1 April 4, 2016 ADDENDUM 3 TO: FROM: RE: Vendors Vianka Colin, Purchasing Director INVITATION TO BID ITB/FFS-15/16-79 CONSTRUCTION OF A BUILDING FACILITY AT INDIAN LAKE RANGER STATION This addendum is to provide all potential bidders with answers to questions submitted in reference to Invitation To Bid number ITB/FFS-15/ Deletions are struck through, and additions are highlighted. Questions / Answers 1. The landscape shows 17 large tree-type symbols and labels as a hedge 3 ft. in height. Could we get a clarification as to what these items are? The trees shown on the plan have to be 8 ft. in height. Is there a caliper requirement? See the revised plans. 2. There are not specifications provided on the well size, pump size, tank size, etc. Will there be an engineered detailed site plan for this project? See the revised plans. 3. Who is the power company? Has load been calculated for service to be built? Ocala Electric Utility is the utility company. The load shall be calculated by the contractor. 4. Will there be any additional cost to build service and supply O/H to site? This shall be covered by FFS. 5. Where will the O/H service line terminate or be located on site property? It is unknown at this time.
2 ADDENDUM 3 April 4, 2016 Page 2 6. Is the contractor to include U/G costs from pole to service meter can? If so, is there an estimated cost/budget? This shall be the contractor's responsibility; there are no estimates. 7. Will NOVA be responsible for coordination and costs associated with State Fire Marshal as described in ITB? Yes. 8. Is the contractor to include costs associated with surveys/staking/layouts/as-builts, or is owner responsible for all? This shall be the contractor's responsibility. 9. Is contractor responsible for all testing (compactions/concrete/proctors, etc.) costs and should include in bid? Yes. 10. Are we required to use firm supplying Geo-Tech report for testing if required? No. 11. Any other jurisdiction or authority requirements/permits/approvals needed prior (besides DOH)? State Fire Marshall. 12. Will electronic submittals regarding materials be acceptable? Architect to review? Return/review time? Electronic submittals are acceptable. The architect will review and return as soon as possible. 13. References requirement in bid should be for similar work, not roofing as ITB lists, correct? Correct. 14. Civil/Site specifications needed for all well and associated systems equipment. See the revised plans. 15. Are civil/site specifications needed for all fire tank & suppression source systems equipment? A 10,000 gallon fire suppression tank per nfpa Civil/Site Plans? See the attached revised plans. 17. We need plans/details for the pole barn building. There is no pole barn at this time.
3 ADDENDUM 3 April 4, 2016 Page What is the plate height of the exterior walls? The elevations show 9, the sections show 10 4? Which is correct? 9 is correct. 19. I can t find a Hardie bond board freeze, please advise? The band/trim is called a frieze but is just a 10 piece of trim. 20. Sections appear to show a 2" x 6' sub fascia with a 1" x 2' drip. The plans call out a 1" x 6' fascia with a 1" x 2' drip. Will the 1" x 6' be a finished product or wrapped? Is there a sub fascia behind the 1" x 6' or is this the fascia? The project requires a 1" x 6' fascia, 2" x 4' pt sub-fascia. 21. Please provide specs/sizes for the fire suppression tank. See the answer to question Please provide specs on hooking up electric to fire suppression tank. Install electrical for fire suppression tank per NFPA Please confirm offsite electric to onsite electric locations. Unknown at this time. 24. What size water heater does the owner want? Please provide specs. See the electrical plan specifying an instant hot water heater. 25. What are the carpet and tile specs? There are none. Contractor shall submit samples for approval. 26. Are there any specs for backsplash? No Contractor shall submit samples for approval. 27. Are there any specs for cabinets and counters? No. Contractor shall submit samples for approval. 28. Are there any specs on interior framed walls? I assume 2x4 walls. 2" x 4' interior walls. 29. Is there any sound insulation? No. This is not a part of the project. 30. Is proposed fence by contractor or owner? If by contractor are there any specs? This shall be provided by the contractor. It shall be 6' chain link per DFOT index 802.
4 ADDENDUM 3 April 4, 2016 Page Are there any specs for the Well? See answer to question Is the administration building the only building being constructed? Yes. 33. There is a size discrepancy regarding the size of the administration building on the civil plans vs the architectural plans. See the attached plans. 34. In addition to a bond, is builder s risk also required? Yes. 35. How will the power be brought in? Power will be from underground to the building from the last pole. The Department is waiting on the utility company for more information. 36. Will power locations be provided on the Civil plans? No. Contact the local power company, Ocala Electric Utility. 37. Who is the power service through? Ocala Electric Utility. 38. Who is responsible for electrical meter fees? Contractor. 39. Who is responsible for any testing fees such as soil or otherwise? Contractor. 40. Please provide size and specs for well and septic. Please see the revised plans. 41. What permit related fees is the contractor responsible for? None. 42. What permit related fees is the owner responsible for? All. 43. How should bidders obtain project information such as addendums? Contact the purchasing office at (850) or Vianka.Colin@FreshFromFlorida.com.
5 ADDENDUM 3 April 4, 2016 Page A-2 shows 2' o/h, A-3 shows 2'6"; please confirm. The correct measurements are 2-6 o/h at porch, 2-0 o/h at building. 45. Will there be a 2x4 sub fascia for soffit nailer and to help keep 1x6 fascia straight? Yes, 1" x 6' fascia, 2" x 4' pt sub-fascia 46. Is permacast column a split column? We will not be able to install HD to 4x4 inside column? Permacast is structural, is 4x4 needed? This project requires a 4" x 4" inside split PermaCast column. To the extent this addendum gives rise to a protest, failure to file a protest within the time prescribed in Section (3), Florida Statutes, shall constitute a waiver of proceedings under Chapter 120, Florida Statutes. All other terms, conditions and specifications of this Invitation to Bid will remain the same. If you have any questions regarding this addendum, please feel free to contact this office at (850)
6
7 GENERAL CONSTRUCTION NOTES PAVING AND GRADING NOTES: UTILITY NOTES PROPOSED LEGEND GROUND SPOT ELEVATION GROUND SPOT ELEVATION (MATCH EXISTING GRADE) MATCH EXISTING GRADE MITERED END SECTION (MES) AND STORM PIPE CENTERLINE APPROX. FILL LIMIT APPROX. CUT LIMIT SETBACK LINE WM SAN WATER MAIN SANITARY SEWER SEPTIC TANK & DRAIN FIELD W WATER WELL CRUSHED LIMEROCK LIMITS SLAB ON GRADE BUILDING TREE PROTECTION NOTES SECTION IDENTIFICATION SHEET NUMBER DETAIL IDENTIFICATION SHEET NUMBER EROSION & POLLUTION CONTROL NOTES CLEARING AND PREPARATION NOTES: F.F. EL. R.O.W., R/W F&I MATCH/MEET EXISTING GRADE FINISHED FLOOR ELEVATION FURNISH AND INSTALL...Providing Solutions
8 TREE TABLE TOPOGRAPHIC SURVEY OF BENCMARK #2 BENCHMARK #1 NE 40TH AVENUE ROAD LEGEND EXISTING TREE (TYP.)...Providing Solutions SURVEYOR'S REPORT 1. The survey date is August 12, 2015 (last date of fieldwork). 2. This is a Topographic Survey as defined by Chapter 5J (10)(k) of the Florida Administrative Code. 3. This Topographic Survey map and report or the copies thereof are not valid without the signature and the original raised seal of a Florida licensed surveyor and mapper. 4. Additions or deletions to Survey maps or reports by other than the signing party or parties is prohibited without written consent of the signing party or parties. 5. Copyright 2015 by MacSurvey, Inc. 6. The bearings shown upon this Survey are based on Grid North as established by the National Ocean Service ("NOS") through its program office National Geodetic Survey ("NGS") and the bearing between NGS control point "FLGPS " and NGS control point "FLGPS33 AZMK 1989" being N47 35'57"W. 7. Elevations shown heron are referenced to the North American Vertical Datum of 1988 (NAVD88) as established by a NGS benchmark being a stainless steel rod in a NGS access cover stamped "FLGPS " with an elevation of.60'. 8. The coordinate system utilized hereon is relative to the Florida State Plane Coordinate System, West Zone, North American Datum of 1983, 2011 adjustment as established using the control points described in Note #6 and conventional field survey methods. All distances shown hereon are in US Survey Feet (grid). 9. Aerial imagery shown heron was provided by the Florida Department of Environmental Protection ("FDEP") and is shown for informational purposes. The imagery was flown in Field work performed by Columbia America, licensed Florida Surveying and Mapping Business #79, last date in the field 8/12/ The features on this survey that were intended to be topographically mapped include existing topography and existing improvements within the project limits provided by the Florida Forest Service. 12. The scale of this Survey may have changed due to reproduction. SURVEY PROVIDED BY: MacSurvey, Inc. 13. Wetland lines determined by
9 BENCMARK #2 BENCHMARK #1 NE 40TH AVENUE ROAD 37.1' 85.4' 48.4' 49.0' 86.0' 37.0' R40.0' R R R40.0' 29.2' F.F. EL.=.50 BLDG ADMIN. 24.0' R36.0' R3.0' R1 18.0' 93.0' 12.0' 39.1' 38.9' PROPOSED 87.2' PROPOSED SWALE 6" DEEP 4' WIDE AT INLET PROPOSED 99.2' PROPOSED RIP RAP FLUME WEIR (SEE DETAIL ON THIS SHEET) SKIMMER 42.7' PROPOSED POND TOP OF BANK = 65.5 BOTTOM = '.5' 30.0' 9.2' PROPOSED REGULAR PARKING SPACE 103.8' (PROPOSED LIME ROCK) 12.0' 6.0' 24.9' 24.0' 18.0' 9.0' R 93.0' R17.0' R 24.0' PROPOSED FIRE SUPPRESSION TANK WITH SIAMESE FDC CONNECTION 21.2'...Providing Solutions PROPERTY SITE INFO: AREA 62,8 S.F AC. PROPOSED IMPERVIOUS ADMIN BUILDING 2,240 SF AC. POLE BARN BUILDING 3,0 SF AC. LIME ROCK 11,351 SF AC. 5,502 SF AC. TOTAL 22,793 SF AC. PARKING (10) 18'x9' REGULAR PARKING SPACES PROVIDED (1) 18'x12' HANDICAP PARKING SPACE PROVIDED SITE INFO: DRAINAGE DATA: IMPERVIOUS AREA: TREATMENT VOLUME (T.V.) = 1" x IMPERVIOUS AREA T.V. = 1,866 C.F. REQUIRED DRAIN FIELD 22,793 S.F. POND BOTTOM AREA 854 S.F. DESIGN HIGH WATER AREA 1,9 S.F. TOP OF BANK AREA 2,058 S.F. SEPTIC TANK 5'x5'x4" SLAB 4'x4'x4" SLAB FOR A/C UNIT GRAVITY SANITARY SEWER SERVICE PROPOSED FENCE LINE PROPOSED 5' WIDE SIDEWALK 12.0' R 5'x5'x4" SLAB PROPOSED HANDICAP PARKING SPACE STORAGE RANGER 4'x3'x4" SLAB FOR A/C UNIT F.F. EL.=.50 36'x' BAY 14'x' BAY (OPEN) FUTURE BUILDING.0' 34.7' PROPOSED LIME ROCK W WATER WELL AREA 11,7 S.F AC. VOLUME PROVIDED 1,930 S.F. 24.0' 36.0' 14.0' PROPOSED IMPERVIOUS 2,891 SF AC. 34.0' POTABLE WATER SERVICE
10 BENCMARK #2 BENCHMARK #1 NE 40TH AVENUE ROAD DOUBLE SIDE DRAIN MITERED END SECTION INV.=M.E.G PER FDOT INDEX #273 RE-GRADE TOP AND TOP OF DITCH PER FDOT 64 LF OF 14"x23" ERCP INDEX #273 & #515 CLASS IV (TYP. AT ALL MES) A RE-GRADE TOP OF DITCH (TYP.) DOUBLE SIDE DRAIN MITERED END SECTION INV.=M.E.G PER FDOT INDEX # LF OF 14"x23" ERCP CLASS IV 64 LF OF 14"x23" ERCP CLASS IV ' RE-GRADE TOE OF DITCH (TYP.) ' E DOUBLE SIDE DRAIN MITERED END SECTION INV.=M.E.G PER FDOT INDEX # ' (TYP.). 10.0' (TYP.) 6" DEEP SWALE (4' WIDE BOTTOM) D DOUBLE SIDE DRAIN MITERED END SECTION INV.=M.E.G PER FDOT INDEX #273 STORM STRUCTURE AND PIPE TABLE S-01 MITERED END SECTION INV. =63.5 (PER FDOT INDEX #273) S-02 TYPE C DITCH BOTTOM INLET WITH TRAVERSABLE SLOT RIM EL. =.40 SLOT INV. =66. INV. =64.2 (PER FDOT INDEX #232) S-03 TYPE C DITCH BOTTOM INLET WITH TRAVERSABLE SLOT RIM EL. =.00 SLOT INV. =.42 INV. =64.58 (PER FDOT INDEX #232) P-01 P-02 LF OF 12" 1.0% SLOPE 38 LF OF 12" 1.0% SLOPE (CLASS IV) FLUME WEIR (SEE DETAIL ON THIS SHEET) SKIMMER APPROX. LIMITS OF FILL FLAT BERM (TYP.) PROPOSED POND TOP OF BANK = 65.5 BOTTOM = ' S LF OF 14"x23" ERCP CLASS IV.5 C DRAIN FIELD.5 F G MIN. 10.7' P-01 S F.F. EL.=.50 BLDG ADMIN ' CANTILEVER GATE PER FDOT INDEX P-02 S ' BOTTOM B ' CANTILEVER GATE PER FDOTINDEX 803 APPROX. LIMITS OF CUT 5' (TYP.)...Providing Solutions PROPERTY SITE INFO: AREA 62,8 S.F AC. PROPOSED IMPERVIOUS ADMIN BUILDING 2,240 SF AC. POLE BARN BUILDING 3,0 SF AC. LIME ROCK 11,351 SF AC. 5,502 SF AC. TOTAL 22,793 SF AC. PARKING (10) 18'x9' REGULAR PARKING SPACES PROVIDED (1) 18'x12' HANDICAP PARKING SPACE PROVIDED SITE INFO: AREA 11,7 S.F AC. DRAINAGE DATA: IMPERVIOUS AREA: APPROX. LIMITS OF FILL ROOT PRUNE AS NECESSARY TREATMENT VOLUME (T.V.) = 1" x IMPERVIOUS AREA T.V. = 1,866 C.F. REQUIRED 22,793 S.F. POND BOTTOM AREA 854 S.F. DESIGN HIGH WATER AREA 1,9 S.F. TOP OF BANK AREA 2,058 S.F. VOLUME PROVIDED 1,930 S.F. PROPOSED 1,087 LF OF TYPE A FENCE PER FDOT INDEX 801 (WOVEN WIRE FABRIC WITH TIMBER POSTS).20 APPROX. LIMITS OF FILL J STORAGE RANGER F.F. EL.=.50 36'x' BAY 14'x' BAY (OPEN) FUTURE BUILDING. PROPOSED IMPERVIOUS 2,891 SF AC.. I H APPROX. LIMITS OF CUT 5' LIMITS (TYP.)
11 BENCMARK #2 BENCHMARK #1 NE 40TH AVENUE ROAD PROPOSED 400 SF DRAINAGE FIELD PROPOSED EL.= ' F&I: 10,000 GALLON FIRE SUPPRESSION TANK WITH FDC CONNECTION PER NFPA 1142 F&I: 2.5" 90 BEND SIAMESE 15.2' BERM (TYP.).5 F.F. EL.=.50 BLDG ADMIN. F&I: 84 LF OF 1" PVC WATER MAIN F&I: 1" 45 BEND 40.1'...Providing Solutions ROOT PRUNE (BY CERTIFIED ARBORIST) 10.0' ' PROPOSED CLEAN OUT RIM EL.=FINIHED GRADE INV.=65.58 PROPOSED CLEAN OUTS RIM EL.=FINIHED GRADE INV.=65.82 PROPOSED CLEAN OUT RIM EL.=FINIHED GRADE INV.=66.06 F&I: 1" END CAP PROPOSED INV.=65.90 PROPOSED CLEAN OUT RIM EL.=FINIHED GRADE INV.=66.60 F&I: 144 LF OF 4" PVC SANITARY PIPE AT 1.0% SLOPE 10.0' MIN. 10.0' MIN. SEPARATION STORAGE RANGER SEE DETAIL "A-A" F&I: 1" 45 BEND F.F. EL.=.50 36'x' BAY 14'x' BAY (OPEN) FUTURE BUILDING PROPOSED WATER WELL PADS EL.=.5 (SEE ELECTRICAL PLANS FOR POWER SUPPLY) F&I: 1.5" 90 BEND W F&I: 2.5"x2.5" TEE 2.5" 90 BEND F&I: 105 LF OF 2.5" PVC WATER MAIN F&I: 2.5" 90 BEND 2.5"x1.5" REDUCER 1.5" WATER MAIN VALVE NOTE: 1. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY FOR NEAREST ELECTRICAL CONNECTION. PROPOSED CLEAN OUT RIM EL.=FINIHED GRADE F&I: 1.5" 90 BEND F&I: 190 LF OF 1.5" PVC WATER MAIN F&I: 1.5" 90 BEND PROPOSED INV.=.36 RANGER F&I: 1" 45 BEND F&I: 1.5"x1" REDUCER F&I: 1.5"x1" TEE F&I: 1" BALL VALVE DETAIL "A-A" SCALE: 1"=10' F&I: 1" TEMP. CAP
12 BENCMARK #2 BENCHMARK #1 NE 40TH AVENUE ROAD LANDSCAPE LEGEND SYMBOL TYPE TOTAL SIZE SPACING LIVE OAK 2 4" AS SHOWN SAW PALMETTO 13 3 GAL. AS SHOWN DOGWOOD 2 7 GAL. AS SHOWN.5.5 F.F. EL.=.50 BLDG ADMIN. WM WM WM STORAGE RANGER F.F. EL.=.50 36'x' BAY 14'x' BAY (OPEN) W WM WM WM WM...Providing Solutions FUTURE BUILDING SWAMP BAY 2 4" AS SHOWN EAST PALATKA HOLLY 2 4" AS SHOWN WM LONG LEAF PINE 7 7 GAL. AS SHOWN WM WM WM WM WM WM TICKSEED 80 1 GAL. AS SHOWN AREA OF SOD NOTES: 1. ALL PLANT MATERIALS ARE TO BE MINIMUM OF FLORIDA NO. ONE AS DEFINED IN GRADES AND STANDARDS REVISED, PART II, AS PUBLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. 2. ALL LANDSCAPING SHALL BE MAINTAINED PER THE STANDARDS OF ULDC 21-9.H. 3. GRASS AREAS SHALL BE SODDED. SOD PROVIDED MUST BE VIABLE, REASONABLY FREE OF WEEDS AND CAPABLE OF GROWTH AND DEVELOPMENT. IN GENERAL, SOD STRIPS SHALL BE ALIGNED WITH TIGHTLY FITTED, STAGGERED JOINTS AND NO OVERLAP OF BUTTS OR SIDES. SUBGRADE OF LAWN AREA AFTER FINISHED GRADING SHALL BE REASONABLY FREE OF STONES, STICKS, ROOTS, AND OTHER MATTER PRIOR TO THE PLACEMENT OF SOD. NEW LAWNS SHALL BE WATERED IMMEDIATELY AFTER PLANTING AND SHALL BE MAINTAINED IN A LIVING CONDITION. 4. MULCH, INCLUDING SYNTHETIC GROUND COVER, SUCH AS DECORATIVE STONE, MAY ONLY BE USED AROUND TREES AND LANDSCAPED AREAS AND MAY NOT BE USED IN LIEU OF SOD FOR LAWN AREAS. 5. ALL TREES BEING PLANTED SHALL BE 8' IN HEIGHT AT PLANTING PER ULDC A(2).
13 30.0' ADMIN. BLDG. 16.9' 5.8' 5.8' 5.7' 15.7' 24.0' 24.0' 3.7% % 0% A 2.8' 3.0% PROP. (2) 14"x23" ERCP CLASS IV B 3.0% 0% PROP. (2) 14"x23" ERCP CLASS IV 2.6% 4.2% 2% C 2% S-02 VARIES C/L 1.0% VARIES D C/L 1.0% 4.0' SWALE BOTTOM MIN. 34.2' 12.2' MES 32.8' C/L 1.7% SLOPE 6.5' MES PROP. (2) 14"x23" ERCP CLASS IV MES C/L 0.5% PROP. (2) 14"x23" ERCP CLASS IV SLOPE MES 2% 30.0' ADMIN. BLDG % VARIES ( MAX.) 24.0' C/L 1.0% 66 25' SETBACK LINE 2%.5' ADMIN. BLDG ' 66...Providing Solutions E F G CONC. 50.0' POLE BARN CONC. 50.0' 93.0' TO 30.0' DRIVE AISLE C/L VARIES SETBACK LINE (SLOPE TO R.O.W.) SWALE 6" 2 4.0' ' MIN ' POLE BARN 93.0' TO ' 30.0' DRIVE AISLE C/L 18.0' PARKING SPACE VARIES (SLOPE TO R.O.W.) SETBACK LINE SWALE 6" ' MIN ' POLE BARN ' H I J
14 ...Providing Solutions
15 ...Providing Solutions
UTILITY NOTES GENERAL CONSTRUCTION NOTES PAVING AND GRADING NOTES: TREE PROTECTION NOTES
GENERAL CONSTRUCTION NOTES PAVING AND GRADING NOTES: UTILITY NOTES PROPOSED LEGEND 66.50 66.50 GROUND SPOT ELEVATION GROUND SPOT ELEVATION (MATCH EXISTING GRADE) MATCH EXISTING GRADE MITERED END SECTION
More informationPort KC RFP NORTHLAND PARK BUILDING V
Port KC RFP NORTHLAND PARK BUILDING V 1. The RFP refers to landscaping plans. However, it does not appear that the landscaping plans were issued with the rest of the RFP. Will these be issued with an addendum?
More informationNORTH OF THE PROPERTY ON BOYETTE ROAD, PUBLISHED ELEVATION 92.29' (NAVD88).
"REUSE OF THIS DOCUMENT: THE IDEAS & DESIGNS INCORPORATED INTO THIS DRAWING ARE PROVIDED AS A PROFESSIONAL SERVICE TO THIS CLIENT AND ARE THE PROPERTY OF MPH THESE IDEAS & DESIGNS ARE NOT TO BE USED FOR
More informationEngineering Standard Minimum Checklist
Collier County Planning and Zoning Engineering Standard Minimum Checklist Engineering Stormwater, Utilities, and Engineering Transportation Engineering Stormwater Standard Minimum Checklist Please be advised:
More informationCITY OF PANAMA CITY BEACH Utilities Administration & Engineering Offices 116 South Arnold Road Panama City Beach, FL 32413
Page: 1 of 5 CITY OF PANAMA CITY BEACH Utilities Administration & Engineering Offices 116 South Arnold Road Panama City Beach, FL 32413 COMMERCIAL/RESIDENTIAL UTILITY PLAN COMPLETENESS CHECK LIST Updated
More informationWest Energy Sanitary Sewer in Columbia, SC State Project # H27-Z185-CP Prepared For. Chao & Associates, Inc.
West Energy Sanitary Sewer in Columbia, SC State Project # H27-Z1-CP Prepared For by: CA#: 398108-16 The Owner Is: 743 Greene Street Columbia, SC 29208 Project Manager Civil and Surveying DRAWING INDEX
More informationLOT GRADING GUIDELINES FOR COMMERCIAL, INDUSTRIAL, INSTITUTIONAL, MEDIUM AND HIGH DENSITY RESIDENTIAL PROPERTIES
LOT GRADING GUIDELINES FOR COMMERCIAL, INDUSTRIAL, INSTITUTIONAL, MEDIUM AND HIGH DENSITY RESIDENTIAL PROPERTIES Contents COMMERCIAL, INDUSTRIAL, INSTITUTIONAL, MEDIUM AND HIGH DENSITY... 1 RESIDENTIAL
More informationNovember 29, CITY OF PLANT CITY Purchasing Division (813)
November 29, 2018 CITY OF PLANT CITY Purchasing Division (813) 659-4270 IFB 18-014UM-LG 12-inch Water Transmission Main-Franklin St., Hancock St. and Terrace Drive West ADDENDUM No. 3 *Bidders are required
More informationGENERAL NOTES ROADWAY CONSTRUCTION RD0001-1A ISSUED:2017 REVISED: --
ROADWAY CONSTRUCTION NOTES 1. ALL RIGHT-OF-WAY OTHER THAN ROADWAY AREAS SHALL BE SODDED. ALL SLOPE STEEPER THAN 6:1 SHALL REQUIRE SODDING. THE CITY RESERVES THE RIGHT TO REQUIRE SODDING IN SPECIAL AREAS
More informationINVITATION TO BID NUMBER ITB/DA-17/18-36 REBID STORM WATER IMPROVEMENTS AT THE PLANT CITY STATE FARMERS MARKET
ADDENDUM 1 TO: FROM: RE: Vendors Salena Yarbrough INVITATION TO BID NUMBER ITB/DA-17/18-36 REBID STORM WATER IMPROVEMENTS AT THE PLANT CITY STATE FARMERS MARKET This addendum is to provide all potential
More informationBASE BID FORM FY 2015
BASE BID FORM FY 2015 STORMWATER TREATMENT AREA - BASE BID (FY2015) THE LUMP SUM (LS) PRICES FOR ITEMS 1-6 SHALL BE DONE IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND SPECIFICATIONS AND ALL APPLICABLE
More informationARCHITECT: GENERAL NOTES 1. THE CONTRACTOR SHALL REVIEW ALL DRAWINGS AND SPECIFICATIONS AND ADVISE THE ENGINEER OF ANY CONFLICTS OF REPRESENTATION BETWEEN DRAWINGS AND/OR SPECIFICATIONS PRIOR TO COMMENCING
More informationQUESTIONS & ANSWERS ITB HELEN MCCALL PARK IMPROVEMENTS
QUESTIONS & ANSWERS ITB 017-030 HELEN MCCALL PARK IMPROVEMENTS QUESTION: Site Lighting. The prints show that the existing site lighting structures are to be relocated on site. Is this the only site lighting
More informationVillage of Orland Hills COMMERCIAL Building Permit Application S. 94th Avenue, Orland Hills, IL
COMMERCIAL Building Permit Application 16033 S. 94th Avenue, Orland Hills, IL. 60487-4623 (PRINT or TYPE to complete this form only) Construction Address: {Construction Cost } Owner's Name: Applicant:
More informationADDENDUM # 3 DATE: February 16, 2018
ADDENDUM # 3 DATE: February 16, 2018 REFERENCE: Invitation for Bid No.: S-LB-18607 IFB Issue Date: January 25, 2018 Title: Stonewall Middle School Addition and Renovations Architect/Engineer: Architecture
More informationCITY OF HILSHIRE VILLAGE SWIMMING POOL PLAN SUBMITTAL CHECK LIST ADDRESS: DATE:
CITY OF HILSHIRE VILLAGE SWIMMING POOL PLAN SUBMITTAL CHECK LIST "THE FOLLOWING CHECKLIST IS ONLY A SUMMARY THAT IS PROVIDED FOR THE APPLICANT'S BENEFIT; HOWEVER, FULFILLING THE REQUIREMENTS OF THIS SUMMARY
More informationMINIMUM REQUIREMENTS FOR CONSTRUCTION PLANS, GRADING AND/OR DRAINAGE PLANS, LOW IMPACT DEVELOPMENT PLANS, AND WATER EFFICIENT LANDSCAPE PLANS
Planning and Community Preservation Department Public Works Department 232 West Sierra Madre Boulevard Sierra Madre, CA 91024 (626)355-7135 MINIMUM REQUIREMENTS FOR CONSTRUCTION PLANS, GRADING AND/OR DRAINAGE
More informationGENERAL NOTES AND CONDITIONS STORM SEWER 1. ALL EARTHWORK, GRADING AND PAVING SHALL BE PERFORMED IN ACCORDANCE WITH STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION IN ILLINOIS, STATE OF ILLINOIS
More informationINVITATION TO BID NUMBER ITB/PI-12/13-50 CONSTRUCTION OF CITRUS GERMPLASM INTRODUCTION PROGRAM BUILDING AND GREENHOUSE FOUNDATION / SLAB AND SITE WORK
ADDENDUM 3 TO: FROM: RE: Vendors Christie Hutchinson, Purchasing Director INVITATION TO BID NUMBER ITB/PI-12/13-50 CONSTRUCTION OF CITRUS GERMPLASM INTRODUCTION PROGRAM BUILDING AND GREENHOUSE FOUNDATION
More informationCONSTRUCTION SURVEY. Construction survey includes personnel, equipment, and supplies required for, but not limited to, the following:
CONSTRUCTION SURVEY PART 1 - GENERAL 1.01 SECTION INCLUDES Construction survey includes personnel, equipment, and supplies required for, but not limited to, the following: A. Construction Survey: 1. Project
More informationENGINEERING REVIEW CHECKLIST City of Mount Clemens
(To be completed by the Developer s & Submitted with ing Plans) DATE: PROJECT NAME: Site Plan Approved: Date DESIGN ENGINEERING COMPANY: ing Company Contact Information: Name: Phone: Email: Owner Contact
More informationSEMINOLE TRIBE OF FLORIDA PURCHASING DEPARTMENT RFB MABEL T FRANK WAY ROADWAY CONSTRUCTION BIG CYPRESS INDIAN RESERVATION
SEMINOLE TRIBE OF FLORIDA PURCHASING DEPARTMENT RFB MABEL T FRANK WAY ROADWAY CONSTRUCTION BIG CYPRESS INDIAN RESERVATION 6300 STIRLING ROAD HOLLYWOOD, FLORIDA 33024 ADDENDUM NUMBER THREE June 12, 2015
More informationCity of Redwood City Stormwater Pollution Prevention Program. Drainage Guidelines for Residential Development
City of Redwood City Stormwater Pollution Prevention Program Drainage Guidelines for Residential Development General Requirements A. Plot & Finished Grading Plan must be submitted with Building Permit
More informationFlorida Department of Environmental Protection Bureau of Design and Construction 3540 Thomasville Road Tallahassee, Florida 32309
Florida Department of Environmental Protection Bureau of Design and Construction 3540 Thomasville Road Tallahassee, Florida 32309 Rick Scott Governor Jennifer Carroll Lt. Governor Herschel T. Vinyard Jr.
More informationThe following is required for a complete permit submittal for each unit.
P: (847)810-3502 OR (847)810-3503/3521, F: (847)615-4383 MULTI-FAMILY OR COMMERCIAL ADDITION OR ALTERATION PERMIT REQUIREMENTS The following is required for a complete permit submittal for each unit. MULTI-FAMILY
More informationEXHIBIT A FEE SCHEDULE
EXHIBIT A FEE SCHEDULE PERMIT FEE WORKSHEET INSTRUCTIONS: Each application for a new permit or change in status shall be accompanied by the appropriate fee as indicated below. NO PERMIT APPLICATION WILL
More informationWIBLE BARBER Architects
WIBLE BARBER Architects Billingsley School Bleacher Replacement 2246 County Road 77 / Billingsley, Alabama 36006 BC PROJECT NO: 2017499 WBA PROJECT NO: 170901 ADDENDUM NO. 2 GENERAL: November 28, 2017
More informationCITY OF ELKO BID TABULATION FOR Sports Complex
CITY OF ELKO BID TABULATION FOR Sports Complex 2017-2018 NAME Granite Construction Great Basin Engineering Contractors Road & Highway Builders CLEARING EARTHWORK 1 33701200 Mobilization @ Per Lump Sum
More informationA NEW PRE-K BUILDING FOR BIG SPRING LAKE KINDERGARTEN SCHOOL FOR THE ALBERTVILLE CITY BOARD OF EDUCATION ALBERTVILLE, ALABAMA
McKee and Associates Architecture and Interior Design Addendum No. FOUR Date: 09.24.18 Project: A NEW PRE-K BUILDING FOR BIG SPRING LAKE KINDERGARTEN SCHOOL FOR THE ALBERTVILLE CITY BOARD OF EDUCATION
More informationZONING CLEARANCE PLAN REVIEW CHECKLIST. Based on the Revised Town of Carefree Zoning Ordinance
ZONING CLEARANCE PLAN REVIEW CHECKLIST Based on the Revised Town of Carefree Zoning Ordinance Date: Applicant: Permit Number: Reviewer: Address: Lot & Subdivision: Zoning District: New SRF: Addn/Remodel:
More informationADDENDUM NO. 5. Except as hereinafter specified, the work shall be in accordance with the drawings and specifications.
ADDENDUM NO. 5 ITB-CD-CME-16-10 Southern Well Field Expansion: Equip 5 Wells and New Raw Water Main Phase 2 ISSUE DATE: August 22, 2016 DUE DATE: August 25, 2016 @ 2:00 p.m. SUBJECT: Addendum No. 5 INTENT:
More informationCommercial Submittal Packet
Commercial Submittal Packet City of Pepper Pike Building Department 28000 Shaker Boulevard Pepper Pike, Ohio 44124 Phone: (216) 896-6134 Fax: (216) 831-6525 www.pepperpike.org Submitting for the Architectural
More informationPERMIT APPLICATION REQUIREMENTS NEW SINGLE FAMILY DWELLING
PERMIT APPLICATION REQUIREMENTS NEW SINGLE FAMILY DWELLING CODES USED: CURRENT ADOPTED FLORIDA BUILDING CODE AND NEC MANDATORY DOCUMENTS: 1. COMPLETED NEW SINGLE FAMILY PERMIT APPLICATION PACKET. ALL APPLICABLE
More informationCONSTRUCTION PLAN CHECKLIST
CONSTRUCTION PLAN CHECKLIST The design engineer is responsible for ensuring that plans submitted for city review are in accordance with this checklist. It is requested that the executed checklist be submitted
More informationLOT GRADING. LOT GRADING REQUIREMENTS The following lot grading requirements came into effect on May 1, 2007:
LOT GRADING DEFINITION Lot grading is the reshaping or sloping of the land in such a way that surface drainage from rain runoff is directed away from the buildings and is controlled in a manner that eliminates
More informationBUREAU Joe Iuviene, AIA January 20, 2017
architectural BUREAU Joe Iuviene, AIA January 20, 2017 Alterations & Additions NEW TOWN HALL for TOWN OF AUSTERLITZ 816 State Route 203, Spencertown, New York 12165 ADDENDUM NO. 1 This addendum amends
More informationCONSTRUCTION PLANS FOR ENTERPRISE RENTAL CAR
CONSTRUCTION PLANS FOR VICINITY MAP (NOT TO SCALE) DEVELOPER/OWNER: CHRISTOPHER SLOVAN ENTERPRISE HOLDINGS, INC. 284 MALLORY STATION RD, SUITE 120 FRANKLIN, TN 37067 PH: 615-309-9621 DAVIDSON CO., TENNESSSEE
More informationT a b l e o f C o n t e n t s
C i t y o f G l a d s t o n e P u b l i c W o r k s D e s i g n S t a n d a r d s T a b l e o f C o n t e n t s SECTION THREE SANITARY SEWER REQUIREMENTS... 1 3.0000 SANITARY SEWERS... 1 3.0010 General
More informationPART II - SURVEYING AND GRADING CRITERIA
PART II - SURVEYING AND GRADING CRITERIA A. Surveying Procedures 1. Unless a temporary benchmark is approved in advance by the City Engineer, all submitted civil plans, including but not limited to grading,
More information36 JASPER THPMAS ROAD CRAWFORDVILLE, FL.
N ARRAN RD. N US 319 CRAWFORDVILLE HWY SR 61 SHADEVILLE RD. WAKULLA HARVEY MILL ROAD US 319 PREBLE-RISH INC CIVIL SURVEYING SITE PLANNING 36 JASPER THPMAS ROAD CRAWFORDVILLE, FL. 32327 GENERAL NOTES: 1.
More informationAppendix K: Soil Erosion and Sedimentation Control Plan Check List
Appendix K: Soil Erosion and Sedimentation Control Plan Check List Drain Commissioner 46 February 2005 SOIL EROSION AND SEDIMENTATION CONTROL PLAN CHECK LIST Items listed below must be clearly depicted
More informationCOMMUNITY PLAZA WAY ASPHALT PAVEMENT OVERLAY ADDENDUM NO.1 UPPER SKAGIT INDIAN TRIBE PAGE 1
UPPER SKAGIT INDIAN TRIBE COMMUNITY PLAZA WAY ASPHALT PAVEMENT OVERLAY ADDENDUM NO. 1 (7 pages total) Issue Date: May 11, 2016 General: Recitations of each and every section of the bid documents impacted
More informationHURON PUBLIC WORKS BUILDING HURON, SOUTH DAKOTA BID NO R
HURON PUBLIC WORKS BUILDING HURON, SOUTH DAKOTA BID NO. 2017-26R Stone Group Architects Project No. 1731 ADDENDUM DATE: September 14, 2017 BID DATE: September 18, 2017 2:00 P.M. C.S.T. SCOPE OF THIS ADDENDUM:
More informationLOT GRADING GUIDELINES FOR LOW DENSITY RESIDENTIAL PROPERTIES
LOT GRADING GUIDELINES FOR LOW DENSITY RESIDENTIAL PROPERTIES Contents LOT GRADING GUIDELINES... 3 LOW DENSITY RESIDENTIAL PROPERTIES... 3 Introduction... 3 Definitions:... 3 Purpose... 3 LOT GRADING APPROVAL
More informationHITT STREET UNIVERSITY PROJECT #: CP REFER TO CP PLANS FOR ELECTRICAL DUCTBANK IN HITT STREET INSTALL:
N 1133521.33 E 1689742.43 STA: 10+53.07 INSTALL: 2-10" 90 BENDS CONNECT TO MIDDLEBUSH HALL INTERIOR PLANT PLUMBING MIDDLEBUSH HALL HW1 HWS HWR 10+00 FREDRICK APARTMENTS FINE ARTS INSTALL 422 LF 10" HWS
More informationINSPECTION TIMING CHECKLIST FOR RESIDENTIAL FRAME BUILDING PRIOR TO INSPECTION REQUEST
Village of Vernon Hills Community Development Department - Building Division 290 Evergreen Drive, Vernon Hills, IL 60061 Phone 847-367-3704 - Fax 847-367-2541 - http://www.vernonhills.org INSPECTION TIMING
More informationSTATE UNIVERSITY CONSTRUCTION FUND
DIRECTIVE 2-1 Issue date: September 2012 1. General SITEWORK OVERVIEW This Directive outlines the Fund s requirements for the Consultant relative to the development, design and presentation of documents
More informationPROPOSED SEGMENTAL RETAINING WALLS ARGONAUT RETAIL VILLAGE - PHASE I PENSACOLA, FLORIDA
CERTIFICATE AUTHORIZATION: 2 24 ANCHOR WALL ENGINEERING, LLC MATERIAL NOTES. Concrete Retaining Wall Units: "Anchor Diamond Pro Retaining Wall Units" as manufactured by Block USA under license from Anchor
More informationSITE PLAN NOTES 1. MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED FROM VIEW WITH HEDGE.
SITE PLAN NOTES FLOOD STATEMENT BY 1. MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED FROM VIEW WITH HEDGE. 2. DUMPSTER SCREENING SHALL BE OF SIMILAR COLOR, MATERIAL, AND DESIGN AS THE PRIMARY STRUCTURE.
More informationIndex. Composition and Order of Plan Set. Utility Plan... 5
City of Des Plaines Public Works and Engineering Department Revised-October 5, 2012 Index Composition and Order of Plan Set Title Page Number Cover Sheet... 1 Requirements for Site Development... 2 Grading
More informationCounty of Georgetown, South Carolina
County of Georgetown, South Carolina 129 Screven Street, Suite 239 Georgetown, SC 29440-3641 Post Office Box 421270, Georgetown, SC 29442-4200 (843)545-3082 Fax (843)545-3500 purch@gtcounty.org ADDENDUM
More informationCUSTOM HOMES, ADDITIONS TAYLOR BUILDING & COMMERCIAL DESIGNS 63 KENSINGTON ROAD, SAN ANSELMO, CALIFORNIA SPIRIT LIVING GROUP APN
SPIRIT LIVING GROUP 63 KENSINGTON ROAD, SAN ANSELMO, CALIFORNIA 100 HELENS LANE MILL VALLEY, CA 94941 415 388 9585 F 415 388 0412 CPD ENGINEERS / SURVEYORS / PLANNERS 1646 N CALIFORNIA BLVD SUITE 400 WALNUT
More informationSUMMIT COUNTY PLANNING AND ENGINEERING DEPARTMENT SINGLE-FAMILY/DUPLEX BUILDING PERMIT / GRADING AND EXCAVATION PERMITTING INFORMATION PACKET
SUMMIT COUNTY PLANNING AND ENGINEERING DEPARTMENT SINGLE-FAMILY/DUPLEX BUILDING PERMIT / GRADING AND EXCAVATION PERMITTING INFORMATION PACKET GENERAL INFORMATION The following information explains how
More informationKANKAKEE COUNTY PLANNING DEPARTMENT APPLICATION FOR CLASS I & II GRADING AND DRAINAGE/STOMRWATER PERMIT APPLICATION
KANKAKEE COUNTY PLANNING DEPARTMENT APPLICATION FOR CLASS I & II GRADING AND DRAINAGE/STOMRWATER PERMIT APPLICATION Michael J. Van Mill, AICP Planning Director 189 East Court Street Kankakee, IL 60901
More informationThis is only a general checklist; please refer to the CVWD Development Design Manual (DDM) for all requirements and regulations.
COACHELLA VALLEY WATER DISTRICT DOMESTIC WATER CHECKLIST Tract/Parcel No: Project Common Name: Developer: Engineer: Engineer Signature: Date: Phone: Phone: Print: This is only a general checklist; please
More informationRESIDENTIAL ADDITION OR ALTERATION PERMIT REQUIREMENTS
P: (847)810-3502 OR (847)810-3503/3521, F: (847)615-4383 RESIDENTIAL ADDITION OR ALTERATION PERMIT REQUIREMENTS The following is required for a complete permit submittal. RESIDENTIAL BUILDING PERMIT, ELECTRIC
More informationAMERA COURT RESIDENTIAL SUBDIVISION
Prepared By: LOCATION MAP N.T.S. PROJECT SITE N 000 Gulf to Bay Boulevard, Suite 0 Clearwater, FL Tel. ()- AMERA COURT RESIDENTIAL SUBDIVISION Grant Street Dunedin, Florida FEMA MAP PANEL NO. 0C-00-C FLOOD
More informationIMPROVEMENT PLANS FOR CITY OF RIO VISTA CONDITIONAL USE PERMIT NO
IMPROVEMENT PLANS FOR CITY OF RIO VISTA CONDITIONAL USE PERMIT NO. 2016-002 AND LIFORNIA 94571 REVISIONS VICINITY MAP No. Description NTS CONTACTS SHEET INDEX SHEET NO. SITE MAP 1"=50' COVER SHEET R MLP
More informationCONDITIONS EXISTING EXISTING CONDITIONS SURVEY PROVIDED BY EGAN, FIELD & NOWAK ON FEBRUARY 20, PRELIMINARY - NOT FOR CONSTRUCTION
K:\TWC_LDEV\\ABRA\Maple Grove, \ Design\CAD\PlanSheets\C- CONDITIONS.dwg April 4, 018 - :44pm 40 0 8 CONDITIONS SURVEY PROVIDED EGAN, FIELD & NOWAK ON FEBRUARY 0, 018. LIMITS OF CONSTRUCTION OVERHEAD POWER
More informationMETATEK POWER HOUSE CONSTRUCTION BUILDER S GUIDE CHECKLIST
BUILDER S GUIDE & CHECKLIST 1 Table of Contents OVERVIEW... 2 CONSTRUCTION GUIDELINES... 2 DO NOT MODIFY LIST... 3 OPTIONAL LIST... 3 BUILDING DRAWINGS... 4 CHECKLIST... 4 MATERIALS LIST... 15 MATERIALS
More informationValley Forge and NC Hwy 86
85 86 AVAILABLE FOR PRE-LEASE Valley Forge and NC Hwy 86 Partnership. Performance. Features Type Building Size Available sf Rental Rate Delivery Date Location Class A Office Building 25,000 sf 0,000 sf
More informationProject Location: Various, Anywhere, PA Bid Date: 7/16/ Rock Construction Entrance
To: Project Name: Bidding Company Site Work Project Contact: Address: Various Phone: Fax: Bid Number: Project Location: Various, Anywhere, PA Bid Date: 7/16/2014 Clarifications: This takeoff does not include
More informationProperty Address: Builder: Phone #: Address:
SEPTIC NEW RESIDENTIAL CONSTRUCTION RESIDENTIAL REMODEL COMMERCIAL REMODEL NEW COMMERCIAL PLAN REVIEW RESPONSE Property Address: Builder: #: Address: REQUIRED DOCUMENTATION FOR SUBMITTALS ORDINANCE SECTION
More informationChapter 3 Dispersion BMPs
Chapter 3 Dispersion BMPs 3.1 BMP L611 Concentrated Flow Dispersion 3.1.1 Purpose and Definition Dispersion of concentrated flows from driveways or other pavement through a vegetated pervious area attenuates
More informationHYDROLOGIC RESTORATION OF THE CASH CREEK BASIN IN TATE'S HELL STATE FOREST
HYDROLOGIC RESTORATION OF THE CASH CREEK BASIN IN TATE'S HELL STATE FOREST CONSTRUCTION PLAN BID SET PREPARED FOR: LOCATION MAP CARRABELLE US ROUTE 319/98 EASTPOINT Prepared By Plan Design Enable CORPORATE
More informationLANDSCAPE RETAINING WALLS
SUDAS Standard Specifications Division 9 - Site Work and Landscaping Section 9070 - Landscape Retaining Walls LANDSCAPE RETAINING WALLS PART - GENERAL.0 SECTION INCLUDES A. Modular Block Retaining Walls
More informationCOMMERCIAL PROJECT PLAN REVIEW PROCESS
COMMERCIAL PROJECT PLAN REVIEW PROCESS Complete construction documents, which contain all of the required information will speed the plan review process. The following checklist establishes minimum guidelines
More informationA New Municipal Building for Limerick Township
A New Municipal Building for Limerick Township DOCUMENT 00 9001 - ADDENDUM NUMBER 01 December 9, 2016 Re: A New Municipal Building for Limerick Township From: Kelly Clough Bucher & Associates, Inc. 8 East
More informationIf a new residence s electrical service is not located within 200 feet of existing
Primary Line Extensions CHAPTER 4 If a new residence s electrical service is not located within 200 feet of existing primary electrical facilities, a primary line extension is required to place a close
More informationADDENDUM # 3 CITY OF CAPE CANAVERAL BID # CITY OF CAPE CANAVERAL WWTP IMPROVEMENTS FOR OXIDATION DITCH REHABILITATION June 24, 2016
ADDENDUM # CITY OF CAPE CANAVERAL BID #- CITY OF CAPE CANAVERAL WWTP IMPROVEMENTS FOR OXIDATION DITCH REHABILITATION June, All contents of this addendum shall be incorporated into the solicitation documents
More informationRFI REPLY. Project: Palm Coast Readiness Center Date: 07/22/16 Flagler County, Florida Comm. No.: 09005
Project: Palm Coast Readiness Center Date: 07/22/16 Flagler County, Florida Comm. No.: 09005 To: All Bidding General Contractors Fax Email U.S. Mail Attn. Messenger We are sending the following: Quick
More informationCONSTRUCTION SPECIFICATION FOR SITE RESTORATION FOR UNDERGROUND UTILITIES
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 507 JULY 1991 CONSTRUCTION SPECIFICATION FOR SITE RESTORATION FOR UNDERGROUND UTILITIES 507.01 SCOPE 507.02 REFERENCES 507.03 Not Used 507.04 Not Used
More information62 POTOMAC STREET WEST ROXBURY, MA 02132
62 POTOMAC STREET SET P R O J E C T T E A M COVER 1. ALL WORK SHALL BE IN COMPLIANCE WITH ALL APPLICABLE LOCALS BUILDING CODES AND REGULATIONS. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR S REQUIRED FOR CONSTRUCTION
More informationDevelopment Advisory - 40 March 21, 2018
Development Advisory - 40 March 21, 2018 Single Family Lot Grading Requirement The City of Chesapeake has policies that distribute the responsibility for lot grading between the developer and the builder.
More informationGlades County MOBILE HOME INSTALLATION PLAN REVIEW WORK BOOK
Glades County MOBILE HOME INSTALLATION PLAN REVIEW WORK BOOK COMMUNITY DEVELOPMENT DEPARTMENT Permit # Home Owner lnstallation Site Address Name of Licensed lnstaller License Number Installation Decal
More informationADDENDUM NO. 1. VILLAGE OF VERSAILLES North West Street Extension March 19, 2018
ADDENDUM NO. 1 VILLAGE OF VERSAILLES North West Street Extension March 19, 2018 To: Planholders From: Mote & Associates, Inc. Phone: (937) 548-7511 214 West Fourth Street Fax: (937) 548-7484 Greenville,
More informationCIRCLE K SUB-CONTRACTOR BID FORM
CIRCLE K SUB-CONTRACTOR BID FORM Store No: 3308 Address: 8985 Will Clayton Pkwy Date: Bid Due September 17, 2014 Sub Contractor: Trade CONSTRUCTION TAX Construction Tax EXCAVATION / DIRT WORK Cut / Fill
More informationLast Updated March 15, 2016
CASS COUNTY, MISSOURI BUILDING CODES, ENVIRONMENTAL HEALTH AND ZONING DEPARTMENT 30508 S. West Outer Road, Harrisonville, MO 64701 P- (816) 380-8134 F- (816) 380-8130 Last Updated March 15, 2016 Information
More informationBID ADDENDUM #1 September 24, 2010
BID ADDENDUM #1 September 24, 2010 To: Prospective Bidders/Planholders For: Science 1 Seismic Retrofit & Renovation California State University Stanislaus One University Circle, Turlock, CA 95382 Bid /
More informationPUBLIC WORKS STANDARD DETAILS
PUBLIC WORKS STANDARD DETAILS SUBSTANTIAL EFFORT HAS BEEN MADE TO ENSURE THE INFORMATION CONTAINED IN THESE STANDARDS IS ACCURATE. HOWEVER, THE CITY OF BRADENTON BEACH CANNOT ACCEPT RESPONSIBILITY FOR
More information30' REQ'D FRONT SETBACK STORAGE 640.0' DETACHED GARAGE SLAB AT DOOR ' PAD GRADE ' (E) STORM DRAIN UNDERGROUND GAS, ELEC, TEL, TV 18'-1"
PROJECT DATA PROJECT ADDRESS:, SARATOGA, CA PROJECT DESCRIPTION: NEW CARETAKER'S AND NEW DETACHED OWNER: ALBERT : 537--1 LOT SIZE: 15,3.86 SF 3.5 ACRES ALLOWABLE FLOOR AREA: 6 SF (ASSUME LOT IS OVER 3%
More informationCITY OF SCHERTZ TEXAS ENGINEERING AND PUBLIC WORKS
TEXAS STANDARD CONSTRUCTION NOTES DRWN. BY: DSGN. BY: KJW 1 of 2 *Place geotextile fabric as a permeable seperator to prevent mixing of coarse aggregate and underlying soil. (as needed). 1. GEOTEXTILE
More informationENGINEERING PERMIT APPLICATION SUBMITTAL CHECKLIST SINGLE FAMILY RESIDENTIAL STRUCTURE
ENGINEERING PERMIT APPLICATION SUBMITTAL CHECKLIST SINGLE FAMILY RESIDENTIAL STRUCTURE Refer to the Town s Code Of Ordinances for more information on a requirement specified in this checklist. The Code
More informationPERMIT APPLICATION REQUIREMENTS NEW COMMERCIAL BUILDING/CONSTRUCTION CODES USED: CURRENT ADOPTED FLORIDA BUILDING CODE AND NEC
PERMIT APPLICATION REQUIREMENTS MANDATORY DOCUMENTS: NEW COMMERCIAL BUILDING/CONSTRUCTION CODES USED: CURRENT ADOPTED FLORIDA BUILDING CODE AND NEC 1. COMPLETED NEW COMMERCIAL or MULTIFAMILY PERMIT APPLICATION
More informationBeaumont Lot Grading Guidelines
Beaumont Lot Grading Guidelines Updated: 2019-01-14 CONTENTS LOT GRADING OVERVIEW... 3 INTRODUCTION... 3 PURPOSE... 3 DEFINITIONS... 3 LOT GRADING REQUIREMENTS... 3 DESIGN GRADES AND EXISTING GRADES...
More informationE.P. CLARKE ELEMENTARY SCHOOL SITE IMPROVEMENTS
o:\projects\2016\ ep clarke elementary circulation\cad\_civil\ TL.dwg, 1, /5/2016 2:5:02 PM, mle, 1:1 NOTES: Sheet List Table SHT NO. DESCRIPTION COUNTY KEY OFFICIALS LOCAL UTILITIES CALL MISS DIG PROJECT
More informationHousing Authority of Utah County
Legend Springville Site Vicinity Map (not to scale) Planning Department 110 South Main Street Phone (801) 491-7861 Fax (801) 489-2716 Community Development Director - J Fred Aegerter Public Works Department
More informationBARTOW COUNTY RESIDENTIAL DRAINAGE PLAN or RDP
BARTOW COUNTY RESIDENTIAL DRAINAGE PLAN or RDP A Residential Drainage Plan accepted by the Engineering Department shall be required prior to issuance of a Building Permit on those lots subject to periodic
More informationREQUIRED INFORMATION Please check the following boxes that apply to your lot or parcel and complete the other requested information.
MARTIN COUNTY EXCAVATION AND FILL PERMIT APPLICATION This application to be used only for excavating or filling activities not associated with a building permit or development review and for projects requiring
More informationCommercial Remodel Permit
Commercial Remodel Permit Zoning requirements Staff recommends always verifying the zoning requirements for your project before deciding to build. Warrensburg has eleven separate zoning districts, each
More informationGRADING & DRAINAGE PERMIT SOIL EROSION AND SEDIMENTATION CONTROL PERMIT PROGRAM OVERVIEW
GRADING & DRAINAGE PERMIT SOIL EROSION AND SEDIMENTATION CONTROL PERMIT PROGRAM OVERVIEW Chapter 8 Building and Building Regulations, Article XIII Grading and Drainage and Article XV Soil Erosion and Sedimentation
More information(ITEMS APPLICABLE TO THIS PROJECT MARKED WITH "X")
Development Services Planning Division 150 N. Lakeshore Drive Ocoee, FL 34761 Phone: 407.905.3157 Fax: 407.905.3158 Received Date Office Use Only (ITEMS APPLICABLE TO THIS PROJECT MARKED WITH "X") DATE:
More informationEngineering Division 701 Laurel Street Menlo Park, CA Phone: (650) Fax: (650)
Engineering Division 701 Laurel Street Menlo Park, CA 94025 Phone: (650) 330-6740 Fax: (650) 327-5497 GRADING AND DRAINAGE GUIDELINES FOR SINGLE FAMILY HOME PROJECTS It is the responsibility of the property
More informationCITY OF ASTORIA PUBLIC WORKS ENGINEERING DIVISION ENGINEERING DESIGN STANDARDS FOR IN-FILL DEVELOPMENT
CITY OF ASTORIA PUBLIC WORKS ENGINEERING DIVISION ENGINEERING DESIGN STANDARDS FOR IN-FILL DEVELOPMENT Adopted by City Council: May 21, 2007 X:\General Eng\DESIGN STANDARDS\Engineering Design Standards
More informationCity of Roanoke. Commercial Permit Submittal Guidelines
City of Roanoke Commercial Permit Submittal Guidelines These guidelines are for information purposes only. The contractor is obligated to comply with all adopted codes and ordinances BUILDING INSPECTIONS
More informationCITY OF ALBANY Public Works Department ADDENDUM #1 ST CROCKER LANE RECONSTRUCTION
CITY OF ALBANY Public Works Department ADDENDUM # ST-6-02 CROCKER LANE RECONSTRUCTION In order to clarify the intent of the Specifications and Drawings, the following provisions are provided and shall
More informationCITY OF URBANA CLASS 2 EROSION CONTROL PERMIT STANDARD DETAILS
CITY OF URBANA CLASS 2 EROSION CONTROL PERMIT STANDARD DETAILS CLASS 2 EROSION CONTROL PERMIT STANDARDS TABLE OF CONTENTS EROSION CONTROL PRACTICES FLOW CHART 1 EROSION CONTROL PERMIT FORM 2 EXAMPLE EROSION
More informationSECTION CONSTRUCTION SERVICES
SECTION 01100 CONSTRUCTION SERVICES PART 1 GENERAL 1.01 - Section Includes A. Mobilization. B. Construction Surveys. C. Record Documents. 1.02 Description Of Work A. Mobilization: includes the preparatory
More informationAPPENDIX E APPLICATIONS
APPENDIX E APPLICATIONS Schedule of Fees ACC Meeting Calendar Foundation Survey & As Built Plan Checklist Application for New Construction Landscape Review Submittal Sheet Elevation Verification/Foundation
More informationReceived by:* Date Received:* Zoning Approval:* Date:* PERMIT#:* *ZONING: *SETBACKS: FRONT ft/ SIDE ft/ REAR ft *FLOOD ZONE:
HENDRY COUNTY BUILDING, LICENSING & CODE ENFORCEMENT POST OFFICE BOX 2340 * 640 SOUTH MAIN STREET * LABELLE, FLORIDA 33975 * (863) 675-5245 * FAX: (863) 674-4194 1100 OLYMPIA ST CLEWISTON, FLORIDA 33440
More information