MAXIMA. Maxima Testing Data, Section Properties, and Load Tables
|
|
- Kelley Cole
- 5 years ago
- Views:
Transcription
1
2
3 MAXIMA Maxima Maxima Testing Data, Section Properties, and Load Tables For any available Testing Data, Section Properties, or Load Tables, please visit For additional information, please contact the McElroy Engineering Department at Maxima Panel Availabilty WIDT PAN CONDITIONS FACTORYNOTCING SEAM DOUBLE PENCIL RIB SINGLE PENCIL RIB WIDT IN INCES 90 DEGREE SEAM 180 DEGREE SEAM MINOR RIBS STRIATED CURVED FLAT PAN MAXIMA PROFILES LAP EAVE NONE MAXIMA1.5 SOWN AS STRIATED 12 MAXIMA1.5 SOWN AS STRIATED 16, 18 MAXIMA SOWN AS FLAT PAN (OPT.) 12 MAXIMA SOWN AS BEAD (PENCIL) RIB (OPT.) 16, 18 MAXIMA ADV SOWN AS STRIATED 12 MAXIMA ADV SOWN AS STRIATED MAXIMA SOWN AS MINOR RIB (STD.) 18, 24 1 MAXIMA & CAN BE FACTORY NOTCED AT EITER TE LAP END OR TE EAVE END, BUT NOT BOT ENDS OF TE PANEL. MAXIMA ADV IS ALSO AVAILABLE WITOUT SOULDERS.
4 MAXIMA Maxima Seaming Details Maxima Before Mechanical Seaming Maxima 90 Fold Maxima 1.5 Before Mechanical Seaming Maxima Fold Maxima ADV Before Mechanical Seaming Details: Maxima ADV 180 Fold - Mechanically seamed profile - Factory applied sealant (on non-curved panels only) - Factory formed eave notch upon request - Minimum slope: 1:12 for Minimum slope: 1/2:12 for - Minimum slope: 1/4:12 for - Can be installed over solid deck or open framing - Maxima and ADV also available jobsite formed for long lengths - Floating clips allow for 3 1/8 thermal movement - Oil canning is a natural occurrence in metal panels and is not a cause for panel rejection. Maxima ADV Without Shoulders Before Mechanical Seaming Maxima ADV Without Shoulders 180 Fold Panel Options: - Seam height: 1.5, & - Maxima: 90 degree seam - Maxima 1.5 and ADV: 180 degree seam - Panel width:, 1, 18, and 2 - Panel configurations: Maxima, Maxima 1.5 and ADV: flat, striated, pencil ribs, minor ribs ( only) Maxima 1.5 and ADV: curved - Coating: - Kynar 500 (PVDF) - Substrate: - Standard 24 GA Galvalume - Optional 22 GA Galvalume - Optional.032 and.040 aluminum No testing available on aluminum - Maxima aluminum is produced in Sunnyvale, TX 2 Notes: - Customers can rent mechanical seaming equipment directly from Developmenta Industries (DI). DI is the only McElroy approved seamer supplier. - Please contact a McElroy representative for specific pricing, lead times, special colors or gauges that may not be on a McElroy Metal color chart. - Contents in this manual are subject to change without notice. To confirm this book is the most current copy, please visit McElroy s website at
5 1.5 Maxima Eave Trim MLSE 2 1/8 MAXIMA 1.5 COMMERCIAL / INDUSTRIAL APPLICATIONS Sculptured Eave Trim MX / Valley Trim MXVF 3 1/8 1 3/ 1 3/ 1 1 Rake Trim MXRT Rake Tie-In Trim MXEW Rake Slide MLRS 3/ 2 3/8 1 3/ Rake End Cap ML-RE 9 3/1 26 Ga. igh Eave Trim MLS4 3 3/ 1 3/ 5 7/8 3/ 1.5 Zee Flashing MX1ZF Fixed igh Tie-In MXSW 1 1/ igh Eave Trim MLS / Floating igh Tie-In MXFSW 1 3/ 5 3/ ip Flashing MXF Floating ip Trim MXFF 5 3/ 5 3/ Fixed Ridge Trim MFXR / 3 specify roof pitch Indicates an open hem - All other hems are closed.
6 1.5 MAXIMA Floating Ridge Trim MFLR1 1 3/ MAXIMA 1.5 COMMERCIAL / INDUSTRIAL APPLICATIONS Fixed Peak Box MLFXPB1 1ʼ - Fixed Peak Box MLFXPB4h 1ʼ - 8 3/ 9 3/1 9 3/ 1ʼ - 1ʼ - Floating Peak Box MLFLPB1h Floating Peak Box MLFLPB4 Cinch Angle ML-CA 1ʼ - 2 7/1 2ʼ - 1ʼ -43/ 2ʼ - 2ʼ - 2ʼ - 26 Ga. Gutter Corner Box for Sculptured Eave MLSCB1 3 1/ i- Corner Box MLLCB 5 Outside Corner Box for Standard Gutter MLGCB1 26 Ga. (Right and Shown Left and Opposite) 26 Ga. 26 Ga. (Right and Shown (Right and Shown Left and Opposite) Left and Opposite) 1.5 Maxima Gutter MX1G1 1.5 Maxima Gutter MX1G4 Gutter Strap ML-GS 4 Snow guards required to prevent damage caused by sliding snow. specify roof pitch 7/8 7 5 Snow guards required to prevent damage caused by sliding snow. 7 7/8 3/ 3/ Indicates an open hem - All other hems are closed.
7 1.5 Maxima MAXIMA 1.5 COMMERCIAL / INDUSTRIAL APPLICATIONS Gutter End Cap MX2GEC2 4 7/1 Gutter End Cap Over 2:12 TO 4:12 Pitch MX2GEC4 4 Downspout BBPDS /1 7 1/1 7 3/8 4 11/1 3 15/1 14ʼ 26 Ga. 26 Ga. Aluminum Downspout Outlet Box BBPOUT Downspout Strap BBPDSS ʼ- x Downspout Elbow A-Style BBPELA Lock-Seam Downspout - Corner (Right and Corner Shown) Lock-Seam Downspout - Center Please specify left or right hand corner Lock-Seam Downspout Outlet - Standard 5 7/8 Lock-Seam Downspout Strap 4 1/ Notes: 5
8 & ADV Eave Trim MLSE 2 1/8 3 1/8 Rake Trim MXRT 1 3/ Rake End Cap ML-RE MAXIMA & ADV COMMERCIAL / INDUSTRIAL APPLICATIONS 1 3/ Sculptured Eave Trim to 4:12 pitch MX2SCE4 1 3/ Rake Tie-In Trim MXEW 2 3/8 Zee Flashing MX2ZF 1 1/ 2 3/ Valley Flashing MXVF Rake Slide MLRS 1 3/ igh Eave Trim MLS /1 1 7/8 26 Ga. 3/ 1 3/ igh Eave Trim MLS4 3 3/ 1 3/ 5 7/8 Fixed igh Tie-In MXSW Floating igh Tie-In MXFSW 1 3/ 5 3/ ip Trim MXF Floating ip Trim MXFF 5 3/ 5 3/ Fixed Ridge Trim MFXR / 6 specify roof pitch Indicates an open hem - All other hems are closed.
9 & ADV Floating Ridge Trim MFLR1 1 3/ 8 3/ Floating Peak Box MLFLPB1h MAXIMA & ADV COMMERCIAL / INDUSTRIAL APPLICATIONS Fixed Peak Box MLFXPB1 9 3/1 1ʼ - Floating Peak Box MLFLPB4 1ʼ - Fixed Peak Box MLFXPB4h 1ʼ - 9 3/ Cinch Angle ML-CA 1ʼ - 1ʼ - 2 7/1 2ʼ - 1ʼ - 2ʼ - 2ʼ - 2ʼ - Gutter Corner Box for Sculptured Eave MLSCB1 3 1/ i- Corner Box MLLCB 5 Outside Corner Box for Standard Gutter MLGCB1 26 Ga. (Right and Shown Left and Opposite) 26 Ga. 26 Ga. (Right and Shown (Right and Shown Left and Opposite) Left and Opposite) Maxima Gutter MX2G1 Maxima Gutter MX2G4 Gutter Strap ML-GS 7/8 7 1/ /8 3/ 3/ 7 Snow guards required to prevent damage caused by sliding snow. specify roof pitch Snow guards required to prevent damage caused by sliding snow. Indicates an open hem - All other hems are closed.
10 & ADV Gutter End Cap - Maxima MX2GEC2 4 7/1 MAXIMA & ADV COMMERCIAL / INDUSTRIAL APPLICATIONS Gutter End Cap Over 2:12 TO 4:12 Pitch MX2GEC4 4 Downspout BBPDS /1 4 11/1 7 1/1 3 15/1 7 3/8 14ʼ 26 Ga. 26 Ga. Aluminum Downspout Outlet Box BBPOUT Downspout Strap BBPDSS ʼ- x Downspout Elbow A-Style BBPELA Lock-Seam Downspout - Corner (Right and Corner Shown) Lock-Seam Downspout - Center Lock-Seam Downspout Outlet - Standard 5 7/8 Please specify left or right hand corner Lock-Seam Downspout Strap 4 1/ Notes: 8 specify roof pitch
11 Maxima Eave Trim MLSE 3 1/8 Rake Trim MXRT 2 1/8 1 3/ MAXIMA COMMERCIAL / INDUSTRIAL APPLICATIONS Sculptured Eave Trim to 4:12 pitch MLSCE / Rake Tie-In Trim MXEW 1 Valley Flashing MXVF Rake Slide MLRS 1 3/ 1 1 3/ 2 3/8 Rake End Cap ML-RE Zee Flashing MX3ZF 1 1/8 igh Eave Trim MLS /1 2 7/8 26 Ga. 3/ 1 3/ igh Eave Trim MLS4 5 7/8 3 3/ 1 3/ Fixed igh Tie-In MXSW Floating igh Tie-In MXFSW 1 3/ 5 3/ ip Flashing MXF Floating ip Flashing MXFF 5 3/ 5 3/ Fixed Ridge Flashing MFXR / 9 specify roof pitch Indicates an open hem - All other hems are closed.
12 MAXIMA Floating Ridge Flashing MFLR1 1 3/ 8 3/ MAXIMA COMMERCIAL / INDUSTRIAL APPLICATIONS Fixed Peak Box MLFXPB1 9 3/1 1ʼ - Fixed Peak Box MLFXPB4h 9 3/ 1ʼ - 1ʼ - 1ʼ - Floating Peak Box MLFLPB1h Floating Peak Box MLFLPB4 Cinch Angle ML-CA 2ʼ - 2ʼ - 1ʼ - 2 7/1 1ʼ - 2ʼ - 2ʼ - Gutter Corner Box for Sculptured Eave MLSCB1 3 1/ i- Corner Box MLLCB 5 Outside Corner Box for Standard Gutter MLGCB1 26 Ga. (Right and Shown Left and Opposite) 26 Ga. 26 Ga. (Right and Shown (Right and Shown Left and Opposite) Left and Opposite) Maxima Gutter MLG1 Maxima Gutter MLG4 Gutter Strap ML-GS 7/8 5 1/ 1 1/ 3/ 6 1/8 6 1/8 3/ 10 Snow guards required to prevent damage caused by sliding snow. specify roof pitch Snow guards required to prevent damage caused by sliding snow. Indicates an open hem - All other hems are closed.
13 Maxima Gutter End Cap MLGEC1 1 9/1 4 11/1 MAXIMA COMMERCIAL / INDUSTRIAL APPLICATIONS Gutter End Cap Over 2:12 TO 4:12 Pitch MLGEC4 2 3/1 5 5/1 Downspout BBPDS 6 1/1 6 1/1 14ʼ 26 Ga. 26 Ga. Aluminum Downspout Outlet Box BBPOUT Downspout Strap BBPDSS ʼ- x Downspout Elbow A-Style BBPELA Lock-Seam Downspout - Corner (Right and Corner Shown) Lock-Seam Downspout - Center Please specify left or right hand corner Lock-Seam Downspout Outlet - Standard 5 7/8 Lock-Seam Downspout Strap 4 1/ Notes: 11 specify roof pitch
14 1.5 Maxima Arch Eave Trim MXASE 4 3/8 Arch Valley Trim MXAVT Arch Rake Trim MXART 1.5 Arch Zee Flashing MX1ZF 1 1/ Arch ip Trim MXAF /8 MAXIMA 1.5 ARCITECTURAL APPLICATIONS 5 1/ Eave Drip/Rake Trim MXADE35 5 1/8 Arch Offset Cleat MXAOF / Arch Rake Tie-In Trim MXAEW 13/1 Arch Angle Trim MXAAT Arch igh Eave Trim MXAS / 3/8 Eave Drip/Rake Trim MXADE15 5 Arch Perimeter Cleat MXAPC 1 3/ Arch Utility Offset Cleat MXUOF / 3/ 1 3 Arch Ridge Trim MXARF 15 Arch igh Tie-In Trim MXASW 6 3/8 6 3/8 3/1 10ʼ 6 3/8 6 3/ / Arch Face Mounted Gutter MXAFMG Snow guards required to prevent damage caused by sliding snow. specify roof pitch 6 Arch Flanged Gutter MXAFLG 5 5 Snow guards required to prevent damage caused by sliding snow. Arch Gutter Strap MXAGS 10 0ʼ - 10 Indicates an open hem - All other hems are closed.
15 1.5 Maxima MAXIMA 1.5 ARCITECTURAL APPLICATIONS Arch Gutter End Cap MXAGEC 4 7/8 Aluminum Downspout Outlet Box BBPOUT Downspout BBPPS 4 15/1 26 Ga. (Left and Shown Right and Opposite) Downspout Strap BBPDSS 10 x Downspout Elbow A-Style BBPELA ʼ ʼ - TRIM & ADV Arch Eave Trim MXASE MAXIMA & ADV ARCITECTURAL APPLICATIONS 4 3/8 Eave Drip/Rake Trim MXADE35 5 1/8 Eave Drip/Rake Trim MXADE / 13 Arch Valley Trim MXAVT specify roof pitch 9 9 Arch Rake Trim MXART 5 1/8 5 1/ Arch Offset Cleat MXAOF Arch Rake Tie-In Trim MXAEW / 13/1 1 3/ Arch Utility Offset Cleat MXUOF 27 3/ / Arch Perimeter Cleat MXAPC 3/ 1 3/1 10ʼ Indicates an open hem - All other hems are closed. 15
16 & ADV Arch Zee Trim MX2ZF MAXIMA & ADV ARCITECTURAL APPLICATIONS 1 1/ Arch Angle Trim MXAAT Arch Ridge Trim MXARF 6 3/8 6 3/8 1 7/8 Arch ip Trim MXAF 6 3/8 6 3/8 Arch Gutter End Cap MXAGEC 4 7/8 Arch igh Trim MXAS 5 1/ Arch igh Tie-In Trim MXASW Ridge Flashing (Cor-A-Vent) Spacer Trim (Cor-A-Vent) Diverter Trim (Cor-A-Vent) 7 1/ 3/ 5 Snow guards required to prevent damage caused by sliding snow. x Downspout Elbow A-Style BBPELA 6 1 3/ 5 24 Ga. 24 Ga. 24 Ga. Arch Face Mounted Gutter Arch Flanged Gutter Arch Gutter Strap MXAFMG MXAFLG 5 MXAGS Snow guards required to prevent damage caused by sliding snow. 6 Downspout BBPPS ʼ / ʼ 26 Ga. (Left and Shown Right and Opposite) 8.5 Aluminum Downspout Outlet Box BBPOUT Downspout Strap BBPDSS specify roof pitch 10 14ʼ - Indicates an open hem - All other hems are closed.
17 ACCESSORIES MAXIMA Maxima 1.5 Low Floating Clip Item #: /8 2:16 and 2:18 Utility Fixed Clip Item #: :16 and 2:18 Low Fixed Clip Item #: /8 7/8 4 1/ 22 Ga. 7/8 3/3/ 3 1/ 22 Ga. 7/8 7/8 3/3/ 3 1/ 22 Ga. 2:16 and 2:18 igh Fixed Clip Item #: :16 and 2:18 Low Floating Clip Item #: /8 2:16 and 2:18 igh Floating Clip Item #: /8 3/3/ 7/8 3 1/ 22 Ga. 4 1/ 22 Ga. 4 1/ 22 Ga. 3:24 Utility Fixed Clip Item #: :24 Low Fixed Clip Item #: :24 igh Fixed Clip Item #: /8 7/8 7/8 3/3/ 3 1/ 7/8 7/8 3/3/ 7/8 3 1/ 7/8 3/3/ 3 1/ 22 Ga. 22 Ga. 22 Ga. 3:24 Low Floating Clip Item #: :24 igh Floating Clip Item #: Utility Eave Plate Item #: /8 15/1 1/8 4 1/ 22 Ga. 4 1/ 22 Ga. 16 Ga. Low Eave Plate Item #: /1 igh Eave Plate Item #: /1 Bearing Plate Item #: Galvanized Item #: Primed 5 3/8 1 3/ 16 Ga. 16 Ga. 2 3/1 2 3/1 16 Ga. Back- Plate 1 Item #: Item #: Item #: igh Floating Rake Plate Item #: /1 Low Floating Rake Plate Item #: /1 1ʼ 0 CTRʼS (TYP.) 1ʼ 0 CTRʼS (TYP.) Ga. 1 3/ 3/8 14 Ga. 14 Ga. Images not drawn to scale.
18 ACCESSORIES Maxima 1.5 Rake Support Angle Red Primed Low Floating x 10ʼ Item #: MAXIMA Maxima / ADV Rake Support Angle Red Primed Low Floating x 10ʼ Item #: Maxima / ADV Rake Support Angle Red Primed igh Floating x 10ʼ Item #: /8 3 1/8 1ʼ 0 O.C. 2 3/8 1ʼ 0 O.C /1 1ʼ 0 O.C. Maxima Rake Support Angle Red Primed igh Floating x 10ʼ Item #: Maxima Outside Universal Closure 1 (Part # varies by color) Maxima Outside Universal Closure 18 (Part # varies by color) 4 1/ 1 3/ 1ʼ 0 O.C Maxima Outside Closure 2 (Part # varies by color) Cinch Strap 1 (Part # varies by color) Cinch Strap 18 (Part # varies by color) 2 3:24 Cinch Strap 2 (Part # varies by color) 4ʼ Back- Channel - Galvanized Item #: / 6ʼ Back- Channel - Galvanized Item #: / 4ʼ 6ʼ Thermal Spacer 3/8 x 14 7/8 Item #: /8 x 16 7/8 Item #: /8 x 22 7/8 Item #: Thermal Spacer x 14 7/8 Item #: x 16 7/8 Item #: Thermal Spacer x 14 7/8 Item #: x 16 7/8 Item #: x 22 7/8 Item #: VARIES VARIES VARIES 3/8 zthermal Spacer x 14 7/8 Item #: x 16 7/8 Item #: VARIES 1/4-14 x 1 1/ TEK2 Self Driller W/O Washer - Plain Item #: #14 x Type A Item #: Images not drawn to scale.
19 ACCESSORIES MAXIMA #12-24 x 1 1/ TEK 4.5 W/O Washer - Plain Item #: /4-14 x 1 1/ Shoulder TEK2 3/8 W W/O Washer - Plain Item #: /4-14 x 1 1/ TEK2 ZAC (Part # varies by color.) 1/4-14 x 7/8 LAPTEK ZAC Self Driller (Part # varies by color.) #14-10 x Type A ZAC (Part # varies by color) 43D Pop rivets (Part # varies by color) #12-13 Dekfast Phillips (Length varies by application) #10-16 x TEK2 Pancake ead Self-Driller - Plain Item #: #10-12 x Type A Pancake ead Woodgrip - Plain Item #: Touch- Paint Pen (Part # Varies by ) Sikalastomer Butyl Sealant Item #: Titebond Caulk Sealant (Part # varies by color) Butyl Double Bead Tape Sealant 3/1 x 7/8 x 40ʼ Item #: Butyl Tape Sealant 3/3 x x 45ʼ Item #: Butyl Tape Sealant 3/3 x 3/8 x 45ʼ Item #: Strip Tape 3/ x x Item #: (Used with Maxima 324 Only) 17 Images not drawn to scale.
20
Panel / Trim /Accessories. Corporate Office 1500 Hamilton Rd. Bossier City, LA
Panel / Trim /Accessories Corporate Office 1500 amilton Rd. Bossier City, LA 71111 www.mcelroymetal.com MAXIMA Maxima Maxima Load Tables and Section Properties Load Tables and Section Properties for Maxima
More information238T and 138T Panel and Accessories Price List 9/29/2017 (price good for shipments through 11/31/2017) Customer Job Date Sales Rep 238T PANEL ITEM #
238T and 138T Panel and Accessories Price List 9/29/2017 (price good for shipments through 11/31/2017) Customer Job Date Sales Rep 238T PANEL ITEM # DESCRIPTION SELLING PRICE UOM 238T 238T Seam Cap 24
More informationMULTI-RIB/R-PANEL. R-Panel
MULTI-RIB/R-PANEL Multi-Rib 1.1875 1 Multi-Rib Roofs & Walls 1 ( With Purlin Bearing Leg ) 36 Cover Width R-Panel 1.25 R-Panel Roofs & Walls ( With Purlin Bearing Leg ) 36 Cover Width 1.1875 1 Multi-Rib
More information* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request.
is a concealed fastener architectural standing seam roof panel. The panels are easily installed over decking, utilizing metal clips. panels are ideally suited for decorative mansard, fascia and roofs.
More informationPanel / Trim /Accessories. Corporate Office 1500 Hamilton Rd. Bossier City, LA
Panel / Trim /Accessories Corporate Office 1500 Hamilton Rd. Bossier City, LA 71111 www.mcelroymetal.com MULTI-RIB/R-PANEL Multi-Rib 1.1875 1 Multi-Rib Roofs &Walls 1 ( With Purlin Bearing Leg ) 36 Cover
More informationTYPICAL ROOF CONDITION LAYOUT
FIXED POINTS TYPICAL ROOF CONDITION LAYOUT 15 17 9 16 29 12 14 11 3 7 35 20 6 23 30 31 24 13 18 Typical Roof Condition Layout... 1 Low Eave Isometric View - Fixed/ Floating... 2 Low Eave Section - Fixed/
More informationSHURLOC 150 STANDARD DETAILS
OVER WOOD DECK STANDARD DETAILS Austin - Headquarters/Sales Office 830 Sagebrush Drive Austin, TX 78758 (512) 452-1515 (800) 428-7412 Fax (512) 833-7499 www.ctmrs.com email: info@ctmrs.com Seguin - Plant/Sales
More informationTRIAD CORRUGATED METAL, INC.
TRIAD CORRUGATED METAL, INC. COMMERCIAL RESIDENTIAL AGRICULTURAL MS-216 MS-218 Panel Guide This guide describes the design and performance characteristics of the MS-216 and MS-218 Roof panel system. The
More informationTRIAD CORRUGATED METAL, INC.
TRIAD CORRUGATED METAL, INC. C O M M E R C I A L R E S I D E N T I A L A G R I C U L T U R A L Snap Loc Panel Guide Snap Loc metal panels are a perfect fit for residential, architectural and commercial
More informationTREMLOCK SL INSTALLATION MANUAL
TREMLOCK SL INSTALLATION MANUAL TREMLOCK SL TremLock SL i a concealed fatener architectural tanding eam roof panel. The TremLock SL panel are eaily intalled over decking, utilizing metal clip. TremLock
More informationCentral Texas Metal Roofing Supply Co., Inc 36" SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 40 ¼ 40 ¼ NET COVERAGE
3 4 " 9" 36" GAUGE PANEL FINISH 26 26 26 26 24 24 24 24 FRONTIER RIB LAP GUARD FRONTIER RIB LAP GUARD FRONTIER RIB LAP GUARD LAP GUARD LAP GUARD GALVALUME GALVALUME SMP SMP GALVALUME GALVALUME KYNAR500
More informationIMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE WEATHER GUARD PANEL.
IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE WEATHER GUARD PANEL. IF THERE IS A CONFLICT BETWEEN PROJECT ERECTION DRAWINGS PROVIDED OR APPROVED BY WHIRLWIND BUILDING
More informationNUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS
NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS Nucor VR16 II Vertical Rib Standing Seam Roof System...2 Nucor VR16 II Property and Span Tables...3 Standard Details...5 ED3010PE - Gutter...5
More information900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900
CS-PJ-01-900 CS-DS-01-900 CS-PJ-02-900 CS-EL-01-900 CS-EL-02-900 CS-EL-03-900 CS-EL-04-900 CS-RD-01-900 CS-RD-02-900 CS-RD-03-900 CS-EV-01A-900 CS-EV-01B-900 CS-EV-02A-900 CS-EV-02B-900 CS-EV-03A-900 CS-EV-03B-900
More informationINSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK
INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK A. 1. Using curb ribs as a guide, layout and mark roof openings on completed roof deck as outside curb
More informationCentral Texas Metal Roofing Supply Co., Inc 36" NET COVERAGE SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 40 ¼ 40 ¼
36" 1 2 " 6" GAUGE PANEL FINISH NET COVERAGE SHEET WIDTH WEIGHT PER SQ. 26 26 26 26 24 24 24 24 TEXAS RIB CHANNEL GUARD TEXAS RIB CHANNEL GUARD TEXAS RIB CHANNEL GUARD CHANNEL GUARD CHANNEL GUARD GALVALUME
More informationPBR & PBU PANELS. Technical/Installation Information
PBR & PBU PANELS Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE PANEL S. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS A MINIMUM
More informationS BI COM P ON E NT CA T ALOG
SBI METAL BUILDINGS & COMPONENTS S BI COM P ON E NT CA T ALOG Date: 03 / 16 / 2017 COMMERCIAL PRODUCTS Commercial Panels and Trim Cee, Zee, Eave Struts, Angle, Channel, and Clips Accessories FT 0 1 2 3
More informationCentral Texas Metal Roofing Supply Co., Inc NET COVERAGE SHEET WIDTH
1 2 " 1 24" GAUGE PANEL FINISH NET COVERAGE SHEET WIDTH WEIGHT PER SQ. 26 5 Vee GALVALUME 24 26 3/8 95.00 PRICE PER SQ. PRICE PER LINEAR FOOT PANEL PRICING: 1. Price per Square is based on 26 3/8 sheet
More information1.5 mechanical lock ml 150
1.5 mechanical lock ml 150 Strip Width Base Material Thickness Min Tensible Min Yield Coatings Max 16 Steel.0225 to.0336 in 52 - ksi 50 - ski Painted / Galvalume UL CONSTRUCTION NUMBERS: TGKX554 The Mechanical
More information1.5 mechanical lock ml 150
1.5 mechanical lock ml 150 Strip Width Base Material Thickness Min Tensible Min Yield Coatings Max 16 Steel.0225 to.0336 in 52 - ksi 50 - ski Painted / Galvalume UL CONSTRUCTION NUMBERS: TGKX554 The Mechanical
More informationTable of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5
Table of Contents Section Page Notes to Designer/User...................1-2 Map of Typical Roof Conditions..............3 Fastener Placement........................4 Fastener Selection.........................5
More informationCentral Seam Plus. Central-Loc
Central Seam Plus Central-Loc Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES 3" 3" " or 18" COVERAGE " or 18" COVERAGE Central Seam Plus Field seamed Central-Loc Snaps together
More informationCentral Texas Metal Roofing Supply Co., Inc SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼
GAUGE PANEL FINISH NET COVERAGE 26 26 26 26 U PBU U PBU GALVALUME GALVALUME SMP SMP (NOTE 1) SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ WEIGHT PER SQ. 95.00 95.00 95.00 95.00 24 24 24 24 24 24 U PBU U PBU U PBU GALVALUME
More informationResidential Pricing Guide
Guide TABLE OF CONTENTS Panels 5V Crimp Slimline 2 4 Accessories Flat Sheets Coils V-Groove Soffit Ridge Caps Roof Jacks Touch-up Paint Insulation Slimline Rib Cover Closure Strips Tube Sealant 6 6 7
More informationTABLE OF CONTENTS PRODUCT CATALOGUE fax OVERVIEW PBR 7.2 LONGSPAN ECONORIB
PRODUCT CATALOGUE www.metroll.us sales@fontana.metroll.com ph. 909.823.7663 fax 909.693.5153 TABLE OF CONTENTS OVERVIEW PBR Product Overview and Color Charts Panel Information and Trim 7.2 LONGSPAN ECONORIB
More informationMcElroy Metal, Inc. MAX-RIB MATRIX
McElroy Metal, Inc. MATRIX McElroy Content CONTENTS Max-Rib General Information P-1 Max-Rib Panel Pricing P-2 Matrix Panel General Information P-3 Matrix Custom Trim and Accessories P-4 Max-Rib Post Frame
More informationPrior to ordering and installing materials, all dimensions should be verified by field measurements.
Important Information The application and detail drawings in this manual are strictly for illustration purposes and may not be applicable to all building designs or product installations. All projects
More informationHORIZON-LOC EXPOSED FASTENER TRIMS
Horizon -Loc Horizon-Loc is available in 6ga AZ50 painted Galvalume and bare Galvalume. Central States uses either the CentralGuard or Kynar 500 /Hylar 5000 paint system on all painted metals. Bare (non-painted)
More informationPBR & PBU PANELS. Technical/Installation Information
PBR & PBU PANELS Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE Retro-R PANELS. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS
More informationSIDEWALL/ENDWALL STANDING SEAM TRIMS SIDEWALL/ENDWALL CROSS SECTION NTS SIDING OR OTHER WALL CLADDING, TYP LOW PROFILE FASTENER, TYP
CHIMNEY FLASHING CROSS SECTION 1. CHIMNEY FLASHING TRIM IS DESIGNED TO FLASH AROUND CHIMNEYS AND LARGE PENETRATIONS (E.G. SKYLIGHTS). CH1 AND CH7 ARE INTENDED FOR USE WITH MOST EXPOSED FASTENER AND STANDING
More information5V Crimp DESIGN/INSTALLATION INFORMATION
5V Crimp DESIGN/INSTALLATION INFORMATION IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE SYSTEM. METAL DEPOTS DETAILS MUST BE FOLLOWED AS A MINIMUM TO INSURE APPROPRIATE
More information1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights
1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights These 1 Exam Prep tabs are based on the 2012 Sheet Metal and Air Conditioning Contractors' National Association, Inc., seventh edition.
More information1.5 snap lock sl 150
1.5 snap lock sl 150 Strip Width Base Material Thickness Min Tensible Min Yield Coatings 12.00 to 24 Steel.0128 to.027 in 52 - ksi 50 - ski Painted / Galvalume UL CONSTRUCTION NUMBERS: TGKX301, tgkx342a,
More informationw w w. s a q u l i t y m e ta l s. c o m
san antonio branch 210 W. Peden San Antonio TX 78204 P. (210) 227-7276 F. (210) 227-0329 MCALLEN branch 2221 Austin Ave McAllen TX 78501 P. (956) 627-2966 F. (956) 627-0918 w w w. s a q u l i t y m e ta
More informationPIPE. Central Texas Largest Distributor. Structural Steel, Pipe and Metal Building Components
Central Texas Largest Distributor Structural Steel, Pipe and Metal Building Components PIPE Waco Location P.O. Box 154485 913 South Loop Dr. Waco Texas 76705 Local - 254-754-2611 Bryan Location 9401 E.
More informationFor Metal Roofing Systems Fascia, Mansards,& Soffits
HIGGINS STEEL ROOFING SERIES 2000 STANDING SEAM DETAIL MANUAL For Metal Roofing Systems Fascia, Mansards,& Soffits Wall Panels/Siding HIGGINS CONSTRUCTION & SUPPLY CO. 3801 U. S. 50 HILLSBORO, OHIO 45133
More informationRS32 Multi-Section Skylight System under/over seam clip double diverter
INSTALLATION INSTRUCTIONS RS32-x RS32 Multi-Section Skylight System under/over seam clip double diverter www.rnssales.com sales@rnssales.com 805.375.3980 Fax 805.375.3981 SKYLIGHT ACRYLIC skyline series
More information1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920
SECTION 07620 - FLASHING AND SHEET METAL PART 1 - GENERAL 1.01 DESCRIPTION A. Work included: Provide all flashing and sheet metal not specifically described in other Sections of these Specifications but
More informationSECTION METAL ROOF AND SOFFIT PANELS
Metal Panel Systems, Inc. 11506 Reading Road Cincinnati, Ohio 45241-2512 Telephone: 800-554-6126 or 513-554-6120 Fax: 513-554-6121 www.metalpanelsystems.com info@metalpanelsystems.com Specifications for
More informationa division of NCI Standing Seam Roof Systems
a division of NCI Standing Seam Roof Systems Building Benefits You Can Expect From A&S Materials Standing Seam roof panels weigh a relatively modest 11/2 pounds per square foot. When long life is required
More informationRS24-10 Single-Section Skylight System
INSTALLATION INSTRUCTIONS RS24-10 VERSION 1.100316 DATED: 10/03/16 RS24-10 Single-Section Skylight System under/over seam clip double diverter US Patent D750,282 www.rnssales.com sales@rnssales.com 805.375.3980
More information4. Standard Trim Profiles Includes: Flat Sheets & Die Formed Ridge Caps
Table of Contents 4. Standard Trim Profiles Includes: Flat Sheets & Die Formed Ridge Caps Page Mark Description Condition BASE TRIM 3 FBBTD Base Trim (Box) Standard 3 FBBTC Base Trim (Return Leg) Customer
More informationWESTERN RIB. Installation, Flashings & Shop Drawing Detail Guide.
WESTERN RIB Installation, Flashings & Shop Drawing Detail Guide 901 W. Watkins Street Phoenix, AZ 85007 Phone: (877) 787-5467 (855) 426-7836 Email: sales@cortenroofing.com sales@metalforroofing.com For
More informationMetal Building Roof Curbs
Metal Building Roof Curbs 54 years of excellence... www.thybar.com 129 Metal Building Roof Curbs Table of Contents General Information 131 Specifications 132-133 Layout 134-135 Assembly Instructions 136-137
More informationw w w. s a q u l i t y m e ta l s. c o m
san antonio branch 210 W. Peden San Antonio TX 78204 P. (210) 227-7276 F. (210) 227-0329 MCALLEN branch 2221 Austin Ave McAllen TX 78501 P. (956) 627-2966 F. (956) 627-0918 w w w. s a q u l i t y m e ta
More informationWestern States 7/8 Corrugated
Western States 7/8 Corrugated Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer / Installers..1 Fastener Placement and Selection.2-3 Key
More informationPanel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing
EXTERIOR BASE DETAIL (FLUSH) EXTERIOR BASE DETAIL (OVERHANG) Base Trim with Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint Sealant Marriage Bead to Vertical Panel Joint Above and Below Z Flashing
More informationML-150. w w w. s a q u l i t y m e ta l s. c o m. san antonio branch 210 W. Peden San Antonio TX P. (210) F.
ML-150 san antonio branch 210 W. Peden San Antonio TX 78204 P. (210) 227-7276 F. (210) 227-0329 MCALLEN branch 2221 Austin Ave McAllen TX 78501 P. (956) 627-2966 F. (956) 627-0918 w w w. s a q u l i t
More informationIMAGE II. Panel Information. Detail Conditions. Flashing Profiles. Accessory Profiles. Testing Information. Design/Installation Considerations PIM-1
Table of ontents Product Page No. Product Page No. Panel Information Profiles... PIM-2 Panel Overview...PIM-2 Flashing Profiles Eave...PIM-3 Extended Eave...PIM-3 leat...pim-3 Offset leat...pim-3 5K Gutter...PIM-3
More informationSL-16. Design/Installation Information
SL-16 Design/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE SL Series ROOFING SYSTEM. ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES
More informationR PANEL / PBR PANEL. Installation, Flashings & Shop Drawing Detail Guide.
R PANEL / PBR PANEL Installation, Flashings & Shop Drawing Detail Guide 901 W. Watkins Street Phoenix, AZ 85007 Phone: (877) 787-5467 (855) 426-7836 Email: sales@cortenroofing.com sales@metalforroofing.com
More informationLight-Metal Roof Edge, Raised
NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED
More informationFlat. Ribbed Striated and 1 ½ TCM-Lok Installation Manual
Flat Ribbed.748.941.472 15.75 1.248 Striated.748.472 14.75 1.5.248.941 www.tricountymetals.com 1 and 1 ½ TCM-Lok Installation Manual Table of Contents Important Notice/Safety/Storage/Tools...1 Roofing
More informationPROLOK EAVE PROLOK ROOFING PANEL ROOFING NAIL
EAVE ROOFING NOTE: ROOF PITCH IS REQUIRED FOR FABRICATION LOW SLOPE ADD SEALER TAPE ROOFING NAIL 2x4 SUB- 2x8 EAVE TRIM 1. Install the eave trim using roofing nails. 2. If sealer tape is being used, install
More informationCOMMERCIAL & INDUSTRIAL CI-CFR-INDEX SHEET INDEX CI-CFR-INDEX SHEET INDEX CI-CFR-INFO C & I DISCLAIMER
CI-CFR-INDEX SHEET INDEX CI-CFR-INFO C & I DISCLAIMER CI-CFR-LG LEGEND CI-CFR-JT-01 PANEL JOINT CI-CFR-JT-02 PANEL JOINT SEQUENCE CI-CFR-JT-03 PANEL JOINT LAYOUT CI-CFR-SQ-01 PANEL INSTALLATION SEQUENCE
More informationArchitectural Wall Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is
More information238T Aluminum Standing Seam Metal Roof System (SSMRS)
238T Aluminum Standing Seam Metal Roof System (SSMRS) Text in red are instructions to the specifier and should be deleted. Text in blue are choices that need to be made, with those not selected, deleted.
More informationStrongSeam SSFF1 Panel
StrongSeam SSFF1 Panel Installation Manual May 2016 12 TO 24 COVERAGE CLIP OFFSET STRIATED PANEL (2 STRIATION BEADS ON PANEL) 0.875 0.9375 26 ga. & 24 ga. UL90 #529 UL2218 Class IV/Impact UL790 Class A/Fire
More informationPrestige Series 12. Installation guide
Prestige Series 12 Installation guide PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS Section Page Notes to Designer/User.................... 2 Panel Options............................. 3 Panel Details..............................
More informationPBR & PBU Panels. Technical/Installation Information
PBR & PBU Panels Technical/Installation Information TABLE OF CONTENTS A. PBR Panel 1. General Description..................................................................... 2 2. Architect/Engineer Information............................................................
More informationSNAP-LOK 1 1/2 Installation Manual
Flat Ribbed.709.394.197 15.5.248 1.417 1.496 Striated www.tricountymetals.com SNAP-LOK 1 1/2 Installation Manual Table of Contents Important Notice/Safety/Storage/Tools...1 Roofing Anatomy/Side Trim...2
More informationStanding Seam Installation Guide
Standing Seam Installation Guide Table of Contents Important Information... 3 Handling Material... 3 Delivering Material... 4 Mechanical Unloading... 4 Design Considerations... 4 Fastener Selection...
More informationDETAIL MANUAL A COMPREHENSIVE GUIDE TO METAL ROOFING GULFLOKTM HIDDEN SCREW METAL ROOF SYSTEM
DETAIL MANUAL A COMPREHENSIVE GUIDE TO METAL ROOFING GULFLOKTM HIDDEN SCREW METAL ROOF SYSTEM Gulf Coast Standing Seam Roofing Panels Since 2004, Gulf Coast Supply and Manufacturing has been happy to offer
More informationCONTINUOUS VENTILATORS
CONTINUOUS VENTILATORS used on metal roofing systems roofs conform to high standards and specifications which have been developed, tested and proven over many years. They provide an excellent value for
More informationPro Lok Roof System Product Application Guide INDEX
Page 1 INDEX 1.0 General...4 1.1 Purpose of the Application Guide...4 1.2 Product Contract Type...5 A. Pro Lok Standard Roof System...5 B. Pro Lok Component Roof...5 1.3 Responsibilities of the Parties...6
More informationCONSTRUCTION DETAILS HANDBOOK
100 AMBOY AVENUE PERTH AMBOY, NJ 08861 TEL 73-86-8614 FAX 73-86-8865 www.englertinc.com CONSTRUCTION DETAILS HANDBOOK For METAL ROOFING SYSTEMS FASCIA, MANSARDS, & SOFFITS WALL PANELS/SIDING INTRODUCTION
More informationHANDBOOK OF CONSTRUCTION DETAILS
HANDBOOK OF CONSTRUCTION DETAILS ARCHITECTURAL PRODUCTS FOR THE BUILDING INDUSTRY 12" SSR, Decor-Flush 7, Amp Lok, Double Lock, GrandCurve, High Seam, Posi-Lock Soffit, Slim Seam 7, Snap-on-Batten, Snap-On-Seam,
More informationSuperior Structural Standing Seam Roof Systems
07 61 00/MBC BuyLine 3903 Superior Structural Standing Seam Roof Systems OUR PANELS MAKE THE difference www.mbci.com Superior Structural Standing Seam Roof Systems Illustrious Standing Seam Roof Systems
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification
More informationT-Rib Roofing System
T-Rib Roofing System Installation Manual 3449 Hempland Road Lancaster, PA 17601 (717) 397-2741 308 Alabama Blvd. Jackson, GA 30233 (770) 775-4484 World Wide Web: www.fabral.com E-Mail: fabinfo@fabral.com
More informationCS-100 Guide Specifications
MANUFACTURER CUSTOM-BILT METALS 1333 Corporate Drive, Suite 103 Irving, Texas 75038-2520 (800) 826-7813 or info@custombiltmetals.com www.custombiltmetals.com CS-100 Guide Specifications This Guide Specification
More informationKS SERIES - VERTICAL INSTALLATION
CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV
More informationFairfield Metal 9 Audrey Place, Fairfield, NJ Phone: SEALANT COUNTER FLASHING FASTENER RAKEWALL FLASHING
SEALANT COUNTER FLASHING RAKEWALL FLASHING TUBE SEALANT Z CLOSURE FLASHING RIVET TAPE SEALANT SEE OPTION 1 & 2 NAILER TUBE SEALANT TUBE SEALANT SIDING OPTION 1 TAPE SEALANT FASTNER SILL FLASHING RAKEWALL
More informationCentral Snap. Condition Details C SNAPDETAILS
Central Snap Condition Details D C SNAPDETAILS150612.2 The men and women at Central States Manufacturing, Inc. would like to welcome you. OUR MISSION Central States Manufacturing, Inc. is a 100% employee-owned
More information2120 SW Poma Drive; Palm City, Florida Phone Fax
2120 SW Poma Drive; Palm City, Florida 34990 772-223-4055 Phone 772-781-7492 Fax www.sunlastmetal.com sales@sunlastmetal.com IMPORTANT NOTICE READ THIS MANUAL COMPLETELY BEFORE BEGINNING INSTALLATION OF
More information2120 SW Poma Drive; Palm City, Florida Phone Fax
2120 SW Poma Drive; Palm City, Florida 34990 772-223-4055 Phone 772-781-7492 Fax www.sunlastmetal.com sales@sunlastmetal.com IMPORTANT NOTICE READ THIS MANUAL COMPLETELY BEFORE BEGINNING INSTALLATION OF
More informationInstallation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME. MATTERHORN Tile
Installation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME MATTERHORN Tile Watch detailed installation videos online at matterhornmetalroofing.com/tile-installation Table of Contents Accessories: Most
More informationDrexel Metals Inc. DMC 5V 26 Gauge min. Face-Fastening Metal Roof System over Plywood
Drexel Metals Inc. DMC 5V 26 Gauge min. Face-Fastening Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed
More informationLokSeam. Design/Installation Information. This booklet includes: Trims and Accessories Design and Installation Information
LokSeam Design/Installation Information This booklet includes: Trims and Accessories Design and Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION
More informationClassic Rib Roofing Panels DETAIL MANUAL
Metal Roofing Wholesalers Classic Rib Roofing Panels DETAIL MANUAL www.metalroofingwholesalers.com 1170 Topside Rd Louisville, TN 37777 The Classic Rib Roofing Panel Figure 1 House With Classic Rib Metal
More informationDL-200. Specifications
DL-200 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Structural Preformed Metal Roofing PART 1: GENERAL 1.01
More informationAddendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE
SECTION 13 34 00 METAL SHADE STRUCTURE PART 1 - GENERAL 1.01 STRUCTURE TYPE A. Structure shall be free standing rigid frame and gable roof with slopes as indicated. Structure shall also include foundation,
More informationUNA-CLAD Metal Roofing Systems Application Guide
UNA-CLAD Metal Roofing Systems Application Guide UC-3 Double-Lock Architectural Series UC-4 No-Clip Architectural Series UC-6 Double-Lock Structural Series UC-14 Snap-Lock Standing Seam Series October
More informationUNA-CLAD Metal Roofing Systems Application Guide
UNA-CLAD Metal Roofing Systems Application Guide UC-3 Double-Lock Architectural Series UC-4 No-Clip Architectural Series UC-6 Double-Lock Structural Series UC-14 Snap-Lock Standing Seam Series March 22,
More informationRoofing Installation Manual: Concealed Fastener Panels Material Data, Trim Details, and Step-by-Step Instructions
Roofing Installation Manual: Concealed Fastener Panels Material Data, Trim Details, and Step-by-Step Instructions 1974 Livengood Ave Fairbanks, AK 99701 907-479-6002 allsteel.info@gmail.com Roof Installation
More informationSECTION STANDING-SEAM METAL ROOF PANEL
SECTION 074113 -STANDING-SEAM METAL ROOF PANEL PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationSSL-175. Specifications
SSL-175 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Preformed Metal Roofing PART 1: GENERAL 1.01 SECTION INCLUDES
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used
More informationRetro-R DESIGN/INSTALLATION INFORMATION
Retro-R DESIGN/INSTALLATION INFORMATION IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE Retro-R PANELS. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS A MINIMUM TO
More informationTATA BLUESCOPE STEEL LIMITED PRODUCT SPECIFICATION LANGUAGE FOR PRE ENGINEERED STEEL BUILDING (BUTLER BUILDING SYSTEM- WITH MR-24 ROOF SYSTEM)
Section 1: General Product specification Language Item language Item No. Description EX. Works Supply Price Freight Erection Taxes & Duties Total Amount Item 1 Structural Members Supply of BUTLER Building
More informationCovering Design Regions
Covering Covering Design Regions Roof Covering Roof Covering (SSR) 24 coverage w/ 3 seam height Machine seamed, in-place Attached to roof secondary (purlins, widebay truss purlin or bar joist) w/ a concealed
More informationCATALOG 2017 METAL ROOF & WALL SYSTEMS
CATALOG 2017 METAL ROOF & WALL SYSTEMS Table Of Contents Thomas E. McElroy Sr. (Mr. Mac) in 1963 posing with the company s first rollformer. From humble beginnings in 1963, McElroy Metal has grown into
More informationcomponents your source. exceptional service
components your source. exceptional service VP Components, established in 1998, serves customers across North America by providing building components and accessories designed to meet the needs of the
More informationEVERSEAM 20 APPLICATION GUIDE
EVERSEAM 20 APPLICATION GUIDE Panel Overview Our Name Says It All!"#$%#&'()*+,!"#$%#&'(-.( Applications: The EverSeam panel is an architectural panel that is ideal for residential and light commercial
More informationSpecifications for FL-100 Soffit Panel
Union Corrugating Company Specifications for FL-100 Soffit Panel SECTION 07410 METAL SOFFIT PANELS PART 1 GENERAL 1.1 DESCRIPTON A. Section Includes: 1. Preformed metal soffit panel system 2. Associated
More informationwww.nucorbuildingsystems.com NBS - THE BRAND OF CHOICE Nucor CFR Roof Systems Foundation of Performance... 1... 2 Application and Guidelines... 3 Clip & Insulation Options... 4... 6 Warranties... 8 Details...
More informationVP ROOF SYSTEMS SSR ROOF SYSTEM. WEATHERTIGHT PERFORMANCE FOR low-slope ROOF APPLICATIONS
VP ROOF SYSTEMS style SSR ROOF SYSTEM INTERLOCKING PANELS provide LONG TERM WEATHERTIGHT PERFORMANCE FOR low-slope ROOF APPLICATIONS 3 high ribs and 24 panel width allow for positive water drainage Available
More informationSECTION STANDING SEAM METAL ROOFING
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 41 13 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Use for roofing sloped 1 in 4 (3 in/ft) or greater. 3. Delete between // // if not applicable
More informationNuRoof Retrofit Systems. Technical/Installation Information
Retrofit Systems Technical/Installation Information INTRODUCTION If your roof is causing problems due to leaks, high maintenance costs and low energy efficiency, the MBCI NuRoof Retrofit System is the
More information