RBT Cable for Industrial machinery
|
|
- Francis Rodgers
- 5 years ago
- Views:
Transcription
1 PRK0-007 RBT Cable for Industrial machinery < shielding> <Special wound conductor > Engineering Dept. Electronic Wires & Cables Production Div. Hitachi Cable, Ltd.
2 This data is lined up our cable for industrial machinery. << Table Contents >> N o Use Rating voltage cond. Size P/N Page The feature HITACHI RBT cables Flexure part 0 pairs 0 cond. 0 pairs 0 cond mm 0.0.mm cond. 0.5mm RBT -V(SB) RBT -V RBT -V(SB) RBT -V pairs 0.5.5mm 6 Core identification 7 Expectation flex life 8 Current carrying capacity The feature HITACHI RBT for high flexure part Conductor Special wound conductor or stranding 0.08mm copper wire Lead free st PVC is standard* Excellent durability against abrasion. (Spiral wrapped by copper wire with staple fiber.) Prevent the abrasion bending. *Heat resistant and oil resistant PVC, Polyurethane, and Fluonlex(50rated st fluoro-ruber) are available.
3 60V rating cable for signal transmission RBT -V(SB) RBT -V for extra high flexure part RBT -V Rating60 Hitachi SpecificationSP-9B, SP-9B for shielding type SP-9B, SP-9B for non-shielding type Size variation Conductor Size Stranding (mm ) (/mm) Dia. Ins. dia.. Max.cond. resistance (/km) / / / / Special wound cond. consist copper Drain wire St PVC (black) Overall Dia. Multi pair with shielding type/(approx. mass) unitmm(kg/km) Size 0.4mm 0.mm 0.mm 0.56mm pairs 4 (45) 7. (60) 8. (80).5 (85) 7 (55) 7.5 (70) 8.7 (95).0 (0) 4 7. (60) 8.0 (80) 9.4 (5) 4.5 (85) (70) 8.8 (00) 0.5 (0) 0 (45) 6 8. (80) 9.5 (5).0 (55) 7.5 (40) (05).0 (40).0 (00).0 (555) (0).0 (70) 4.0 (5).0 (665) 0.5 (0).5 (85) 4.5 (65) 4.0 (750) 6.0 (65).5 (0) 0 (0) 0 (960) 0.0 (95) 5.0 (80) 8.0 (45) 9.0 (90) Note Unit length00mstock item Current carrying capacitypage 8 see table. Non-shielding type is available Overall Dia. Multi core with shielding type/(approx. mass) unitmm(kg/km) Size 0.4mm 0.mm 0.mm 0.56mm cond. 4.9 (9) 5. (6) 5.9 (45) 8. (95) 5. () 5.5 (4) (55) 8.8 (0) (7) 5.9 (48) 6 (65) 9.5 (50) (4) (55) 7. (75) 0.5 (80) 6 0 (47) 7 (65) 7.6 (85).5 (0) 8 7 (60) 7.5 (80) 8.8 (0).5 (75) (65) 7.8 (90) 9. (5) 4.0 (5) 7. (75) 8.0 (00) 9.5 (40) 4.5 (70) (90) 9.0 (5) 0.5 (70) 0 (470) (05) 9.8 (45).0 (0) 8.5 (595) Note Unit length00mstock item Current carrying capacitypage 8 see table. Non-shielding type is available
4 60V rating cable for signal transmission RBT -V(SB) RBT -V for flexure part RBT -V Rating60 Hitachi SpecificationSP-9B, SP-9B for multi pair type SP-94B, SP-94B for multi core type Size variation Conductor Size Stranding (mm ) (/mm) Dia. Ins. dia.. Max.cond. resistance (/km) 0. 40/ / Tinned annealed copper (if required) St PVC (black) Overall Dia. Multi pair with and without shielding type/(approx. mass) unitmm(kg/km) Type Shielding type Non-shielding type Size 0.mm 0.mm 0.mm 0.mm pairs 5.9 (40) (47) 5. (0) 5.7 (6) (46) 6 (60) 5.5 (5) 0 (44) 4 5 (55) 7.0 (70) 5.9 (4) 4 (55) (65) 7.5 (80) 4 (50) 9 (65) (75) 8.0 (90) 8 (60) 7.4 (75) (95) 9. (0) 7.8 (75) 8.7 (00) 0 9. (0) 0.0 (5) 8.6 (90) 9.4 (0) 9.4 (0) 0.5 (50) 8.8 (00) 9.7 (5) (45).5 (95) 9.7 (0).0 (65) 0.5 (80).5 (0).0 (55).0 (0) Note Unit length00mstock item Current carrying capacitypage 8 see table. Overall Dia. Multi core with and without shielding type/(approx. mass) unitmm(kg/km) Type Shielding type Non-shielding type Size 0.mm 0.mm 0.mm 0.mm cond. 4.6 (5) 4.8 (9) 4.0 (8) 4. () 4.7 (8) 5.0 () 4. () 4.4 (5) () 5. (9) 4.4 (4) 4.7 (0) 5 5. (7) 5.6 (44) 4.7 (8) 5.0 (5) (4) 5.9 (50) 4.9 () 5. (40) 8 (55) 5 (65) 5.5 (40) 5.9 (55) 0 4 (60) 9 (75) 5.8 (46) (60) 5 (65) 7.0 (80) 5.9 (55) 4 (70) 6 7. (80) 7.6 (00) 5 (65) 7.0 (85) (95) 8. (0) 7.0 (80) 7.7 (05) Note Unit length00m Current carrying capacitypage 8 see table.
5 600V rating cable for power supply RBT -V(SB) RBT -V for flexure part RBT -V Rating Hitachi SpecificationSP-94B for shielding type SP-94B for non-shielding type Size variation Conductor Size Stranding (mm ) (/mm) Dia. Ins. dia.. Max.cond. resistance (/km) 0.5 7/4/ // /6/ /57/ Tinned annealed copper (if required) St PVC (black) Overall Dia. Multi core with shielding type/(approx. mass) unitmm(kg/km) Size 0.5mm 0.75mm.5mm mm cond 5 (50) 9 (60) 7.7 (80) 8.8 (05) 8 (60) 7. (75) 8. (00) 9. (5) 4 7. (75) 7.9 (90) 9.0 (5) 0.5 (65) (85) 8.7 (0) 9.8 (45).0 (95) (00) 9. (5) 0.5 (70).0 (5) (0).0 (60).5 (5) 4.5 (0) (45).5 (90).5 (65) 5.0 (65).0 (65).0 (0).5 (00) 5.5 (45) 6.0 (0).0 (65) 5.5 (85) 7.5 (550) 0.5 (50) 4.5 (5) 7.5 (485) 9.5 (685) Note Unit length00mstock item Current carrying capacitypage 8 see table. Overall Dia. Multi core without shielding type/(approx. mass) unitmm(kg/km) Size 0.5mm 0.75mm.5mm mm cond. 5.9 (9) (47) 7. (65) 8.0 (85) (47) 7 (60) 7.6 (85) 8.7 (5) 4 7 (60) 7. (75) 8. (05) 9.5 (45) 5 7. (70) 7.9 (90) 9. (0) 0.5 (75) (80) 8.7 (05) 9.9 (50).5 (0) 8 9. (0) 0.0 (40).0 (00).5 (80) (5).0 (60).5 (5) 4.5 (5) 0.5 (45).0 (85).0 (70) 5.0 (85) 6.5 (85).5 (40) 4.5 (55) 7.0 (505) 0.5 (5) 4.0 (95) 5 (45) 8.5 (60) Note Unit length00m Current carrying capacitypage 8 see table.
6 600V rating cable for power supply RBT -V(SB) RBT -V for flexure part RBT -V Rating Hitachi SpecificationSP-9B for shielding type SP-9B for non-shielding type Size variation Conductor Size Stranding (mm ) (/mm) Dia. Ins. dia.. Max.cond. resistance (/km) 0.5 7/4/ // /6/ Tinned annealed copper (if required) St PVC (black) Overall Dia. Multi pair with shielding type/(approx. mass) unitmm(kg/km) Size 0.5mm 0.75mm.5mm pairs 9. (95) 0.5 (5).0 (55) 9.8 (5).0 (40).5 (95) 4.0 (5).0 (70).5 (5) 5.0 (65).0 (05) 5.0 (90) 6.0 (90) 4.5 (45) 5 (40) (50) 5 (5) 9.5 (470) 0 5 (90) 8.0 (85).0 (550) 7.0 (45) 9.0 (40).0 (65) (45).0 (550) 5.0 (795) 0.0 (55) 4.0 (675) 7.0 (980) Note Unit length00m Current carrying capacitypage 8 see table. Overall Dia. Multi pair without shielding type/(approx. mass) unitmm(kg/km) Size 0.5mm 0.75mm.5mm pairs 8.7 (75) 9.5 (95).0 (0) 9. (95) 0.5 (5).0 (70) (5).0 (45).0 (0) 5.0 (5).5 (80) 4.5 (60) 6.5 (65).5 (0) 0 (05) (0) 0 (80) 8.5 (40) (60) 7.5 (40).0 (495) 0 (90) 8.0 (85).0 (565) (75) 0.0 (495) 4.0 (70) (470).0 (65) 7.0 (90) Note Unit length00m Current carrying capacitypage 8 see table.
7 Core identification (Color code) << Multi pair Type >> Pairs Pairs 4Pairs 5Pairs 6Pairs 8Pairs 0Pairs Pairs 6Pairs 0Pairs Table Color code multi pair type. pairs 46pairs 70pairs 5pairs 60pairs pair st.cond. nd.cond. st.cond. nd.cond. st.cond. nd.cond. st.cond. nd.cond. st.cond. nd.cond. Black Brown Black Brown Black Brown Black Brown Black Brown Black Red Black Red Black Red Black Red Black Red Brown Red Black Orange Black Orange Black Orange Black Orange 4 Brown Red Black Yellow Black Yellow Black Yellow 5 Brown Orange Brown Red Black Green Black Green 6 Red Orange Brown Orange Brown Red Black Blue 7 Brown Yellow Brown Orange Brown Red 8 Red Orange Brown Yellow Brown Orange 9 Red Yellow Brown Green Brown Yellow 0 Orange Yellow Red Orange Brown Green Red Yellow Brown Blue Red Green Red Orange Orange Yellow Red Yellow 4 Orange Green Red Green 5 Yellow Green Red Blue 6 Orange Yellow 7 Orange Green 8 Orange Blue 9 Yellow Green 0 Yellow Blue << Multi core Type >> Re Re Br Bl Br Re Or Br Bl Re Ye Br Or Re Bl cores cores 4cores 5cores 6cores 8cores 0cores Vi Br Ye Or Bl Re Or Ye Br Or Ye Re Br Or Ye Re Br Re Re Or Ye Re Br Re Re Re Re cores 6cores 0cores Note:Black, Re:Red, Br:Brown, Bl:Blue, Or:Orange, Ye:Yellow, Vi:Violet, Gray:.
8 Expectation flex life () Foreword NASA has metal fatigue experiment formula which is relationship between bending radius and stress strain. We developed way to the expecting the flex life cables by our bending test data and metal fatigue experiment formula NASA. () Expectation curve flex(bending) life <<Formula>> d Stress strain R t D () Example Following table is examples specimens. Descreption Bending radius* Stress strain RBT -V(SB) 6P0.mm RBT -V(SB) 6P0.mm d: Conductor diameter R: Bending radius t: Sheath thickness + shielding thickness + bind tape thickness D: Insulation diameter Expected flex life 90bending U-bending 57mm mm Approx Approx. 0 7 Bending radius is 6 times sheath diameter. (Our recommended condition) Bending Radius Specimen Stroke Bending radius W Fig. ±90 bending Weight Fig. U-bending
9 Current carrying capacity The current carrying capacities are given by following tables. The following data is conditioned on single cable wiring in free air at ambient temperature 40degree C. pair Table Current carrying capacity RBT -V cable. Current carrying capacity core 0.4mm 0.mm 0.mm 0.56mm pair Table Current carrying capacity RBT -V cable. Current carrying capacity core 0.mm 0.mm 0.5mm 0.75mm.5mm mm Note; If many cables are bundled, current carrying capacity multiplied by adjustable factor;f as following table. bundled cables Adjustable factor ; Note; If the ambient temperature is not 40degree C, current carrying capacity multiplied by adjustable factor;t as following table. Ambient temperature() Adjustable factor ; T
Industrial Cable for Factory Automation
Industrial Cable for Factory Automation Line up Multi core & multi pair cables for high flexure part. Heat bonded flat cables for high flexure part. Multi core PVC cables for fixed part. Large size PVC
More informationSafeX110 Single Core Flexible Tinned Copper Cable
LSZH 110 C Flexible SafeX110 Single Core Flexible Tinned Copper Cable Application: Wiring of switchboards, control, general wiring, instrumentation and communication systems. Used where low smoke, zero
More informationType 1 Machine Cable. Oxygen free tinned annealed copper wire interwoven with high tensile poly-yarn
Mining Cable Type 1 Machine Cable Application: Typically used for interconnection of control boxes or motors on non-mobile or fixed apparatus. Used when exposure to heat is not an issue and where added
More informationData sheet chainflex CF887
1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Filling: Plastic yarns 4. Core insulation: Mechanically high-quality, especially low-capacitance
More informationAvailable in 0.75 to 16.0 sq mm. Red, Yellow, Blue, Black, White, Gray and Green (for earthing) Specification IS 694:1990
Application These cables are used for wiring domestic and coercial buildings. The multi strand flexible conductors make it ideal for concealed wiring. These cables are ideal for wiring in residential and
More informationSPECIFICATION FOR THHN/THWN-2/THW/THWN/TW ARROW ROUTE, FONTANA CA
SPECIFICATION FOR THHN/THWN-2/THW/THWN/TW THHN/THWN-2/THW/THWN/TW Listed E-492385 / E-472248 APPLICATIONS THHN/THWN-2 building wire is primarily used for general purpose applications in conduit and cable
More informationSpecification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.
Spec. No. GO 5821-4361Rev.2 Issued date : July 13, 2005 Revised 1 date : April 29, 2015 Revised 2 date : February 19, 2016 Specification FOR 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated
More informationHighly flexible, screened control cable with PVC core insulation and abrasion and oil resistant PUR sheath
Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant PUR sheath - Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant
More informationSeparator, suitable tape between the braid and outer sheath
Picture is for information only. Applicable standards: NEK TS 606 Code S1/S5, IEC 60092-376- Design guidelines IEC 60228 conductor IEC 60092-351 Insulating material, IEC 60092-359 Sheathing materials IEC
More informationSuperastic Flex Cable 450 / 750V Exceeds all the specifications in its category.
Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category. Superastic Flex Extra sliding for extra easy installation. Superastic Flex cables are ideal for those who want to save installation
More informationMEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]
[6.35/11kV Copper XLPE Three-Core HDPE Sheathed] APPLICATION Mostly used as feeder electric cable for power distribution network such as power supply station, substation, switching system etc. They are
More informationH-FLEX CABLES 10/2017
10/2017 H-FLEX CABLES CONTENTS H-FLEX PWR PUR 0,6/1kV...2 H-FLEX PWR C-PUR 0,6/1kV...6 H-FLEX CTL PUR 250V...10 H-FLEX CTL C-PUR 250V...12 H-FLEX INS PUR 250V...14 H-FLEX INS C-PUR 250V...16 TECHNICAL
More informationHighly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified
Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified - Screened power and control cable for versatile use in power chains with UL/cUL AWM certification.
More information0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath
0.6/1 kv LOW VOLTAGE CONTROL CABLES PVC OR XLPE INSULATED, PVC SHEATHED AS PER IEC 60502-1 Conductors Conductors shall be Circular Stranded, Class 2 as per IEC 60228, BS EN 60228. Upon request, Solid Circular
More informationHighly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified
Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified - Screened power and control cable for versatile use in power chains with UL/cUL AWM certification.
More informationConstruction guideline
1/6 1) SUMMARY OF ABBREVIATIONS FOR CABLE CONSTRUCTION ELEMENTS MSR - : EUPEN code for INSTRUMENTATION CABLES JE - : cable for INDUSTRIAL ELECTRONICS RD - : cable for CONTROL SYSTEMS INSULATION MATERIALS:
More informationMineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths
Datasheet ENGLISH Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths High temperature, rugged, flexible Pt100 probe Suitable
More informationCaledonian Cables Ltd
Caledonian Motor Connection Cable Caledonian Cables Ltd s 1 Addison Addison Motor Connection Cable Company Profile Caledonian. established in 1978.offers one of the most complete lines of fiber and copper
More informationSpecifications of. Single Armored Optical Fiber Cable
SPEC. NO A15022701 Sheet no.1 of 7 Date: 15-02-27 Specifications of Single Armored Optical Fiber Cable (GYFTS) 1. General SPEC.NO A15022701 Sheet No.2 of 7 1.1 This specification covers the requirements
More informationWHITE PAPER Flex Life vs Flexibility
WHITE PAPER Flex Life vs Flexibility The design criteria for both flex life and flexibility is the same but the properties and application of the elements can be vastly different. The design elements are
More informationCeramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code
Datasheet Platinum Resistance Pt100 Tubular Ceramic Insert Elements with tail wires 2 or 4 wire with choice of Teflon or nickel/glassfibre insulated tail wires up to 450mm long ENGLISH 237-1635 237-1641
More informationFlexible Cables for Cranes and other industrial applications
Flexible Cables for Cranes and other industrial applications Fujikura Ltd. Version 3 Update Aug.13, 2014 1 Cable selection depending on the application Application 2/3PNCT-B G-/3PNCT-B 2/3PNCT-H 2/3PNCT-H-U
More informationData sheet chainflex CFSPECIAL.182
Ethernet (CAT5/CAT5e/GigE/PoE) Profinet (Type C) 1 / 8 Cable structure Conductor Core insulation Stranded conductor in especially bending-resistant version consisting of bare copper wires (following DIN
More informationSingle core conductor BETAtherm 145
Internet: www.synflex.de Single core conductor BETAtherm 145 Description BETAtherm 145 is a flexible low-voltage cable with UL recognition consisting of a tinned copper stranded wire and insulated with
More informationPlatinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves
ENGLISH Datasheet Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves Pt100 Autoclave & steriliser drain temperature probe For use to monitor the fluid
More informationInstrumentation Cables
Instrumentation Cables Product Catalogue Factories and Regional Offices Tai Sin Electric Limited 24 Gul Crescent Jurong Town Singapore 62953 Tel: (+65) 6672 9292 Fax: (+65) 686 4084 E-Mail: sales@taisin.com.sg
More information6A-38 Jumper Wire (IJP) (Rank A)
DISCLAIMER: This translation may be used for reference purpose only. This English version is not an official translation of the original Japanese document. In cases where any differences occur between
More informationSPECIFICATION FOR FRLS POWER CABLES
SPECIFICATION FOR FRLS POWER CABLES 1.0 SCOPE This specification cover the technical requirements of design, manufacture, testing and delivery to site of Power Cables of 1100V grade with FRLS PVC Sheathed,
More informationENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead
ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead (Image shows 4 wire) Pt1000 element to IEC 751 Class B 2 wire configuration Temperature range -50 C to + 200 C Pt1000
More information26/35kV Copper XLPE Insulation Electric Cable
26/35kV Copper XLPE Insulation Electric Cable Specifications 1.1~35kv XLPE insulated power cable 2.Standard: IEC,VDE,BS,UL,AS/NZS Black PVC sheath XLPE insulated armored copper power cable YJV22 YJV32
More informationInside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR
Category 6 Plus Plenum Category 6 Plus Plenum has a cross web design for maximum pair separation. It features sequential footage markings that count down to zero feet -- removing the guess work concerning
More informationThis product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.
AFC Cable Systems, Inc. Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519.13 METAL CLAD CABLE-MC
More informationYKY, YKY-żo 0,6/1kV PN-93/E-90401, PN-HD-603 S1, IEC
PVC insulated and PVC sheathed power cable CONSTRUCTION Conductors: annealed copper solid class 1(RE), circular or circular compacted stranded conductor class 2 (RM, RMC) or stranded sector shaped conductor
More informationM-FLEX CONTROL CABLES
M-FEX COTRO CABES Flexible, workable and environmentally resistant. FOR IDUSTRY Your reliable partner for integrated industrial cable solutions. Prysmian Group is world leading in the development and production
More information600 VOLT 600V, 3 CONDUCTOR (WITH GROUND), FR-EPR OR FR-XLPE INSULATION, PVC JACKET SPECIFICATIONS (FLAME RETARDANT POWER CABLE) (UL TYPE TC-ER) TYPE C3 SPEC 70.0100 PROJECT 196116 REFERENCE: LATEST EDITIONS
More informationPRODUCT INFORMATION ÖLFLEX CRANE. Info Suitable for outdoor use Integrated supporting element Also suitable for power chains and cable trolley systems
Highly flexible and weather-proof rubber cables with support element - flexible cable, flame retardant for outdor use and crane applications/conveyour technology, power and control rubber cable, U 0 /U:300/500V
More informationSpecifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)
ENGLISH Datasheet Platinum Resistance Pt100 Wire-Wound Detector Elements Pt100 platinum resistance thermometer elements in a choice of sizes single & dual element Pt100 elements to IEC 60751 Class A or
More informationHighly flexible control cable with PVC core insulation and PVC sheath - certified for North America
Highly flexible control cable with PVC core insulation and PVC sheath - certified for North America - Power and control cable for versatile use in power chains with UL/cUL AWM certification Info Basic
More informationENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)
ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm) Pt100 Elements, Thin Film (100 Ohm) Pt100 elements to IEC751 Class A,
More informationElectric cables. CRANES APPENDIX
Electric cables. CRANES APPENDIX Electric cables for mobile connections. Aristoncavi spa reserve the right to modify the data in this catalogue without notice. 06/0 Copyright Drawings and technical descriptions
More informationWires & Cables for Space Applications
Wires & Cables for Space Applications Aerospace Business Unit Draka Fileca S.A.S. is part of the Prysmian Group, the world leader in the cable systems industry, listed on the Milan Stock Exchange. With
More informationENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead
Datasheet Platinum Resistance Pt100 Sheathed Thin Film Strip Sensor 2 wire sensor sheathed in a thin stainless steel shim body ideal for surface measurement ENGLISH Sheathed Pt100 element in a thin, flat
More informationNUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0
REVISION NO. 0 NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0 PAGE NO. 1 OF 24 DATE OF ISSUE (MONTH/YEAR) TOTAL NO. OF PAGES (Including cover
More informationMANUFACTURER'S QUALITY ASSURANCE PLAN (QAP - Instrumentation cables)
POLARIS CABLES & WIRES PVT. LTD. (An IS & ISO 9001 :2000 Certified Company) Plant : Plot 35, Genesis Indl Complex, Kolgaon, PALGHAR, Dist :Thane, Maharashtra. MANUFACTURER'S QUALITY ASSURANCE PLAN (QAP
More informationCables for Drag Chains
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 21 Owings Mills, MD 211 USA web: http://mdmetric.com ph: (4)35-3130 (00)3-30 fx: (4)35-32 (00)72-9329 email: sales@mdmetric.com RFQ form:
More informationSERVICE ENTRANCES. OPPD S Electrical Service Designer (ESD) shall designate the Point Of Entrance.
SERVICE ENTRANCES 3.01 POINT OF ENTRANCE General Service The customer, or the customer s electrician, should provide OPPD with a site plan, load schedule, and voltage requirements when requesting service.
More informationPt100 (100 0 C) to IEC 751, Class B, 4 wire 3.0, 4.0, 4.5 or 6.0mm diameter 316 stainless steel sheath.
Datasheet Platinum Resistance Thermometer Pt100 Industrial Sensor Probe, Class B Available in 3.0, 4.0, 4.5 or 6.0mm diameter x Various probe lengths ENGLISH Multipurpose Pt100 Probe to IEC751 Class B,
More informationCompact Module. Enhanced Category 5 FTP Cabling System
Compact Module Enhanced Category 5 performance Suitable for Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro modules and blanks Individually QA tested Easy to use
More informationConnecting the world through technology and quality
Connecting the world through technology and quality G. K. Enterprises (P) Ltd. An ISO 9 : 28 Certified Company Unit I - C-, Sector 58, Noida -23 (U.P.), (India) Unit II - C - 6, Sector 58, Noida -23 (U.P.),
More informationConductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.
37-105VFD MMV-VFD Power Cable Three : kv - 15kV 133% Level Rated 90 C s (3) Soft annealed flexible stranded tinned copper per IEEE 150 Table 11. Extruded thermosetting 90 C Ethylene Propylene Rubber (EPR),
More informationManhattan Thermocouple Cable
Manhattan Thermocouple Cable Temperature Measurement and Control The measurement of temperature is one of the most vital functions in the control of manufacturing and processing operations. As demands
More informationComparison of BS 5308, PAS 5308 and BS EN
Comparison of BS 5308, PAS 5308 and BS EN 50288 Scope BS 5308 Part 1: 1986- Instrumentation Cables Part 1. Specification for Polyethylene Insulated Cables (withdraw, superseded by BS EN 50288-7) BS 5308
More informationReeling Cables www.sab-worldwide.com CONTENT page The Company....................................................................................................... 2 DR 717 P Highflex 300/500 V.........................................................................................
More informationDatasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths
Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths ENGLISH Duplex PRT s with two independent PT100 detectors inside tip of probe. This
More informationKaf-Tech Product Specification
Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519.13 METAL CLAD CABLE-LUMINARY CABLE
More informationCables for robots www.sab-worldwide.com CONTENT page < The company............................................................................... < Clientele / supplier numbers........................................................................
More informationSERV-RITE Wire and Cable
SERV-RITE SERVTEX Insulated Extension Wire Series 155 STOCKED FOR SAME DAY SHIPMENT K16/5/155 K16/7/155 E N J S K T 2-3. 20 16 14 20 stranded (7/28) 16 stranded (7/24) 14 stranded (7/22) 4. Type/Tolerance
More informationENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with DIN B Head
ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with DIN B Head With stainless steel plug (no thread) Pt100 probe with DIN B terminal head Class B, 4 wire connection Various
More informationCONSULTATIONS TECHNICAL GUIDELINE. HVDC extruded cable
UNIT, BU1SNESS AREA OUR REFERENCE TR14-02-2E DATE 2018-01-24 CONSULTATIONS TECHNICAL GUIDELINE EDITION 1 APPROVED HVDC extruded cable This technical guideline describes the basic design and construction
More informationTitle Cables for Railway Signalling Applications - Traction Return Bonding and Track Connection Cables
Discipline Engineering Standard NSW Category Signalling Title Cables for Railway Signalling Applications - Traction Return Bonding and Track Connection Cables Reference Number SPS 49 - (RIC Standard: SC
More informationTI 20 PVC TI 20 INSULATED TELEPHONE WIRE
TI 20 PVC TI 20 INSULATED TELEPHONE WIRE Standard: Nominal voltage: Temperature range - fixed laying: Cable Structure: Application: Packing: 2x0,5 0,4 2,6 3,6 7,2 2x0,6 0,4 2,8 5,2 9,1 2x0,8 0,4 3,2 9,2
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS PAGODA CABLES PVT. LTD. 1/58, STREET NO: 3, VISHWAS NAGAR, SHAHDARA, DELHI 110 032. (INDIA) TEL/FAX : 91-11-22392801, 22385391. Email : pagoda @del2.vsnl.net.in CONTENTS: 1. 2.
More informationArticle-No. Type. All dimensions in mm. Subject to technical changes. Other dimensions, reel lengths or colours available on request.
4.4 Installation Devices HelaTape HellermannTyton offers a wide range of PVC and rubber tapes for sealing, insulation and bundling of cable and conduits. PVC based tapes are designed for low voltage applications
More informationCables de Comunicaciones Zaragoza. CW1601 Approval application.
1. GENERAL INFORMATION 1.1 LIST OF CONTENTS Cables de Comunicaciones Zaragoza. CW1601 Approval application. 1. General Information 1.1 List of Contents 1.2 Contractors Name 1.3 Test report 1.4 Product
More informationPlatinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing
Datasheet ENGLISH Platinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing Pt100 Patch Sensor (100 Ω Ohms @ 0
More informationHalogen-free data transmission cable with colour code acc. to DIN resistant to a wide range of chemical media
Halogen-free data transmission cable with colour code acc. to DIN 47100 - resistant to a wide range of chemical media :Screened low-freq data cable Twisted pairs Biopetroleum/ cleaner/ hotwater/ hydraulic
More informationMATERIAL STANDARD FOR CABLES AND WIRES
MATERIAL STANDARD FOR CABLES AND WIRES CONTENTS : PAGE No. 1. SCOPE... 2 2. SERVICE CONDITIONS... 2 3. REFERENCES AND STANDARDS... 2 4. UNITS... 3 5. CABLE DESIGN AND CONSTRUCTION... 3 5.1 Applicable Cable
More informationJAMES MONROE. WIRE & CABLE CORPORATION ETT Traveling Cable Hoistway Cable Compensating Cable Stationary Communications Cable ELEVATOR CABLES
WIRE & CABLE CORPORATION ETT Traveling Cable Hoistway Cable Compensating Cable Stationary Communications Cable ELEVATOR CABLES Elevator Hoistway & Traveling Cables... Designed for high performance and
More informationPlatinum Resistance Thermometer Pt100 Precision Probe - High accuracy platinum resistance thermometer probe, 6mm diameter x 250mm
Datasheet ENGLISH Platinum Resistance Thermometer Pt100 Precision Probe - High accuracy platinum resistance thermometer probe, 6mm diameter x 250mm Precision Pt100 sensor offering high accuracy over the
More informationYF /8" YF /2" YF /4"
Wire Over-Braided Flexible Conduit ( YF-705 ) most suitable for demanding industrial wiring applications. *Galvanized steel helically wound with PVC coating and wire over-braid. *Trade size: 3/8"~2" (square
More informationaccording to UL AWM 758, Style and based on EN resp. VDE
Application ÖLFLEX SERVO FD 798 CP cables are high-flexible, screened, oil-resistant, halogen free, signal (encoder and resolver) cables with an outer sheath of Polyurethane. They are designed for use
More informationPURENET-U (Part No.: U RXX2, U PXX2)
ISSUED: FEB. 3, 2010 PAGE : 1 OF 6 PURENET-U5350-00 (Part No.: U5350-04-RXX2, U5350-04-PXX2) for 4 PAIR UTP CABLES (ENHANCED CATEGORY 5E) ( Ref.: UL 444, ANSI/TIA/EIA-568B.2 & ISO/IEC 11801,IEC 61156-5
More informationCABLEMASTER CABLE GUIDE
CABLEMASTER COAXIAL, DATA, TELEPHONE & SPECIAL CABLES CABLE GUIDE REFERENCES: FOXTEL F10231, F30128 OPTUS SAP17874, SAP4868 AS/ACIF S008:2001 N2020 Skandia Pty Ltd Issue: 2.0 Revision: 1 Date of issue:
More informationRG-59, RG-59+2DC, UTP CAT6, SFTP CAT6
FLAT ELEVATOR CABLE RG59, RG59+2DC, UTP CAT6, SFTP CAT6 COPPER SERIES MAIN FEATURES ASTEL RG59 Lift Monitor cablescopper Series are designed and manufactured to Ultra flexibility demand of CCTV Cameras
More informationPRODUCT SPECIFICATION
Sep., 2005 PAGE / 8 Jan. 20, 2007 PRODUCT NAME : STW-F RATING : 55 C, 000V rms No. Revised Date Revised Details Page Report Jan. 20, 2007 Emendation of Specification All - REPORTED BY: APPROVED BY: Q.M.
More informationEnergy Chain System Training
Energy Chain System Training 1. Energy Chain Cable Carriers 2. ChainFlex - Continuous Flex Cables 3. Types of Installations 4. Specifying an E-Chain System / Important Design Considerations Energy Chain
More informationSection ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR
PART 1 - GENERAL Section 26 05 15 SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR 1.1 Cable shall be 15 kv, shielded, three conductor with ground, stranded copper, with continuously welded and corrugated
More information150 mm. 1/8 BSPP brass male compression fitting with locknut included
ENGLISH Datasheet Platinum Resistance PT100 Flat Tip Probe 4mm diameter x 150mm long 2 wire with 1 metre flying lead, complete with 1/8 BSP compression fitting & locknut 4mm 25mm 5.5/6mm(max) 150 mm General
More informationNEMA Standards Publication No. WC ICEA Publication No. S
NEMA Standards Publication No. WC 71-1999 ICEA Publication No. S-96-659-1999 Standard for Nonshielded Cables Rated 2001-5000 Volts for use in the Distribution of Electric Energy Published by National Electrical
More informationCopper Cable Company Limited
Cables and Wires Copper Cable Company Limited Copper Cable Company is the UK subsidiary of TELE-FONIKA Kable S.A., with offices and a warehouse centrally located in Leicestershire. 2 A major supplier to
More informationFour Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable
Edition Nº: 9 THE ISRAEL ELECTRIC CORPORATION LTD. Specification No. NPS-76 for Four Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable for Rated Voltage U0/U = 0.6/1.0
More informationENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting
ENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting RJT unions (Ring Joint Type) are often referred to as a standard union. The compromise of an O-ring style gasket
More informationArmoured Instrumentation Cables to BS7917
Armoured Instrumentation Cables to BS1 Fire Resistant, Pairs/Triples - Collectively Screened. Low Smoke Zero Halogen TAC, MGT, EPR, SCRN, ZH, GSWB, SW 0/0V Application Control and instrumentation cable
More informationSECTION ELECTRICAL CABLE. 1. Trench excavation, backfill, and compaction; Section
02735-1 of 5 SECTION 02735 ELECTRICAL CABLE 02735.01 GENERAL A. Description Electrical cable installation shall include, but not necessarily be limited to, furnishing and placing electrical cable as shown
More information3M Round, Shielded/Jacketed, Disc. Wire Cable 26 AWG Solid, Twisted Pair, PVC/PVC 3560 Series
M Round, Shielded/Jacketed, Disc. Wire Cable 26 AWG Solid, Twisted Pair, PVC/PVC 560 Series Twisted pairs reduce crosstalk for balanced drive applications Dual shielding provides 5 db average shielding
More informationTECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1
ANNEXURE TO TENDER NO. PUR42396GM DATED 06 th FEBRUARY 2014 SUPPLY OF 1.1KV GRADE LT POWER CABLES FOR THE PERIOD APRIL 2014 MARCH 2016 TECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1 1.1 SCOPE
More information*Nominal values are to be used as guidelines only; this is not a product specification and does not indicate minimum or maximum values.
UNITED POLY SYSTEMS C O N D U I T Applications include: Installation: T e l e c o m, E n e r g y, D O T, E t c. E x i s t i n g C o n d u i t, P l o w, D i r e c t B u r i a l, H D D ( H o r i z o n t
More informationENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument
Datasheet ENGLISH Platinum Resistance Thermometer Pt100 Outdoor/Cold Store Temperature Sensors IP67 Weatherproof Housing, 4 wire single or dual element, or 4-20mA option Weatherproof IP67 rated wall mounting
More informationPhoto: HELUKABEL. Robotic Cables H 1
Photo: HELUKABEL Robotic Cables H 1 Robotic Cables With over 30 years of experience with cables and lines, we also have the right solutions for the demands placed on the components to be installed by the
More informationDATA SHEET Single Core 2HR Fire Rated Cable
Features: 2HR Fire Rated 0.6/1kV Insulation Rating 110 o C Continuous Operation AS/NZS 3013 WS52W AS/NZS 5000.1 AS/ACIF S008 RCM Certified Low Smoke Zero Halogen Flame Retardant Flexible Class 6 Conductors
More informationCables for Railway Signalling Applications General Requirements
Discipline: Engineering (Signalling) Category: Procedure Cables for Railway Signalling Applications General Requirements ESA-11-01 Applicability ARTC Network Wide Primary Source ESA-02-01 Document Status
More informationDRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)
EDC3 (5239) P3 Mini-Grid Systems DRAFT TANZANIA STANDARD Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV) TANZANIA BUREAU OF STANDARDS TBS 2017 First Edition 2017 Table of Contents
More informationEngineering Data for Copper and Aluminum Conductor Electrical Cables
2018 Edition Engineering Data for Copper and Aluminum Conductor Electrical Cables THE OKONITE COMPANY Okonite Cables...A higher Standard! The Okonite Company, 2018 Okonite Cables Table of Contents SECTION
More informationThis product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.
Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519 METAL CLAD CABLE - MC-PLUS Neutral
More informationTECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION 4 PAIR UTP CABLE CAT6 (CATEGORY 6 PLUS) Page 1 of 5 1. SCOPE This specification is based on the specifications of UL 444, ANSI/TIA/EIA-568-B,ISO/IEC 1801, UL 1685(CM) and covers
More informationTip Jacks. Johnson Components P.O. Box 1732 Waseca, MN Fax:
.060" (1.5 mm) Shrouded Tip Jack (Solder or Crimp) 5.060" (1.5 mm) Uninsulated Tip Jack (Solder or Crimp) 5.060 (1.50) Shrouded Tip Jack (Solder or Crimp) 5.060 (1.50) Uninsulated Tip Jack (Solder or Crimp)
More informationSOFC-DA-180KN-192 G652D
Description The design of the offered cable has been a typical structure of submarine cables which is prevailing over the world and has been approved for stable performance in submarine cable system. Loose
More informationQualification Reference: AA/ Cage Code: MIL-C Cables NEMA WC27500 Part Number Builder
Qualification Reference: 15404201.AA/1-20-2015 Cage Code: 67050 MIL-C-27500 Cables NEMA WC27500 Part Number Builder MIL-C-27500 Cables NEMA WC 27500 Part Number Builder MIL-C-27500 (M27500 Cable) MIL Spec
More informationMGO INSULATED THERMOCOUPLES INDEX
MGO INSULATED THERMOCOUPLES INDEX PAGE General Information... M1 Part Numbering Examples... M4 Thermocouple Elements (MA)... M5 Leadwire Style Thermocouples (MB)... M6 Leadwire Style Thermocouples (MD,
More informationWire and Cable SPEC 44 Wire and Cable
High-performance wire and cable sulation system for 65 C to Wire and Cable SPEC 44 Wire and Cable Applications Hookup and signal wire and cable used aircraft, avionics, military electronics, satellites,
More information