flashing Pop Rivet Z-losure Tape Sealant Gun Grade Sealant VERTIAL SEAM : SLOPE MINIMUM AUTION Additional screws may be required for high snow loading and steep slopes. HIGHSIDE PARAPET DETAIL Tube Sealant Fastener (by others) ounter Flashing Pitch Break Back-Up hannel #0-6 x " PHD ( per panel) Tube Sealant Double Bead Tape Sealant /8" x /6" Pop Rivet (see below) Vertical Seam Z-losure Vertical Seam Panel Flashing Pop Rivet Z-losure Tape Sealant Gun Grade Sealant PVS-5

26 NOTES PVS-6

IMAGE II. Panel Information. Detail Conditions. Flashing Profiles. Accessory Profiles. Testing Information. Design/Installation Considerations PIM-1

IMAGE II. Panel Information. Detail Conditions. Flashing Profiles. Accessory Profiles. Testing Information. Design/Installation Considerations PIM-1 Table of ontents Product Page No. Product Page No. Panel Information Profiles... PIM-2 Panel Overview...PIM-2 Flashing Profiles Eave...PIM-3 Extended Eave...PIM-3 leat...pim-3 Offset leat...pim-3 5K Gutter...PIM-3

More information

TABLE OF CONTENTS IMAGE II. Detail Conditions. Panel Information. Flashing Profiles

TABLE OF CONTENTS IMAGE II. Detail Conditions. Panel Information. Flashing Profiles TABLE OF ONTENTS Product Page No. Product Page No. Panel Information Profi les...pim-2 Panel Overview...PIM-2 Flashing Profiles Eave...PIM-3 Extended Eave...PIM-3 leat...pim-3 Offset leat...pim-3 5K Gutter...PIM-3

More information

STILE. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles. Testing Information

STILE. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles. Testing Information Table of ontents Product Page No. Product Page No. Panel Information Profile...PST-2 Panel Overview...PST-2 Flashing Profiles Eave...PST- Extended Eave...PST- leat...pst- Stile Starter...PST- Box Gutter...PST-

More information

CLIP-LOC. Panel Information. Detail Conditions. Flashing Profiles. Notes. Accessory Profiles. Testing Information. Design/Installation Considerations

CLIP-LOC. Panel Information. Detail Conditions. Flashing Profiles. Notes. Accessory Profiles. Testing Information. Design/Installation Considerations LIP-LO Table of ontents Product Page No. Product Page No. Panel Information lip-loc Panel Profile... PL-2 Panel Overview... PL-2 Flashing Profiles Eave... PL- leat... PL- Box Gutter... PL- Box Gutter End...

More information

Detail Conditions. Panel Information. Flashing Profiles. Notes. Accessory Profiles. Testing Information. Design/Installation Considerations PEF-1

Detail Conditions. Panel Information. Flashing Profiles. Notes. Accessory Profiles. Testing Information. Design/Installation Considerations PEF-1 Table of ontents Product Page No. Product Page No. Panel Information T3 Panel Profiles... PEF-2 T3 Panel Overview... PEF-2 T6- Panel Profiles... PEF-3 T6- Panel Overview... PEF-3 T- Panel Profiles... PEF-4

More information

Prior to ordering and installing materials, all dimensions should be verified by field measurements.

Prior to ordering and installing materials, all dimensions should be verified by field measurements. Important Information The application and detail drawings in this manual are strictly for illustration purposes and may not be applicable to all building designs or product installations. All projects

More information

* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request.

* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request. is a concealed fastener architectural standing seam roof panel. The panels are easily installed over decking, utilizing metal clips. panels are ideally suited for decorative mansard, fascia and roofs.

More information

UNA-CLAD Metal Roof Systems Code Approval Guide

UNA-CLAD Metal Roof Systems Code Approval Guide UNA-CLAD Metal Roof Systems Code Approval Guide You must verify the included assemblies in the charts below with the associated Firm s (UL, FM, etc). t all of the information included in the RoofNav assemblies

More information

1.5 snap lock sl 150

1.5 snap lock sl 150 1.5 snap lock sl 150 Strip Width Base Material Thickness Min Tensible Min Yield Coatings 12.00 to 24 Steel.0128 to.027 in 52 - ksi 50 - ski Painted / Galvalume UL CONSTRUCTION NUMBERS: TGKX301, tgkx342a,

More information

ML200 Panel Technical Data Guide

ML200 Panel Technical Data Guide Description ML200 is a mechanical seamed standing seam roofing panel used on low to steep sloped commercial applications. The panel is factory formed in continuous lengths up to 60-0 long. Attachment to

More information

SEAM-LOC 24. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles

SEAM-LOC 24. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles Table of ontents Product Page No. Product Page No. Panel Information Seam-Loc 24 Panel Profile...PSL-2 Panel Overview...PSL-2 Flashing Profiles Seam-Loc 24 Sculptured Eave...PSL- Seam-Loc 24 Sculptured

More information

SSL-175. Specifications

SSL-175. Specifications SSL-175 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Preformed Metal Roofing PART 1: GENERAL 1.01 SECTION INCLUDES

More information

TYPICAL ROOF CONDITION LAYOUT

TYPICAL ROOF CONDITION LAYOUT FIXED POINTS TYPICAL ROOF CONDITION LAYOUT 15 17 9 16 29 12 14 11 3 7 35 20 6 23 30 31 24 13 18 Typical Roof Condition Layout... 1 Low Eave Isometric View - Fixed/ Floating... 2 Low Eave Section - Fixed/

More information

DL-200. Specifications

DL-200. Specifications DL-200 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Structural Preformed Metal Roofing PART 1: GENERAL 1.01

More information

EVERSEAM 20 APPLICATION GUIDE

EVERSEAM 20 APPLICATION GUIDE EVERSEAM 20 APPLICATION GUIDE Panel Overview Our Name Says It All!"#$%#&'()*+,!"#$%#&'(-.( Applications: The EverSeam panel is an architectural panel that is ideal for residential and light commercial

More information

UNA-CLAD Metal Roof Systems

UNA-CLAD Metal Roof Systems UNA-CLAD Metal Roof Systems Underwriters Laboratories (UL) UL Roof Deck Constructions and P Assemblies Factory Mutual Approvals (FM) Table of Contents 1.01 EXTERNAL FIRE RATINGS... 7 Assemblies are updated

More information

SL175 Panel Technical Data Guide

SL175 Panel Technical Data Guide Description SL175 is a integral snap-lock standing seam roofing panel used on commercial and residential applications. The panel is factory formed in continuous lengths up to 60-0 long. Attachment to either

More information

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5 Table of Contents Section Page Notes to Designer/User...................1-2 Map of Typical Roof Conditions..............3 Fastener Placement........................4 Fastener Selection.........................5

More information

SECTION METAL ROOF AND SOFFIT PANELS

SECTION METAL ROOF AND SOFFIT PANELS Metal Panel Systems, Inc. 11506 Reading Road Cincinnati, Ohio 45241-2512 Telephone: 800-554-6126 or 513-554-6120 Fax: 513-554-6121 www.metalpanelsystems.com info@metalpanelsystems.com Specifications for

More information

Roofing Installation Manual: Concealed Fastener Panels Material Data, Trim Details, and Step-by-Step Instructions

Roofing Installation Manual: Concealed Fastener Panels Material Data, Trim Details, and Step-by-Step Instructions Roofing Installation Manual: Concealed Fastener Panels Material Data, Trim Details, and Step-by-Step Instructions 1974 Livengood Ave Fairbanks, AK 99701 907-479-6002 allsteel.info@gmail.com Roof Installation

More information

IMPORTANT INFORMATION

IMPORTANT INFORMATION IMPORTANT INFORMATION The application and detail drawings in this manual are strictly for illustration purposes and may not be applicable to all building designs or product installations. All projects

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used

More information

a division of NCI Standing Seam Roof Systems

a division of NCI Standing Seam Roof Systems a division of NCI Standing Seam Roof Systems Building Benefits You Can Expect From A&S Materials Standing Seam roof panels weigh a relatively modest 11/2 pounds per square foot. When long life is required

More information

TRIAD CORRUGATED METAL, INC.

TRIAD CORRUGATED METAL, INC. TRIAD CORRUGATED METAL, INC. C O M M E R C I A L R E S I D E N T I A L A G R I C U L T U R A L Snap Loc Panel Guide Snap Loc metal panels are a perfect fit for residential, architectural and commercial

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification

More information

SHURLOC 150 STANDARD DETAILS

SHURLOC 150 STANDARD DETAILS OVER WOOD DECK STANDARD DETAILS Austin - Headquarters/Sales Office 830 Sagebrush Drive Austin, TX 78758 (512) 452-1515 (800) 428-7412 Fax (512) 833-7499 www.ctmrs.com email: info@ctmrs.com Seguin - Plant/Sales

More information

PBR & PBU PANELS. Technical/Installation Information

PBR & PBU PANELS. Technical/Installation Information PBR & PBU PANELS Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE PANEL S. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS A MINIMUM

More information

T-Armor Install Guide

T-Armor Install Guide T-Armor Install Guide The application and detail drawings in this manual are strictly for illustration purposes and may not be applicable to all building designs or product installations. All projects

More information

5V Crimp DESIGN/INSTALLATION INFORMATION

5V Crimp DESIGN/INSTALLATION INFORMATION 5V Crimp DESIGN/INSTALLATION INFORMATION IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE SYSTEM. METAL DEPOTS DETAILS MUST BE FOLLOWED AS A MINIMUM TO INSURE APPROPRIATE

More information

IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE WEATHER GUARD PANEL.

IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE WEATHER GUARD PANEL. IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE WEATHER GUARD PANEL. IF THERE IS A CONFLICT BETWEEN PROJECT ERECTION DRAWINGS PROVIDED OR APPROVED BY WHIRLWIND BUILDING

More information

PBR & PBU PANELS. Technical/Installation Information

PBR & PBU PANELS. Technical/Installation Information PBR & PBU PANELS Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE Retro-R PANELS. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS

More information

SNAP-CLAD. Technical Information and Flashing Details. /

SNAP-CLAD. Technical Information and Flashing Details.  / SNAP-CLAD Technical Information and Flashing Details Product Information: PAGE 3 SNAP-CLAD Spec. Sheet PAGES 4-13 UL List Cards - UL Construction Numbers 261, 254, 255, 263, 343, 303, 508, 508A, 614, 790

More information

Western States 7/8 Corrugated

Western States 7/8 Corrugated Western States 7/8 Corrugated Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer / Installers..1 Fastener Placement and Selection.2-3 Key

More information

TRIAD CORRUGATED METAL, INC.

TRIAD CORRUGATED METAL, INC. TRIAD CORRUGATED METAL, INC. COMMERCIAL RESIDENTIAL AGRICULTURAL MS-216 MS-218 Panel Guide This guide describes the design and performance characteristics of the MS-216 and MS-218 Roof panel system. The

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC. 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1143 Reissued 04/2017 This report is subject to renewal 04/2018. DIVISION: 07 00 00 THERMAL

More information

Architectural Wall Products Guide Specifications

Architectural Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is

More information

WESTERN RIB. Installation, Flashings & Shop Drawing Detail Guide.

WESTERN RIB. Installation, Flashings & Shop Drawing Detail Guide. WESTERN RIB Installation, Flashings & Shop Drawing Detail Guide 901 W. Watkins Street Phoenix, AZ 85007 Phone: (877) 787-5467 (855) 426-7836 Email: sales@cortenroofing.com sales@metalforroofing.com For

More information

VP ROOF SYSTEMS SSR ROOF SYSTEM. WEATHERTIGHT PERFORMANCE FOR low-slope ROOF APPLICATIONS

VP ROOF SYSTEMS SSR ROOF SYSTEM. WEATHERTIGHT PERFORMANCE FOR low-slope ROOF APPLICATIONS VP ROOF SYSTEMS style SSR ROOF SYSTEM INTERLOCKING PANELS provide LONG TERM WEATHERTIGHT PERFORMANCE FOR low-slope ROOF APPLICATIONS 3 high ribs and 24 panel width allow for positive water drainage Available

More information

900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900

900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900 CS-PJ-01-900 CS-DS-01-900 CS-PJ-02-900 CS-EL-01-900 CS-EL-02-900 CS-EL-03-900 CS-EL-04-900 CS-RD-01-900 CS-RD-02-900 CS-RD-03-900 CS-EV-01A-900 CS-EV-01B-900 CS-EV-02A-900 CS-EV-02B-900 CS-EV-03A-900 CS-EV-03B-900

More information

CS-100 Guide Specifications

CS-100 Guide Specifications MANUFACTURER CUSTOM-BILT METALS 1333 Corporate Drive, Suite 103 Irving, Texas 75038-2520 (800) 826-7813 or info@custombiltmetals.com www.custombiltmetals.com CS-100 Guide Specifications This Guide Specification

More information

R PANEL / PBR PANEL. Installation, Flashings & Shop Drawing Detail Guide.

R PANEL / PBR PANEL. Installation, Flashings & Shop Drawing Detail Guide. R PANEL / PBR PANEL Installation, Flashings & Shop Drawing Detail Guide 901 W. Watkins Street Phoenix, AZ 85007 Phone: (877) 787-5467 (855) 426-7836 Email: sales@cortenroofing.com sales@metalforroofing.com

More information

RESIDENTIAL LIGHT GAUGE APPLICATION GUIDE

RESIDENTIAL LIGHT GAUGE APPLICATION GUIDE Our Name Says It All RESIDENTIAL LIGHT GAUGE APPLICATION GUIDE Lebanon, PA 888.339.0059 Bridgton, ME 800.677.2060 Howe, IN 866.562.3782 www.everlastroofing.com Residential Light Gauge Table of Contents

More information

Stile. Spanish Tile Installation Guide

Stile. Spanish Tile Installation Guide Stile Spanish Tile Installation Guide IMPORTANT INFORMATION THE APPLICATION AND DETAIL DRAWINGS IN THIS MANUAL ARE STRICTLY FOR ILLUSTRATION PURPOSES AND MAY NOT BE APPLICABLE TO ALL BUILDING DESIGNS OR

More information

Through-Fastener Panel UL Listing documentation

Through-Fastener Panel UL Listing documentation Through-Fastener Panel UL Listing documentation Class-4 Impact Rating Class-90 Fire Rating Tensile Strength: Grade 80/E Coil Thickness Range for 29 ga.: 0.0142 0.015 Coil Thickness Range for 26 ga.: 0.0182

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV

More information

EVALUATION REPORT OF CENTRAL STATES MANUFACTURING, INC. 'CENTRAL-LOC PANEL' FLORIDA BUILDING CODE 5TH EDITION (2014) FLORIDA PRODUCT APPROVAL

EVALUATION REPORT OF CENTRAL STATES MANUFACTURING, INC. 'CENTRAL-LOC PANEL' FLORIDA BUILDING CODE 5TH EDITION (2014) FLORIDA PRODUCT APPROVAL - EVALUATION REPORT OF CENTRAL STATES MANUFACTURING, INC. 'CENTRAL-LOC PANEL' FLORIDA BUILDING CODE 5TH EDITION (2014) FLORIDA PRODUCT APPROVAL FL 14016.2-R2 STRUCTURAL COMPONENTS ROOF DECK Prepared For:

More information

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System 0 00/NGC NATIONAL GYPSUM COMPANY -Hour Wall System The -Hour is a -hour fire wall consisting of in. (0. mm) light-gauge steel H-Studs that secure two layers of in. (. mm) shaftliner panels friction-fit

More information

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590

More information

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

Guide Specifications ADP Series SECTION SHEET METAL ROOFING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Sheet metal roofing panels, metal trim, accessories, fasteners, closures, and sealants. [Specifier Note: Edit paragraph below to suit project requirements.]

More information

PRE-ENGINEERED METAL BUILDING SYSTEM

PRE-ENGINEERED METAL BUILDING SYSTEM PRE-ENGINEERED METAL BUILDING SYSTEM PART 1 GENERAL 1.1 SUMMARY A. The building shall include all primary and secondary structural framing members, connection bolts, roof and wall covering, flashing, gutter,

More information

SECTION METAL ROOF PANELS

SECTION METAL ROOF PANELS SECTION 07 41 13 PART 1 GENERAL 1.1 SECTION INCLUDES A. Standing-seam roof panels. B. Metal roofing accessories. 1.2 RELATED SECTIONS A. Section 07 62 00 - Sheet Metal Flashing. B. Section 07 72 00 - Roof

More information

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590

More information

Table of Contents. 3. Standing Seam Panels

Table of Contents. 3. Standing Seam Panels Table of Contents 895 North Parkway 3. Standing Seam Panels Standing Seam Panels Table of Contents... PS1-2 Double-Lok... PS3-8 Ultra-Dek... PS9-14 BattenLok HS... PS15-18 Curved BattenLok HS... PS19-20

More information

Architectural Roof Products Guide Specifications

Architectural Roof Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification

More information

Architectural Roof Products Guide Specifications

Architectural Roof Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification

More information

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 NOTICE OF ACCEPTANCE

More information

SECTION PRE-ENGINEERED WOOD POST FRAME BUILDING SYSTEM. B. Products Supplied But Not Installed Under This Section:

SECTION PRE-ENGINEERED WOOD POST FRAME BUILDING SYSTEM. B. Products Supplied But Not Installed Under This Section: SECTION 13125 FRAME BUILDING SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Primary and secondary wood structural framing systems, roofing and wall covering systems, roof and wall insulation,

More information

SECTION CEMENTITIOUS WOOD FIBER DECKS

SECTION CEMENTITIOUS WOOD FIBER DECKS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 03 51 13 CEMENTITIOUS WOOD FIBER DECKS SPEC WRITE NOTES: 1. Delete between // // if not applicable to project. 2. Also delete any other item or paragraph not applicable

More information

SECTION STANDING SEAM METAL ROOFING

SECTION STANDING SEAM METAL ROOFING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 41 13 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Use for roofing sloped 1 in 4 (3 in/ft) or greater. 3. Delete between // // if not applicable

More information

Duct Wrap Flexible Wraps

Duct Wrap Flexible Wraps Design No. 3MU/ 60-01 December 23, 2010 VENTILATION DUCT PROTECTION 3M Company 3M Fire Barrier Duct Wraps: 615 and 615+ 3M Fire Barrier Sealants: Water-Tight 1000-NS Silicone, Water-Tight 1003-SL Silicone

More information

ESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years.

ESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years. ICC-ES Evaluation Report ESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance 1 of 6 5/8/2012 4:19 PM TGIK.R9734 Roofing Systems, Uplift Resistance Page Bottom Roofing Systems, Uplift Resistance See General Information for Roofing Systems, Uplift Resistance KELLY CO-2001 INC 325

More information

1.5 mechanical lock ml 150

1.5 mechanical lock ml 150 1.5 mechanical lock ml 150 Strip Width Base Material Thickness Min Tensible Min Yield Coatings Max 16 Steel.0225 to.0336 in 52 - ksi 50 - ski Painted / Galvalume UL CONSTRUCTION NUMBERS: TGKX554 The Mechanical

More information

NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS

NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS Nucor VR16 II Vertical Rib Standing Seam Roof System...2 Nucor VR16 II Property and Span Tables...3 Standard Details...5 ED3010PE - Gutter...5

More information

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO SECTION 07220 - ROOF INSULATION PART 1 - GENERAL 1.01 DESCRIPTION A. Work included: The Roofing Contractor will provide all polyisocyanurate insulation and high density wood fiber roof insulation (tapered

More information

ABSeam Panel Overview and Installation Instructions

ABSeam Panel Overview and Installation Instructions 82 Garden Spot Road Ephrata, PA 17522 717-445-6885 35 Ridge Road Newville, PA 17241 717-776-5951 ABSeam Panel Overview and Installation Instructions Applications: The ABSeam panel is an architectural panel

More information

The better way to build TM. Installation Manual NAILBASE PANELS

The better way to build TM. Installation Manual NAILBASE PANELS The better way to build TM Installation Manual PANELS November 2018 SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................

More information

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION. SECTION 074213 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting

More information

Table of Contents. 3. Exposed Fastener Panels

Table of Contents. 3. Exposed Fastener Panels Table of Contents 895 North Parkway 3. Exposed Fastener Panels Exposed Fastener Panels Table of Contents... PE1-2 PBR... PE3-4 PBA... PE5-6 AVP... PE7-8 PBU... PE9-10 PBC... PE11-12 PBD... PE13-14 7.2...

More information

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System -Hour Wall System The -hour Wall System is a -hour fire wall consisting of two layers of in. (. mm) shaftliner panels friction-fit between in. (0. mm) light-gauge steel H-Studs and a layer of /" Fire-Shield

More information

1.5 mechanical lock ml 150

1.5 mechanical lock ml 150 1.5 mechanical lock ml 150 Strip Width Base Material Thickness Min Tensible Min Yield Coatings Max 16 Steel.0225 to.0336 in 52 - ksi 50 - ski Painted / Galvalume UL CONSTRUCTION NUMBERS: TGKX554 The Mechanical

More information

NRDCA GUIDELINE FOR APPLICATION of CEMENTITIOUS WOOD FIBER ROOF DECK SYSTEMS

NRDCA GUIDELINE FOR APPLICATION of CEMENTITIOUS WOOD FIBER ROOF DECK SYSTEMS NRDCA 600 - GUIDELINE FOR APPLICATION of CEMENTITIOUS WOOD FIBER ROOF DECK SYSTEMS The National Roof Deck Contractors Association (NRDCA) has prepared this document to provide, customers and installers,

More information

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590

More information

Light-Metal Roof Edge, Raised

Light-Metal Roof Edge, Raised NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED

More information

2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (RAS)

2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (RAS) ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES 1.. 3. Scope

More information

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079) WET FILM ± 7.5 ± 5 Design No. CEJ 27 P (HI/JS 20-05) Table. CONCRETE FLOOR ASSEMBLY: Max. two-hour rated concrete floor assembly made from either lightweight or normal weight concrete with a density of 00-50 pcf, with a

More information

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance UL TGIK.R9734 Roofing Syst. Uplift Resistance * www.2001company.com * 1.800.537.7663 * Page 1 of 6 Page 1 of 6 Page Bottom TGIK.R9734 Roofing Systems, Uplift Resistance Roofing Systems, Uplift Resistance

More information

Residential Pricing Guide

Residential Pricing Guide Guide TABLE OF CONTENTS Panels 5V Crimp Slimline 2 4 Accessories Flat Sheets Coils V-Groove Soffit Ridge Caps Roof Jacks Touch-up Paint Insulation Slimline Rib Cover Closure Strips Tube Sealant 6 6 7

More information

2120 SW Poma Drive; Palm City, Florida Phone Fax

2120 SW Poma Drive; Palm City, Florida Phone Fax 2120 SW Poma Drive; Palm City, Florida 34990 772-223-4055 Phone 772-781-7492 Fax www.sunlastmetal.com sales@sunlastmetal.com IMPORTANT NOTICE READ THIS MANUAL COMPLETELY BEFORE BEGINNING INSTALLATION OF

More information

A. Metal Building System Description: Rigid modular, with interior columns with expandable endwall.

A. Metal Building System Description: Rigid modular, with interior columns with expandable endwall. SECTION 13125 - METAL BUILDING SYSTEMS PART 1 - GENERAL 1.1 SECTION REQUIREMENTS A. Metal Building System Description: Rigid modular, with interior columns with expandable endwall. 1. Eave Height: 13-0

More information

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi STRUCTURAL NOTES MATERIAL STRENGTHS Structural Steel Reinforcing Steel Concrete Masonry Structural Lumber Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel

More information

Engineering Services Program

Engineering Services Program Product Evaluation Engineering Services Program The following product has been evaluated for compliance with the wind loads specified in the International Residential Code (IRC) and the International Building

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 4 6587 (562) 699 0543 www.icc es.org ESR 3152 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

Trusted Tested Tough Kalaeloa Blvd, Kapolei, Hawaii Phone (808) Fax (808) Neighbor Islands (800)

Trusted Tested Tough Kalaeloa Blvd, Kapolei, Hawaii Phone (808) Fax (808) Neighbor Islands (800) MAC 200 STRUCTURAL STANDING SEAM METAL ROOF SYSTEM Trusted Tested Tough 91-104 Kalaeloa Blvd, Kapolei, Hawaii 96707 Phone (808) 682-3000 Fax (808) 682-3636 Neighbor Islands (800) 352-3920 www.kloecknermetals.com

More information

Covering Design Regions

Covering Design Regions Covering Covering Design Regions Roof Covering Roof Covering (SSR) 24 coverage w/ 3 seam height Machine seamed, in-place Attached to roof secondary (purlins, widebay truss purlin or bar joist) w/ a concealed

More information

3' COMMERCIAL RIB PREFORMED METAL SIDING

3' COMMERCIAL RIB PREFORMED METAL SIDING SECTION 07410 3' COMMERCIAL RIB PREFORMED METAL SIDING PART 1 GENERAL 1.01 DESCRIPTION A. Work in this section includes furnishing and installation, preformed steel ribbed siding on vertical portions of

More information

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS I N SULROCK FIRE RATED METAL PANELS GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS 1. GENERAL 1.1. Summary Fire-rated panels as shown on the drawings shall be INSULROCK brand panels as supplied by Green

More information

CONTOUR CORRUGATED PANEL

CONTOUR CORRUGATED PANEL CONTOUR CORRUGATED PANEL Table of Contents SECTION PAGE Designer Notes............................................... 1 Panel Net Coverage / Fasteners.................................... 2 ROOF Details

More information

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS Insulation First Revison October 2016 DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS 1. General Information This Guide describes the use of Kingspan GreenGuard DC14 Drainage

More information

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM SECTION 13 34 21 - STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM PART 1 - GENERAL 1.1 DESCRIPTION A. The structural retrofit roof sub-framing system will provide support for a new metal roofing system constructed

More information

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers. SECTION 05 31 23 - STEEL ROOF DECKING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the contract, including General and Supplementary Conditions and Division 01 - Specification

More information

SECTION ROOF SPECIALTIES

SECTION ROOF SPECIALTIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

TABLE OF CONTENTS PRODUCT CATALOGUE fax OVERVIEW PBR 7.2 LONGSPAN ECONORIB

TABLE OF CONTENTS PRODUCT CATALOGUE fax OVERVIEW PBR 7.2 LONGSPAN ECONORIB PRODUCT CATALOGUE www.metroll.us sales@fontana.metroll.com ph. 909.823.7663 fax 909.693.5153 TABLE OF CONTENTS OVERVIEW PBR Product Overview and Color Charts Panel Information and Trim 7.2 LONGSPAN ECONORIB

More information

Drexel Metals Inc. DMC 5V 26 Gauge min. Face-Fastening Metal Roof System over Plywood

Drexel Metals Inc. DMC 5V 26 Gauge min. Face-Fastening Metal Roof System over Plywood Drexel Metals Inc. DMC 5V 26 Gauge min. Face-Fastening Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed

More information

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses (MPCWT) Design Guide Revised 11/17/2016

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses (MPCWT) Design Guide Revised 11/17/2016 Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses (MPCWT) Design Guide Revised 11/17/2016 SBCA has been the voice of the structural building components industry since 1983,

More information

BXUV.L576 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

BXUV.L576 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263 Page 1 of 7 Page Bottom BXUV.L576 Fire Resistance Ratings - ANSI/UL 263 Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. L576 August 15,

More information

STONE COATED METAL ROOF SHINGLE

STONE COATED METAL ROOF SHINGLE GUIDE SPECIFICATION Manufacturer: A Fletcher Building Company 1230 Railroad Street Corona, CA 92882 951-272-8180 phone 951-272-4476 facsimile www.decra.com SECTION 07313 [07 31 13] STONE COATED METAL ROOF

More information

Central Seam Plus. Central-Loc

Central Seam Plus. Central-Loc Central Seam Plus Central-Loc Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES 3" 3" " or 18" COVERAGE " or 18" COVERAGE Central Seam Plus Field seamed Central-Loc Snaps together

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (0) 3-87 (562) 699-03 www.icc-es.org ESR-23 Reissued 08/2017 This report is subject to renewal 08/2019. DIVISION: 07 00 00 THERMAL

More information