1 FLOOR AREAS LIVING AREA ENTRY PORCH LOGGIA GARAGE 4,202 SQ. FT 239 SQ.FT 457 SQ.FT. 906 SQ. FT PROJECT DATA PROJECT ADDRESS: 1698 Reliez Valley Rd. Lafayette, CA. OCCUPANCY: R3/U CONSTRUCTION TYPE: TYPE V-B APN: STORIES: 1 Story FIRE SPRINKLERS: Yes ZONING: LR-5 SETBACK REQUIREMENTS: Front Sides Rear PROJECT DIRECTORY LEGAL OWNER Roger Sabatte and Sharon Reuff 321 Hartz Ave, Ste 200 Danville, CA CODES IN EFFECT: 2013 California Building Code- CBC 2013 California Residential Code CRC 2013 California Plumbing Code CPC 2013 California Mechanical Code CMC 2013 California Electrical Code CEC 2013 California Referenced Standards Code 2013 California Energy Code 2013 CGBC- California Green Building Standards Code City of Lafayette Municipal Code 3/23/2016 2:06:28 PM ABBREVIATIONS & AND > AT CL CENTERLINE o DIAMETER OR ROUND # POUND OR NUMBER (E) EXISTING A.B. ANCHOR BOLT ABV. ABOVE ACOUS. ACOUSTICAL ADJ. ADJUSTABLE AFF. ABOVE FINISH FLOOR AGGR. AGGREGATE ALUM. ALUMINUM APPROX. APPROXIMATE ARCH. ARCHITECT ASPH. ASPHALT AWN AWNING BD. BOARD BLDG. BUILDING BLK. BLOCK BLK'G BLOCKING BLT. BOLT BM. BEAM BOT. BOTTOM CAB. CABINET CEM. CEMENT CER.. CERAMIC C.G. CORNER GUARD CLG. CEILING CLKG. CAULKING CLO. CLOSET CLR CLEAR C.O. CASED OPENING COL. COLUMN CONC. CONCRETE CONN. CONT. CSMT DBL DEPT. D.F. DET. DIA. DIM. DISP. DL DN. DR. DS. (E) E.J. EL ELEC. ELEV. EMER. ENCL. EQ. EQPT. EXT. F.A. F.D. FDN. F.A. F.B. FG F.C. FIN F.O.C. F.O.W. F.O.S. FRM'G F.S. CONNECTION CONTINUOUS CASEMENT DOUBLE DEPARTMENT DRINKING FOUNTAIN DETAIL DIAMETER DIMENSION DISPENSER DIVIDED LIGHT DOWN DOOR DOWNSPOUT EXISTING EXPANSION JOINT ELEVATION ELECTRICAL ELEVATOR EMERGENCY ENCLOSED EQUAL EQUIPMENT EXTERIOR FIRE ALARM FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FINISH FLOOR FIXED GLASS FINISH GRADE FINISH FACE OF CONCRETE FACE OF WALL FACE OF STUDS FRAMING FULL SIZE FTG. FURR. FUT. GALV. GL GYP. FOOTING FURRING FUTURE GALVANIZED GLASS GYPSUM H.B. HOSE BIBB HDR. HEADER HDWD. HARDWOOD HORIZ. HORIZONTAL HR. HOUR HT. HEIGHT HVAC. HEATING, VENTILATING, AIR CONDITIONING HS HORIZONTAL SLIDER INSL. INSULATION INT. INTERIOR MAX. M.A. MECH. MEMB. MNFR. MFR. MIN.A. MISC. N NUM. N.T.S. MAXIMUM MEDICINE CABINET MECHANICAL MEMBRANE MANUFACTURING MANUFACTURER MINIMUM MISCELLANEOUS NORTH NUMBER NOT TO SCALE O/ OVER O.C. ON CENTER OPN'G. OPENING OPP. OPPOSITE SABATTE RESIDENCE 1698 RELIEZ VALLEY RD. LAFAYETTE, CA. PL PLATE PLAM. PLASTIC LAMINATE PLAS. PLASTER PLYWD. PLYWOOD PLUMB. PLUMBING PL PROPERTY LINE PR. PAIR P.T. POINT PREFAB PREFABRICATED R. RISER RAD. RADIUS REF. REFRIGERATOR REINF REINFORCED REQD. REQUIRED RM. ROOM R.O. ROUGH OPENING RWD. REDWOOD S. SOUTH SCSC SOLID CORE SELF CLOSING SEC. SECTION SQ.FT. SQUARE FEET SHLV. SHELVES SH SINGLE HUNG SHWR. SHOWER SHT. SHEET SIM. SIMILAR STOR. STORAGE STRUCT. STRUCTURAL SUSP. SUSPENDED S.S.D. SEE STRUCTURAL DRAWINGS T.B. T.O.C. TEL T&G TOWEL BAR TOP OF CURB TELEPHONE TONGUE AND GROOVE T.O.P. TOP OF PARAPET T.O.W. TOP OF WALL T.P.D. TOILET PAPER DISPENSE T.V. TELEVISION TYP. TYPICAL U.O.N. UNLESS OTHERWISE NOTED VERT. VERTICAL W. WEST W/ WITH WD. WOOD W.H. WATER HEATER W/O WITHOUT WP WATERPROOF DIFFERED SUBMITTAL VICINITY MAP Reliez Valley Rd SITE CIVIL ENGINEER Humann Company, Inc Brown Ave. Lafayette, CA Phone (925) Fax (925) STRUCTURAL ENGINEER ENERGY COMPLIANCE CONSULTANT (TITLE-24) DRAWING INDEX ARCHITECTURAL 1. A0.1 COVER SHEET 2. C1 (E) TOPOGRAPHICAL SURVEY 3. C2 PRELIMINARY GRADING & DRAINAGE PLAN 4. C3 EXISTING CONSTRAINTS EXHIBIT 5. C4 CONTEXT MAP 6. A2.1 SITE PLAN 7. A2.2 LANDSCAPE PLAN 8. A2.3 STORY POLE PLAN 9. A4.1 FLOOR PLAN 10. A5.1 ARCHITECTURAL ROOF PLAN 11. A6.1 EXTERIOR ELEVATIONS 12. A6.2 EXTERIOR ELEVATIONS 13. A6.3 BUILDING SECTIONS 14. A6.4 SITE SECTIONS Withers Ave Taylor Blvd Withers Ave Pleasant Hill Rd Pleasant Hill Rd ant Hill Rd GENERAL NOTES 1. Prior to construction, owner and /or their representative is responsible for submitting required information to the fire department to determine if fire sprinklers are required for this project. all coordination and associated costs are not the responsibility of the designer. 2. The intent of these drawings is to show all necessary items to complete this structure. Typical details & notes within these drawings apply to similar conditions, unless noted otherwise. All work & construction shall comply with all applicable building codes, regulations, and safety requirements. For items, methods, and/or materials not shown, the minimum requirements of the current California building code, California mechanical code, California plumbing code, California electric code, and all other local state and municipal codes and ordinances shall govern. 3. Steven F. Kubitschek is not responsible for fabrication, erection and/or safety. The contractor shall comply with all safety regulations. 4. The contractor shall hold harmless, indemnify and defend the owner, designer, engineer, and his consultants, and each of their officers and employees from all liability claims, losses, or damages arising or said to arise from the performance of work described herein. 5. While every attempt has been made to avoid mistakes in the preparation of these plans, the maker cannot guarantee against human error, therefore, the dimensions and specifications of these plans shall be verified by the owner/contractor prior to the commencement of construction, and any discrepancies shall be brought to the attention of Steven F. Kubitschek. 6. These plans have been drawn to comply with the clients specifications, and any changes made to them after prints are made shall be done at the clients expense. 7. All work shall be the best of their respective types, and contractors shall be responsible for observance of all state, county, and local building codes. 8. Fire, vandalism, and theft insurance by owner, public liability, and workman's compensation insurance by contractor. 9. The job shall be left broom clean, with windows and fixtures washed, and all debris removed by contractor. 10. The contractor shall give the designer 48 hrs. notice minimum when site observations are necessary. 11. Any and all engineering and survey work required in connection with this project shall be by separate contract between owner/contractor and the engineer of his choice. 12. When discrepancies arise between engineering specifications and architectural specifications, the engineer's specifications shall govern. 13. These plans, specifications, details, and designs are the sole property of Steven F. Kubitschek. Construction is limited to a one time use on the property named herein. These pages may not be displayed, copied, or used in any way without the express written permission of Steven F. Kubitschek. 14. All work completed by Eric Alan Hare & his associates has been reviewed by Steven F. Kubitschek. Steven F. Kubitschek assumes all control & ownership for all content within this set of documents other than those documents prepared by others. Oak Park Blvd Geary Rd A0.1
2 C1
3 C2
4
5 C4
6 3/23/2016 2:07:26 PM A2.1
7 3/23/2016 2:07:10 PM SITE IMP. PLAN A2.2
8 3/23/2016 2:06:56 PM STORY A2.3
9 3/23/2016 2:07:57 PM ELECTRIC LEGEND QUANTITY DESCRIPTION 9 6" RECESSED CEILING LIGHT 9 WALL MOUNTED LIGHT, SEE SHEET A6.1 FOR TYPE FLOOR PLAN A4.1
10 3/23/2016 2:07:47 PM ROOF PLAN A5.1
11 3/23/2016 2:08:12 PM EXTERIOR ELEVATIONS A6.1
12 3/23/2016 2:08:46 PM EXTERIOR ELEVATIONS A6.2
13 3/23/2016 2:09:50 PM BUILDING SECTIONS A6.3
14 3/23/2016 2:10:30 PM SITE SECTIONS A6.4
AREA CALCULATIONS- COMPARISON TO PREVIOUS SUBMITTAL DR15-13 PREVIOUS- DR15-13 & DR17-14
PROJECT DATA PROJECT ADDRESS: 3357 Kincheloe Ct. Lafayette, CA. APN: 230-130-013 OCCUPANCY: R3/U CONSTRUCTION TYPE: TYPE V-B STORIES: 2 Stories SETBACK REQUIREMENTS: Front Sides Rear 25' 20' 15' FLOOR
More informationA1.1 COVER SHEET PROJECT DATA. PROJECT DIRECTORY LEGAL OWNER William & Catherine Bucher 1203 Upper Happy Valley Rd. Lafayette, CA
PROJECT DATA ABBREVIATIONS & AND > ANGLE @ AT CL CENTERLINE o DIAMETER # POUND OR NUMBER (E) EXISTING AB ANCHOR BOLT ABV ABOVE ACOUS ACOUSTICAL ADJS ADJUSTABLE AFF ABOVE FINISH FLOOR AGGR AGGREGATE ALUM
More informationNOTICE OF PUBLIC HEARING
Zoning Administrator NOTICE OF PUBLIC HEARING Planning & Building Department Director, or its designee BODY: Zoning Administrator DATE: Thursday, May 28, 2015 TIME: 2:00 p.m. (please see the agenda for
More informationA.S.F. ADJ. A.F.F. ALUM. ATTN. BATHRM. BLDG. BLKG. BD. CAB. CLG. CMU COL. CONC. CONT. C.T. DIA. DBL. DWGS. EA. E.J. ELEV. EQ. EXIST. EXT. F.B.O.
A.S.F. ADJ. A.F.F. ALUM. ATTN. BATHRM. BLDG. BLKG. BD. CAB. CL CLG. CMU COL. CONC. CONT. CP C.T. DIA. DBL. DN DWGS. EA. E.J. ELEV. EQ. EXIST. EXT. F.B.O. F.O.F. F.O.S. FIN. FLR. GA. GALV. GL. GLU-LAM.
More informationSecond Story Addition. 703 Cornell Avenue. Albany, CA. Project Description
Perspective View Second Story Addition architect Avenue Albany, CA Project Data Project Description Zoning Information Work to consist of addition of 66 s.f. second floor over existing garage, construction
More informationA-1.1. J. A l l e n S a y l e s GENERAL NOTES DRAINAGE DETAIL ABBREVIATIONS MICHAEL & DIANE ARCHER DRAINAGE PLAN SURVEY PREPARED BY DON VEGVARY
\\SERVER\DriveF\2015 CAD\1501 Archer\Plot\01PLOT.dwg, 3/22/2016 4:45:56 PM, DWG To PDF.pc3 GENERAL NOTES DRAINAGE DETAIL 1 SCALE: N.T.S. 1 - ENERGY DISSIPATER J. A l l e n S a y l e s A R C H I T E C T
More informationCOLUMBIA HALL ELEVATOR MODERNIZATION
COLUMBIA HALL MODERNIZATION Architects STATE PROJECT NO.: H27-6008 UNIVERSITY OF SOUTH CAROLINA A.C.T. ALUM. BD BLKG C.J. C.T. CMU CONC. CONT CPT CR DTL. E.J. ELEC. EQ EXIST./EXG EXP FE FEC FF FLR FTG
More informationALVARADO STREET SAN FRANCISCO, CA VARIANCE APPLICATION
621-23 ALVARADO STREET SAN FRANCISCO, CA 94114 VARIANCE APPLICATION PROJECT LOC. ABBREVIATIONS LEGEND EXISTING FRONT ELEVATION VICINITY MAP (NO SCALE) OWNER: 621 ALVARADO ST, LLC PHONE: 707-373-0832 400
More informationPROJECT DIRECTORY PROJECT SUMMARY
A/C AIR CONDITIONING A.C. ASPHALTIC CONCRETE PAVING A.D. AREA DRAIN A.F.F. ABOVE FINISH FLOOR ALUM. ALUMINUM BD. BOARD BLDG. BUILDING BLKG. BLOCKING BOT. BOTTOM C.L. CENTER CLG. CEILING CLR. CLEAR C.M.U.
More informationDemolition Plans Salisbury Management NEW STORY SCHOOL
Demolition Plans BUILDING CODE REVIEW REFERENCE CODE: NEW CONSTRUCTION 29 INTERNATIONAL EXISTING BUILDING CODE REVATIONS TO EXISTING BUILDING ADDITION(S) DRAWING # TITLE ALTERATION(S) D-............ COVER
More informationFRANKLIN/CLAYTON ASSOCIATION WAREHOUSE
G E N E R A L N O T E S: ABBREVIATIONS THESE DRAWINGS ARE INSTRUMENTS OF THE ARCHITECTURAL SERVICES RENDERED BY PLLC. AS SUCH THEY ARE PROPERTY OF. THEY ARE NOT TO BE USED, COPIED OR REPRODUCED WITHOUT
More informationDisclaimer for Review of Plans
Disclaimer for Review of Plans The San Francisco Planning Code requires that the plans of certain proposed projects be provided to members of the public prior to the Cityʹs approval action on the project.
More informationCOMPETITION GYM FLOORING AND BLEACHERS
COMPETITION GYM FLOORING AND BLEACHERS AT PAT NEFF MIDDLE SCHOOL NORTHSIDE INDEPENDENT SCHOOL DISTRICT 5227 EVERS RD. SAN ANTONIO, TEXAS 78238 B O A R D O F T R U S T E E S KATIE N. REED M'LISSA M. CHUMBLEY
More information100% CONSTRUCTION DOCUMENTS BID SET Architect's Project Number: U MATERIAL DESIGNATIONS COMPACTED EARTH WOOD (ROUGH) WOOD (FINISHED)
C I 2X3 GR A TE 84.23 3 08 UNIVERSITY OF SOUTH CAROLINA GREEK VILLAGE SIGNAGE & IMPROVEMENTS 850 BLOSSOM STREET COLUMBIA, SC 29208 USC Project Number: CP0033886 00% CONSTRUCTION DOCUMENTS BID SET Architect's
More informationI S GENERAL NOTES TITLE SCALE: 1/4" = 1'-0" ARCHITECTURAL SCOPE
GENERAL NOTES 1. LAWS AND ORDINANCES: AS USED HEREIN SHALL MEAN ALL COUNTY, STATE AND NATIONAL CODES, ORDINANCES, STANDARDS, RULES AND REGULATIONS OF ANY NATURE WHICH ARE PERTINENT TO, OR REGULATORY OVER,
More information#G445 Plans, 48'x28' x 10' detached garage with bonus room By SDS-CAD Specialized Design Systems
Architectural asphalt shingles and horizontal True Wood 7" Reveal siding over structural panel. Nailing schedule is 6" on ends 12" on centers 6d nails. Trusses are engineered on Bonus attic trusses 24"
More informationGENERAL NOTES 1. ALL WORKS SHALL COMY WITH THE REQUIREMENTS OF THE FOLLOWING CALIFORNIA CODES, REGARDLESS OF DETAILS OR ANS: 2016 CALIFORNIA BUILDING CODE (CBC) 2016 CALIFORNIA ELECTRICAL CODE (NEC) 2016
More informationA. FLORIDA FIRE PREVENTION CODE (2010) B. FLORIDA BUILDING CODE. MECHANICAL (2010) C. FLORIDA BUILDING CODE. PLUMBING (2010)
TYPICAL DRAWING NOTES TYPICAL DRAWING NOTES APPLICABLE BUILDING CODES GENERAL PROJECT SCOPE & REQUIREMENTS CONTRACT REQUIREMENTS AFFECTING ALL TRADES. IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND EACH
More informationARCHITECTURE DESIGN INTERIORS
PROJECT CONSULTANTS PROJECT INFORMATION ARCHITECT APPLICABLE BUILDING CODES: 23 NORTH GORE AVENUE SUITE 303 WEBSTER GROVES, MO 63119 PHONE: CHRIS PIKE: EMAIL: CPIKE@TAG-STL.COM JOSEPH "AJ" CALTETT: EMAIL:
More informationProject Name: the candlelight. Project No. Scale: sewer line. water line 1 8"=1'-0"
sewer line water line Site Plan scale: 1/8" = 1' 1709 POWERS BLVD. RYAN GLENN SUBDIVISON PHASE 1, BLOCK 5, LOT 3 10,84 SQ. FT. slope grade away from foundation min " in 10' or 5% if 10' is unavailable
More informationDisclaimer for Review of Plans
Disclaimer for Review of Plans The San Francisco Planning Code requires that the plans of certain proposed projects be provided to members of the public prior to the Cityʹs approval action on the project.
More informationREPAIR BUILDING ENVELOPE
NO. DESCRIPTION 0 REPAIR BUILDING ENVELOPE AT CCAC NORTH CAMPUS TEAM RADELET McCARTHY POLLETTA INCORPORATED ARCHITECTS AND INTERIOR DESIGNERS 00 FIRST & MARKET BUILDING 00 FIRST AVENUE PITTSBURGH, PENNSYLVANIA
More informationARCHITECTURAL SHEET INDEX MECHANICAL SHEET INDEX ELECTRICAL SHEET INDEX
WILLIAMS MALL W:\48\18-4802\Drawings\WSU BIO-SCIENCE BLDG. STEAM BOILER\Sheets\18-4802-G1.dwg, 6/22/2018 2:04:17 PM SHEET A1 M1 M2 M3 M4 M5 M6 E1 E2 ARCHITECTURAL SHEET INDEX DESCRIPTION ARCHITECTURAL
More informationProposal Request (attachment to AIA Form G709)
Proposal Request (attachment to AIA Form G09) PR No: PR-0 Date: January, 06 Project: Great Work Montessori School Owner: Great Work Inc. Architect: Cuningham Group Copy To: File DESCRIPTION OF WORK The
More informationHINSDALE, ILLINOIS FOR MATERIAL INDICATIONS GRAVEL CMU
ABBREVIATIONS AND SYMBOLS MATERIAL INDICATIONS DRAWINGS INDEX CERTIFICATION AB AC AC.T. ADA ANCHOR BOLT ACOUSTIC ACOUSTICAL TILE AMERICANS WITH DISABILITIES ACT DL. DR. DRWG. DS DEAD LOAD DOWN DOOR DRAWING
More informationCLASSROOM MODIFICATIONS AT MURRAY LASAINE ELEMENTARY
MODIFICATIONS AT PROGRAM MANAGER ARCHITECT CIVIL ENGINEER MEP ENGINEER 399 BRIDGEVIEW DRIVE NORTH CHARLESTON, SC 29405 8435294989 CONT: RONALD KRAMPS CUMMING CONSTRUCTION CORPORATION 3896 LEEDS AVENUE
More informationPROJECT DATA USE GROUP M M TYPE OF CONSTRUCTION IIB NUMBER OF STORIES 1 HIGH RISE BUILDING COVER MALL IS BUILDING FULLY SPRINKLERED
GENERAL TES ABBREVIATION PROJECT DATA CONTACTS 1. CONTRACTOR TO VERIFY ALL FIELD CONDITIONS TED PRIOR TO COMMENCEMENT OF CONSTRUCTION. FIELD CONDITIONS T AGREEING WITH CONSTRUCTION DOCUMENTS SHALL BE BROUGHT
More information* RESIDENTIAL PLAN REVIEW *
CITY OF DES MOINES, IOWA COMMUNITY DEVELOPMENT DEPARTMENT PERMIT AND DEVELOPMENT CENTER 602 Robert D. Ray Drive DES MOINES, IOWA 50309 Phone: 515.283.4200 Facsimile: 515.283.4270 Based on the scope of
More informationCustom 22' x 40' - 16' Tall Garage Plan #g227 By SDS-CAD Specialized Design Systems
P O Box 34 Mendon, Utah Custom 22' x 40' - 16' Tall Garage Plan #g22 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical
More information1. Complete Building Permit Application forms on page 2. Include septic system design approval from the Washington County Health Department.
City of Goshen Instructions for Residential Permit Application Why do you need a building permit? Your home is a large investment, and if your construction project does not comply with the codes adopted
More information2,772 SQ. FT. ALLOWED FAR 1,386 SQ. FT. (50%) EXISTING MAIN FLOOR AREA PROPOSED FLOOR AREA TOTAL SQ. FT SQ. FT SQ. FT.
GENERAL NOTES 1. All work shall conform to the California Residential Code, 2016 Edition; California Plumbing Code, 2016 Edition; California Mechanical Code, 2016 Edition; California Electrical Code, 2016
More informationCustom 30 x 48-14' Tall Garage Plan #g226 By SDS-CAD Specialized Design Systems
P O Box 34 Mendon, Utah Custom 30 x 48-14' Tall Garage Plan #g226 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical Section
More informationT T LEGAL DESCRIPTION: LEGEND X FOUND MONUMENT AS NOTED A.M. ~ AS MEASURED IN FIELD REC. ~ DEED OR PLAT DISTANCE PL ~ PROPERTY LINE FF ~ FINISHE
T T LEGAL DESCRIPTION: LEGEND X 99.44 FOUND MONUMENT AS NOTED A.M. ~ AS MEASURED IN FIELD REC. ~ DEED OR PLAT DISTANCE PL ~ PROPERTY LINE FF ~ FINISHED FLOOR CALLED NORTH N EXIST. SPOT ELEVATION N00 04'58"W
More informationCity of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)
City of Hughson Building Safety Division 7018 Pine Street Hughson, CA 95326 (209) 883-4054 RESIDENTIAL ATTACHED PATIO COVERS Patio covers are one story roofed structures not more than 12 feet above grade,
More informationEXW3 EXISTING DOWEL NEW FOOTING TO EXISTING WALL WITH 3-15M DOWELS, DOWEL THE NEW
-4 /4" 8" 4'-9 /" 6'-4" '-8" DEPRESS TO ACCOMODATE DOOR ABOVE DOWEL NEW FOOTING TO WITH 3-5M DOWELS, DOWEL THE NEW S TO THE S WITH 5M @ 4" O.C. VERTICALLY, PROVIDE -5M BARS 6" LONG IN THE FOOTING 4'-9"
More informationfront elevation right elevation
Ridge Approx. 21'-7" :12 continuous ridge vents 30 year asphalt shingles 8" Lap Hardie Plank Siding 3 1 2" MiraTech window & door trim 3 1 2" MiraTech corner trim 40" Tall Foundation Wall front elevation
More informationMinimum Residential Plan Submittal Requirements
Minimum Residential Plan Submittal Requirements BI-24 CRC 2016 In order to make your permit application and the plan review process go as smooth as possible it is important to have a general understanding
More information2'-0 1/2" 1'-8" 9'-7" TOILET BATHROOM 9 VINYL T.P. 3'-8" H.B. 48'-0" W.H. 6'-10" 13'-2" 12'-0" 6'-10" 7'-2" 6'-0" 12'-0" 6'-10" 25'-2"
'-0" '-" '- /" '- /" '-" '-0" '-0 /" '-0" '-0" '-0" '-0" '-0" '-0" '-0" '-0" '-0" 0 Lincoln Street P O Box 0 0-0 Phone: -- Fax: -- '-0" '-0" '-0" '-0" 0'-0" '-0" '-0" '-" '-" '-0" '-0" '-" '-" '-0" '-0"
More informationCITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements
CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT 1 East Franklin Street Phone: 301-790-4163 Third Floor Hagerstown, MD 21740 Fax: 301-791-2650 BUILDING PERMIT APPLICATION FOR RESIDENTIAL ACCESSORY
More information6" TRIM AT GARAGE DOORS (TYP) 6" TRIM (TYP) OPTIONAL PATIO DOOR
GABLE END x0 TRIM (TYP) A6. PTD. ALUM GUTTER (TYP) MODEL 67 - OVATION MODEL - BRAVO 0.670.7 09'- /8" 00'-0" " WATER 6" CORNER TRIM (TYP) 6" TRIM AT GARAGE DOORS (TYP) OPTIONAL PATIO DOOR AMERICAN TRADITIONAL
More information6'-0" G-4 ADJUSTABLE SHELVING 2'-0" 4'-5" MOP SINK STORAGE '-0" 2'-0" 26'-6" G-4 6' X 4' OPENING WITH SHUTTER BASE CABINETS 34" FOR ADA 20'-0"
2 G1 3'4" 4'0" ROOM FINISH SCHEDULE 4'0" F.F. WINDOW DETAILS GROUT CORES SOLID GROUT CORES SOLID 3 G1 #5 BARS HOLLOW METAL FRAME INSULATED GLASS 1" CLEAR INSULATED (U=0.45) CAULKING & BACKER ROD PREFORMED
More informationGARAGE MAIN FLOOR PLAN
12'-0" 4'-6" 3'-0" 4'-6" 3040 14'-0" LADDER LT LINE BUNK CABIN 11'-4" x 13'-4" 14'-0" BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS.
More informationGARAGE MAIN FLOOR PLAN
#G389 14' X 24' X 8', Custom detached garage By Page 1 Page 2 Page 3 Page 4 Page BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. GARAGE
More information104'-0" 26'-0" 26'-0" 26'-0" 26'-0" 3'-0"x3'-0" 5'-0" 5'-0" 9'-0" 9'-0" 5-0 x 4-0 EGRESS. 5-0 x 4-0 EGRESS 2 A-5 4'-0" 4'-0" 3'-10" 3'-10"
'-0" '-6" 0'-" 6'-" 0 '-0"x'-0" NC. '-0"x'-0" - UNIT# ENTRY BEDROOM # '-6" '-0" CANT. LAYER /" 5 F. 0 MIN. RATED 6" FLOOR TRUSSES @ 6" o.c. 6" FLOOR TRUSSES @ 6" o.c. LAYER /" 5 F. NC. 0 MIN. RATED '-0"
More information30 YR. ASPHALT ROOF SHINGLES HARDIE PLANK LAP SIDING SEE FIRST FLOOR PLAN FOR PORCH ROOF FRAMING DETAILS 3'-0" 2-2 X 8 HEADER COVERED PORCH 9'-4"
FAMILY ROOM CLG. LINE BSMT CLG. 20" '-0" 2 x 2 TR. WD. PICKETS @ 4" O/C FL. TRUSS 4" X 4" TREATED COL. 4" HIGH " X " BRICK COL. 2-2 X TR. BAND WOOD 44" HIGH 3'-0" T J I ROOF RAFTER SOLDIER COURSE 24" o
More informationTNH-SC-43-B DRAWING INDEX SYMBOLS AND ABBREVIATIONS AUG. 22, 2014 TNH-SC-43-B TRADITIONAL HOME SERIES C S 1.0 A 1.0 A 1.1 A 2.0 A 2.1 A 3.0 E 1.
TRADITIONAL DRAWING INDEX SYMBOLS AND ABBREVIATIONS 5 DISCLAIMER OF WARRANTIES To the maximum extent permitted by law, Moser Design Group, Inc disclaims all warranties, express or implied, including the
More informationMAIN FLOOR PLAN. #G x 14 x 8 Shed - Chicken Coop By SDS-CAD Specialized Design Systems 10'-0" 3'-0" 1'-0" 14'-0" 14'-0" 1'-0" 6'-0" 3'-0"
10'-0" BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. BARN TO BE BUILT AS PER LOCAL CODE REQUIREMENTS 14'-0" BWP BWP BWP ABWP 101
More informationSITE / BUILDING PLAN 10/18/16 10/18/16 A+M ARCHITECTS, LLC REINF. ANGLE REQUIRED AT ALL ROOFTOP UNITS WHERE "X" EXCEEDS 8"
10'-7" 4 7/8" 30'- 20'-7 3/8" WH WH A+M ARCHITECTS, LLC TO THE BEST OF MY KNOWLEDGE AND BELIEF, ALL OCCUPANTS WITHIN THE BUILDING ARE IN COMPLIANCE WITH APPLICABLE ILLINOIS STATE PLUMBING CODES PERTAINING
More informationResidential Project Example
A r c h i t e c t u r e D e p a r t m e n t 5 0 0 N o r t h V e r d u g o R o a d G l e n d a l e, C a l i f o r n i a 9 2 0 8-2 8 9 4 ( 8 8 ) 2 4 0-0 0 0 e x t. 5 5 2 8 w w w. g l e n d a l e. e d u /
More informationCity of San Pablo Community Development Department Building Inspection Division Plan Review & Permit Requirements
Table of Contents City of San Pablo Community Development Department Building Inspection Division Plan Review & Permit Requirements General Requirements Application & Processing Procedures o Plan Requirements
More informationEXIT CONTROL 108 SIM LAB 105 SIM LAB 106 BUSINESS 2465 SF 100 GROSS 25 OCCUPANTS CLASSROOM 104 DATA / COMM 103 SCOPE OF WORK
DN USCL NURSING OSE# H7-955 76 HUBBARD DRIVE LANCASTER, S.C. 970 DN DN DN UP UP 05 CONTROL 08 06 07 MECH 0 GOODWYN MILLS CAWOOD 0 East Washington Street, Suite 00 Greenville, SC 960 Tel 86.57.060 GMCNETWORK.COM
More informationOne and Two Family Additions
One and Two Family Additions An addition to a house, duplex, garage, or an accessory structure requires a building permit prior to performing any construction. Building Department & Permit Office Mon-Fri
More informationReview and take action on site plan for a new 15,300 square-foot building on Parcel VH-1517, North Kimps Court
Meeting Date: March 2, 20 Item: #20 VILLAGE OF HOWARD STAFF REPORT REPORT TO: REPORT FROM: REPORT SUBJECT: Burt McIntyre, President Village Plan Commission Village Board of Trustees Dave Wiese, Director
More informationCOMMERCIAL OR RESIDENTIAL NEW BUILDINGS, REMODELS AND ADDITIONS
COMMERCIAL OR RESIDENTIAL NEW BUILDINGS, REMODELS AND ADDITIONS BUILDING & SAFETY DIVISION (530) 795-4910 ext. 112 or 117 FAX (530) 795-4935 318 First Street Winters, CA 95694 This is a list of the minimum
More informationDRAWING INDEX: 25.00' PL N14º 11'W
DRAWING INDEX: 5.00' PL N4º 'W SITE ROOF PLAN SURVEY PROPOSED FLOOR DEMOLITION PLANS PROPOSED ELEVATIONS BUILDING SECTIONS SUPPLEMENTAL SQUARE FOOTAGE EXHIBIT PLANS ELEVATIONS 0' REAR SETBACK REDWOOD TREE
More informationGARAGE MAIN FLOOR PLAN
BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. SHED TO BE BUILT AS PER IRC, UBC OR CURRENT LOCAL CODE To the best of my knowledge
More informationCustom 24 x 26 Garage Plan Roy Hartmann Plan #g218 By SDS-CAD Specialized Design Systems CLIENT
P O Box 34 Mendon, Utah Custom 24 x 26 Garage Plan Plan #g218 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical Section
More informationDATE: 4/1/2014 SCALE: 3/16"=1'- 0" SHEET:
Terrace Level First Floor Second Floor Total Back Porch Front Porch Finished NA 1397 SF 743 SF 2140 SF 63 SF 195 SF Unfinished NOTES: All dimensions are framing dimensions, NOT finished dimensions Exterior
More informationCRM Homes BUILDER Mangan Drafting Jim Mangan
BACK ELEVATION 1/8" = 1' LEFT SIDE 1/8" = 1' RIGHT SIDE 1/8" = 1' ROOF LINE NTS FRONT VIEW 1/4" = 1' A-1 Springfield MO 65610 Fremont Hills Lot 57 12/12 12/12 14/12 14/12 12/12 12/12 12/12 MAIN ROOF PITCH
More informationTenant Fit-Out for PLCB / Waynesboro Mall
Tenant Fit-Out for PLCB / CODE REVIEW: PROJECT DESCRIPTION TENANT BUILD OUT PROPOSED USE SALE OF BEVERAGE ALCOHOL / PLCB SPRINKLERED: YES ALLOWABLE BUILDING HEIGHT & AREA: GROUP M / TYPE VB ALLOWED 1 STORY
More informationFORNEY, TX PACIFIC JOSHUA HOUGH OFFICE BUILDING. 3D View 2 Copy 1 GENERAL NOTES ABBREVIATIONS LIVE DEAD ROOF...
L:\ARCHITECTURE\Jobs\207 Forney\Dropins\joshua hough-office conv\-sd\ Pacific_Joshua Hough2.rvt COVER SHEET Checked by Checker Scale A-0.0 PACIFIC FORNEY, TX 26 /26/207 3:52:3 PM GENERAL NOTES ABBREVIATIONS
More informationCITY OF CALABASAS RESIDENTIAL PLAN REQUIREMENTS 1 OF 5 8/2017 PLAN INFORMATION
1 PLAN INFORMATION Residential plans must be legible and capable of digital scanning. All sheets shall be the same size and distinctly labeled with a sheet title and number. The minimum dimension of the
More informationGARAGE MAIN FLOOR PLAN
BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. SHED TO BE BUILT AS PER IRC, UBC OR CURRENT LOCAL CODE To the best of my knowledge
More informationINFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS
INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS November 2018 Contents 1. Introduction... 1 2. Ontario Building Code and Second Dwelling Units... 1 3. How Do I Make My Secondary Dwelling Unit
More informationRESIDENTIAL DETACHED ACCESSORY STRUCTURES
RESIDENTIAL DETACHED ACCESSORY STRUCTURES *A Building permit is required for any alteration or addition to any existing building or structure. MN State Building Code Section 1300.0120 Subpart 1 Permit
More information30 X 40 POLE BARN 12 HIGH SIDE WALLS 2-12 WIDE X 10 HIGH SECTIONAL GARAGE DOORS OPTIONAL WINDOWS DETAILS INCLUDED
30 X 40 POLE BARN 12 HIGH SIDE WALLS 2-12 WIDE X 10 HIGH SECTIONAL GARAGE DOORS OPTIONAL WINDOWS DETAILS INCLUDED 3 ENTRY DOOR METAL ROOF METAL SIDING GABLE ROOF, 4/12 PITCH INDEX PAGE DESCRIPTION 1 FRONT
More informationTO THE DRAWINGS AND THE PROJECT MANUAL
NO. TO THE DRAWINGS AND THE PROJECT MANUAL PROJECT NAME: Elementary School and High School Additions and Renovations CLIENT NAME: Peaster ISD LOCATION: Peaster, Texas PROJECT NUMBER: 803-0-0, 803-0-0 PROPOSAL
More informationProud of its Heritage, Preparing for its Future
TUSTIN Proud of its Heritage, Preparing for its Future Revised August 2013 USER GUIDE FOR THE INSTALLATION OF RESIDENTIAL ROOM ADDITIONS OR ALTERATIONS PURPOSE This guide describes the City of Tustin s
More informationREAR PORCH/COVER PATIO
REAR PORCH/COVER PATIO 1108 S. BUCHANAN STREET ARLINGTON, VA PROJECT TEAM DRAWING INDEX 9818 SUDLEY MANOR DR MANASSAS, VA DESIGNER H.D. DESIGN BUILD, LLC HENDERSON E. DIAZ IVE MANASSAS, VA GENERAL DRAWINGS
More informationREGULATIONS FOR RESIDENTIAL OPEN WOOD DECKS
REGULATIONS FOR RESIDENTIAL OPEN WOOD DECKS TOTAL PERMIT FEE DUE WILL BE $375.00 ($290.00 IS REFUNDABLE AFTER POST HOLE AN FINAL INSPECTION) Furnish (2) copies of a site/plot plan drawn to scale for wood
More informationTP: 89'-0" BP: 86'-6 1/4" 2'-0" Typ TP: 89'-0" BP: 86'-6 1/4" 2'-0" Typ S201 TW: 89'-0" TF: 86'-0" S201 TW: 87'-11 1/4" S201 TF: 86'-10 1/4" S201
Resource reginc.com 0.. '-" P: '-" 0'-0" " P: '- /" 0'-" '-" '-0" '-0" 0'-0" '-0" '-" '- /" TF: '-0" TW: '-0" TF: '-0" TW: '-0" TF: '-0" TW: '- /" TF: '-" " Typ Sim. P: '-" " TF: '-0" C '- /" '-" Varies
More informationADA RESTROOM 79 LF EXISTING ANDERSON MAINTENANCE BUILDING (E) SNOW STORAGE AREA: 160 SF EXISTING STORAGE BUILDING (E) ELECTRICAL PAD
T ectoniccop yright07 T ectoniccop yright07 0BOBADAMSDRIVESTEAMBOATSPRINGS,COLORADO8047GENERAL NOTES SHEET INDEX. ALL RIGHTS RESERVED. THE ARRANGEMENTS, DECISIONS, DETAILS AND CONCEPTS DEPICTED HEREIN
More informationTwo complete sets of plans that are legible and drawn to conventional scale are required to be submitted with the Building Permit Application Form.
The Homeowner s Building Application Checklist for Constructing a Residential Accessory Building This checklist provides homeowners a summary of the Building Permit submission requirements for constructing
More informationRESIDENTIAL BUILDING PERMIT APPLICATION ( MINIMUM Building Requirements-Page 6)
www.shawneeok.org RESIDENTIAL BUILDING PERMIT APPLICATION ( MINIMUM Building Requirements-Page 6) Planning Office 405-878-1666 222 N Broadway Ave Shawnee OK 74801-6917 FAX: (405) 878-1587 cosinspections@shawneeok.org
More information14' x 24' Garage Plan
14' x 24' Garage Plan SDS-CAD Specialized Design Systems www.sdscad.com email sdscad@pcu.net Copyright 2002 14'-0" (vert)-g 24'-0" 12 in 12 GARAGE 13'-4" x 23'-4" 12 in 12 3068 19'-0" 3'-0" 2'-0" 24'-0"
More informationBUILDING PERMIT SUBMISSION CHECKLIST NEW SINGLE-FAMILY RESIDENCE NEW TWO-FAMILY RESIDENCE NEW MULTIPLE SINGLE FAMILY (TOWNHOUSE)
BUILDING PERMIT SUBMISSION CHECKLIST NEW SINGLE-FAMILY RESIDENCE NEW TWO-FAMILY RESIDENCE NEW MULTIPLE SINGLE FAMILY (TOWNHOUSE) PROJECT SITE ADDRESS CHECKLIST PREPARED BY: ZONING DISTRICT PREPARER S PHONE
More informationMORGAN II DESIGN CRITERIA: 2012 International Residential Code with Georgia Amendments
DESIGN CRITERIA: 202 International Residential Code with Georgia Amendments Roof: Live Load = 20 psf Dead Load = 0 psf Floors: Live Load = 40 psf Dead Load = 0 psf TYPE CONSTRUCTION Type V-B Residential
More informationA PORTION OF THE LINK IS TO REMAIN AND BE CONVERTED TO A NEW ENTRY VESTIBULE. SEE ADDITIONAL DRAWING FOR THIS WORK.
UNK WELCH HALL DEMOLITION 2504 19TH AVENUE KEARNEY, NE 68849 PROJECT NUMBER: K025P005 BUILDING NOTES: THE ORIGINAL BUILDING WAS AN EARLY DORM WITH 2 STORIES AND A PARTIAL BASEMENT. A ONE STORY ADDITION
More informationARCHITECTURAL REVIEW BOARD SET SEPTEMBER 14, 2017
ARCHITECTURAL REVIEW BOARD SET SEPTEMBER 4, 07 SEPTEMBER 4, 07 RENDERING Date: /07/6 9/4/07 :44: AM T-0.00 ABBREVIATIONS A/C AIR CONDITIONING N NORTH A.C. A.D. A.F.F. ALUM. BD. ASPHALTIC CONCRETE PAVING
More information1. INVITATION TO BID: CHANGE the date for receiving bids from 10 March 2015 to THURSDAY, 12 MARCH The time shall remain the same.
03/04/15 PHASE 2 MULTIPURPOSE RENOVATION DREAMS OF WILMINGTON, INC. To: ALL BIDDERS & PLAN ROOM From: ARCHITECT No. of pages: 5 pdf CHANGES TO PROJECT MANUAL 1. INVITATION TO BID: CHANGE the date for receiving
More informationCustomer A101. Front Elevation. Roof Peak 24' /32" Roof 17' - 6" Main Floor 9' - 6" Floor Joist 8' - 6" Basement 0' - 6" Grade 0' - 0"
/300 ROOF VENTILATION REQUIRED TYPICAL ROOF OVERHANG '-6" 2 7 Peak 24' - 9/32" 7' - 6" 9' - 6" Floor Joist Grade 0' - 0" Front Elevation 24"x8" STRIP. FOOTING (TYP.) MIN. 42" HIGH GUARD AROUND DECK (TYP.)
More informationTOWNHOUSES at WASHINGTON AVENUE
TOWNHOUSES at C H R I S T I N A G R I F F I N A R C H I T E C T 1 0 S p r i n g S t r e e t, H a s t i n g s - o n - H u d s o n, N Y 1 0 7 0 6 ARCITECTURAL REVIEW BOARD SUBMISSION 0-17 OWNER ARCHITECT
More informationA3.01 OUTDOOR WALKWAY STORAGE 1525 WOMEN CLASSROOM 1526 MEN 1520E STORAGE EXAM CLASSROOM 1521A CLASSROOM STORAGE OUTDOOR WALKWAY A3.
1 A3.01 GENERAL SHEET NOTES 1523 1522B 1522-A 1522A 1524 CONFERENCE DUCT SHAFT 1508 ELECT./ JAN. 1521B 1521A 1520 1520 LEVEL 2 KEY PLAN 2 1/8" = 1'-0" 1526 MEN 1520E STORAGE 3 1 2 STORAGE 1 A3.01 1 2 1525
More informationApplications for building permits will not be reviewed until all of the required information has been submitted.
NOTICE: Applications for building permits will not be reviewed until all of the required information has been submitted. Once all items are submitted a minimum of ten (10) working days are required to
More informationSantee Court Market & Food Hall Concept Los Angeles, CA. Essex Property Trust July
Santee Court Market & Food Hall Concept Los Angeles, CA Essex Property Trust July 11 2017 Buildings 700 & 718 Site Plan LOS ANG E LE S STR E ET BLDG 718 BLDG 700 7TH STR E ET COURTYARD SEAT COUNT BLDG
More informationTown of Kingsville. Building Department
Town of Kingsville Building Department GUIDE TO ACCESSORY STRUCTURES AND DECKS FOR BUILDING PERMITS www.kingsville.ca 2017 Disclaimer: The fees and by-law information compiled within this guide are for
More informationGARAGE MAIN FLOOR PLAN
30 year dimensional shingles and Metal Verticle siding over structural sheathing. Nailing schedule is " on ends 12" on centers d nails. Trusses are engineered on 24" and framing is 2" x " on 1" centers.
More informationNOTICE OF PUBLIC HEARING
Zoning Administrator NOTICE OF PUBLIC HEARING Planning & Building Department Director, or its designee BODY: Zoning Administrator DATE: March 24, 2016 TIME: 2:30 p.m. (please see the agenda for estimated
More informationSANDTOWN CROSSING PROFESSIONAL OFFICE PARK Atlanta, GA
Atlanta, GA LOCATED AT CAMP CREEK PARKWAY AND CAMPBELLTON ROAD For Sale or Lease Single units start at 1,176sf and can be combined to exact specification Custom Designed Medical and Professional finishes
More informationABBREVIATIONS PROJECT NOTES PROJECT DIRECTORY DRAWING INDEX. Rick McGee and Shannon Miller 823 Alvarado Road Berkeley, CA VICINITY MAP
ABBREVIATIONS PROJECT NOTES PROJECT DIRECTORY DRAWING INDEX A.C. Acous. Adj. A.F.F. Aggr. Alt. Al. Approx. Arch. Avg. Bitum. Bldg. Blk. Blkg. Bm. B.O. Bot. B.U. Cab. Ceil. Cem. Cer. C.L. Clg. Clr. Col.
More informationCopyrighted Home Plan 2011 Natural Element Homes, LLC
29'-0" SQUARE FOOTAGE 6'-0" PORCH 3'-0" 6'-0" 2'-0" 3'-6" 8'-0" 2'-4" 3'-8" 6'-7" 3'-11" BCD3756-2 BCA2420T 3-0 9LITE BATH WOOD STOVE 10'-0" 2-4 15'-10 1/2" 3'-11" 6'-0" 11'-9 1/2" 15 R. @ 7 5/8" 14 T.
More informationBUILDING PERMIT APPLICATION
TOWN OF LEICESTER 132 Main Street Post Office Box 197 Leicester, New York 14481 Phone: (585) 382-3231 FAX: (585) 382-9766 BUILDING PERMIT APPLICATION All Town of Leicester property owners are required
More informationPulaski County, Virginia Typical Carport Enclosure Details Based on the 2012 International Residential Code
Pulaski County, Virginia Typical Carport Enclosure Details Based on the 2012 International Residential Code Carports enclosed into one-story garages or living spaces must be constructed in conformance
More informationONE AND TWO FAMILY DWELLING PERMIT APPLICATION REQUIREMENTS
ONE AND TWO FAMILY DWELLING PERMIT APPLICATION REQUIREMENTS Submit a permit application with all applicable items completed, including inserts, when you construct a new building, construct an addition,
More informationPulaski County, Virginia
Pulaski County, Virginia Typical Carport Enclosure Details Based on the 2009 International Residential Code CONTENTS General Requirements... 2 Emergency Escape and Rescue... 2 Foundation and Floor... 3
More informationGarage Construction. Permit Guide. Development Center. General Information. Zoning Ordinance Requirements. Building Code Requirements
General Information Site Card. Before starting construction, post the site card (issued by the City) in a front window visible from the street. Miss Dig. Before you dig, call Miss Dig at 800.482.7171 This
More informationLeft Elevation. Front Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,842. Scale : 1/4" = 1'
Plan Name 4 4" Window and door trim. (Street facing facades) 4" Corner Boards 4" Vertical Cedar Siding Left Elevation Lap siding over approved building wrap over 1 2" OSB sheathing. Front Elevation Stone
More informationPROJECT INFORMATION PROJECT NUMBER 1706 SINGLE DETACHED DWELLING - RENO 4208 VARMOOR ROAD NW CALGARY ALBERTA
BERZE RESIDENCE 4208 VARMOOR ROAD, NW CALGARY ALBERTA CLIENT PROJECT INFORMATION NAME BELA & BOGLARKA BERZE PROJECT NAME BERZE RESIDENCE PERMANENT ADDRESS TEMPORARY ADDRESS PHONE NUMBER EMAIL 4208 VARMOOR
More information917 Camelia St. A0.0 PROJECT DATA PROJECT DESCRIPTION AREA SUMMARY. 917 Camelia St. Cover/Data
PROJECT DATA ADDRESS: 97 Camelia St Berkeley, CA www.studio.com ASSESSOR'S PARCEL NUMBER: OWNER: 00-50-009 Richard Spencer 0 8th Street Berkeley, CA AREA SUMMARY Parking Garage 9 sq.ft. Unit A ( new Live/Work)
More informationWaikoloa Homesites. Kohala Coast, HI. Outline Specifications. Prepared By: 16 December 15
Waikoloa Homesites Kohala Coast, HI Prepared By: Fritz Harris-Glade, NCARB, AIA FHG Architects AIA, LLC HG Construction Management, Inc. P. O. Box 4476 Kailua Kona, HI 96745 16 December 15 TMK : (3) 0-0-000:000
More information