RBT Cable for Industrial machinery

Size: px
Start display at page:

Download "RBT Cable for Industrial machinery"

Transcription

1 PRK0-007 RBT Cable for Industrial machinery < shielding> <Special wound conductor > Engineering Dept. Electronic Wires & Cables Production Div. Hitachi Cable, Ltd.

2 This data is lined up our cable for industrial machinery. << Table Contents >> N o Use Rating voltage cond. Size P/N Page The feature HITACHI RBT cables Flexure part 0 pairs 0 cond. 0 pairs 0 cond mm 0.0.mm cond. 0.5mm RBT -V(SB) RBT -V RBT -V(SB) RBT -V pairs 0.5.5mm 6 Core identification 7 Expectation flex life 8 Current carrying capacity The feature HITACHI RBT for high flexure part Conductor Special wound conductor or stranding 0.08mm copper wire Lead free st PVC is standard* Excellent durability against abrasion. (Spiral wrapped by copper wire with staple fiber.) Prevent the abrasion bending. *Heat resistant and oil resistant PVC, Polyurethane, and Fluonlex(50rated st fluoro-ruber) are available.

3 60V rating cable for signal transmission RBT -V(SB) RBT -V for extra high flexure part RBT -V Rating60 Hitachi SpecificationSP-9B, SP-9B for shielding type SP-9B, SP-9B for non-shielding type Size variation Conductor Size Stranding (mm ) (/mm) Dia. Ins. dia.. Max.cond. resistance (/km) / / / / Special wound cond. consist copper Drain wire St PVC (black) Overall Dia. Multi pair with shielding type/(approx. mass) unitmm(kg/km) Size 0.4mm 0.mm 0.mm 0.56mm pairs 4 (45) 7. (60) 8. (80).5 (85) 7 (55) 7.5 (70) 8.7 (95).0 (0) 4 7. (60) 8.0 (80) 9.4 (5) 4.5 (85) (70) 8.8 (00) 0.5 (0) 0 (45) 6 8. (80) 9.5 (5).0 (55) 7.5 (40) (05).0 (40).0 (00).0 (555) (0).0 (70) 4.0 (5).0 (665) 0.5 (0).5 (85) 4.5 (65) 4.0 (750) 6.0 (65).5 (0) 0 (0) 0 (960) 0.0 (95) 5.0 (80) 8.0 (45) 9.0 (90) Note Unit length00mstock item Current carrying capacitypage 8 see table. Non-shielding type is available Overall Dia. Multi core with shielding type/(approx. mass) unitmm(kg/km) Size 0.4mm 0.mm 0.mm 0.56mm cond. 4.9 (9) 5. (6) 5.9 (45) 8. (95) 5. () 5.5 (4) (55) 8.8 (0) (7) 5.9 (48) 6 (65) 9.5 (50) (4) (55) 7. (75) 0.5 (80) 6 0 (47) 7 (65) 7.6 (85).5 (0) 8 7 (60) 7.5 (80) 8.8 (0).5 (75) (65) 7.8 (90) 9. (5) 4.0 (5) 7. (75) 8.0 (00) 9.5 (40) 4.5 (70) (90) 9.0 (5) 0.5 (70) 0 (470) (05) 9.8 (45).0 (0) 8.5 (595) Note Unit length00mstock item Current carrying capacitypage 8 see table. Non-shielding type is available

4 60V rating cable for signal transmission RBT -V(SB) RBT -V for flexure part RBT -V Rating60 Hitachi SpecificationSP-9B, SP-9B for multi pair type SP-94B, SP-94B for multi core type Size variation Conductor Size Stranding (mm ) (/mm) Dia. Ins. dia.. Max.cond. resistance (/km) 0. 40/ / Tinned annealed copper (if required) St PVC (black) Overall Dia. Multi pair with and without shielding type/(approx. mass) unitmm(kg/km) Type Shielding type Non-shielding type Size 0.mm 0.mm 0.mm 0.mm pairs 5.9 (40) (47) 5. (0) 5.7 (6) (46) 6 (60) 5.5 (5) 0 (44) 4 5 (55) 7.0 (70) 5.9 (4) 4 (55) (65) 7.5 (80) 4 (50) 9 (65) (75) 8.0 (90) 8 (60) 7.4 (75) (95) 9. (0) 7.8 (75) 8.7 (00) 0 9. (0) 0.0 (5) 8.6 (90) 9.4 (0) 9.4 (0) 0.5 (50) 8.8 (00) 9.7 (5) (45).5 (95) 9.7 (0).0 (65) 0.5 (80).5 (0).0 (55).0 (0) Note Unit length00mstock item Current carrying capacitypage 8 see table. Overall Dia. Multi core with and without shielding type/(approx. mass) unitmm(kg/km) Type Shielding type Non-shielding type Size 0.mm 0.mm 0.mm 0.mm cond. 4.6 (5) 4.8 (9) 4.0 (8) 4. () 4.7 (8) 5.0 () 4. () 4.4 (5) () 5. (9) 4.4 (4) 4.7 (0) 5 5. (7) 5.6 (44) 4.7 (8) 5.0 (5) (4) 5.9 (50) 4.9 () 5. (40) 8 (55) 5 (65) 5.5 (40) 5.9 (55) 0 4 (60) 9 (75) 5.8 (46) (60) 5 (65) 7.0 (80) 5.9 (55) 4 (70) 6 7. (80) 7.6 (00) 5 (65) 7.0 (85) (95) 8. (0) 7.0 (80) 7.7 (05) Note Unit length00m Current carrying capacitypage 8 see table.

5 600V rating cable for power supply RBT -V(SB) RBT -V for flexure part RBT -V Rating Hitachi SpecificationSP-94B for shielding type SP-94B for non-shielding type Size variation Conductor Size Stranding (mm ) (/mm) Dia. Ins. dia.. Max.cond. resistance (/km) 0.5 7/4/ // /6/ /57/ Tinned annealed copper (if required) St PVC (black) Overall Dia. Multi core with shielding type/(approx. mass) unitmm(kg/km) Size 0.5mm 0.75mm.5mm mm cond 5 (50) 9 (60) 7.7 (80) 8.8 (05) 8 (60) 7. (75) 8. (00) 9. (5) 4 7. (75) 7.9 (90) 9.0 (5) 0.5 (65) (85) 8.7 (0) 9.8 (45).0 (95) (00) 9. (5) 0.5 (70).0 (5) (0).0 (60).5 (5) 4.5 (0) (45).5 (90).5 (65) 5.0 (65).0 (65).0 (0).5 (00) 5.5 (45) 6.0 (0).0 (65) 5.5 (85) 7.5 (550) 0.5 (50) 4.5 (5) 7.5 (485) 9.5 (685) Note Unit length00mstock item Current carrying capacitypage 8 see table. Overall Dia. Multi core without shielding type/(approx. mass) unitmm(kg/km) Size 0.5mm 0.75mm.5mm mm cond. 5.9 (9) (47) 7. (65) 8.0 (85) (47) 7 (60) 7.6 (85) 8.7 (5) 4 7 (60) 7. (75) 8. (05) 9.5 (45) 5 7. (70) 7.9 (90) 9. (0) 0.5 (75) (80) 8.7 (05) 9.9 (50).5 (0) 8 9. (0) 0.0 (40).0 (00).5 (80) (5).0 (60).5 (5) 4.5 (5) 0.5 (45).0 (85).0 (70) 5.0 (85) 6.5 (85).5 (40) 4.5 (55) 7.0 (505) 0.5 (5) 4.0 (95) 5 (45) 8.5 (60) Note Unit length00m Current carrying capacitypage 8 see table.

6 600V rating cable for power supply RBT -V(SB) RBT -V for flexure part RBT -V Rating Hitachi SpecificationSP-9B for shielding type SP-9B for non-shielding type Size variation Conductor Size Stranding (mm ) (/mm) Dia. Ins. dia.. Max.cond. resistance (/km) 0.5 7/4/ // /6/ Tinned annealed copper (if required) St PVC (black) Overall Dia. Multi pair with shielding type/(approx. mass) unitmm(kg/km) Size 0.5mm 0.75mm.5mm pairs 9. (95) 0.5 (5).0 (55) 9.8 (5).0 (40).5 (95) 4.0 (5).0 (70).5 (5) 5.0 (65).0 (05) 5.0 (90) 6.0 (90) 4.5 (45) 5 (40) (50) 5 (5) 9.5 (470) 0 5 (90) 8.0 (85).0 (550) 7.0 (45) 9.0 (40).0 (65) (45).0 (550) 5.0 (795) 0.0 (55) 4.0 (675) 7.0 (980) Note Unit length00m Current carrying capacitypage 8 see table. Overall Dia. Multi pair without shielding type/(approx. mass) unitmm(kg/km) Size 0.5mm 0.75mm.5mm pairs 8.7 (75) 9.5 (95).0 (0) 9. (95) 0.5 (5).0 (70) (5).0 (45).0 (0) 5.0 (5).5 (80) 4.5 (60) 6.5 (65).5 (0) 0 (05) (0) 0 (80) 8.5 (40) (60) 7.5 (40).0 (495) 0 (90) 8.0 (85).0 (565) (75) 0.0 (495) 4.0 (70) (470).0 (65) 7.0 (90) Note Unit length00m Current carrying capacitypage 8 see table.

7 Core identification (Color code) << Multi pair Type >> Pairs Pairs 4Pairs 5Pairs 6Pairs 8Pairs 0Pairs Pairs 6Pairs 0Pairs Table Color code multi pair type. pairs 46pairs 70pairs 5pairs 60pairs pair st.cond. nd.cond. st.cond. nd.cond. st.cond. nd.cond. st.cond. nd.cond. st.cond. nd.cond. Black Brown Black Brown Black Brown Black Brown Black Brown Black Red Black Red Black Red Black Red Black Red Brown Red Black Orange Black Orange Black Orange Black Orange 4 Brown Red Black Yellow Black Yellow Black Yellow 5 Brown Orange Brown Red Black Green Black Green 6 Red Orange Brown Orange Brown Red Black Blue 7 Brown Yellow Brown Orange Brown Red 8 Red Orange Brown Yellow Brown Orange 9 Red Yellow Brown Green Brown Yellow 0 Orange Yellow Red Orange Brown Green Red Yellow Brown Blue Red Green Red Orange Orange Yellow Red Yellow 4 Orange Green Red Green 5 Yellow Green Red Blue 6 Orange Yellow 7 Orange Green 8 Orange Blue 9 Yellow Green 0 Yellow Blue << Multi core Type >> Re Re Br Bl Br Re Or Br Bl Re Ye Br Or Re Bl cores cores 4cores 5cores 6cores 8cores 0cores Vi Br Ye Or Bl Re Or Ye Br Or Ye Re Br Or Ye Re Br Re Re Or Ye Re Br Re Re Re Re cores 6cores 0cores Note:Black, Re:Red, Br:Brown, Bl:Blue, Or:Orange, Ye:Yellow, Vi:Violet, Gray:.

8 Expectation flex life () Foreword NASA has metal fatigue experiment formula which is relationship between bending radius and stress strain. We developed way to the expecting the flex life cables by our bending test data and metal fatigue experiment formula NASA. () Expectation curve flex(bending) life <<Formula>> d Stress strain R t D () Example Following table is examples specimens. Descreption Bending radius* Stress strain RBT -V(SB) 6P0.mm RBT -V(SB) 6P0.mm d: Conductor diameter R: Bending radius t: Sheath thickness + shielding thickness + bind tape thickness D: Insulation diameter Expected flex life 90bending U-bending 57mm mm Approx Approx. 0 7 Bending radius is 6 times sheath diameter. (Our recommended condition) Bending Radius Specimen Stroke Bending radius W Fig. ±90 bending Weight Fig. U-bending

9 Current carrying capacity The current carrying capacities are given by following tables. The following data is conditioned on single cable wiring in free air at ambient temperature 40degree C. pair Table Current carrying capacity RBT -V cable. Current carrying capacity core 0.4mm 0.mm 0.mm 0.56mm pair Table Current carrying capacity RBT -V cable. Current carrying capacity core 0.mm 0.mm 0.5mm 0.75mm.5mm mm Note; If many cables are bundled, current carrying capacity multiplied by adjustable factor;f as following table. bundled cables Adjustable factor ; Note; If the ambient temperature is not 40degree C, current carrying capacity multiplied by adjustable factor;t as following table. Ambient temperature() Adjustable factor ; T

Industrial Cable for Factory Automation

Industrial Cable for Factory Automation Industrial Cable for Factory Automation Line up Multi core & multi pair cables for high flexure part. Heat bonded flat cables for high flexure part. Multi core PVC cables for fixed part. Large size PVC

More information

SafeX110 Single Core Flexible Tinned Copper Cable

SafeX110 Single Core Flexible Tinned Copper Cable LSZH 110 C Flexible SafeX110 Single Core Flexible Tinned Copper Cable Application: Wiring of switchboards, control, general wiring, instrumentation and communication systems. Used where low smoke, zero

More information

Type 1 Machine Cable. Oxygen free tinned annealed copper wire interwoven with high tensile poly-yarn

Type 1 Machine Cable. Oxygen free tinned annealed copper wire interwoven with high tensile poly-yarn Mining Cable Type 1 Machine Cable Application: Typically used for interconnection of control boxes or motors on non-mobile or fixed apparatus. Used when exposure to heat is not an issue and where added

More information

Data sheet chainflex CF887

Data sheet chainflex CF887 1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Filling: Plastic yarns 4. Core insulation: Mechanically high-quality, especially low-capacitance

More information

Available in 0.75 to 16.0 sq mm. Red, Yellow, Blue, Black, White, Gray and Green (for earthing) Specification IS 694:1990

Available in 0.75 to 16.0 sq mm. Red, Yellow, Blue, Black, White, Gray and Green (for earthing) Specification IS 694:1990 Application These cables are used for wiring domestic and coercial buildings. The multi strand flexible conductors make it ideal for concealed wiring. These cables are ideal for wiring in residential and

More information

SPECIFICATION FOR THHN/THWN-2/THW/THWN/TW ARROW ROUTE, FONTANA CA

SPECIFICATION FOR THHN/THWN-2/THW/THWN/TW ARROW ROUTE, FONTANA CA SPECIFICATION FOR THHN/THWN-2/THW/THWN/TW THHN/THWN-2/THW/THWN/TW Listed E-492385 / E-472248 APPLICATIONS THHN/THWN-2 building wire is primarily used for general purpose applications in conduit and cable

More information

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable. Spec. No. GO 5821-4361Rev.2 Issued date : July 13, 2005 Revised 1 date : April 29, 2015 Revised 2 date : February 19, 2016 Specification FOR 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated

More information

Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant PUR sheath

Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant PUR sheath Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant PUR sheath - Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant

More information

Separator, suitable tape between the braid and outer sheath

Separator, suitable tape between the braid and outer sheath Picture is for information only. Applicable standards: NEK TS 606 Code S1/S5, IEC 60092-376- Design guidelines IEC 60228 conductor IEC 60092-351 Insulating material, IEC 60092-359 Sheathing materials IEC

More information

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category.

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category. Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category. Superastic Flex Extra sliding for extra easy installation. Superastic Flex cables are ideal for those who want to save installation

More information

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed] [6.35/11kV Copper XLPE Three-Core HDPE Sheathed] APPLICATION Mostly used as feeder electric cable for power distribution network such as power supply station, substation, switching system etc. They are

More information

H-FLEX CABLES 10/2017

H-FLEX CABLES 10/2017 10/2017 H-FLEX CABLES CONTENTS H-FLEX PWR PUR 0,6/1kV...2 H-FLEX PWR C-PUR 0,6/1kV...6 H-FLEX CTL PUR 250V...10 H-FLEX CTL C-PUR 250V...12 H-FLEX INS PUR 250V...14 H-FLEX INS C-PUR 250V...16 TECHNICAL

More information

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified - Screened power and control cable for versatile use in power chains with UL/cUL AWM certification.

More information

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath 0.6/1 kv LOW VOLTAGE CONTROL CABLES PVC OR XLPE INSULATED, PVC SHEATHED AS PER IEC 60502-1 Conductors Conductors shall be Circular Stranded, Class 2 as per IEC 60228, BS EN 60228. Upon request, Solid Circular

More information

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified - Screened power and control cable for versatile use in power chains with UL/cUL AWM certification.

More information

Construction guideline

Construction guideline 1/6 1) SUMMARY OF ABBREVIATIONS FOR CABLE CONSTRUCTION ELEMENTS MSR - : EUPEN code for INSTRUMENTATION CABLES JE - : cable for INDUSTRIAL ELECTRONICS RD - : cable for CONTROL SYSTEMS INSULATION MATERIALS:

More information

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths Datasheet ENGLISH Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths High temperature, rugged, flexible Pt100 probe Suitable

More information

Caledonian Cables Ltd

Caledonian Cables Ltd Caledonian Motor Connection Cable Caledonian Cables Ltd s 1 Addison Addison Motor Connection Cable Company Profile Caledonian. established in 1978.offers one of the most complete lines of fiber and copper

More information

Specifications of. Single Armored Optical Fiber Cable

Specifications of. Single Armored Optical Fiber Cable SPEC. NO A15022701 Sheet no.1 of 7 Date: 15-02-27 Specifications of Single Armored Optical Fiber Cable (GYFTS) 1. General SPEC.NO A15022701 Sheet No.2 of 7 1.1 This specification covers the requirements

More information

WHITE PAPER Flex Life vs Flexibility

WHITE PAPER Flex Life vs Flexibility WHITE PAPER Flex Life vs Flexibility The design criteria for both flex life and flexibility is the same but the properties and application of the elements can be vastly different. The design elements are

More information

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code Datasheet Platinum Resistance Pt100 Tubular Ceramic Insert Elements with tail wires 2 or 4 wire with choice of Teflon or nickel/glassfibre insulated tail wires up to 450mm long ENGLISH 237-1635 237-1641

More information

Flexible Cables for Cranes and other industrial applications

Flexible Cables for Cranes and other industrial applications Flexible Cables for Cranes and other industrial applications Fujikura Ltd. Version 3 Update Aug.13, 2014 1 Cable selection depending on the application Application 2/3PNCT-B G-/3PNCT-B 2/3PNCT-H 2/3PNCT-H-U

More information

Data sheet chainflex CFSPECIAL.182

Data sheet chainflex CFSPECIAL.182 Ethernet (CAT5/CAT5e/GigE/PoE) Profinet (Type C) 1 / 8 Cable structure Conductor Core insulation Stranded conductor in especially bending-resistant version consisting of bare copper wires (following DIN

More information

Single core conductor BETAtherm 145

Single core conductor BETAtherm 145 Internet: www.synflex.de Single core conductor BETAtherm 145 Description BETAtherm 145 is a flexible low-voltage cable with UL recognition consisting of a tinned copper stranded wire and insulated with

More information

Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves

Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves ENGLISH Datasheet Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves Pt100 Autoclave & steriliser drain temperature probe For use to monitor the fluid

More information

Instrumentation Cables

Instrumentation Cables Instrumentation Cables Product Catalogue Factories and Regional Offices Tai Sin Electric Limited 24 Gul Crescent Jurong Town Singapore 62953 Tel: (+65) 6672 9292 Fax: (+65) 686 4084 E-Mail: sales@taisin.com.sg

More information

6A-38 Jumper Wire (IJP) (Rank A)

6A-38 Jumper Wire (IJP) (Rank A) DISCLAIMER: This translation may be used for reference purpose only. This English version is not an official translation of the original Japanese document. In cases where any differences occur between

More information

SPECIFICATION FOR FRLS POWER CABLES

SPECIFICATION FOR FRLS POWER CABLES SPECIFICATION FOR FRLS POWER CABLES 1.0 SCOPE This specification cover the technical requirements of design, manufacture, testing and delivery to site of Power Cables of 1100V grade with FRLS PVC Sheathed,

More information

ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead

ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead (Image shows 4 wire) Pt1000 element to IEC 751 Class B 2 wire configuration Temperature range -50 C to + 200 C Pt1000

More information

26/35kV Copper XLPE Insulation Electric Cable

26/35kV Copper XLPE Insulation Electric Cable 26/35kV Copper XLPE Insulation Electric Cable Specifications 1.1~35kv XLPE insulated power cable 2.Standard: IEC,VDE,BS,UL,AS/NZS Black PVC sheath XLPE insulated armored copper power cable YJV22 YJV32

More information

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR Category 6 Plus Plenum Category 6 Plus Plenum has a cross web design for maximum pair separation. It features sequential footage markings that count down to zero feet -- removing the guess work concerning

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. AFC Cable Systems, Inc. Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519.13 METAL CLAD CABLE-MC

More information

YKY, YKY-żo 0,6/1kV PN-93/E-90401, PN-HD-603 S1, IEC

YKY, YKY-żo 0,6/1kV PN-93/E-90401, PN-HD-603 S1, IEC PVC insulated and PVC sheathed power cable CONSTRUCTION Conductors: annealed copper solid class 1(RE), circular or circular compacted stranded conductor class 2 (RM, RMC) or stranded sector shaped conductor

More information

M-FLEX CONTROL CABLES

M-FLEX CONTROL CABLES M-FEX COTRO CABES Flexible, workable and environmentally resistant. FOR IDUSTRY Your reliable partner for integrated industrial cable solutions. Prysmian Group is world leading in the development and production

More information

600 VOLT 600V, 3 CONDUCTOR (WITH GROUND), FR-EPR OR FR-XLPE INSULATION, PVC JACKET SPECIFICATIONS (FLAME RETARDANT POWER CABLE) (UL TYPE TC-ER) TYPE C3 SPEC 70.0100 PROJECT 196116 REFERENCE: LATEST EDITIONS

More information

PRODUCT INFORMATION ÖLFLEX CRANE. Info Suitable for outdoor use Integrated supporting element Also suitable for power chains and cable trolley systems

PRODUCT INFORMATION ÖLFLEX CRANE. Info Suitable for outdoor use Integrated supporting element Also suitable for power chains and cable trolley systems Highly flexible and weather-proof rubber cables with support element - flexible cable, flame retardant for outdor use and crane applications/conveyour technology, power and control rubber cable, U 0 /U:300/500V

More information

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal) ENGLISH Datasheet Platinum Resistance Pt100 Wire-Wound Detector Elements Pt100 platinum resistance thermometer elements in a choice of sizes single & dual element Pt100 elements to IEC 60751 Class A or

More information

Highly flexible control cable with PVC core insulation and PVC sheath - certified for North America

Highly flexible control cable with PVC core insulation and PVC sheath - certified for North America Highly flexible control cable with PVC core insulation and PVC sheath - certified for North America - Power and control cable for versatile use in power chains with UL/cUL AWM certification Info Basic

More information

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm) ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm) Pt100 Elements, Thin Film (100 Ohm) Pt100 elements to IEC751 Class A,

More information

Electric cables. CRANES APPENDIX

Electric cables. CRANES APPENDIX Electric cables. CRANES APPENDIX Electric cables for mobile connections. Aristoncavi spa reserve the right to modify the data in this catalogue without notice. 06/0 Copyright Drawings and technical descriptions

More information

Wires & Cables for Space Applications

Wires & Cables for Space Applications Wires & Cables for Space Applications Aerospace Business Unit Draka Fileca S.A.S. is part of the Prysmian Group, the world leader in the cable systems industry, listed on the Milan Stock Exchange. With

More information

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead Datasheet Platinum Resistance Pt100 Sheathed Thin Film Strip Sensor 2 wire sensor sheathed in a thin stainless steel shim body ideal for surface measurement ENGLISH Sheathed Pt100 element in a thin, flat

More information

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0 REVISION NO. 0 NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0 PAGE NO. 1 OF 24 DATE OF ISSUE (MONTH/YEAR) TOTAL NO. OF PAGES (Including cover

More information

MANUFACTURER'S QUALITY ASSURANCE PLAN (QAP - Instrumentation cables)

MANUFACTURER'S QUALITY ASSURANCE PLAN (QAP - Instrumentation cables) POLARIS CABLES & WIRES PVT. LTD. (An IS & ISO 9001 :2000 Certified Company) Plant : Plot 35, Genesis Indl Complex, Kolgaon, PALGHAR, Dist :Thane, Maharashtra. MANUFACTURER'S QUALITY ASSURANCE PLAN (QAP

More information

Cables for Drag Chains

Cables for Drag Chains HELUKABEL Products are available from MARYLAND METRICS P.O. Box 21 Owings Mills, MD 211 USA web: http://mdmetric.com ph: (4)35-3130 (00)3-30 fx: (4)35-32 (00)72-9329 email: sales@mdmetric.com RFQ form:

More information

SERVICE ENTRANCES. OPPD S Electrical Service Designer (ESD) shall designate the Point Of Entrance.

SERVICE ENTRANCES. OPPD S Electrical Service Designer (ESD) shall designate the Point Of Entrance. SERVICE ENTRANCES 3.01 POINT OF ENTRANCE General Service The customer, or the customer s electrician, should provide OPPD with a site plan, load schedule, and voltage requirements when requesting service.

More information

Pt100 (100 0 C) to IEC 751, Class B, 4 wire 3.0, 4.0, 4.5 or 6.0mm diameter 316 stainless steel sheath.

Pt100 (100 0 C) to IEC 751, Class B, 4 wire 3.0, 4.0, 4.5 or 6.0mm diameter 316 stainless steel sheath. Datasheet Platinum Resistance Thermometer Pt100 Industrial Sensor Probe, Class B Available in 3.0, 4.0, 4.5 or 6.0mm diameter x Various probe lengths ENGLISH Multipurpose Pt100 Probe to IEC751 Class B,

More information

Compact Module. Enhanced Category 5 FTP Cabling System

Compact Module. Enhanced Category 5 FTP Cabling System Compact Module Enhanced Category 5 performance Suitable for Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro modules and blanks Individually QA tested Easy to use

More information

Connecting the world through technology and quality

Connecting the world through technology and quality Connecting the world through technology and quality G. K. Enterprises (P) Ltd. An ISO 9 : 28 Certified Company Unit I - C-, Sector 58, Noida -23 (U.P.), (India) Unit II - C - 6, Sector 58, Noida -23 (U.P.),

More information

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072. 37-105VFD MMV-VFD Power Cable Three : kv - 15kV 133% Level Rated 90 C s (3) Soft annealed flexible stranded tinned copper per IEEE 150 Table 11. Extruded thermosetting 90 C Ethylene Propylene Rubber (EPR),

More information

Manhattan Thermocouple Cable

Manhattan Thermocouple Cable Manhattan Thermocouple Cable Temperature Measurement and Control The measurement of temperature is one of the most vital functions in the control of manufacturing and processing operations. As demands

More information

Comparison of BS 5308, PAS 5308 and BS EN

Comparison of BS 5308, PAS 5308 and BS EN Comparison of BS 5308, PAS 5308 and BS EN 50288 Scope BS 5308 Part 1: 1986- Instrumentation Cables Part 1. Specification for Polyethylene Insulated Cables (withdraw, superseded by BS EN 50288-7) BS 5308

More information

Reeling Cables www.sab-worldwide.com CONTENT page The Company....................................................................................................... 2 DR 717 P Highflex 300/500 V.........................................................................................

More information

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths ENGLISH Duplex PRT s with two independent PT100 detectors inside tip of probe. This

More information

Kaf-Tech Product Specification

Kaf-Tech Product Specification Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519.13 METAL CLAD CABLE-LUMINARY CABLE

More information

Cables for robots www.sab-worldwide.com CONTENT page < The company............................................................................... < Clientele / supplier numbers........................................................................

More information

SERV-RITE Wire and Cable

SERV-RITE Wire and Cable SERV-RITE SERVTEX Insulated Extension Wire Series 155 STOCKED FOR SAME DAY SHIPMENT K16/5/155 K16/7/155 E N J S K T 2-3. 20 16 14 20 stranded (7/28) 16 stranded (7/24) 14 stranded (7/22) 4. Type/Tolerance

More information

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with DIN B Head

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with DIN B Head ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with DIN B Head With stainless steel plug (no thread) Pt100 probe with DIN B terminal head Class B, 4 wire connection Various

More information

CONSULTATIONS TECHNICAL GUIDELINE. HVDC extruded cable

CONSULTATIONS TECHNICAL GUIDELINE. HVDC extruded cable UNIT, BU1SNESS AREA OUR REFERENCE TR14-02-2E DATE 2018-01-24 CONSULTATIONS TECHNICAL GUIDELINE EDITION 1 APPROVED HVDC extruded cable This technical guideline describes the basic design and construction

More information

Title Cables for Railway Signalling Applications - Traction Return Bonding and Track Connection Cables

Title Cables for Railway Signalling Applications - Traction Return Bonding and Track Connection Cables Discipline Engineering Standard NSW Category Signalling Title Cables for Railway Signalling Applications - Traction Return Bonding and Track Connection Cables Reference Number SPS 49 - (RIC Standard: SC

More information

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE TI 20 PVC TI 20 INSULATED TELEPHONE WIRE Standard: Nominal voltage: Temperature range - fixed laying: Cable Structure: Application: Packing: 2x0,5 0,4 2,6 3,6 7,2 2x0,6 0,4 2,8 5,2 9,1 2x0,8 0,4 3,2 9,2

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS PAGODA CABLES PVT. LTD. 1/58, STREET NO: 3, VISHWAS NAGAR, SHAHDARA, DELHI 110 032. (INDIA) TEL/FAX : 91-11-22392801, 22385391. Email : pagoda @del2.vsnl.net.in CONTENTS: 1. 2.

More information

Article-No. Type. All dimensions in mm. Subject to technical changes. Other dimensions, reel lengths or colours available on request.

Article-No. Type. All dimensions in mm. Subject to technical changes. Other dimensions, reel lengths or colours available on request. 4.4 Installation Devices HelaTape HellermannTyton offers a wide range of PVC and rubber tapes for sealing, insulation and bundling of cable and conduits. PVC based tapes are designed for low voltage applications

More information

Cables de Comunicaciones Zaragoza. CW1601 Approval application.

Cables de Comunicaciones Zaragoza. CW1601 Approval application. 1. GENERAL INFORMATION 1.1 LIST OF CONTENTS Cables de Comunicaciones Zaragoza. CW1601 Approval application. 1. General Information 1.1 List of Contents 1.2 Contractors Name 1.3 Test report 1.4 Product

More information

Platinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing

Platinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing Datasheet ENGLISH Platinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing Pt100 Patch Sensor (100 Ω Ohms @ 0

More information

Halogen-free data transmission cable with colour code acc. to DIN resistant to a wide range of chemical media

Halogen-free data transmission cable with colour code acc. to DIN resistant to a wide range of chemical media Halogen-free data transmission cable with colour code acc. to DIN 47100 - resistant to a wide range of chemical media :Screened low-freq data cable Twisted pairs Biopetroleum/ cleaner/ hotwater/ hydraulic

More information

MATERIAL STANDARD FOR CABLES AND WIRES

MATERIAL STANDARD FOR CABLES AND WIRES MATERIAL STANDARD FOR CABLES AND WIRES CONTENTS : PAGE No. 1. SCOPE... 2 2. SERVICE CONDITIONS... 2 3. REFERENCES AND STANDARDS... 2 4. UNITS... 3 5. CABLE DESIGN AND CONSTRUCTION... 3 5.1 Applicable Cable

More information

JAMES MONROE. WIRE & CABLE CORPORATION ETT Traveling Cable Hoistway Cable Compensating Cable Stationary Communications Cable ELEVATOR CABLES

JAMES MONROE. WIRE & CABLE CORPORATION ETT Traveling Cable Hoistway Cable Compensating Cable Stationary Communications Cable ELEVATOR CABLES WIRE & CABLE CORPORATION ETT Traveling Cable Hoistway Cable Compensating Cable Stationary Communications Cable ELEVATOR CABLES Elevator Hoistway & Traveling Cables... Designed for high performance and

More information

Platinum Resistance Thermometer Pt100 Precision Probe - High accuracy platinum resistance thermometer probe, 6mm diameter x 250mm

Platinum Resistance Thermometer Pt100 Precision Probe - High accuracy platinum resistance thermometer probe, 6mm diameter x 250mm Datasheet ENGLISH Platinum Resistance Thermometer Pt100 Precision Probe - High accuracy platinum resistance thermometer probe, 6mm diameter x 250mm Precision Pt100 sensor offering high accuracy over the

More information

YF /8" YF /2" YF /4"

YF /8 YF /2 YF /4 Wire Over-Braided Flexible Conduit ( YF-705 ) most suitable for demanding industrial wiring applications. *Galvanized steel helically wound with PVC coating and wire over-braid. *Trade size: 3/8"~2" (square

More information

according to UL AWM 758, Style and based on EN resp. VDE

according to UL AWM 758, Style and based on EN resp. VDE Application ÖLFLEX SERVO FD 798 CP cables are high-flexible, screened, oil-resistant, halogen free, signal (encoder and resolver) cables with an outer sheath of Polyurethane. They are designed for use

More information

PURENET-U (Part No.: U RXX2, U PXX2)

PURENET-U (Part No.: U RXX2, U PXX2) ISSUED: FEB. 3, 2010 PAGE : 1 OF 6 PURENET-U5350-00 (Part No.: U5350-04-RXX2, U5350-04-PXX2) for 4 PAIR UTP CABLES (ENHANCED CATEGORY 5E) ( Ref.: UL 444, ANSI/TIA/EIA-568B.2 & ISO/IEC 11801,IEC 61156-5

More information

CABLEMASTER CABLE GUIDE

CABLEMASTER CABLE GUIDE CABLEMASTER COAXIAL, DATA, TELEPHONE & SPECIAL CABLES CABLE GUIDE REFERENCES: FOXTEL F10231, F30128 OPTUS SAP17874, SAP4868 AS/ACIF S008:2001 N2020 Skandia Pty Ltd Issue: 2.0 Revision: 1 Date of issue:

More information

RG-59, RG-59+2DC, UTP CAT6, SFTP CAT6

RG-59, RG-59+2DC, UTP CAT6, SFTP CAT6 FLAT ELEVATOR CABLE RG59, RG59+2DC, UTP CAT6, SFTP CAT6 COPPER SERIES MAIN FEATURES ASTEL RG59 Lift Monitor cablescopper Series are designed and manufactured to Ultra flexibility demand of CCTV Cameras

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION Sep., 2005 PAGE / 8 Jan. 20, 2007 PRODUCT NAME : STW-F RATING : 55 C, 000V rms No. Revised Date Revised Details Page Report Jan. 20, 2007 Emendation of Specification All - REPORTED BY: APPROVED BY: Q.M.

More information

Energy Chain System Training

Energy Chain System Training Energy Chain System Training 1. Energy Chain Cable Carriers 2. ChainFlex - Continuous Flex Cables 3. Types of Installations 4. Specifying an E-Chain System / Important Design Considerations Energy Chain

More information

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR PART 1 - GENERAL Section 26 05 15 SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR 1.1 Cable shall be 15 kv, shielded, three conductor with ground, stranded copper, with continuously welded and corrugated

More information

150 mm. 1/8 BSPP brass male compression fitting with locknut included

150 mm. 1/8 BSPP brass male compression fitting with locknut included ENGLISH Datasheet Platinum Resistance PT100 Flat Tip Probe 4mm diameter x 150mm long 2 wire with 1 metre flying lead, complete with 1/8 BSP compression fitting & locknut 4mm 25mm 5.5/6mm(max) 150 mm General

More information

NEMA Standards Publication No. WC ICEA Publication No. S

NEMA Standards Publication No. WC ICEA Publication No. S NEMA Standards Publication No. WC 71-1999 ICEA Publication No. S-96-659-1999 Standard for Nonshielded Cables Rated 2001-5000 Volts for use in the Distribution of Electric Energy Published by National Electrical

More information

Copper Cable Company Limited

Copper Cable Company Limited Cables and Wires Copper Cable Company Limited Copper Cable Company is the UK subsidiary of TELE-FONIKA Kable S.A., with offices and a warehouse centrally located in Leicestershire. 2 A major supplier to

More information

Four Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

Four Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable Edition Nº: 9 THE ISRAEL ELECTRIC CORPORATION LTD. Specification No. NPS-76 for Four Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable for Rated Voltage U0/U = 0.6/1.0

More information

ENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting

ENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting ENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting RJT unions (Ring Joint Type) are often referred to as a standard union. The compromise of an O-ring style gasket

More information

Armoured Instrumentation Cables to BS7917

Armoured Instrumentation Cables to BS7917 Armoured Instrumentation Cables to BS1 Fire Resistant, Pairs/Triples - Collectively Screened. Low Smoke Zero Halogen TAC, MGT, EPR, SCRN, ZH, GSWB, SW 0/0V Application Control and instrumentation cable

More information

SECTION ELECTRICAL CABLE. 1. Trench excavation, backfill, and compaction; Section

SECTION ELECTRICAL CABLE. 1. Trench excavation, backfill, and compaction; Section 02735-1 of 5 SECTION 02735 ELECTRICAL CABLE 02735.01 GENERAL A. Description Electrical cable installation shall include, but not necessarily be limited to, furnishing and placing electrical cable as shown

More information

3M Round, Shielded/Jacketed, Disc. Wire Cable 26 AWG Solid, Twisted Pair, PVC/PVC 3560 Series

3M Round, Shielded/Jacketed, Disc. Wire Cable 26 AWG Solid, Twisted Pair, PVC/PVC 3560 Series M Round, Shielded/Jacketed, Disc. Wire Cable 26 AWG Solid, Twisted Pair, PVC/PVC 560 Series Twisted pairs reduce crosstalk for balanced drive applications Dual shielding provides 5 db average shielding

More information

TECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1

TECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1 ANNEXURE TO TENDER NO. PUR42396GM DATED 06 th FEBRUARY 2014 SUPPLY OF 1.1KV GRADE LT POWER CABLES FOR THE PERIOD APRIL 2014 MARCH 2016 TECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1 1.1 SCOPE

More information

*Nominal values are to be used as guidelines only; this is not a product specification and does not indicate minimum or maximum values.

*Nominal values are to be used as guidelines only; this is not a product specification and does not indicate minimum or maximum values. UNITED POLY SYSTEMS C O N D U I T Applications include: Installation: T e l e c o m, E n e r g y, D O T, E t c. E x i s t i n g C o n d u i t, P l o w, D i r e c t B u r i a l, H D D ( H o r i z o n t

More information

ENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument

ENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument Datasheet ENGLISH Platinum Resistance Thermometer Pt100 Outdoor/Cold Store Temperature Sensors IP67 Weatherproof Housing, 4 wire single or dual element, or 4-20mA option Weatherproof IP67 rated wall mounting

More information

Photo: HELUKABEL. Robotic Cables H 1

Photo: HELUKABEL. Robotic Cables H 1 Photo: HELUKABEL Robotic Cables H 1 Robotic Cables With over 30 years of experience with cables and lines, we also have the right solutions for the demands placed on the components to be installed by the

More information

DATA SHEET Single Core 2HR Fire Rated Cable

DATA SHEET Single Core 2HR Fire Rated Cable Features: 2HR Fire Rated 0.6/1kV Insulation Rating 110 o C Continuous Operation AS/NZS 3013 WS52W AS/NZS 5000.1 AS/ACIF S008 RCM Certified Low Smoke Zero Halogen Flame Retardant Flexible Class 6 Conductors

More information

Cables for Railway Signalling Applications General Requirements

Cables for Railway Signalling Applications General Requirements Discipline: Engineering (Signalling) Category: Procedure Cables for Railway Signalling Applications General Requirements ESA-11-01 Applicability ARTC Network Wide Primary Source ESA-02-01 Document Status

More information

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV) EDC3 (5239) P3 Mini-Grid Systems DRAFT TANZANIA STANDARD Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV) TANZANIA BUREAU OF STANDARDS TBS 2017 First Edition 2017 Table of Contents

More information

Engineering Data for Copper and Aluminum Conductor Electrical Cables

Engineering Data for Copper and Aluminum Conductor Electrical Cables 2018 Edition Engineering Data for Copper and Aluminum Conductor Electrical Cables THE OKONITE COMPANY Okonite Cables...A higher Standard! The Okonite Company, 2018 Okonite Cables Table of Contents SECTION

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519 METAL CLAD CABLE - MC-PLUS Neutral

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION 4 PAIR UTP CABLE CAT6 (CATEGORY 6 PLUS) Page 1 of 5 1. SCOPE This specification is based on the specifications of UL 444, ANSI/TIA/EIA-568-B,ISO/IEC 1801, UL 1685(CM) and covers

More information

Tip Jacks. Johnson Components P.O. Box 1732 Waseca, MN Fax:

Tip Jacks. Johnson Components P.O. Box 1732 Waseca, MN Fax: .060" (1.5 mm) Shrouded Tip Jack (Solder or Crimp) 5.060" (1.5 mm) Uninsulated Tip Jack (Solder or Crimp) 5.060 (1.50) Shrouded Tip Jack (Solder or Crimp) 5.060 (1.50) Uninsulated Tip Jack (Solder or Crimp)

More information

SOFC-DA-180KN-192 G652D

SOFC-DA-180KN-192 G652D Description The design of the offered cable has been a typical structure of submarine cables which is prevailing over the world and has been approved for stable performance in submarine cable system. Loose

More information

Qualification Reference: AA/ Cage Code: MIL-C Cables NEMA WC27500 Part Number Builder

Qualification Reference: AA/ Cage Code: MIL-C Cables NEMA WC27500 Part Number Builder Qualification Reference: 15404201.AA/1-20-2015 Cage Code: 67050 MIL-C-27500 Cables NEMA WC27500 Part Number Builder MIL-C-27500 Cables NEMA WC 27500 Part Number Builder MIL-C-27500 (M27500 Cable) MIL Spec

More information

MGO INSULATED THERMOCOUPLES INDEX

MGO INSULATED THERMOCOUPLES INDEX MGO INSULATED THERMOCOUPLES INDEX PAGE General Information... M1 Part Numbering Examples... M4 Thermocouple Elements (MA)... M5 Leadwire Style Thermocouples (MB)... M6 Leadwire Style Thermocouples (MD,

More information

Wire and Cable SPEC 44 Wire and Cable

Wire and Cable SPEC 44 Wire and Cable High-performance wire and cable sulation system for 65 C to Wire and Cable SPEC 44 Wire and Cable Applications Hookup and signal wire and cable used aircraft, avionics, military electronics, satellites,

More information