Post Office Box 867, Dunedin Florida Tel: (727) Fax: (727)

Size: px
Start display at page:

Download "Post Office Box 867, Dunedin Florida Tel: (727) Fax: (727)"

Transcription

1 Post Office Box 867, Dunedin Florida Tel: (77) Fax: (77) Property Inspected for: 0 Property Address: 0 Tampa, Florida Date of inspection: Thursday, October 0, 03

2 Inspection Information Sheet Inspection Information: Date of Inspection: Thursday, October 0, 03 at 9:30am Inspection Type: Full residential Contact Information: Client (s): Cell Phone: Property Address: Tampa, Florida People Present: N/A Billing Address: Alternative Phone: Selling Agent: Cell Phone: Listing Agent: Company: Work Phone: Cell Phone: Building Information: Building type: Construction type: Foundation type: Single Family Frame Masonry Number of stories: Residence status: Out-buildings: Occupied Detached Garage Approximate building orientation: Recent weather conditions: Current temperature: Main water shut-off valve at: Main electrical breaker at: Main gas shut off: West Sunny & Dry 80 Meter Exterior South wall Exterior rear wall Pool: Sea Wall: Dock: Guest apt: Yes Approximate age of building: Approximate total square footage: Approximate living area: Crawl space square footage: years Billing Information: Standard Fee: Square Footage Fee: Crawl Space Fee: Guest Apartment: $85 $ $85 $75 Insurance forms 4 Point: Wind Mitigation: $75 $00 Core Inspection: $456 Additional Services: $75 Sub Total: $63 Adjustments: TOTAL DUE: $63

3 Report Summary This summary should not be used in lieu of reading and understanding the entire report as the report contains information and limitations pertinent to the summary. The items listed as needing repair, replacement, servicing, or further evaluation, may not necessarily be contractual in nature. This report should be read in conjunction with your contract to determine which items are contractual. Any areas of uncertainty should be clarified by consulting your real estate agent or attorney. Post Office Box 867, Dunedin FL Tel: (77) Fax: (77) STRUCTURAL Several areas of badly rotted, compressed and missing bottom plate were seen inside the garage as a result of water intrusion around the base of the walls. This has caused some movement of the structure in conjunction with several other areas of heavy termite damage that were seen to wall and floor framing. I recommend having a framing contractor or structural specialist fully evaluate the garage structure at this time and make all needed repairs. EXTERIOR Decay was noted at the front porch roof system at the rafter against the wall of the home to the right side of the door. Lack of appropriate flashings at these roof return details is allowing water intrusion behind the siding and needs to be reworked at this time. The rear bedroom South wall window is in particularly poor condition on the exterior and should be carefully reworked at this time. Decay at the NW window next to the carport needs to be repaired. Decay at the base of the garage door frames and damaged trim around the garage doors and upper-level windows needs to be repaired. Loose soffit on the West side of the garage needs to be repaired. Damaged roof decking seen at soffit area on the north of the garage indicates roof leakage and needs to be repaired in conjunction with the roof. The garage exterior staircase is heavily deteriorated and is not safe. The entire staircase and upper-level landing should be considered for being rebuilt at this time for safety. The garage lower rear wall North window sill is badly rotted and needs to be replaced. There is a section of split siding on the upper front wall of the garage that should be sealed to prevent water intrusion. Damage to trim on the rear header beam over the carport was noted and should be repaired. It would be wise to open this trim to be able to inspect the structural beam. GROUNDS Trim all shrubbery and tree contact away from the building and roof at this time. The main electric service wires going to the house run through thick shrubbery and trees; trimming should be performed at this time. This may be a service offered for free by the electric company.

4 ROOF 3 Downspouts are missing at the carport gutter system and need to be installed. Evidence of leakage at the North edge of the garage roof was noted and needs to be addressed. Evidence of leakage over the NW section of the garage roof was noted. Tree contact and heavy tree debris buildup on this roof also needs to be addressed. I recommend having a roofer carefully inspect and repair the garage roof as needed at this time. INTERIOR 3 Badly damaged ceiling in the apartment appears to be the result of active roof leakage. Repairs are needed at this time. The main house front doorknob is faulty and the door does not latch shut properly. This should be adjusted at this time for normal operation. Several very heavily damaged floorboards in the rear bedroom were found and they should be replaced at this time. PLUMBING The main house water heater gas line requires a drip leg. The main house water heater temperature and pressure relief valve requires an appropriate extension pipe. The vent on top of the main house water heater is improperly installed and needs to be corrected by a licensed plumber for safety. The apartment toilet leaks badly when flushed and needs to be corrected. The apartment shower handle leaks and also needs to be corrected. The apartment bathroom sink is badly cracked and needs to be replaced. A section of corrugated flexible pipe has been used as a horizontal drain under the main house kitchen sink. This type of piping traps debris and should be replaced with appropriate drain pipe at this time. The main house toilet is very loose and needs to be properly secured on the floor. The main house kitchen sink faucet stem leaks and should be corrected. ELECTRICAL Missing knock-out at the garage main electric panel needs to be replaced. The main breaker for the garage service is 00 A. This is oversized considering the size of the main service wire and should be corrected by an electrician. Many exposed wires in the garage should be protected behind paneling or in conduit. The AC condenser unit disconnect box is missing a knock-out on the side and should be corrected. This box is starting to rust aggressively and should be considered for replacement soon. Active knob and tube wiring was found in the apartment. Have an electrician replace all such wiring as needed at this time.

5 APPLIANCES The apartment refrigerator did not appear to initiate properly. The apartment kitchen ceiling fan did not turn on. HVAC Several of the duct boxes in the attic over ceiling registers are loose and improperly secured and should be secured and sealed at this time. All quotes and work should be carried out by licensed professionals. Inspector: James Booth 0/0/03 FL License: HI 877 signed date

6 STRUCTURAL Foundation type: Sub-structure type: Crawl Space: Elevated masonry Support beams Joists Limited access due tolow clearance Crawl space entrance at: Crawl space screened: Visible evidence of: South side Yes, Wire Wood Destroying Organis Structural elements of the building are inspected visually with no destructive testing performed. Both frame and masonry buildings can develop settlement cracking to interior finishes and exterior hard surfaces. Only abnormal or unusual cracks will be commented on in detail. Related Notes: The home was found to be basically sound with no visible signs of significant or abnormal settlement over the years. Obviously, the home has shifted, as was noted by slope to the interior floors, cracks to plaster walls and ceilings and some cracking of the foundation stem wall at the SW corner of the home. Work has been performed under the structure within the past 0 years and what could be seen inspected well. The under floor area offered quite limited access and visibility due to very low clearance under the house. I was unable to access the majority of the eastern half of the structure. All of the structural repairs that have been performed appear to have been executed by removing the interior floors. There were no structural issues noted with the home that require immediate attention. Maintenance Items: The garage has settled and shifted quite noticeably over the years. The structure appears to be generally leaning towards the South. The movement appears to be the result of typical settlement of the original concrete slab, water damage to the wall framing bottom plate, termite damage and the orientation of the floor joists for the second level providing little rigidity. The lean is quite noticeable and is something that should be carefully monitored in the future with the anticipation that adjustments and bracing may be required at some point. Several conditions exist at this time that hurt the overall integrity of this building and require repair - see below. Immediate Repairs: Several areas of badly rotted, compressed and missing bottom plate were seen inside the garage as a result of water intrusion around the base of the walls. This has caused some movement of the structure in conjunction with several other areas of heavy termite damage that were seen to wall and floor framing. I recommend having a framing contractor or structural specialist fully evaluate the garage structure at this time and make all needed repairs.

7 Structural Figures Front elevation Right side elevation 3 4 Rear elevation Left side elevation

8 Structural Figures 5 6 Under floor view Garage view showing lean 7 8 Cracking and settlement to the garage slab Rotted away bottom plate at garage wall framing

9 EXTERIOR Wall type: Primary Surface: Secondary Surface: Soffits: Fascias: Trim: Doors: Chimney: Frame Aluminum Metal Metal Wood Wood Brick Columns: Stairs: Handrails: Attached structures: Deck/Balcony supports visible: Garage type: Door opener tested: Limited accessibility: Wood None None Deck(s) Yes Detached N/A No Exposed wood is prone to water and termite damage and should be sealed and painted regularly. Keep all wood trim and siding away from the grade and mulch. Maintain caulking around windows, doors, cracks and joints. Related Notes: The exterior of the home does not appear to have been particularly well-maintained in several years and a number of deficiencies related to deferred maintenance were found. Generally speaking, the building envelope is intact but several key observations and recommendations for improvements are detailed below. The exterior of the garage is in much the same condition, or slightly worse than the main house, barring the issues noted on the STRUCTURAL page. Maintenance Items: It is very important to keep the intersection of the front porch and front wall of the home well sealed to prevent water intrusion; improvements should be made to this area at this time. Additionally, evidence suggests that this front porch slab has moved relatively recently. Cracking should be sealed and the porch slab should be painted to help reduce the likelihood of water intrusion and erosion underneath the slab. All exterior wooden trim was found to be in poor condition with painting and caulking improvements needed at this time. Several areas of wood repair or replacement will be needed, the most significant areas are detailed below. Paint on the exterior of the home is generally weathered. While the aluminum siding material does not necessarily need to be painted and would simply benefit from being cleaned, there are many areas of caulking improvements that should be performed at wall penetrations, windows and other joints in the siding. As a result of the important waterproofing that should be performed, I recommend considering fully cleaning, caulking, and painting both structures at this time. Open areas of siding and soffit were seen around various trim and rafter-to-wall intersections. These poorly finished areas of detail will be prone to water penetration behind the siding and also animal intrusion into the walls and attic. It would be wise to have all such areas carefully sealed in the near future. I recommend sealing the bottom of the AC line chase to help reduce the likelihood of animals from getting into the attic.

10 Immediate Repairs: Decay was noted at the front porch roof system at the rafter against the wall of the home to the right side of the door. Lack of appropriate flashings at these roof return details is allowing water intrusion behind the siding and needs to be reworked at this time. The rear bedroom South wall window is in particularly poor condition on the exterior and should be carefully reworked at this time. Decay at the NW window next to the carport needs to be repaired. Decay at the base of the garage door frames and damaged trim around the garage doors and upper-level windows needs to be repaired. Loose soffit on the West side of the garage needs to be repaired. Damaged roof decking seen at soffit area on the north of the garage indicates roof leakage and needs to be repaired in conjunction with the roof. The garage exterior staircase is heavily deteriorated and is not safe. The entire staircase and upper-level landing should be considered for being rebuilt at this time for safety. The garage lower rear wall North window sill is badly rotted and needs to be replaced. There is a section of split siding on the upper front wall of the garage that should be sealed to prevent water intrusion. Damage to trim on the rear header beam over the carport was noted and should be repaired. It would be wise to open this trim to be able to inspect the structural beam.

11 Exterior Figures Deterioration to wood trim elements Seal intersection of front porch and house 3 4 Decay at front entry roof rafter Keep window details well sealed

12 Exterior Figures 5 6 Seal around trim and soffits Rear bedroom window is badly deteriorated 7 8 Decay at NW window Miscellaneous damage to siding and trim

13 Exterior Figures 9 0 Loose soffit on west side of garage Decay to garage door trim Rot and leakage at garage roof north edge Rotted rear wall garage window sill

14 Exterior Figures 3 4 Garage stairs are very weak Split siding on upper front wall of garage 5 6 Seal AC line chase Damage to carport rear header beam

15 GROUNDS Driveway: Concrete Walkways: Concrete Patios: Concrete Partitions: Wood & Metal Overall grading: Negative grade* Irrigation system: No # of zones: Irrigation source: Retaining walls/bulkheads: None Most concrete driveways, paths, patios and walls will crack. This is not normally a structural problem and only major defects will be noted in this report. Related Notes: The property generally grades sharply towards the West, including the rear of the property behind the house. The grounds have been generally poorly maintained in recent history and several areas of erosion, where lowgrading traps moisture at the structure, were seen and should be addressed. Details for improvements regarding water management and general maintenance are detailed below. Maintenance Items: The fencing was found to be deteriorated with mildew damage and broken boards. Having the fencing cleaned and sealed at this time would help to extend its life but some replacement of fence material will be needed soon. Erosion was noted around the perimeter of the home as a result of roof water runoff. The most notable areas that appear to trap moisture include behind the carport, across the rear wall of the home, and at the sides of the front entry porch. I strongly recommend improving the grading in these areas or considering adding a partial gutter system to better control roof water drainage. The erosion behind the carport has started to undermine part of the concrete slab and should be addressed at this time. Much of the rear driveway is badly cracked and should be considered for replacement in the future. Negative grading in the rear of the garage as a result of the large tree and tree debris buildup over the years is projecting water towards the structure and should be addressed in the near future. I strongly recommend cleaning and sealing the wooden deck in the rear of the property at this time in order to help extend its life. Immediate Repairs: Trim all shrubbery and tree contact away from the building and roof at this time. The main electric service wires going to the house run through thick shrubbery and trees; trimming should be performed at this time. This may be a service offered for free by the electric company.

16 Grounds Figures Cracking to front porch should be sealed soon Trim back tree and shrubs from the house 3 4 Erosion behind carport Damage to drive

17 Grounds Figures 5 6 Deterioration to fencing Deterioration to rear deck

18 ROOF Main roof covering: Shingle 7 yrs Other roof coverings: Shingle + yrs Main roof shape: Gable Penetrations: Plumbing & Vents Active leaks: No & Chimney & Electric mast Recent roof updates: No Visible damage/deterioration: Yes, see below Remaining useful life of main roof surface (apprx): 3 yrs Unless otherwise noted below, all roof surfaces are accessed with a ladder and walked. Most roof surfaces are a decorative and protective covering for the waterproof underlayment and are not the water-proof layer themselves. It is common to have unevenness in roof lines, along with some undulation in the roof surface, and unless these are items of a structural nature they are not normally mentioned in this report. Periodic checks and maintenance of your roof surface will protect your roof from the elements. Related Notes: The roof is a 7 year old shingle and was found to be in sound condition for the most part. The shingles are extremely dirty with algae growth but I do not recommend cleaning them with pressure washing. If you wish to clean the roof, a light chemical rinse would be the best solution to preserve the shingles. There were no serious deficiencies noted to the main roof at the time of the inspection and appears to be on track for a normal lifespan of around 0 years. Some limited visibility existed as a result of tree cover over the South edge of the roof, see GROUNDS page. The garage roof appears to be quite a bit older and in a more advanced state of deterioration. Tree contact and heavy tree debris buildup on this roof were noted as well as evidence of active leakage. As detailed below, I recommend having the garage roof carefully inspected by a roofer at this time. Maintenance Items: The chimney was found to be generally deteriorated with weak and dirty mortar, deteriorated flashing sealant, and a very old and rusted chimney cap. I strongly recommend having the chimney reworked in the near future. Several roof penetrations on the main house are sealed with pitch pans; the sealant in these units is deteriorated and should be reapplied soon. Immediate Repairs: 3 Downspouts are missing at the carport gutter system and need to be installed. Evidence of leakage at the North edge of the garage roof was noted and needs to be addressed. Evidence of leakage over the NW section of the garage roof was noted. Tree contact and heavy tree debris buildup on this roof also needs to be addressed. I recommend having a roofer carefully inspect and repair the garage roof as needed at this time.

19 Roof Figures General view of roof front General view of roof rear 3 4 Tree contact on roof Deterioration to chimney

20 Roof Figures 5 Improved sealant needed at pitch pans soon

21 ATTIC 0 Attic access: Roof Framing: Sub roofing: Water stains: Visibility limited by: Hatch Conventional Planking Yes, see below Insulation & Ducting Ventilation: Insulation: Thickness: R value: Gable vents Fiberglass 3-4 inches 3 & Ridge vents Inspection of the attic areas will include checking for structural defects in the framing system, evidence of past/present roof leaks, and termite activity and damage. Plumbing vents, radon vents, and all exhaust fan vents should extend through the roof to remove gases and fumes to the exterior. Air conditioning ductwork should be checked routinely and open joints re-taped. There should be a minimum of 6 inches of insulation in the attic. Attics should be well ventilated with either soffit, gable or ridge vents. Turbines and fans can also be very useful. Unless stated, no visible signs of urea-formaldehyde or asbestos insulation was detected during the inspection. However, it is not possible to guarantee that it does not exist in hidden, concealed or inaccessible areas. Related Notes: The attic space was found to be typical for a home of this age with limited insulation and satisfactory ventilation overall. Evidence of termite damage was seen but it is generally superficial with no structural repairs needed at this time. Several roof deck boards were replaced along with a new roof, approximately 6 to 8 years ago and no visible signs of active water penetration were noted on the underside of the main house roof. It would be wise to consider adding more insulation in the future. Maintenance Items: There was no accessible attic space over the apartment. I strongly recommend creating an access for inspection and repair purposes.

22 Attic Figures General attic view

23 INTERIOR Walls: Ceilings: Floors: Windows: Water stains: Plaster Plaster Hardwood Wood Wood Metal Ceilings & Ceramic tile Single hung Fixed pane Single hung Screens: Doors: Cabinets: Counters: Tile work: Stairs/landings: Safety issues: Fireplace: No Hollow core & Bi-folds Wood & Laminate Solid surface & Laminate Maintenance needed N/A No Masonry The various stress and settlement cracks that develop in the inner walls are normal and cosmetic and will not be commented on unless they are serious in nature. Nail pops are also cosmetic. We cannot comment on cracks in concrete floors that are covered by carpeting etc. at the time of the inspection. Related Notes: The interior of the main house was found to be in fair condition overall but has suffered from cosmetic damage as a result of hard living and termites over the years. Whilst the damage is mostly cosmetic, you should anticipate that improvements will be needed when refinishing the floors or making other improvements to the interior. Several additional recommendations and observations are detailed below. Maintenance Items: 3 4 Several areas of cosmetic damage were seen to walls and ceilings in the apartment as a result of the structural movement that has taken place in this building. Additionally, water intrusion from roof leakage has caused damage and fungal growth. Some repairs are needed at this time to correct the plaster damage but it would also be wise to consider removing additional plaster in the affected structural and water damaged areas for better interior finish and to remove any material affected by fungus. Cosmetic termite damage was found on both the interiors of the main house as well as the apartment. Some of the damage has caused deterioration to flooring and trim and cosmetic repairs would be wise. The vast majority of the windows in the house were found to be sealed shut and many have suffered termite damage. Having the windows reworked for improved functionality would be wise in the future. The fireplace has been sealed and is not functional. Immediate Repairs: 3 Badly damaged ceiling in the apartment appears to be the result of active roof leakage. Repairs are needed at this time. The main house front doorknob is faulty and the door does not latch shut properly. This should be adjusted at this time for normal operation. Several very heavily damaged floorboards in the rear bedroom were found and they should be replaced at this time.

24 Interior Figures Water damage to plaster in apartment Settlement damage to plaster in apartment 3 4 Example of termite damage to windows and other trim Badly damaged flooring in rear bedroom

25 PLUMBING Service: Water meter checked: Water main: Supply pipes: Hose bibs: Public water & sewer Yes Age of system: Year of recent upgrades: Galvanized Steel Water softener: Copper & Galv. Steel Drain pipes: Adequate Backflow preventers: No PVC Recommended Water heater (s): Natural Gas Age: 5 years Capacity: 40 gallons Water heater (s): Electric Age: 7 years Capacity: 30 gallons (House) (Garage) Most public water in this area has a pressure range of 50 to 70 psi. You should be familiar with the location of the main water shut-off valve in the event of an emergency (see cover sheet). Sometimes low water pressure at a single faucet can be attributed to a clogged aerator filter. All plumbing fixtures must be either vented to the exterior via vent stacks to allow gasses to escape or connected with an air admittance valve to allow for proper drainage. Some liquid or crystal drain openers or cleaning chemicals are harmful to PVC piping, and it is recommended that you check the instructions on the product before using. Water heaters must be fitted with temperature pressure relief valves and the valve must have an extension on it that terminates no higher than 8 inches from the floor, or extends to the exterior of the building. Water heaters should be partially drained every months to get rid of sediment build-up. Related Notes: The system has been partially updated over the years but still appears to contain a fair amount of original material. I was unable to gain access under the kitchen and bathroom to inspect the plumbing due to low clearance under the house but what could be seen appears to be basically sound. Anticipate the need to perform plumbing updating on an as needed basis in the future. Maintenance Items: There was no gas turned on at the time of the inspection so all gas related appliances and equipment could not be fully tested, including the water heater. Immediate Repairs: The main house water heater gas line requires a drip leg. The main house water heater temperature and pressure relief valve requires an appropriate extension pipe. The vent on top of the main house water heater is improperly installed and needs to be corrected by a licensed plumber for safety. The apartment toilet leaks badly when flushed and needs to be corrected. The apartment shower handle leaks and also needs to be corrected. The apartment bathroom sink is badly cracked and needs to be replaced. A section of corrugated flexible pipe has been used as a horizontal drain under the main house kitchen sink. This type of piping traps debris and should be replaced with appropriate drain pipe at this time. The main house toilet is very loose and needs to be properly secured on the floor. The main house kitchen sink faucet stem leaks and should be corrected.

26 Plumbing Figures Main water shut-off valve Missing TPR extension pipe 3 4 Improperly installed vent at main house water heater Corrugated piping under kitchen sink

27 Plumbing Figures 5 6 Apartment water heater Gas meter 7 Damaged apartment sink

28 ELECTRICAL Total System Amps: 00 amps Year last Updated: 008 Age of main panel: ~5 Main Panel Amps: 00 amps Garage Panel Amps: 00 amps Main Panel Make: G.E. Sub Panel Make(s): G.E. Main disconnect: Breaker(s) Branch circuit disconnect: Breaker(s) Main service wire: Aluminum Branch circuitry type: PVC clad copper GFCI's: Some Smoke alarms: Hardwired AFCI's: Not present CO detectors: None (Copper) & Knob and Tube GFCI (ground fault circuit interrupters) and AFCI (arc fault circuit interrupters) are protective devices designed to shut off the power to certain circuits in the event of a problem on that particular line and are required on all new homes and recommended for older homes on all circuits with close proximity to water, on all outside circuits and for bedroom circuits. They should be tested periodically as per the manufacturers instructions The house main must be grounded securely, either to a metal ground spike or a plumbing pipe. If the service entry wires come into the house via a pole or mast, they must be securely anchored and kept clear of tree limbs. If the panel is located on the exterior of the home, it is wise to trip and reset the breakers periodically to help prevent corrosion build-up and the risk of sticking breakers. Always have a licensed electrician make all electrical repairs in the home for safety. Related Comments: The main house appears to have been fully rewired in stages over the past 5 to 5 years and there was no evidence of active original wiring noted at the time of the inspection. The service appears to be coping with the needs of the home and inspected well overall. Several deficiencies were found, however, that should be corrected at this time regarding the main house, as well as the apartment, and are detailed below. Maintenance Items: Media wires hang low over the driveway between the garage and the house and should be raised for safety. I strongly recommend creating a three-way light switch at both the top and bottom of the apartment stairs to meet modern safety requirements. Be aware that the main service entry wires for the apartment are very close to the upper-level staircase landing; use caution but consider relocating these wires in the future. Quite a lot of original knob and tube wiring was found in the attic of the main house. All of the material that could be accessed tested as dead but it would be wise to remove it in the future to avoid confusion. I recommend installing new smoke alarms at this time. Immediate Repairs: Missing knock-out at the garage main electric panel needs to be replaced. The main breaker for the garage service is 00 A. This is oversized considering the size of the main service wire and should be corrected by an electrician. Many exposed wires in the garage should be protected behind paneling or in conduit. The AC condenser unit disconnect box is missing a knock-out on the side and should be corrected. This box is starting to rust aggressively and should be considered for replacement soon. Active knob and tube wiring was found in the apartment. Have an electrician replace all such wiring as needed at this time.

29 Electrical Figures Main electrical panel Garage service panel 3 4 Over-sized breaker at garage service panel Missing knock-out at garage service panel

30 Electrical Figures 5 6 Many exposed wires in garage AC disconnect has missing knock-out and is badly rusted 7 8 Main service wire going through trees Knob and tube wiring seen in the apartment

31 APPLIANCES Single oven: Burners: Ventilation: Microwave: Dishwasher: Refrigerator: Disposal: Electric Electric Re-circulating Satisfactory Satisfactory Frost free Satisfactory Washing machine: Electric dryer: Dryer venting: Bathroom exhaust venting: Ceiling fans: Additional appliances: & Ice maker Satisfactory Satisfactory Through side wall Into attic Satisfactory N/A As a courtesy and, where possible, appliances are checked for normal operation. Re-check them on your pre-settlement walk-through. This check is a cursory test for general functionality and is not a full evaluation. Related Notes: All appliances were tested. The main house appliances appear to be approximately 7 years old and in good physical condition overall. The apartment appliances are older and do show several deficiencies, see below. Maintenance Items: Keep the dryer vent cleaned out on a routine basis. Use high quality washing machine hoses and check regularly for distress. Immediate Repairs: The apartment refrigerator did not appear to initiate properly. The apartment kitchen ceiling fan did not turn on.

32 Appliances Figures Appliance view Washer and dryer

33 Heating/Cooling Cooling system : Heating system : Type Heat pump Heat pump Fuel Type Size Manufacturer Electric 3 tons Carrier Electric 3 tons Carrier Age Temp. Dif. 7 yrs 5+ F 7 yrs Recent upgrades: None *see below for a description of recent upgrades Filtration: Distribution: Flex duct & Fiberglass Condensate removal: Overflow protection: Disposable Primary drain Float switch & Drain pan Ages are approximate. The external unit (condenser) should be maintained in a level position and kept clear of shrubbery, etc. for maximum air flow. Most systems have a separate air handler and filter inside the house. Condensate run-off is usually by gravity but sometimes a lift pump is deployed. Some overflow drain pans are fitted with float switches which are de-signed to shut the system down in the event of excess water in the drain pan (usually caused by blocked condensate drain pipe), and thus avoid water spillage. Window air conditioners should tilt outwards to project condensation away from the property. The normal acceptable cooling temperature differential between the supply and return air is 5 to degrees. Any number outside of this range usually indicates a need for servicing. It is not recommended to operate the air conditioning system unless the outside temperature is over 65 degrees as this can damage the compressor. Likewise, you should not operate the heating cycle of a heat pump unless the outside temperature is under 65 degrees. Never turn the heating or cooling on and off in rapid succession. Related Notes: The system tested to industry standards at the time of the inspection but I suspect it is dirty based on a musty smell when operating and dirt at ceiling registers. As noted below, I strongly recommend having the system cleaned and serviced at this time as part of routine maintenance. The system should cope with the needs of the home and perform well for several more years if properly maintained. Maintenance Items: Use good quality filters and change according to the manufacturer's recommendations. Have the system regularly cleaned and serviced to extend their lives and ensure maximum operating cleanliness and efficiency. The apartment is supplied with a single air-conditioning window unit that appears to be straight cool. The unit appeared to be operating normally at the time of the inspection. Ceiling registers in the main house were found to be quite dirty overall and I suspect that the ducting and air handler is also dirty. It would be wise to clean all accessible air-conditioning components at this time. Ducting in the main house was found to be in very poor condition overall and I strongly recommend replacing it proactively as soon as possible. Immediate Repairs: Several of the duct boxes in the attic over ceiling registers are loose and improperly secured and should be secured and sealed at this time.

34 HVAC Figures Condenser view Air handler view 3 4 Example of mildew on AC registers Example of deteriorated ducting in attic

Inspection Report. Property Address:

Inspection Report. Property Address: Inspection Report provided by: Safe Side Home Inspection Inspector: Corey Stuart TN License # 778 434 Margaret Circle McMinnville, TN 37110 safesideinspection@blomand.net Property Address: 1234 Anywhere

More information

Inspection Report. Prepared for: Yossi Berg. Property Address: 4925 Diggers Way Sugar Hill, GA. Date: July 20, 2011

Inspection Report. Prepared for: Yossi Berg. Property Address: 4925 Diggers Way Sugar Hill, GA. Date: July 20, 2011 Inspection Report Prepared for: Yossi Berg Property Address: Sugar Hill, GA. Date: July 20, 2011 Inspector: Charles Mann (770) 594-2222 www.edificeinspections.com Page 1 INSPECTION CONDITIONS CLIENT &

More information

Alabama Home Inspections

Alabama Home Inspections Cover Page Property Inspection Report 1000 Sample Dr., Sampletown USA Inspection prepared for: Report Sample Inspection Date: 1/21/2010 Time: 400pm Size: Approx. 2,200sf Weather: Cloudy 62 Inspector: Bobby

More information

Inspection Report. Prepared for: Tonia Mann. Property Address: 2557 Briar Valley Way Dacula, GA Date: March 01, 2012

Inspection Report. Prepared for: Tonia Mann. Property Address: 2557 Briar Valley Way Dacula, GA Date: March 01, 2012 Inspection Report Prepared for: Tonia Mann Property Address: Dacula, GA 30019 Date: March 01, 2012 Inspector: Charles Mann (770) 594-2222 www.edificeinspections.com Page 1 INSPECTION CONDITIONS CLIENT

More information

Inspection Report. Prepared for: Gil Turiel. Property Address: 545 Briar Run Court Loganville, GA Date: July 17, 2011

Inspection Report. Prepared for: Gil Turiel. Property Address: 545 Briar Run Court Loganville, GA Date: July 17, 2011 Inspection Report Prepared for: Gil Turiel Property Address: Loganville, GA 30052 Date: July 17, 2011 Inspector: Charles Mann (770) 594-2222 www.edificeinspections.com Page 1 INSPECTION CONDITIONS CLIENT

More information

Home Condition Checklist

Home Condition Checklist Home Condition Checklist What to bring: 1. Flashlight 2. Pen 3. Paper 4. Gloves 5. Old Clothes/shoes 6. This list Start with the exterior of the home and work in one direction, with enough distance to

More information

Property Inspection Report

Property Inspection Report DAVID A. MEACHAM Professional Inspection & Construction Services Property Inspection Report Prepared for David Smith Property Address 1154 Gulf View Drive Tampa Bay, Florida Inspection Date Friday, October

More information

GROUNDS Grading General Grading, slope and drainage: Satisfactory N/A See Notes. Grading and slope at house wall

GROUNDS Grading General Grading, slope and drainage: Satisfactory N/A See Notes. Grading and slope at house wall GROUNDS Grading General Grading, slope and drainage: Satisfactory Grading and slope at house wall Satisfactory (within 5 feet from building) Sidewalk Concrete Brick Flagstone Other Patio stones Driveway

More information

Inspection Report. Prepared for: Tonia Mann. Property Address: 1295 Greyland Hills Drive Lawrenceville, GA Date: April 24, 2012

Inspection Report. Prepared for: Tonia Mann. Property Address: 1295 Greyland Hills Drive Lawrenceville, GA Date: April 24, 2012 Inspection Report Prepared for: Tonia Mann Property Address: Lawrenceville, GA 30046 Date: April 24, 2012 Inspector: Charles Mann (770) 594-2222 www.edificeinspections.com Page 1 INSPECTION CONDITIONS

More information

Exterior structures (fences, sheds, decks, retaining walls, detached garages) in good condition, no evidence of termite damage or rotted wood

Exterior structures (fences, sheds, decks, retaining walls, detached garages) in good condition, no evidence of termite damage or rotted wood Please Note: This checklist should not be relied upon as a home inspection report, nor should it be considered a substitute for a home inspection. This list is representative, but NOT exhaustive. If you

More information

Inspection Report. Prepared for: Yaron Sternberg. Property Address: 926 Hemingway Road Stone Mountain, GA. Date: April 15, 2011

Inspection Report. Prepared for: Yaron Sternberg. Property Address: 926 Hemingway Road Stone Mountain, GA. Date: April 15, 2011 Inspection Report Prepared for: Yaron Sternberg Property Address: Stone Mountain, GA. Date: April 15, 2011 Inspector: Charles Mann (770) 594-2222 www.edificeinspections.com Page 1 INSPECTION CONDITIONS

More information

Property Inspection Checklist

Property Inspection Checklist Property Inspection Checklist Use a checklist like this to make sure that you are looking at all parts of the house. Check off those items that are in good condition and make notes about those that are

More information

SUMMARY 1234 Main St.Loudon TN Buyer Name 08/28/2018 9:00AM

SUMMARY 1234 Main St.Loudon TN Buyer Name 08/28/2018 9:00AM SUMMARY 1234 Main St.Loudon TN 37774 Buyer Name 08/28/2018 9:00AM Dusty Jameson TN Home Inspector License #00123, TN WDI License #104158 Inspector Cluseau's Home Inspection Service 865-691-6158 dustyjameson@gmail.com

More information

Inspect Hawaii. Property Inspection Report

Inspect Hawaii. Property Inspection Report Cover Page Property Inspection Report 96744 Inspection prepared for: John Doe Date of Inspection: 11/6/2014 Inspector: Oscar Libed ASHI License #257117 Honolulu, HI 96825 Email: oscar@inspecthawaii.com

More information

1234 Main St. Buyer Name. Table of Contents

1234 Main St. Buyer Name. Table of Contents AMERICAN PROFESSIONAL HOME INSPECTION 719.648.4098 drew@americanprofessionalhomeinspection.com http://www.amproinspection.com RESIDENTIAL REPORT 1234 Main St. Colorado Springs CO 80903 Buyer Name 10/02/2017

More information

SureHome Inspection Company. Home Inspection. Grant st Street Omaha, NE 68048

SureHome Inspection Company. Home Inspection. Grant st Street Omaha, NE 68048 Home Inspection Grant 7142 21st Street Omaha, NE 68048 Page 1 of 13 Table of Contents Definitions 2 General Information 2 Roof 3 Exterior 4 Grounds 5 Attic 5 Garage 6 Bathroom 6 Interior 7 Kitchen 7 Laundry

More information

Pre-Listing Home Inspection Checklist

Pre-Listing Home Inspection Checklist Pre-Listing Home Inspection Checklist Charles Guth P.A. Homeward R.E. CharlesGuth.com 727-709-4663 Prior to putting your home on the market it is a recommended that you have your home pre-inspected to

More information

The Inspector. Property Inspection Report

The Inspector. Property Inspection Report Cover Page The Inspector Property Inspection Report Inspection prepared for: ******** ******* Date of Inspection: 11/18/2013 Time: 12PM Age of Home: unknown Size: 2000sf Weather: overcast / 40 Inspector:

More information

3D Home Improvement and Inspection Services, Inc

3D Home Improvement and Inspection Services, Inc Property Inspection Report Cover Page ABC Disney Lane, Winter Garden FL, 34787 Inspection prepared for: John Doe Inspection Date: 7/15/2010 Time: 11:00 am Age: 6 Years Size: 3,378 LSF / 4,427 TSF Weather:

More information

Total Home Inspection Checklist

Total Home Inspection Checklist TOTAL HOME INSPECTION CHECKLIST Total Home Inspection Checklist Use a checklist like this to make sure that you are looking at all parts of the house. Check off those items that are in good condition and

More information

component was performing its intended function; installation and condition were appropriate for age and use.

component was performing its intended function; installation and condition were appropriate for age and use. April 23, 2012 Dear Home Seller, On April 6, 2012, Cities Inspection Service, Inc. completed a home inspection of the property located at 123 Oak Drive, Somewhere, Minnesota for you. Doug Hastings did

More information

All Pro Home Inspection. Home Report South Your Town

All Pro Home Inspection. Home Report South Your Town Home Report 9999 South Your Town Page 1 of 22 Not Inspected Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended

More information

Inspection Report. Prepared for: Tonia Mann. Property Address: 56 Riverview Place Douglasville, GA Date: September 19, 2012

Inspection Report. Prepared for: Tonia Mann. Property Address: 56 Riverview Place Douglasville, GA Date: September 19, 2012 Inspection Report Prepared for: Tonia Mann Property Address: Douglasville, GA 30134 Date: September 19, 2012 Inspector: Charles Mann Edifice Inspections, Inc. (770) 594-2222 www.edificeinspections.com

More information

Calidad Home Inspection Colleyville, TX (817) /

Calidad Home Inspection Colleyville, TX (817) / Calidad Home Inspection Colleyville, TX 76034 (817) 896-1203 / info@calidad-tx.com This Professional Inspection Report Has Been Prepared Exclusively For: Mr and Mrs Home Buyer Kings Ranch RoadRIver Oaks,

More information

HOME INSPECTION CHECKLIST

HOME INSPECTION CHECKLIST CLOSING.COM LEARNING CENTER HOME INSPECTION CHECKLIST CONTENTS Attic 1 Balconies 1 Basement 1 Bathroom 2 Ceiling, Floors and Walls 2 Crawlspace 3 Decks and Porches 3 Doors and Windows 4 Drainage 4 Driveways

More information

6954 Lakeside Dr. Property Inspection Report. - Provided by First Class Property Inspections, LLC -

6954 Lakeside Dr. Property Inspection Report. - Provided by First Class Property Inspections, LLC - 6954 Lakeside Dr. Property Inspection Report - Provided by First Class Property Inspections, LLC - Site and Conditions at time of Inspection Street Address 6954 Lakeside Dr. City, State, Zip Apollo Beach,

More information

Home Inspection Report

Home Inspection Report Home Inspection Report 1234 School House Road Yourtown, Yourstate 12345 Prepared for: Mr. and Mrs. Home Buyer Prepared by: 1217 Cape Coral Parkway East #177 Cape Coral, Florida 33904 Phone: (239) 322-0836

More information

HOME MAINTENANCE GUIDE KEEPING YOUR HOME IN EXCELLENT CONDITION

HOME MAINTENANCE GUIDE KEEPING YOUR HOME IN EXCELLENT CONDITION HOME MAINTENANCE GUIDE KEEPING YOUR HOME IN EXCELLENT CONDITION Canada s Premier Inspection Service HOME MAINTENANCE GUIDE By conducting regular maintenance checks, you can prevent small inexpensive repairs

More information

A Sample Report On The Conditions At:

A Sample Report On The Conditions At: HomeInfo, LLC Information You Deserve 3620 McCurdy Street Montgomery, AL 36111-2148 334-303-4284 Office 334-264-7755 Fax A Sample Report On The Conditions At: 123 Main Street Anytown, Alabama 36101-1101

More information

Madison's Home Inspections

Madison's Home Inspections Cover Page Madison's Home Inspections Property Inspection Report my street, Clarksville TN, 37043 Inspection prepared for: Gary Mann Agent: gary mann - Madison's Inspection Date: 0/4/2009 Time: 12 pm Age:

More information

Inspection Services of the Treasure Coast

Inspection Services of the Treasure Coast Property Inspection Report Cover Page 34951 Inspection prepared for: Ute Griffin Date of Inspection: 12/5/2012 Time: 1:30pm Age of Home: 49 Size: 1512sq. ft. Weather: 70 partly cloudy Inspector: Gary C.

More information

JBR Property Inspections

JBR Property Inspections Cover Page Property Inspection Report 37321 Inspection prepared for: Tyler & Beth Example Date of Inspection: 12/10/2014 Time: 11:00 Age of Home: 12 Years Size: 4900 sqft. Weather: 41 Degrees, Partly Cloudy

More information

Home Inspection Checklist

Home Inspection Checklist Home Inspection Checklist Property Address 4003 Paloma Cir, Austin, TX 78734, USA Conducted on 24 Oct 2018 05:52 PM Prepared by Adam Alexander Prepared for Dianna Stevens Completed on 24 Oct 2018 06:05

More information

FINEGAN INSPECTION SERVICES, INC.

FINEGAN INSPECTION SERVICES, INC. FINEGAN INSPECTION SERVICES, INC. TERRY FINEGAN 76 WEST FOSTER MAINEVILLE ROAD MAINEVILLE, OHIO 45039 683-0733-PHONE 697-0163-FAX Email- finegan @ fuse.net CLIENT: 1/14/08 Mr. BUILDING LOCATION As in all

More information

Friendly Inspection Services

Friendly Inspection Services Cover Page Friendly Inspection Services Property Inspection Report Inspection prepared for: Sample Report Date of Inspection: 4/15/2015 Time: 12:30 Start, 3:15 finish Age of Home: 1986 Weather: Sunny,

More information

1234 Main St Denver CO 80210

1234 Main St Denver CO 80210 BEST HOME INSPECTIONS 555-555-5555 best@inspections.com https://www.spectora.com HOME INSPECTION REPORT 1234 Main St Denver CO 80210 NOVEMBER 21, 2016 Inspector John Smith sample@spectora.com Buyer Michael

More information

Property Inspection Report

Property Inspection Report Property Inspection Report 17763 ABC Court San Diego, CA 92131 Page 1 of 26 Table of Contents Definitions 2 General Information 2 Lots and Grounds 2 Exterior Surface and Components 4 Roof 6 Garage/Carport

More information

My Home Was Built In What Can I Expect To See On My Report?

My Home Was Built In What Can I Expect To See On My Report? My Home Was Built In 1956. What Can I Expect To See On My Report? Common Issues in 40 70 Year Old Homes Evidence of foundation settlement Older roof, limited service life remaining Older electrical system

More information

TML Home Inspectors, Inc.

TML Home Inspectors, Inc. TML Home Inspectors, Inc. CallHomeInspector.com Email: tmlhomeinspectors@gmail.com Ph. (630) 841 7333 Inspector: Jerry Zieleziecki License # 450.00xxxx Expiration Date: 11/30/2014 Date: Time: Property

More information

Inspection Report. 1 of 8

Inspection Report. 1 of 8 Inspection Report Dayvolt's Home Inspections L.L.C. Date&Time of Inspection: 5/9/17, 12:10 PM Inspector's Name: Dustin Dayvolt Building Address: Sample City: State: Zip Code: Type of property inspected:

More information

Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free

Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free / / Paperport 2000 official estimating report Work Write Up / Specification of Repairs Toll Free 1-877-932-7177 Clients Name. GREAT CLIENT Property Address. NUMBER ONE GOOD ROAD METRO, VA 20000 Primary

More information

GENERAL INFORMATION BUILDING INFORMATION ACRONYM RATING DEFINITIONS

GENERAL INFORMATION BUILDING INFORMATION ACRONYM RATING DEFINITIONS GENERAL INFORMATION Page 2 of 15 Company Name Company Address 106 East Road City Mt. Airy State MD Zip 21771 Phone 301-829-5706 Fax 301-829-5707 Inspector Name Fred Heskett, ACI ASHI #200346, MD HI #29377,

More information

Friendly Inspection Services

Friendly Inspection Services Cover Page Friendly Inspection Services Property Inspection Report Inspection prepared for: Sample Report Date of Inspection: 4/6/2015 Time: 8:45 Start, 11:10 finish Age of Home: 1950 Weather: cloudy,

More information

Home Inspection Report

Home Inspection Report Home Inspection Report Example Home Inspection Report. Page 1 of 17 Table of Contents Definitions 2 Company Information 2 General Information 2 Lots and Grounds 3 Exteriors 3 Garage/Carport 4 Roof 5 Attic

More information

Safety Money Repair Maintenance Evaluate Monitor Comment

Safety Money Repair Maintenance Evaluate Monitor Comment Safety Money Repair Maintenance Evaluate Monitor Comment Client John Smith 12 Madison Avenue Colonie, 12205 HIN : 122052297 Email: jsmith@yahoob.com Inspection Date: 02-04-2014 Inspector, Phone: E-Mail:

More information

Accurate Inspections Inc. Property Inspection Report

Accurate Inspections Inc. Property Inspection Report Property Inspection Report 727 Fairview Ave Unit C, Arcadia, Inspection prepared for: Agent: Jeffrey Wung - Coldwell Banker Residential Brokerage Inspection Date: 8/28/2007 Inspector: Mike Verlingo 914

More information

The Home Doctor, Inc.

The Home Doctor, Inc. February 7, 2013 The Home Doctor, Inc. Property: 26147 HUNTER GATES RD. LESTER, AL 35647 Client: JOHN DOE HOME INSPECTIONS With over 10,000 since 1994 1-800-246-4362 SUMMARY PAGE CLIENT(S): JOHN DOE ADDRESS:

More information

Friendly Inspection Services

Friendly Inspection Services Cover Page Friendly Inspection Services Property Inspection Report Inspection prepared for: Sample Report Date of Inspection: 3/25/2015 Time: 8:45 Start, 11:35 finish Age of Home: 1969 Weather: Sunny,

More information

HOME INSPECTION REPORT Prarie Circle

HOME INSPECTION REPORT Prarie Circle HOME INSPECTION REPORT 6245 Prarie Circle Mississauga Prepared for: Kevin Alvarez Prepared by: Bob Papadopoulos P.Eng., RHI * Inspection Date: April 23 2015 www.redbrickinspections.ca bob@redbrickinspections.ca

More information

A 1 Professional Home Inspection 14 Brevoort Pl. Deer Park, NY Jamaica, NY 11434

A 1 Professional Home Inspection 14 Brevoort Pl. Deer Park, NY Jamaica, NY 11434 14 Brevoort Pl. Deer Park, NY 11729 Jamaica, NY 11434 Page 1 of 30 Definitions NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection

More information

State Home Inspector Lic. # HI3986 Termite Inspector License # JE187661

State Home Inspector Lic. # HI3986 Termite Inspector License # JE187661 Office Number: (407) 393-8819 Email: uniqueinspreports@gmail.com Website: uniquepropertyinspections.com State Home Inspector Lic. # HI3986 Termite Inspector License # JE187661 This report has been prepared

More information

Hawks Eye Home Inspection LLC. Shoreline, Wa Williams Rd. Renton, Wa 98057

Hawks Eye Home Inspection LLC. Shoreline, Wa Williams Rd. Renton, Wa 98057 Shoreline, Wa 98155 Renton, Wa 98057 Page 1 of 23 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior 4 Roof 5 Garage/Carport 6 Electrical 7 Structure 8 Attic 10 Basement

More information

Rental Inspection Checklist

Rental Inspection Checklist Rental Inspection Checklist Address: Date: NOTE: The water, gas and/or electrical services were off at the time of inspection. A re-inspection at a later date SHALL BE required to inspect these items.

More information

Hogue Home Inspections

Hogue Home Inspections Page 1 of 31 Hogue Home Inspections 10382 WEST MEADOWLARK DRIVE BOISE, IDAHO 83704 (208)-841-9029 Customer MOUNTAIN AMERICA CREDIT UNION Inspected Property NAMPA, ID 83687 Real Estate Agent BEN FULCHER

More information

FAIRA TRANSPARENCY REPORTS Robert Wayne Dr, Pasco, WA July 18 th, 2017

FAIRA TRANSPARENCY REPORTS Robert Wayne Dr, Pasco, WA July 18 th, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 6114 Robert Wayne Dr, Pasco, WA

More information

New Hope Inspections, LLC Property Inspection Report

New Hope Inspections, LLC Property Inspection Report Cover Page Property Inspection Report 30025 Inspection prepared for: Chris Bell Real Estate Agent: - Date of Inspection: 3/20/2017 Time: 12:00pm Age of Home: 57 Size: 1,499 Weather: Clear Inspector: Joel

More information

Home Inspection Report

Home Inspection Report Home Inspection Report 1 of 16 Table of Contents Definitions 2 General Information 2 Electrical 3 Roof 7 HVAC System 10 Plumbing 12 2 of 16 Definitions NOTE: All definitions listed below refer to the property

More information

Red Rock Home Inspections

Red Rock Home Inspections Cover Page Property Inspection Report Inspection prepared for: Satisfied Customer Real Estate Agent: - Date of Inspection: 8/19/2016 Time: 8:00 AM Age of Home: 1991 Size: 2248 Weather: Hot/Sunny Order

More information

SITE AND BUILDING INSPECTION CHECKLIST

SITE AND BUILDING INSPECTION CHECKLIST PARISH BUILDING Page 1 of 6 SITE AND GROUNDS DATE INIT COMMENTS DATE INIT COMMENTS Ramps & Provisions for Handicap Designated parking spaces for Handicap Has soil dropped or heaved Is there standing water

More information

Pinnacle Home Inspections, Inc. Serving Central Arkansas

Pinnacle Home Inspections, Inc. Serving Central Arkansas Page 1 of 19 Pinnacle Home Inspections, Inc. Serving Central Arkansas 501-833-8500 Printed Wednesday, June 22, 2005 Inspected By: COLBY NEAL Client Information: Record Number 1 TEST, REPORT 123 YOUR STREET

More information

SOUTH CAROLINA HOME INSPECTOR STANDARDS OF PRACTICE

SOUTH CAROLINA HOME INSPECTOR STANDARDS OF PRACTICE SOUTH CAROLINA HOME INSPECTOR STANDARDS OF PRACTICE The following Standards provide guidelines for the Residential Home Inspector. The guidelines outline what the Residential Home Inspector should observe,

More information

Accurate Home Inspection of Illinois. Property Inspection Report For Tammy Limberopoulos S. Royal Crest Dr., Crete, Illinois

Accurate Home Inspection of Illinois. Property Inspection Report For Tammy Limberopoulos S. Royal Crest Dr., Crete, Illinois Accurate Home Inspection of Illinois 815-260-1727 1213 Norley st. Joliet, illinois 60435 Aaccurate1@yahoo.com We Inspect to Protect!!! Property Inspection Report For Tammy Limberopoulos 26126 S. Royal

More information

Date of Inspection: April 30th 2006 Client: Ivan M. House Inspector: Lee Ottewell (CPBC License #: 47384)

Date of Inspection: April 30th 2006 Client: Ivan M. House Inspector: Lee Ottewell (CPBC License #: 47384) Crest Building Consultancy Ltd. 5382 Parker Avenue, Victoria V8Y 2M9 phone: 250 888 9182 fax: 250 727 3723 e-mail: inspections@shaw.ca web: www.crestbc.ca Building Inspection 1432 Anyroad, Anytown Date

More information

Inspections Unlimited 12:38 August 20, 2013 Page 1 of 23 Sampleweb2013.pt6

Inspections Unlimited 12:38 August 20, 2013 Page 1 of 23 Sampleweb2013.pt6 12:38 August 20, 2013 Page 1 of 23 Table of Contents General Information 2 Component Ratings 3 Roof Surface 4 Lots and Grounds 5 Exterior Surface and Components 7 Garage/Carport 8 Kitchen 8 Living Space

More information

Jardine Place, Toronto, Ontario

Jardine Place, Toronto, Ontario National Home Inspection Ltd. 1055 Woodbine Avenue Toronto, Ontario M4C 4C2 TEL: (416) 467-7809 www.nationalhomeinspection.ca Jardine Place, Toronto, Ontario 1 National Home Inspection Ltd. 1055 Woodbine

More information

Home Inspection Report

Home Inspection Report Pfeifer Home Inpsection, LLC 8332 Crystal Pointe Lane Indianapolis, Indiana 46236 317-340-1734 Lic #HI01700103 Home Inspection Report Indianapolis, IN 46236 Page 1 of 24 Table of Contents Definitions 2

More information

Walnut Creek Mutual Seventy

Walnut Creek Mutual Seventy Appliances: Dishwashers, Refrigerators, Disposals, Ranges, Ovens, Vents, Hoods, Fireplaces, Washing Machines, Dryers, etc. All appliances are the owner s property; all maintenance and repair is the owner

More information

Building Inspection Report

Building Inspection Report 2053 Quincy Ave. Racine, WI 53403 Building Inspection Report Residential Property Page 1 of 11 Definitions NOTE: All definitions listed below refer to the property or item listed as inspected on this report

More information

TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up

TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM Form 15 Work Write-Up Owner-Builder Applicant Owner-Builder Co-Applicant Physical Address: City,

More information

INSPECTOR CLUSEAU'S HOME INSPECTION SERVICE

INSPECTOR CLUSEAU'S HOME INSPECTION SERVICE INSPECTOR CLUSEAU'S HOME INSPECTION SERVICE 865-691-6158 dustyjameson@gmail.com http://www.inspector-cluseau.com INSPECTION REPORT 1234 Main St. Loudon TN 37774 Buyer Name 03/28/2018 9:00AM Inspector Dusty

More information

REPORT CHECKLIST SUPPLEMENT

REPORT CHECKLIST SUPPLEMENT REPORT CHECKLIST SUPPLEMENT This checklist will assist in assuring that a home inspection report complies with The Arizona Standards of Professional Practice for Home Inspectors For use by: Applicants,

More information

InterNACHI Home Inspection Report Checklist

InterNACHI Home Inspection Report Checklist Client name: Inspected property address: Date and time of the inspection: Weather conditions: Approximate outdoor air temperature: People present at the time of the inspection: Estimated year built: Type

More information

Bill Ostoyic Building Inspection Report XXXXXXX XXXXX XXXXX, Fl. Licensed and Insured

Bill Ostoyic Building Inspection Report XXXXXXX XXXXX XXXXX, Fl. Licensed and Insured Bill Ostoyic 407-756-0527 Building Inspection Report XXXXXXX XXXXX XXXXX, Fl Licensed and Insured Inspection Date: XXX.XX, XXXX Prepared For: XXXXXX XXXXXXX Prepared By: AAPI inc. Report Number: XXXXXXXX

More information

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS St. Louis County Department of Public Works Division of Code Enforcement HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS This guide is intended to provide the homeowner or contractor with the

More information

Inspection Report. Prepared For: John Smith. Property Address: 1234 N. Gilbert Rd. Gilbert AZ Inspected By: Timothy O'Neall

Inspection Report. Prepared For: John Smith. Property Address: 1234 N. Gilbert Rd. Gilbert AZ Inspected By: Timothy O'Neall Inspection Report Prepared For: John Property Address: 1234 N. Gilbert Rd. Gilbert AZ 85258 Inspected By: Timothy O'Neall 3961 E. Chandler Blvd., #111-236 Phoenix, AZ 85048 480-694-0650 InspectionsAZ.com

More information

My Safe Home Inspection

My Safe Home Inspection Cover Page Propery Inspection Report 33469 Inspection prepared for: Dennis Medaglia Date of Inspection: 7/7/2016 Time: 1pm Age of Home: 1991 Size: 2393 Weather: Warm/Partly Cloudy Inspector: Matthew Miles

More information

SUMMARY 792 Youngfield Ct., Lakewood CO Frank Oz January 13, 2018

SUMMARY 792 Youngfield Ct., Lakewood CO Frank Oz January 13, 2018 SUMMARY 792 Youngfield Ct., Lakewood CO 80228 Frank Oz January 13, 2018 Christopher Grabbe internachi Certified Professional Inspector FirePower Inspections 7204645889 info@firepowerinspections.com 2.1.1

More information

Inspection Report. Jay Coleman. Property Address: Cooper Rd Brookshire TX Bill Harvey Inspection Services

Inspection Report. Jay Coleman. Property Address: Cooper Rd Brookshire TX Bill Harvey Inspection Services Inspection Report Jay Property Address: 35505 Cooper Rd Brookshire TX 77423 Bill Harvey Inspection Services Bill Harvey 5648 13119 Jasper Lane Cypress TX 77429 281-477-7875 Table of Contents Cover Page...1

More information

Home. Safe. Home. home inspection report

Home. Safe. Home. home inspection report home inspection report Home. Safe. Home. Each office is independently owned and operated. 2013 The HomeTeam Inspection Service, Inc. All rights reserved. What is a home inspection? The purpose of a home

More information

J & M Solutions, LLC

J & M Solutions, LLC Cover Page Property Inspection Report 81089 Inspection prepared for: Noneya Buisness Real Estate Agent: Support - Home Inspector Pro Date of Inspection: 6/13/2017 Time: 3:30 PM Age of Home: 2002 Size:

More information

Home Inspection Report

Home Inspection Report Home Inspection Report 1 Anywhere Ct. Heath, TX 75032 PROPERTY INSPECTION REPORT Prepared For: Mr. & Mrs. Happy Homebuyer Concerning: 1 Anywhere Ct. Heath, TX 75032 Inspection Date: 06/21/2017 By: Inspector

More information

Ohio Home Inspection Organization

Ohio Home Inspection Organization Cover Page Property Inspection Report 43555 Inspection prepared for: John & Jane Doe Real Estate Agent: - Date of Inspection: 7/13/2013 Time: 9:00 AM Age of Home: 1976 Size: 1328 Sq. Ft. Weather: 80 Sunny

More information

1st Defense Home Inspections, LLC

1st Defense Home Inspections, LLC Cover Page 1st Defense Home Inspections, LLC Property Inspection Report 1234 East Cornwall Ave., Las Vegas NV Inspection prepared for: Joe Smith Agent: Steve Howell - Prudential Americana Group Inspection

More information

Advanced Home Inspections

Advanced Home Inspections 12:13 January 30, 2014 Page 1 of 15 Definitions NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection A Acceptable Functional with

More information

SUMMARY 1234 Main St.Hamilton Ohio Buyer Name 07/03/2018 9:00AM

SUMMARY 1234 Main St.Hamilton Ohio Buyer Name 07/03/2018 9:00AM SUMMARY 1234 Main St.Hamilton Ohio 45013 Buyer Name 07/03/2018 9:00AM Todd Engle,CMI Certified Master Inspector Good Eye Home Inspections 859-630-4659 toddthehomeinspector@gmail.com Client information:

More information

This report is general in nature and not technically exhaustive.

This report is general in nature and not technically exhaustive. BHI, LLC 38 Dana Place / Closter, NJ 07624 NJ Home Inspector Lic. # 24G100020400 NJDEP Radon Lic # Met 109-74 Phone # 201-767-2070 Fax # 201-767-3020 Craig Sharf File Number: 315-062009-xxxx Address of

More information

TruView Inspections (HI7112)

TruView Inspections (HI7112) TruView Inspections (HI7112) (786) 261-6523 www.truviewinspections.com luis@truviewinspections.com Inspected By: Luis Perez Home Inspection Report Prepared For: Unspecified Client Property Address: Sample

More information

Home Inspection. Happy Home Buyer 125 Happy Lane Anytown TN The date of the inspection

Home Inspection. Happy Home Buyer 125 Happy Lane Anytown TN The date of the inspection 7400 Hwy 11E Lenoir City, TN 37772 865-986-2516 Donnie Bentley TN Lic# 183 Home Inspection Anytown TN 37772 The date of the inspection Page 1 of 41 Table of Contents Definitions 2 General Information 2

More information

UP AND UP HOME INSPECTIONS

UP AND UP HOME INSPECTIONS UP AND UP HOME INSPECTIONS 2054627564 upanduphomeinspections@gmail.com https://upanduphomeinspections.com/ RESIDENTIAL REPORT 1234 Main St. Northport AL 35475 Buyer Name 05/03/2018 9:00AM Inspector Chris

More information

Inspection Report. Provided by: Cummins Services LLC. Inspector: Bill Cummins. Phone:

Inspection Report. Provided by: Cummins Services LLC. Inspector: Bill Cummins. Phone: Inspection Report Provided by: Cummins Services LLC Inspector: Bill Cummins Phone:814-599-5797 Email:cumminsservices01@gmail.com Property Address: 662 Ridgley Street Orbisonia, PA 17243 Table Of Contents:

More information

1623 Carol Street Downers Grove, Illinois Inspection Report for Property at: Private Home Inspection for:

1623 Carol Street Downers Grove, Illinois Inspection Report for Property at: Private Home Inspection for: 1623 Carol Street Downers Grove, Illinois 60515 Inspection Report for Property at: Private Home Inspection for: 1 This report presents the results of our inspection of the above referenced property performed

More information

Collier Home Inspections, LLC

Collier Home Inspections, LLC Cover Page Collier Home Inspections, LLC Property Inspection Report, 33912 Inspection prepared for: Report Sampe Agent: Ronald Monald - Collier Home Inspections, LLC Inspection Date: 8/19/2010 Time: 12:30

More information

SC Standards Of Practice for Home Inspectors

SC Standards Of Practice for Home Inspectors SC Standards Of Practice for Home Inspectors The following Standards provide guidelines for the Residential Home Inspector and outline what the Residential Home Inspector should observe, identify, inspect

More information

Woodard Inspections & Services, LLC

Woodard Inspections & Services, LLC Property Inspection Report Inspector: Kevin Woodard, Woodard Inspections & Services, LLC Cover Page 43000 Inspection prepared for: Jane Doe Real Estate Agent: Support - Home Inspector Pro Date of Inspection:

More information

Vallery Home Inspections, L.L.C.

Vallery Home Inspections, L.L.C. Cover Page Vallery Home Inspections, L.L.C. Property Inspection Report 500 JaneJohn Rd., Houston T Inspection prepared for:: John Doe & Jane Doe Real Estate Agent: William B. Johnson - Johnsons Realty

More information

Mr. Homeowner Mrs. Homeowner

Mr. Homeowner Mrs. Homeowner NATIONAL PROPERTY INSPECTIONS America's Premier Inspection Service Inspection Report Prepared on Behalf of: Mr. Homeowner Mrs. Homeowner Concerning Property Located at: 123 Any Street Keller, TX National

More information

Property Inspection Report

Property Inspection Report Property Inspection Report Report Number: 1386 For The Property Located On: Prepared For Exclusive Use By: Mrs. Beata Lorine Report Prepared By: Ric Scialabba; License No.: 3235 Inspector Signature: Date

More information

Report Page 1 of 23 12/30/2013 Tri-City Home Inspections James Eddy ID:

Report   Page 1 of 23 12/30/2013 Tri-City Home Inspections James Eddy ID: Page 1 of 23 Tri-City Home Inspections James Eddy ID: 10-10-12-718-11267 6855 W. Clearwater A101-296 Kennewick, WA 99336 Email: tchinspections@yahoo.com Phone: 509-551-5639 Web: www.tchinspections.com

More information

Inspection Connection

Inspection Connection Cover Page Property Inspection Report Inspection prepared for: Mickey Mouse Date of Inspection: 12/3/2014 Time: 10:00am Age of Home: 2009 Size: 5200 Weather: recent rain Inspector: License #H16106238-0511

More information

SNS Home Inspections LLC

SNS Home Inspections LLC Cover Page SNS Home Inspections LLC Property Inspection Report 12345 Inspection prepared for: Donald Duck Real Estate Agent: - Date of Inspection: 2/20/2015 Time: 9:00 AM Age of Home: 2009 Size: 3424 sq

More information