1 TACOMA HOUSING AUTHORITY ADDENDUM NO. 1 PROJECT: WA: 5 - MLK New Look Apartments 1-16 ADDENDUM DATED: February 23, 2016 DISTRIBUTION: To all current Plan Holders-of-Record SUBJECT: Addendum No. 1 RFQ TO ALL PLANHOLDERS: Notice is hereby given to all RFQ Holders-of-Record on this date that the following ADDENDUM NUMBER 1 shall supplement and supersede (if in conflict) all documents previously issued for the information of the respondents to the RFQ. Questions: Q. When was New Look built? A Q. Are floor plans available electronically? A. Yes, they are posted on THA s website. Q. Does the scope of work include exterior and interior work? A. Yes. Q. Does the scope of work include exterior window replacement? A. No. Q. What is the demographic for New Look Apartments? A. The New Look Apartments are for seniors ages 55 and over with low income. Children are not allowed. Q. Will that change? A. No. Q. What is the condition of the roof? A. The roof is in good shape. There is door access. It is not ADA accessible. It is a possible location for a community garden. Q. What is planned for the former bank space? A. It will remain retail/commercial. Addendum No. 1 Page 1 of 3
2 TACOMA HOUSING AUTHORITY ADDENDUM NO. 1 Q. Will tenants be able to remain in their units during renovations? A. Yes. Q. Can tenants use the service corridor? A. No. Q. Is there stairway access to the upper floors of the building? A. Yes. Q. Has the building been previously refurbished? A. Not that we are aware of. Q. What are the plans for the courtyard? A. We would like to open the space all the way up to roof level. It will be necessary to repair the torn-out flooring at the exit doors and the resulting water damage. Q. Will the exterior work include drains? A. No. Q. Has the budget been finalized? A. Not yet. Q. Are pets allowed in the units? A. Yes. Q. Does the scope of work include the community rooms? A. Yes. There is only 1 community room in the building. Q. What about the water heaters? A. They will need to be replaced. The retail spaces have their own water heaters. Q. What about the laundry rooms? A. They need new finishes. Also need to move the recycle containers out of the hallways. Q. What needs to be done about ventilation? A. The current ventilation system sucks air out of units into the hallway and is very noisy. Need to look at reverse flow and reduced capacity. Addendum No. 1 Page 2 of 3
3 TACOMA HOUSING AUTHORITY ADDENDUM NO. 1 Q. Is there currently any discussion with the City regarding installing a crosswalk for disabled residents to ensure safe crossing to the parking lot across the street? A. No. Q. Do any exterior features need to be preserved for historical or community significance? A. No. Q. What changes are planned for indoor units? A. Planned changes include installing new cabinets that allow access to water heaters. No changes are planned for the wall structure. Q. What about ADA accessibility in unit bathrooms? A. Currently, ADA is on a tenant-by-tenant basis. The goal is to make every unit wheelchairaccessible. Replace any existing tubs with showers. Q. Will it be necessary to upgrade the security system? A. Yes, current security cameras are non-functioning. Q. Will the adjacent building be torn down? A. No, it is under separate ownership. Q. Is the building wood-frame? A. The structure is comprised of wood, concrete, and brick. Q. What about the Youth for Christ space? A. There are plans to renovate a portion of it. Size has not been determined yet. Clarification: Attachment A to the RFQ - AIA Contract B101 and A 201 was included as a sample only and does not need to be included in the SOQ. Comment: The Architect selected for this project will work with the Architect for the MLK Hilltop Master Planning project. PRE-SUBMITTAL CONFERENCE HELD ON FEBRUARY 2, :00 AM List of Attendees at Pre-Submittal Conference at Site on February 2, 2016, as well as the plan holders list as of February 23, 2016, are attached to this Addendum. END OF ADDENDUM NO. 1 Addendum No. 1 Page 3 of 3
4
5
6
7 Hilltop Lofts Rendering
8 Housing Sites and Potential Development Locations - Hilltop THA Parking lot New Look Parking lot Key Bank Property KSP Hilltop Lofts
9
10 TATLEY-GRUND, INC. Construction Repair Specialists 1115 N 97 th St. Seattle, WA (206) James E. Coulon Testing Technician Testing and Investigations Division Tatley-Grund, Inc Mobile (206) jcoulon@tatleygrund.com October 21, 2013 Tacoma Housing Authority 902 South L Street Tacoma, WA Phone: Fax: rschur@tacomahousing.org RE: New Look Apartments Investigation Dear Ms. Schur: Pursuant to Tatley-Grund s building envelope investigation at the New look Apartments, located at 1114 S. 11 th Street, in Tacoma, WA; please find the following brief narrative to describe our testing and results, followed by the attached photo report. Tatley-Grund technicians performed a building envelope survey which included topical observations and selective intrusive openings to document the current condition of the envelope components. The following elements were inspected during the survey: Exterior Cladding System Flashings Sealant Applications Decks and Deck Interfaces Windows and Doors Various Penetrations Through the Exterior Cladding Roof Components and Membrane Exterior Cladding System The cladding system at the New Look Apartments consists of two different materials. The first is a traditional direct-applied stucco drainage system. This covers three elevations of the building. North, East and West elevations. In this type of system, there is a secondary drainage plane or weather resistant barrier (building paper) behind the stucco. While the vast majority of all water will be shed off of the surface of the stucco wall, this drainage plane is designed to account for the small amount of water that may get past the stucco and carry it out of the cladding system either at a flashing detail or at the base of the wall. It is imperative that the drainage plane be complete and lapped in shingle-fashion and that drainage points are not sealed shut to prevent drainage of water from behind the stucco. With that being said, the stucco
11 Page 2 October 24, 2013 cladding does not have any separation within the floors or at through-wall openings, limiting the drainage capacity to the base of the walls. The lamina at the transitions to the window eyebrows was observed with failures in some locations and temporary sealant repairs in others along the west elevation. Three cutouts were made in the stucco cladding to observe the underlying conditions of the WRB and the sheathing. The weather resistant barrier (WRB), or building paper, installed beneath the stucco cladding was found to be a single layer of paper. Standards today recommend two layers of paper. The building sheathing is plywood. The sheathing was dry at two of the three cutouts made. A cutout was made between the first and second floor on the north elevation below the reglet flashing. The sheathing at this location was found to contain high moisture content 25.5 percent, (see report pg.7 slide 26 for details). Moisture content over 17 percent is elevated and is a sign that water is present. The butt joint of a reglet detail is typically not weatherproofed and is often a point for water to enter behind the cladding. Staining on the shim material for the reglet was observed. The WRB below the reglet was installed over the bottom flange, not tucked behind it, creating a mislap of the drainage plane. This allows water to get in between the WRB and the sheathing. Cracking of the stucco panels at the control joints was noted at all elevations where the stucco is applied. Movement or settling of the building is most likely continuing to occur as it s only twelve years old. The cladding on the south elevation, the courtyard, and the doghouses of the roof is vinyl lap siding installed with a single layer of building paper as the WRB. It appears that the stucco and the vinyl were installed at different times as the WRB is not a continuous layer beneath both claddings. This type of WRB installation leaves a weak point at the perimeter of the cladding, where the WRB starts and stops. The sheathing observed is exterior gypsum. Water staining within the west stairwell south interior wall and the east courtyard sheathing under the vinyl cladding where investigative openings were made suggests water intrusion through the CMU wall. This is caused by the missing coping metal flashing and a lack of correct weatherproofing as the claddings terminate. RECOMMENDATIONS: Although no water damage was found at any framing members, the presence of water, the current condition of the WRB, and observed cladding components suggest a complete overhaul of the cladding system should be considered in the future. Prolonging the current conditions with spot repairs may increase eventual costs as the components continue to deteriorate. Flashings Flashings were inspected during the survey, most were in good condition and functioning as intended. Missing coping flashing on the south elevation top of the parapet wall of the courtyard was a probably cause for excessive staining below. A determination of either treating the rust on the exposed structural beam or having to replace the beam must be made by a qualified engineer. The missing coping also allows water to penetrate through the CMU wall as evident by water damage in the
12 Page 3 October 24, 2013 gypsum in the west stairwell and in the courtyard with the presence of paint loosing adhesion and the efflorescence noted on the wall. Head flashings were not installed over windows or doors around the property. EIFS (Exterior Insulation Finish System) eyebrows cover the tops of the window heads. Signs of separation in the lamina at the transition from stucco-to-eifs were observed on the west elevation during the Boson s chair drops. Head flashings can be a designed drainage point for similar systems. Without them, any trapped water has to migrate down the wall to the next available drainage point. Unsealed or poorly interfaced vent hoods are suspected points for water to get behind the cladding. The temporary topical installations of hoods over these penetrations on the second floor showed they were able to either stop or slow the intrusion at these locations. A raw plywood collar was observed as an exhaust vent between the first and second floor on the west elevation. This needs to be removed and a metal flashing installed integrated into the cladding. Technicians call these fixes temporary because they are topical and not integrated into the cladding. RECOMMONDATIONS: Retain a structural engineer to assess the rusting beam on the south elevation. Integrate all flashing details into the drainage plane. Sealant Applications The sealant applications at windows, doors and various penetrations through the cladding were inspected. The sealant was found to be in very poor condition or not installed in all areas of the building. The termination of the stucco cladding as it interfaces the vinyl siding at two locations on the south elevation the full height of the building was observed unsealed. RECOMMENDATIONS: It is highly recommended that all the sealant on the building be removed and replaced with new silicone sealant. All joints need to be cleaned and prepped and properly tooled into place. This includes the window and door perimeter joints and the roof coping metal flashing as well. Decks and Deck Interfaces The decks of the building are located at the south elevation. The coatings on the decks are in need of a maintenance coat. Holes and door scrapes should be repaired before the maintenance coat is applied. RECOMMENDATIONS: The decks need to have a maintenance coat applied at all private decks and at the second floor common area also.
13 Page 4 October 24, 2013 Windows and Doors The windows and doors on the structure were in good condition and functioning as intended. RECOMMENDATIONS: Continue to monitor the conditions at the windows and doors, install new head flashings if you remove and replace the siding. Various Penetrations through the Exterior Cladding Vents, lights, hose bibs and other penetrations through the cladding were inspected during the survey. The sealant applications around the penetrations were not consistently sealed. The fire sprinkler escutcheons were penetrating through the vinyl cladding unsealed. RECOMMENDATIONS: Remove and replace old or failing sealant and replace with new silicone sealant. Roof Components and Membrane Tatley-Grund is not a roofing specialist and can only provide a cursory surface inspection, documenting current conditions and observations. Overall, the roof appeared to be in fair condition. Delamination of the roof membrane seams on the parapet wall was noted in multiple locations. Blisters within the membrane were observed at two different areas measuring two feet by three feet each. One blister was located in the north-west corner of the building and the other was at the southeast corner. RECOMMENDATIONS: Contact a licensed and bonded roofing contractor to repair the delamination on the parapet walls and inspect/repair the two blisters within the membrane. Assess the remaining life expectancy of the roofs membrane. If you have any questions regarding this report, please feel free to call me at Pricing for the repair recommendations listed above will be provided at your request. Please contact John Barrickman, Tatley-Grund project manager at (206) or by at jbarrickman@tatleygrund.com to request pricing. Regards, James E. Coulon Technician
14 1114 South 11 th Street Tacoma, WA North 97 th Street Seattle, WA Phone Fax
15 All Elevations 1 2 Tatley-Grund Was contracted to perform a general conditions survey on the building envelope of the New Look Apartments located at 1114 South 11th Street Tacoma, Washington, The building, built in 2001, is a four story building with 48 apartment units over commercial space on the ground level. The building is wood frame construction over a concrete foundation. 3 4 The south elevation is clad in vinyl siding over Concrete Masonry Unit (CMU) block. The east elevation is stucco clad. Vinyl framed windows with an EIFS brow. No head flashings were observed installed over the window openings. 1
16 South Elevation 5 6 The metal flashing that covers the parapet wall is joined by a method of folds called standing seam. The outboard edge is hooked to a clip strip and then fastened on the inboard side to the framing. Generally speaking, the majority of the fasteners were fully securing the metal to the building, however, some were not completely tightened. 7 8 Over the courtyard at the south elevation, the metal coping was not installed. The piece of coping was observed on the second floor courtyard deck. Heavy rust stains the beams at three floors and cracking in the CMU wall was observed. A piece of coping was removed to inspect the underlying conditions. Cedar sloping was observed, the roofing material was rolled under the cedar. Technicians were unable to see the termination of the roofing membrane-to-stucco cladding transition. 2
17 East Elevation 9 10 The third floor roof wraps around the east elevation. Pooling of water was observed on the roof membrane, suggesting a lack of slope to the drain. The lower roof has coping metal flashing installed. The termination of the flashing was in poor condition. The sealant has failed and the metal was easily pulled away The overflow scupper was clogged with organic debris. The perimeter sealant that weatherproofs the opening was losing adhesion with its substrate. The drain that services this portion of the roof has organic growth in and around it. 3
18 North Elevation Overview of the north elevation. Sealant pull tests were performed in three different locations around the site. This is where the sealant is pulled horizontally against itself until it breaks from itself or loses adhesion and pulls away from its substrate. In this case it passed by breaking on itself Overview of a fourth floor window opening. The perimeter sealant installed at this window was not tooled during installation. Properly tooling of a sealant joint is recommended to ensure full adhesion to the respective substrates. 4
19 West Elevation What appears to be a bullet hole in the aluminum facade was observed on the north elevation. The bullet does not appear to have penetrated through the stucco at this location Electrical conduit passes through the cladding for the Subway sign. Sealant installed at the penetration was poorly applied. 5
20 North Elevation The stucco cladding is a direct-applied traditional drainage system. Cutouts were made to inspect and document the underlying conditions. Plywood sheathing was observed with no staining and appeared dry in the opening made. One layer of WRB was noted and a six inch high piece of rubberized paper installed at the head of the window. No metal head flashing was observed Another cutout was made on the north elevation just below the fry reglet control joint. Technicians have seen in the past where similar details were a point for water to enter behind the cladding. At this location, the WRB is lapped over the reglet creating a miss-lap in the drainage plane. The drainage plane should be lapped shingle-fashion to move any water down and out from behind the cladding. 6
21 North Elevation Stains on the shim material shows water is penetrating through the butt joints of the fry reglet. A moisture meter reading was taken from the wood sheathing which registered 25.5% moisture content. A reading of 17% moisture content or higher indicates elevated moisture levels Overview of the west elevation. Arrow indicates the area of a cutout. Without any designed drainage points in the cladding above, technicians made this opening at the base of the wall, in-line with the window jambs above. A cutout was made in the stucco cladding to observe the conditions of the WRB and the sheathing. 7
22 West Elevation One layer of WRB paper was observed over the sheathing. The plywood sheathing was dry at this location and exhibited no signs of water damage. The paper was sealed and the stucco was replaced A raw piece of plywood is used for a vent collar on the second floor. The vent penetration should be correctly integrated into the drainage plane. This vent configuration was exclusive to this location. The plywood has been directly attached to the cladding without any obvious weatherproofing at the perimeter. 8
23 West Elevation Overview of a typical vent penetration on the third floor. The sealant that weatherproofs the perimeter of the vent has failed at multiple vent openings on the west elevation. This could be a point for water to enter behind the cladding A hood was installed over a opening by the onsite maintenance in an attempt to stop an ongoing water intrusion issue. The hood was installed topically and apparently stopped the intrusion. This type of installation is only a temporary fix, the vent hoods need to be integrated into the drainage plane shingle lap fashion behind the cladding. 9
24 West Elevation The sealant at the perimeter of the bedroom window was different that other sealant applications around the site. Obvious adhesion failures were noted. The sealant was pulled and technicians observed the material pulling away from it s substrates Apartment 313: A chair drop was performed on this window stack, on the west elevation, to inspect the exterior conditions. Another bullet hole was noted which has damaged the window frame. 10
25 Roof Elevation The roof membrane is a torch down roof. The membrane is showing wear from age. Large blisters were observed in two different locations on the roof elevation. Approximately 2 feet by 3 feet in size Overview of the west parapet wall. Organic growth was observed on the wall. Delamination of the seams was observed in multiple locations on the parapet walls of the roof membrane. 11
26 South Elevation Technicians made several openings at different locations within the vinyl cladding to document the underlying conditions. One layer of WRB was present at this location, two layers are preferred. Due to excessive moisture, the paper has bonded with the siding rendering the drainage plane ineffective. This is where a second layer of paper would maintain the shingled drainage plane Another area in the vinyl cladding was opened for inspection at the dividing wall. The paper beneath the opening was dry and in good condition. 12
27 West Elevation An investigative opening was made on the fourth floor west deck. Again only one layer of paper was observed. The WRB was cut and the sheathing exposed, staining on the exterior gypsum sheathing was noted suggesting water is penetrating the cladding from above The decks and their coatings were inspected during the survey. The coatings were in poor condition. Holes and tears in the coating were noted on the fourth floor west deck. The arrow indicates the tears where the door has sagged and the action of opening and closing is gouging the coating. 13
28 South Elevation A chair drop was performed at the south west corner of the building at the stucco-to-vinyl cladding transition. The sealant that covers the coping metal flashing was in poor condition There is a three-quarter inch gap between the J- channel of the stucco-to-vinyl casing that should be weatherproofed by a sealant joint. The joint continues down and is wide open the remainder of the length of the CMU wall. The WRB terminates at the vinyl siding. It should remain as one continuous piece behind the stucco cladding. Industry standards say that the WRB should lap itself two feet on vertical seams and six inches on horizontal seams. No lap was observed here. 14
29 West Elevation The missing coping metal has caused extensive staining to the CMU wall and the metal framing beams on the south elevation. This is not just surface rust on the beams of the third and second floors. The integrity of the beams should be in question after this extended exposure to moisture A joint within the CMU wall has been weatherproofed with sealant. The sealant has lost adhesion with the substrate and was observed failing sporadically throughout its entirety. 15
30 West Elevation Overview of the coping metal as it terminates against the neighboring building. A large gap under the flashing was noted. Spray foam was installed into the gap, however the foam is old and deteriorating and is allowing water to penetrate behind the stucco The weatherproofing of the joint between the two buildings was observed. The joint had been replaced sometime ago. The repair stopped short of completion. The top foot was not replaced. 16
31 West Elevation Water intrusion had been reported by the tenants to the managers of the property in four separate apartments. Apartment 211 was on that list. A controlled water spray test was performed at the window opening closest to the kitchen. Water stains were observed at the head of the frame Multiple tests were conducted at various locations but no increase in moisture at the interior was detected during the time that these tests were performed. Closer inspection of the EIFS (Exterior Insulation and Finish System) brow over the window opening shows that a sealant was applied to the seam that interfaces with the stucco cladding, 17
32 West Elevation Unit 212: Water staining was noted at numerous locations within the gypsum wallboard in the bedroom area of this studio apartment. A fifteen minute controlled spray test was performed and showed no increase in moisture or any water into the interior. Temporary repairs had been made to the exterior prior to testing. After the second test, which included the EIFS brow, an elevated reading from the moisture meter was noted The elevated reading was observed in the gypsum above the base molding below the window. No moisture in the carpet was ever observed during testing. The third test included the vent opening. At no time was water observed at the interior; however elevated moisture readings were noted. 18
33 West Elevation Unit 211: The bedroom window on the west elevation was tested during the survey. Moisture readings taken from the surrounding interior gypsum registered low moisture content. The first test was on the window and the perimeter sealant joint. After fifteen minutes of testing, no water was observed at the interior The second spray test included the EIFS brow, which technicians noted had a sealant joint applied at the EIFS brow-to-stucco transition. End of test moisture readings were taken in the gypsum at the head of the opening. High moisture content registered in the gypsum. No water was physically observed at the interior during or after the tests. 19
March 5, Tatley Grund, Inc. Building Repair Specialists 1115 No. 97 th Street Seattle, WA Stace Grund, President
March 5, 2015 Tatley Grund, Inc. Building Repair Specialists 1115 No. 97 th Street Seattle, WA 98103 Attn: Re: Stace Grund, President Renaissance Condominiums Seattle, WA Dear Mr. Grund: OAC Services,
More informationWeatherSmart Air Barrier Installation Guide
WeatherSmart Air Barrier Installation Guide 1 The intent of this document is to provide a guide for the installation of WeatherSmart as both a Weather Resistive Barrier (W.R.B.) and an Air Barrier Material
More informationINSTALLING WATER-RESISTIVE BARRIERS & FLASHING
INSTALLING WATER-RESISTIVE BARRIERS & FLASHING IN A TWO-LAYER STUCCO APPLICATION Fortifiber Building Systems Group provides this guide to assist installers by demonstrating a two-layer installation of
More informationPROPERTY PRESERVATION AND CAPITAL PLANNING
PROPERTY PRESERVATION AND CAPITAL PLANNING Overview What am I looking for Remaining Useful Life Estimating Planning TERMINOLOGY Shake Siding Service Head Barge Board Soffit / Overhang Belly Band Knee Brace
More informationFirstEnergy Program Overview
FirstEnergy Program Overview Builder incentives $400 per unit + $0.10/kWh in projected savings Eligibility Located in service area of a FirstEnergy Utility Certificate of Occupancy Dates: FirstEnergy Ohio
More informationStucco Moisture Inspection Report
Website:www.ibgoodinspector.com E-Mail:support@ibgoodinspector.com January 11, 2006 Stucco Moisture Inspection Report Property Address 123 Our Street OurTown, USA 12345 Report Ordered By: Mr. & Mrs. Client
More informationHenri Fennell, CSI/CDT ABX 2015
Henri Fennell, CSI/CDT ABX 2015 Henri is an architect and building envelope specialist with over forty years of experience in the construction industry. He was a pioneer in the solar industry, introduced
More informationLimited Leak Assessment
Website:www.moistureconsultantsinc.com E-Mail:support@moistureconsultantsinc.com December 2th, 2005 Limited Leak Assessment Property Address US Naval Facility Building 484 Panama City Beach, Florida Report
More informationChapter 2 Understanding The Problem
Chapter 2 Understanding The Problem What Causes Most Of The Problems With Stucco? EIFS was originally intended to seal and insulate the exterior of the home from the elements. Problems occur when poorly
More informationFMA / AAMA / WDMA Installation Committee Update. Jim Katsaros / DuPont Building Innovations FMA Installation Committee April 24, 2012
FMA / AAMA / WDMA Installation Committee Update Jim Katsaros / DuPont Building Innovations FMA Installation Committee April 24, 2012 Topics for discussion. Review & Update on FMA/AAMA/WDMA Window & Door
More informationPrimary Concerns and Defects
Primary Concerns and Defects Primary Concerns and Defects: Home Inspector Observations: Where to Look. What to Look For. What Observed condition may mean. Primary Concerns The points to be inspected per
More informationGLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN
GLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN TM June 1, 2002 TOPIC: Exterior Coverings This is the sixth in a series of technical bulletins in which an over-all examination of the home will be discussed
More informationBuilding Construction and Water Intrusion
Building Construction and Water Intrusion RAY CHOY-MARSHALL GOVAN ASSOCIATES an architectural corporation ray_choy-marshall@sbcglobal.net 2930 camino diablo, suite 210, walnut creek, ca 94597 2004 Design
More informationRevised January buildingscience.com. Water Management Details. Housewraps/Flashings/Windows buildingscience.com
Revised January 2007 Housewraps/Flashings/Windows BSP-020: for Residential Buildings Table of Contents Introduction... 4 Water Management Concept...4 Risk Factors... 4 Building Paper/Housewraps as the
More informationAqua Coast Engineering
Aqua Coast Engineering Ltd. P.O. Box 1367 Station A Delta, B.C. V4M 3Y8 Tel: (604)948-0958 Fax: 604)948-0959 September 1, 2011 Matthew Cheng File#:11145 Matthew Cheng Architect Inc. Fax: 604-731-3908 Unit
More informationMagnum Board Coatings
Master Wall Mesh and Base Coat Plastic Control Joint Accessory, Plastic Components 22027-16 or equal. See notes for placement recommendations Notes: Control joints are required and should be located by
More informationQuality Inspection 8618 London Heights San Antonio, TX Phone: (210)
Quality Inspection 8618 London Heights San Antonio, TX 78254 Phone: (210) 240-0476 PRE DRYWALL INSPECTION REPORT Prepared For: DELETED (Name of Client) Concerning: DELETED, San Antonio, TX 78258 (Address
More informationEXTERIOR SIDING CONDITION SURVEY
EXTERIOR SIDING CONDITION SURVEY FOR FARRWOOD 2 CONDOMINIUMS 49-176 FARRWOOD DRIVE HAVERHILL, MA APRIL 2016 c/o PROPERTY MANAGEMENT OF ANDOVER, INC. P.O. BOX 488 ANDOVER, MA 01810 213 WEST STREET, MILFORD,
More informationWrapShield SA Brick Tie Penetration
Brick Tie Penetration Outboard Vapor - Pemeable Insulation WrapShield SA Self-adhered WRB/AB field membrane Brick Tie must be Flush and compressed against Membrane with no prong penetrations Gasketed Fastener
More informationGAF EnergyGuard Polyiso Wall Sheathing
From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include:
More informationNational Property Inspections
Monday, August 22, 2011 Inspector Joe Smith 548-254-3658 Page 1 of 33 GENERAL INFORMATION GENERAL CONDITIONS AT TIME OF INSPECTION : No Property Occupied : Property Faces : North South East þ West Year(s)
More informationDuPont Tyvek Wall Underlay Install Guide
DuPont Tyvek Wall Underlay Install Guide (For Residential & Light Commercial Buildings) Acceptable Solution to NZBC E2/AS1 New Zealand As at 1/4/15 Version 2 Subject to change without notice DuPont Tyvek
More informationMoonlight Architecture, Inc. Architecture Interior Design Site Planning
Moonlight Architecture, Inc. Architecture Interior Design Site Planning 22 May 2018 18057 Mr. Michael J. Petit de Mange, County Administrator Kent County Levy Court 555 Bay Road Dover, DE 19901 RE: Facilities
More informationHIDDEN HOLES IN WOOD FRAMED BALCONY WATERPROOFING
HIDDEN HOLES IN WOOD FRAMED BALCONY WATERPROOFING ROCCO ROMERO, RA WISS, JANNEY, ELSTNER ASSOCIATES, INC. 960 South Harney St., Seattle, Washington 98108 Phone: 206-622-1441 Fax: 206-622-0701 E-mail: rromero@wje.com
More informationSC-01 Cross-Section. Cement Board Substrate Master Wall Mesh and Base Coat Superior Finish
Master Wall Mesh and Base Coat Plastic Control Joint Accessory, Plastic Components 22027-16 or equal. See notes for placement recommendations Notes: Control joints are required and should be located by
More informationInsulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS
Insulation First Revison October 2016 DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS 1. General Information This Guide describes the use of Kingspan GreenGuard DC14 Drainage
More informationDistances are not shown to scale. Existing porch. Community. Building. Distances are not shown to scale
patio and deck 00 Building Two story Four-plex Entrance 0 0 00 Building Single Story Duplex 0 patio Contact Information: Owner: Housing Authority of Yamhill County, NE Dunn Place, McMinnville, OR 9. Contact:
More informationOwners of Strata #2720 c/o
667 Beaver Lake Rd. (250) 479-8050 Victoria BC V8Z-5N9 June 29, 2009 Owners of Strata #2720 c/o Roger Taylor #417 545 Manchester Rd. Victoria, BC Attention: Roger Taylor Dear: Owners of Strata #2720, Re:
More informationIntroduction Observations
Architecture Roof Consulting Construction Technology AA C000932 601 North Fern Creek Avenue Suite 100 Orlando, Florida 32803-4899 (407) 896-7875 FAX (407) 898-6043 October 12, 2013 Mr. David Martin, Project
More informationTOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION
TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION Town of Hague Building Inspector: Dale Wagner Home #: 306-225-2265 Cell #: 306-241-4741 Fill all part of the permit application including the date and signature.
More informationInspection Report. Property Address:
Inspection Report provided by: Safe Side Home Inspection Inspector: Corey Stuart TN License # 778 434 Margaret Circle McMinnville, TN 37110 safesideinspection@blomand.net Property Address: 1234 Anywhere
More informationINSPECTION TYPE EIFS system, Visual, Tramex & Delmhorst probe moisture readings
FINEGAN INSPECTION SERVICES, INC. 27 Laurelwood Drive Milford Ohio, 45150 513 683-0733 RESIDENCE LOCATION INSPECTION TYPE EIFS system, Visual, Tramex & Delmhorst probe moisture readings OVERVIEW The report
More information7 Finishes / Exterior
7 Finishes / Exterior 7.1 Siding is bowed or wavy. Siding shall be installed to accommodate thermal movement and anticipated shrinkage of the structure to which it is attached. Siding shall be generally
More informationSUMMARY 1234 Main St.Loudon TN Buyer Name 08/28/2018 9:00AM
SUMMARY 1234 Main St.Loudon TN 37774 Buyer Name 08/28/2018 9:00AM Dusty Jameson TN Home Inspector License #00123, TN WDI License #104158 Inspector Cluseau's Home Inspection Service 865-691-6158 dustyjameson@gmail.com
More informationPROFESSIONAL ENGINEERING INSPECTIONS, INC. P. O. BOX HOUSTON, TEXAS (713)
PROFESSIONAL ENGINEERING INSPECTIONS, INC. P. O. BOX 271492 HOUSTON, TEXAS 77277 http://www.profengineering.com (713) 664-1264 June 19, 2000 Mr. Samuel Underdog 329 Castle Dr. Houston TX 77018 Dear Mr.
More informationBUILDING ENVELOPE DESIGN GUIDELINES APPENDIX 3
PART 1 GENERAL BUILDING ENVELOPE DESIGN GUIDELINES 1.01 INTRODUCTION A. This is a guideline on the Owner s minimum standards for: 1. Masonry Division 04 2. Copings Division 04 or 07 3. Cavity wall flashings
More informationGensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION
SECTION 072700 VAPOR PERMEABLE AIR BARRIER LIQUID MEMBRANE PART 1 GENERAL 1.1 GENERAL REQUIREMENTS A. The Work of this Section, as shown or specified, shall be in accordance with the requirements of the
More informationPella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...
SECTION DIRECTORY General Information Introduction... V250-ID-886 Installation Accessories and Applications... V250-ID-886 Typical Sealant Placement Details... V250-ID-887 Fin Installation Details Wood
More informationDuPont. Tyvek Sheathing Membrane Installation Guidelines. Version 2. Canadian Version
DuPont Tyvek Sheathing Membrane Installation Guidelines Helping you get the job done right Canadian Version Version 2 Table of Contents Applicable Products...2 Required Materials...2 Code Requirements...3
More informationDow Corning Silicone Air Barrier System. A more. energy-efficient. shade. green
Silicone Air Barrier System of shade energy-efficient A more green Air and Moisture Protection for More Energy-Efficient Buildings Meeting regulatory requirements for energy efficiency is a significant
More informationAPPENDIX 3C DOMINION HOTEL SPECIFICATIONS
APPENDIX 3C DOMINION HOTEL SPECIFICATIONS 1. GENERAL 1.1 Refer to Section 2.1 of Schedule 3 [Design and Construction Specifications] regarding compliance with Schedule 3 and this Building Specification.
More informationForensics Engineering 8th Congress Forging Forensic Frontiers November 29 December 2, 2018, Austin, TX
This paper was published at the Forensic Engineering 8th Congress, held November 29-December 2, 2018 in Austin, TX. The published version of this paper is available for purchase and download at: https://ascelibrary.org/doi/book/10.1061/9780784482018
More informationSenturion TM I Wall System
Senturion TM I Wall System TYPICAL DETAILS 1017662 1. Senturion I Wall System Application (Plan VIew) 2. Senturion I Wall System Application (Isometric View) 3. Aesthetic Groove (Plan View) 4. Insulation
More informationWork Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free
/ / Paperport 2000 official estimating report Work Write Up / Specification of Repairs Toll Free 1-877-932-7177 Clients Name. GREAT CLIENT Property Address. NUMBER ONE GOOD ROAD METRO, VA 20000 Primary
More informationCommercial Flashing Details
This technical note illustrates many of the most common flashing details for commercial buildings. The purpose for flashing is to direct moisture to the exterior and in so doing, prevent moisture from
More informationProperty Inspection Checklist
Property Inspection Checklist Use a checklist like this to make sure that you are looking at all parts of the house. Check off those items that are in good condition and make notes about those that are
More informationR E S I D E N T I A L B U I L D E R S R E F E R E N C E G U I D E
DRYVIT SYSTEMS CANADA DSC504 R E S I D E N T I A L B U I L D E R S R E F E R E N C E G U I D E BUILDING SUCCESSFULLY WITH DRYVIT OUTSULATION RESIDENTIAL SYSTEMS INTRODUCTION Building Successfully with
More informationU.S. EDITION RESIDENTIAL CONSTRUCTION DETAILS SAMPLE. A visual guide to construction detailing. Emma Walshaw
RESIDENTIAL CONSTRUCTION DETAILS U.S. EDITION A visual guide to construction detailing Emma Walshaw Contents INTRODUCTION 4 PRINCIPLES OF CONSTRUCTION DETAILING 6 FOUNDATIONS 9 PRINCIPLES OF FOUNDATION
More informationSECTION 07530CP EPDM MEMBRANE ROOFING
PART 1 GENERAL 1.1 SUMMARY SECTION 07530CP EPDM MEMBRANE ROOFING A. Section includes: 1. Adhered membrane roofing and flashing 2. Mechanically fastened roof insulation 3. Walkway pads 1.2 ARCHITECTURAL
More informationExterior structures (fences, sheds, decks, retaining walls, detached garages) in good condition, no evidence of termite damage or rotted wood
Please Note: This checklist should not be relied upon as a home inspection report, nor should it be considered a substitute for a home inspection. This list is representative, but NOT exhaustive. If you
More informationSRP-AirOutshield UV Issued:
SECTION 07276: SRP-AirOutshield UV Ultra Violet (UV) resistant, Vapour Permeable Air Barrier Underlayment and Sheathing Membrane Guide Specification This specification is a guide only and may need editing
More informationPROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS DAVIS, CALIFORNIA
The following standard specification is intended to be edited according to the specifics of the project. Brackets [ ] and areas shaded in gray [e.g. format] indicate requirements that are optional depending
More informationSECTION FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER
PART 1 - GENERAL 1.01 SUMMARY SECTION 07 65 00 FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER A. Section includes through wall masonry flashing system components for installation over sheathing where spray
More informationFor The Home Of: Mr. & Mrs. Sam A. Sample 123 Main Street Our Town, USA 12345
For The Home Of: Mr. & Mrs. 123 Main Street Our Town, USA 12345 Project Information PROPERTY INFORMATION INSPECTION INFORMATION Owners Mr. Owner Rust ID Number 12345678 Property Address Claims Form ID
More informationDIVISION 7 THERMAL AND MOISTURE PROTECTION
DIVISION 7 THERMAL AND MOISTURE PROTECTION UCSC Campus Standards Handbook Waterproofing Standards 07100 1 SECTION 07100: WATERPROOFING STANDARDS A. Guarantee 1. Provide a guarantee on Contractor's letterhead
More informationPrepared By. Accent Building Sciences Inc. For
ROOF LEAK INVESTIGATION & CONDITION ASSESSMENT REPORT For Toronto, Ontario Prepared By Accent Building Sciences Inc. For Client# 40105 Date: November 11, 2003 November 2003 Roof Leak Investigations & Condition
More informationSECTION SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT
SECTION 07 30 05.01 SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT SPEC WRITERS NOTE: This specification includes materials and installation procedures for SlopeShield SA Self-Adhered Water-Resistive Vapor
More informationCounty of Santa Barbara, California Facility Condition Assessment Total: $238,124. Appendix 1 Probable Cost Estimates Detail
Project No.:P03000.001 Building Number: P03000-Lompoc County Offices Grounds Project Description: Mill and Overlay with some Partial Depth Patching Background: The site comprises asphalt pavement for the
More informationRevealShield SA Penetrations
Penetrations For Larger Penetrations, use VaproLiqui-Flash tooled at least 2" onto the face and 2" out along all sides of the penetration Apply sufficient Dow 758 Sealant to completely seal fastener penetrations
More information2019 IAQA Annual Meeting
Daniel Stih, CMC. CIEC Healthy Living Spaces Stanley Yeskolski CIEC, CMC Investigative Inspection Services Inc. 2 Purpose The presentation will provide a over view of: Installation Details Problem Areas
More information2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:
SECTION 07651 FLEXIBLE COPPER SHEET FLASHINGS Advanced Building Products, Inc. manufacturer many types of flexible copper sheet flashings. Due to their ductility, high tensile strength, and resistance
More informationSUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:
IRC CODE UPDATES TO: RESIDENTIAL BUILDING CONTRACTORS FROM: GARY STABER, BUILDING OFFICIAL SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE: 6/1/2003 INTERNATIONAL RESIDENTIAL CODE (IRC) APPLICABILITY:
More informationBULLETIN FROM THE FIRST COAST CHAPTER ICC~BOAF
FIRST COAST CHAPTER INTERNATIONAL CODE COUNCIL (ICC) AND BUILDING OFFICIALS ASSOCIATION OF FLORIDA, INC. (BOAF) SERVING BAKER, BRADFORD, CLAY, DUVAL, NASSAU, PUTNAM, ST. JOHNS & UNION COUNTIES BULLETIN
More informationSenturion TM III Wall System
Senturion TM III Wall System TYPICAL DETAILS 1017666 1. Senturion III Wall System Application (Plan VIew) 2. Senturion III Wall System Application (Isometric View) 3. Aesthetic Groove (Plan VIew) 4. Insulation
More informationMoisture Free Inspection Report
Moisture Free Inspection Report For the Property Located At: 123 Our Street ThisTown, USA 12345 Report Prepared For: Mr. & Mrs. Client 4255 Old Danielsville Rd.,Athens, GA 30601 PH: 706-248-3596 : HomeandStuccoInspectionsofGa.com
More informationDIVISION 07 THERMAL AND MOISTURE PROTECTION ROOFING
07 00 00 PART 1 - GENERAL 1.01 DESIGN CRITERIA A. Preferred roofing types include Membrane, Metal, and Composition Shingles. 1. Membrane roofing is preferred for flat roof decks. 2. Use of asphalt-based
More informationSTRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details
STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C Stratum Guard I and II System Installation Details Stratum Guard I and II DETAIL Table of Contents NOTE SG.0.0.01 SG.0.0.02
More informationPebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details
Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier Typical Details (THIS PAGE INTENTIONALLY LEFT BLANK Pebbletex Wall System Class PB Exterior Insulation
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification
More informationRain. Building Science. Rain is the largest source of moisture We need better control for better insulation and airtightness Rain penetration control
Rain Control Layer Air Control Layer Vapor Control Layer Thermal Control Layer Rain Control 1 Rain Control 2 Rain Rain Control Rain is the largest source of moisture We need better control for better insulation
More informationSiding and Soffit Installation Guidelines
Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field
More informationSiding and Soffit Installation Guidelines
Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field
More informationCascade Thermal Imaging, Inc. ~ Infrared Imaging The Non-Invasive Truth ~ Thermography Report
TM Thermography Report Completed for: Mr. John Smith 2242 Greenwood Ave - Seattle, WA 98102 Thermography date: 1-26 & 1-29-16 Outdoor temperature: 54 F Indoor temperature: 68 F Temp diff In-Out Δ T : 14
More informationBUILDING EXTERIOR SHELL TRAINING
BUILDING EXTERIOR SHELL TRAINING Course Handout Part 1 Background and Insurance Issues (19min) Causes of Building Exterior Shell Problems Bad Design Poor Planning Failure to Follow Manufacturer s Recommendations
More informationINNISGLEN CONDOMINIUMS, BELLEVUE, WASHINGTON LIMITED ROOF EXAMINATION EXECUTIVE SUMMARY
626 120 th Ave NE suite B101 Bellevue WA 98005 o: 425 455 2046 / f: 425 455 2069 dimensionalbc.com GSG Group Incorporated 144 Railroad Ave. #101 Edmonds, WA 98020 Attention: RE. Mr. Bruce Goodson, LEED
More informationStucco Moisture Testing Report
Stucco Moisture Testing Report 0 Property Address: ABC St. Anywhere, LA Ordered by: Seller or Purchaser Inspection Connection, Egret St., Covington, LA 0 Bus: 9-- Cell: (9) - Email: chrissavoie@bellsouth.net
More informationExterior Stucco and Siding Installation
Exterior Stucco and Siding Installation CITY OF NEWARK, CALIFORNIA BUILDING INSPECTION DIVISION 37101 Newark Boulevard, Newark, CA 94560-3796 510-578-4261 Fax 510-578-4307 e-mail: building.inspection@newark.org
More informationUniversity of New Hampshire Scholars' Repository
University of New Hampshire University of New Hampshire Scholars' Repository Division 07 Thermal and Moisture Protection Chapter 5 Technical Construction and Renovation Standards 1-25-2013 075423 - TPO
More informationNew Home Warranty Handbook
New Home Warranty Handbook Cabinets CB 1 Warping of doors and drawer faces should not exceed ¼ inch. Warping is measured from the face of the frame to the point of maximum warpage, with the door or drawer
More informationA.ENVELOPE AIR SEALING
(Page 1 of 4) Note: The Energy Efficiency Standards Section 110.7 requires that all joints, penetrations and other openings in the building envelope that are potential sources of air leakage shall be caulked,
More informationBUILDING SUCCESSFULLY WITH DRYVIT RESIDENTIAL SYSTEMS.
BUILDING SUCCESSFULLY WITH DRYVIT RESIDENTIAL SYSTEMS. DS504 THE FOLLOWING IS A LIST OF MAJOR CONSIDERATIONS THAT WILL HELP ENSURE A QUALITY DRYVIT INSTALLATION. SUBSTRATES (INSPECTION/WALK-AROUND) Prior
More informationTEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up
TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM Form 15 Work Write-Up Owner-Builder Applicant Owner-Builder Co-Applicant Physical Address: City,
More informationSECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS
SECTION 075423 - THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including Division 00 Bidding Requirements and other Division
More information3. Aesthetic Groove. 5. Window Head (Flush) 6. Window Head (Recessed) 7. Window Jamb Detail (Flush) 8. Window Jamb Detail (Recessed)
TYPICAL DETAILS Pebbletex-D10 System 1. Pebbletex-D10 Application (Plan VIew) 2. Pebbletex-D10 Design (Isometric View) 3. Aesthetic Groove 4. Insulation Boards / Reinforcing Mesh Application at Openings
More informationHow-to: Commissioning Design Reviews for the Building Envelope
AABC Commissioning Group AIA Provider Number 50111116 How-to: Commissioning Design Reviews for the Building Envelope Course Number: CXENERGY1625 Stevan Vinci, BECxP, LEED AP, Morrison Hershfield Maurya
More informationAcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details
Typical Details AcroWall-ES System Class PB Exterior Insulation and Finish System providing a primary moisture barrier 1. Typical AcroWall-ES System Application 2. Typical Aesthetic Reveal 3. Typical Window
More informationCHECKLIST Inspecting a Garage
CHECKLIST Inspecting a Garage By Ben Gromicko This section deals with the details of the garage or carport inspection that may be performed. At the end of this section, you shall be able to: describe the
More informationEMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire
EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire Additional Instructions and Clarifications 1. Please review ARC 4496 before beginning the project identification
More informationItem 2.3 Unit pricing GC to provide a square foot unit cost for material and labor to replace plywood decking beneath new concrete walkway slab.
Willow Glen Housing Repairs Project #9-59 Addendum Item. Change to bid date The bid date will be extended to March 8, 09, :00pm at the Housing Authority of Columbus Central Office,000 Wynnton Road Columbus,
More informationPerimeter Relief and Control Joints in Fire-Rated Gypsum Board
Perimeter Relief and Control Joints in Fire-Rated Gypsum Board In multi-family residential construction, involving fire-rated assemblies stress relief in the firerated assemblies is important, but often
More informationApplication Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS
Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS CHECKLIST PRIOR TO THE INSTALLATION OF BACKSTOP NT - SMOOTH AND TEXTURE Project Conditions Maximum storage
More informationExisting Site Aerial Frederick High School Feasibility Study September 5, 2012
Existing Site Aerial Building Developmental History 1981 1966 1939 1977 1978 1955 1966 Exterior Roof: Most of existing roof has multi ply built up roofing. Some areas have gravel ballast, others have cap
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used
More informationROME ART AND COMMUNITY CENTER
ROME ART AND COMMUNITY CENTER 308 W. Bloomfield St. Rome, NY 13440 INSULATION AND SLATE ROOFING REPAIRS SCOPE OF WORK: A. SPRAY FOAM INSULATE ATTIC AREA B. FRONT ROOF REPAIR C. REAR ROOF REPAIRS D. INTERIOR
More informationDr. Edward Livingston Trudeau Building. 118 Main Street, Saranac Lake, NY. Building Systems Report. June 24, 2018
G2 Gordon + Gordon Architecture. LLC Dr. Edward Livingston Trudeau Building 118 Main Street, Saranac Lake, NY Building Systems Report June 24, 2018 Harry Gordon, FAIA 164 Otter Slide Road Saranac Lake
More informationFACE CFP - HORIZONTAL PANELS - OPTION 'B'
- Vertical Transitions 12F - H10.3 VHB TAPE 5.000" 127.0mm 5" FORMED TRANSITION STRIP w/ FLAT FACE CFP - - OPTION 'B' H10.3 CONCEALED FASTENED Panel Index 12F - H0 BASE DETAILS JOINT DETAIL PARAPET ROOF
More informationSUMMARY 792 Youngfield Ct., Lakewood CO Frank Oz January 13, 2018
SUMMARY 792 Youngfield Ct., Lakewood CO 80228 Frank Oz January 13, 2018 Christopher Grabbe internachi Certified Professional Inspector FirePower Inspections 7204645889 info@firepowerinspections.com 2.1.1
More informationBeginning of the Course
Beginning of the Course Topics we will Cover What is Stucco? What does InterNACHI require? How to Identify Stucco Type. Primary Concerns Related to Stucco. How to Inspect during a Home Inspection. What
More informationMargaret Batts Tobin Laboratory
Roof Evaluation of Margaret Batts Tobin Laboratory The University of Texas At San Antonio Performed for UTSA Zero/Six Consulting, LLC 8423 Stewart Road Galveston, Texas 77554 409 740 0090 voice Table of
More information