The following additional instructions shall apply to and govern the Contract Documents.

Size: px
Start display at page:

Download "The following additional instructions shall apply to and govern the Contract Documents."

Transcription

1 March 18, 2014 Addendum #1 E.C. St-Michel Building Envelope Upgrade New Liskeard, Ontario Project # The following additional instructions shall apply to and govern the Contract Documents. Item #1 Reference: Specifications Document Appendix C : Alternative Prices Additional Information Replace existing document with revised attached document. (1 page) Item #2 Reference: Specifications Additional Information Add the attached Document Appendix D: Add-In / Take-out Prices to the specifications. Provide Add-In price as noted. This information must be submitted with the Tender Form at the time of Bid Closing. Item #3 Reference: Specifications Document Designated Substance Report Additional Information Replace the existing report with the attached updated report. (39 pages) Vancouver Toronto Ottawa Timmins Thunder Bay Cornwall Sudbury PBK Architects Inc. 172 Algonquin Blvd. East, Timmins, ON, Canada, P4N 1A9 Telephone: (705) ~ Fax: (705) ~

2 Item #4 Reference: Specifications Details D9, D14, D19 Additional Information Contractor to refer to details D9, D14, D19 and allow for mineral fibre wool insulation to fill the cavity of the new parapet wall construction. Item #5 Reference: Specifications Detail D14 Additional Information Contractor to refer to detail D14 and add note Fill existing deck flutes with mineral fibre batt insulation as shown. Item #6 Reference: Specifications Document Construction Assembly Schedule Wall Types Clarification Walls Types W1 and W3 to be revised as follows: W1: 19x64mm prefinished fiber cement vertical batten board as 400mm O.C. (at steel studs) Prefinished fiber cement board as specified 25mm Vertical Z Girt as 400mm O.C. 100mm fiberglass 400mm horizontally (at steel studs) and 400mm O.C. vertically 115mm sprayed polyurethane foam insulation (RSi: 5.15) 13mm denglass gold sheathing 152mm wind load bearing steel 400mm O.C. 16mm type x gypsum board W3: Prefinished Lap siding as specified 25mm Vertical Z Girt as 400mm O.C. 100mm fiberglass 400mm horizontally and 600mm O.C. vertically on 184mm x thickness to suit continuous horizontal wood blocking 115mm sprayed polyurethane foam insulation (RSi: 5.15) Vancouver Toronto Ottawa Timmins Thunder Bay Cornwall Sudbury PBK Architects Inc. 172 Algonquin Blvd. East, Timmins, ON, Canada, P4N 1A9 Telephone: (705) ~ Fax: (705) ~

3 13mm denglass gold sheathing 152mm wind load bearing steel 400mm O.C. 16mm type X gypsum board Item #7 Reference: Specifications Section Spray-in-Place Urethane Insulation Clarification Replace the existing specification section with the revised section attached. (5 pages) Item #8 Reference: Specifications Section PVC Roofing 2.6 Walkway Protection Additional Information.1 Crossgrip Walkway In all instances, remove reference to roof Walkway protection (Crossgrip Walkway). This product is no longer required for the project. Item #9 Reference: Specifications Division 09 - Finishes Room Finish Schedule Clarification Replace existing document with revised Room Finish Schedule R1. (6 pages) Item #10 Reference: Drawings A1.1 Partial Demolition Floor Plans, Demolition Notes and Legend A1.2 Partial Floor Plans, Key Plan, Notes, General Notes and Legend Clarification Refer to the attached revised Notes Legend ADD1.1 and ADD 1.2. Vancouver Toronto Ottawa Timmins Thunder Bay Cornwall Sudbury PBK Architects Inc. 172 Algonquin Blvd. East, Timmins, ON, Canada, P4N 1A9 Telephone: (705) ~ Fax: (705) ~

4 Item #11 Reference: Drawings A1.2 Partial Floor Plans, Key Plan, Notes, General Notes and Legend General Notes Clarification Revise General Note #20 to read: Contractor to allow for 10 boxes of replacement ceiling tile to match existing within areas of renovation. Remaining tile upon completion of work is to be turned over to Owner for future use. Item #12 Reference: Drawings A1.1 Partial Demolition Floor Plans, Demolition Notes and Legend Drawing #5/A1.2 Partial Demolition Plan at Classrooms Clarification Revise note within Corridor #130 to read: Contractor to limit slab breakage to a minimum to allow for new washroom plumbing installations. Provide new VCT floor finish c/w rubber base as specified within Corridor #130. Extent of new VCT floor finish to be in line with west wall of Corridor #118. Provide good transition between new and existing Corridor VCT floor finishes. Item #13 Reference: Drawings A1.2 Partial Floor Plans, Key Plan, Notes, General Notes and Legend Drawing #5/A1.2 Partial Floor Plan at Classrooms Clarification Contractor to note there will be no children s cubbies within Classroom #132. Provide new whiteboard and tackboard arrangement to match south wall in Classroom #131. Vancouver Toronto Ottawa Timmins Thunder Bay Cornwall Sudbury PBK Architects Inc. 172 Algonquin Blvd. East, Timmins, ON, Canada, P4N 1A9 Telephone: (705) ~ Fax: (705) ~

5 Item #14 Reference: Drawings A1.2 Partial Floor Plans, Key Plan, Notes, General Notes and Legend Drawing #5/A1.2 Partial Floor Plan at Classrooms Clarification Remove specified porcelain floor tile finish within Classroom #132 and replace with VCT floor finish as specified. Item #15 Reference: Drawings A1.2 Partial Floor Plans, Key Plan, Notes, General Notes and Legend Drawing #5/A1.2 Partial Floor Plan at Classrooms Additional Information Contractor to provide 16 (sixteen) lockers, Type A as specified, in Corridor space along wall across from door #120. Item #16 Reference: Drawings A1.2 Partial Floor Plans, Key Plan, Notes, General Notes and Legend Drawing #5/A1.2 Partial Floor Plan at Classrooms Additional Information Remove new gypsum board chase within south-east corner of the room. Within classroom #108, Contractor to provide 64mm metal stud wall against existing west classroom wall. New stud partition wall to extend to underside of deck. Provide 16mm type x gypsum board finish c/w bullnose corners and gypsum board returns at existing door frame to remain. Contractor to extend/relocate services as required along this wall to suit new conditions. Item #17 Reference: Drawings A1.2 Partial Floor Plans, Key Plan, Notes, General Notes and Legend Drawing #5/A1.2 Partial Floor Plan at Classrooms Additional Information Within classroom #108, Contractor to allow for 92mm metal stud chase behind door #112 c/w metal access door based on 12 x12 UA Series by MIFAB. Contractor to provide additional 92mm metal Vancouver Toronto Ottawa Timmins Thunder Bay Cornwall Sudbury PBK Architects Inc. 172 Algonquin Blvd. East, Timmins, ON, Canada, P4N 1A9 Telephone: (705) ~ Fax: (705) ~

6 stud wall framing c/w 16mm type X wall for the extent of new cubbies to conceal existing radiator supply and return lines. Provide wood blocking and additional support as shown on drawings and as required. Exact location of wall to be coordinated on site with millwork construction requirements. Item #18 Reference: Drawings A1.2 Partial Floor Plans, Key Plan, Notes, General Notes and Legend Drawing #5/A1.2 Partial Floor Plan at Classrooms Clarification Within Classroom #111, note N37 to be revised to N33. Item #19 Reference: Drawings A1.2 Partial Floor Plans, Key Plan, Notes, General Notes and Legend Drawing #5/A1.2 Partial Floor Plan at Classrooms Clarification Within Classroom #128, note N33 to be revised to N34. Item #20 Reference: Drawings A1.2 Partial Floor Plans, Key Plan, Notes, General Notes and Legend Drawing #5/A1.2 Partial Floor Plan at Classrooms Clarification Within Classroom #110, note N2 along interior wall closet to be revised to N5. Item #21 Reference: Drawings A1.2 Partial Floor Plans, Key Plan, Notes, General Notes and Legend Drawing #4/A1.2 Partial Floor Plan at Second Floor Seminar Room Clarification Contractor to remove all lockers specified within room #208 Seminar Room. No work is to take place within this room. Vancouver Toronto Ottawa Timmins Thunder Bay Cornwall Sudbury PBK Architects Inc. 172 Algonquin Blvd. East, Timmins, ON, Canada, P4N 1A9 Telephone: (705) ~ Fax: (705) ~

7 Item #22 Reference: Drawings A1.2 Partial Floor Plans, Key Plan, Notes, General Notes and Legend Drawing #1/A1.2 Partial Floor Plan at Library #178 Clarification Disregard notes N14 and N42 within Library #178 Item #23 Reference: Drawings A1.2 Partial Floor Plans, Key Plan, Notes, General Notes and Legend Drawing #1/A1.2 Partial Floor Plan at Library #178 Clarification Contractor to note that all freestanding bookshelves will be cleared of books prior to construction by Owners forces. Existing bookshelves to be removed, salvaged and stored for reinstallation. Location for storage on site to be coordinated with Owner. Item #24 Reference: Drawings A1.2 Partial Floor Plans, Key Plan, Notes, General Notes and Legend Drawing #5/A1.2 Partial Floor Plan at Classrooms Additional Information Contractor to repair existing door #112 to match existing. Provide wood filler and new paint finish at door and frame. Colour by Owner. Item #25 Reference: Drawings A1.2 Partial Floor Plans, Key Plan, Notes, General Notes and Legend General Notes Additional Information Contractor to remove existing wall-mounted raceway within areas of renovation aside from that next to existing doorway locations unless noted otherwise. Vancouver Toronto Ottawa Timmins Thunder Bay Cornwall Sudbury PBK Architects Inc. 172 Algonquin Blvd. East, Timmins, ON, Canada, P4N 1A9 Telephone: (705) ~ Fax: (705) ~

8 Item #26 Reference: Drawings A1.7 Partial Roof Plan, Notes and Legend Additional Information Contractor to allow for re-roofing of additional roof area noted on drawing ADD1.3. Allow for new 24ga. prefinished metal cap flashing at perimeter c/w scupper. Item #27 Reference: Drawings A1.7 Partial Roof Plan, Notes and Legend Drawing #1/A1.7 Partial Roof Plan Additional Information Contractor to remove roof vent box penetration at north portion of roof area #1. Associated ductwork into classroom #108, curbs and flashing to be removed. Provide metal pan roof decking welded to match existing c/w L3x3x1/4 framing around deck opening and extended to existing joists for support. Item #28 Reference: Drawings A1.7 Partial Roof Plan, Notes and Legend Drawing #/A1.7 Partial Roof Plan Additional Information Existing exhaust vents located on the vertical plane (east wall) at roof area #4 to be inspected for function. Contractor to include for the extension of service lines as required to suit reinstallation within new roof construction assembly. Item #29 Reference: Structural Drawings Additional Information Refer to attached Struc01 Addendum dated March 17, 2014 from WSP. (1 page) Vancouver Toronto Ottawa Timmins Thunder Bay Cornwall Sudbury PBK Architects Inc. 172 Algonquin Blvd. East, Timmins, ON, Canada, P4N 1A9 Telephone: (705) ~ Fax: (705) ~

9 Item #30 Reference: Mechanical Drawings Additional Information Refer to attached mechanical Addendum No. 1 dated March 10, 2014 from WSP. (5 pages) Item #31 Reference: Electrical Drawings Additional Information Refer to attached electrical Addendum No. 01 dated March 17, 2014 from WSP. (4 pages) End of Addendum Brett Weatherby, B.Sc. Arch., Dipl. Arch. Tech. PBK Architects Inc. Vancouver Toronto Ottawa Timmins Thunder Bay Cornwall Sudbury PBK Architects Inc. 172 Algonquin Blvd. East, Timmins, ON, Canada, P4N 1A9 Telephone: (705) ~ Fax: (705) ~

10 École catholique St-Michel Building Envelope Upgrade Addendum #1 - Document New Liskeard, Ontario APPENDIX C: ALTERNATIVE PRICES Project # Page 1 TENDER SUBMITTED BY: ALTERNATIVE PRICES The following are our prices for Alternative Work listed hereunder. Such Alternative Work and amounts are NOT included in our Base Bid. (If not used, bar and initial the space below.) Prices listed shall exclude the HST. Description of Alternate Work Effect on Base Bid ($) Addition Cost to substitute Sarnafil PVC membrane with Lexcan fully adhered PVC membrane. Deletion Contractor s Signature

11 École catholique St-Michel Building Envelope Upgrade Document New Liskeard, Ontario APPENDIX D: ADD-IN / TAKE-OUT PRICES Project # Page 1 TENDER SUBMITTED BY: ADD-IN PRICES The following are our Add-In prices for the work listed hereunder. Such Add-In Work and monetary amounts are NOT included in our Stipulated Price. (If not used, bar and initial the space below.) Prices listed shall exclude the H.S.T. Description of Add-In Work Effect on Stipulated Price ($) Addition Mechanical and electrical cost for Grinder Pumps in lieu of the specified sewage pumps. Refer to Mechanical Drawing M1.2 for Grinder pump specifications TAKE-OUT PRICES The following are our take out prices for Work listed hereunder. Such Work is included in our Stipulated Price. Should the Owner elect to delete this work, the base bid shall be reduced by the amounts shown below. (If not used, bar and initial the space below.) Prices listed shall exclude the H.S.T. Description of Take Out Work Effect on Stipulate Price ($) Deletion Contractor s Signature

12 DESIGNATED SUBSTANCE SURVEY ÉCOLE CATHOLIQUE ST MICHEL ROUTE 11 B NORD, NEW LISKEARD, ON APRIL 2009 Préparé par: 70C Mountjoy Street N Suite 125 Timmins, ON P4N 4V7

13 March 30 th, 2012 Designated Substance Survey CSCDGR Ecole Catholique St. Michel 1.0 INTRODUCTION Conseil Scolaire Catholique de Grandes Rivieres (CSCDGR) is a French Catholic School Board serving North Eastern Ontario. As part of due diligence as well as per regulatory requirements, BZ Environmental Consulting was retained by the CSCDGR, to complete a Designated Substance Inventory ( DSI ) for each of their Schools and buildings. The objective of the DSI was to identify and quantify designated substances as defined by the Ontario Occupational Health and Safety Act (OHSA) and the Ontario Ministry of Labour (MOL) including: asbestos-containing materials (ACM), lead, arsenic, benzene, mercury, vinyl chloride, acrylonitrile, silica, isocyanates coke oven emissions; ethylene oxides and other hazardous and designated substances including ozone-depleting substances, polychlorinated biphenyl (PCB)-containing equipment, urea formaldehyde foam insulation, and man-made mineral fibres. 1 BZ Environmental Consulting 70C Mountjoy Street N., Suite 125, Timmins, ON P4N 4V7

14 March 30 th, 2012 Designated Substance Survey CSCDGR Ecole Catholique St. Michel 1.1 REGULATORY REQUIREMENTS This Designated Substance Report has been undertaken to fulfil the Conseil Scolaire Catholique de Grandes Rivieres (CSCDGR) requirements under Section 30 of the Ontario Occupational Health and Safety Act, (the OHSA ), Revised Statutes of Ontario 1990, (as amended). Conseil Scolaire Catholique de Grandes Rivieres (CSCDGR) must provide this report to all workers and contractors who may or may not come into contact with Designated Substances in the buildings. The Designated Substances defined under the OHSA and their corresponding regulations at the time of the survey are summarized in Table 1. Designated Substances as defined by the OHSA means a biological, chemical or physical agent or combination thereof prescribed as a designated substance to which the exposure of a worker is prohibited, regulated, restricted, limited or controlled. The OHSA has issued specific regulations under Section 30 of the Act for these substances. The Designated Substance Regulations identified under the Industrial Regulation of the OHSA, provide guidance on exposure and medical monitoring, permissible occupational exposure limits, etc. Ontario Regulation 278/05 ( O.Reg. 278/05 ) regulates the disturbance of asbestos on construction projects and is enforced by the Ontario Ministry of Labour ( MOL ). Ontario Regulation 111/04 ( O.Reg. 111/04 ) regulates the disturbance of silica on construction projects and is enforced by the Ontario Ministry of Labour ( MOL ). The appropriate reference document is entitled Guideline Silica on Construction Projects September Ontario Ministry of Labour. The MOL guideline for the control of lead exposures during the removal of lead on construction projects does not include criteria for categorizing lead-paint. The United States Department of Housing and Urban Development ( U.S. HUD ), and the Canadian Federal Hazardous Products Act ( HPA ), however, defines leadbased paint as any paint application containing at least 0.5% lead by weight (5,000 parts per million-ppm), if tested by chemical analysis. Paint samples found to contain concentrations of lead that exceeds 0.5% lead that exceeds 0.5% lead by weight are considered lead containing paint under the HPA. 2 BZ Environmental Consulting 70C Mountjoy Street N., Suite 125, Timmins, ON P4N 4V7

15 March 30 th, 2012 Designated Substance Survey CSCDGR Ecole Catholique St. Michel 1.2 DESIGNATED SUBSTANCES Substance Acrylonitrile Arsenic Asbestos Designated Substanceasbestos on construction projects and in buildings and repair operations * Benzene Coke Oven Emissions Ethylene Oxide Isocyanates Lead Mercury Silica Vinyl Chloride Regulations R.R , Reg.835, as amended by O.Reg, 101/04 R.R , Reg.836, as amended by O.Reg, 102/04 R.R , Reg.837, as amended by O.Reg, 279/04 R.R , Reg.278/05 R.R , Reg.839, as amended by O.Reg, 105/04 R.R , Reg.840, as amended by O.Reg, 106/04 R.R , Reg.841, as amended by O.Reg, 107/04 R.R , Reg.842, as amended by O.Reg, 108/04 R.R , Reg.843, as amended by O.Reg, 109/04 R.R , Reg.844, as amended by O.Reg, 110/04 R.R , Reg.845, as amended by O.Reg, 111/04 R.R , Reg.846, as amended by O.Reg, 112/04 Note: * The disturbance of asbestos on construction projects is specifically regulated by Ontario Regulation 278/05. It classifies all disturbance of asbestos as Type 1, Type 2 or Type 3, each of which is associated with defined work practices. All asbestos material waste is subject to special handling and disposal practices, and must be removed prior to partial or full demolition. Disposal of asbestos waste is subject to General Waste Management Regulation O. Reg. 347 as amended by 461/05. 3 BZ Environmental Consulting 70C Mountjoy Street N., Suite 125, Timmins, ON P4N 4V7

16 March 30 th, 2012 Designated Substance Survey CSCDGR Ecole Catholique St. Michel 2.0 DESIGNATED SUBSTANCE SURVEY Designated substances in the Province of Ontario are defined in accordance with the OHSA. The following section of this report provides an overview of the primary characteristics of such designated substances, their potential health effects and the potential presence of such substances at the School identified during the inspection. BZ Environmental representatives completed a School inspection and associated DSI on March 30 th, 2012 at Ecole Catholique St Michel, located at Route 11 B Nord, New Liskeard, ON. At the time of the DSI, BZ Environmental had access to all rooms within the school. 2.1 Acrylonitrile Acrylonitrile is a colourless to pale-yellow liquid at room temperature, with an unpleasant odour. It is used in the manufacturing of synthetic fibres, rubber, coatings and adhesives. Acrylonitrile is toxic by inhalation and by skin exposure. Low-level exposure to acrylonitrile may cause eye and skin irritation, headaches, nausea and vomiting. High level or prolonged exposure may result in damage to the heart, liver, kidneys, and central nervous system and acrylonitrile a known carcinogen. Site Conditions: Based on the examination of the School, it is not expected that acrylonitrile is present. However, there is a potential for release of acrylonitrile if plastic wire coatings and other materials combust during a fire. 2.2 Arsenic Arsenic is a silver/grey, brittle, crystalline solid at room temperature. Arsenic compounds are used as wood preservatives, insecticides, herbicides, and in metal alloys and are naturally present in certain minerals and soils. Arsenic is a poison and at high levels may cause death, cancer, nerve damage, stomach damage, intestinal damage, and skin damage. At lower levels it may cause nausea, diarrhoea, decreased production of red and white blood cells, and abnormal heart rhythm. Site Conditions: Based on the School inspection, no materials that may potentially contain arsenic were identified with the exception of any pressure treated wood exterior products, which typically contain chromated 4 BZ Environmental Consulting 70C Mountjoy Street N., Suite 125, Timmins, ON P4N 4V7

17 March 30 th, 2012 Designated Substance Survey CSCDGR Ecole Catholique St. Michel copper arsenate (CCA) from the pressure treatment process of wood. As pressure treated wood products may be present but not visible, ie: hidden due to building finishes, caution should be taken during any demolition activities which may expose pressure treated wood. 2.3 Asbestos Asbestos is the name used for a group of fibrous minerals that occur naturally in soil and rock. Asbestos fibres were formerly used for primarily its insulating and fireproofing properties in roofing shingles, ceiling tiles, floor tiles, asbestos cement products, gaskets, insulation, paper products, and other Building and insulating products. Asbestos mainly affects the respiratory system. Inhalation of asbestos may result in the build-up of scar-like tissue resulting in cancer of the lungs and the surrounding membrane. Site Conditions: An asbestos survey was conducted as part of the DSI. The results of the asbestos survey are presented in Appendix A. A summary of Asbestos-Containing Materials Sampled during the DSI is presented in Table 1. A summary of Confirmed Asbestos-Containing Materials is presented in Table Asbestos Containing Materials There are over 3,000 asbestos containing materials ( ACM ), which can be divided into two broad categories: friable and non-friable. Friable ACMs are defined as materials that can be crumbled, pulverized and reduced to powder when dry using hand pressure. Typical friable materials include acoustical or decorative spray applications, fireproofing and thermal insulation. Non-friable ACMs are hard or manufactured products such as floor tiles, fire blankets, pre-formed manufactured cementitious insulation and wallboards, pipes, and siding, wherein the asbestos fibres are bound. 2.5 Benzene Benzene is a colourless liquid at room temperature, with a sweet odour. Benzene and benzene-containing compounds are components of crude oil and refined petroleum products such as gasoline and are present in coal, natural gas and other materials. Benzene is used to manufacture other chemicals, which are 5 BZ Environmental Consulting 70C Mountjoy Street N., Suite 125, Timmins, ON P4N 4V7

18 March 30 th, 2012 Designated Substance Survey CSCDGR Ecole Catholique St. Michel used to make plastic, resin, nylon, rubber, lubricants, detergents, drugs, and other materials. Benzene is a human carcinogen. Exposures to benzene may cause dizziness, drowsiness, and unconsciousness. Long-term exposures may result in anaemia, leukemia, and damage to bone marrow. Site Conditions: Based on the School Inspection, BZ Environmental Consulting did not observe or identify and potential of benzene containing compounds. 2.6 Coke Oven Emissions Coke oven emissions are the airborne constituents of the by-products created by destructive distillation of coal and petroleum. Coke oven emissions are typically associated with the production of steel and coal processing/coke manufacture. Exposure to coke oven emissions is a potential cause of lung cancer. Dermal contact with coke oven emissions should be avoided. Site Conditions: Based on the School inspection, BZ Environmental Consulting did not observe or identify any potential for coke oven emissions to be present. 2.7 Ethylene Oxide Ethylene oxide is a colourless gas at room temperature and a liquid at 12 degrees Celsius. It is used in the manufacture of ethylene glycol, surfactants, fumigants, fungicides, and petroleum demulsifiers. Exposure routes include inhalation, ingestion, skin and/or eye contact. Exposure may cause irritation of the eyes, skin, nose and throat, headaches, nausea, and drowsiness. Exposure to high concentrations may cause frostbite, reproductive effects, convulsions, liver and kidney damage, and ethylene oxide is a known human carcinogen. Site Conditions: Based on the School inspection, no ethylene oxide containing substances were identified. 2.8 Lead Lead is a naturally occurring bluish-grey metal that is solid at room temperature. Lead is used in the manufacture of batteries, ammunition, solder, paint, and piping. 6 BZ Environmental Consulting 70C Mountjoy Street N., Suite 125, Timmins, ON P4N 4V7

19 March 30 th, 2012 Designated Substance Survey CSCDGR Ecole Catholique St. Michel The routes of exposure to lead are limited to inhalation and ingestion of lead, with the highest risk of lead exposure being the inhalation of lead containing dust. Lead can damage the nervous system, kidneys, and the immune system. Site Conditions: A lead-based paint-sampling program was conducted as part of the DSI and is presented in further detail within Section 4.0. There is also the possibility of lead piping used throughout the School; however, none was visually identified during DSI. 2.9 Mercury Mercury is a naturally occurring metal. At room temperature it is a shiny, silvercoloured odourless liquid. When heated it becomes a colourless, odourless gas. Mercury is used in electrical switches, thermostats, thermometers, dental fillings, certain batteries, and some manufacturing processes. The nervous system is very sensitive to all forms of mercury; however, vapour is especially harmful as it directly reaches the brain. Exposure to high levels of mercury may permanently damage the brain, kidneys and a developing fetus. Short-term exposure may cause lung damage, nausea, vomiting, skin rashes, and eye irritation. Site Conditions: At the time of the School inspection, there were no electrical switches, thermostats, thermometers, or any other electrical equipment that may contain mercury observed as being present in the School Silica Silica is a transparent to gray odourless powder or crystal at room temperature. It occurs widely in nature as sand, quartz, flint, and diatomite. Silica is used in the manufacture of glass, ceramics, abrasives, water treatment products, cosmetics, insecticides, paint and foods, as well as a drying agent or preservative. Crystalline silica materials also are used in the production of concrete, cement, acoustic ceiling tiles, and ceramic tiles which are used for construction purposes. The Ministry s designated substance regulation for silica, Regulation 845, specifies occupational exposure limits (OELs) for silica and requires assessment and a control program to ensure compliance with these OELs. The OEL for respirable crystalline silica is 0.05 milligrams per cubic metre (mg/m3) of air by volume as an 8-hour daily or 40-hour weekly time-weighted average for 7 BZ Environmental Consulting 70C Mountjoy Street N., Suite 125, Timmins, ON P4N 4V7

20 March 30 th, 2012 Designated Substance Survey CSCDGR Ecole Catholique St. Michel cristobalite and tridymite. In the case of quartz and Tripoli, the OEL is 0.10 milligrams per cubic meter of air by volume. Site Conditions: Based on the School inspection, crystalline silica is likely present in the building concrete (e.g., concrete slab floor and concrete block walls). As such, there is a potential for silica dust to be generated by the grinding, cutting, renovating, or demolition of School s materials Vinyl Chloride Vinyl chloride is a colourless, flammable gas at room temperature with a mild, sweet odour; Vinyl chloride is a degradation product of product of organic industrial/commercial solvents such as tetrachloroethylene (PCE) and trichloroethylene (TCE), which are used as degreasing and dry cleaning agents. One use of vinyl chloride is in the manufacture of polyvinyl chloride (PVC), which is used in many plastic products including plastic pipe, electrical cable insulation, plumbing and conduit fixtures, clothing, upholstery, roofing and flooring materials. Exposure to vinyl chloride occurs mainly in workplaces where it is used in plastic product manufacturing or chlorinated solvents are used. Breathing high levels of vinyl chloride for short periods of time can cause dizziness, sleepiness, unconsciousness, and, damage, immune reactions, nerve damage, and cancer. Site Conditions: Based on the examination of the School, it is not expected that vinyl chloride is present. However, there is the potential for release of vinyl chloride if building piping and wire cable coatings combust during a fire. 8 BZ Environmental Consulting 70C Mountjoy Street N., Suite 125, Timmins, ON P4N 4V7

21 March 30 th, 2012 Designated Substance Survey CSCDGR Ecole Catholique St. Michel 3.0 ASBESTOS SURVEY 3.1 General The asbestos containing material (ACM) survey was conducted on April 22, A second visit to the school was done on June 23 rd 2011, and a third visit to the school was completed on March 30 th, The asbestos survey was completed with consideration to Ontario Regulation (O.Reg.) 278/05 entitled Designated Substance Asbestos on Construction Projects and in Buildings and Repair Operations. O.Reg. 278/05 revoked and replaced O.Reg. 838/90 on November 1, Sampling activities were performed in accordance with bulk asbestos sampling procedures outlined in O.Reg 278/05 and in the document entitled Designated Substances in the Workplace: A Guide to the Asbestos Regulation for Construction Projects, Buildings and Repair Operations, MOL, April In areas where finished surfaces required partial removal to inspect hidden materials (e.g., surface coverings on pipe insulation and multiple layers of flooring material), openings were made by BZ Environmental to allow for inspection of the underlying materials. 3.2 Sampling Representatives of BZ Environmental Consulting performed a Site inspection and associated DSI on April 22, 2009, whereby all accessible areas of the school were examined. A second visit to the school was done on June 23 rd 2011, and a third visit to the school was completed on March 30 th, The inspection consisted of a visual survey of accessible interior and exterior areas and included the collection of select representative building material samples. Based on the age and use of the building, the assessment focused on identifying the most common applications of building materials likely to contain Designated Substances. Representative bulk samples of building materials suspected of containing asbestos were collected for analysis. Eleven (11) suspected asbestos-containing materials were submitted in triplicate to EMSL Analytical, Inc, in Westmount, NJ. EMSL Analytical is accredited for bulk asbestos fibre analysis. Samples were analyzed using polarized light microscopy ( PLM ) technique (following method EPA/600/R-93/116). This standard is specified by Ontario Regulation 278/05 as the method for establishing whether the material is asbestos-containing and defining the content 9 BZ Environmental Consulting 70C Mountjoy Street N., Suite 125, Timmins, ON P4N 4V7

22 March 30 th, 2012 Designated Substance Survey CSCDGR Ecole Catholique St. Michel and type of asbestos. Triplicate samples taken in order to satisfy the requirements of Ontario Regulation 278/ BZ Environmental Consulting 70C Mountjoy Street N., Suite 125, Timmins, ON P4N 4V7

23 March 30 th, 2012 Designated Substance Survey CSCDGR Ecole Catholique St. Michel All samples identified to have an asbestos content of 0.5% or higher are summarized in Table 2. The survey included minimal destructive testing of drywall surfaces. However, it is possible that materials may exist which could not be reasonably identified within the scope of the assessment or which were not apparent or accessible during the site visit. An area above a suspended tile ceiling, behind a closed door, or behind an access hatch is considered accessible. An area enclosed by gypsum board, plaster, or panelling, roofing materials, boiler refractory, etc., where minor demolition is required to gain entry, is considered non-accessible and was not included as part of this investigation TABLE 1 SAMPLES SUBMITTED WITH ASBESTOS CONTENT 2009 Sample ID Material Description Location Condition 1 a-b-c 9 X 9 Floor Tile (green) hallway Good 2 a-b-c Elbow Pipe Cement hallway Good 3 a-b-c Elbow Pipe Cement Hallway - black Good 4 a-b-c Ceiling Tile Classroom Good SAMPLES SUBMITTED WITH ASBESTOS CONTENT 2011 Sample ID Material Description Location Condition 1 a-b-c Floor Tile green Music Room (135) Good 2 a-b-c Floor Tile beige Room 160 Good 3 a-b-c Floor Tile beige Room 122 Good 4 a-b-c Floor Tile white Room 108 Good 5 a-b-c Floor Tile white Room 119 Good 6 a-b-c Floor Tile white Room 110 Good 7 a-b-c Floor Tile - green Hallway Good 11 BZ Environmental Consulting 70C Mountjoy Street N., Suite 125, Timmins, ON P4N 4V7

24 March 30 th, 2012 Designated Substance Survey CSCDGR Ecole Catholique St. Michel Definitions of Condition Good Condition: - Non-Friable - Asbestos is well maintained and is very unlikely to become friable - Friable asbestos is fully encapsulated and is not airborne Fair Condition: - Non-Friable asbestos is maintained but may need future attention if left alone. - Friable asbestos is encapsulated but may need further attention if left alone. Poor Condition: - Non-Friable asbestos is cracking and breaking and may become friable. - Friable asbestos may be airborne. - Enclosure and removal is highly recommended TABLE 2 CONFIRMED ASBESTOS CONTAINING MATERIAL RECORD 2009 Sample Material Description Friable or Asbestos % & Type ID Non-Friable 1a-b-c 9 X 9 Floor Tile (green) Non-Friable 2% Chrysotile 2 a-b-c Elbow Pipe Cement Hallway Non-Friable None Detected 3 a-b-c Elbow Pipe Cement Black Non-Friable None Detected 4 a-b-c Ceiling Tile Non-Friable None Detected CONFIRMED ASBESTOS CONTAINING MATERIAL RECORD 2011 Sample Material Description Friable or Asbestos % & Type ID Non-Friable 1 a-b-c Floor Tile green Non-Friable 4% Chrysotile 2 a-b-c Floor Tile beige Non-Friable 2% Chrysotile 3 a-b-c Floor Tile beige Non-Friable None Detected 4 a-b-c Floor Tile white Non-Friable 8% Chrysotile 5 a-b-c Floor Tile white Non-Friable 5% Chrysotile 6 a-b-c Floor Tile white Non-Friable 9% Chrysotile 7 a-b-c Floor Tile - green Non-Friable 4% Chrysotile 12 BZ Environmental Consulting 70C Mountjoy Street N., Suite 125, Timmins, ON P4N 4V7

25 March 30 th, 2012 Designated Substance Survey CSCDGR Ecole Catholique St. Michel 3.3 Confirmed ACM Based on the analytical report, seven of the building materials collected contained asbestos fibres in exceedance of 0.5 percent. 13 BZ Environmental Consulting 70C Mountjoy Street N., Suite 125, Timmins, ON P4N 4V7

26 March 30 th, 2012 Designated Substance Survey CSCDGR Ecole Catholique St. Michel 4.0 LEAD PAINT SURVEY 4.1 General A lead paint-sampling inspection was conducted during the April 22, 2009, School inspection. Sampling activities were performed in accordance with bulk lead sampling procedures outlined in the document entitled Designated Substances in the Workplace: A Guide to the Lead Regulation for Construction Projects, Buildings and Repair Operations, MOL, Ontario Regulation 843 (1990). The above-mentioned sampling protocol is recommended by the MOL for lead paint sampling. As part of this lead paint survey, there was one paint chip sample collected. Sample ID Material Description Location Condition 5 a-b-c Paint Hallway Good 4.2 Analytical Results One Paint chip sample was collected during the inspection. The results of this sample indicated lead levels ranging from 0.020% % by weight and should be considered lead free. No guidelines exist in the Province of Ontario defining when a coating is considered to be lead-based. However, Ontario Regulation 109/04 stipulates that workers are not to be exposed to airborne lead levels in exceedance of the TWAEV or MAC values outlined in the regulation. BZ Environmental Consulting recommends that the measures outlined in the Ministry of Labour s Guideline for Lead on Construction Project (September 2004) be put into place to control potential lead dust hazard during any work, which involves the disturbance of a painted surface. This is particularly important for painted surfaces that exhibit elevated concentrations of lead identified during the DSI. Sample Material Description Lead Concentration Condition ID 5 a-b-c Paint None Detected Good 14 BZ Environmental Consulting 70C Mountjoy Street N., Suite 125, Timmins, ON P4N 4V7

27 March 30 th, 2012 Designated Substance Survey CSCDGR Ecole Catholique St. Michel 5.0 CONCLUSIONS A designated substance survey was completed at Ecole Catholique St Michel located at Route 11 B North in New Liskeard, ON, on April 22, A second visit to the school was done on June 23 rd 2011, and a third visit to the school was completed on March 30 th, A total of eleven (11) samples were identified as suspected Asbestos Containing Material and one (1) sample was identified as suspected lead containing material. Laboratory analysis determined that seven (7) of these samples were Asbestos containing and the lead suspected material did not exceeds the limits. Silica was suspected to be present in sand, concrete, brick and mortar. There were no immediate dangers found with any of these substances. There were no other issues identified. Representative samples Please assume that all similar materials found within buildings will have similar asbestos and/or lead content when materials are found from the same construction year in the same building. 6.0 LIMITATIONS The information, conclusions and recommendations given herein are specifically for this project and this client only, and the scope of work described herein. It may not be sufficient for other uses. The conclusions and recommendations regarding environmental conditions, which are presented in this report are based on a scope of work authorized by the Client, however, it should be noted that virtually no scope of work, no matter how exhaustive, can identify all contaminants or all conditions above and below ground. For example, conditions between test holes or sample locations may differ from those encountered in the investigation and conditions may change with time. This report therefore cannot warranty that all conditions on or off the site are represented by those identified at specific locations. The services performed as described in this report were based on visual observations of the site, structures and outbuildings. There were no destructive investigations performed at this site. Note also that standards, guidelines and practices related to environmental investigations may change with time. Those that were applied at the time of this investigation may be obsolete or unacceptable at a later date. 15 BZ Environmental Consulting 70C Mountjoy Street N., Suite 125, Timmins, ON P4N 4V7

28 March 30 th, 2012 Designated Substance Survey CSCDGR Ecole Catholique St. Michel The comments given in this report on potential remediation problems and possible methods are intended only for the guidance of the designer. The scope of work may not be sufficient to determine all of the factors that may affect construction or clean-up methods and costs. Any results from an analytical laboratory reported herein have been carried out by others, in this case, EMSL Analytical and BZ Environmental Consulting does not warranty their accuracy. All laboratories used by BZ Environmental Consulting are accredited by the appropriate authorities for the specific registered tests. 7.0 CLOSURE We trust this information is sufficient for your present purposes. Should you have any questions, please do not hesitate to contact the undersigned directly. Yours Truly, BZ ENVIRONMENTAL Mark J. Bednarz, B.E.S., P.Geo., Sr. Environmental Geoscientist Stephane Mousseau Environmental Technician 16 BZ Environmental Consulting 70C Mountjoy Street N., Suite 125, Timmins, ON P4N 4V7

29

30

31 EMSL Analytical, Inc. 107 Haddon Ave., Westmont, NJ Phone: (856) Fax: (856) Attn: Mark Bednarz BZ Environmental Consulting 70 C Mount Joy Street North Suite 125 Timmins, ON P4N 4V7 Fax: (705) Phone: (705) Project: Customer ID: Customer PO: Received: EMSL Order: EMSL Proj: Analysis Date: BZEN78 04/28/09 9:20 AM /30/2009 Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via EPA600/R-93/116 Method Client Sample ID: Sample Description: Test 1A TILE GREEN HALLWAY FLOOR TILE Lab Sample ID: Analyzed Non Asbestos Date Color Fibrous Non-Fibrous Asbestos Comment PLM 4/30/2009 Olive 0% 98% 2% Chrysotile Client Sample ID: Sample Description: Test 1A MASTIC GREEN HALLWAY FLOOR TILE Lab Sample ID: A Analyzed Non Asbestos Date Color Fibrous Non-Fibrous Asbestos Comment PLM 4/30/2009 Black 0% 100% None Detected Client Sample ID: Sample Description: Test 1B TILE GREEN HALLWAY FLOOR TILE Lab Sample ID: Analyzed Non Asbestos Date Color Fibrous Non-Fibrous Asbestos Comment PLM 4/30/2009 Olive 0% 98% 2% Chrysotile Client Sample ID: Sample Description: Test 1B MASTIC GREEN HALLWAY FLOOR TILE Lab Sample ID: A Analyzed Non Asbestos Date Color Fibrous Non-Fibrous Asbestos Comment PLM 4/30/2009 Black 0% 100% <1% Chrysotile Client Sample ID: Sample Description: Test 1C TILE GREEN HALLWAY FLOOR TILE Lab Sample ID: Analyzed Non Asbestos Date Color Fibrous Non-Fibrous Asbestos Comment PLM 4/30/2009 Olive 0% 98% 2% Chrysotile Client Sample ID: Sample Description: Test 1C MASTIC GREEN HALLWAY FLOOR TILE Lab Sample ID: A Analyzed Non Asbestos Date Color Fibrous Non-Fibrous Asbestos Comment PLM 4/30/2009 Black 0% 100% None Detected OntarioEPA Printed: 4/30/ :42:41 PM Page 1

32 EMSL Analytical, Inc. 107 Haddon Ave., Westmont, NJ Phone: (856) Fax: (856) Attn:Mark Bednarz BZ Environmental Consulting EMSL Proj: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via EPA600/R-93/116 Method Client Sample ID: Sample Description: Test 2A PIPE WRAP "INSULATION" HALLWAY Lab Sample ID: Analyzed Non Asbestos Date Color Fibrous Non-Fibrous Asbestos Comment PLM 4/30/2009 Brown 90% 10% None Detected Client Sample ID: Sample Description: Test 2B PIPE WRAP "INSULATION" HALLWAY Lab Sample ID: Analyzed Non Asbestos Date Color Fibrous Non-Fibrous Asbestos Comment PLM 4/30/2009 Brown 90% 10% None Detected Client Sample ID: Sample Description: Test 2C PIPE WRAP "INSULATION" HALLWAY Lab Sample ID: Analyzed Non Asbestos Date Color Fibrous Non-Fibrous Asbestos Comment PLM 4/30/2009 Brown 90% 10% None Detected Client Sample ID: Sample Description: Test 3A PIPE WRAP - HALLWAY. BLACK. Lab Sample ID: Analyzed Non Asbestos Date Color Fibrous Non-Fibrous Asbestos Comment PLM 4/30/2009 Black 60% 40% None Detected Client Sample ID: Sample Description: Test 3B PIPE WRAP - HALLWAY. BLACK. Lab Sample ID: Analyzed Non Asbestos Date Color Fibrous Non-Fibrous Asbestos Comment PLM 4/30/2009 Black 60% 40% None Detected Client Sample ID: Sample Description: Test 3C PIPE WRAP - HALLWAY. BLACK. Lab Sample ID: Analyzed Non Asbestos Date Color Fibrous Non-Fibrous Asbestos Comment PLM 4/30/2009 Black 60% 40% None Detected Client Sample ID: Sample Description: Test 4A CEILING TILE Lab Sample ID: Analyzed Non Asbestos Date Color Fibrous Non-Fibrous Asbestos Comment PLM 4/30/2009 Brown/White 85% 15% None Detected Client Sample ID: Sample Description: Test 4B CEILING TILE Lab Sample ID: Analyzed Non Asbestos Date Color Fibrous Non-Fibrous Asbestos Comment PLM 4/30/2009 Brown/White 75% 25% None Detected OntarioEPA Printed: 4/30/ :42:42 PM Page 2

33 EMSL Analytical, Inc. 107 Haddon Ave., Westmont, NJ Phone: (856) Fax: (856) Attn:Mark Bednarz BZ Environmental Consulting EMSL Proj: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via EPA600/R-93/116 Method Client Sample ID: Sample Description: Test 4C CEILING TILE Lab Sample ID: Analyzed Non Asbestos Date Color Fibrous Non-Fibrous Asbestos Comment PLM 4/30/2009 Brown/White 85% 15% None Detected PLM: Analyst(s) Erica Valent Nancy Stalter Stephen Siegel, CIH, Laboratory Manager or other approved signatory None Detected = <0.5%. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP of any agency of the U.S. Government. AIHA IHLAP , NVLAP Lab Code , NYS ELAP OntarioEPA Printed: 4/30/ :42:43 PM THIS IS THE LAST PAGE OF THE REPORT. Page 3

34

35

36 EMSL Analytical, Inc. 3 Cooper St., Westmont, NJ Phone: (856) Fax: (856) westmontleadlab@emsl.com Attn: Mark Bednarz BZ Environmental Consulting 70 C Mount Joy Street North Suite 125 Timmins, ON P4N 4V7 Fax: (705) Phone: (705) Project: Customer ID: BZEN78 Customer PO: CC Received: 04/28/09 12:00 PM EMSL Order: EMSL Proj: Lead in Paint Chips by Flame AAS (SW B*/7420) Client Sample Description Lab ID Collected Analyzed 5A /30/2009 Hallway 5B /30/2009 Hallway 5C /30/2009 Hallway Lead Concentration <0.020 % wt <0.032 % wt <0.028 % wt Shannon Kauffman, Lead Lab Supervisor or other approved signatory Reporting limit is 0.01 % wt. The QC data associated with these sample results included in this report meet the method quality control requirements, unless specifically indicated otherwise. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. * slight modifications to methods applied Samples received in good condition unless otherwise noted. Quality Control Data associated with this sample set is within acceptable limits, unless otherwise noted ACCREDITATIONS: NJ-NELAP: 04653, AIHA Environmental Lead Laboratory Approval Program: ChmSnglePrm/nQC Printed: 5/1/ :24:18 A Page 1 of 1

37

38

39 Asbestos Lead Environmental Materials & Indoor Air Analysis EMSL Canada Inc. 10 Falconer Drive, Unit #3 Mississauga, ON L5N 3L8 Phone: Fax: (289) Web: Attn: Mark Bednarz BZ Environmental Consulting 70 C Mount Joy Street North Suite 125 Timmins, ON P4N 4V7 Fax: (705) Phone: (705) Proj: /ST. MICHAEL EMSL Order: Customer ID: 55BZEN78 Collected: Received: 7/13/2011 Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via EPA600/R-93/116 Method Client Sample ID: Sample Description: 1A VERT (REFECTOIRE) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 White/Green 0% 96% 4% Chrysotile Client Sample ID: Sample Description: 1B VERT (REFECTOIRE) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 White/Green 0% 96% 4% Chrysotile Client Sample ID: Sample Description: 1C VERT (REFECTOIRE) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 White/Green 0% 95% 5% Chrysotile Client Sample ID: Sample Description: 2A 12x12 BEIGE (160) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 Tan 0% 98% 2% Chrysotile Client Sample ID: Sample Description: 2B 12x12 BEIGE (160) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 Tan 0% 99% 1% Chrysotile Client Sample ID: Sample Description: 2C 12x12 BEIGE (160) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 Tan 0% 97% 3% Chrysotile Client Sample ID: Sample Description: 3A 12x12 BEIGE (122) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 Tan/White 0% 100% None Detected Test Report:EPAMultiTests Printed: 7/27/ :22PM Page 1 of 3

40 EMSL Canada Inc. 10 Falconer Drive, Unit #3 Mississauga, ON L5N 3L8 Phone: Fax: (289) Web: Attn: Mark Bednarz BZ Environmental Consulting 70 C Mount Joy Street North Suite 125 Timmins, ON P4N 4V7 Proj: /ST. MICHAEL Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via EPA600/R-93/116 Method Client Sample ID: Sample Description: 3B 12x12 BEIGE (122) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 Tan/White 0% 100% None Detected Client Sample ID: Sample Description: 3C 12x12 BEIGE (122) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 Tan/White 0% 100% None Detected Client Sample ID: Sample Description: 4A BLANC (108) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 Tan 0% 92% 8% Chrysotile Client Sample ID: Sample Description: 4B BLANC (108) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 Tan/Various 0% 92% 8% Chrysotile Client Sample ID: Sample Description: 4C BLANC (108) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 Tan/Various 0% 92% 8% Chrysotile Client Sample ID: Sample Description: 5A BLANC (119) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 Gray/Black 0% 95% 5% Chrysotile Client Sample ID: Sample Description: 5B BLANC (119) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 Gray/Black 0% 95% 5% Chrysotile Client Sample ID: Sample Description: 5C BLANC (119) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 Gray/Black 0% 95% 5% Chrysotile Test Report:EPAMultiTests Printed: 7/27/ :22PM Page 2 of 3

41 EMSL Canada Inc. 10 Falconer Drive, Unit #3 Mississauga, ON L5N 3L8 Phone: Fax: (289) Web: Attn: Mark Bednarz BZ Environmental Consulting 70 C Mount Joy Street North Suite 125 Timmins, ON P4N 4V7 Proj: /ST. MICHAEL Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via EPA600/R-93/116 Method Client Sample ID: Sample Description: 6A 9x9 BLANC (110) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 Brown/Tan 0% 90% 10% Chrysotile Client Sample ID: Sample Description: 6B 9x9 BLANC (110) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 Brown/Tan 0% 92% 8% Chrysotile Client Sample ID: Sample Description: 6C 9x9 BLANC (110) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 Brown/Tan 0% 90% 10% Chrysotile Client Sample ID: Sample Description: 7A 12x12 VERT (COULOIR) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 White/Green 0% 97% 3% Chrysotile Client Sample ID: Sample Description: 7B 12x12 VERT (COULOIR) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 White/Green 0% 95% 5% Chrysotile Client Sample ID: Sample Description: 7C 12x12 VERT (COULOIR) Lab Sample ID: Analyzed Non-Asbestos TEST Date Color Fibrous Non-Fibrous Asbestos Comment PLM 7/27/2011 White/Green 0% 96% 4% Chrysotile Initial report from: 07/27/201118:22:11 Analyst(s) Kevin Pang PLM (21) Kevin Pang or other Approved Signatory Any questions please contact Kevin Pang. None Detected = <0.5%. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP of any agency of the U.S. Government. Samples analyzed by EMSL Canada Inc. Mississauga, ON NVLAP Lab Code Test Report:EPAMultiTests Printed: 7/27/ :22PM Page 3 of 3

42 DESIGNATED SUBSTANCE SURVEY ECOLE CATHOLIQUE ST. MICHEL 77 River St. Englehart, ON Location/Area: Room 160 Photos # : Room Characteristics Non-Suspect Materials Other Non-Suspect Materials Floor Wall Ceiling 9 x 9 floor tiles Drywall Drop Ceiling Photo # 1 Photo # 2 Photo # 3 Photo # 4 Suspect Material Colour Sample No. Analytical Results % Type/PPM 9 x 9 Floor Tile Beige 2A2B2C 2 % Chrysotile 3 Photo # Friability Non- Friable Condition Rating Good Page 1

43 DESIGNATED SUBSTANCE SURVEY ECOLE CATHOLIQUE ST. MICHEL 77 River St. Englehart, ON Location/Area: Room 122 Photos # : Room Characteristics Non-Suspect Materials Other Non-Suspect Materials Floor Wall Ceiling 9 x 9 floor tiles Drywall Drop Ceiling Photo # 1 Photo # 2 % Type/PPM Photo # Friability Condition Rating 9 x 9 Floor Tile Beige 3A3B3C Asbestos not detected 2 Non- Friable Good Page 2

44 DESIGNATED SUBSTANCE SURVEY ECOLE CATHOLIQUE ST. MICHEL 77 River St. Englehart, ON Location/Area: Hallway Photos # : Room Characteristics Non-Suspect Materials Other Non-Suspect Materials Floor Wall Ceiling 9 x 9 Floor Tiles Drywall/cement blocks Drywall Photo # 1 Photo # 2 Photo # 3 Photo # 4 Photo # 5 Photo # 6 Analytical Results Photo Condition Suspect Material Colour Sample No. Friability % Type/PPM # Rating 9 x 9 Floor Tiles Green 7A7B7C 4% Chrysotile Non-friable Good 9 x 9 Floor Tiles Green 1A1B1C 2% Chrysotile Non-friable Good Asbestos not Elbow Pipe Cement White 2A2B2C 5 Friable Good detected Elbow Pipe Cement Black 3A3B3C Asbestos not detected 4 Friable Good 9 x 9 Floor Tile White 5% Chrysotile Non-friable Good Paint Chip 5A5B5C Lead not detected 6 Friable Good Page 3

45 DESIGNATED SUBSTANCE SURVEY ECOLE CATHOLIQUE ST. MICHEL 77 River St. Englehart, ON Location/Area: Refectoire - Room 135 Photos # : Room Characteristics Non-Suspect Materials Other Non-Suspect Materials Floor 9 x 9 floor tile Possible ACM Mercury Thermostate Wall Ceiling Drywall/ Drywall Photo # 1 Photo # 2 Photo # 3 Analytical Results Photo Condition Suspect Material Colour Sample No. Friability % Type/PPM # Rating 9 x 9 floor tile Green 1A1B1C 4% Chrysotile 3 Non-friable Good Page 4

46 DESIGNATED SUBSTANCE SURVEY ECOLE CATHOLIQUE ST. MICHEL 77 River St. Englehart, ON Location/Area: Room 119 Photos # : Room Characteristics Non-Suspect Materials Other Non-Suspect Materials Floor Wall Ceiling 9 x 9 Floor Tile Cement blocks with drywall over it Drop ceiling Photo # 1 Analytical Results Photo Condition Suspect Material Colour Sample No. Friability % Type/PPM # Rating 9 x 9 Floor Tile White 5A5B5C 5% Chrysotile 2 Non-friable Good Also found in Room 132 Page 5

47 DESIGNATED SUBSTANCE SURVEY ECOLE CATHOLIQUE ST. MICHEL 77 River St. Englehart, ON Location/Area: Room 108 Photos # : Room Characteristics Non-Suspect Materials Other Non-Suspect Materials Floor Wall Ceiling 9 x 9 Floor Tile Cement blocks with drywall over it Drop ceiling Photo # 1 Photo # 2 Analytical Results Photo Condition Suspect Material Colour Sample No. Friability % Type/PPM # Rating 9 x 9 Floor Tile White 4A4B4C 8% Chrysotile 2 Non-friable Good Page 6

48 DESIGNATED SUBSTANCE SURVEY ECOLE CATHOLIQUE ST. MICHEL 77 River St. Englehart, ON Location/Area: Room 110 Photos # : Room Characteristics Non-Suspect Materials Other Non-Suspect Materials Floor Wall Ceiling 9 x 9 Floor Tile Cement blocks with drywall over it Drop ceiling Photo # 1 Photo # 2 Photo # 3 Analytical Results Photo Condition Suspect Material Colour Sample No. Friability % Type/PPM # Rating 9 x 9 Floor Tile White 6A6B6C 9% Chrysotile 2 Non-friable Good Ceiling Tile White 4A4B4C Asbestos not detected 3 Non-friable Good Page 7

49

50

51 École catholique St-Michel Building Envelope Upgrade Section New Liskeard, Ontario SPRAYED IN PLACE URETHANE INSULATION Project # Page 1 1 General 1.1 GENERAL REQUIREMENT.1 Conform to sections of Division 1 as applicable. 1.2 RELATED WORK.1 Section Wind-Load Bearing Steel Stud System.2 Section Rough Carpentry installation of fiberglass spacers, girts and blocking.3 Section Prefinished Fiber Cement Siding.4 Section Joint Sealers 1.3 REFERENCES.1 CAN/ULC S705.2 Spray Applied Rigid Polyurethane Cellular Plastic Thermal Insulation..2 Closed Cell Medium Density CAN/ULC S Closed Cell Medium Density CAN/ULC S Single component bead sealant CAN/ULC S Single component bead sealant CAN/ULC S Two component bead sealant CAN/ULC S Two component bead sealant CAN/ULC S National Energy Conservation Association (NECA)..9 Canadian Urethane Foam Contractors Association (CUFCA) Quality Assurance Program, June Quality Assurance Professionals (QAP) Quality Assurance Program. 1.4 SUBMITTALS.1 Submit six (6) copies of shop drawings to requirements of Section Submittals..2 Shop Drawings: Provide drawings of construction and expansion joint conditions and junctions between dissimilar materials..3 Product Data: Provide data on insulation material characteristics, performance criteria, limitations and compatibility..4 Submit test reports, verifying qualities of insulation meet or exceed requirements of this specification..5 Manufacturer s Installation Instructions: Indicate preparation, installation requirements and techniques, product storage and handling criteria, for insulation.

52 École catholique St-Michel Building Envelope Upgrade Section New Liskeard, Ontario SPRAYED IN PLACE URETHANE INSULATION Project # Page 2.6 Provide copy of Foam Contractor s Photo ID license card issued by CUFCA or QAP Quality Assurance Program. Installers must provide copies of their installer card that shows reference to their training provider and certification for the material being used..7 Copy of Applicator s Certification and documentation that the applicators have complete the CUFCA/NECA or QAP/EXOVA, Quality Assurance Program. 1.5 QUALITY ASSURANCE.1 Application of insulation/air seal system only by applicators certified by either CUFCA/NECA (Canadian Urethane Foam Contractors Association/National Energy Conservation Association) or Quality Assurance Professionals (QAP)/EXOVA Canada..2 Maintain one copy of installation manual on site..3 Installers of insulation/air seal system to perform daily on-site testing and maintain daily work reports in accordance with the Material Manufacturer s Quality Assurance Program and to the satisfaction of the Consultant. 1.6 PROTECTION.1 In enclosed areas of application, ventilate area to receive insulation by introducing fresh air and exhausting air continuously during and 24 hr. after application to maintain nontoxic, unpolluted, safe working conditions..2 Provide temporary enclosures to prevent spray and noxious vapours from contaminating air beyond interior application area..3 Protect workers as recommended by insulation manufacturer..4 Protect adjacent surfaces and equipment from damage by overspray, fall-out, and dusting of insulation materials..5 Legally dispose of waste foam daily and decontaminate empty drums in accordance with foam manufacturer s instructions..6 Clean spills immediately in accordance with manufacturer s written instructions and authorities having jurisdiction. 1.7 QUALIFICATIONS.1 Installer to be Qualified Applicator of the products from the manufacturer/distributor - Submit proof of status..2 Material manufacturer/distributor must have an on site quality assurance program. Submit duplicate copy of quality assurance program. 1.8 MOCK-UP.1 Provide mock-up of materials under provisions of Section Quality Control..2 Construct typical exterior wall panel, 3m long by 1m wide, incorporating window and door frames and sills, insulation, building corner condition and control and expansion joint conditions, illustrating materials interface and seals.

53 École catholique St-Michel Building Envelope Upgrade Section New Liskeard, Ontario SPRAYED IN PLACE URETHANE INSULATION Project # Page 3.3 Mock-up may remain as part of the Work if approved. 1.9 PRE-INSTALLATION CONFERENCE.1 Convene one week prior to commencing work of this section, under provisions of Section Project Coordination and Project Meetings. Meeting shall be attended by the Project Manager, Field Quality Assurance provider Inspector, Insulation Applicator and the Consultant ENVIRONMENTAL REQUIREMENTS.1 Maintain temperature and humidity recommended by the materials manufacturer before, during and after installation COORDINATION.1 Coordinate the work of this Section with all affected trades including:.1 Section Wind-Load Bearing Steel Stud System.2 Section Rough Carpentry.3 Section Prefinished Fiber Cement Siding.4 Section Joint Sealers 1.12 WARRANTY.1 Warrant work of this Section against defects or deficiencies for a period of two years from date Work is substantially performed in accordance with General Condition of the Contract..2 Promptly correct, at own expense, defects of deficiencies which become apparent within the warranty period TESTING.1 Employ the services of Field Quality Assurance provider certified inspector to perform onsite review and testing to confirm compliance with these specifications. Inspector shall inspect and report prior to application and inspect, test and report at 50% and 100% complete stages. 2 Products 2.1 MATERIALS.1 Foam Insulation: sprayed/rigid polyurethane foam to CAN/ULC S705.1, CAN/ULC S705.2 and CCMC 07272, flame spread rating of less than 500, aged RSI value of 1.05m² K/W per 25mm. thickness at a density of 32.2 to 32.8 kg/m³. Acceptable products include BASF WALLTITE Eco v.3, Premium Spray Products FOAMSULATE ECO or approved equal. Thickness to be applied as indicated on architectural drawings and partition schedule..2 Transition Membrane to be used at all control joints and between all joints dissimilar materials prior to the application of the insulation. Install in widths of 300mm with 150mm cover to each side, and as noted on details. Material: Blueskin SA self-adhesive membrane complete with Blueskin Primer as manufactured by Bakor.

54 École catholique St-Michel Building Envelope Upgrade Section New Liskeard, Ontario SPRAYED IN PLACE URETHANE INSULATION Project # Page COMPATIBILITY.1 Ensure that all materials used are compatible..2 Provide proof of compatibility upon request. 3 Erection 3.1 PRODUCT DELIVERY, STORAGE AND HANDLING.1 Deliver materials in original unopened containers..2 Label containers with brand name, installation instructions and identification of various items..3 Store materials except membrane between 15 C and 27 C. If exposed to lower temperature restore to acceptable level before using..4 Store materials except membrane in dry area and protect. 3.2 EXAMINATION.1 Verify that surfaces and conditions are ready to accept the work of this section. Application of work of this section shall be deemed acceptance of existing work and existing conditions. Report in writing defects in substrate which may adversely affect the performance of the foam insulation/air seal..2 Examine joints before sealing to ensure configuration, surfaces and widths are suitable for foam sealant. Report in writing the location of joints that are deemed unacceptable for the application of joint sealant. 3.3 PREPARATION.1 Ensure surfaces to receive foam insulation are free of frost, loose or foreign matter which might impair adhesion of materials..2 Prepare surface by brushing, scrubbing, scraping or grinding to remove loose mortar, loose paint, dust, oil, grease, oxidation, mill scale and other contaminants which will affect adhesion and integrity of the foam insulation/air seal system. Wipe down metal surfaces to remove release agents or other non-compatible coating, using clean sponges or rags soaked in a solvent compatible with the foam insulation. Ensure surfaces are dry before proceeding. 3.4 APPLICATION.1 Installation and surface preparation/priming shall be in accordance with membrane manufacturer s recommendations for this application..2 Apply air/vapour barrier transition membrane over clean and dry surfaces..3 Before commencing work, the Contractor will ensure that environmental and site conditions are suitable for installation of material in accordance with the insulation manufacturer s recommendation, and notify Consultant in writing of suitable surfaces and conditions.

55 École catholique St-Michel Building Envelope Upgrade Section New Liskeard, Ontario SPRAYED IN PLACE URETHANE INSULATION Project # Page 5.4 Commencement of insulation work shall imply acceptance of surfaces and conditions..5 Apply foam insulation/air seal only when surfaces and ambient temperatures are within limits prescribed by the material manufacturer..6 Apply foam insulation in strict accordance with manufacturer s written instruction, specifications or recommendations..7 Finish joints shall be free from air pockets and imbedded foreign materials. Cut back excess foam sealant after cutting flush with surrounding surfaces unless otherwise directed and/or detailed..8 Apply foam insulation to within the following tolerances: +6.4mm; -0mm of thickness indicated on drawings..9 Finished sprayed foam insulation shall be free of voids and imbedded foreign material..10 Do not allow foam insulation to cover or mark adjacent surfaces. Use masking materials if necessary..11 Remove over-spray and masking materials immediately after foam has cured to hard surface film..12 Clean and make good surfaces soiled or damaged by work of this section. Consult with section of work soiled before cleaning to ensure methods used will not damage their work..13 Damage to work of this section caused by others shall be made good by this section at the expense of those causing the damage. END OF SECTION

56 ROOM FINISH SCHEDULE - R1 Project: École Catholique St-Michel Building Envelope Upgrade Location: New Liskeard, Ontario Project No: WALL CEILING No. NAME FLOOR BASE MATERIAL FINISH MATERIAL FINISH HEIGHT REMARKS 101 Vestibule ETR New RB and ETR, See remarks New GB and ETR, See remarks Paint and ETR. See remarks ETR Contractor to provide new 16mm Type 'X' Gypsum board finish fully adhered to existing brick veneer at new metal screen location. Provide 'J' moulding around existing wall heater to remain and new meta screen framing. Provide new rubber base at the new gypsum board wall covering. Provide good finish. 102 Lobby ETR ETR ETR ETR. ETR. 103 Reception ETR ETR ETR., see remarks Paint LIT 2315mm 104 Principal ETR ETR ETR. Paint LIT 2315mm 105 Kitchenette ETR ETR ETR. Paint LIT 2315mm Existing ceiling tile to be removed from existing gypsum board fire rated ceiling assembly. Contractor to patch with new 16mm Type 'X' gypsum board c/w tape and fill and repair existing fire rated assembly to match existing. Provide remedial work at new hollow metal screen location; ensure good finish. Contractor to provide new paint finish throughout. Existing ceiling tile to be removed from existing gypsum board fire rated ceiling assembly. Contractor to patch with new 16mm Type 'X' gypsum board c/w tape and fill and repair existing fire rated assembly to match existing. Contractor to provide new paint finish throughout Existing ceiling tile to be removed from existing gypsum board fire rated ceiling assembly. Contractor to patch with new 16mm Type 'X' gypsum board c/w tape and fill and repair existing fire rated assembly to match existing. Contractor to provide new paint finish throughout Page 1

57 ROOM FINISH SCHEDULE - R1 Project: École Catholique St-Michel Building Envelope Upgrade Location: New Liskeard, Ontario Project No: WALL CEILING No. NAME FLOOR BASE MATERIAL FINISH MATERIAL FINISH HEIGHT REMARKS VCT/PT, New and See Ex. GB. 108 Classroom Remarks RB to remain Paint LIT 2680mm 109 Vestibule PT RB 110 Classroom 111 Classroom VCT/PT, See Remarks VCT/PT, See Remarks 118 Corridor ETR ETR ETR 119 Classroom 128 Classroom VCT/PT, See Remarks VCT/PT, See Remarks RB RB RB RB 129 Vestibule PT RB New and Ex. GB. to remain Paint ETR New and Ex. GB. to remain Paint ETR. New and Ex. GB. to remain Paint ETR. New and Ex. GB. to remain New and Ex. GB. to remain New GB and ETR, See remarks ETR. See remarks. ETR. See remarks. ETR. See remarks. Paint, See Remarks ETR ETR Paint Paint New GB and ETR New GB and ETR Paint new GB and ETR. See remarks. Paint new GB and ETR. See remarks. Paint and ETR. See remarks LIT 2440 For extent of VCT and Porcelain tile finish, refer to floor plan on drawing sheet 'A1.2' Modify existing LIT ceiling to suit new wall construction. For extent of Porcelain tile finish, refer to floor plan on drawing sheet 'A1.2 Modify existing LIT ceiling to suit new exterior wall construction. For extent of VCT and Porcelain tile finish, refer to floor plan on drawing sheet 'A1.2' Modify existing LIT ceiling to suit new exterior wall construction. For extent of VCT and Porcelain tile finish, refer to floor plan on drawing sheet 'A1.2' Provide remedial work at new screen 'SC02' location to match existing. Typical to both sides of wall. Modify existing LIT ceiling to suit new exterior wall construction. For extent of VCT and Porcelain tile finish, refer to floor plan on drawing sheet 'A1.2'. For GB bulkheads, refer to related wall sections. Modify existing LIT ceiling to suit new exterior wall construction. For extent of VCT and Porcelain tile finish, refer to floor plan on drawing sheet 'A1.2'. For GB bulkheads, refer to related wall sections. New gypsum board walls to receive paint finish. Existing brick veneer to remain. Provide new rubber base throughout. Page 2

58 ROOM FINISH SCHEDULE - R1 Project: École Catholique St-Michel Building Envelope Upgrade Location: New Liskeard, Ontario Project No: WALL CEILING No. NAME FLOOR BASE MATERIAL FINISH MATERIAL FINISH HEIGHT REMARKS 130 Corridor VCT VCT/PT, See 131 Classroom Remarks VCT/PT, See 132 Classroom Remarks VCT, New RB, See remarks RB RB 133 Corridor ETR ETR Paint, GB, LIT, Paint, ETR & See See LIT, See GB Remarks remarks remarks New and Ex. GB. to remain Paint LIT LIT New and Ex. GB. to remain Paint LIT LIT ETR, See remarks Paint, See Remarks ETR ETR. See remarks. See remarks Existing terrazo floor finish to remain. At new Gypsum board wall partitions, contractor to provide new rubber base as specified. Provide new paint finish at new wall partitions. For new LIT ceiling c/w bulkhead layouts, refer to Reflected Ceiling Plans on drawing sheet 'A1.6'. Provide new VCT floor finish. Extent of new VCT floor to be in line with west wall of Corridor #118. Provide good finish. For extent of VCT and Porcelain tile finish, refer to floor plan on drawing sheet 'A1.2' For extent of VCT and Porcelain tile finish, refer to floor plan on drawing sheet 'A1.2' Contractor to provide remedial work at new locker location upon removal of existing coat hooks and shelving and closet storage. Provide paint finish and rubber base at locker location to match existing. 134 Vestibule ETR ETR ETR ETR ETR ETR Page 3

59 ROOM FINISH SCHEDULE - R1 Project: École Catholique St-Michel Building Envelope Upgrade Location: New Liskeard, Ontario Project No: WALL CEILING No. NAME FLOOR BASE MATERIAL FINISH MATERIAL FINISH HEIGHT REMARKS 152 Storage Room 160 Science Classroom VCT RB 174 Storage Room VCT, see remarks RB ETR Paint ETR & GB Paint VCT, see remarks RB ETR Paint ETR, See remarks ETR, See remarks ETR, See remarks ETR ETR ETR Review and replace any damaged ceiling tiles to match existing. Remove existing paint finish down to bare concrete block where applicable using Bristle Blaster or similar. Apply one coat of latex block filler by Benjamin Moore and two (2) coats acrylic top coat by Benjamin Moore. Colour by consultant. Existing floor hatch to remain, provide VCT finish. Modifiy existing LIT ceiling to suit new gypsum board partition wall at new electrical panel. Review and replace any damaged ceiling tiles to match existing. Remove existing paint finish down to bare concrete block where applicable using Bristle Blaster or similar. Apply one coat of latex block filler by Benjamin Moore and two (2) coats acrylic top coat by Benjamin Moore. Colour by consultant. Contractor to patch existing concrete floor construction c/w metal pan and reinforcing. Provide good finish. Refer to Structural addenda No.1 Existing floor hatch to remain, provide VCT finish. Review and replace any damaged ceiling tiles to match existing. Existing finishes to remain 175 Washroom ETR ETR ETR ETR ETR ETR Page 4

60 ROOM FINISH SCHEDULE - R1 Project: École Catholique St-Michel Building Envelope Upgrade Location: New Liskeard, Ontario Project No: WALL CEILING No. NAME FLOOR BASE MATERIAL FINISH MATERIAL FINISH HEIGHT REMARKS 178 Library CT RB, see remarks ETR Paint 178a Reception CT RB ETR, GB Paint GB, See remarks GB, LIT, See Remarks Paint Paint See remarks See remarks Contractor to remove existing ceiling mounted tile. Patch at light fixture locations and other penetrations restoring existing fire rating. At vaulted ceiling location, provide skim coat to cover existing textured finish. Provide new 9.5mm type 'X' gypsum board finish c/w tape, fill and paint throughout ceiling. For extent of vaulted ceiling and bulkhead locations and bulkhead heights, refer to reflected ceiling plan on drawing sheet 'A1.6'. Contractor to provide additional 14m² of carpet tile floor finish for Owner's use. Provide new rubber base at all existing shelving and millwork to remain. At existing wood trim around vaulted ceiling, contractor to prepare wood surfaces and provide new varnish finish throughout. Contractor to remove existing ceiling mounted tile. Patch at light fixture locations restoring existing fire rating. Provide new 9.5mm type 'X' gypsum board finish c/w tape, fill and paint finish throughout ceiling. For bulkheads above library reception desk, refer to reflected ceiling plan on drawing sheet 'A1.6'. For lay-in tile ceiling height, refer to reflected ceiling plan on drawing sheet 'A1.6'. 179 Boys W.R. VCT RB GB Paint LIT 2440mm 180 Girls W.R. VCT RB GB Paint LIT 2440mm Page 5

61 ROOM FINISH SCHEDULE - R1 Project: École Catholique St-Michel Building Envelope Upgrade Location: New Liskeard, Ontario Project No: WALL CEILING No. NAME FLOOR BASE MATERIAL FINISH MATERIAL FINISH HEIGHT REMARKS 181 H.C.W.R. VCT RB GB Paint LIT 2440mm 182 Sump VCT RB GB Paint LIT 2440mm Legend ETR: Existing to remain EX: Existing CT: Carpet Tile GB: Gypsum Board PT: Porcelain Tile LIT: Lay-in Tile VCT: Vinyl Composite Tile RB: Rubber Base Page 6

62

63

64

65 ADDENDUM Project: E.c. St-Michel Building Upgrade Addendum No.: Struc01 Location: Timmins No. of Pages: 1 WSP Project # PBK: Date: 17 Mar WSP Office (Timmins) The following change(s) in the Tender Documents are effective immediately. This Addendum forms part of the Contract Documents. ITEM DESCRIPTION Related to Structural 1.01 In the science classroom, patch the existing floor opening strips under the student sinks (4 separate locations) approximately 200 x 1300mm long each using the following procedure. a) Remove all loose concrete and laitance and trim opening to obtain even surface; b) Install 10M hilti bar dowels 150mm long using HIT HY200 embed 75mm with extension spaced at 300mm 300 c/c staggered along longitudinal direction; c) Provide plywood formwork and temporary shoring at underside of floor opening as required; d) Pour 25mPa concrete to fill floor opening. Perform cast in place concrete work in accordance with CSA A23.1/A23.2. e) Clean and roughen construction joint and apply CPD latex adhesive bonding agent strictly to manufacturer s instructions. END OF STRUCTURAL ADDENDUM WSP Canada Inc. 834 Mountjoy St. South, Timmins, ON P4N 7C5 Tel: Fax:

66 1

67

68

69

70

71 ADDENDUM Project: E.c. St-Michel Building Upgrade Addendum No.: 01 Location: Timmins No. of Pages: 4 WSP Project # PBK: Date: 17 Mar WSP Office (Timmins) The following change(s) in the Tender Documents are effective immediately. This Addendum forms part of the Contract Documents. ITEM DESCRIPTION Related to ELECTRICAL, 1.01 In Classroom 108, remove two (2) duplex receptacles and provide blank cover plates in south-west corner. Four (4) new power and data receptacles will be located on the south wall as shown on SKE In Classroom 110, four (4) new power and data receptacles will be located on the north wall as shown on SKE In Classroom 111, four (4) new power and data receptacles will be located on the north wall as shown on SKE-01. Provide one (1) new duplex receptacle and one (1) data receptacle above ceiling space in the south west corner as shown on SKE In Classroom 119, four (4) new power and data receptacles will be located on the north wall as shown on SKE In Classroom 128, four (4) new power and data receptacles will be located on the south wall as shown on SKE In Classroom 131, four (4) new power and data receptacles will be located on the north wall as shown on SKE In Classroom 132, the new projector will face the south wall as shown on SKE-03. END OF ELEC ADDENDUM WSP Canada Inc. 834 Mountjoy St. South, Timmins, ON P4N 7C5 Tel: Fax:

HAZARDOUS BUILDING MATERIALS SURVEY

HAZARDOUS BUILDING MATERIALS SURVEY HAZARDOUS BUILDING MATERIALS SURVEY Renovation Project Areas Social Services 178 Charlotte Street Peterborough, Ontario K9J 8S1 Presented to: City of Peterborough 500 George Street North Peterborough,

More information

PRE-DEMOLITION HAZARDOUS BUILDING MATERIALS SURVEY

PRE-DEMOLITION HAZARDOUS BUILDING MATERIALS SURVEY PRE-DEMOLITION HAZARDOUS BUILDING MATERIALS SURVEY Residential Property 1533 Sherbrooke Street Peterborough, Ontario K9K 0E6 Presented to: City of Peterborough 500 George Street North Peterborough, Ontario

More information

OWNER S DUTIES. Designated Substances on construction projects BEFORE CONTRACTS ARE FINALIZED, THE PROJECT OWNER MUST DO THE FOLLOWING

OWNER S DUTIES. Designated Substances on construction projects BEFORE CONTRACTS ARE FINALIZED, THE PROJECT OWNER MUST DO THE FOLLOWING In Ontario, section 30 of the Occupational Health and Safety Act requires that a project owner identify designated substances on the project and provide a list to prospective constructors before contracts

More information

WHY SHOULD PROJECT OWNERS PROVIDE A LIST OF DESIGNATED SUBSTANCES?

WHY SHOULD PROJECT OWNERS PROVIDE A LIST OF DESIGNATED SUBSTANCES? In Ontario, section 30 of the Occupational Health and Safety Act requires that a project owner identify designated substances on the project and provide a list to prospective constructors as part of the

More information

Pre-Demolition Hazardous Building Materials Survey

Pre-Demolition Hazardous Building Materials Survey Pre-Demolition Hazardous Building Materials Survey Commercial and Residential Property 212 and 210 Street East Peterborough, Ontario K9L 2A3 Presented to: City of Peterborough 500 George Street North Peterborough,

More information

DESIGNATED SUBSTANCES REPORT

DESIGNATED SUBSTANCES REPORT Replacement of Hangers Doors Ottawa, Ontario Page 1 of 4 PART 1 GENERAL 1.1 Regulatory Requirements.1 The following Designated Substances Report (DSR) was prepared in order to meet the owners or engineer

More information

PRE-RENOVATION SURVEY FOR DESIGNATED SUBSTANCES. Good Neighbours Club Community Centre 170 Jarvis Street Toronto, Ontario

PRE-RENOVATION SURVEY FOR DESIGNATED SUBSTANCES. Good Neighbours Club Community Centre 170 Jarvis Street Toronto, Ontario PRE-RENOVATION SURVEY FOR DESIGNATED SUBSTANCES Good Neighbours Club Community Centre 170 Jarvis Street Toronto, Ontario Presented to: Sara Reid Environmental Coordinator City of Toronto Facility Management

More information

ASBESTOS ASSESSMENT Curtis House Memorial University of Newfoundland St. John s, NL

ASBESTOS ASSESSMENT Curtis House Memorial University of Newfoundland St. John s, NL Project #: 13916 ASBESTOS ASSESSMENT Curtis House Memorial University of Newfoundland St. John s, NL Prepared for: Sheila Miller Director, Department of Health and Safety Memorial University of Newfoundland

More information

Lake Linden Hubbell Public Schools 2017 Facility Improvements

Lake Linden Hubbell Public Schools 2017 Facility Improvements ADDENDUM NO. 2 DATE: February 23, 2017 PROJECT: OWNER: BID DATE: Lake Linden Hubbell Public Schools 2017 Facility Improvements Lake Linden Hubbell Public Schools Tuesday, February 28, 2017 at 4:00 PM The

More information

Designated Substances Survey Guelph Greyhound Station 141 Macdonell Street Guelph, Ontario

Designated Substances Survey Guelph Greyhound Station 141 Macdonell Street Guelph, Ontario Designated Substances Survey Guelph Greyhound Station 141 Macdonell Street Guelph, Ontario Prepared By: R.J. Burnside & Associates Limited 292 Speedvale Avenue West Unit 7 Guelph ON N1H 1C4 July 2010 File

More information

ASBESTOS AND LEAD PAINT INSPECTION REPORT

ASBESTOS AND LEAD PAINT INSPECTION REPORT ASBESTOS AND LEAD PAINT INSPECTION REPORT for the former HENRY SILER SCHOOL 502 WEST THIRD STREET SILER CITY, NC March 2012 prepared by Herrick Engineering, Inc. 526 Lochness Lane Cary, NC 27511 (919)

More information

PROJECT NO REPORT TO CITY OF STRATFORD ASBESTOS CONTAINING MATERIALS SURVEY ROW HOUSES STRATFORD, ONTARIO CONDUCTED BY:

PROJECT NO REPORT TO CITY OF STRATFORD ASBESTOS CONTAINING MATERIALS SURVEY ROW HOUSES STRATFORD, ONTARIO CONDUCTED BY: PROJECT NO. 1197 REPORT TO CITY OF STRATFORD ON ASBESTOS CONTAINING MATERIALS SURVEY ROW HOUSES STRATFORD, ONTARIO CONDUCTED BY: 1099 KINGSTON ROAD, SUITE 260 PICKERING, ONTARIO L1V 1B5 Tel: (416) 410-4333

More information

PRE-DEMOLITION HAZARDOUS BUILDING MATERIALS SURVEY

PRE-DEMOLITION HAZARDOUS BUILDING MATERIALS SURVEY PRE-DEMOLITION HAZARDOUS BUILDING MATERIALS SURVEY Residential Property 513 Riverside Drive Peterborough, Ontario K9J 3Y9 Presented to: The City of Peterborough 500 George Street North Peterborough, Ontario

More information

ASBESTOS ASSESSMENT Cartier Court Memorial University of Newfoundland St. John s, NL

ASBESTOS ASSESSMENT Cartier Court Memorial University of Newfoundland St. John s, NL Project #: 13916 ASBESTOS ASSESSMENT Cartier Court Memorial University of Newfoundland St. John s, NL Prepared for: Sheila Miller Director, Department of Health and Safety Memorial University of Newfoundland

More information

ASBESTOS INSPECTION REPORT 3801 HARNEY STREET OMAHA, NEBRASKA 68132

ASBESTOS INSPECTION REPORT 3801 HARNEY STREET OMAHA, NEBRASKA 68132 ASBESTOS INSPECTION REPORT 3801 HARNEY STREET OMAHA, NEBRASKA 68132 Prepared For: Women s Center for Advancement 222 South 29 th Street Omaha, Nebraska 68131 June 20, 2016 Prepared By: New Horizons Enterprises,

More information

HOL-11 Exterior Pipe wrap Lagging (fiber) PLM None detected. HOL-09 Room 10 - Floor Tile, Grey 12x12 PLM None detected

HOL-11 Exterior Pipe wrap Lagging (fiber) PLM None detected. HOL-09 Room 10 - Floor Tile, Grey 12x12 PLM None detected Laboratory results - Asbestos School Sample no. Sample Location Material Sample Type Result Holbrook Elementary HOL-01 Room 12 Floor - Linoleum Tan Linoleum PLM 30% Chrysotile Floor tile PLM None detected

More information

PRE-DEMOLITION HAZARDOUS BUILDING MATERIALS SURVEY

PRE-DEMOLITION HAZARDOUS BUILDING MATERIALS SURVEY PRE-DEMOLITION HAZARDOUS BUILDING MATERIALS SURVEY Residential Property 670 Reid Street Peterborough, Ontario K9H 3R9 Presented to: The City of Peterborough 500 George Street North Peterborough, Ontario

More information

ASBESTOS AND LEAD PAINT BUILDING MATERIALS SURVEY FOR: C-CORE BUILDING MEMORIAL UNIVERSITY OF NEWFOUNDLAND

ASBESTOS AND LEAD PAINT BUILDING MATERIALS SURVEY FOR: C-CORE BUILDING MEMORIAL UNIVERSITY OF NEWFOUNDLAND ASBESTOS AND LEAD PAINT BUILDING MATERIALS SURVEY FOR: C-CORE BUILDING MEMORIAL UNIVERSITY OF NEWFOUNDLAND Prepared for: Memorial University of Newfoundland St. John s, NL Pinchin LeBlanc Environmental

More information

FINAL REPORT. Asbestos-Containing Building Material Assessment. Toronto Catholic District School Board

FINAL REPORT. Asbestos-Containing Building Material Assessment. Toronto Catholic District School Board FINAL REPORT Asbestos-Containing Building Material Assessment Toronto Catholic District School Board St. Jerome Catholic School, 111 Sharpecroft Blvd. Toronto, Ontario PROJECT NO. 1025760 PROJECT NO. 1025760

More information

Designated Substance Sampling, 1631 Queen Street East, Toronto, ON

Designated Substance Sampling, 1631 Queen Street East, Toronto, ON April 27, 2018 Meaghan Aldcroft Environmental Coordinator City of Toronto, Corporate Services Facilities Management Metro Hall, 55 John Street Toronto ON, M5V 3C6 Re: Designated Substance Sampling, 1631

More information

FINAL REPORT. Asbestos-Containing Building Material Assessment

FINAL REPORT. Asbestos-Containing Building Material Assessment FINAL REPORT Asbestos-Containing Building Material Assessment Toronto Catholic District School Board Nativity of Our Lord Catholic School 35 Saffron Crescent Etobicoke, Ontario PROJECT NO. 1025760 PROJECT

More information

FINAL REPORT. Asbestos-Containing Building Material Assessment. Toronto Catholic District School Board

FINAL REPORT. Asbestos-Containing Building Material Assessment. Toronto Catholic District School Board FINAL REPORT Asbestos-Containing Building Material Assessment Toronto Catholic District School Board Santa Maria Catholic School, 25 Avon Avenue Toronto, Ontario PROJECT NO. 1025760 PROJECT NO. 1025760

More information

Crothers Environmental Group, LLC

Crothers Environmental Group, LLC , LLC Morrisville, Vermont 05661 Phone 802-888-1936 info@crothersiaq.com June 26, 2009 Mr. Joe Aja, Project Engineer State of Vermont - Department of Buildings & General Services 5 Perry Street, Suite

More information

LIMITED ASBESTOS ASSESSMENT

LIMITED ASBESTOS ASSESSMENT LIMITED ASBESTOS ASSESSMENT FORMER DORAN MILL SITE 404 POLKVILLE ROAD SHELBY, NORTH CAROLINA 28150 ECS PROJECT NO. 49:4683 FOR CLEVELAND COUNTY ECONOMIC DEVELOPMENT JUNE 30, 2017 June 30, 2017 Mr. Matt

More information

The following non-friable asbestos products were identified at the site:

The following non-friable asbestos products were identified at the site: April 27, 2018 Ms. Jessica Kenney Boulder Housing Partners 4800 Broadway Street Boulder, Colorado 80304 RE: Limited Asbestos-Containing Building Materials Survey Canyon Point Apartments First Floor 700

More information

Ontario Inc. March 10, Jardin Des Sapins Orleans, ON

Ontario Inc. March 10, Jardin Des Sapins Orleans, ON 2150 Thurston Drive, Suite 203 Ottawa, Ontario K1G 5T9 Tel.: (613) 748-1415 or 1-877-378-3745 Fax: (613) 748-1356 E-Mail: ottawa@dstgroup.com 2357976 Ontario Inc. March 10, 2014 1698 Jardin Des Sapins

More information

DESIGNATED SUBSTANCE SURVEY. Laurentian University Science Building 2B MOD Project Sudbury, Ontario

DESIGNATED SUBSTANCE SURVEY. Laurentian University Science Building 2B MOD Project Sudbury, Ontario DESIGNATED SUBSTANCE SURVEY Laurentian University Science Building 2B MOD Project Sudbury, Ontario Submitted to: Laurentian University 935 Ramsey Lake Road Sudbury, Ontario P3E 2C6 REVISED REPORT Report

More information

FINAL REPORT. Asbestos-Containing Building Material Assessment. Toronto Catholic District School Board

FINAL REPORT. Asbestos-Containing Building Material Assessment. Toronto Catholic District School Board FINAL REPORT Asbestos-Containing Building Material Assessment Toronto Catholic District School Board Loretto Abbey Secondary School 101 Mason Boulevard Toronto, ONTARIO PROJECT NO. 1025760 PROJECT NO.

More information

TRANSIT STORAGE & ADMINISTRATION BUILDING ASBESTOS SURVEY REPORT

TRANSIT STORAGE & ADMINISTRATION BUILDING ASBESTOS SURVEY REPORT TRANSIT STORAGE & ADMINISTRATION BUILDING ASBESTOS SURVEY REPORT April 2014 Prepared For: City of Saskatoon Infrastructure Services Department 1101 Avenue P North, Saskatoon SK, Canada S7L 7K6 Attn: Brent

More information

InAIR Environmental Ltd.

InAIR Environmental Ltd. InAIR Environmental Ltd. Final Report Limited Designated Substances Survey Algonquin College, Building J Dental Clinic Ottawa, Ontario Survey Performed: February 2014 Prepared for: Mr. Len Tremblay P.Eng.,

More information

Limited Asbestos Demolition Survey

Limited Asbestos Demolition Survey Limited Asbestos Demolition Survey Limited Asbestos Demolition Survey Former Fire Station Facility 25 to 45 S. Orlando Avenue Cocoa Beach, Florida Client: City of Cocoa Beach Public Works Department 1600

More information

ASBESTOS SURVEY. Old Detective s Building Wadesboro, NC INSPECTED &PREPARED BY:

ASBESTOS SURVEY. Old Detective s Building Wadesboro, NC INSPECTED &PREPARED BY: ASBESTOS SURVEY Old Detective s Building Wadesboro, NC PREPARED FOR: Alex Sewell Town Manager Town of Wadesboro 124 E. Wade Street Wadesboro, NC Date of Inspection September 28, 2016 Date of Report October

More information

DESIGNATED SUBSTANCES SURVEY 30 Carrier Drive Toronto, ON

DESIGNATED SUBSTANCES SURVEY 30 Carrier Drive Toronto, ON 385 The West Mall Toronto, ON, M9C 1E7 416-479-4462 www.peritusenv.com Peritus File # 22-21-181617 February 28, 2018 DESIGNATED SUBSTANCES SURVEY 30 Carrier Drive Toronto, ON Prepared for: FCAPX ONTARIO

More information

BUILDING ENVIRONMENTAL AUDIT. Good Neighbours Club Community Centre 170 Jarvis Street Toronto, Ontario

BUILDING ENVIRONMENTAL AUDIT. Good Neighbours Club Community Centre 170 Jarvis Street Toronto, Ontario BUILDING ENVIRONMENTAL AUDIT Good Neighbours Club Community Centre 170 Jarvis Street Toronto, Ontario Presented to: Tracey Smith City of Toronto Corporate Services Facilities & Real Estate Division Metro

More information

HAZARDOUS MATERIAL INSPECTION

HAZARDOUS MATERIAL INSPECTION HAZARDOUS MATERIAL INSPECTION Former School Building 16 Dewey Ave. Sandwich, MA 02563 Prepared For: Town of Sandwich 130 Main Street Sandwich, MA 02563 Attn.: Ted Hamilton Facilities Director April 20,

More information

Asbestos Inspection Cover Letter

Asbestos Inspection Cover Letter Asbestos Inspection Cover Letter Date Issued: January 27, 2016 Site Name/Location Residential Structure 4 Cauthen Street Rock Hill, South Carolina Asbestos Inspection Performed For Hank Williams Right

More information

FINAL REPORT. Asbestos-Containing Building Material Assessment

FINAL REPORT. Asbestos-Containing Building Material Assessment FINAL REPORT Asbestos-Containing Building Material Assessment Toronto Catholic District School Board St. Maurice Catholic School, 45 Kingsview Boulevard Etobicoke, Ontario PROJECT NO. 1025760 PROJECT NO.

More information

REAL ESTATE & FACILITIES MANAGEMENT Facilities Planning & Development

REAL ESTATE & FACILITIES MANAGEMENT Facilities Planning & Development REAL ESTATE & FACILITIES MANAGEMENT Facilities Planning & Development Hazardous Materials Survey of 1710 East Kent Ave, Vancouver, BC Sampling Date: 2017-02-24 and 2017-03-10 Address: 1710 East Kent Ave,

More information

Test Report: Asbestos Analysis of Bulk Materials by PLM via the NY State ELAP Method

Test Report: Asbestos Analysis of Bulk Materials by PLM via the NY State ELAP Method 031214474 Phone: (518) 453-0146 Received: 05/11/12 9:59 AM Analysis Date: Project: Test Report: Analysis of Bulk Materials by PLM via the NY State ELAP 198.1 Method Non- Sample Description Appearance %

More information

AHERA/NESHAP ASBESTOS INSPECTION REPORT 460 FEWELL STREET ROCK HILL, SC. CLIENT: City of Rock Hill P.O. Box Rock Hill, SC 29731

AHERA/NESHAP ASBESTOS INSPECTION REPORT 460 FEWELL STREET ROCK HILL, SC. CLIENT: City of Rock Hill P.O. Box Rock Hill, SC 29731 AHERA/NESHAP ASBESTOS INSPECTION REPORT 460 FEWELL STREET ROCK HILL, SC CLIENT: City of Rock Hill P.O. Box 11706 Rock Hill, SC 29731 LOCATION: 460 Fewell Street Rock Hill, SC 29730 DATE OF INSPECTION:

More information

PRE-DEMOLITION HAZARDOUS BUILDING MATERIALS SURVEY

PRE-DEMOLITION HAZARDOUS BUILDING MATERIALS SURVEY PRE-DEMOLITION HAZARDOUS BUILDING MATERIALS SURVEY Montessori Day Care 844 Park Street South Peterborough, Ontario K9J 3T8 Presented to: The City of Peterborough 500 George Street North Peterborough, Ontario

More information

FINAL REPORT. Asbestos-Containing Building Material Assessment. Toronto Catholic District School Board

FINAL REPORT. Asbestos-Containing Building Material Assessment. Toronto Catholic District School Board FINAL REPORT Asbestos-Containing Building Material Assessment Toronto Catholic District School Board Corpus Christi Catholic School 4 Edgewood Avenue Toronto, Ontario PROJECT NO. 05760 PROJECT NO. 05760

More information

Asbestos Inventory Survey of James Anderson Learning Centre, Avenue, Langley (Formerly Langley Fundamental Middle School)

Asbestos Inventory Survey of James Anderson Learning Centre, Avenue, Langley (Formerly Langley Fundamental Middle School) October 31, 2016 200753 AIS R1 James Anderson Learning Centre School District #35 (Langley) 20260 64 th Avenue Langley, BC V2Y 1N3 E mail: Attention: Reference: KWagner@sd35.bc.ca Karen Wagner Asbestos

More information

Roseville OFFICE* 1911 Douglas Blvd, ste * Roseville, CA Phone (916) * Fax (916) *

Roseville OFFICE* 1911 Douglas Blvd, ste * Roseville, CA Phone (916) * Fax (916) * Roseville OFFICE* 1911 Douglas Blvd, ste 85-349* Roseville, CA 95661 Phone (916) 628-0050 * Fax (916) 781-6837 * www.hazmanage.com Camino Union Elementary School District Maintenance Building Demolition

More information

REASSESSMENT SURVEY OF ASBESTOS - CONTAINING MATERIALS ANNE HATHAWAY DAYCARE CENTRE 103 Bruce Street Stratford, Ontario

REASSESSMENT SURVEY OF ASBESTOS - CONTAINING MATERIALS ANNE HATHAWAY DAYCARE CENTRE 103 Bruce Street Stratford, Ontario REASSESSMENT SURVEY OF ASBESTOS - CONTAINING MATERIALS ANNE HATHAWAY DAYCARE CENTRE 103 Bruce Street Stratford, Ontario June 30 th, 2014 Prepared for: Debbie Kindler - Supervisor 103 Bruce Street Stratford,

More information

FINAL REPORT. Asbestos-Containing Building Material Assessment. Toronto Catholic District School Board

FINAL REPORT. Asbestos-Containing Building Material Assessment. Toronto Catholic District School Board FINAL REPORT Asbestos-Containing Building Material Assessment Toronto Catholic District School Board St. Sebastian Catholic School 717 Brock Avenue Toronto, Ontario PROJECT NO. 1025760 PROJECT NO. 1025760

More information

patersongroup 1.0 BACKGROUND 2.0 SITE INSPECTION AND OBSERVATIONS Consulting Engineers November 15, 2016 File: PE3915-LET.01

patersongroup 1.0 BACKGROUND 2.0 SITE INSPECTION AND OBSERVATIONS Consulting Engineers November 15, 2016 File: PE3915-LET.01 patersongroup November 15, 2016 File: PE3915-LET.01 Shepherds of Good Hope 233 Murray Street Ottawa, Ontario K1N 5M9 Attention: Mr. Rob Searle Consulting Engineers 154 Colonnade Road South Ottawa, Ontario

More information

AHERA/NESHAP ASBESTOS INSPECTION REPORT. CLIENT: City of Florence 324 West Evans Street Florence, SC (843)

AHERA/NESHAP ASBESTOS INSPECTION REPORT. CLIENT: City of Florence 324 West Evans Street Florence, SC (843) AHERA/NESHAP ASBESTOS INSPECTION REPORT CLIENT: City of Florence 324 West Evans Street Florence, SC 29501-3430 (843) 665-3173 LOCATION: 558 N. Alexander Street Florence, SC 29501 DATE OF INSPECTION: September

More information

Asbestos Assessment East Facilities Services 97 Railside Road, Toronto, Ontario

Asbestos Assessment East Facilities Services 97 Railside Road, Toronto, Ontario Asbestos Assessment East Facilities Services 97 Railside Road, Toronto, Ontario Prepared for: Toronto Catholic District School Board 80 Sheppard Avenue East Toronto, Ontario, M2N 6E8 Attention: Kathleen

More information

ASBESTOS AND LEAD PAINT BUILDING MATERIALS SURVEY FOR: COUGHLAN COLLEGE MEMORIAL UNIVERSITY OF NEWFOUNDLAND

ASBESTOS AND LEAD PAINT BUILDING MATERIALS SURVEY FOR: COUGHLAN COLLEGE MEMORIAL UNIVERSITY OF NEWFOUNDLAND ASBESTOS AND LEAD PAINT BUILDING MATERIALS SURVEY FOR: COUGHLAN COLLEGE MEMORIAL UNIVERSITY OF NEWFOUNDLAND Prepared for: Memorial University of Newfoundland St. John s, NL Pinchin LeBlanc Environmental

More information

ASBESTOS INSPECTION REPORT Completed in accordance with 40 CFR, and (a)(4)

ASBESTOS INSPECTION REPORT Completed in accordance with 40 CFR, and (a)(4) ASBESTOS INSPECTION REPORT Completed in accordance with 40 CFR, 763.86 and 763.85(a)(4) Assessment Completed for Clint Moore, ASLA Planning, Research and Development City of Florence 324 West Evans Street

More information

TRANSIT REPAIR TERMINAL NORTH BUILDING ASBESTOS SURVEY REPORT

TRANSIT REPAIR TERMINAL NORTH BUILDING ASBESTOS SURVEY REPORT TRANSIT REPAIR TERMINAL NORTH BUILDING ASBESTOS SURVEY REPORT April 2014 Prepared For: City of Saskatoon Infrastructure Services Department 1101 Avenue P North, Saskatoon SK, Canada S7L 7K6 Attn: Brent

More information

www.allasbestos.co.nz P O Box 30836 Lower Hutt Phone 045674881 Fax 045678488 afil@xtra.co.nz 06/12/2014 Victoria University C/o Wareham Cameron and co PO Box 3531 WELLINGTON Attn: Andrew Croskery Asbestos

More information

Hazardous Materials Inspection Services Seekonk Public Library, Seekonk, MA

Hazardous Materials Inspection Services Seekonk Public Library, Seekonk, MA January 10, 2017 Mr. Christopher Blessen Principal Tappe & Associates 6 Edgerly Place Boston, MA 02116 Reference: Hazardous Materials Inspection Services Seekonk Public Library, Seekonk, MA Dear Mr. Blessen:

More information

ANNUAL SURVEY FOR DESIGNATED SUBSTANCES AND HAZARDOUS MATERIALS

ANNUAL SURVEY FOR DESIGNATED SUBSTANCES AND HAZARDOUS MATERIALS ANNUAL SURVEY FOR DESIGNATED SUBSTANCES AND HAZARDOUS MATERIALS East York Civic Centre 850 Coxwell Avenue Toronto, Ontario Presented to: Sara Reid City of Toronto Corporate Services Facilities Management

More information

ETERNAL MEMORIALS ASBESTOS SURVEY REPORT

ETERNAL MEMORIALS ASBESTOS SURVEY REPORT ETERNAL MEMORIALS ASBESTOS SURVEY REPORT February 2014 Prepared For: City of Saskatoon Infrastructure Services Department 1101 Avenue P North, Saskatoon SK, Canada S7L 7K6 Attn: Brent Anderson Prepared

More information

NORWELL PUBLIC LIBRARY 64 South St, Norwell, MA 02061

NORWELL PUBLIC LIBRARY 64 South St, Norwell, MA 02061 INSPECTION REPORT FOR HAZARDOUS BUILDING MATERIALS NORWELL PUBLIC LIBRARY 64 South St, Norwell, MA 02061 Prepared For: Mr. Rick Pomroy Pomroy Associates LLC Village Place 448 Turnpike Street, Suite 1-1

More information

November 12, Mr. Derek Sandgren Helm Properties 1520 Butte House Road, Suite 400 Yuba City, California

November 12, Mr. Derek Sandgren Helm Properties 1520 Butte House Road, Suite 400 Yuba City, California November 12, 2014 Mr. Derek Sandgren Helm Properties 1520 Butte House Road, Suite 400 Yuba City, California 95993-2240 RE: Pre-Renovation Asbestos Survey Report 5862 Rupert Avenue, Marysville, California

More information

University of South Carolina State Project No: H Wardlaw AHU-2 Replacement

University of South Carolina State Project No: H Wardlaw AHU-2 Replacement University of South Carolina State Project No: H27-6117 Wardlaw AHU-2 Replacement Addendum One March 14, 2017 NOTE: The following amendments, additions, and deletions shall be made to the Construction

More information

Asbestos Inventory Survey of Glenwood Elementary, Avenue, Langley, BC

Asbestos Inventory Survey of Glenwood Elementary, Avenue, Langley, BC October 25, 2016 200753 AIS R1 Glenwood Elementary School District #35 (Langley) 20260 64 th Avenue Langley, BC V2Y 1N3 E mail: Attention: Reference: KWagner@sd35.bc.ca Karen Wagner Asbestos Inventory

More information

May 17, 2012 KAS PROJECT # PREPARED FOR: Stantec, Inc. 55 Green Mountain Drive South Burlington, VT P.O. BOX 787 WILLISTON, VT 05495

May 17, 2012 KAS PROJECT # PREPARED FOR: Stantec, Inc. 55 Green Mountain Drive South Burlington, VT P.O. BOX 787 WILLISTON, VT 05495 ASBESTOS INSPECTION REPORT 13, 57 & 72 Dumont Avenue, 23 Maryland Street, 2 & 6 Patrick Street, 392 White Street and 6 Elizabeth Street South Burlington, VT 05403 AIP 87 May 17, 2012 KAS PROJECT # 509110229

More information

Asbestos Survey Report University of Alaska Anchorage SSB Building-Mechanical Rooms (1 st, 3 rd Floors & Room 205) Prepared for:

Asbestos Survey Report University of Alaska Anchorage SSB Building-Mechanical Rooms (1 st, 3 rd Floors & Room 205) Prepared for: Asbestos Survey Report University of Alaska Anchorage SSB Building-s (1 st, 3 rd Floors & Room 205) Prepared for: University of Alaska Anchorage 3211Providence Drive Anchorage, AK 99508 Ms. Patricia Baum

More information

Asbestos Elevator Industry Workshop November 25, 2015

Asbestos Elevator Industry Workshop November 25, 2015 Asbestos Elevator Industry Workshop November 25, 2015 BOB SWING CONTACT INFO EMAIL: Bob.Swing@ThyssenKrupp.com Phone: 604-499-5714 SOME ASBESTOS-CONTAINING MATERIALS Cement Pipes Cement Wallboard Cement

More information

ASBESTOS AND LEAD PAINT BUILDING MATERIALS SURVEY FOR: QUEEN ELIZABETH II LIBRARY MEMORIAL UNIVERSITY OF NEWFOUNDLAND

ASBESTOS AND LEAD PAINT BUILDING MATERIALS SURVEY FOR: QUEEN ELIZABETH II LIBRARY MEMORIAL UNIVERSITY OF NEWFOUNDLAND ASBESTOS AND LEAD PAINT BUILDING MATERIALS SURVEY FOR: QUEEN ELIZABETH II LIBRARY MEMORIAL UNIVERSITY OF NEWFOUNDLAND Prepared for: Memorial University of Newfoundland St. John s, NL Pinchin LeBlanc Environmental

More information

SanAir Technologies Laboratory. Analysis Report. Rockbridge Environmental Consulting, Inc.

SanAir Technologies Laboratory. Analysis Report. Rockbridge Environmental Consulting, Inc. SanAir Technologies Laboratory Analysis Report prepared for Rockbridge Environmental Consulting, Inc. 10/26/2016 Project #: SanAir ID#: 804.897.1177 www.sanair.com Page 1 of 17 October 26, 2016 SanAir

More information

ASBESTOS AND HAZARDOUS MATERIAL INVESTIGATION REPORT

ASBESTOS AND HAZARDOUS MATERIAL INVESTIGATION REPORT ASBESTOS AND HAZARDOUS MATERIAL INVESTIGATION REPORT FOR Detroit, MI 48238 Contract 09302013A N.P. # 03282014E Prepared for: Michigan Land Bank Cadillac Place 3022 West Grand Blvd., Suite 4-600 Detroit,

More information

Hazardous Building Materials Assessment St. Louis Elementary School 75 Allen Street Waterloo, Ontario

Hazardous Building Materials Assessment St. Louis Elementary School 75 Allen Street Waterloo, Ontario St. Louis Elementary School 75 Allen Street Waterloo, Ontario Prepared for: City of Waterloo 500 Parkside Drive Waterloo, Ontario Attention: Jean Starchuk 79146 October 31, 2012 Pinchin Environmental Ltd.

More information

POTENTIALLY HAZARDOUS MATERIALS BUILDING INSPECTION REPORT. for. Barton Malow/Clark MSU Spartan Stadium 58 Shaw Lane East Lansing, Michigan

POTENTIALLY HAZARDOUS MATERIALS BUILDING INSPECTION REPORT. for. Barton Malow/Clark MSU Spartan Stadium 58 Shaw Lane East Lansing, Michigan POTENTIALLY HAZARDOUS MATERIALS BUILDING INSPECTION REPORT for Barton Malow/Clark MSU Spartan Stadium 58 Shaw Lane East Lansing, Michigan 48824-1215 at Michigan State University I.M. West Building East

More information

FINAL REPORT. Asbestos-Containing Building Material Assessment

FINAL REPORT. Asbestos-Containing Building Material Assessment FINAL REPORT Asbestos-Containing Building Material Assessment Toronto Catholic District School Board St. Martin de Porres Catholic School, 230 Morningside Avenue Scarborough, Ontario PROJECT NO. 1025760

More information

HAZARDOUS BUILDING MATERIALS SURVEY

HAZARDOUS BUILDING MATERIALS SURVEY HAZARDOUS BUILDING MATERIALS SURVEY Parking Garage Rehabilitation Project King Street Parking Garage 150 King Street Peterborough, Ontario K9J 2R9 Presented to: The City of Peterborough 500 George Street

More information

ASBESTOS REINSPECTION SURVEY REPORT GENERAL SERVICES ADMINISTRATION AUBURN ADMINISTRATION BUILDING BUILDING WA0811KA AUBURN, WASHINGTON

ASBESTOS REINSPECTION SURVEY REPORT GENERAL SERVICES ADMINISTRATION AUBURN ADMINISTRATION BUILDING BUILDING WA0811KA AUBURN, WASHINGTON ASBESTOS REINSPECTION SURVEY REPORT GENERAL SERVICES ADMINISTRATION AUBURN ADMINISTRATION BUILDING BUILDING WA0811KA AUBURN, WASHINGTON May 23, 2007 Prepared for: Mr. Ron Smith GSA 400-15 th Street SW

More information

HISTORICAL RESEARCH FOR DESIGNATED PRE-MODERNIZATION ASBESTOS AND LEAD SURVEY REPORT DEL MAR HIGH SCHOOL 1224 DEL MAR AVENUE SAN JOSÉ, CA 95128

HISTORICAL RESEARCH FOR DESIGNATED PRE-MODERNIZATION ASBESTOS AND LEAD SURVEY REPORT DEL MAR HIGH SCHOOL 1224 DEL MAR AVENUE SAN JOSÉ, CA 95128 HISTORICAL RESEARCH FOR DESIGNATED PRE-MODERNIZATION ASBESTOS AND LEAD SURVEY REPORT DEL MAR HIGH SCHOOL 1224 DEL MAR AVENUE SAN JOSÉ, CA 95128 BUILDING A ADMINISTRATION AND LIBRARY SECTIONS CUHSD DEL

More information

ASBESTOS ASSESSMENT Science Building Memorial University of Newfoundland St. John s, NL

ASBESTOS ASSESSMENT Science Building Memorial University of Newfoundland St. John s, NL Project #: 14610 ASBESTOS ASSESSMENT Science Building Memorial University of Newfoundland St. John s, NL Prepared for: Tina Giles-Murphy Director, Department of Health and Safety Memorial University of

More information

ASBESTOS SURVEY REPORT 840 MANTOLOKING ROAD, APT NO. 3 BRICK, NEW JERSEY SRP D.003

ASBESTOS SURVEY REPORT 840 MANTOLOKING ROAD, APT NO. 3 BRICK, NEW JERSEY SRP D.003 PARS Environmental Inc. 500 Horizon Drive Suite 540 Robbinsville, NJ 08691 Tel: 609-890-7277 Fax: 609-890-9116 March 17, 2014 Mr. Chris DeBruyn Delaware Valley Estimating Gilbane Building Company 4814

More information

HART ENVIRONMENTAL RESOURCES

HART ENVIRONMENTAL RESOURCES HART ENVIRONMENTAL RESOURCES 262 Hedge Dr. Springfield, OH 45504 (937) 325-8777 (937) 324-0288 FAX ASBESTOS INSPECTION REPORT 143 N. Marion St. Dayton, OH 45417 PREPARED FOR: Mr. Dennis Zimmer Montgomery

More information

FINAL REPORT. Asbestos-Containing Building Material Assessment. Toronto Catholic District School Board

FINAL REPORT. Asbestos-Containing Building Material Assessment. Toronto Catholic District School Board FINAL REPORT Asbestos-Containing Building Material Assessment Toronto Catholic District School Board Regina Pacis Catholic School 45 Norfinch Drive North York, Ontario PROJECT NO. 1025760 PROJECT NO. 1025760

More information

J July 12, Asbestos Assessment and Lead Paint Screening 77 Maple Street Springfield, Massachusetts

J July 12, Asbestos Assessment and Lead Paint Screening 77 Maple Street Springfield, Massachusetts July 12, 2018 Asbestos Assessment and Lead Paint Screening 77 Maple Street Springfield, Massachusetts PREPARED FOR: 29 Elliot Street Springfield, Massachusetts 01105 PREPARED BY: O Reilly, Talbot & Okun

More information

Assessment Completed by: Asbestos Inspections, LLC 4686 Pee Dee Highway Conway, South Carolina (843)

Assessment Completed by: Asbestos Inspections, LLC 4686 Pee Dee Highway Conway, South Carolina (843) ASBESTOS INSPECTION REPORT 1816 PRINCE STREET Georgetown, South Carolina Asbestos Inspections, LLC Project # 2017-48 Performed in general accordance with SCDHEC regulation 61-86.1 along with OSHA regulation

More information

ADDENDUM NO. 1 TENDER CALL NO FOR THE RENOVATION OF BUILDING B AT 320 BERING AVE., TORONTO.

ADDENDUM NO. 1 TENDER CALL NO FOR THE RENOVATION OF BUILDING B AT 320 BERING AVE., TORONTO. Michael Pacholok Director Purchasing and Materials Management Division City Hall, 18 th Floor, West Tower 100 Queen Street West Toronto, Ontario M5H 2N2 Joanne Kehoe Manager Construction Services December

More information

AHERA/NESHAP ASBESTOS INSPECTION REPORT. CLIENT: City of Florence 324 West Evans Street Florence, SC (843)

AHERA/NESHAP ASBESTOS INSPECTION REPORT. CLIENT: City of Florence 324 West Evans Street Florence, SC (843) AHERA/NESHAP ASBESTOS INSPECTION REPORT CLIENT: City of Florence 324 West Evans Street Florence, SC 29501-3430 (843) 665-3173 LOCATION: 814 Gladstone Street Florence, SC 29501 DATE OF INSPECTION: September

More information

ASSESSMENT OF ASBESTOS-CONTAINING BUILDING MATERIALS

ASSESSMENT OF ASBESTOS-CONTAINING BUILDING MATERIALS ASSESSMENT OF ASBESTOS-CONTAINING BUILDING MATERIALS KERR HALL NORTH KHN 113A LABORATORY RENOVATION PROJECT RYERSON UNIVERSITY 350 VICTORIA STREET, 2 ND FLOOR TORONTO, ONTARIO M5B 2K3 Prepared for: Mr.

More information

Investigation Remediation Citation Drive, Suite 100 Compliance Restoration Brighton, MI 48116

Investigation Remediation Citation Drive, Suite 100 Compliance Restoration Brighton, MI 48116 Investigation Remediation 10448 Citation Drive, Suite 100 Compliance Restoration Brighton, MI 48116 Mailing Address: P.O. Box 2160 Brighton, MI 48116-2160 800 395-ASTI Fax: 810.225.3800 www.asti-env.com

More information

LIMITED POTENTIALLY HAZARDOUS MATERIAL BUILDING INSPECTION REPORT AND ASBESTOS BUILDING INSPECTION REPORT. for

LIMITED POTENTIALLY HAZARDOUS MATERIAL BUILDING INSPECTION REPORT AND ASBESTOS BUILDING INSPECTION REPORT. for LIMITED POTENTIALLY HAZARDOUS MATERIAL BUILDING INSPECTION REPORT AND ASBESTOS BUILDING INSPECTION REPORT for Michigan State University Physical Plant Division Engineering and Architectural Services Department

More information

City of Saskatoon #9 450 Ontario Avenue Asbestos Survey Report

City of Saskatoon #9 450 Ontario Avenue Asbestos Survey Report City of Saskatoon #9 450 Ontario Avenue Asbestos Survey Report April 2016 Prepared For: City of Saskatoon Support Services 222 3 rd Avenue North, Saskatoon, SK. S7K 0J5 Attn: Lana Dodds Prepared By: Bersch

More information

ASBESTOS SURVEY WARNER ROBINS HOUSING AUTHORITY PROJECT SITE GA06P WARNER ROBINS, GEORGIA. December 28, 2005

ASBESTOS SURVEY WARNER ROBINS HOUSING AUTHORITY PROJECT SITE GA06P WARNER ROBINS, GEORGIA. December 28, 2005 ASBESTOS SURVEY WARNER ROBINS HOUSING AUTHORITY PROJECT SITE GA06P160003 WARNER ROBINS, GEORGIA Prepared for: Warner Robins Housing Authority Ms. Charles Alexander Prepared by: Holley Consultants, Inc.

More information

FINAL REPORT. Asbestos-Containing Building Material Assessment

FINAL REPORT. Asbestos-Containing Building Material Assessment FINAL REPORT Asbestos-Containing Building Material Assessment Toronto Catholic District School Board Blessed Trinity Catholic School, 3205 Bayview Avenue North York, Ontario PROJECT NO. 1025760 PROJECT

More information

McMaster University Asbestos Awareness Environmental & Occupational Health Support Services Gilmour Hall Room 304

McMaster University Asbestos Awareness Environmental & Occupational Health Support Services Gilmour Hall Room 304 The Campaign for McMaster University The Campaign for McMaster University McMaster University Asbestos Awareness Environmental & Occupational Health Support Services Gilmour Hall Room 304 The Campaign

More information

DESIGNATED SUBSTANCE SURVEY REPORT PERTH & DISTRICT COLLEGIATE INSTITUTE PERTH, ONTARIO

DESIGNATED SUBSTANCE SURVEY REPORT PERTH & DISTRICT COLLEGIATE INSTITUTE PERTH, ONTARIO DESIGNATED SUBSTANCE SURVEY REPORT PERTH & DISTRICT COLLEGIATE INSTITUTE PERTH, ONTARIO Prepared for: Upper Canada District School Board 225 Central Avenue West Brockville, Ontario K6V 5X1 Pinchin Environmental

More information

Hazardous Building Materials Assessment 240 Manor Road East, Toronto, Ontario

Hazardous Building Materials Assessment 240 Manor Road East, Toronto, Ontario 1 of 54 Hazardous Building Materials Assessment 240 Manor Road East, Toronto, Ontario Prepared for: City of Toronto 55 John Street, 2nd Floor Toronto, Ontario Attention: Sara Reid Environmental Project

More information

CHAPTER 34 ASBESTOS. Where is it Found? 34 ASBESTOS. What is Asbestos?

CHAPTER 34 ASBESTOS. Where is it Found? 34 ASBESTOS. What is Asbestos? CHAPTER 34 ASBESTOS 34 ASBESTOS This chapter provides some brief information about asbestos in construction. If you encounter asbestos on the job, you will need more information. Here are the two main

More information

PIER 26 and 28 BULKHEAD LIMITED ASBESTOS and LEAD SURVEY NTE Project No.: NT-3278

PIER 26 and 28 BULKHEAD LIMITED ASBESTOS and LEAD SURVEY NTE Project No.: NT-3278 PIER 26 and 28 BULKHEAD LIMITED ASBESTOS and LEAD SURVEY NTE Project No.: NT-3278 PREPARED FOR: Mr. Roberto Aguirre City of San Francisco DPW, SAR, BCM 1680 Mission Street San Francisco, California PREPARED

More information

Asbestos Inventory and Condition Assessment

Asbestos Inventory and Condition Assessment Prepared for: School District 85 - Vancouver Island North PO Box 9 Port Hardy, British Columbia VN 2P Asbestos Inventory and Condition Assessment NWest Project Number: 315 V.1. Prepared by: 21-415 Gorge

More information

ST. LUKE CATHOLIC ELEMENTARY SCHOOL

ST. LUKE CATHOLIC ELEMENTARY SCHOOL ST. LUKE CATHOLIC ELEMENTARY SCHOOL Final 2017 ACM Re-Assessment Report Project Location: 345 Albright Road Hamilton, ON Prepared for: Hamilton Wentworth Catholic District School Board 57 Stuart Street

More information

What is Asbestos? Asbestos was also used in household items, such as: oven gloves ironing board pads simmer mats for stoves fire blankets.

What is Asbestos? Asbestos was also used in household items, such as: oven gloves ironing board pads simmer mats for stoves fire blankets. All About Asbestos Read this booklet to learn more about: identifying asbestos-containing material in your home the health risks of asbestos what you can do about asbestos. What is Asbestos? Asbestos is

More information

TEXAS CONSULTING SERVICES PO Box 9910 * Midland, Texas Phone: (432) * Fax: (432)

TEXAS CONSULTING SERVICES PO Box 9910 * Midland, Texas Phone: (432) * Fax: (432) TEXAS CONSULTING SERVICES PO Box 9910 * Midland, Texas 79708 Phone: (432) 687-5455 * Fax: (432) 687-5456 Email: Txcs65@yahoo.com May 28, 2015 City of Odessa Community Development PO Box 4398 Odessa, Texas

More information

US-29 (E. Cherokee St.) Bridge over I-85 (Exit 106) Cherokee County, South Carolina Asbestos and Lead-Based Paint Survey Report

US-29 (E. Cherokee St.) Bridge over I-85 (Exit 106) Cherokee County, South Carolina Asbestos and Lead-Based Paint Survey Report US-29 (E. Cherokee St.) Bridge over I-85 (Exit 106) Cherokee County, South Carolina Asbestos and Lead-Based Paint Survey Report ARM Project #16-314-15 March 8, 2017 Prepared For: HDR-ICA 1122 Lady Street,

More information

Asbestos Survey Proposed Roosevelt Development Roosevelt Way NE Seattle, King County, Washington

Asbestos Survey Proposed Roosevelt Development Roosevelt Way NE Seattle, King County, Washington Asbestos Survey Proposed Roosevelt Development 6814-6820 Roosevelt Way NE Seattle, King County, Washington June 19, 2015 Terracon Project No. 81157083 Prepared for: Seattle, Washington Prepared by: Terracon

More information

Asbestos/Lead Paint Survey

Asbestos/Lead Paint Survey Asbestos/ Survey At: Camp Lejeune Bldg 1810 Repair and Reconfigure Warehouse Prepared for: The Walker Group Architecture Inc. PO Box 541 New Bern, NC 28563 PEI Project No.: Walker Group Project No.: 5120-17-0002-2AL

More information

APPENDIX I. DST Hazardous Material Assessment. G3 Terminal Vancouver Port Metro Vancouver Project Permit Application APPENDIX I

APPENDIX I. DST Hazardous Material Assessment. G3 Terminal Vancouver Port Metro Vancouver Project Permit Application APPENDIX I APPENDIX I DST Hazardous Material Assessment APPENDIX I G3 Terminal Vancouver Port Metro Vancouver Project Permit Application DST Consulting Engineers Inc. Unit B 4125 McConnell Drive Burnaby, British

More information

REPORT. Asbestos-Containing Building Materials Assessment Report - Nutana Lawn Bowling Storage Garage CITY OF SASKATOON.

REPORT. Asbestos-Containing Building Materials Assessment Report - Nutana Lawn Bowling Storage Garage CITY OF SASKATOON. CITY OF SASKATOON Asbestos-Containing Building Materials Assessment Report - Nutana Lawn Bowling Storage Garage REPORT Submitted to: The City of Saskatoon 1101 Avenue P North Saskatoon, SK S7L 7K6 Report

More information